Getting Started Guide
060208-10, Rev. C June 2007

Lithium Batteries Caution. There is a danger of explosion if the Lithium battery in your chassis is incorrectly replaced. Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows:
Return the module with the Lithium battery to Alcatel-Lucent. The Lithium battery will be replaced at Alcatel-Lucent’s factory.
The features and specifications described in this guide are subject to change without notice.
Copyright © 2007 by Alcatel-Lucent. All rights reserved. This document may not be reproduced in whole or in part without the express written permission of Alcatel-Lucent.
Alcatel-Lucent® and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. Xylan®, OmniSwitch®, OmniStack®, and Alcatel-Lucent OmniVista® are registered trademarks of Alcatel-Lucent.
OmniAccess™, Omni Switch/Router™, PolicyView™, RouterView™, SwitchManager™, VoiceView™, WebView™, X-Cell™, X-Vision™, and the Xylan logo are trademarks of Alcatel-Lucent.
This OmniSwitch product contains components which may be covered by one or more of the following U.S. Patents:
Alcatel-Lucent 26801 West Agoura Road Calabasas, CA 91301 (818) 880-3500 FAX (818) 880-3505


The OmniSwitch 6850 Series is an advanced fixed configuration family of Ethernet switches. These switches provide wire rate Layer 2 forwarding and Layer 3 routing with advanced services.
OmniSwitch 6850-24L OK PRI PWR BPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 23 22 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
They are fixed configuration, triple-speed (10/100/1000) switches that provide increased network performance, improved application response times, secure the LAN, and enhance user productivity by maximizing mobility, network capacity, and services over existing category 5/5E/6 cabling.
OmniSwitch 6850-48L OK PRI PWR BPS
OmniSwitch 6850-P24L OK PRI PWR BPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
CLASS 1 LASER PRODUCT 1 2 3 4
CLASS 1 LASER PRODUCT
24 23 22 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
OmniSwitch 6850-P48L OK PRI PWR BPS
CLASS 1 LASER PRODUCT 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 3 5 7 9 11 13 15 17 19 21 25
10 12 14 16 18 20 22 24 2 4 6 8
Refer to the User Manual CD for additional hardware and software OmniSwitch documentation.
OK PRI PWR BPS
CLASS 1 LASER PRODUCT
OmniSwitch 6850-24 OK PRI PWR BPS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
OmniSwitch 6850-48 OK PRI PWR BPS
CLASS 1 LASER PRODUCT 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 23 22 21
OK PRI PWR BPS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CLASS 1 LASER PRODUCT
OK PRI PWR BPS
USB
CLASS 1 LASER PRODUCT
OK PRI PWR BPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 23 22 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
OmniSwitch 6850-P48 OK PRI PWR BPS
CLASS 1 LASER PRODUCT 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 23 22 21
OK PRI PWR BPS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CLASS 1 LASER PRODUCT
USB
OK PRI PWR BPS
CLASS 1 LASER PRODUCT
June 2007 OmniSwitch 6850 Series 1

directory architecture, image rollback protections, authenticated switch access, managing switch files, system configuration, using SNMP, and using web management software (WebView).
The following are the titles and descriptions of all the OmniSwitch 6850 Series user documentation included in the User Manual CD:
Includes network configuration procedures and descriptive information on all the major software features and protocols included in the base software package. Chapters cover Layer 2 information (Ether- net and VLAN configuration), Layer 3 information (static routes), security options (authenticated VLANs), Quality of Service (QoS), and link aggregation.
Describes the hardware and software procedures for getting an OmniSwitch 6850 Series switch up and running. Also provides information on fundamental aspects of OmniSwitch hardware components and software architecture.
Complete technical specifications and procedures for all OmniSwitch 6850 Series hardware, including chassis, power supplies, fans, combo ports, stacking procedures, optional backup power supplies, etc.
Includes network configuration procedures and descriptive information on all the software features and protocols included in the advanced routing software package. Chapters cover multicast routing (DVMRP and PIM-SM) and OSPF.
Complete reference to all CLI commands supported on the OmniSwitch 6850 Series. Includes syntax definitions, default values, examples, usage guidelines, and CLI-to-MIB variable mappings.
Includes information on Small Form Factor Pluggable (SFPs) and 10 Gbps Small Form Factor Pluggables (XFPs) transceivers.
Includes procedures for readying a switch for integration into a network. Topics include the software
2 OmniSwitch 6850 Series June 2007

