Part No. 060181-10, Rev. G September 2006
Hardware Users Guide

chassis and associated components. The specifications described in this guide are subject to change without notice.
Copyright © 2006 by Alcatel Internetworking, Inc. All rights reserved. This document may not be repro- duced in whole or in part without the express written permission of Alcatel Internetworking, Inc.
Alcatel® and the Alcatel logo are registered trademarks of Alcatel. Xylan®, OmniSwitch®, OmniStack®, and Alcatel OmniVista® are registered trademarks of Alcatel Internetworking, Inc.
OmniAccess™, Omni Switch/Router™, PolicyView™, RouterView™, SwitchManager™, VoiceView™, WebView™, X-Cell™, X-Vision™, and the Xylan logo are trademarks of Alcatel Internetworking, Inc.
This OmniSwitch product contains components which may be covered by one or more of the following U.S. Patents:
US Customer Support—(800) 995-2696 International Customer Support—(818) 878-4507
Internet—http://eservice.ind.alcatel.com
ii OmniSwitch 6600 Family Hardware Users Guide September 2006


This OmniSwitch 6600 Family Hardware Users Guide describes your switch hardware components and basic switch hardware procedures.
This information in this guide applies to the following products:
OmniSwitch 6600 Family switches are next generation enterprise edge/workgroup switches. The OmniSwitch 6624 and 6602-24 offer 24 copper 10/100 ports, the 6600-P24 offers 24 copper 10/100 Power over Ethernet (PoE) ports, the 6648 and 6602-48 offer 48 copper 10/100 ports, and the 6600-U24 offers 24 fiber 100 ports.
In addition, OmniSwitch 6624/6600-U24/6648 switches have one expansion port that can be used for a Gigabit Ethernet uplink module and another expansion port that can be used for a Gigabit Ethernet uplink or a stacking module while the 6602-24/6602-48 switches offer fixed Gigabit Ethernet uplinks and fixed stacking ports. The stacking ports on all OmniSwitch 6600 Family switches allow two to eight OmniSwitch 6600 Family switches to be configured as one virtual chassis known as a stack.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page ix

Supported Platforms About This Guide
The information in this guide does not apply to the following products:
page x OmniSwitch 6600 Family Hardware Users Guide September 2006

About This Guide Who Should Read this Manual?
The audience for this users guide is network administrators and IT support personnel who need to config- ure, maintain, and monitor switches and routers in a live network. However, anyone wishing to gain knowledge on the OmniSwitch 6600 Family hardware will benefit from the material in this guide.
Read this guide as soon as you are ready to familiarize yourself with your switch hardware components. You should have already stepped through the first login procedures and read the brief hardware overviews in the OmniSwitch 6600 Family Getting Started Guide.
You should already be familiar with the very basics of the switch hardware, such as module LEDs and module installation procedures. This manual will help you understand your switch hardware components (chassis, cooling fans, power supplies, Gigabit uplink modules, stacking modules, backup power supplies) in greater depth.
This users guide includes the following hardware-related information:
The descriptive and procedural information in this manual focuses on switch hardware. It includes infor- mation on some CLI commands that pertain directly to hardware configuration, but it is not intended as a software users guide. There are several OmniSwitch 6600 Family users guides that focus on switch soft- ware configuration. Consult those guides for detailed information and examples for configuring your switch software to operate in a live network environment. See “Documentation Roadmap” on page -xii and “Related Documentation” on page -xiv for further information on software configuration guides avail- able for your switch.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page xi

