EN
Alcatel-Lucent logo
Official user manual

Alcatel-Lucent 6624

114 pages·3.9 MB·Switch·PDF·ENDEFRITNLJA
Alcatel-Lucent 6624
Table of Contents 142 sections Home · Front Matter · Copyright Information · Patents · … ShowHide
Homep.1Front Matterp.2Copyright Informationp.2Patentsp.2Contacting Alcatelp.2Contentsp.3About This Guidep.7Supported Platformsp.7Who Should Read this Manual?p.8When Should I Read this Manual?p.8What is in this Manual?p.8What is Not in this Manual?p.8How is the Information Organized?p.9Documentation Roadmapp.9Related Documentationp.11User Manual CDp.12Technical Supportp.121. OmniSwitch 6600 Seriesp.13Stand-Alone and Stacked Configurationsp.14Stand-Alonep.14Stacked Configurationsp.14Availability Featuresp.15Smart Continuous Switchingp.15Software Rollbackp.16Hot Swappingp.16Hardware Monitoringp.16Port and Fabric Capacitiesp.17Application Examplesp.18Single Office Building with 1000 Usersp.18Medium Campus with 1500 Usersp.192. OmniSwitch 6600 Series Chassis and Hardware Componentsp.21OmniSwitch 6624p.23OmniSwitch 6600-U24p.25OmniSwitch 6648p.29Status LEDsp.31Rear Panelp.32Mounting the Switchp.33Airflow Considerationsp.33Installation Optionsp.34Installing the Switch on a Tabletop or Benchp.34Rack-Mounting the Switchp.34Rack Mounting Stacked Configurationsp.36Power Cordsp.37Grounding the Chassisp.37Back Up Power Supplyp.38Power Supply Redundancyp.38Redundant AC Circuit Recommendationp.39Installing a Back Up Power Supplyp.40Removing a Back Up Power Supplyp.42Blank Cover Panel Requirementp.43Viewing Primary and Back Up Power Supply Statusp.43Viewing Power Supply Status for Stacked Configurationsp.44A Slot Number is Specifiedp.44No Slot Number is Specifiedp.44Gigabit Ethernet Uplink Modulesp.45OS6600-GNI-U2p.45OS6600-GNI-C2p.47Stacking Modulep.48Installing Uplink and Stacking Modulesp.49Removing Uplink and Stacking Modulesp.51Blank Cover Panel Requirementp.52Mini Gigabit Interface Converters (MiniGBICs)p.53MiniGBIC Specificationsp.54Installing MiniGBICsp.55Removing MiniGBICsp.56100 Mbps SFPs (OS6600-U24)p.57100 Mbps SFP Specificationsp.58Installing SFPs (OS6600-U24)p.60Removing SFPs (OS6600-U24)p.61Temperature Managementp.62Viewing Chassis Temperature Statusp.62Viewing Temperature Status for Stacked Configurationsp.63A Slot Number is Specifiedp.63No Slot Number is Specifiedp.63Temperature Errorsp.64Warning Thresholdp.64Danger Thresholdp.64Viewing Fan Statusp.65Viewing Fan Status for Stacked Configurationsp.65A Slot Number is Specifiedp.65No Slot Number is Specifiedp.66Chassis Airflowp.67Blank Cover Panelsp.68Pinoutsp.69Console Portp.71Serial Connection to the Console Portp.71Viewing Basic Chassis Informationp.73Managing MAC Addresses on the Switchp.79MAC Range Guidelinesp.79OmniSwitch 6600 Series MAC Range Specificationsp.79Base Chassis MAC Address as Unique Identifierp.80Determining Current MAC Address Allocation on the Switchp.80Base Chassis MAC Address in Stacked Configurationsp.803. Managing OmniSwitch 6600 Series Stacksp.81In This Chapterp.81Specifications and Default Valuesp.82Stack Overviewp.83Stacking Resiliency and Redundancyp.84Slot Numbers within a Stackp.84CMM Roles in a Stackp.85CMM Role Redundancyp.85CLI Commands Supported on Both the Primary and Secondary Role Switchesp.86Setting Up a Stacked Configurationp.88Assigning Slot Numbersp.88Slot Numbering Examplep.90Connecting Cables to Stacking Portsp.91Redundant Stack Connectionp.93Booting the Stackp.94Verifying Slot Number Assignmentsp.94Verifying Primary and Secondary Status for the Stackp.94Managing Switches in a Stackp.96Reloading a Switch with a Primary or Secondary CMM Rolep.96Synchronizing Switches in a Stackp.97Restoring Switch Redundancyp.97Changing the Secondary CMM Role to Primaryp.98Module Behavior During Takeoverp.98Resetting All Switches in a Stackp.99Monitoring Stacksp.100Monitoring Stack Topologyp.100A. Regulatory Compliance and Safety Informationp.103Declaration of Conformity: CE Markp.103Standards Compliancep.104FCC Class A, Part 15p.105Canada Class A Statementp.105JATEp.105CISPR22 Class A warningp.105VCCIp.106Class A Warning for Taiwan and Other Chinese Marketsp.106Translated Safety Warningsp.107Chassis Lifting Warningp.107Blank Panels Warningp.107Electrical Storm Warningp.107Installation Warningp.108Invisible Laser Radiation Warningp.108Lithium Battery Warningp.109Operating Voltage Warningp.109Power Disconnection Warningp.110Proper Earthing Requirement Warningp.110Read Important Safety Information Warningp.111Restricted Access Location Warningp.111Wrist Strap Warningp.112Indexp.113
Page 1 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6624/6648
Page 1 · click to enlarge
Page 1

Part No. 060181-10, Rev. C April 2004

OmniSwitch 6624/6648

Hardware Users Guide

Page 2 of the Alcatel-Lucent 6624 user manual — Front Matter
Page 2 · click to enlarge
Page 2

This user guide documents OmniSwitch 6600 Series hardware, including

chassis and associated components. The specifications described in this guide are subject to change without notice.

Copyright © 2004 by Alcatel Internetworking, Inc. All rights reserved. This document may not be repro- duced in whole or in part without the express written permission of Alcatel Internetworking, Inc.

Alcatel® and the Alcatel logo are registered trademarks of Alcatel. Xylan®, OmniSwitch®, OmniStack®, and Alcatel OmniVista® are registered trademarks of Alcatel Internetworking, Inc.

OmniAccess™, Omni Switch/Router™, PolicyView™, RouterView™, SwitchManager™, VoiceView™, WebView™, X-Cell™, X-Vision™, and the Xylan logo are trademarks of Alcatel Internetworking, Inc.

This OmniSwitch product contains components which may be covered by one or more of the following U.S. Patents:

  • U.S. Patent No. 6,339,830
  • U.S. Patent No. 6,070,243
  • U.S. Patent No. 6,061,368
  • U.S. Patent No. 5,394,402
  • U.S. Patent No. 6,047,024
  • U.S. Patent No. 6,314,106
  • U.S. Patent No. 6,542,507

26801 West Agoura Road Calabasas, CA 91301 (818) 880-3500 FAX (818) 880-3505

info@ind.alcatel.com

US Customer Support—(800) 995-2696 International Customer Support—(818) 878-4507

Internet—http://eservice.ind.alcatel.com

ii OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 3 of the Alcatel-Lucent 6624 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Homep.1Front Matterp.2Copyright Informationp.2Patentsp.2Contacting Alcatelp.2Contentsp.3About This Guidep.7Supported Platformsp.7Who Should Read this Manual?p.8When Should I Read this Manual?p.8What is in this Manual?p.8What is Not in this Manual?p.8How is the Information Organized?p.9Documentation Roadmapp.9Related Documentationp.11User Manual CDp.12Technical Supportp.121. OmniSwitch 6600 Seriesp.13Stand-Alone and Stacked Configurationsp.14Stand-Alonep.14Stacked Configurationsp.14Availability Featuresp.15Smart Continuous Switchingp.15Software Rollbackp.16Hot Swappingp.16Hardware Monitoringp.16Port and Fabric Capacitiesp.17Application Examplesp.18Single Office Building with 1000 Usersp.18Medium Campus with 1500 Usersp.192. OmniSwitch 6600 Series Chassis and Hardware Componentsp.21OmniSwitch 6624p.23OmniSwitch 6600-U24p.25OmniSwitch 6648p.29Status LEDsp.31Rear Panelp.32Mounting the Switchp.33Airflow Considerationsp.33Installation Optionsp.34Installing the Switch on a Tabletop or Benchp.34Rack-Mounting the Switchp.34Rack Mounting Stacked Configurationsp.36Power Cordsp.37Grounding the Chassisp.37Back Up Power Supplyp.38Power Supply Redundancyp.38Redundant AC Circuit Recommendationp.39Installing a Back Up Power Supplyp.40Removing a Back Up Power Supplyp.42Blank Cover Panel Requirementp.43Viewing Primary and Back Up Power Supply Statusp.43Viewing Power Supply Status for Stacked Configurationsp.44A Slot Number is Specifiedp.44No Slot Number is Specifiedp.44Gigabit Ethernet Uplink Modulesp.45OS6600-GNI-U2p.45OS6600-GNI-C2p.47Stacking Modulep.48Installing Uplink and Stacking Modulesp.49Removing Uplink and Stacking Modulesp.51Blank Cover Panel Requirementp.52Mini Gigabit Interface Converters (MiniGBICs)p.53MiniGBIC Specificationsp.54Installing MiniGBICsp.55Removing MiniGBICsp.56100 Mbps SFPs (OS6600-U24)p.57100 Mbps SFP Specificationsp.58Installing SFPs (OS6600-U24)p.60Removing SFPs (OS6600-U24)p.61Temperature Managementp.62Viewing Chassis Temperature Statusp.62Viewing Temperature Status for Stacked Configurationsp.63A Slot Number is Specifiedp.63No Slot Number is Specifiedp.63Temperature Errorsp.64Warning Thresholdp.64Danger Thresholdp.64Viewing Fan Statusp.65Viewing Fan Status for Stacked Configurationsp.65A Slot Number is Specifiedp.65No Slot Number is Specifiedp.66Chassis Airflowp.67Blank Cover Panelsp.68Pinoutsp.69Console Portp.71Serial Connection to the Console Portp.71Viewing Basic Chassis Informationp.73Managing MAC Addresses on the Switchp.79MAC Range Guidelinesp.79OmniSwitch 6600 Series MAC Range Specificationsp.79Base Chassis MAC Address as Unique Identifierp.80Determining Current MAC Address Allocation on the Switchp.80Base Chassis MAC Address in Stacked Configurationsp.803. Managing OmniSwitch 6600 Series Stacksp.81In This Chapterp.81Specifications and Default Valuesp.82Stack Overviewp.83Stacking Resiliency and Redundancyp.84Slot Numbers within a Stackp.84CMM Roles in a Stackp.85CMM Role Redundancyp.85CLI Commands Supported on Both the Primary and Secondary Role Switchesp.86Setting Up a Stacked Configurationp.88Assigning Slot Numbersp.88Slot Numbering Examplep.90Connecting Cables to Stacking Portsp.91Redundant Stack Connectionp.93Booting the Stackp.94Verifying Slot Number Assignmentsp.94Verifying Primary and Secondary Status for the Stackp.94Managing Switches in a Stackp.96Reloading a Switch with a Primary or Secondary CMM Rolep.96Synchronizing Switches in a Stackp.97Restoring Switch Redundancyp.97Changing the Secondary CMM Role to Primaryp.98Module Behavior During Takeoverp.98Resetting All Switches in a Stackp.99Monitoring Stacksp.100Monitoring Stack Topologyp.100A. Regulatory Compliance and Safety Informationp.103Declaration of Conformity: CE Markp.103Standards Compliancep.104FCC Class A, Part 15p.105Canada Class A Statementp.105JATEp.105CISPR22 Class A warningp.105VCCIp.106Class A Warning for Taiwan and Other Chinese Marketsp.106Translated Safety Warningsp.107Chassis Lifting Warningp.107Blank Panels Warningp.107Electrical Storm Warningp.107Installation Warningp.108Invisible Laser Radiation Warningp.108Lithium Battery Warningp.109Operating Voltage Warningp.109Power Disconnection Warningp.110Proper Earthing Requirement Warningp.110Read Important Safety Information Warningp.111Restricted Access Location Warningp.111Wrist Strap Warningp.112Indexp.113
Page 7 of the Alcatel-Lucent 6624 user manual — Unsupported Platforms
Page 7 · click to enlarge
Page 7

About This Guide

This OmniSwitch 6660 Series Hardware Users Guide describes your switch hardware components and basic switch hardware procedures.

Supported Platforms

This information in this guide applies to the following products:

  • OmniSwitch 6624
  • OmniSwitch 6600-U24
  • OmniSwitch 6648

OmniSwitch 6600 series switches are next generation enterprise edge/workgroup switches. The OmniSwitch 6624 offers 24 copper 10/100 ports, the 6648 offers 48 copper 10/100 ports, and the 6600- U24 offers 24 fiber 100 ports.

In addition, OmniSwitch 6624/6600-U24/6648 switches have one expansion port that can be used for a Gigabit Ethernet uplink module and another expansion port that can be used for a Gigabit Ethernet uplink or a stacking module. The stacking ports on all OmniSwitch 6600 series switches allow two to eight OmniSwitch 6600 series switches to be configured as one virtual chassis known as a stack.

Unsupported Platforms

The information in this guide does not apply to the following products:

  • OmniSwitch (original version with no numeric model name)
  • OmniSwitch 7700
  • OmniSwitch 7800
  • OmniSwitch 8800
  • Omni Switch/Router
  • OmniStack
  • OmniAccess

OmniSwitch 6600 Series Hardware Users Guide April 2004 page vii

Page 8 of the Alcatel-Lucent 6624 user manual — What is Not in this Manual?
Page 8 · click to enlarge
Page 8

Who Should Read this Manual? About This Guide

Who Should Read this Manual?

The audience for this users guide is network administrators and IT support personnel who need to config- ure, maintain, and monitor switches and routers in a live network. However, anyone wishing to gain knowledge on the OmniSwitch 6600 series hardware will benefit from the material in this guide.

When Should I Read this Manual?

Read this guide as soon as you are ready to familiarize yourself with your switch hardware components. You should have already stepped through the first login procedures and read the brief hardware overviews in the OmniSwitch 6600 series Getting Started Guide.

You should already be familiar with the very basics of the switch hardware, such as module LEDs and module installation procedures. This manual will help you understand your switch hardware components (chassis, cooling fans, power supplies, Gigabit uplink modules, stacking modules, backup power supplies) in greater depth.

What is in this Manual?

This users guide includes the following hardware-related information:

  • Descriptions of stand-alone and stacked configurations.
  • Descriptions of “Availability” features.
  • Descriptions of chassis types (OS6624, OS6600-U24, and OS6648).
  • Instructions for mounting chassis.
  • Descriptions of hardware components (status LEDs, Gigabit uplink modules, stacking modules, backup power supplies, MiniGBICs)
  • Managing stand-alone chassis.
  • Setting up stacks.
  • Managing stacks.
  • Hardware-related Command Line Interface (CLI) commands

What is Not in this Manual?

The descriptive and procedural information in this manual focuses on switch hardware. It includes infor- mation on some CLI commands that pertain directly to hardware configuration, but it is not intended as a software users guide. There are several OmniSwitch 6600 series users guides that focus on switch soft- ware configuration. Consult those guides for detailed information and examples for configuring your switch software to operate in a live network environment. See “Documentation Roadmap” on page ix and “Related Documentation” on page xi for further information on software configuration guides available for your switch.

page viii OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 9 of the Alcatel-Lucent 6624 user manual — Stage 2: Gaining Familiarity with Basic Switch Functions
Page 9 · click to enlarge
Page 9

About This Guide How is the Information Organized?

How is the Information Organized?

This users guide provides an overview of OmniSwitch 6600 series switches in the first chapter, an over- view and procedures for setting up and managing OmniSwitch 6600 series switches in the second chapter, and an overview and procedures for setting up and managing stacks in the third chapter.

Documentation Roadmap

The OmniSwitch user documentation suite was designed to supply you with information at several critical junctures of the configuration process.The following section outlines a roadmap of the manuals that will help you at each stage of the configuration process. Under each stage, we point you to the manual or manuals that will be most helpful to you.

Stage 1: Using the Switch for the First Time

Pertinent DocumentationOmniSwitch 6600 Series Getting Started Guide

A hard-copy OmniSwitch 6600 Series Getting Started Guide is included with your switch; this guide provides all the information you need to get your switch up and running the first time. This guide provides information on unpacking the switch, rack mounting the switch, installing uplink and stacking modules, unlocking access control, setting the switch’s IP address, setting up a password, and setting up stacks. It also includes succinct overview information on fundamental aspects of the switch, such as hardware LEDs, the software directory structure, stacking, CLI conventions, and web-based management.

At this time you should also familiarize yourself with the Release Notes that accompanied your switch. This document includes important information on feature limitations that are not included in other user guides.

Stage 2: Gaining Familiarity with Basic Switch Functions

Pertinent DocumentationOmniSwitch 6600 Series Hardware Users Guide

OmniSwitch 6624/6648 Switch Management Guide

Once you have your switch up and running, you will want to begin investigating basic aspects of its hard ware and software. Information about switch hardware is provided in the OmniSwitch 6600 Series Hard- ware Users Guide. This guide provide specifications, illustrations, and descriptions of all hardware components–chassis, power supplies, uplink and stacking modules, and cooling fans. It also includes steps for common procedures, such as removing and installing switch modules.

The OmniSwitch 6624/6648 Switch Management Guide is the primary user guide for the basic software features on a single switch. This guide contains information on the switch directory structure, basic file and directory utilities, switch access security, SNMP, and web-based management. It is recommended that you read this guide before connecting your switch to the network.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page ix

Release Notes

Page 10 of the Alcatel-Lucent 6624 user manual — Anytime
Page 10 · click to enlarge
Page 10

Documentation Roadmap About This Guide

Stage 3: Integrating the Switch Into a Network

Pertinent DocumentationOmniSwitch 6624/6648 Network Configuration Guide

OmniSwitch 6624/6648 Advanced Routing Configuration Guide

When you are ready to connect your switch to the network, you will need to learn how the OmniSwitch implements fundamental software features, such as 802.1Q, VLANs, and Spanning Tree. The OmniSwitch 6624/6648 Network Configuration Guide contains overview information, procedures and examples on how standard networking technologies are configured in the OmniSwitch 6600 series.

The OmniSwitch 6624/6648 Advanced Routing Configuration Guide includes configuration information for networks using Open Shortest Path First (OSPF).

Anytime

The OmniSwitch CLI Reference Guide contains comprehensive information on all CLI commands supported by the switch. This guide includes syntax, default, usage, example, related CLI command, and CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can be consulted anytime during the configuration process to find detailed and specific information on each CLI command.

page x OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 11 of the Alcatel-Lucent 6624 user manual — Related Documentation
Page 11 · click to enlarge
Page 11

About This Guide Related Documentation

Related Documentation

The following are the titles and descriptions of all the OmniSwitch 6600 series user manuals:

  • OmniSwitch 6600 Series Getting Started Guide

Describes the hardware and software procedures for getting an OmniSwitch 6600 series switch up and running. Also provides information on fundamental aspects of OmniSwitch software and stacking architecture.

  • OmniSwitch 6600 Series Hardware Users Guide

Complete technical specifications and procedures for all OmniSwitch 6600 series chassis, power supplies, fans, and uplink and stacking modules.

  • OmniSwitch CLI Reference Guide

Complete reference to all CLI commands supported on the OmniSwitch 6624, 6600-U24, 6648, 7700, 7800, and 8800. Includes syntax definitions, default values, examples, usage guidelines and CLI-to- MIB variable mappings.

  • OmniSwitch 6624/6648 Switch Management Guide

Includes procedures for readying an individual switch for integration into a network. Topics include the software directory architecture, image rollback protections, authenticated switch access, managing switch files, system configuration, using SNMP, and using web management software (WebView).

  • OmniSwitch 6624/6648 Network Configuration Guide

Includes network configuration procedures and descriptive information on all the major software features and protocols included in the base software package. Chapters cover Layer 2 information (Ethernet and VLAN configuration), Layer 3 information, security options (authenticated VLANs), Quality of Service (QoS), and link aggregation.

  • OmniSwitch 6624/6648 Advanced Routing Configuration Guide

Includes network configuration procedures and descriptive information on all the software features and protocols included in the advanced routing software package. Chapters cover the Open Shortest Path First (OSPF) Protocol.

  • Technical Tips, Field Notices

Includes information published by Alcatel’s Customer Support group.

  • Release Notes

Includes critical Open Problem Reports, feature exceptions, and other important information on the features supported in the current release and any limitations to their support.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page xi

Page 12 of the Alcatel-Lucent 6624 user manual — Technical Support
Page 12 · click to enlarge
Page 12

User Manual CD About This Guide

User Manual CD

All user guides for the OmniSwitch 6600 series are included on the User Manual CD that accompanied your switch. This CD also includes user guides for other Alcatel data enterprise products. In addition, it contains a stand-alone version of the on-line help system that is embedded in the OmniVista network management application.