In addition to the materials and components provided in the OmniSwitch 6850 Series shipment, you must provide the following items in order to complete this installation:
OmniSwitch 6850 Series switches have the following general electrical requirements:
Environmental Requirements
The following notes and warnings apply to all NEBS compliant platforms.
OmniSwitch 6850 Series switches have the following environ- mental and airflow requirements:
Grounding requirements: To ground the equipment prop- erly, connect a Panduit Corporation UL listed Lug, P/N: LCD8-10AL to the two threaded holes located on the rear of each chassis and power supply module. All connections should be made using 8AWG copper conductors.
(GR-1089 requires treatment of ground connections and painted surfaces as needed during installation.)
June 2007 Installing the Hardware 3

All surfaces that are used for intentionally grounding the EUT shall be brought to a bright finish and an anti oxidant solution must be applied to the surfaces being joined.
A single OS6850 weighs approximately 14 lbs (6.24 Kgs). A stack of eight OS6850 switches weighs approximately 112 lbs (50 Kgs).
Non-conductive coatings (such as lacquer and enamel) must be removed from threads and other contact surfaces to assure electrical conductivity.
(Thread forming screws with paint piercing washers may be used for this purpose during installation)
4 Installing the Hardware June 2007

Unpacking and Initial Setup
Your OmniSwitch 6850 Series switch order includes the following items:
To protect your OmniSwitch chassis and hardware compo- nents from electrostatic discharge (ESD) and physical damage, read all unpacking recommendations and instructions care- fully before beginning.
Depending on the items ordered for your specific network requirements, the following optional items may also be included:
1 Carefully cut the tape along the seam at the top of the box containing the chassis.
2 Lift the box’s top flaps. Remove any smaller boxes or pouches that are enclosed and set them aside.
3 Lift the chassis out of the packaging.
June 2007 Installing the Hardware 5
Recommendations · Instructions

4 Carefully remove any foam pads and protective plastic from the switch chassis.
Be sure that your switch is placed in a well-ventilated, static- free environment. Always allow adequate clearance at the front, rear, and sides of the switch.
5 If you are installing multiple switches in a stacked configuration, repeat steps 1 through 4 for the remaining switches that will make up the stack.
The following diagram shows recommended minimum clear- ances for adequate chassis airflow and access to components at the rear of the chassis:
6 Once all OmniSwitch 6850 Series switches have been removed from their packaging, continue to “Setting Up the Switch.”

Rear. 5 inches minimum at rear of chassis.
Sides. 2 inches minimum at left and right sides for chassis airflow.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Front. 6 inches minimum at front of chassis for cable access and LED visibility.
6 Installing the Hardware June 2007
Airflow Considerations · Chassis Top View

Never obstruct the air vents located at the left and right sides of the chassis.
To install the switch as a tabletop unit, follow the steps below:
1 Position the chassis on the table or bench where it is to be installed.
There are two ways in which the OmniSwitch 6850 Series switches can be installed:
2 Be sure that adequate clearance has been provided for chassis airflow and access to the front, back, and sides of the switch. For recommended clearances, refer to page 6. Also, be sure that you have placed the chassis within reach of all required AC power sources.
For information on setting up a switch as a tabletop unit, refer to “Installing the Switch on a Tabletop or Bench.” For infor- mation on rack-mounting the switch, refer to “Rack-Mounting the Switch” on page 8.
If you are placing multiple switches in a stacked configu- ration, carefully stack the remaining switches, one on top of the other. Up to eight switches may be stacked to form a single virtual chassis. Be sure to maintain adequate clearance at the front, rear, left, and right side of all switches (see page 6). Also, be sure that you have placed all switches in the stack within reach of required AC power sources.
OmniSwitch 6850 Series switches can be installed freestand- ing as tabletop units. Place your switch on a stable, flat, and static-free surface.
June 2007 Installing the Hardware 7
Tabletop Mounting Steps