How is the Information Organized? About This Guide
This users guide provides an overview of OmniSwitch 6600 Family switches in the first chapter, an over- view and procedures for setting up and managing OmniSwitch 6600 Family switches in the second chap- ter, and an overview and procedures for setting up and managing stacks in the third chapter.
The OmniSwitch user documentation suite was designed to supply you with information at several critical junctures of the configuration process.The following section outlines a roadmap of the manuals that will help you at each stage of the configuration process. Under each stage, we point you to the manual or manuals that will be most helpful to you.
A hard-copy OmniSwitch 6600 Family Getting Started Guide is included with your switch; this guide provides all the information you need to get your switch up and running the first time. This guide provides information on unpacking the switch, rack mounting the switch, installing uplink and stacking modules, unlocking access control, setting the switch’s IP address, setting up a password, and setting up stacks. It also includes succinct overview information on fundamental aspects of the switch, such as hardware LEDs, the software directory structure, stacking, CLI conventions, and web-based management.
At this time you should also familiarize yourself with the Release Notes that accompanied your switch. This document includes important information on feature limitations that are not included in other user guides.
OmniSwitch 6600 Family Switch Management Guide
Once you have your switch up and running, you will want to begin investigating basic aspects of its hard ware and software. Information about switch hardware is provided in the OmniSwitch 6600 Family Hard- ware Users Guide. This guide provide specifications, illustrations, and descriptions of all hardware components–chassis, power supplies, uplink and stacking modules, and cooling fans. It also includes steps for common procedures, such as removing and installing switch modules.
The OmniSwitch 6600 Family Switch Management Guide is the primary user guide for the basic software features on a single switch. This guide contains information on the switch directory structure, basic file and directory utilities, switch access security, SNMP, and web-based management. It is recommended that you read this guide before connecting your switch to the network.
page xii OmniSwitch 6600 Family Hardware Users Guide September 2006
Release Notes

About This Guide Documentation Roadmap
OmniSwitch 6600 Family Advanced Routing Configuration Guide
When you are ready to connect your switch to the network, you will need to learn how the OmniSwitch implements fundamental software features, such as 802.1Q, VLANs, and Spanning Tree. The OmniSwitch 6600 Family Network Configuration Guide contains overview information, procedures and examples on how standard networking technologies are configured in the OmniSwitch 6600 Family.
The OmniSwitch 6600 Family Advanced Routing Configuration Guide includes configuration information for networks using Open Shortest Path First (OSPF).
The OmniSwitch CLI Reference Guide contains comprehensive information on all CLI commands supported by the switch. This guide includes syntax, default, usage, example, related CLI command, and CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can be consulted anytime during the configuration process to find detailed and specific information on each CLI command.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page xiii

Related Documentation About This Guide
The following are the titles and descriptions of all the OmniSwitch 6600 Family user manuals:
Describes the hardware and software procedures for getting an OmniSwitch 6600 Family switch up and running. Also provides information on fundamental aspects of OmniSwitch software and stacking architecture.
Complete technical specifications and procedures for all OmniSwitch 6600 Family chassis, power supplies, fans, and uplink and stacking modules.
Complete reference to all CLI commands supported on the OmniSwitch 6624, 6600-U24, 6600-P24, 6648, 6602-24, 6602-48, 7700, 7800, and 8800. Includes syntax definitions, default values, examples, usage guidelines and CLI-to-MIB variable mappings.
Includes procedures for readying an individual switch for integration into a network. Topics include the software directory architecture, image rollback protections, authenticated switch access, managing switch files, system configuration, using SNMP, and using web management software (WebView).
Includes network configuration procedures and descriptive information on all the major software features and protocols included in the base software package. Chapters cover Layer 2 information (Ethernet and VLAN configuration), Layer 3 information, security options (authenticated VLANs), Quality of Service (QoS), and link aggregation.
Includes network configuration procedures and descriptive information on all the software features and protocols included in the advanced routing software package. Chapters cover the Open Shortest Path First (OSPF) Protocol.
Includes information published by Alcatel’s Customer Support group.
Includes critical Open Problem Reports, feature exceptions, and other important information on the features supported in the current release and any limitations to their support.
page xiv OmniSwitch 6600 Family Hardware Users Guide September 2006