Besides the OmniVista documentation, all documentation on the User Manual CD is in PDF format and requires the Adobe Acrobat Reader program for viewing. Acrobat Reader freeware is available at www.adobe.com

To verify that you are using Acrobat Reader with the global search option, look for the following button in the toolbar:

Technical Support

An Alcatel service agreement brings your company the assurance of 7x24 no-excuses technical support. You’ll also receive regular software updates to maintain and maximize your Alcatel product’s features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel’s Service and Support web page, you’ll be able to view and update any case (open or closed) that you have reported to Alcatel’s technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more infor- mation on Alcatel’s Service Programs, see our web page at www.ind.alcatel.com call us at 1-800-995- 2696, or email us at support@ind.alcatel.com.

page xii OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 13 of the Alcatel-Lucent 6624 user manual — CONSOLE
Page 13 · click to enlarge
Page 13

1 OmniSwitch 6600 Series

The OmniSwitch 6600 series switches consist of the OmniSwitch 6624 (OS6624), OmniSwitch 6600-U24 (OS6600-U24), and the OmniSwitch 6648 (OS6648). The OmniSwitch 6600 series switches are next generation enterprise edge/workgroup switches. These switches are based on the same software architec- ture as OmniSwitch 7000 and 8000 series switches (i.e., OS7700, OS7800, and OS8800) and are designed to meet the most stringent network requirements for mission-critical networks.

OmniSwitch 6600 series switches are optimized for voice and data integration and provide non-blocking multi-Gigabit Ethernet capacity. Additional features include Carrier-class intelligence, best of breed QoS, Carrier-class resiliency, network management, and advanced policy-based VLANs and security. OmniSwitch 6600 series switches also support wirespeed Layer 2 and Layer 3 switching, industry-based standards, and a full array of reliability, redundancy and resiliency capabilities.

EXPANSION/STACKING EXPANSION 25 26 2 7 2 8

LINK/ACT LINK/ACT LINK/ACT LINK/ACT

Alcatel-Lucent 6624 — EXPANSION/STACKING EXPANSION 25 26 2 7 2 8 diagram (page 13)
Fig. 1
Alcatel-Lucent 6624 — EXPANSION/STACKING EXPANSION 25 26 2 7 2 8 diagram (page 13)
Fig. 2
Alcatel-Lucent 6624 — EXPANSION/STACKING EXPANSION 25 26 2 7 2 8 diagram (page 13)
Fig. 3

3 5 7 9 11 13 15 17 19 21 23 1

2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23

Alcatel-Lucent 6624 — EXPANSION/STACKING EXPANSION 25 26 2 7 2 8 diagram (page 13)
Fig. 4
Alcatel-Lucent 6624 — EXPANSION/STACKING EXPANSION 25 26 2 7 2 8 diagram (page 13)
Fig. 5

EXPANSION/STACKING

Alcatel-Lucent 6624 — EXPANSION/STACKING diagram (page 13)
Fig. 6
Alcatel-Lucent 6624 — EXPANSION/STACKING diagram (page 13)
Fig. 7

2 7 2 8

CONSOLE

PS2 PRI SEC TEMP FAN

SEL

LINK/ACT LINK/ACT

PS1

Alcatel-Lucent 6624 — CONSOLE diagram (page 13)
Fig. 8

OK1

OK2

Alcatel-Lucent 6624 — OK1 diagram (page 13)
Fig. 9
Alcatel-Lucent 6624 — OK1 diagram (page 13)
Fig. 10

12 14 16 18 20

Alcatel-Lucent 6624 — OK1 diagram (page 13)
Fig. 11
Alcatel-Lucent 6624 — OK1 diagram (page 13)
Fig. 12

CONSOLE

EXPANSION/STACKING

5 1 5 2

PS1

PRI

TEMP

OK1

OK2

PS2

SEC

FAN

Alcatel-Lucent 6624 — PS1 diagram (page 13)
Fig. 13

30 32 34 36

12 14 16 18 20

CONSOLE

PRI

TEMP

SEL

OK1

PS1

PS2

SEC

FAN

OK2

OmniSwitch 6624/6648 Hardware Users Guide April 2004 page 1-1

Show 6 more labels / short text on this page
OmniSwitch 6600-U24 · OmniSwitch 6624 · TM OmniSwitch 6600-U24 · OmniSwitch 6648 · TM OmniSwitch 6624 · TM OmniSwitch 6624
Page 14 of the Alcatel-Lucent 6624 user manual — Stacked Configurations
Page 14 · click to enlarge
Page 14

Stand-Alone and Stacked Configurations OmniSwitch 6600 Series

Stand-Alone and Stacked Configurations

Stand-Alone

A stand-alone OmniSwitch 6600 series switch is ideal for small and medium-sized network edge applica- tions, offering 24 or 48 10/100 ports, respectively. These switches provide support for enterprise-based devices, such as computer workstations or IP telephones.

A single OmniSwitch 6600 series switch also supports two Gigabit Ethernet uplinks for high-bandwidth connections to a backbone or server.

Stacked Configurations

In addition to working as individual, stand-alone switches, OmniSwitch 6600 series switches can also be linked together to form a single, high-density virtual chassis known as a stack.

Stacking switches provides scalability by allowing users to quickly and easily expand 10/100 port density. Twenty-four 10/100 ports are added for each OS6624 brought into the stack; twenty-four 100 ports are added for each OS6600-U24 brought into the stack; forty-eight 10/100 ports are added for each OS6648.

Up to eight switches can be stacked. OmniSwitch 6600 series switches can be mixed and matched in any combination within the stack. This provides a virtual chassis with a 10/100 or 100 capacity of up to 384 ports.

As with the stand-alone configuration, a stacked virtual chassis configuration provides Gigabit Ethernet uplinks to a backbone or server.

Note on Terminology. In the user manuals provided with your switch, the terms switch, slot and NI (Network Interface) refer to individual OmniSwitch 6600 series units in standalone mode or within a stacked configuration. The term CMM (Chassis Management Module) refers to stacked OmniSwitch 6600 series units operating in primary or secondary CMM roles. (An OmniSwitch 6600 series switch operating in an idle CMM role would normally be referred to as a switch, slot, or, NI.)

page 1-2 OmniSwitch 6624/6648 Hardware Users Guide April 2004

Page 15 of the Alcatel-Lucent 6624 user manual — Smart Continuous Switching
Page 15 · click to enlarge
Page 15

OmniSwitch 6600 Series Availability Features

Availability Features

The switch provides a broad variety of Availability features. Availability features are hardware- and software-based safeguards that help prevent the loss of data flow in the unlikely event of a subsystem fail- ure. In addition, some Availability features allow you to maintain or replace hardware components with- out powering off your switch or interrupting switch operations. Combined, these features provide added resiliency and help ensure that your switch is consistently available for your day-to-day network opera- tions.

Hardware-related Availability features include:

  • Smart Continuous Switching
  • Software Rollback
  • Hot Swapping
  • Hardware Monitoring

Smart Continuous Switching

In stacked configurations, one OmniSwitch 6600 series switch is designated as the primary “management module” for the stack. Because the stack can be thought of as a virtual chassis, the role of this primary management switch is to monitor and manage the functions of the stack.

Similar to chassis-based switches such as the OmniSwitch 7700 and Omniswitch 7800, the stack also allows users to assign an additional switch as a secondary management module. As with the OS7700 and OS7800, the stack’s secondary switch immediately takes over management functions in the event of a primary switch failure.

All other switches in the stack are considered idle, and act very much like Ethernet Network Interface (ENI) modules in OS7700 and OS7800 switches, in that they provide Ethernet ports for 10/100 traffic.

The stack provides support for all idle switches during primary-to-secondary failover. In other words, if the stack’s primary switch fails or goes offline for any reason, all idle switches will continue data trans- mission during the secondary switch’s takeover process. This Availability feature is referred to as Smart Continuous Switching.

Incoming Layer 2 packets will continue to be sent to the appropriate egress port during failover. Spanning Tree will continue handling BPDUs received on the switch ports, as well as port link up and down states. The Spanning Tree topology will not be disrupted.

For more information on primary, secondary, and idle switches, as well as the failover process, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6624/6648 Hardware Users Guide April 2004 page 1-3

Page 16 of the Alcatel-Lucent 6624 user manual — LEDs
Page 16 · click to enlarge
Page 16

Availability Features OmniSwitch 6600 Series

Software Rollback

Software rollback (also referred to as image rollback) essentially allows the OmniSwitch 6600 series switches (in both standalone and stacked configurations) to return to a prior “last known good” version of software in the event of a system software problem. The switch controls software rollback through its resilient directory structure design (i.e., /flash/working and /flash/certified).

For detailed information on the software rollback feature, as well as the switch’s /flash/working and /flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6600 Series Switch Management Guide.

Hot Swapping

Hot swapping refers to the action of adding, removing, or replacing back up power supplies, as well as uplink modules and MiniGBICs, without powering off your switch and disrupting other components in the switch or stack. This feature greatly facilitates hardware upgrades and maintenance and also allows you to easily replace components in the unlikely event of hardware failure. The following hardware components can be hot swapped:

  • OS66BPS-100A Back Up Power Supply
  • OS6600-GNI-C2 Gigabit Ethernet Uplink Submodule
  • OS6600-GNI-U2 Gigabit Ethernet Uplink Submodule
  • MiniGBICs installed in the OS6600-GNI-U 2 Gigabit Ethernet Uplink Submodule; MiniGBICs include:

For instructions on hot swapping back up power supplies, uplink modules, and MiniGBICs, refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components.”

Hardware Monitoring

Automatic Monitoring

Automatic monitoring refers to the switch’s built-in sensors that automatically monitor operations. If an error is detected (e.g., over-threshold temperature), the switch immediately sends a trap to the user. The trap is displayed on the console in the form of a text error message. (In the case of an over-threshold temperature condition, the chassis displays an amber TEMP LED in addition to sending a trap.)

LEDs

LEDs, which provide visual status information, are provided on the chassis front panel. LEDs are used to indicate conditions such as hardware and software status, temperature errors, link integrity, data flow, etc. For detailed LED descriptions, refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components.”

page 1-4 OmniSwitch 6624/6648 Hardware Users Guide April 2004

- MiniGBIC-SX · - MiniGBIC-LX · - MiniGBIC-LH-70

Page 17 of the Alcatel-Lucent 6624 user manual — OS6648 Throughput
Page 17 · click to enlarge
Page 17

OmniSwitch 6600 Series Port and Fabric Capacities

User-Driven Monitoring

User-driven hardware monitoring refers to CLI commands that are entered by the user in order to access the current status of hardware components. The user enters “show” commands that output information to the console. Monitoring information for chassis components such as the optional back up power supply, chassis temperature sensor, and chassis fans is provided in Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components.” Show commands for all features are described in detail in the OmniSwitch CLI Reference Guide.

Port and Fabric Capacities

OmniSwitch 6600 series switches offer 24 10/100 Ethernet ports, 24 100 Ethernet ports, or 48 10/100 Ethernet ports. The switches also offer expansion gigabit uplink and stacking ports. Refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components” for expansion port details.

OmniSwitch 6600 Series Fabric Capacities

OS6624/OS6600-U24 Up to 7.0 Gbps at full duplex; 14.0 Gbps aggregate

OS6648 Up to 10.0 Gbps at full duplex; 20.0 Gbps aggregate

OS6624/6600-U24 Throughput

10/100Mbps Copper Ethernet ports (OS6624 only)

Approximately 3.57 Mpps

100Mbps Fiber Ethernet ports (OS6600-U24 only)

Approximately 3.57 Mpps

Gigabit Ethernet uplink ports Approximately 5.95 Mpps (stand-alone switches with four Gigabit Ethernet uplink modules installed)

Total throughput Approximately 9.52 Mpps

OS6648 Throughput

10/100Mbps Ethernet ports Approximately 7.14 Mpps

Gigabit Ethernet uplink ports Approximately 5.95 Mpps (stand-alone switches with four Gigabit Ethernet uplink modules installed)

Total throughput Approximately 13.09 Mpps

For detailed information on OmniSwitch 6600 series features, functions, and technical specifications, refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components” and Chapter 3, “Managing OmniSwitch 6600 Series Stacks.” For additional general information, including application examples, refer to the sections below.

OmniSwitch 6624/6648 Hardware Users Guide April 2004 page 1-5

Page 18 of the Alcatel-Lucent 6624 user manual — Single Office Building with 1000 Users
Page 18 · click to enlarge
Page 18

Application Examples OmniSwitch 6600 Series

Application Examples

The following application examples show two of the many ways OmniSwitch 6600 series switches can be used in an enterprise network setting.

Single Office Building with 1000 Users

The following diagram shows converged voice and data applications, with 1000 users, in a single building enterprise environment. Edge devices consist of a mixture of PCs and IP telephones. In this example, a single OmniPCX 4400 in the core supports IP voice initiations and terminations. An OmniSwitch 7800 switch provides a port density of 1000 10/100 ports. The stackable OmniSwitch 6600 series configura- tions provide redundant and dual connectivity from the edge to the redundant backbone/core, in which the OmniSwitch 7800 core switches are used.

IP Phones IP Phones

OmniSwitch 7800 Gigabit Gigabit

OmniSwitch 7800 OmniSwitch 7800

Server Farm Server OmniPCX

page 1-6 OmniSwitch 6624/6648 Hardware Users Guide April 2004

Show 9 more labels / short text on this page
IP Phones · Edge · Gigabit · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · Gigabit · Backbone Data Center · Gigabit
Page 19 of the Alcatel-Lucent 6624 user manual — Medium Campus with 1500 Users
Page 19 · click to enlarge
Page 19

OmniSwitch 6600 Series Application Examples

Medium Campus with 1500 Users

This example illustrates converged voice and data applications with 1500 users spread across two build- ings in an enterprise campus. Edge devices consist of a mixture of PCs and IP telephones. And, like the previous example, a single OmniPCX 4400 in the core supports IP voice initiations and terminations.

In building number one, an OmniSwitch 7800 switch provides a port density of 1000 10/100 ports, and the stackable OmniSwitch 6600 series configurations provide redundant and dual connectivity from the edge to the redundant backbone/core. In building number two, the stackable OmniSwitch 6600 series configura- tions provide 500 ports for connectivity from the edge to the backbone/core.

10/100

OmniSwitch 7800 OmniSwitch 7800

Building Number One Building Number Two

OmniSwitch 6624/6648 Hardware Users Guide April 2004 page 1-7

Show 23 more labels / short text on this page
IP Phones · 10/100 10/100 10/100 · OmniSwitch 7800 · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · IP Phones · IP Phones · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · Edge · Edge · Gigabit · Gigabit · OmniSwitch 7800 · Server Farm · OmniPCX · Server Farm · Gigabit · Backbone Data Center · Backbone Data Center
Page 20 of the Alcatel-Lucent 6624 user manual — Medium Campus with 1500 Users
Page 20 · click to enlarge
Page 20

Application Examples OmniSwitch 6600 Series

page 1-8 OmniSwitch 6624/6648 Hardware Users Guide April 2004

Page 21 of the Alcatel-Lucent 6624 user manual — 2 OmniSwitch 6600 Series Chassis and Hardware
Page 21 · click to enlarge
Page 21

2 OmniSwitch 6600 Series Chassis and Hardware

Components

OmniSwitch 6600 series switches are available in five stackable chassis configurations—the 24-port OmniSwitch 6624 (OS6624) and the OmniSwitch 6600-U24 (OS6600-U24) and the 48-port OmniSwitch 6648 (OS6648). This chapter includes detailed information on each of these chassis types. Topics include:

  • OmniSwitch 6600 series chassis descriptions
  • Technical specifications
  • Switch mounting
  • Back up power supply
  • Gigabit Ethernet uplink and stacking modules
  • MiniGBICs
  • 100 Mbps SFPs
  • Temperature management
  • Pinouts and console port specifications
  • Monitoring switch status
  • Base chassis MAC address
Page 22 of the Alcatel-Lucent 6624 user manual — 2. OmniSwitch 6600 Series Chassis and Hardware Components
Page 22 · click to enlarge
Page 22

OmniSwitch 6600 Series Chassis and Hardware Components

Alcatel-Lucent 6624 — 2. OmniSwitch 6600 Series Chassis and Hardware Components diagram (page 22)
Fig. 14 · 2. OmniSwitch 6600 Series Chassis and Hardware Compo…

3 5 7 9 11 13 15 17 19 21 23 1

2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23

Page 23 of the Alcatel-Lucent 6624 user manual — CONSOLE
Page 23 · click to enlarge
Page 23

OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6624

OmniSwitch 6624

The OS6624 is a stackable edge/workgroup switch offering 24 10/100 Ethernet ports. The OS6624 can also be equipped with up to four Gigabit Ethernet ports for connections to a high speed backbone or server.

The front panel of the OS6624 chassis contains the following major components:

  • Console (DB-9) port
  • Stack indicator LED
  • 24 10/100 Ethernet ports
  • One slot for OS6600-GNI-U2 (fiber) or OS6600-GNI-C2 (copper) Gigabit Ethernet uplink module
  • One slot for Gigabit Ethernet uplink module as described above or stacking module

Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-11. For information on the chassis rear panel, refer to page 2-12.

Gigabit Ethernet Uplink Module Slot The OS6624 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:

Console Port The OS6624 front panel provides one RS232 port for console connections. Serial console connections are used by network administrators for switch management. This female DB-9 con- nector provides a DCE console connection.

  • OS6600-GNI-C2—Provides two fixed 1000BaseT copper connections (uses two RJ-45 connectors). Supports distances up to 100 meters.
  • OS6600-GNI-U2—Provides two MiniGBIC bays that support hot-swappable 1000BASE-X MiniGBIC transceivers.

CONSOLE

EXPANSION/STACKING EXPANSION 25 26 27 28

OK1

PS1

PRI

TEMP

LINK/ACT LINK/ACT LINK/ACT LINK/ACT

OK2

PS2

SEC

FAN SEL

Status and Slot Indicator LEDs For information on the OS6624’s status and slot indicator LEDs, refer to page 2-11.

10/100 Ethernet Ports The OS6624 provides 24 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.

Stacking or Uplink Module Slot The OS6624 provides an additional slot that can accommodate either a stacking module or a Gigabit Ethernet uplink module.

Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks,” for detailed infor- mation.

If you use a Gigabit Ethernet uplink module in this slot, the OS6624 must be used as a stand-alone switch.

A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6624 Front Panel

TM OmniSwitch 6624

Page 24 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6624
Page 24 · click to enlarge
Page 24

OmniSwitch 6624 OmniSwitch 6600 Series Chassis and Hardware Components

Total number of 10/100 Mbps ports per switch

Total number of Gigabit Ethernet ports per switch

4 (for stand-alone switches); 2 (for stacked configurations)

Total number of 10/100 Mbps ports per stack

192 (stack of eight switches)

Total number of Gigabit Ethernet ports per stack

16 (stack of eight switches)

Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate

Current draw Approximately 2.3 Amps

Power Approximately 55 Watts

Total available power supplies 2 (one factory-installed power supply and one optional back up power supply)

Flash memory size 32 MB (30 MB usable)

RAM memory size 128 MB

Overall Width (rack-mount flanges included)

19.125 inches

Chassis Width (rack-mount flanges not included)

17.2 inches

Height 2.65 inches

Height (rack units) 1.5 RU

Chassis Depth 14 inches

Chassis Weight Approximately 12 lbs (13.5 lbs with optional back up power supply installed)

Humidity Operating and storage relative humidity range from 10% to 95% (non-condensing)

Altitude Sea level to 10,000 feet (3 km)

10/100 Ethernet Port Specifications

Standards supported IEEE 802.3u, IAB RFCs 826, 894

Data rate 10 or 100 Mbps (full or half duplex)

Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags

Connections supported 10BaseT hub or device; 100BaseTX hub or device

Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm

Maximum cable distance 100 meters

OS6624 Specifications · Connector type RJ-45

Page 25 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6600-U24
Page 25 · click to enlarge
Page 25

OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6600-U24

OmniSwitch 6600-U24

The OS6600-U24 is a stackable edge/workgroup switch offering 24 fiber 100 Mbps Ethernet SFP ports. The OS6600-U24 can also be equipped with up to four Gigabit Ethernet ports for connections to a high speed backbone or server.

The front panel of the OS6600-U24 chassis contains the following major components:

  • Console (RJ-45) port
  • Stack indicator LED
  • 24 fiber 100 Ethernet SFP ports
  • One slot for OS6600-GNI-U2 (fiber) or OS6600-GNI-C2 (copper) Gigabit Ethernet uplink module
  • One slot for Gigabit Ethernet uplink module as described above or stacking module

The following SFP transceivers are available for the OS6600-U24:

  • SFP-100-LC-MM —100Base FX multimode 62.5/125 and 50/125 micron fiber, supports distances up to 2 km; uses LC connectors.
  • SFP-100-LC-SM15 —100Base FX single mode 9/125 micron fiber, supports distances up to 15 km; uses LC connectors.
  • SFP-100-LC-SM40 —100Base FX single mode 9/125 micron fiber, supports distances up to 40 km; uses LC connectors.
  • SFP-100-MTRJ-MM —100Base FX multimode 62.5/125 and 50/125 micron fiber, supports distances up to 2 km; uses MTRJ connectors.