Refer to the important guidelines below before installing the OmniSwitch chassis in a rack.
To rack-mount the switch, follow the steps below:
1 Align the holes in the provided rack-mount flanges with the four threaded holes in the OmniSwitch chassis. These threaded holes are located in the left and right sides of the chassis, near the front panel.
2 Attach the flanges to the chassis using the provided Phillips-head screws. Be sure to tighten each of the screws firmly using a Phillips screwdriver.
Attaching a Rack-Mount Flange
8 Installing the Hardware June 2007
Rack Mounting Steps · 46 Console

3 After the rack-mount flanges are secured to the chas- sis, mark the holes on the rack where the switch is to be installed.
7 Once the screws at the bottom of each flange are secure, install the remaining two rack-mount screws. Be sure that all screws are securely tightened.
4 Lift and position the switch until the rack-mount flanges are flush with the rack post.
8 If you are installing multiple switches in a rack to form a stacked configuration, repeat steps 1 through 7 for all switches in the stack.
5 Align the holes in the flanges with the rack holes that were marked in step 3.
6 Once the holes are aligned, insert a rack-mount screw (not provided) through the bottom hole of each flange. Tighten both screws until they are secure.

June 2007 Installing the Hardware 9

Installing Backup Power Supply Components
OmniSwitch 6850 Series switches offer Gigabit Ethernet combo ports, located on the front panel. These combo ports support hot-swappable fiber Small Form-Factor Pluggables (SFPs). For instructions on installing and removing combo port SFPs, refer to the instruction card provided with the SFP product.
For detailed information on installing backup power supply components—including the backup power supply, connector cables, and power cords—refer to the OmniSwitch 6850 Series Hardware Users Guide.
For information on connecting stacked switches, refer to the OmniSwitch 6850 Series Hardware Users Guide.
10 Installing the Hardware June 2007

Once your switch is properly set up and all the required hard- ware components are installed, you should connect all network and management cables required for your network applica- tions. Connections may include:
The default settings for the serial connection are as follows:
data bits (word size) 8
The console port, located on the chassis front panel, provides a serial connection to the switch and is required when logging into the switch for the first time. By default, this RJ-45 connector provides a DTE console connection.
June 2007 Connections and Cabling 11
baud rate 9600 · parity none · stop bits 1

LED States for a Standalone Switch
The OmniSwitch 6850 Series switch does not use an on/off switch. The power cord is the switch’s only connect/discon- nect device. The power connector socket is located on the switch’s rear panel. For more information, refer to the OmniSwitch 6850 Series Hardware Users Guide.
BPS Solid amber, if BPS attached is failed; off, if no operational BPS is attached; solid green if an operational BPS is attached and operating normally.
XFP1 Off (applies to all OmniSwitch 6850 Series switches except for the OmniSwitch 6850-24X, OmniSwitch 6850-P24X, OmniSwitch 6850-48X, OmniSwitch 6850-P48X, and OmniSwitch 6850-U24X).
To boot the switch, plug the power cord (provided) into the power connector socket at the switch’s rear panel. Next, plug the power cord into an easily-accessible power source, such as a grounded AC outlet or an Uninterruptible Power Supply (UPS).
The switch immediately begins the boot process. Allow a few moments for the switch to boot completely, then verify the status of all LEDs on the switch’s front panel. A successful boot for a standalone switch displays the following LED states:
XFP2 Off (applies to all OmniSwitch 6850 Series switches except for the OmniSwitch 6850-24X, OmniSwitch 6850-P24X, OmniSwitch 6850-48X, OmniSwitch 6850-P48X, and OmniSwitch 6850-U24X).
LED States for a Standalone Switch
Slot Indicator 1–8 (non-blinking), depending on the slot number value in the boot.slot.cfg file. See the OmniSwitch 6850 Series Hardware Users Guide for detailed information. The default value is 1.
12 Booting OmniSwitch 6850 Series Switches June 2007
OK Solid green · PRI Solid green · PWR Solid green

