Table of Contents 15 sections ™ COMMERCIAL 4/2 · BLUE · Single Stage / Multi-Stage / Heat Pump · ACCURACY OPTIMUM COMFORT AND PERFORMANCE · … ShowHide
Page 1 of the Emerson 1F95-0680 user manual — Exclusive Blue ™ Commercial Features
Page 1 · click to enlarge
Page 1

™ COMMERCIAL 4/2

BLUE

Single Stage / Multi-Stage / Heat Pump

ACCURACY OPTIMUM COMFORT AND PERFORMANCE

Programmable (7 Day, 5/1/1 Day) or Non-Programmable

Economizer / Damper Control Output

Emerson 1F95-0680 — ACCURACY OPTIMUM COMFORT AND PERFORMANCE diagram (page 1)
Fig. 1

Hardwired or Battery Powered with Optional Power Stealing Assist

1F95-1280

Universal Application 4 Heat / 2 Cool

Keypad lockout – total or partial

Dual fuel with outdoor sensor (F145-1378) or by logic program

Emerson 1F95-0680 — Universal Application 4 Heat / 2 Cool diagram (page 1)
Fig. 2 · Universal Application 4 Heat / 2 Cool

1F95-0680

Universal Application 4 Heat / 2 Cool

Lock feature secures thermostat to subbase, reduces tampering

Dual fuel with outdoor sensor (F145-1378)

5-Year Warranty

Commercial Control. Customer Comfort. Emerson® Big Blue™ Commercial and Emerson® Blue™ Commercial Thermostats from White-Rodgers are designed specifically for commercial applications, delivering a new level of comfort, control and security to your customers.

Exclusive Blue ™ Commercial Features

Standard Blue ™ Features

  • Pre-occupancy purge and/or programmable fan
  • Limited temperature range – energy-saving feature
  • Economizer/damper control output
  • Large, 12-square-inch or 6-square-inch display with backlight
  • Remote sensing indoor and at the thermostat
  • Exclusive Cool Savings ™ feature saves energy during peak A/C demand periods
  • Keypad lockout – total or partial
  • Automatic daylight savings option

12-square-inch touchscreen display · 6-square-inch display

Page 2 of the Emerson 1F95-0680 user manual — www.emerson.com
Page 2 · click to enlarge
Page 2

BLUE

™ COMMERCIAL 4/2

1F95-1280 / 1F95-0680

Universal Application

4 Heat / 2 Cool

Single Stage / Multi-Stage / Heat Pump

Programming Universal – installer selectable system applications Choice of 7 day, 5/1/1 day programmable or non-programmable (installer selectable) 2 time and 2 temperature settings (1 setback) – 1F95-1280 Choice of 4 time and 4 temperature settings per program (2 setbacks) or 2 time and 2 temperature settings (1 setback) – 1F95-0680 Energy savings up to 33% Patented pre-programmed schedule simplifies time and temperature programming

Performance Choice of battery-powered with optional power stealing assist or hardwired with battery backup Selectable Energy Management Recovery Meets California Building Code, Title 24 Fast (FA) or slow (SL) heating cycle anticipation Exclusive “Call for Service” diagnostic indicator Compressor lockout protection Millivolt compatible Electric heat option

Flexible temporary temperature override will override program for four (default) hours – 1F95-1280 Temporary temperature override will override program for two hours – 1F95-0680 Auto heat/cool changeover option – automatically switches between heating and cooling programs Heating and cooling, heating only or cooling only configuration (installer selectable) Setpoint temperature “limited range” capable Enhanced locking security reduces tampering – 1F95-0680 Furnace filter change reminder Maintains room temperature to within +/- 1˚F Room temperature display can be recalibrated up to +/- 4˚F

Comfort & Convenience Intuitive menu-driven setup, programming and operation, with audio prompt to confirm entries Permanent program retention during power loss Indefinite setpoint Hold or temporary temperature override

Display Large, 12-square-inch touchscreen display – 1F95-1280 Large, 6-square-inch display – 1F95-0680 Blue, lighted display for easier low-light viewing Larger, easy-to-read character size Large keys for easy operation

Terminal Designations* Terminal Block Wire Connection – 1F95-1280 Terminal Block Wire Connection – 1F95-0680

RC RH W2 Y W/E O/B Y2 G 6 L + S – C A1 RC RH W2 Y W/E O/B Y2 G L A1 + S – C 6

*See installation instructions or www.white-rodgers.com for terminal descriptions

Dimensions 4.6"H x 5.9"W x 1.2"D – 1F95-1280 4.2"H x 6.4"W x 1.7"D – 1F95-0680

Electrical Specifications Rating Battery Power: mV to 30 VAC, NEC Class II, 50/60 Hz or DC Input Hardwire: 20 to 30 VAC 1.5 Amps (load per terminal) 2.5 Amps maximum load (all terminals combined) Standard Systems Single Stage gas, oil, electric Single Stage heat pump Millivolt systems Multi-Stage gas, oil, electric Multi-Stage heat pump

Accessories Indoor Remote Sensor▼ F145-1328 Outdoor Remote Sensor▼ F145-1378 Thermostat Guards Clear – F29-0198 Metal – F29-0220 (solid base) Wallplates F61-2600 (8.1"W x 5.4H") F61-2634 (6.5"W x 5"H)

Thermal Specifications Setpoint Temperature Range: 45˚ to 99˚F (7˚ to 37˚C) Rated Differential: Heat 0.6˚F; Cool 1.2˚F Operating Ambient Temperature: 32˚ to 105˚F (0˚ to 41˚C) Operating Humidity Range: 90% non-condensing maximum Shipping Temperature Range: -40˚ to 150˚F (-40˚ to 65˚C)

For Additional Information Visit www.white-rodgers.com

Single StageMultiStageHeat PumpProgramsApplicationsSelectable Performance FeaturesComfort and Convenience Features Stages Heat/Cool by System for 1F95-1280 and 1F95-0680Program OptionsGas/Oil/Electric3 Wire ZoneMillivoltPower SourceAuto ChangeoverProgrammable FanEnergy Mgt. RecoveryDual Fuel Option*Keypad LockoutIndoor ▼ Remote SensorOutdoor ▼ Remote SensorLighted Display***Audible Feedback Cool Savings™Daylight Savings AdjustmentIgnition Module ResetPermanent Memory 1/12/24/27, 5+1+1, Ø✓✓✓H,B/PA✓✓✓✓✓✓✓✓✓ ✓✓✓✓

B =Battery, H =Hardwired, PA =Power Stealing Assist *Outdoor Sensor F145-1378 Required for 1F95-0680 ***Optional Continuous Display Light w/Hardwire Connection

▼ Only One (1) Remote Sensor May Be Used – Either Indoor or Outdoor; or Logic Program and Indoor Remote Sensor

St. Louis, Missouri Markham, Ontario

314-553-3600 905-948-3411 www.white-rodgers.com

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

www.emerson.com

WR-4495A

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Emerson 1F95-0680

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson 1F95-0680

Be the first to ask — other owners or our team will answer.

Original document

Emerson 1F95-0680 manual PDF

2 pages·157 KB·Thermostat·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…