Refer to the illustration on the following page for more front panel information. For detailed LED descrip- tions, refer to page 2-11. For information on the chassis rear panel, refer to page 2-12.

Page 26 of the Alcatel-Lucent 6624 user manual — EXPANSION/STACKING EXPANSION 25 26 27 28
Page 26 · click to enlarge
Page 26

OmniSwitch 6600-U24 OmniSwitch 6600 Series Chassis and Hardware Components

Console Port The OS6600-U24 front panel provides one RJ-45 port for console connections. Serial console con- nections are used by network administrators for switch management. This female RJ-45connector provides a DCE console connection.

Gigabit Ethernet Uplink Module Slot The OS6600-U24 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:

  • OS6600-GNI-C2—Provides two fixed 1000BaseT copper connections (uses two RJ-45 connectors). Supports distances up to 100 meters.
  • OS6600-GNI-U2—Provides two MiniGBIC bays that support hot-swappable 1000BASE-X MiniGBIC transceivers.

3 5 7 9 11 13 15 17 19 21 23 1

EXPANSION/STACKING EXPANSION 25 26 27 28

CONSOLE

SEL

OK1

PS1

LINK/ACT LINK/ACT 2 24

OK2

PS2 PRI SEC TEMP FAN

2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23

Status and Slot Indicator LEDs For information on the OS6600- U24’s status and slot indicator LEDs, refer to page 2-11.

100 Fiber Ethernet SFP Ports The OS6600-U24 provides 24 fiber 100 Ethernet SFP ports. These ports can use the SFP-100- LC-MM, SFP-100-LC-SM, and SFP-100-MTRJ-MM transceivers in any combination.

Stacking or Uplink Module Slot The OS6600-U24 provides an additional slot that can accommodate either a stacking mod- ule or a Gigabit Ethernet uplink module.

Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks,” for detailed infor- mation.

If you use a Gigabit Ethernet uplink module in this slot, the OS6600-U24 must be used as a stand-alone switch.

A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6600-U24 Front Panel

TM OmniSwitch 6600-U24

Page 27 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6600-U24
Page 27 · click to enlarge
Page 27

OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6600-U24

Total number of 100 Mbps SFP ports per switch

Total number of Gigabit Ethernet ports per switch

4 (for stand-alone switches); 2 (for stacked configurations)

Total number of 100 Mbps SFP ports per stack

192 (stack of eight switches)

Total number of Gigabit Ethernet ports per stack

16 (stack of eight switches)

Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate

Power The OS6600-U24 power supply provides 100 W

Total available power supplies 2 (one factory-installed power supply and one optional back up power supply)

Flash memory size 32 MB (30 MB usable)

RAM memory size 128 MB

Overall Width (rack-mount flanges included)

19.125 inches

Chassis Width (rack-mount flanges not included)

17.2 inches

Height 2.65 inches

Height (rack units) 1.5 RU

Chassis Depth 14 inches

Chassis Weight Approximately 11.56 lbs not including uplink/stacking modules or SFPs (13.06 lbs with optional back up power supply installed)

Humidity Operating and storage relative humidity range from 10% to 95% (non-condensing)

Altitude Sea level to 10,000 feet (3 km)

OS6600-U24 Specifications

Page 28 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6600-U24
Page 28 · click to enlarge
Page 28

OmniSwitch 6600-U24 OmniSwitch 6600 Series Chassis and Hardware Components

100 Mbps Ethernet SFP Port Specifications

Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)

Data rate 100 Mbps (full or half duplex)

Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags

Cable supported SFP-100-LC-MM: 62.5/125 and 50/125 micron multimode fiber SFP-100-LC-SM: 9/125 micron single mode SFP-100-MTRJ-MM: 62.5/125 and 50/125 micron multimode fiber

Optical output power SFP-100-LC-MM-19 to -14 dBm (62.5/125 micron);

-22.5 to -14 dBm (50/125 micron) SFP-100-LC-SM15: -15 to -8 dBm SFP-100-LC-SM40: -5 to 0 dBm SFP-100-MTRJ-MM: -20 to -14 dBm

Input optical power (Receiver sensitivity)

SFP-100-LC-MM: -31 to -14 dBm SFP-100-LC-SM15: -31 to 0dBm SFP-100-LC-SM40: -34 to 0 dBm SFP-100-MTRJ-MM: -31 to -14 dBm

Maximum cable distance SFP-100-LC-MM2 km SFP-100-LC-SM15: 15 km SFP-100-LC-SM40: 40 km SFP-100-MTRJ-MM: 2 km

Connector type SFP · Connections supported 100BaseFX

Page 29 of the Alcatel-Lucent 6624 user manual — EXPANSION
Page 29 · click to enlarge
Page 29

OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6648

OmniSwitch 6648

The OS6648 is a stackable edge/workgroup switch offering 48 10/100 Ethernet ports. The OS6648 can also be equipped with up to four Gigabit Ethernet ports for connections to a high speed backbone or server.

The front panel of the OS6648 chassis contains the following major components:

  • Console (DB-9) port
  • Stack indicator LED
  • 48 10/100 Ethernet ports
  • One slot for OS6600-GNI-U2 (fiber) or OS6600-GNI-C2 (copper) Gigabit Ethernet uplink module
  • One slot for Gigabit Ethernet uplink module as described above or stacking module

Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-11. For information on the chassis rear panel, refer to page 2-12.

Console Port The OS6648 front panel provides one RS232 port for console connections. Serial console connections are used by network administrators for switch management. This female DB-9 con- nector provides a DCE console connection.

Gigabit Ethernet Uplink Module Slot The OS6648 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:

  • OS6600-GNI-C2—Provides two fixed 1000BaseT copper connections (uses two RJ-45 connectors). Supports distances up to 100 meters.
  • OS6600-GNI-U2—Provides two MiniGBIC bays that support hot-swappable 1000BASE-X MiniGBIC transceivers.

CONSOLE

LINK/ACT LINK/ACT

EXPANSION/STACKING

49 50 51 52

EXPANSION

OK1

PS1

PRI

TEMP

LINK/ACT LINK/ACT

OK2

PS2

SEC

FAN

SEL

Status and Slot Indicator LEDs For information on the OS6648’s status and slot indicator LEDs, refer to page 2-11.

10/100 Ethernet Ports The OS6648 provides 48 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.

Stacking or Uplink Module Slot The OS6648 provides an additional slot that can accommodate either a stacking module or a Gigabit Ethernet uplink module.

Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks,” for detailed infor- mation.

If you use a Gigabit Ethernet uplink module in this slot, the OS6648 must be used as a stand-alone switch.

A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6648 Front Panel

TM OmniSwitch 6648

Page 30 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6648
Page 30 · click to enlarge
Page 30

OmniSwitch 6648 OmniSwitch 6600 Series Chassis and Hardware Components

Total number of 10/100 Mbps ports per switch

Total number of Gigabit Ether- net ports per switch

4 (for standalone switches); 2 (for stacked configurations)

Total number of 10/100 Mbps ports per stack

384 (stack of eight switches)

Total number of Gigabit Ether- net ports per stack

16 (stack of eight switches)

Fabric capacity 10.0 Gbps full duplex; 20.0 Gbps aggregate

Current draw Approximately 2.3 Amps

Power Approximately 55 Watts

Total power supplies 2 (one factory-installed power supply and one optional back up power supply)

Flash memory size 32 MB (30 MB usable)

RAM memory size 128 MB

Overall Width (rack-mount flanges included)

19.125 inches

Chassis Width (rack-mount flanges not included)

17.2 inches

Height 2.65 inches

Height (rack units) 1.5 RU

Chassis Depth 14 inches

Chassis Weight Approximately 14 lbs (15.5 lbs with optional back up power supply installed)

Humidity Operating and storage relative humidity range from 10% to 95% (non-condensing)

Altitude Sea level to 10,000 feet (3 km)

10/100 Ethernet Port Specifications

Standards supported IEEE 802.3u, IAB RFCs 826, 894

Data rate 10 or 100 Mbps (full or half duplex)

Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags

Connections supported 10BaseT hub or device; 100BaseTX hub or device

Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm

Maximum cable distance 100 meters

OS6648 Specifications · Connector type RJ-45

Page 31 of the Alcatel-Lucent 6624 user manual — EXPANSION
Page 31 · click to enlarge
Page 31

OmniSwitch 6600 Series Chassis and Hardware Components Status LEDs

Status LEDs

LEDs provide visual status information. These “status lights” are used to indicate conditions such as hardware and software status, primary and back up power supply status, primary and secondary status (stacked configurations), temperature and fan errors, slot number information, link integrity, and data flow.

Refer to the diagram below for detailed information on OmniSwitch 6600 series LED states.

Ethernet Port LEDs Each Ethernet port has a built-in corresponding LED. This LED indicates the link and activity status for each Ethernet port. The LED displays green when a valid Ethernet cable connection exists. Flashes green as data is transmitted or received on the port.

Slot Indicator LED The slot indicator LED is manually configurable and displays the switch’s current slot number in a stacked configuration (i.e., 1 – 8). For detailed information on manually setting the switch’s slot number, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

CONSOLE

LINK/ACT LINK/ACT

EXPANSION/STACKING

49 50 51 52

EXPANSION

OK1

PS1

PRI

TEMP

LINK/ACT LINK/ACT

OK2

PS2

SEC

FAN

SEL

Hardware and Software Status LEDs OK1. Hardware Status. Dis- plays solid green when pow- ered on and the switch has passed hardware diagnostic tests. Displays solid amber when powered on and the switch has failed hardware diagnostic tests.

Power Supply LEDs PS1. Displays solid green when the primary (i.e., factory- installed) power supply status is OK and the power supply is operating normally. Displays solid amber in the unlikely event of a power supply fail- ure.

Stack LEDs PRI. Displays solid green when if the switch is either a stand-alone switch or the pri- mary switch in a stack; other- wise, if the switch status is secondary or idle, this LED is off.

Temperature Management LEDs TEMP. Displays solid green when the switch is operating within the allowed temperature range; displays solid amber if a temperature error occurs (i.e., the switch is operating outside the temperature range).

SEC. Displays solid green if the switch is the secondary switch in a stack; otherwise, this LED is off.

PS2. Displays solid green when the optional redundant power supply status is OK and the power supply is operating normally. Displays solid amber if no redundant power supply is installed or in the unlikely event of a redundant power supply failure.

FAN. Displays solid green when all fans in the fan tray are running at normal speed. Displays solid amber if a fan error occurs (i.e., one or more fans are not running at normal speed).

OK2. Software Status. Blinks green when the switch’s sys- tem management software is operational. Displays solid amber when a system soft- ware failure occurs. Blinks amber when the software is in a transitional state (e.g., when software is being downloaded to the switch).

Front Panel LED Descriptions (OS6648 Shown)

LED Location · TM OmniSwitch 6648

Page 32 of the Alcatel-Lucent 6624 user manual — LAN PWR PORT
Page 32 · click to enlarge
Page 32

Rear Panel OmniSwitch 6600 Series Chassis and Hardware Components

Rear Panel

The rear panel of OmniSwitch 6600 series switches contains the following major components:

  • Factory-installed power supply
  • Back up power supply bay for optional OS66BPS-100A power supply
  • Connector for upcoming inline power supply (not currently supported)
  • Grounding block for type LCD8-10A-L grounding lug

indicates on position; indicates off position.

Ground Lug Connection Unpainted area for Type LCD copper lug attach- ment. Refer to page 2-17 for more information.

Product, Safety, and Compliance Information Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.

100/115/230 V

50/60 Hz, 2/2/1 A MODEL NO: OS-6648

RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

LISTED I.T.E. 5Z71 E164613C

U.S. PATENT NO. 5,394,402

R R

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.

LAN PWR PORT

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.

geprufte Sicherheit Assembled in the US of US and Non-US Components

Redundant Power Supply Bay Slot for optional user-installable OS66BPS-100A back up power supply. For more information on the back up power supply, including technical specifications and installation instructions, refer to “Back Up Power Supply” on page 2-18.

Power Connector Socket Type IEC-320-C13. Supports one 10 amp power cord.

Inline Power Connector Not currently supported. Reserved for future use with upcoming inline power supply.

It is recommended that you use only Alcatel-provided power cords.

OmniSwitch 6600 Series Rear Panel

Power Switch · ! · TUV Rheinland ProductSafety

Page 33 of the Alcatel-Lucent 6624 user manual — }
Page 33 · click to enlarge
Page 33

OmniSwitch 6600 Series Chassis and Hardware Components Mounting the Switch

Mounting the Switch

Airflow Considerations

Be sure that your switch is placed in a well-ventilated, static-free environment. Always allow adequate clearance at the front, rear, and sides of the switch.

The following diagram shows recommended minimum clearances for adequate chassis airflow and access to components at the rear of the chassis—e.g., back up power supply and power switch(es).

Rear Recommended 5 inches minimum at rear of chassis for access to power switch(es) and power cord(s).

}

Sides 2 inches minimum at left and right sides for adequate air- flow. For detailed information on chassis airflow, refer to page 2-47.

Front Recommended 6 inches minimum at front of chassis for access to LEDs and network cables. }

OmniSwitch 6600 Series Chassis Top View

Page 34 of the Alcatel-Lucent 6624 user manual — Installation Options
Page 34 · click to enlarge
Page 34

Mounting the Switch OmniSwitch 6600 Series Chassis and Hardware Components

Installation Options

There are two ways in which the OmniSwitch 6600 series switches can be installed:

  • Tabletop installation
  • Rack-mount installation

Installing the Switch on a Tabletop or Bench

OmniSwitch 6600 series switches can be installed freestanding as tabletop units. Place your switch in a stable, flat, static-free surface.

To install the switch as a tabletop unit, follow the steps below:

1 Position the chassis on the table or bench where it is to be installed.

2 Be sure that adequate clearance has been provided for chassis airflow and access to the front, back, and sides of the switch. For recommended clearances, refer to page 2-13. Also, be sure that you have placed the chassis within reach of all required AC power sources.

3 If you are placing multiple switches in a stacked configuration, carefully stack the remaining switches, one on top or the other. Up to eight switches may be stacked to form a single virtual chassis. Be sure to maintain adequate clearance at the front, rear, left, and right side of all switches. Also, be sure that you have placed all switches in the stack within reach of required AC power sources.

Refer to the important guidelines below before installing the OmniSwitch chassis in a rack.

  • It is recommended that two people install the switch in the rack—one person to hold the chassis and position it in the rack, and a second person to secure the chassis to the rack using attachment screws (not supplied).
  • Alcatel provides two rack-mount flanges with each OmniSwitch 6600 series switch. These flanges support standard 19-inch rack mount installations. These flanges must be attached to the chassis before the switch can be rack mounted.
  • Alcatel does not provide rack-mount screws. Use the screws supplied by the rack vendor.
  • To prevent a rack from becoming top heavy, it is recommended that you install heavier equipment at the bottom of the rack whenever possible.
  • If you are installing the switch in a relay rack, be sure to install and secure the rack per the rack manufacturer’s specifications.
  • Review page 2-13 for important chassis airflow and access recommendations before installing.

Rack-Mounting the Switch

Page 35 of the Alcatel-Lucent 6624 user manual — EXPANSION/STACKING
Page 35 · click to enlarge
Page 35

OmniSwitch 6600 Series Chassis and Hardware Components Mounting the Switch

To rack-mount the switch, follow the steps below:

1 Align the holes in the provided rack-mount flanges with the four threaded holes in the OmniSwitch chassis. These threaded holes are located in the left and right sides of the chassis, near the front panel.

2 Attach the flanges to the chassis using the provided Phillips-head screws. Be sure to tighten each of the screws firmly using a Phillips screwdriver.

Alcatel-Lucent 6624 — Installation Options diagram (page 35)
Fig. 15 · Installation Options

CONSOLE

PRI

TEMP

SEL

PS1

FAN

OK1

SEC

OK2

PS2

Attaching a Rack-Mount Flange

3 After the rack-mount flanges are secured to the chassis, mark the holes on the rack where the switch is to be installed.

4 Lift and position the switch until the rack-mount flanges are flush with the rack post.

5 Align the holes in the flanges with the rack holes that were marked in step 3.

6 Once the holes are aligned, insert a rack mount screw (not provided) through the bottom hole of each flange. Tighten both screws until they are secure.

EXPANSION/STACKING

EXPANSION 49 50 5 1 5 2

Attaching the Switch to the Rack

TM OmniSwitch 6624

Page 36 of the Alcatel-Lucent 6624 user manual — Rack Mounting Stacked Configurations
Page 36 · click to enlarge
Page 36

Mounting the Switch OmniSwitch 6600 Series Chassis and Hardware Components

7 Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws. Be sure that all screws are securely tightened.

Rack Mounting Stacked Configurations

If you are rack mounting multiple switches in a stacked configuration, be sure to place all switches in vertically-adjacent rack positions. This will ensure that all required stacking cables will have adequate length for the installation. For additional instructions on rack mounting a stacked configuration, follow the steps below:

1 Install the rack mount flanges for all switches that are to be included in the stacked configuration, as described on page 2-15. Up to eight switches may be stacked to form a single virtual chassis.

2 Place the next switch in the stack directly on top of the previously installed switch.

3 Align the holes in the flanges with the holes in the rack’s vertical posts.

4 Once the holes are aligned, insert a rack mount screw through the bottom hole of each flange. Tighten both screws until they are secure.

5 Repeat steps 1 through 4 above for all remaining switches.

Page 37 of the Alcatel-Lucent 6624 user manual — Grounding the Chassis
Page 37 · click to enlarge
Page 37

OmniSwitch 6600 Series Chassis and Hardware Components Power Cords

Power Cords

Because the power cord is the power supply’s main disconnect device, it should be plugged into an easily accessible outlet. In the event that your power cord is lost or damaged, refer to the specifications below.

Specifications

The power cord to be used with 115-Volt configuration is a minimum type SJT (SVT) 18/3, rated at 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates in a NEMA 5-15P plug.

The power cord to be used with 230-Volt configuration is minimum type SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates as required by the country where it will be installed.

European cords must be Harmonized (HAR) type. Refer to the information below for power plug types by region:

North America NEMA 5-15-P (US), C22.2, No. 42 (Canada)

United Kingdom / Ireland BS 1,363

Switzerland / Liechtenstein SEV 1011

Denmark / Greenland SRAF 1,962 / D816 / 87

Grounding the Chassis

The switch has two threaded holes for grounding screws located on the back of the chassis. These holes use 10-32 screws and are approximately one inch apart. These holes are surrounded by a small paint-free rectangular area, which provides metal-to-metal contact for a ground connection.

Use this connector to supplement the ground provided by the AC power cord. To do so, install a Panduit Grounding Lug (type LCD8-10A-L) using 8AWG copper conductors to the paint-free rectangular area. Be sure to use a crimping tool.

Show 7 more labels / short text on this page
Power Cord Types · Europe CEE 7/7 · Japan JIS 8,303 · Australia AS 3,112 · India BS 546 · Italy CIE 2,316 · Argentina AR1-10P
Page 38 of the Alcatel-Lucent 6624 user manual — Power Supply Redundancy
Page 38 · click to enlarge
Page 38

Back Up Power Supply OmniSwitch 6600 Series Chassis and Hardware Components

Back Up Power Supply

OmniSwitch 6600 series switches provide one factory-installed power supply per chassis. Each switch also provides one bay for the optional OS66BPS-100A back up power supply. The back up power supply bay is located on the chassis rear panel (see page 2-12 for details).

For information on installing a back up power supply, refer to page 2-20. For information on removing a back up power supply, refer to page 2-22.

Power Connector Socket. Type IEC-320-C13. Supports one 10 amp power cord.

Product, Safety, and Compliance Information. Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.

It is recommended that you use Alcatel-provided power cords.

!

50/60 Hz, 2/2/1 A 100/115/230 V

Power Switch.

indicates on position; indicates off position.

Back Up Power Supply Front Panel

Power Supply Redundancy

After a back up power supply is installed, the primary (factory-installed) power supply continues to take on the full power load for switch operations. Meanwhile, the back up power supply operates in active standby mode. If the primary power supply fails unexpectedly, the back up power supply automatically takes up the full power load without disrupting the switch.

Back Up Power Supply Specifications

Input Voltage 85 to 250 VAC

Input Frequency 47 to 63 Hz

Efficiency 75% measured at 115 VAC

Temperature Operating0 to +50 Celsius Non-Operating: - 40 to +85 Celsius

Relative Humidity 5% to 95% non -condensing

Altitude 10,000 feet @ +32 Celsius

Page 39 of the Alcatel-Lucent 6624 user manual — LAN PWR PORT
Page 39 · click to enlarge
Page 39

OmniSwitch 6600 Series Chassis and Hardware Components Back Up Power Supply

Redundant AC Circuit Recommendation

When a back up power supply is installed, it is recommended that the AC source connected to the back up power supply resides on a separate circuit from the primary power supply. With redundant AC, if a single circuit fails, the switch’s back up power supply (on a separate circuit) will likely be unaffected and the switch can continue operating.