If any of the LED state differs from the states shown in the table above, refer to the OmniSwitch 6850 Series Hardware Users Guide for more information. Contact Alcatel-Lucent Customer Support if the unexpected LED state persists.
For information on booting stacked configurations and dynamic slot numbering, refer to the OmniSwitch 6850 Series Hardware Users Guide.
June 2007 Booting OmniSwitch 6850 Series Switches 13

Once the switch or stack has successfully booted and you have accessed your computer’s terminal emulation software via the console port, you are ready to log in to the switch’s Command Line Interface (CLI) and configure basic information. Complete the following steps during your first login session:
When you first log in to the switch or stack, you will be prompted for a login (i.e., user) name and password. During this first login session, only one user name option and one password option is available:
To log in to the switch or stack, enter admin at the login prompt:
Next, enter the factory default password, switch, at the pass- word prompt:
14 Your First Login Session June 2007

The default welcome banner, which includes information such as the current software version and system date, displays— followed by the CLI command prompt:
Assigning an IP address to your OmniSwitch 6850 Series switch is an important step in the setup process.
Welcome to the Alcatel-Lucent OmniSwitch 6850 Series Software Version 6.1.5.281.R01 Development, March 16, 2007.
Copyright(c), 1994-2007 Alcatel-Lucent All Rights reserved.
Remote sessions such as Telnet, FTP, and WebView require an IP address. The IP address for these session types serves as a destination point for the remote session. Therefore, before the switch can support any remote login sessions, a valid IP address must be configured.
OmniSwitch(TM) is a trademark of Alcatel-Lucent registered in the United States Patent and Trademark Office.
More Information on User Accounts. A user account includes a login name, password, and user privileges. Privileges determine whether the user has read or write access to the switch and which commands the user is authorized to execute.
To assign an IP address to a switch, simply assign an IP address to the switch’s default VLAN 1 by entering the ip interface command at the CLI prompt. Be sure that the command begins with the command syntax:
For detailed information on setting up and modifying user accounts and user privileges, refer to the “Managing Switch User Accounts” chapter of your OmniSwitch 6800/ 6850/9000 Switch Management Guide.
-> ip interface address
exactly as shown, followed by the IP address. For example:
-> ip interface vlan_1 address 172.2.120.1 vlan 1
For information on assigning IP addresses in a stacked configuration, refer to the OmniSwitch 6850 Hardware Users Guide.
June 2007 Your First Login Session 15
->

Unlocking Specified Session Types
Security is a key feature on OmniSwitch 6850 Series switches. As a result, when you access the switch for the first time, you must use a direct console port connection. All other session types (Telnet, FTP, WebView, SNMP, etc.) are “locked out” until they are manually unlocked by the user.
You can also unlock session types on a one-by-one basis. For example, to unlock Telnet sessions only, enter the following command:
-> aaa authentication telnet local
The CLI command used to unlock session types is aaa authentication.
To unlock WebView (HTTP) sessions only, enter the follow- ing command:
-> aaa authentication http local
You cannot specify more than one session type in a single command line. However, you can still unlock multiple session types by using the aaa authentication command in succes- sion. For example:
-> aaa authentication http local -> aaa authentication telnet local -> aaa authentication ftp local
Unlocking All Session Types
To unlock all session types, enter the following command syntax at the CLI prompt:
-> aaa authentication default local
16 Your First Login Session June 2007

All subsequent login sessions—including those through the console port—will require the new password in order to access the switch.
Change the login password for admin user sessions by follow- ing the steps below:
User Accounts. The switch allows a maximum of 50 user accounts in the local user database. For information on creating additional user types and assigning individual passwords, refer to the “Managing Switch User Accounts” chapter of your OmniSwitch 6800/6850/9000 Switch Management Guide.
1 Be sure that you have logged into the switch as user type admin (see “Logging in to the Switch” on page 14).
2 Enter the keyword password and press Enter.
3 Enter your new password at the prompt (refer to the note below).
4 You will be prompted to re-enter the password. Enter the password a second time.
New password settings are automatically saved in real time to the local user database; the user is not required to enter an additional command in order to save the password informa- tion. Also note that new password information is retained following a reboot.
June 2007 Your First Login Session 17

