Instruction/ maintenance manual of the product 1F82-261 Emerson
Go to page of 8
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
2 INST ALLA TION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall.
3 L R E 24 VAC 120 VAC Hot SYSTEM MONITOR SWITCH Neutral THERMOSTAT SYSTEM G W2 Figure 2. Typical wiring diagram for single transformer systems TRANSFORMER (Class II Current Limited) Changeover Relay*.
4 2 1 3 4 5 6 7 8 11 14 16 12 15 11 10 13 13 9 9 Figure 5. Thermostat display, buttons, and switches SU EMER HOLD PM SA MALF FLTR AM MO TU WE TH FR TIME PRGM RUN HOLD Fltr FAN EMER ON AUTO COOL OFF HE.
5 Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
6 WEEKDAYS (5 Day) SATURDAY (1 Day) Start Time Temp Start Time Temp 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating/Cooling Schedule Plan (Factory Program) Period 6:00 AM 8:00 AM 5:00 PM 10:00 PM 6:00 .
7 Use the table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs. Entering Your Program Set Current Time and Day 1. Press TIME button once. The display will show the hour only.
TROUBLESHOO TING Symptom P ossible Cause Corrective Action No Hea No Hea No Hea No Hea No Hea t/No Cool/No F t/No Cool/No F t/No Cool/No F t/No Cool/No F t/No Cool/No F an an an an an 1. Blo wn fuse or tripped circuit breaker . Replace fuse or reset breaker .
An important point after buying a device Emerson 1F82-261 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson 1F82-261 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson 1F82-261 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson 1F82-261 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson 1F82-261 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson 1F82-261, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson 1F82-261.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson 1F82-261. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson 1F82-261 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center