The diagram below shows a simple redundant AC circuit scenario for OS6600 series switches.

Back Up Power Supply

Factory-Installed (Primary) Power Supply

Both the primary and redundant power supplies are installed in the chassis, providing power supply redundancy.

100/115/230 V

LISTED I.T.E. 5Z71 E164613C !

50/60 Hz, 2/2/1 A MODEL NO: OS-6648

RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

U.S. PATENT NO. 5,394,402

50/60 Hz, 2/2/1 A 100/115/230 V

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.

R R

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.

geprufte Sicherheit Assembled in the US of US and Non-US Components

LAN PWR PORT

Each power supply is connected to an AC source on a separate circuit.

Back Up Power Supply

Factory-Installed (Primary) Power Supply In the event of a failure at circuit 1 (for example, a tripped circuit breaker), the redundant power supply plugged into the grounded AC outlet on circuit 2 allows switch operations to continue.

!

LISTED I.T.E. 5Z71 E164613C !

50/60 Hz, 2/2/1 A MODEL NO: OS-6648

RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

U.S. PATENT NO. 5,394,402

100/115/230 V

50/60 Hz, 2/2/1 A 100/115/230 V

R R

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.

LAN PWR PORT

geprufte Sicherheit Assembled in the US of US and Non-US Components

OmniSwitch 6600 Series Redundant AC Circuit Example

Show 8 more labels / short text on this page
AC Circuit 1 · ! · TUV Rheinland ProductSafety · AC Circuit 2 · AC Circuit 1 · ! · TUV Rheinland ProductSafety · AC Circuit 2
Page 40 of the Alcatel-Lucent 6624 user manual — Hot Swapping
Page 40 · click to enlarge
Page 40

Back Up Power Supply OmniSwitch 6600 Series Chassis and Hardware Components

Installing a Back Up Power Supply

You can add a back up power supply to the chassis at any time without disturbing the switch’s network functions. You are not required to power down the switch.

Hot Swapping

Hot swapping a back up power supply refers to the action of replacing the unit while the switch is operat- ing. Again, because it is a back up (i.e., redundant component), you are not required to power off the switch’s primary power source.

To add the optional back up power supply to the chassis, follow the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the back up power supply.

1 Locate the back up power supply bay. The back up power supply bay is located at the switch’s rear panel. Refer to page 2-12 for a view of the chassis rear panel.

2 If there is a blank cover panel installed at the back up power supply bay, uninstall it by removing the two Phillips attachment screws. After the attachment screws have been removed, carefully pry the blank cover panel out and away from the chassis. Set the cover panel and attachment screws aside.

3 To avoid attempting to install the back up power supply upside down, orient the unit as shown in the diagram below.

50/60 Hz, 2/2/1 A 100/115/230 V

Orient the back up power supply with the vent side up, as shown.

Orienting the Back Up Power Supply

Top · !

Page 41 of the Alcatel-Lucent 6624 user manual — R R
Page 41 · click to enlarge
Page 41

OmniSwitch 6600 Series Chassis and Hardware Components Back Up Power Supply

4 Grasp the front portion of the power supply and carefully insert the rear of the casing into the power supply bay. Slide the power supply back until the unit meets the connector in the chassis power supply bay.

Assembled in the US of US and Non-US Components

ÉRIEL BROUILLEUR DU CANADA

Alcatel-Lucent 6624 — ÉRIEL BROUILLEUR DU CANADA diagram (page 41)
Fig. 16

50/60 Hz, 2/2/1 A 100/115/230 V

U.S. PATENT NO. 5,394,402

50/60 Hz, 2/2/1 A 100/115/230 V

LAN PWR PORT

geprufte Sicherheit Assembled in the US of US and Non-US Components

R R

LISTED I.T.E. 5Z71 E164613C

ÉRIEL BROUILLEUR DU CANADA.

50/60 Hz, 2/2/1 A 100/115/230 V

Inserting the Back Up Power Supply

5 Continue sliding the power supply back until the front panel is flush with the rear panel of the chassis. Do not force the power supply into the bay. Otherwise you can damage the connectors.

6 Tighten the two captive screws, located at the left and right sides of the power supply’s front panel. Be sure not to overtighten the captive screws. If you use a screwdriver, the torque used to tighten the screws must not exceed 2.3 inch pounds.

Assembled in the US of US and Non-US Components !

MODEL NO: OS RATING: 100-240V THIS DEVICE COMPLIES WITH IS SUBJECT TO THE FOLLOWING T (1) THIS DEVICE MAY NOT CAUSE HAR (2) THIS DEVICE MUST ACCEPT ANY INTER INTERFERENCE THAT MAY CAUSE UNDESIRED

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIRE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULAT

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA

50/60 Hz, 2/2/1 A 100/115/230 V

Tightening the Captive Screws

7 Verify that the power supply’s on/off switch is in the off ( O ) position.

8 Connect the power supply cord (provided) into an easily accessible power source.

Show 4 more labels / short text on this page
! · ! · TUV Rheinland ProductSafety · !
Page 42 of the Alcatel-Lucent 6624 user manual — LAN PWR PORT
Page 42 · click to enlarge
Page 42

Back Up Power Supply OmniSwitch 6600 Series Chassis and Hardware Components

Removing a Back Up Power Supply

1 Before removing the back up power supply, make sure that the power switch is in the off ( O ) position.

2 Unplug the power cord from the AC power source, as well as from the socket located on the power supply’s front panel.

3 Loosen the two captive screws, located at the left and right sides of the power supply’s front panel. If necessary, use a flat-blade screwdriver to loosen the screws.

MODEL NO: OS RATING: 100-240V THIS DEVICE COMPLIES WITH IS SUBJECT TO THE FOLLOWING T (1) THIS DEVICE MAY NOT CAUSE HAR (2) THIS DEVICE MUST ACCEPT ANY INTER INTERFERENCE THAT MAY CAUSE UNDESIRED

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIRE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULAT

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA

Assembled in the US of US and Non-US Components !

50/60 Hz, 2/2/1 A 100/115/230 V

Loosening the Captive Screws

4 Once the captive screws are completely disengaged, grasp both captive screws and slowly pull the power supply out of the power supply bay.

Assembled in the US of US and Non-US Components

ÉRIEL BROUILLEUR DU CANADA

Alcatel-Lucent 6624 — ÉRIEL BROUILLEUR DU CANADA diagram (page 42)
Fig. 17

50/60 Hz, 2/2/1 A 100/115/230 V

U.S. PATENT NO. 5,394,402

50/60 Hz, 2/2/1 A 100/115/230 V

LAN PWR PORT

R R

LISTED I.T.E. 5Z71 E164613C

geprufte Sicherheit Assembled in the US of US and Non-US Components

ÉRIEL BROUILLEUR DU CANADA.

50/60 Hz, 2/2/1 A 100/115/230 V

Removing the Back Up Power Supply

5 Store the power supply in a secure, static-free location. Placing the unit in an anti-static bag is recommended.

Show 4 more labels / short text on this page
! · ! · TUV Rheinland ProductSafety · !
Page 43 of the Alcatel-Lucent 6624 user manual — Viewing Primary and Back Up Power Supply Status
Page 43 · click to enlarge
Page 43

OmniSwitch 6600 Series Chassis and Hardware Components Back Up Power Supply

Blank Cover Panel Requirement

If you are not replacing the back up power supply being removed, be sure to install a blank cover panel (supplied with your switch) over the empty power supply bay. To install a blank cover panel, follow the steps below.

1 Place the blank cover panel over the empty power supply bay and insert two Phillips screws (also supplied with the switch) through the panel and into the threaded holes in the chassis.

2 Once the screws are inserted, fasten the panel to the chassis by tightening the screws. Be sure not to overtighten the screws.

Viewing Primary and Back Up Power Supply Status

The switch constantly monitors primary and back up power supply operation. If either power supply unex- pectedly shuts down, the switch sends out a trap to the user and the PS1 and/or PS2 LEDs on the chassis front panel turn amber.

To check the number of power supplies currently operating, and the status of each power supply, use the show power command. For example:

-> show power Power Supplies in chassis 8 PS Operational Status + PS-1 UP PS-2 NOT PRESENT

The primary (i.e., factory-installed) power supply is listed as PS-1 in the show power command output. The back up power supply is listed as PS-2. In the example above, there is no back up power supply installed in the chassis.

Page 44 of the Alcatel-Lucent 6624 user manual — No Slot Number is Specified
Page 44 · click to enlarge
Page 44

Back Up Power Supply OmniSwitch 6600 Series Chassis and Hardware Components

Viewing Power Supply Status for Stacked Configurations

When entering the show power command on the primary switch in a stacked configuration, you can either enter only the show power syntax or you can specify a specific slot number. For more information, refer to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, power supply information for only the correspond- ing switch displays. For example:

-> show power 2 Power Supplies in chassis 2 PS Operational Status + PS-1 UP PS-2 NOT PRESENT

In the example above, power supply status for the switch operating in slot 2 displays. No back up power supply is installed in the slot 2 chassis (or the back up power supply is powered off).

No Slot Number is Specified

If you do not enter a slot number, power supply information for all switches in the stack displays. For example:

-> show power Power Supplies in chassis 1 PS Operational Status + PS-1 UP PS-2 UP

Power Supplies in chassis 2 PS Operational Status + PS-1 UP PS-2 NOT PRESENT

The example above shows the power supply status for a stack consisting of two switches. A back up power supply is present and running in the switch operating in slot 1; no back up power supply is installed in the switch operating in slot 2 (or the unit is powered off).

More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Page 45 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 45 · click to enlarge
Page 45

OmniSwitch 6600 Series Chassis and Hardware Components Gigabit Ethernet Uplink Modules

Gigabit Ethernet Uplink Modules

OmniSwitch 6624, 6600-U24, and 6648 switches support the following Gigabit Ethernet uplink modules:

  • OS6600-GNI-C2 Copper Gigabit Ethernet Uplink Module
  • OS6600-GNI-U2 Fiber Gigabit Ethernet Uplink Module

OS6600-GNI-U2

The OS6600-GNI-U2 Gigabit Ethernet uplink module provides two MiniGBIC bays that support 1000BASE-X MiniGBIC transceivers. Cable options include multimode, single mode, and long-reach single mode fiber. The OS6600-GNI-U2 supports bi-directional wire speed switching on all ports simulta- neously. Also, because it supports any combination of the three MiniGBIC options, this module offers a flexible solution for various customer requirements.

This uplink module may be used to support multiple uplinks from the wiring closet switch to the Gigabit Ethernet backbone links in the core. With the two MiniGBIC ports provided by the OS6600-GNI-U2, up to 16 Gigabit Ethernet ports can be supported in a fully-loaded stacked configuration.

MiniGBIC Slots The OS6600-GNI-U2 provides two universal MiniGBIC ports for hot-pluggable MiniGBIC fiber transceivers. Mini- GBIC options include multimode, single mode, and long- reach single mode fiber. Refer to “Mini Gigabit Interface Converters (MiniGBICs)” on page 2-33 for more informa- tion.

LINK/ACT LINK/ACT

LINK/ACT LEDs Each MiniGBIC port has a built-in corresponding LED. This LED indicates the link and activity status for each MiniGBIC installed. The LED displays green when a valid cable connection exists. Flashes green as data is transmitted or received on the interface.

OS6600-GNI-U2 Gigabit Ethernet Uplink Front Panel

Page 46 of the Alcatel-Lucent 6624 user manual — Gigabit Ethernet Uplink Modules
Page 46 · click to enlarge
Page 46

Gigabit Ethernet Uplink Modules OmniSwitch 6600 Series Chassis and Hardware Components

OS6600-GNI-U2 Uplink Module Specifications

Number of ports 2 (hot-pluggable)

Power Approximately 5 Watts

Standards supported 802.3z; 1000Base-SX, 1000Base-LX

Data rate 1 Gigabit per second (full duplex)

Connector type MiniGBIC

Page 47 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 47 · click to enlarge
Page 47

OmniSwitch 6600 Series Chassis and Hardware Components Gigabit Ethernet Uplink Modules

OS6600-GNI-C2

The OS6600-GNI-C2 Gigabit Ethernet uplink module provides two fixed 1000BASE-T (copper) connec- tions. This uplink module supports bi-directional wire speed switching on all ports simultaneously and offers a flexible solution for Gigabit Ethernet-over-copper applications.

The OS6600-GNI-C2 uplink module supports multiple uplinks from the wiring closet to Gigabit Ethernet backbone links in the core. With the two RJ-45 ports on this uplink module, up to 16 Gigabit Ethernet ports can be supported in a fully loaded stackable configuration.

Copper Gigabit Ethernet Ports The OS6600-GNI-C2 provides two fixed 1000BASE-T (copper) connections. The port type is RJ-45.

LINK/ACT LINK/ACT

LINK/ACT LEDs Each RJ-45 port has a built-in corresponding LED. This LED indi- cates the link and activity status for each Gigabit Ethernet copper port. The LED displays green when a valid cable connection exists. Flashes green as data is transmitted or received on the interface.

OS6600-GNI-C2 Gigabit Ethernet Uplink Front Panel

OS6600-GNI-C2 Uplink Module Specifications

Number of ports 2 twisted-pair

Power Approximately 9 Watts

Standards supported 802.3z, 802.3ab; 1000Base-T

Data rate 1 Gigabit per second (full duplex)

Connections supported 1000BaseT connection to backbone or server

Cable supported 1000BaseT unshielded twisted-pair (UTP), Category 5e

Maximum cable distance 100 meters, Category 5

Connector type RJ-45

Page 48 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 48 · click to enlarge
Page 48

Gigabit Ethernet Uplink Modules OmniSwitch 6600 Series Chassis and Hardware Components

Stacking Module

Stacking modules are used to connect OmniSwitch 6624, 6600-U24, and 6648 switches in a stack. The stack acts as a virtual chassis, with switches serving as primary and secondary management modules and Network Interface (NI) modules. For detailed information, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

For information on installing stacking modules, refer to page 2-29. For information on removing stacking modules, refer to page 2-31. For important installation restrictions, refer to the chassis front panel informa- tion on pages 2-3 and 2-9, as well as “Installing Uplink and Stacking Modules” on page 2-29.

HSSDC Stacking Connectors The stacking module provides two dedicated High Speed Serial Data Connectors (HSSDCs). These connectors are used to connect OS6624/ OS6600-U24/OS6648 switches in a stack. For detailed information on stacks, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

LINK/ACT LINK/ACT

LINK/ACT LEDs Each stacking connector has a built-in corresponding LED. This LED indicates the link and activity status for each connector. The LED dis- plays green when a valid cable connection exists. Flashes green as data is being transmitted to, or received from, the adjacent switch in the stack.

Stacking Module Front Panel

Number of ports 2

Power Approximately 8 Watts

Data Speed 1 Gigabit per second per stacking cable installed

Connector type High Speed Serial Data Connector (HSSDC)

Chassis port locations 27 and 28 (OS6624 and OS6600-U24); 51 and 52 (OS6648)

Hot-swappable with other module types? No

Stacking Module Specifications

Page 49 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 49 · click to enlarge
Page 49

OmniSwitch 6600 Series Chassis and Hardware Components Installing Uplink and Stacking Modules

Installing Uplink and Stacking Modules

Before installing uplink or stacking modules, refer to the important guidelines listed below:

  • Stacking modules can only be installed in the far-right module slot. This slot is labeled EXPANSION/ STACKING and contains port positions 27 and 28 (OS6624/6600-U24) or 51 and 52 (OS6648).
  • Do not attempt to install stacking modules at the EXPANSION slot at port positions 25 and 26 (OS6624/OS6600-U24) or 49 and 50 (OS6648).
  • OS6600-GNI-U2 and OS6600-GNI-C2 uplink modules can be installed in either slot location. However, if you install a Gigabit Ethernet uplink module in the EXPANSION/STACKING slot, the switch must be used as a stand-alone unit.
  • Port numbers are clearly marked on the OS6624, OS6600-U24, and OS6648 chassis front panels.
  • Stacking modules cannot be hot swapped at any time.

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the uplink or stack- ing module.

1 If there is a blank cover panel installed over the uplink or stacking module slot position, uninstall it by removing the two Phillips attachment screws. After the attachment screws have been removed, carefully pry the blank cover panel out and away from the chassis. Set the cover panel and attachment screws aside.

2 Holding the uplink or stacking module by the front panel, carefully slide the circuit board into the card guide located in the chassis slot.

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

Inserting the Uplink or Stacking Module

Page 50 of the Alcatel-Lucent 6624 user manual — Installing Uplink and Stacking Modules
Page 50 · click to enlarge
Page 50

Installing Uplink and Stacking Modules OmniSwitch 6600 Series Chassis and Hardware Components

Alcatel-Lucent 6624 — Installing Uplink and Stacking Modules diagram (page 50)
Fig. 18 · Installing Uplink and Stacking Modules

3 Slide the module back until the backplane connector is inserted in the chassis backplane; the module’s front panel should be flush with the front of the chassis. Do not force the module into the slot. Otherwise you can damage the connectors.

4 Once the module is firmly seated and flush with the chassis front panel, secure the module by tighten- ing the two captive screws. Be sure not to overtighten the captive screws. If you use a screwdriver, the torque used to tighten the screws must not exceed 2.3 inch pounds.

Page 51 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 51 · click to enlarge
Page 51

OmniSwitch 6600 Series Chassis and Hardware Components Removing Uplink and Stacking Modules

Removing Uplink and Stacking Modules

To remove an uplink or stacking module from the chassis, follow the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the uplink or stack- ing module.

1 Loosen the two captive screws, located at the left and right sides of the module’s front panel. If neces- sary, use a Phillips screwdriver to loosen the screws.

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

Loosening the Captive Screws

Page 52 of the Alcatel-Lucent 6624 user manual — Blank Cover Panel Requirement
Page 52 · click to enlarge
Page 52

Removing Uplink and Stacking Modules OmniSwitch 6600 Series Chassis and Hardware Components

2 Once the captive screws are completely disengaged, grasp both captive screws and slowly pull the module out of the slot.

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

EXPANSION 49 50 5 1 5 2

EXPANSION/STACKING

LINK/ACT LINK/ACT

CONSOLE

OK1

PS1

PS2

PRI

SEC

TEMP

FAN

SEL

OK2

3 Store the module in a secure, static-free location. Placing the module in an anti-static bag is recom- mended.

Blank Cover Panel Requirement

If you are not replacing the uplink or stacking module being removed, be sure to install a blank cover panel (supplied with your switch) over the empty module slot. To install a blank cover panel, follow the steps below.

1 Place the blank cover panel over the empty slot and insert two Phillips screws (also supplied with the switch) through the panel and into the threaded holes in the chassis.

2 Once the screws are inserted, fasten the panel to the chassis by tightening the screws. Be sure not to overtighten the screws.

TM OmniSwitch 6624 · Removing the Module

Page 53 of the Alcatel-Lucent 6624 user manual — TX RX
Page 53 · click to enlarge
Page 53

OmniSwitch 6600 Series Chassis and Hardware Components Mini Gigabit Interface Converters (MiniGBICs)

Mini Gigabit Interface Converters (MiniGBICs)

Mini Gigabit Interface Converters (MiniGBICs) are fiber-based Gigabit Ethernet transceivers for use with OS6600-GNI-U2 uplink modules on OmniSwitch 6624, 6600-U24, and 6648 switches. MiniGBICs are interchangeable and hot-swappable, thus providing users an easy, flexible solution for adapting OS6600 series switches to different physical interfaces types.

Alcatel offers three MiniGBIC options:

  • MiniGBIC-SX: 1000BASE-SX short-haul
  • MiniGBIC-LX: 1000BASE-LX long-haul
  • MiniGBIC-LH-70: 1000BASE-LH extra long-haul

All MiniGBIC types support bi-directional wire-speed switching. For additional technical specifications on all three MiniGBIC types, refer to page 2-34. For information on installing MiniGBICs, refer to page 2-35.

TX RX

Mini Gigabit Interface Converter (MiniGBIC)

Page 54 of the Alcatel-Lucent 6624 user manual — MiniGBIC Specifications
Page 54 · click to enlarge
Page 54

Mini Gigabit Interface Converters (MiniGBICs) OmniSwitch 6600 Series Chassis and Hardware Components

MiniGBIC Specifications

Standards supported 802.3z, 1000Base-SX

Connections supported 1000Base-SX connection to backbone or server

Fiber optic cable supported Multimode

Source type 850 nm

Output optical power -9.5 to 0 dBm

Input optical power -17 to 0 dBm

Cable distances 220 m

Standards supported 802.3z, 1000Base-LX

Connections supported 1000Base-LX connection to backbone or server

Fiber optic cable supported Single mode

Source type 1310 nm

Output optical power -11 to -3 dBm

Input optical power -19 to -3 dBm (intermediate reach single mode)

Cable distances 10 km

Standards supported 802.3z, 1000Base-LH70

Connections supported 1000Base-LH70 connection to backbone or server

Fiber optic cable supported Single mode

Source type 1550 nm

Output optical power 0 to +5 dBm

Input optical power -23 to -3 dBm

Cable distances Long reach single mode fiber 70 km (up to 100 km using premium single mode fiber or dispersion-shifted single mode fiber)

Show 6 more labels / short text on this page
MiniGBIC-SX Technical Specifications · Connector type LC · MiniGBIC-LX Technical Specifications · Connector types LC · MiniGBIC-LH-70 Technical Specifications · Connector types LC
Page 55 of the Alcatel-Lucent 6624 user manual — EXPANSION 49 50 5 1 5 2
Page 55 · click to enlarge
Page 55

OmniSwitch 6600 Series Chassis and Hardware Components Installing MiniGBICs

Installing MiniGBICs

Each OS6600-GNI-U2 uplink module supports up to two MiniGBICs on OmniSwitch 6624, 6600-U24, and 6648 switches. These MiniGBICs are packaged separately and therefore are not factory-installed. You can install the MiniGBIC(s) by following the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the MiniGBIC, as well as the switch and uplink module.