To set the current date for the switch, enter system date, followed by the current date in mm/dd/yyyy. For example:
The switch’s default time zone is UTC (also referred to as Greenwich Mean Time).
-> system date 06/27/2005
If you require a time zone that is specific to your region—or if you need to enable Daylight Savings Time (DST) on the switch—you can configure these settings via the system timezone and system daylight savings time commands. For example, to set the system clock to run on Pacific Standard Time, enter the following command:
This section provides information on configuring optional system parameters, including:
-> system timezone pst
To enable Daylight Savings Time, enter the following command:
-> system daylight savings time enable
Many other time zone variables are supported. For detailed information on configuring a time zone for the switch, refer to your OmniSwitch 6800/6850/9000 Switch Management Guide.
An administrative contact is the person or department in charge of the switch. If a contact is specified, users can easily find the appropriate network administrator if they have ques- tions or comments about the switch.
Set the current time for the switch by entering system time, followed by the current time in hh:mm:ss. For example:
To specify an administrative contact, enter system contact, followed by a text string of up to 254 characters. If you include spaces between words in the text string, be sure to enclose the string in quotes (" ").
-> system time 18:35:00
The switch uses a 24-hour clock; the time value shown in the above example would set the time to 6:35 PM.
For example:
-> system contact "JSmith js@company.com"
18 Your First Login Session June 2007

The system name is a simple, user-defined text description for the switch.
To view your current changes, enter show system at the CLI prompt.
To specify a system name, enter system name, followed by a text description of up to 19 characters.
Once you have configured this basic switch information, save your changes by entering write memory at the CLI command prompt.
When the write memory command is entered, changes are automatically saved to the main configuration file (boot.cfg) and placed in the /flash/working directory. For more informa- tion on the boot.cfg file, refer to page 20.
For example:
-> system name EngSwitch3
It is recommended that you use a physical labeling system for locating and identifying your switch(es). Examples include placing a sticker or placard with a unique identifier (e.g., the switch’s default IP address) on each chassis.
However, if no labeling system has been implemented or if you need to determine a switch’s location from a remote site, entering a system location can be very useful.
This completes the initial configuration process. Your OmniSwitch 6850 Series switch is now ready for additional configuration and network operation. Refer to the following sections for more information on using your switch, as well as additional built-in features.
To specify a system location, enter system location, followed by a text description of up to 254 characters. If you include spaces between words in the text string, be sure to enclose the string in quotes (" ").
For stacked configurations, be sure to refer to the OmniSwitch 6850 Series Hardware Users Guide.
For example:
-> system location "NMS Lab--NE Rack"
June 2007 Your First Login Session 19

Boot and Image Files
The boot.cfg file stores your network configuration parame- ters. When you first boot the switch, no boot.cfg file is present. This file is automatically generated when you first issue a write memory command to save your configuration changes. The file is then automatically placed in the /flash/working directory.
Although the flash memory on OmniSwitch 6850 Series switches can contain many file types (e.g., log and snapshot files), there are four specific file types that provide key switch and network functions. These files include the boot.cfg file, boot.params file, boot.slot.cfg file, and image (.img) files.
The boot.params file provides IP address, gateway, and mask information for the switch. This information is required for Ethernet connections to the switch.
This file also contains default console port parameters (baud rate, etc.) and can be modified via the modify boot parameters CLI command.
Once the configuration parameters stored in the boot.cfg file are considered tested and reliable, the file can be copied to the /flash/certified directory and become part of the “last known good” software for the switch.
In order to be read by the switch, the boot.params file must be placed in the /flash directory. If the file is deleted for any reason, a new boot.params file will be automatically gener- ated on the next system boot. However, all user-configured information, such as IP address, gateway, and mask informa- tion, will be lost. Therefore, it is recommended that you keep a backup copy of this file at all times.
If all copies of this file are deleted and a system boot occurs, your network configuration will be lost. Therefore, it is recom- mended that you keep a backup copy of this file at all times.
20 Files and Directories June 2007