1 Holding the MiniGBIC by its sides, carefully slide it into the desired MiniGBIC slot in the OS6600- GNI-U2 module on OmniSwitch 6624, 6600-U24, and 6648 switches, as shown.

EXPANSION/STACKING

5 1 5 2

EXPANSION 49 50 5 1 5 2

EXPANSION/STACKING

CONSOLE

OK1

PS1

PRI

SEC

TEMP

FAN

SEL

OK2

PS2

Inserting the MiniGBIC (OS6648 Shown)

TM OmniSwitch 6624

Page 56 of the Alcatel-Lucent 6624 user manual — Removing MiniGBICs
Page 56 · click to enlarge
Page 56

Removing MiniGBICs OmniSwitch 6600 Series Chassis and Hardware Components

2 Push the MiniGBIC into the slot until it is completely inserted and securely seated in the OS6600-GNI-U2 module on OmniSwitch 6624, 6600-U24, and 6648 switches, as shown.

EXPANSION/STACKING

5 1 5 2

Installed MiniGBIC (OS6648 Shown)

Removing MiniGBICs

MiniGBICs modules can be hot swapped. You are not required to power off the switch before removing a MiniGBIC from the uplink module. To remove a MiniGBIC from the uplink module, follow the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the MiniGBIC, as well as the switch and uplink module.

1 On OmniSwitch 6624, 6600-U24, and 6648 switches only, make sure that the captive screws on the OS6600-GNI-U2 are tightened and the module is securely installed in the chassis.

2 There is a small removal handle at the front of the MiniGBIC transceiver. Carefully lift this handle; then, grasp the handle and carefully pull the MiniGBIC from the module.

3 Store the MiniGBIC in a secure, static-free location. Placing the MiniGBIC in an anti-static bag is recommended.

Page 57 of the Alcatel-Lucent 6624 user manual — 100 Mbps SFPs (OS6600-U24)
Page 57 · click to enlarge
Page 57

OmniSwitch 6600 Series Chassis and Hardware Components 100 Mbps SFPs (OS6600-U24)

100 Mbps SFPs (OS6600-U24)

Small Form Pluggable (SFP) modules are fiber-based 100 Mbps Ethernet transceivers for use with ports 1 through 24 on OmniSwitch 6600-U24. SFPs are interchangeable and hot-swappable, thus providing users an easy, flexible solution for adapting OS6600-U24 switches to different physical interfaces types.

Alcatel offers four SFP options:

  • SFP-100-LC-MM: 100BaseFM short haul, LC connector
  • SFP-100-LC-SM15: 100BaseFS intermediate haul, LC connector
  • SFP-100-LC-SM40: 100BaseFS long haul, LC connector
  • SFP-100-MTRJ-MM: 100BaseFM short haul, MTRJ connector

All SFP types support bi-directional wire-speed switching. For additional technical specifications on all four SFP types, refer to page 2-38. For information on installing SFPs, refer to page 2-40.

SFP Module

Page 58 of the Alcatel-Lucent 6624 user manual — 100 Mbps SFP Specifications
Page 58 · click to enlarge
Page 58

100 Mbps SFPs (OS6600-U24) OmniSwitch 6600 Series Chassis and Hardware Components

100 Mbps SFP Specifications

Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)

Fiber optic cable supported multimode fiber

Source type 62.5/125 and 50/125 micron

Output optical power -19 to -14 dBm (62.5/125); -22.5 to -14 dBm (50/125)

Input optical power (Receiver sensitivity)

-31 to -14 dBm

Cable distances 2 km

Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)

Fiber optic cable supported single mode fiber

Source type 9/125 micron

Output optical power -15 to -8 dBm

Input optical power (Receiver sensitivity)

-31 to 0 dBm

Cable distances 15 km

Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)

Fiber optic cable supported single mode fiber

Source type 9/125 micron

Output optical power -5 to 0 dBm

Input optical power (Receiver sensitivity)

-34 to 0 dBm

Cable distances 40 km

Show 9 more labels / short text on this page
SFP-100-LC-MM Technical Specifications · Connector type LC · Connections supported 100BaseFM · SFP-100-LC-SM15 Technical Specifications · Connector types LC · Connections supported 100BaseFS · SFP-100-LC-SM40 Technical Specifications · Connector types LC · Connections supported 100BaseFS
Page 59 of the Alcatel-Lucent 6624 user manual — 100 Mbps SFP Specifications
Page 59 · click to enlarge
Page 59

OmniSwitch 6600 Series Chassis and Hardware Components 100 Mbps SFPs (OS6600-U24)

Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)

Fiber optic cable supported multimode fiber

Source type 62.5/125 and 50/125 micron

Output optical power -20 to -14 dBm (multimode)

Input optical power (Receiver sensitivity)

-31 to -14 dBm

Cable distances 2 km

SFP-100-MTRJ-MM Technical Specifications · Connector types MTRJ · Connections supported 100BaseFM

Page 60 of the Alcatel-Lucent 6624 user manual — Installing SFPs (OS6600-U24)
Page 60 · click to enlarge
Page 60

Installing SFPs (OS6600-U24) OmniSwitch 6600 Series Chassis and Hardware Components

Installing SFPs (OS6600-U24)

OmniSwitch 6600-U24 switches support up to 24 (twenty-four) 100 Mbps Small Form Pluggable (SFP) modules. These SFPs are packaged separately and therefore are not factory-installed. You can install the SFP(s) by following the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the SFP, as well as the switch and uplink module.

1 Align the transceiver with the transceiver slot on the OS6600-U24 as shown.

2 Holding the SFP by its sides, carefully slide it into the desired SFP slot (ports 1–24) until it clicks into place; this is an indication that the connectors are firmly seated.

Inserting the SFP

Page 61 of the Alcatel-Lucent 6624 user manual — Removing SFPs (OS6600-U24)
Page 61 · click to enlarge
Page 61

OmniSwitch 6600 Series Chassis and Hardware Components Removing SFPs (OS6600-U24)

Removing SFPs (OS6600-U24)

SFPs modules can be hot swapped. You are not required to power off the switch before removing a SFP from the uplink module. To remove a SFP from the uplink module, follow the steps below:

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the SFP, as well as the switch and uplink module.

1 On some SFPs there is a small removal handle at the front of the SFP transceiver. Carefully lift this handle.

On other SFPs there is an ejector button located just below the transceiver port. Push this button to disengage the SFP.

2 Grasp the SFP and carefully pull it from the OS6600-U24.

3 Store the SFP in a secure, static-free location. Placing the SFP in an anti-static bag is recommended.

Page 62 of the Alcatel-Lucent 6624 user manual — Viewing Chassis Temperature Status
Page 62 · click to enlarge
Page 62

Temperature Management OmniSwitch 6600 Series Chassis and Hardware Components

Temperature Management

The operating temperature of your switch is an important factor in its overall health. In order to avoid a temperature-related system failure, your switch must always run at an operating temperature between 0 and 45 degrees Celsius (32 to 113 degrees Fahrenheit).

To avoid chassis over-temperature conditions, follow these important guidelines:

1 Be sure that your switch is installed in a well-ventilated environment. To ensure adequate airflow, leave at least two inches of clearance at the left and right sides.

2 If your switch chassis is not fully populated with uplink or stacking modules, be sure that blank cover panels are installed at empty slot positions at all times. Blank cover panels help regulate airflow and thus regulate the overall operating temperature in the switch. Refer to page 2-48 for more information.

Viewing Chassis Temperature Status

As with power supply status, the switch constantly monitors the chassis temperature. If a temperature error has occurred, the switch sends out a trap to the user and the TEMP LED on the chassis front panel displays amber.

To check the current chassis temperature status, use the show temperature command. For example:

Temperature for chassis 1 Hardware Board Temperature (deg C) = 39, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77

In the example above, the switch’s current temperature is 39 degrees Celsius. The switch is operating under the upper temperature threshold, which is 57 degrees Celsius.

-> show temperature

Page 63 of the Alcatel-Lucent 6624 user manual — No Slot Number is Specified
Page 63 · click to enlarge
Page 63

OmniSwitch 6600 Series Chassis and Hardware Components Temperature Management

Viewing Temperature Status for Stacked Configurations

When entering the show temperature command on the primary switch in a stacked configuration, you can either enter only the show temperature syntax or you can specify a specific slot number. For more information, refer to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, chassis temperature information for only the corre- sponding switch displays. For example:

-> show temperature 3

Temperature for chassis 3 Hardware Board Temperature (deg C) = 43, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77

The example above shows chassis temperature information for the switch operating in slot position 3 only. The current temperature is 43 degrees Celsius. The switch is operating under the upper temperature thresh- old.

No Slot Number is Specified

If you do not enter a slot number, fan status information for all switches in the stack displays. For example:

Temperature for chassis 1 Hardware Board Temperature (deg C) = 40, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77

Temperature for chassis 2 Hardware Board Temperature (deg C) = 31, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77

The example above shows chassis temperature information for a stack consisting of two switches. The current temperature of the switch operating in slot position 1 is 40 degrees Celsius; the current tempera- ture of the switch operating in slot 2 is 31 degrees Celsius. Both switches are operating under the upper temperature threshold.

More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

-> show temperature

Page 64 of the Alcatel-Lucent 6624 user manual — Danger Threshold
Page 64 · click to enlarge
Page 64

Temperature Management OmniSwitch 6600 Series Chassis and Hardware Components

Temperature Errors

The switch monitors the chassis ambient air temperature at all times via an onboard sensor. If an over- temperature condition occurs, there are two different levels of error severity:

  • Warning threshold has been exceeded
  • Danger threshold has been exceeded

Warning Threshold

If the temperature exceeds the switch’s user-configurable warning threshold, the switch sends out a trap. Traps are printed to the console in the form of text error messages. The chassis TEMP LED also displays amber, indicating an error. (Refer to page 2-11 for status LED locations and descriptions.)

When the warning threshold has been exceeded, switch operations remain active. However, it is recom- mended that immediate steps be taken to address the over-temperature condition.

Addressing warning threshold temperature conditions may include:

  • Checking for a chassis air flow obstruction
  • Checking the ambient room temperature
  • Checking the fan status using the show fan command. See page 2-45 for more information.
  • Verifying that the warning threshold has not been manually set to an otherwise common or acceptable ambient temperature—for example, 31 degrees Centigrade. (The default warning threshold is 57 degrees Celsius. This value may be configured using the temp-threshold command. The current warning threshold may be viewed using the show temperature command.)

Danger Threshold

If the chassis ambient air temperature rises above the switch’s danger threshold of 80 degrees Centigrade, the switch will power off. The danger threshold is factory-set and cannot be configured by the user.

Addressing danger threshold temperature conditions may include:

  • Checking for a chassis air flow obstruction
  • Checking the ambient room temperature
  • Checking the fan status using the show fan command. See page page 2-45 for more information.
Page 65 of the Alcatel-Lucent 6624 user manual — A Slot Number is Specified
Page 65 · click to enlarge
Page 65

OmniSwitch 6600 Series Chassis and Hardware Components Temperature Management

Viewing Fan Status

The switch also constantly monitors fan operation. If any of the three fans unexpectedly shuts down, the switch sends out a trap to the user and the FAN LED on the chassis front panel displays amber.

To check the current fan status, use the show fan command. For example:

-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running

In the example above, all three fans are operating normally.

Viewing Fan Status for Stacked Configurations

When entering the show fan command on the primary switch in a stacked configuration, you can either enter only the show fan syntax or you can specify a specific slot number. For more information, refer to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, fan status information for only the corresponding switch displays. For example:

-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running

In the example above, fan status displays only for the switch operating in slot 3.

Page 66 of the Alcatel-Lucent 6624 user manual — No Slot Number is Specified
Page 66 · click to enlarge
Page 66

Temperature Management OmniSwitch 6600 Series Chassis and Hardware Components

No Slot Number is Specified

If you do not enter a slot number, fan status information for all switches in the stack displays. For example:

-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running 2 1 Running 2 2 Running 2 3 Running 3 1 Running 3 2 Running 3 3 Running

The example above shows the fan status for a stack consisting of three switches. All fans for those switches—operating in slots 1, 2, and 3—are operating normally.

More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Page 67 of the Alcatel-Lucent 6624 user manual — Chassis Airflow
Page 67 · click to enlarge
Page 67

OmniSwitch 6600 Series Chassis and Hardware Components Temperature Management

Chassis Airflow

The fans pull air from the air intake vent located at the right-hand side of the chassis. The air is directed horizontally through the chassis and past the circuit board and uplink and stacking modules (if installed). Airflow is then exhausted through the fan vents at the left-hand side of the chassis. Refer to the illustra- tions below for more information.

1. Air Intake. The three chassis fans pull air from the main air intake vent located at the right-hand side of the chassis.

Uplink and Stacking Submodules

Right Side Air Intake Vent

2. Airflow. The air from the intake vent is directed through the chassis past the main circuit board and submodule daughtercards. This airflow provides required cooling for these chassis components.

Uplink and Stacking Submodules

3. Air Exhaust. The airflow is exhausted through the fan exhaust vents at the left-hand side of the chassis.

Left Side Fan Exhaust Vents

Show 4 more labels / short text on this page
Front of Chassis · Air Intake Vent · Front of Chassis · Fan Exhaust Vents
Page 68 of the Alcatel-Lucent 6624 user manual — Blank Cover Panels
Page 68 · click to enlarge
Page 68

Temperature Management OmniSwitch 6600 Series Chassis and Hardware Components

Blank Cover Panels

Blank cover panels are provided with your switch and are used to cover empty uplink and stacking module slots, as well as empty back up power supply bays (if applicable). These cover panels play an important role in chassis airflow and temperature management. They also protect the switch’s processor board and other sensitive internal switch components from physical damage by closing off a chassis that is not fully populated.

If your switch is not fully populated with submodules and a redundant power supply, and blank cover panels are not installed over empty slot locations, airflow is adversely affected.

When blank cover panels are missing, air does not take the direct route from the air intake vent, through the chassis, and then out through the fan exhaust vents. Instead, a portion of the airflow is allowed to be drawn in through the front and rear of the chassis. As a result, normal airflow is disrupted and an extra task is placed on the fans to cool the chassis.

Cover panels also provide protection for module processor boards and other sensitive internal switch components by closing off a chassis that is not fully populated.

Because they regulate airflow and help protect internal chassis components, blank cover panels should remain installed over empty module slots and power supply bays at all times.

Missing Cover Panels. Missing cover panels affect airflow by allowing air to be drawn in through the front submodule bays or rear redundant power supply bay. As a result, the direct route from the air intake vent to the fan exhaust vents is dis- rupted.

Air leakage due to missing redundant power supply panel

For optimal airflow and chassis component protec- tion, always install blank cover panels over empty slots and power supply bays.

Air leakage due to missing submodule cover panels

Effects of Missing Blank Panels on Chassis Airflow

Air Intake Vent

Page 69 of the Alcatel-Lucent 6624 user manual — 10/100 Ethernet Port – RJ-45 Pinout
Page 69 · click to enlarge
Page 69

OmniSwitch 6600 Series Chassis and Hardware Components Pinouts

Pinouts

10/100 Ethernet Port – RJ-45 Pinout

1 RX+

2 RX-

3 TX+

6 TX-

Copper Gigabit Ethernet Port – RJ-45 Pinout

1 BI_DB+

2 BI_DB-

3 BI_DA+

4 BI_DD+

5 BI_DD-

6 BI_DA-

7 BI_DC+

8 BI_DC-

RS232 Console Port – Female DB9 Connector Pinout

Pin Number Signals as DCE Console Port

2 RXD (from the switch)

3 TXD (to the switch)

Show 14 more labels / short text on this page
Pin Number Description · 4 not used · 5 not used · 7 not used · 8 not used · Pin Number Description · 1 Not used · 4 Not used · 5 Ground · 6 Not used · 7 Not used · 8 Not used · 9 Not used · Shell Chassis ground
Page 70 of the Alcatel-Lucent 6624 user manual — 2 NC
Page 70 · click to enlarge
Page 70

Pinouts OmniSwitch 6600 Series Chassis and Hardware Components

RJ-45 Console Port – Connector Pinout

Pin Number Signals as DCE Console Port

1 CTS (Clear To Send)

2 NC

3 RXD

4 GND

5 GND

6 TXD

7 NC

8 RTS (Request To Send)

Shell Chassis Ground

Page 71 of the Alcatel-Lucent 6624 user manual — Modifying the Serial Connection Settings
Page 71 · click to enlarge
Page 71

OmniSwitch 6600 Series Chassis and Hardware Components Console Port

Console Port

Serial Connection to the Console Port

The console port, located on the chassis front panel, provides a serial connection to the switch and is required when logging into the switch for the first time (refer to the OmniSwitch 6600 Series Getting Started Guide for more information). By default, this connector (a female DB-9 on OmniSwitch 6624 and 6648 switches and an RJ-45 port on OmniSwitch 6600-U24 switches) provides a DCE console connec- tion.

Serial Connection Default Settings

The factory default settings for the serial connection are as follows:

data bits (word size) 8

Modifying the Serial Connection Settings

If you wish to modify the default serial connection settings (i.e., baud rate, parity, data bits, and stop bits), refer to the following steps.

Note. You must be connected to the switch via the console port before attempting to change serial connec- tion settings. Otherwise, an error message will display. In addition, if you are changing console port settings for switches in a stack, console port settings must be identical on all switches. Before configuring the console port settings for a stack, make sure each switch is operating in either primary or secondary status (you may be required to disconnect switches within the stack before beginning).

1 Enter modify boot parameters at the CLI prompt. The boot prompt displays:

2 To change the baud rate, enter boot serialbaudrate, followed by the desired baud rate value. Options include 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 76800, and 115200. For example:

Boot > boot serialbaudrate 19200

3 To change the parity value, enter boot serialparity, followed by the desired parity value. Options include none (default), even, and odd. For example:

Boot > boot serialparity even

Show 4 more labels / short text on this page
baud rate 9600 · parity none · stop bits 1 · Boot >
Page 72 of the Alcatel-Lucent 6624 user manual — Console Port
Page 72 · click to enlarge
Page 72

Console Port OmniSwitch 6600 Series Chassis and Hardware Components

4 To change the data bits (i.e., word size) value, enter boot serialwordsize, followed by the number of data bits. Options include 7 and 8 (default). For example:

Boot > boot serialwordsize 7

5 To change the stop bits value, enter boot serialstopbits, followed by the number of stop bits. Options include 1 (default) and 2. For example:

Boot > boot serialstopbits 2

6 Verify your current changes by entering show at the boot prompt:

Boot > show Edit buffer contents: Serial (console) baud : 19200 Serial (console) parity : even Serial (console) stopbits : 2 Serial (console) wordsize : 7

(additional table output not shown)

7 You can save your changes to the boot.params file by entering commit file at the boot prompt:

Boot > commit file

8 You can also save your changes in real time to the switch’s running memory by entering commit system at the boot prompt:

Boot > commit system

  • Output to the terminal may become illegible due to incompatible serial connection settings between the switch and the terminal emulation software.
  • If you use the commit system command only, changes will not be saved to the switch’s boot.params file and will be lost if the switch is rebooted. To save changes to the boot.params file, refer to step 7.

9 Return to the CLI prompt by entering exit at the boot prompt.

Page 73 of the Alcatel-Lucent 6624 user manual — Hardware Information
Page 73 · click to enlarge
Page 73

OmniSwitch 6600 Series Chassis and Hardware Components Viewing Basic Chassis Information

Viewing Basic Chassis Information

This section covers the following basic chassis information and monitoring commands:

show hardware info show module show module long (and show ni) show chassis show cmm

  • For information on viewing primary and back up power supply status, refer to page 2-23 .
  • For information on viewing chassis temperature status, refer to page 2-42 .
  • For information on viewing chassis fan status, refer to page 2-45 .