For a complete list of OmniSwitch 6850 Series image files, along with their functions, refer to the following table:
Image files (those files with .img extensions) contain an executable code that provides support for the system, Ethernet ports, and network functions. In other words, they serve as essential drivers for switch and network operations.
K2os.img Contains the OmniSwitch 6850 Series operating system software.
Kbase.img Contains base code for the switch.
Krelease.img Contains release number information for the system software package.
Although these files may be backed up to the root flash direc- tory or any user-defined subdirectory, they must be present in the /flash/working and /flash/certified directories for the switch to operate and pass traffic.
Keni.img Provides support for 10/100/1000 and Gigabit Ethernet.
Kadvrout.img Alcatel-Lucent’s Advanced Routing software package. Optional.
If you delete all copies of an image file, you will be required to contact Alcatel-Lucent Customer Support for replacements. Therefore, it is recommended that you keep backup copies on your computer’s hard drive or a locally-accessible server.
Ksecu.img Provides enhanced security features for the switch, such as Authenticated VLANs (AVLANs).
K2diag.img Provides enhanced hardware diagnostics for the switch.
June 2007 Files and Directories 21

Working Directory Intended for: Files that are being configured and tested. Once these files are considered valid and reliable, they can be copied to the Certified directory. On reload: If the Working and Certified directories are identical, the switch will automatically run from software in this directory. If the two directories are not identical, you can instruct the switch to run from the Working directory by issuing the reload working command.
OmniSwitch 6850 Series switches offer flash memory with 8 MB base ROM space and 64 MB extended ROM. This mem- ory is used to store files, including boot and image files, that are used for switch operations.
The /flash directory contains two subdirectories: /working and /certified. These directories work together to provide the image rollback resiliency feature. Image rollback allows the switch to return to a prior “last known good” version of soft- ware in the event of a system software problem.
Saving changes: You can save config- uration changes to the Working directory via the write memory command.
The /flash/working directory is intended for software that is still being configured for your network. Changes made while configuring your switch are saved to the boot.cfg file in the /flash/working directory.
Once the /flash/working directory’s configuration and image files are road-tested and considered valid and reliable for your network, they can be copied to the /flash/certified directory.
22 Files and Directories June 2007
Working Directory

How can I tell which directory the switch is currently using?
When you first boot the switch, the /flash/working directory is used; this allows you to save your initial configuration changes to the boot.cfg file. However, subsequent boots may result in your switch running from the /flash/certified directory. There- fore, verifying the current running directory is a key step any time you are configuring or monitoring the switch.
Certified Directory Intended for: Reliable, Tested configuration and image files. The switch will roll back to this software in the event of a system software error.
On reload: By default, the switch will use the software in this directory if there are any differences between the Working and Certified directories.
View the switch’s current running directory by entering the show running-directory command. For example:
Saving changes: You cannot save config- uration changes to the Certified directory. To save your changes, be sure that your switch is operating from the Working directory.
Running CMM : PRIMARY, CMM Mode : DUAL CMMs, Current CMM Slot : 1, Running configuration : WORKING, Certify/Restore Status : CERTIFY NEEDED SYNCHRONIZATION STATUS
The software in the /flash/certified directory should be treated as the “gold master” for the switch. When you place configu- ration and image files in this directory, you are “certifying” them as tested and reliable. If the switch is running from the /flash/working directory and experiences a software problem, it will “roll back” to the last known good software in the /flash/certified directory on the next reboot.
In this example, the switch is using the /flash/working direc- tory. For more information on the show running-directory command output, refer to the “CMM Commands” chapter in the OmniSwitch CLI Reference Guide.
June 2007 Files and Directories 23
Certified Directory · -> show running-directory

Can I save changes to the Certified directory?
Working and Certified Are Identical
No. The /flash/certified directory is intended to store only tested, reliable configuration and image files. Configuration changes must be saved to the boot.cfg file in the /flash/working directory. Once those changes have been road- tested, the contents of the /flash/working directory can be copied to the /flash/certified directory via the copy working certified command.
If the software in the /flash/working and /flash/certified directories are completely identical, the switch considers the software in both directories to be equally reliable. In this case, the switch will run from the /flash/working directory.
The switch runs from Working.
boot.cfg K2base.img K2release.img Etc.
boot.cfg K2base.img K2release.img Etc.
What happens when the switch boots?
Working and Certified contents are identical.
During the boot process, the switch compares the contents of the /flash/working and /flash/certified directories. Based on this comparison, the switch determines which directory to use as its running software.
Certified Directory boot.cfg Hbase.img Hrelease.img Etc.
boot.cfg K2base.img K2release.img Etc.
When the switch is running from the /flash/working directory software, configuration changes can be saved via the write memory command.
24 Files and Directories June 2007
Working Directory · Working Directory · Certified Directory

Working and Certified Are Different
My Working and Certified directories are different. Can I force a reboot from the Working directory?
If the software in the /flash/working directory differs even slightly from the software in the /flash/certified directory, the switch will automatically run from the /flash/certified directory.
Yes. If its configuration and image files are known to be reli- able, you can override the default and initiate a reboot from the /flash/working directory. This is done via the reload working command. For more information, refer to your OmniSwitch CLI Reference Guide.


boot.cfg Hbase.img Hrelease.img Etc. Working and Certified contents are different.
The reload working command overrides the default; the switch runs from Working.
revised_boot.cfg K2base.img K2release.img Etc. Working and Certified contents are different.
When the switch runs from the /flash/certified directory, configuration changes cannot be saved via the write memory command.
June 2007 Files and Directories 25

The switch can be configured and monitored using WebView, Alcatel-Lucent’s Web-based device management tool. WebView software is pre-installed in the switch; you are not required to load additional software.
To access WebView and log in to a switch:
1 Open any Alcatel-Lucent-tested Web browser.
The following Web browsers are recommended for use with WebView:
26 Using WebView June 2007

2 Enter the switch’s IP address in the browser’s “Address” text field (“Location:” for Netscape users). The login screen displays.
After you have successfully logged in, the Chassis Manage- ment home page displays.


3 Enter the user name and password at the login prompt.
Remember, if you have already changed the user name and password for your switch, be sure to use the new information. If you have not changed your user name or password, the factory defaults are admin and switch, respectively. Refer to the “Managing Switch User Accounts” chapter of your OmniSwitch 6800/6850/9000 Switch Management Guide for information on modifying the default user name and password.
The Chassis Management home page provides a physical representation of the switch, as well as basic system informa- tion. This is the main launching point for WebView.
June 2007 Using WebView 27

Navigate the application by clicking on the “Configuration Group” buttons in the left-hand toolbar.
Refine your navigation by selecting “Configuration Options” for each group from the items displayed in the grey, horizontal navigation bar.


“Configuration Options” Toolbar.
(In this case, the option “Device” has been selected.)
Main “Configuration Group” Toolbar.
(In this case, the group “Health” has been selected.)
Site Maps. WebView also provides site maps for each configuration group. Site maps allow you to view complete page contents under each feature. By providing quick, easy access to specific pages, site maps can reduce time spent searching through the WebView application. To access site maps, click the “Site Map” link included on each configuration group Home page, (e.g., Health).
28 Using WebView June 2007

Additional Information
General online help is available through the main Help link located in the top WebView banner.
For more information on using WebView, refer to the “Using WebView” chapter in the OmniSwitch 6800/6850/9000 Switch Management Guide.

Detailed, context-based help is provided for each status table and configuration dialog window.

Context-specific Help button.(In this case, for the VLAN Administration table.)
June 2007 Using WebView 29
General Help Link

The WebView login screen does not display. This suggests either a physical or network connection issue. Try the following options:
The login screen displays, but the login fails.
This suggests either a user name and password or Authenti- cated Switch Access error. Try the following options:
-> aaa authentication http local
See page 16 for information on unlocking session types.
30 Using WebView June 2007