Hardware Information

To view basic hardware information about the switch, enter the show hardware info command at the CLI prompt. This command displays the following information:

  • CPU type
  • Flash and RAM memory information
  • NVRAM battery status
  • Jumper settings
  • BootROM and Miniboot versions

For example:

-> show hardware info CPU Type : PowerPC 8245, Flash Manufacturer : SanDisk SDCFB-32 Flash size : 32505856 bytes (31 MB), RAM Manufacturer : DataRam, RAM size : 134217728 bytes (128 MB), NVRAM Battery OK : YES, Interrupt Boot Jumper : ON, Force UART Defaults Jumper : ON, Run Extended Memory Diags Jumper : ON, Spare Jumper : ON, BootROM Version : 5.1.2.125, Backup Miniboot Version : 5.1.2.125, Default Miniboot Version : 5.1.2.125,

Stacked Configurations. For remote sessions (e.g., Telnet and WebView) the show hardware info command displays information for only the primary switch. The command may also be used while connected directly to the primary or secondary switch via the console port. For detailed information on stacked OS6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Page 74 of the Alcatel-Lucent 6624 user manual — Slot and Component Information
Page 74 · click to enlarge
Page 74

Viewing Basic Chassis Information OmniSwitch 6600 Series Chassis and Hardware Components

Slot and Component Information

To view basic slot position and component information, enter the show module command at the CLI prompt. This command displays the following information:

  • Current slot position
  • Alcatel part number
  • Serial number
  • Hardware revision level
  • Manufacture date(s)
  • Model name, also referred to as chassis type

For example:

HW Mfg Slot Part-Number Serial # Rev Date Model Name + + +---+ +

CMM-1 902098-10 2313283p 210 FEB 05 2106€ OS6648

NI-1 902098-10 2313283p 210 FEB 05 2106€ OS6648

The Slot column lists both the main PCB (CMM) and 10/100 Ethernet bay (NI), along with the switch’s current slot position. CMM-1 and NI-1 indicates that the switch and its corresponding 10/100 Ethernet bay (a virtual Network Interface card) have been assigned to slot position 1.

For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.

Stacked Configurations. You can use the show module command to display information for all switches in a stack, or for a specified switch only. When the show module syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OS6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

-> show module

Page 75 of the Alcatel-Lucent 6624 user manual — Detailed Slot and Component Information
Page 75 · click to enlarge
Page 75

OmniSwitch 6600 Series Chassis and Hardware Components Viewing Basic Chassis Information

Detailed Slot and Component Information

To view more detailed slot and component information, including information on installed uplink and stacking modules, use the show module long command.

This command displays the following information:

  • Model name, also referred to as chassis type
  • Chassis description
  • Alcatel part number
  • Hardware revision level
  • Serial number
  • Manufacture date(s)
  • Current power and operational status
  • Base chassis MAC address (for more information on the base chassis MAC address, see page 2-59 )
  • ASIC and firmware information
  • Detailed information on all installed uplink and stacking modules
  • Information on all installed MiniGBICs

For example:

-> show module long CMM in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:00, ASIC - Physical:

(Screen output continued on next page.)

Page 76 of the Alcatel-Lucent 6624 user manual — Viewing Basic Chassis Information
Page 76 · click to enlarge
Page 76

Viewing Basic Chassis Information OmniSwitch 6600 Series Chassis and Hardware Components

Module in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:02, ASIC - Physical:

Daughter Board in port 1 Model Name: OS66MINIGBIC2 , Description: 2pt Giga Fiber, Part Number: 902084-10, Hardware Revision: 201, Serial Number: 2263006P, Manufacture Date: FEB 05 2106€, Firmware Version: , Admin Status: POWER ON, Operational Status: UP

GBIC 1 Model Name: IBM, Description: IBM, Part Number: IBM42P12SNY, Hardware Revision: AA10, Serial Number: 21P704213Z49IBM, Manufacture Date: 01040101, Firmware Version: , Admin Status: POWER ON, Operational Status: UP

Daughter Board in port 2 Model Name: OS66-STK-MOD , Description: 2pt Giga Stack, Part Number: 902086-10, Hardware Revision: 201, Serial Number: 2243041P, Manufacture Date: FEB 05 2106€, Firmware Version: , Admin Status: POWER ON, Operational Status: UP

For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.

Stacked Configurations. You can use the show module long command to display information for all switches in a stack, or for a specified switch only. When the show module long syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Page 77 of the Alcatel-Lucent 6624 user manual — Basic Primary Slot and Component Information
Page 77 · click to enlarge
Page 77

OmniSwitch 6600 Series Chassis and Hardware Components Viewing Basic Chassis Information

Basic Primary Slot and Component Information

To view basic slot and component information for the base chassis only (i.e., no installed uplink or stack- ing modules), enter the show cmm command at the CLI prompt. This command displays the following information:

  • Model name, also referred to as chassis type
  • Chassis description
  • Alcatel part number
  • Hardware revision level
  • Serial number
  • Manufacture date(s)
  • Current power and operational status
  • Base chassis MAC address
  • ASIC and firmware information

For example:

-> show cmm CMM in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:00, ASIC - Physical:

For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.

Stacked Configurations. You can use the show cmm command to display information for all switches in a stack, or for a specified switch only. When the show cmm syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Page 78 of the Alcatel-Lucent 6624 user manual — Basic Chassis Information
Page 78 · click to enlarge
Page 78

Viewing Basic Chassis Information OmniSwitch 6600 Series Chassis and Hardware Components

Basic Chassis Information

To view basic chassis information (i.e., no installed uplink or stacking modules), enter the show chassis command at the CLI prompt. This command displays the following information:

  • Model name, also referred to as chassis type
  • Chassis description
  • Alcatel part number
  • Hardware revision level
  • Serial number
  • Manufacture date(s)
  • Current power and operational status
  • Number of times the switch has been reset (i.e., rebooted) since it was last powered up

For example:

Chassis 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Admin Status: POWER ON, Operational Status: UP, Number Of Resets: 271

For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.

Stacked Configurations. You can use the show chassis command to display information for all switches in a stack, or for a specified switch only. When the show chassis syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

-> show chassis

Page 79 of the Alcatel-Lucent 6624 user manual — OmniSwitch 6600 Series MAC Range Specifications
Page 79 · click to enlarge
Page 79

OmniSwitch 6600 Series Chassis and Hardware Components Managing MAC Addresses on the Switch

Managing MAC Addresses on the Switch

Your OmniSwitch 6600 series switch is shipped with thirty-two (32) factory-installed MAC addresses. These MAC addresses, which are stored on an EEPROM card in the chassis, are used by the switch as unique identifiers for the following functions:

  • Base chassis MAC address
  • 802.1X authentication
  • VLAN router ports

Similar to IP addresses, MAC addresses are assigned by the Internet Assigned Numbers Authority (IANA) and distributed to users in sequential blocks. A sequential block of MAC addresses is referred to as a MAC address range.

The switch’s EEPROM contains two factory-installed MAC address ranges:

MAC Range 1 Reserved for the first two MAC addresses in the factory installed range of 32 MAC addresses. The first—or start—MAC address in this range is always allocated as the base chassis MAC address. The second MAC address is allocated for 802.1X authentication.

MAC Range 3 Contains the switch’s remaining unused MAC addresses (i.e., MAC addresses 3 through 32).

MAC Range Guidelines

  • You cannot edit or delete MAC range 1 or MAC range 3 at any time.
  • The factory-installed 32 MAC addresses are sufficient for most network configurations. However, if you require additional MAC addresses for your network, you may purchase additional MAC addresses from Alcatel. Contact your Alcatel representative for more information.

OmniSwitch 6600 Series MAC Range Specifications

Number of Factory-installed MAC Ranges 2 (MAC Range 1; MAC Range 3)

Number of MAC Addresses in Default Range 1 2

Number of MAC Addresses in Default Range 3 30

Maximum MAC Ranges on Switch 2 (MAC Range 1; MAC Range 3)

Base chassis MAC address Unique to each switch. The base chassis MAC address is always the first MAC address listed in the switch’s default MAC range 1.

Supported MAC Router Mode Single

Page 80 of the Alcatel-Lucent 6624 user manual — Base Chassis MAC Address in Stacked Configurations
Page 80 · click to enlarge
Page 80

Managing MAC Addresses on the Switch OmniSwitch 6600 Series Chassis and Hardware Components

Base Chassis MAC Address as Unique Identifier

The switch chassis requires a unique identifier in order to be recognized by other devices in the network. The base chassis MAC address, which is automatically allocated by the switch, serves as this identifier. The base chassis MAC address is always the start MAC address listed in the switch’s default MAC range 1.

Viewing the Base Chassis MAC Address

To display the switch’s base chassis MAC address, use the show mac-range command to display the default MAC range 1. Be sure to specify the MAC range number ( 1 ), as shown below:

-> show mac-range 1

The following information displays:

Mac Local/ Range Row Status Global Start Mac Addr End Mac Addr + 01 ACTIVE GLOBAL 00:d0:95:6a:79:6e 00:d0:95:6a:79:8d

Because MAC address 00:d0:95:6a:79:6e is the first address in default MAC range 1, it is automatically allocated as the base chassis MAC address and, therefore, serves as a unique identifier for the switch as a whole.

Determining Current MAC Address Allocation on the Switch

To quickly view all allocated MAC addresses, use the show mac-range alloc command. For example:

Mac Local/ Range Row Status Global Start Mac Addr End Mac Addr + 01 ACTIVE GLOBAL 00:d0:95:12:db:60 00:d0:95:12:db:61 03 ACTIVE GLOBAL 00:d0:95:12:db:62 00:d0:95:12:db:7d

Base Chassis MAC Address in Stacked Configurations

In stacked configurations of two or more OmniSwitch 6600 series switches, the base MAC address for the stack (also referred to as the virtual chassis) is always provided by the primary switch.

If a failover occurs and another switch assumes the primary role, the stack’s base MAC address changes to the address provided by the new primary switch.

For detailed information on stacked configurations, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

-> show mac-range

Page 81 of the Alcatel-Lucent 6624 user manual — In This Chapter
Page 81 · click to enlarge
Page 81

3 Managing OmniSwitch Managing OmniSwitch

6600 Series Stacks

In addition to working as individual stand-alone switches, OmniSwitch 6600 series switches can also be linked together to work as a single virtual switch known as a stack. With stacks you can easily expand your switching capacity simply by adding additional switches. In addition, stacks provide enhanced resil- iency and redundancy features.

In This Chapter

The chapter describes basic steps to configure up to eight (8) OmniSwitch 6600 series switches into a stack. In addition, procedures using Command Line Interface (CLI) commands to monitor the status of stacks are also provided.

Procedures described in this chapter include:

  • Setting up a stacked configuration on page 3-8 .
  • Managing switches on a stack on page 3-16 .
  • Monitoring stacks with CLI commands on page 3-19 .
Page 82 of the Alcatel-Lucent 6624 user manual — Specifications and Default Values
Page 82 · click to enlarge
Page 82

Specifications and Default Values Managing OmniSwitch 6600 Series Stacks

Specifications and Default Values

The table below lists specifications for OmniSwitch 6600 series stacks.

Minimum number of switches in a stack. 2

Maximum number of switches in a stack. 8

Stacking module kits (which include stacking module and cables) model number (OmniSwitch 6624, 6600-U24, and 6648 only)

OS66-STK-KIT (30 cm cable) and OS66-RST-KIT (1 meter cable)

Stacking port locations on an OmniSwitch 6624 and 6600-U24

Ports 25 and 26

Stacking port locations on an OmniSwitch 6648 Ports 51 and 52

The table below lists default values for OmniSwitch 6600 series stacks.

Parameter Description Configuration Steps Default Value

Switch slot number See “Assigning Slot Numbers” on page 3-8.

Page 83 of the Alcatel-Lucent 6624 user manual — EXPANSION/STACKING
Page 83 · click to enlarge
Page 83

Managing OmniSwitch 6600 Series Stacks Stack Overview

Stack Overview

By default, OmniSwitch 6600 series switches operate in stand-alone mode. You can also configure two to eight OmniSwitch 6600 series switches (in any combination of OmniSwitch 6624, 6600-U24, and 6648 switches) into one large virtual chassis known as a stack. With stacks, you can easily expand your switch- ing capacity simply by adding additional switches. For example, you can start with a stack composed of two switches and add switches (up to eight) as network demands increase.

Note on Terminology. In the user guides provided with your OmniSwitch 6600 series switch, the terms switch, slot and NI (Network Interface) refer to individual OmniSwitch 6600 series units in stand-alone mode or within a stack. The term CMM (Chassis Management Module) refers to OmniSwitch 6600 series units operating in a stack in a primary or secondary CMM role. (OmniSwitch 6600 series switches operat- ing in an idle CMM role would normally be referred to as a switch, slot, or, NI.)

Stacks also provide enhanced resiliency and redundancy features. If a switch in a stack goes down or is offline, the stack will continue to operate without user intervention. In addition, when a switch auto- synchronizes at boot-up or if you manually synchronize the switches (see “Synchronizing Switches in a Stack” on page 3-17 for more information) switch operating software and configuration parameters are backed up on all switches in the stack. Therefore if software is corrupted or damaged the original operat- ing software and parameters can be recovered.

Switches are connected to each other in a stack with stacking modules. (See Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” in this manual for more information.) These stacking modules provide high-speed, dual-redundant links between switches in a stack. The figure below shows an exam- ple of a stack composed of four switches. Every switch in a stack is connected to other switches in a stack in a dual-redundant “daisy-chain” manner.

This stack is composed of four OmniSwitch 6648 switches. All switches in this stack are connected together in a dual-redundant “daisy-chain” manner.

EXPANSION/STACKING

EXPANSION 49 50 51 52

LINK/ACT LINK/ACT

EXPANSION/STACKING

EXPANSION 49 50 51 52

LINK/ACT LINK/ACT

EXPANSION/STACKING

EXPANSION 49 50 51 52

LINK/ACT LINK/ACT

CONSOLE

OK1

PS1

PRI

TEMP

FAN

SEL

EXPANSION 49 50 51 52

EXPANSION/STACKING

OK2

PS2

SEC

LINK/ACT LINK/ACT

CONSOLE

OK1

PS1

PRI

SEC

TEMP

FAN

SEL

OK2

PS2

CONSOLE

OK1

PS1

PS2

PRI

SEC

TEMP

FAN

SEL

OK2

CONSOLE

TEMP

SEL

OK1

PS1

PS2

PRI

SEC

FAN

OK2

A Stack Composed of Four OmniSwitch 6648 Switches

Show 4 more labels / short text on this page
TM OmniSwitch 6624 · TM OmniSwitch 6624 · TM OmniSwitch 6624 · TM OmniSwitch 6624
Page 84 of the Alcatel-Lucent 6624 user manual — Slot Numbers within a Stack
Page 84 · click to enlarge
Page 84

Stack Overview Managing OmniSwitch 6600 Series Stacks

Stacking Resiliency and Redundancy

The figure on page 3-3 shows a sample way to connect switches in a four-switch stack to ensure dual- redundant connections. Except for the bottommost switch in the stack, Port 52 is connected to Port 51 on the switch below it with a 30 centimeter stacking cable. On the bottommost switch Port 52 is connected to Port 51 on the topmost switch in the stack with a 1 meter redundant stacking cable. If a stacking connec- tion goes down data can still flow between all the switches in the stack. In addition, if a switch goes down traffic can still flow between the switches that are still operating.

Slot Numbers within a Stack

By default, the slot number for OmniSwitch 6600 series switches is 8. In a stand-alone configuration you would enter 8 when a Command Line Interface (CLI) command requires a slot number. For example, to create VLAN 10 on port 1 on an OmniSwitch 6600 series with the default slot number you would enter

vlan 10 port default 8/1

In a stack, each switch must have a unique slot number, which is configured by the user. (See “Managing Switches in a Stack” on page 3-16 for more information.) This slot number can be any whole number between 1 and 8.

For example, if you have assigned slot number 2 to a switch you would enter

vlan 10 port default 2/1

The slot number for each switch is stored in the root /flash directory in the boot.slot.cfg file. This file must exist on every switch in a stack or the stack will not be able to operate correctly. If you accidently delete this file the switch will revert to the default slot number of 8 and will operate in standby mode. To restore the slot number and rejoin the switch to the stack you must physically change the slot by following the steps described in Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” and reboot the switch.

Page 85 of the Alcatel-Lucent 6624 user manual — CMM Role Redundancy
Page 85 · click to enlarge
Page 85

Managing OmniSwitch 6600 Series Stacks Stack Overview

CMM Roles in a Stack

When OmniSwitch 6600 series switches operate in a stack, one switch in the stack will always have a primary CMM (Chassis Management Module) software role within the stack. This switch will be responsi- ble for functions such as software and configuration management, web-based management (i.e., WebView), SNMP management, switch diagnostics, and software rollback.

Another switch will have a secondary CMM role. This switch acts as a backup, which is always ready to assume the primary CMM role in the stack if the switch with the primary CMM role fails or goes offline. Any additional switches will have an idle CMM role in the stack. These switches operate similarly to Network Interfaces (NIs) in a chassis-based switch.

By default, the primary—or management—role will be given to the switch with the lowest chassis MAC address. All other switches in the stack will be in non-operational status until slot numbers are assigned by the user and the stack is manually rebooted.

Once unique slot numbers are assigned to switches in a stack, the switch with the lowest slot number will assume the primary CMM role while the switch with the next lowest slot number will assume the second- ary CMM role when the stack firsts boots up. Any other switches in the stack will assume an idle CMM role. For example, in a stack with switches numbered 2, 5, 7, and 8, Switch 2 will assume the primary role, Switch 5 will assume the secondary role while switches 7 and 8 will assume idle roles.

In a stack, if the switch with the primary CMM role fails or goes offline for any reason, all the other switches in the stack are instantly notified. The switch with the secondary CMM role automatically assumes the primary role. In a stack consisting of two switches, the switch that had the primary role will assume the secondary role if it comes back online. In a stack consisting of three or more switches the switch with the next lowest slot number will be assigned the secondary CMM role while the switch that was originally primary will have an idle CMM role if it comes back online.

Note. If a primary switch goes down in a stack consisting of three or more switches and then comes back online again, it will assume an idle CMM role, not the secondary role. If you want a switch with an idle role and the lowest slot number in a stack to regain the primary CMM role you must reboot all the switches in the stack. (See “Resetting All Switches in a Stack” on page 3-18 for more information.)

CMM Role Redundancy

CMM role redundancy is one of the stack’s most important failover features. The switch with the primary CMM role manages the current switch operations, the switch with the secondary CMM role provides backup (also referred to as “failover”), and any remaining switches in the stack are in an idle CMM role. For CMM redundancy, the software on all the switches in the stack must be synchronized. (Refer to “Synchronizing Switches in a Stack” on page 3-17 for more information.)

The figure on the following page illustrates the CMM failover sequence:

1 Switch 1 is operating in the primary CMM mode. Switch 2 is operating in the secondary mode—i.e., it is functioning with the standby CMM role and is ready to take over chassis management functions in the event of a failure of the switch with the primary CMM role.

2 Switch 1 fails or is taken offline (e.g., the switch is physically removed from the stack).

3 Switch 2 automatically assumes the primary CMM role.

4 Switch 3 automatically assumes the secondary CMM role.

5 Switch 4 remains in the Idle CMM role.

Page 86 of the Alcatel-Lucent 6624 user manual — CLI Commands Supported on Both the Primary and Secondary Role Switches
Page 86 · click to enlarge
Page 86

Stack Overview Managing OmniSwitch 6600 Series Stacks

Please note that in this example Switch 1 will assume an idle CMM role if it comes back on line.

Switch 1 fails or is taken offline

!

*If Switch 1 comes back on line it will be in idle mode, not primary or secondary.

Redundant CMM Role Failover

CLI Commands Supported on Both the Primary and Secondary Role Switches

Although most CLI commands are executed when logged into the switch with primary CMM role, there is a group of commands that is supported when logged in to either the switch with primary role or the switch with the secondary CMM role. For a list of these commands, refer to the tables below. The tables are grouped by chapter according to the OmniSwitch CLI Reference Guide.

debug chassis auto-reboot show running-directory show reload

show microcode show stack topology show restore redundancy status

Chassis Management and Monitoring Commands

show system show hardware info show chassis

show module show module long show module status

show cmm show ni

cd pwd mkdir rmdir ls dir rename rm

delete cp mv move chmod attrib fsck newfs

ed vi view tty show tty rz more install

Show 23 more labels / short text on this page
Switch 1 (Primary) · Switch 1 (Offline)* · Switch 2 (Secondary) · Switch 2 · (Primary) · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · OmniSwitch 6648 · Switch 3 · Switch 3 (Secondary) · OmniSwitch 6648 · (Idle) · OmniSwitch 6648 · Switch 4 · Switch 4 · (Idle) · (Idle) · CMM Commands · reload takeover install · File Management Commands
Page 87 of the Alcatel-Lucent 6624 user manual — CLI Commands Supported on Both the Primary and Secondary Role Switches
Page 87 · click to enlarge
Page 87

Managing OmniSwitch 6600 Series Stacks Stack Overview

Switch Logging and Monitoring Commands

swlog swlog appid level swlog output show log swlog show swlog

debug ktrace debug ktrace appid level debug ktrace show debug systrace debug systrace appid level

debug systrace show debug systrace show log debug memory monitor debug memory monitor show log

Memory Monitoring Commands · show log pmd

Page 88 of the Alcatel-Lucent 6624 user manual — Assigning Slot Numbers
Page 88 · click to enlarge
Page 88

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Series Stacks

Setting Up a Stacked Configuration

In order to set up a new stacked OmniSwitch 6600 series configuration, you must complete the following steps, in the order they are listed:

1 Individually assign slot numbers to all switches

2 Attach all required stacking cables

3 Boot the newly-configured stack

For OmniSwitch 6600 series switches, the term “slot” refers to the priority status of the switch within the stacked configuration. Slot numbers may range from 1 to 8. For detailed instructions on setting up a stack, refer to the sections below.

Assigning Slot Numbers

Before assigning slot numbers to switches in a stacked configuration, note the following important guidelines:

  • The slot number is displayed by the slot indicator LED located on the left side of the chassis front panel (refer to “Status LEDs” on page 2-11 for more information).
  • Slot numbers do not need to be sequential. However, each switch in a stack must have a unique slot number . If duplicate slot numbers are encountered, an error will occur and the stack will be disabled.
  • The top switch in the stack does not have to be designated as slot 1.
  • By default, the primary —or management—role will be given to the switch with the lowest chassis MAC address. All other switches in the stack will be in non-operational status until slot numbers are assigned by the user and the stack is manually rebooted.
  • After manually assigning the slot assignments for all switches and rebooting the stack, the primary role will be given to the switch with the lowest slot number. The secondary role will be given to the switch with the next-lowest number. All additional switches with higher numbers will be given idle status.
  • Changing the slot number of a chassis does not immediately change its management role (i.e., primary, secondary, or idle). You must reboot all the switches in the stack before these changes will take effect .
  • Refer to the illustration on page 3-10 for one of many valid slot numbering possibilities.

To assign a new slot number to one or more switches in a stack, follow the steps below:

1 To change the slot number, gently insert a pointed item, such as the open, pointed end of a paper clip, into the small hole (labeled SEL) below the slot number LED on the switch’s front panel. The LED display will begin to flash. You can manually change the slot number as long as the LED continues to flash.

Page 89 of the Alcatel-Lucent 6624 user manual — OK1
Page 89 · click to enlarge
Page 89

Managing OmniSwitch 6600 Series Stacks Setting Up a Stacked Configuration

2 Change the slot number by gently pressing the pointed item into the SEL hole again. Each time the SEL button is pressed, the LED display increases or decreases in increments of one.

PRI

TEM

FAN SEL

28 30 32 34

PS1

10 12 14 16

OK1

SEC

PS2

OK2

CONSOLE

TEMP

SEL

PRI

PS1

FAN

OK1

SEC

OK2

PS2

3 Continue pressing the SEL button until you reach the number that is one increment higher that the desired slot number, then hold in the SEL button until the LED decreases one increment (to your desired number) and stops flashing.

4 Power off the switch.

5 Continue steps 1 through 4 for any additional switches that are being assigned new slot numbers.

6 Continue to “Connecting Cables to Stacking Ports” on page 3-11.

TM OmniSwitch 6624 · SEL Button Location

Page 90 of the Alcatel-Lucent 6624 user manual — CONSOLE
Page 90 · click to enlarge
Page 90

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Series Stacks

Slot Numbering Example

Valid Slot Assignments. The illustration at left (showing a stacked configuration with four switches) shows one of many valid slot numbering possibilities.

CONSOLE

  • Although the slot numbers are not sequential (4, 5, 6, and 3), all switches in the stack have a unique slot number .

PRI

TEMP

SEL

OK1

PS1

FAN

OK2

PS2

SEC

  • The top switch in the stack does not have to be designated as slot 1; for this example, the top switch has been designated slot number 4.

CONSOLE

PRI

TEMP

SEL

OK1

PS1

FAN

OK2

PS2

SEC

  • Because it has the lowest userassigned slot number, switch number 3 will be given the stack’s primary management role in this example. Switch number 4 will be given the secondary role. Switches 5 and 6 will be given idle status.

CONSOLE

PRI

TEMP

SEL

OK1

PS1

FAN

PS2

SEC

OK2

CONSOLE

TEMP

SEL

OK1

PS1

PRI

FAN

PS2

SEC

OK2

Stack of Four Switches with Unique Slot Numbers

Show 5 more labels / short text on this page
32 34 36 · TM OmniSwitch 6624 · TM OmniSwitch 6624 · TM OmniSwitch 6624 · TM OmniSwitch 6624
Page 91 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 91 · click to enlarge
Page 91

Managing OmniSwitch 6600 Series Stacks Setting Up a Stacked Configuration

Connecting Cables to Stacking Ports

On OmniSwitch 6624, 6600-U24, and 6648 switches only, note the following important guidelines before connecting stacking cables to stacking modules:

  • Before attempting to connect OS6624, OS6600-U24, and OS6648 switches in a stacked configuration, be sure that stacking modules are installed in the EXPANSION/STACKING slots of all switches. The stacking module provides two dedicated High Speed Serial Data Connectors (HSSDCs) at ports 27 and 28 (OS6624 and OS6600-U24) or 51 and 52 (OS6648). For detailed information on installing stacking modules, refer to “Installing Uplink and Stacking Modules” on page 2-29 .
  • Stacking modules can only be installed in the far-right module slot. This slot is labeled EXPANSION/ STACKING and contains port positions 27 and 28 (OS6624 and OS6600-U24) or 51 and 52 (OS6648).
  • Do not attempt to install the stacking module at the EXPANSION slot at port positions 25 and 26 (OS6624 and OS6600-U24) or 49 and 50 (OS6648).

On all OmniSwitch 6600 series switches, note the following important guidelines before connecting stack- ing cables to stacking modules:

  • If you have not already individually assigned slot numbers and powered off each switch, do not connect stacking cables to the stacking ports. Instead, refer to “Assigning Slot Numbers” on page 3-8 and follow the instructions for assigning slot numbers to each switch.
  • Port numbers are clearly marked on the chassis front panel.
  • For information on setting up stack redundancy, refer to “Redundant Stack Connection” on page 3-13 .

To connect stacking cables to stacking modules and link your OmniSwitch 6600 series switch into a virtual chassis, follow the steps below:

1 Starting from the top of the stack, attach one end of a 30 cm stacking cable to a High Speed Serial Data Connector (HSSDC) port, as shown.

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

Attaching the Stacking Cable to a Stacking Port

Page 92 of the Alcatel-Lucent 6624 user manual — LINK/ACT LINK/ACT
Page 92 · click to enlarge
Page 92

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Series Stacks

2 Next, attach the other end of the cable to a HSSDC connector on the switch immediately below. Repeat this procedure until all switches in the stack are connected (see illustrations a, b, and c below).

EXPANSION/STACKING

EXPANSION/STACKING

EXPANSION/STACKING

5 1 5 2

5 1 5 2

5 1 5 2

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

EXPANSION/STACKING

EXPANSION/STACKING

EXPANSION/STACKING

5 1 5 2

5 1 5 2

5 1 5 2

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

EXPANSION/STACKING

EXPANSION/STACKING

EXPANSION/STACKING

5 1 5 2

5 1 5 2

5 1 5 2

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

EXPANSION/STACKING

EXPANSION/STACKING

EXPANSION/STACKING

5 1 5 2

5 1 5 2

5 1 5 2

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

LINK/ACT LINK/ACT

a b c

Connecting the Switches in the Stack

3 To provide added resiliency and redundancy, it is strongly recommended that you install the optional one-meter stacking cable to connect the top switch in the stack to the bottom switch in the stack. Use the unused HSSDC stacking connectors located at ports 27 and 28 (OS6624 and OS6600-U24) or 51 and 52 (OS6648) of each switch, as shown. For more information on stack redundancy and the one-meter stack- ing cable, refer to “Redundant Stack Connection” on page 3-13.

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

EXPANSION/STACKING

5 1 5 2

LINK/ACT LINK/ACT

Recommended Redundant Connection Between Switches

4 Now that all switches in the stack are connected, continue to “Booting the Stack” on page 3-14.

Page 93 of the Alcatel-Lucent 6624 user manual — Redundant Stack Connection
Page 93 · click to enlarge
Page 93

Managing OmniSwitch 6600 Series Stacks Setting Up a Stacked Configuration

Redundant Stack Connection

The figure below shows how the redundant connection (provided by the OS66STK-CBL1M cable) between the top and bottom switches in the stack ensures that data will continue to flow throughout the stack, even in the unlikely event of a connection failure between two switches.

No Connection Failure In this example, there is a VLAN with an ingress port on switch 1 and an egress port on switch 2.

Data enters switch 1 via a 10/100 Ethernet port, then is passed to switch 2 over the OS66STK-CBL30 stacking cable connection, then exits switch 2 via a 10/100 Ether- net port.

Connection Failure Between Switches 1 and 2 Here, the stacking connection between switches 1 and 2 has gone down unexpectedly. Data can no longer travel directly between switches 1 and 2.

However, because there is a redundant connection (the OS66STK-CBL1M cable between switches 1 and 4), data is passed to switch 4, then quickly traverses switch 3 and exits switch 2 to its destination.

Stacking Cable Redundancy Example

Show 8 more labels / short text on this page
Switch 1 · Switch 2 · Switch 3 · Switch 4 · Switch 1 · Switch 2 · Switch 3 · Switch 4
Page 94 of the Alcatel-Lucent 6624 user manual — SEC LED
Page 94 · click to enlarge
Page 94

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Series Stacks

Booting the Stack

In order for the switches in the stack to operate using their newly-assigned slot numbers, all switches in the stack must be manually booted.

Important. Whenever booting a stacked configuration, note that the primary switch will automatically distribute its system and configuration software to all switches in the stack whenever the virtual chassis boots. During this automatic software synchronization, system and configuration software on the second- ary and idle switches is overwritten. Because the primary switch’s “last known good” software is propa- gated to all switches, the synchronization process helps ensure effective redundancy across the stack.

To manually boot the stack, follow the steps below.

1 Power on all switches by moving the on/off switch for each switch to the on ( | ) position.

2 If back up power supplies are installed in one or more switches in the stack, power on all back up power supplies at this time.

Verifying Slot Number Assignments

After the stack is completely booted, all switches in the stack operate using the user-assigned slot numbers. To verify the slot numbers for each switch, refer to the slot indicator LED on the front panel of each switch. For more information, refer to “Status LEDs” on page 2-11.

Verifying Primary and Secondary Status for the Stack

Primary, Secondary and Idle switch status is indicated by the PRI and SEC LEDs. The PRI and SEC LEDs on the switch’s front panel are the most accurate and reliable method for determining the current role of a switch within a stacked configuration.

PRI LED

Now that the stack has been configured and booted, the primary—or management—role should be assigned to the switch with the lowest assigned slot number. In other words, if you assigned a switch in the stack as slot 1, this switch should have the primary role.

To verify this, check the PRI LED on the front panel of the switch with the lowest assigned slot number. The PRI LED should be illuminated solid green.

SEC LED

The secondary role is given to the switch with the next-lowest number.

To verify this, check the SEC LED on the front panel of the switch with the next-lowest assigned slot number. The SEC LED should be illuminated solid green.

Page 95 of the Alcatel-Lucent 6624 user manual — Idle Status
Page 95 · click to enlarge
Page 95

Managing OmniSwitch 6600 Series Stacks Setting Up a Stacked Configuration

Idle Status

All additional switches with higher numbers will be given idle status. The PRI and SEC LEDs for these switches will be off.

Additional LED Descriptions. For complete descriptions of OmniSwitch 6600 series LED states, see “Status LEDs” on page 2-11.

Page 96 of the Alcatel-Lucent 6624 user manual — Reloading the Switch with the Secondary CMM Role
Page 96 · click to enlarge
Page 96

Managing Switches in a Stack Managing OmniSwitch 6600 Series Stacks

Managing Switches in a Stack

Most Command Line Interface (CLI) commands can be used to configure OmniSwitch 6600 series switches operating in either stand-alone or stack configuration. This section describes how to use CLI commands to manage switches operating in a stack.

These functions include reloading switches with a primary or secondary CMM role (see “Reloading a Switch with a Primary or Secondary CMM Role” on page 3-16), synchronizing flash memory in the stack (see “Synchronizing Switches in a Stack” on page 3-17), managing the Chassis Management Module (CMM) roles in a stack (“Changing the Secondary CMM Role to Primary” on page 3-18), and resetting all switches in a stack (“Resetting All Switches in a Stack” on page 3-18).

Reloading a Switch with a Primary or Secondary CMM Role

You can reload a switch with either the primary or secondary CMM role using the CLI’s reload command. For information on using this command, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6624/6648 Switch Management Guide. A CMM reload is essentially a soft boot of the switch. Note that you can reload only one switch at a time with this command.

Reloading the Switch with the Primary CMM Role

If the switch with the primary CMM role is reloaded, the switch with the secondary CMM role automati- cally takes over primary management functions. In other words, the switch with the secondary CMM role assumes the primary CMM role as soon as the reload is initiated.

If there are only two switches in the stack then the reloaded switch will assume the secondary—or redun- dant—CMM role. If there are three or more switches in the stack then the reloaded switch will assume an idle role when the reload sequence is complete. The idle switch with the lowest slot number will assume the secondary CMM role.

Reloading the Switch with the Secondary CMM Role

If the switch with secondary CMM role is reloaded, then the idle switch with the lowest slot number will become secondary. The reloaded switch (i.e., the former secondary) will assume an idle role. The switch with the primary CMM role continues all operations without interruption.

Page 97 of the Alcatel-Lucent 6624 user manual — Restoring Switch Redundancy
Page 97 · click to enlarge
Page 97

Managing OmniSwitch 6600 Series Stacks Managing Switches in a Stack

Synchronizing Switches in a Stack

“CMM” synchronization refers to the process of copying all files in the /flash/working and /flash/ certified directories of the switch with the primary Chassis Management Module (CMM) role to the /flash/working and /flash/certified directories of all the other switches in the stack. (This includes the switch with the secondary CMM role and all the switches with an idle CMM role.)

This synchronization process ensures that these directories match exactly for all switches in the stack. Synchronization prevents any switch in the stack from assuming the primary role with incorrect or outdated software or configuration files.

To synchronize the switches in the stack, enter the following command at the CLI prompt:

-> copy working certified flash-syncro

For more information on CMM synchronization and managing the /flash/working and /flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6624/6648 Switch Management Guide.

Restoring Switch Redundancy

Once the copy flash-synchro command has been issued, the switches in the stack will have the correct software, but will not have loaded it into the running directory until the stack is rebooted. To reboot the stack for synchronization, use the restore redundancy command, as shown:

This command will cause each element in the stack to reload.

It may not be expedient to reboot a stack immediately after synchronizing the elements in the stack. It is possible to cause a synchronization reboot at a future time by setting time parameters in conjuction with the restore redundancy command, using the in or at keywords.

To schedule a resynchronization of a stack in 3 hours and 3 minutes, you would enter:

-> restore redundancy in 3:03

To schedule a resynchronization of a stack for June 30 at 8:00pm, you would enter:

-> restore redundancy at 20:00 june 30

To cancel a scheduled resynchronization enter:

-> restore redundancy cancel

-> restore redundancy

Page 98 of the Alcatel-Lucent 6624 user manual — Module Behavior During Takeover
Page 98 · click to enlarge
Page 98

Managing Switches in a Stack Managing OmniSwitch 6600 Series Stacks

Changing the Secondary CMM Role to Primary

To change a switch with a secondary role to primary use the takeover command. For example, while logged into either the primary or secondary switch enter:

at the CLI prompt. In a stack consisting of two switches the primary switch will become secondary. In a stack consisting of three or more switches the secondary switch will become primary, the idle switch with lowest slot number will become secondary, and the switch that was primary will become idle.

You can determine the current CMM role of a switch by examining the PRI and SEC LEDs on the switch’s front panel. Refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” for more information. You can also use the show running-directory command to display whether the switch into which you are currently logged is primary or secondary. For example:

-> show running-directory Running CMM : PRIMARY, Running configuration : CERTIFIED, Certify/Restore Status : CERTIFY NEEDED, Synchronization Status : SYNCHRONIZED, Stacks Reload on Takeover: PRIMARY ONLY

In this example, the user is currently logged in to the switch with the primary CMM role.

Module Behavior During Takeover

If there are no unsaved configuration changes and the flash directories on both the primary and secondary management modules have been synchronized via the copy flash-synchro command, no modules will be reloaded if a management module takeover occurs. As a result, data flow is not interrupted on the modules during the takeover.

If a configuration change is made to one or more modules (e.g., a VLAN is configured on several differ- ent interfaces), and the changes are not saved via the write memory command, the corresponding modules will automatically reload if a management module takeover occurs. Data flow on the affected modules will be interrupted until the reload is complete. Note that the modules will reload whether or not the flash synchronization status shows SYNCHRONIZED. This is because the unsaved changes have occurred in the running configuration (i.e., RAM), and have not been written to the flash directory’s configuration file. In this case, a list of only the affected modules displays in the table output (e.g., 1 6 9 12).

If the flash directories on the primary and secondary management modules are not synchronized (e.g., a copy flash-synchro command has not been issued recently), all modules will be reloaded automatically if a management module takeover occurs. Data flow will be interrupted on all modules until the reload is complete.

-> takeover

Page 99 of the Alcatel-Lucent 6624 user manual — Resetting All Switches in a Stack
Page 99 · click to enlarge
Page 99

Managing OmniSwitch 6600 Series Stacks Managing Switches in a Stack

Resetting All Switches in a Stack

To reset all switches in a stack you use the reload all command by entering

at the CLI prompt. This command can be helpful in restoring the original CMM roles in a stack (see “CMM Role Redundancy” on page 3-5).

-> reload all

Page 100 of the Alcatel-Lucent 6624 user manual — Monitoring Stack Topology
Page 100 · click to enlarge
Page 100

Monitoring Stacks Managing OmniSwitch 6600 Series Stacks

Monitoring Stacks

As shown in the figure below, OmniSwitch 6600 series stacks can be managed and monitored with Command Line Interface (CLI) commands, WebView, SNMP, and OmniVista. See “Monitoring Stack Topology” on page 3-19 for information on monitoring stack configurations and see Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” for information on monitoring and moni- toring stack temperature and chassis configurations.

Stacks can be managed and monitored through the console port with CLI commands.

Stacks can be managed and monitored through Ethernet ports with CLI commands, WebView, SNMP, and OmniVista.

Managing and Monitoring OmniSwitch 6600 Series Stacks

Monitoring Stack Topology

To monitor the topology of individual switches within a stack or all switches within a stack use the show stack topology command by entering

-> show stack topology

at the CLI prompt. A screen similar to the following will be displayed:

Link A Link A Link A Link B Link B Link B NI Role State RemoteNI RemoteLink State RemoteNI RemoteLink ---+ 1 PRIMARY ACTIVE 2 27 ACTIVE 2 28 2 SECONDARY ACTIVE 1 51 ACTIVE 1 52

The Role field displays the Chassis Management Module (CMM) role of the switch. The “RemoteNI and “RemoteLink” fields display how the stacking ports are connected to each other within this stack. “Link A” refers to the left-hand stacking port (Port 27 on OS6624 and OS6600-U24 switches and Port 51 on OS6648 switches) and “Link B” refers to the right-hand stacking port (Port 28 on OS6624 and OS6600- U24 switches and Port 52 on OS6648 switches).

Show 4 more labels / short text on this page
OmniSwitch 6624 Stack · OmniSwitch 6624 · OmniSwitch 6624 · OmniSwitch 6624
Page 101 of the Alcatel-Lucent 6624 user manual — Monitoring Stacks
Page 101 · click to enlarge
Page 101

Managing OmniSwitch 6600 Series Stacks Monitoring Stacks

In the example on the previous page there are two switches in this stack. Switch 1, which is an OS6648, has the primary CMM role and Switch 2, which is an OS6624, has the secondary CMM role. Switch 1’s left-hand stacking port (Port 51) is connected to Switch 2’s left-hand stacking port (Port 27). Switch 1’s right-hand stacking port (Port 52) is connected to Switch 2’s right-hand stacking port (Port 28). The Link A State and Link B State fields indicate that the links between the switches are currently active and running.

As an option you can display the topology of a single switch in a stack by entering show stack topology followed by the slot number of the switch. For example, to display the topology of switch (slot) you would enter

-> show stack topology 2

at the prompt. A screen similar to the following would be display:

Link A Link A Link A Link B Link B Link B NI Role State RemoteNI RemoteLink State RemoteNI RemoteLink ---+ 2 SECONDARY ACTIVE 1 51 ACTIVE 1 52

Page 102 of the Alcatel-Lucent 6624 user manual — Monitoring Stacks
Page 102 · click to enlarge
Page 102

Monitoring Stacks Managing OmniSwitch 6600 Series Stacks

Page 103 of the Alcatel-Lucent 6624 user manual — Declaration of Conformity: CE Mark
Page 103 · click to enlarge
Page 103

A Regulatory Compliance

and Safety Information

This appendix provides information on regulatory agency compliance and safety for the OmniSwitch 6600 Series.

Declaration of Conformity: CE Mark

This equipment is in compliance with the essential requirements and other provisions of Directive 73/23/EEC and 89/336/EEC as amended by Directive 93/68/EEC.

Français: Ce matériel est conformément aux conditions essentielles et à d'autres dispositions de 73/23/EEC et de 89/336/EEC directifs comme modifié par Directive 93/68/EEC.

Deutsch: Diese Ausrüstung ist gemäß den wesentlichen Anforderungen und anderen Bestimmungen rich- tungweisenden 73/23/EEC und des 89/336/EEC, wie von Directive 93/68/EEC geändert.

Español: Este directivo equipo está en conformidad con los requisitos esenciales y otras provisiones 73/23/EEC y 89/336/EEC según la enmienda prevista por Directive 93/68/EEC.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page A-1

Page 104 of the Alcatel-Lucent 6624 user manual — Safety and Environmental Standards
Page 104 · click to enlarge
Page 104

Standards Compliance Regulatory Compliance and Safety Information

Standards Compliance

The product bears the CE mark. In addition it is in compliance with the following other safety and EMC standards:

Safety Standards

  • UL 60950
  • CAN/CSA-C22.2 No. 60950-00
  • EN 60950
  • IEC 60950
  • TS 001
  • AS/NZS 3260
  • CB Certification PBR IEC 950

EMC Standards

  • FCC Part 15 (CFR 47) Class A/Class B
  • ICES-003 Class A/Class B
  • EN 55022 Class A/Class B
  • CISPR 22 Class A/Class B
  • AS/NZS 3548 Class A/Class B
  • VCCI Class A/Class B
  • EN 55024
  • EN 50082-1
  • EN 61000-3-2
  • EN 61000-3-3
  • EN 61000-4-2
  • EN 61000-4-3
  • EN 61000-4-4
  • EN 61000-4-5
  • EN 61000-4-6
  • EN 61000-4-8
  • ENC 1000-4-11

Safety and Environmental Standards

  • ETS 300 019 Storage Class 1.1
  • ETS 300 019 Transportation Class 2.3
  • ETS 300 019 Stationary Use Class 3.1

All hardware switching modules used in an OmniSwitch 6600 Series switches comply with Class A and Class B standards for digital devices per the FCC Part 15, ICES-003, EN 55022, CISPR 22, AS/NZS 3548, and VCCI standards. Modules with copper connectors meet Class A requirements using unshielded (UTP) cables, but meet Class B requirements using shielded (STP) cables.

page A-2 OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 105 of the Alcatel-Lucent 6624 user manual — CISPR22 Class A warning
Page 105 · click to enlarge
Page 105

Regulatory Compliance and Safety Information Standards Compliance

FCC Class A, Part 15

This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful inter- ference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this guide, may cause interference to radio communications.Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his own expense.

The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user’s authority to operate this equipment.It is suggested that the user use only shielded and grounded cables to ensure compliance with FCC Rules.

If this equipment does cause interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient the receiving antenna.
  • Relocate the equipment with respect to the receiver.
  • Move the equipment away from the receiver.
  • Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.

Canada Class A Statement

This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set out in the Radio Interference Regulation of the Canadian Department of Communications.

Avis de conformitè aux normes du ministère des Communications du Canada

Cet èquipement ne dèpasse pas les limites de Classe A d íèmission de bruits radioèlectriques pour les appareils numèriques,telles que prescrites par le RÈglement sur le brouillage radioèlectrique ètabli par le ministère des Communications du Canada.

JATE

This equipment meets the requirements of the Japan Approvals Institute of Telecommunications Equip- ment (JATE).

CISPR22 Class A warning

This is a Class A product. In a domestic environment, this product may cause radio interference. Under such circumstances, the user may be requested to take appropriate countermeasures.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page A-3

Page 106 of the Alcatel-Lucent 6624 user manual — Class A Warning for Taiwan and Other Chinese Markets
Page 106 · click to enlarge
Page 106

Standards Compliance Regulatory Compliance and Safety Information

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

Alcatel-Lucent 6624 — VCCI diagram (page 106)
Fig. 19

Class A Warning for Taiwan and Other Chinese Markets

This is a Class A Information Product. When used in a residential environment, it may cause radio frequency interference. Under such circumstances, the user may be requested to take appropriate counter- measure.

Alcatel-Lucent 6624 — Class A Warning for Taiwan and Other Chinese Markets diagram (page 106)
Fig. 20 · Class A Warning for Taiwan and Other Chinese Markets

page A-4 OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 107 of the Alcatel-Lucent 6624 user manual — Electrical Storm Warning
Page 107 · click to enlarge
Page 107

Regulatory Compliance and Safety Information Translated Safety Warnings

Translated Safety Warnings

Chassis Lifting Warning

Two people are required when lifting the chassis. Due to its weight, lifting the chassis unassisted can cause personal injury. Also be sure to bend your knees and keep your back straight when assisting with the lifting of the chassis.

Français: Deux personnes sont priées en soulevant le châssis. En raison de son poids, le levage du châs- sis sans aide peut causer injury. Also personnel soit sûr de déplier vos genoux et de garder votre arrière directement en assistant le levage du châssis.

Deutsch: Zwei Leute werden benoetigt, wenn man das Chassis anhebt. Wegen seines Gewichts, kann das Anheben des Chassis Personenschäden unassisted verursachen. Seien Sie auch sicher, Ihre Knie zu verbiegen und Ihr rückseitiges gerade zu halten bei der Unterstützung mit dem Anheben des Chassis.

Español: Requieren a dos personas al levantar el chasis. debido a su peso, la elevación del chasis puede causar sin ayuda daños corporales. También sea seguro doblar sus rodillas y guardar su posterior derecho al asistir con la elevación del chasis.

Blank Panels Warning

Because they regulate airflow and help protect internal chassis components, blank cover plates should remain installed at empty module slots and power supply bays at all times.

Français: Puisqu'ils règlent le flux d'air et aident à protéger les composants internes de châssis, les couvercles blanc devraient rester installés aux fentes vides de module et l'alimentation d'énergie aboie à tout moment.

Deutsch: Weil sie Luftstrom regeln und helfen, interne Chassisbestandteile zu schützen, sollten unbelegte Deckplatten installiert an den leeren Modulschlitzen bleiben und Spg.Versorgungsteil bellt ständig.

Español: Porque regulan la circulación de aire y ayudan a proteger componentes internos del chasis, las tapaderas en blanco deben seguir instaladas en las ranuras vacías del módulo y la fuente de alimentación ladra siempre.

Electrical Storm Warning

To avoid a shock hazard, do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.

Français: Pour éviter tout risque de choc électrique, ne manipulez aucun câble et n’effectuez aucune opération d’installation, d’entretien ou de reconfiguration de ce produit au cours d’un orage.

Deutsch: Um gefährliche Spannungen zu vermeiden, dürfen während eines Gewitters an diesem Gerät keine Kabel angeschlossen oder gelöst werden, ferner keine Installation, Wartung oder Rekonfiguration durchgeführt werden.

Español: Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna insta- lación, maintenimiento o reconfiguratión de este producto durante una tormenta eléctrica.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page A-5

Page 108 of the Alcatel-Lucent 6624 user manual — Invisible Laser Radiation Warning
Page 108 · click to enlarge
Page 108

Translated Safety Warnings Regulatory Compliance and Safety Information

Installation Warning

Only personnel knowledgeable in basic electrical and mechanical procedures should install or maintain this equipment.

Français: Seulement le personnel bien informé des procédures électriques et mécaniques de base devrait installer ou mettre à jour ce matériel.

Deutsch: Das nur Personal, das in den grundlegenden elektrischen und mechanischen Prozeduren kennt- nisreich ist, sollte diese Ausrüstung installieren oder beibehalten.

Español: Solamente el personal bien informado en procedimientos eléctricos y mecánicos básicos debe instalar o mantener este equipo.

Invisible Laser Radiation Warning

Lasers emit invisible radiation from the aperture opening when no fiber-optic cable is connected. When removing cables do not stare into the open apertures. In addition, install protective aperture covers to fiber ports with no cable connected.

Français: Les lasers émettent le rayonnement invisible de l'ouverture d'ouverture quand aucun câble fiber- optic n'est relié. En enlevant des câbles ne regardez pas fixement dans les ouvertures ouvertes. En outre, installez les couvertures protectrices d'ouverture sur des ports de fibre sans le câble relié.

Deutsch: Laser strahlen unsichtbare Strahlung von der Blendenöffnung Öffnung aus, wenn kein Glas- faserkabel angeschlossen wird. Wenn Sie Kabel löschen, starren Sie nicht in die geöffneten Blendenöff- nungen an. Zusätzlich installieren Sie schützende Blendenöffnung Abdeckungen zu den Faserkanälen ohne das angeschlossene Kabel.

Español: Los lasers emiten la radiación invisible de la apertura de la abertura cuando no se conecta ningún cable fiber-optic. Al quitar los cables no mire fijamente en las aberturas abiertas. Además, instale las cubi- ertas protectoras de la abertura a los accesos de la fibra sin el cable conectado.

page A-6 OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 109 of the Alcatel-Lucent 6624 user manual — Operating Voltage Warning
Page 109 · click to enlarge
Page 109

Regulatory Compliance and Safety Information Translated Safety Warnings

Lithium Battery Warning

There is a danger of explosion if the Lithium battery in your chassis is incorrectly replaced. Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows: Return the module with the Lithium battery to Alcatel. The Lithium battery will be replaced at Alcatel’s factory.

Français: Il y a un danger d'explosion si la batterie de lithium dans votre châssis est inexactement substi- tuée. Substituez la batterie seulement avec la même chose ou le type équivalent de batterie recommandé par le constructeur. Rejetez les batteries utilisées selon les instructions du constructeur. Les instructions du constructeur sont comme suit : Renvoyez le module avec la batterie de lithium à Alcatel. La batterie de lithium sera substituée à l'usine d'Alcatel.

Deutsch: Es gibt eine Gefahr der Explosion, wenn die Lithiumbatterie in Ihrem Chassis falsch ersetzt wird. Ersetzen Sie die Batterie nur mit gleichen oder dem gleichwertigen Typen der Batterie empfohlen durch den Hersteller. Entledigen Sie sich benutzte Batterien entsprechend den Anweisungen des Herstell- ers. Die Anweisungen des Herstellers sind, wie folgt: Bringen Sie das Modul mit der Lithiumbatterie zu Alcatel zurück. Die Lithiumbatterie wird an der Fabrik Alcatels ersetzt.

Español: Hay un peligro de la explosión si la batería del litio en su chasis se substituye incorrectamente. Substituya la batería solamente por el mismo o el tipo equivalente de batería recomendado por el fabri- cante. Disponga de las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabri- cante son como sigue: Vuelva el módulo con la batería del litio a Alcatel. La batería del litio será substituida en la fábrica de Alcatel.

Dansk: ADVARSEL! Lithiumbatteri--Eksplosionsfare ved fejlagtig handtering. Udskiftning ma kun ske batteri af samme fabrikat og type. Lever det brugte batteri tilbage tilleverandoren.

Operating Voltage Warning

To reduce the risk of electrical shock, keep your hands and fingers out of power supply bays and do not touch the backplane while the switch is operating.

Français: Pour réduire le risque de choc électrique, gardez vos mains et doigts hors des compartiments d'alimentation d'énergie et ne touchez pas la surface arrière tandis que le commutateur fonctionne.

Deutsch: Um die Gefahr des elektrischen Schlages zu verringern, halten Sie Ihre Hände und Finger aus Spg.Versorgungsteilbuchten heraus und berühren Sie nicht die Rückwandplatine während der Schalter steuert.

Español: Para reducir el riesgo del choque eléctrico, guarde sus manos y dedos fuera de bahías de la fuente de alimentación y no toque la placa madre mientras que el interruptor está funcionando.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page A-7

Page 110 of the Alcatel-Lucent 6624 user manual — Proper Earthing Requirement Warning
Page 110 · click to enlarge
Page 110

Translated Safety Warnings Regulatory Compliance and Safety Information

Power Disconnection Warning

Your switch is equipped with multiple power supplies. To reduce the risk of electrical shock, be sure to disconnect all power connections before servicing or moving the unit.

Français: Votre commutateur est équipé des alimentations d'énergie multiples. Pour réduire le risque de choc électrique, soyez sûr de débrancher toutes les connexions de puissance avant d'entretenir ou déplacer l'unité.

Deutsch: Ihr Schalter wird mit mehrfachen Spg.Versorgungsteilen ausgerüstet. Um die Gefahr des elek- trischen Schlages zu verringern, seien Sie sicher alle Stromanschlüsse zu trennen bevor Sie die Maßein- heit instandhalten oder verschieben.

Español: Su interruptor se equipa de las fuentes de alimentación múltiples. Para reducir el riesgo del choque eléctrico, sea seguro desconectar todas las conexiones de potencia antes de mantener o de mover la unidad.

Proper Earthing Requirement Warning

To avoid shock hazard:

  • The power cord must be connected to a properly wired and earth receptacle.
  • Any equipment to which this product will attached must also be connected to properly wired receptacles.
FrançaisPour éviter tout risque de choc électrique:
  • Le cordon d’alimentation doit être branché sur une prise d’alimentation correctement câblée et mise à la terre.
  • D’autre part, tout le matériel connecté à ce produit doit également être branché sur des prises d’alimentation correctement câblées et mises à la terre.
DeutschAus Sicherheitsgründen:
  • darf das Netzkabel nur an eine Schutzkontaktsteckdose angeschloossen werden.
  • dürfen für den Anschluß anderer Geräte an den Drucker auch nur Schutzkontaktsteckdosen verwendet wereden.
EspañolPara evitar peligro de descargas:
  • El cable de alimentación debe estar conectado a una toma de alimentación adecuadamente cableada y con toma de tierra.
  • Cualquier equipo al cual se conecte este producto debe estar también conectado a tomas de alimentación adecuadamente cableadas.

page A-8 OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 111 of the Alcatel-Lucent 6624 user manual — Restricted Access Location Warning
Page 111 · click to enlarge
Page 111

Regulatory Compliance and Safety Information Translated Safety Warnings

Read Important Safety Information Warning

The Getting Started Guide that accompanied this equipment contains important safety information about which you should be aware when working with hardware components in this system. You should read this guide before installing, using, or servicing this equipment.

Français: Le Getting Started Guide qui a accompagné ce matériel contient l'information importante de sûreté au sujet dont vous devriez vous rendre compte en travaillant avec des composants de matériel dans ce système. Vous devriez lire ce guide avant d'installer, à l'aide, ou entretenir de ce matériel.

Deutsch: Die Getting Started Guide, die diese Ausrüstung begleitete, enthält wichtige Sicherheit Informa- tionen, über die Sie beim Arbeiten bewußt sein sollten mit Hardwareeinheiten in diesem System. Sie sollten diese Anleitung lesen, bevor Sie installieren, verwenden, oder instandhalten diese Ausrüstung.

Español: La Getting Started Guide que acompañó este equipo contiene la información importante de seguridad sobre la cual usted debe estar enterado al trabajar con los componentes de dotación física en este sistema. Usted debe leer esta guía antes de instalar, de usar, o de mantener este equipo.

Restricted Access Location Warning

This equipment should be installed in a location that restricts access. A restricted access location is one where access is secure and limited to service personnel who have a special key, or other means of security.

Français: Ce matériel devrait être installé dans un emplacement qui limite l'accès. Un emplacement restreint d'accès est un où l'accès est bloqué et limité au personnel de service qui ont une clé spéciale, ou à d'autres moyens de sécurité.

Deutsch: Diese Ausrüstung sollte in einen Standort installiert werden, der Zugriff einschränkt. Ein einge- schränkter Zugriff Standort ist einer, wo Zugriff befestigen und an Service-Personal, das eine spezielle Taste haben, oder an andere Mittel der Sicherheit begrenzt ist.

Español: Este equipo se debe instalar en una localización que restrinja el acceso. Una localización restricta del acceso es una donde está seguro y limitado el acceso al personal de servicio que tiene un clave especial, o a otros medios de la seguridad.

OmniSwitch 6600 Series Hardware Users Guide April 2004 page A-9

Page 112 of the Alcatel-Lucent 6624 user manual — Wrist Strap Warning
Page 112 · click to enlarge
Page 112

Translated Safety Warnings Regulatory Compliance and Safety Information

Wrist Strap Warning

Because electrostatic discharge (ESD) can damage switch components, you must ground yourself prop- erly before continuing with the hardware installation. For this purpose, Alcatel provides a grounding wrist strap and a grounding lug located near the top-right of the chassis. For the grounding wrist strap to be effective in eliminating ESD, the power supplies must be installed in the chassis and plugged into grounded AC outlets.

Français: Puisque la décharge électrostatique (ESD) peut endommager des composants de commutateur, vous devez vous rectifier correctement avant de continuer l'installation de matériel. À cette fin, Alcatel fournit une courroie de poignet fondante et une patte de mise à la terre située près du dessus-droit du châs- sis. Pour que la courroie de poignet fondante soit pertinente en éliminant ESD, les alimentations d'énergie doivent être installées dans le châssis et être branchées aux sorties au sol à C.A.

Deutsch: Weil elektrostatische Entladung (ESD) Schalterbestandteile beschädigen kann, müssen Sie rich- tig sich reiben, bevor Sie mit der Hardwareinstallation fortfahren. Zu diesem Zweck stellt Alcatel eine erdenhandgelenkbrücke und eine Erdungsöse zur Verfügung, die nahe dem Oberseite-rechten des Chassis gelegen sind. Damit die erdenhandgelenkbrücke wirkungsvoll ist, wenn man ESD beseitigt, die Spg.Versorgungsteile muß in das Chassis installiert werden und eingesteckt werden in geerdete Wechsel- strom Anschlüsse.

Español: Porque la descarga electrostática (ESD) puede dañar componentes del interruptor, usted debe molerse correctamente antes de continuar con la instalación de dotación física. Para este propósito, Alca- tel proporciona a una correa de muñeca que pone a tierra y a un terminal que pone a tierra situados cerca del tapa-derecho del chasis. Para que la correa de muñeca que pone a tierra sea eficaz en la eliminación de ESD, las fuentes de alimentación se deben instalar en el chasis y tapar en los enchufes puestos a tierra de la CA.

page A-10 OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 114 of the Alcatel-Lucent 6624 user manual — OS6600-GNI-C2 2-27 OS6600-GNI-U2 2-25
Page 114 · click to enlarge
Page 114

OS6600-GNI-U2 2-25 technical specifications 2-26 OS6600-U24

resiliency and redundancy 3-4 slot numbers 3-4 specifications 3-2 topology 3-19

see OmniSwitch 6600-U24 OS6624

see OmniSwitch 6624 OS6648

T takeover command 3-18 technical specifications

10/100 Ethernet ports 2-4, 2-10 100 Ethernet SFP ports 2-8 back up power supply 2-18 console port 2-49, 2-50, 2-51 MiniGBICs 2-34 OmniSwitch 6600-U24 2-7 OmniSwitch 6624 2-4 OmniSwitch 6648 2-10 OS6600-GNI-C2 2-27 OS6600-GNI-U2 2-26 pinouts 2-49 SFPs 2-38 stacking module 2-28 temperature management 2-42 danger threshold 2-44 errors 2-44 fan status 2-45 monitoring chassis temperature 2-42 warning threshold 2-44 temp-threshold command 2-44

P pinouts 2-49 port capacities 1-5 power cords 2-17 power supplies 2-18 back up power supply 2-18 power cords 2-17 redundant AC circuits and 2-19

AC circuit 2-19 back up power supply 2-18 CMM roles 3-5 commands supported on secondary switch 3-6 reload all command 3-18 reload command 3-16

S SFPs 2-38 SFP-100-LC-MM 2-38 SFP-100-LC-SM15 2-38 SFP-100-LC-SM40 2-38 SFP-100-MTRJ-MM 2-39 technical specifications 2-38 show chassis command 2-58 show cmm command 2-57 show fan command 2-44, 2-45 show hardware info command 2-53 show mac-range command 2-60 show module command 2-54 show module long command 2-55 show ni command 2-55 show power command 2-23 show running-directory command 3-18 show stack topology command 3-19 show temperature command 2-42 Smart Continuous Switching 1-3 software rollback 1-4 stacking module

OS6600-GNI-C2 2-27 OS6600-GNI-U2 2-25

technical specifications 2-28 stacks 3-1 boot.slot.cfg file 3-4 CMM roles 3-5 default values 3-2 managing 3-16 monitoring 3-19 overview 3-3

Index-2 OmniSwitch 6600 Series Hardware Users Guide

Show 4 more labels / short text on this page
Index · see OmniSwitch 6648 · R redundancy · U uplink modules
Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
OK1Hardware Status. Dis- p.31
OK2Software Status. Blinks p.31
PS1Displays solid green p.31
PS2Displays solid green p.31

Ask about the Alcatel-Lucent 6624

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Alcatel-Lucent 6624

Be the first to ask — other owners or our team will answer.

Original document

Alcatel-Lucent 6624 manual PDF

114 pages·3.9 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…