About This Guide User Manual CD
All user guides for the OmniSwitch 6600 Family are included on the User Manual CD that accompanied your switch. This CD also includes user guides for other Alcatel data enterprise products. In addition, it contains a stand-alone version of the on-line help system that is embedded in the OmniVista network management application.
Besides the OmniVista documentation, all documentation on the User Manual CD is in PDF format and requires the Adobe Acrobat Reader program for viewing. Acrobat Reader freeware is available at www.adobe.com
To verify that you are using Acrobat Reader with the global search option, look for the following button in the toolbar:
An Alcatel service agreement brings your company the assurance of 7x24 no-excuses technical support. You’ll also receive regular software updates to maintain and maximize your Alcatel product’s features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel’s Service and Support web page, you’ll be able to view and update any case (open or closed) that you have reported to Alcatel’s technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more infor- mation on Alcatel’s Service Programs, see our web page at www.ind.alcatel.com call us at 1-800-995- 2696, or email us at support@ind.alcatel.com.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page xv

Technical Support About This Guide
page xvi OmniSwitch 6600 Family Hardware Users Guide September 2006

The OmniSwitch 6600 Family switches consist of the OmniSwitch 6624 (OS6624), OmniSwitch 6600- U24 (OS6600-U24), OmniSwitch 6600-P24 (OS6600-P24), OmniSwitch 6648 (OS6648), OmniSwitch 6602-24 (OS6602-24), and the OmniSwitch 6602-48 (OS6602-48). The OmniSwitch 6600 Family switches are next generation enterprise edge/workgroup switches. These switches are based on the same software architecture as OmniSwitch 7000 and 8000 Family switches (i.e., OS7700, OS7800, and OS8800) and are designed to meet the most stringent network requirements for mission-critical networks.
OmniSwitch 6600 Family switches are optimized for voice and data integration and provide non-blocking multi-Gigabit Ethernet capacity. Additional features include Carrier-class intelligence, best of breed QoS, Carrier-class resiliency, network management, and advanced policy-based VLANs and security. OmniSwitch 6600 Family switches also support wirespeed Layer 2 and Layer 3 switching, industry-based standards, and a full array of reliability, redundancy and resiliency capabilities.

Stand-Alone and Stacked Configurations OmniSwitch 6600 Family
A stand-alone OmniSwitch 6600 Family switch is ideal for small and medium-sized network edge applica- tions, offering 24 10/100 copper ports, 24 100 fiber ports, or 48 10/100 copper Power over Ethernet (PoE) ports. These switches provide support for enterprise-based devices, such as computer workstations or IP telephones.
A single OmniSwitch 6600 Family switch also supports two Gigabit Ethernet uplinks for high-bandwidth connections to a backbone or server.
In addition to working as individual, stand-alone switches, OmniSwitch 6600 Family switches can also be linked together to form a single, high-density virtual chassis known as a stack.
Stacking switches provides scalability by allowing users to quickly and easily expand 10/100 port density. Twenty-four 10/100 ports are added for each OS6624 or OS6602-24 brought into the stack; twenty-four 10/100 Power over Ethernet (PoE) ports are added for each OS6600-P24 brought into the stack; twenty- four 100 ports are added for each OS6600-U24 brought into the stack; forty-eight 10/100 ports are added for each OS6648 or OS6602-48.
Up to eight switches can be stacked. OmniSwitch 6600 Family switches can be mixed and matched in any combination within the stack. This provides a virtual chassis with a 10/100 or 100 capacity of up to 384 ports.
As with the stand-alone configuration, a stacked virtual chassis configuration provides Gigabit Ethernet uplinks to a backbone or server.
Note on Terminology. In the user manuals provided with your switch, the terms switch, slot and NI (Network Interface) refer to individual OmniSwitch 6600 Family units in standalone mode or within a stacked configuration. The term CMM (Chassis Management Module) refers to stacked OmniSwitch 6600 Family units operating in primary or secondary CMM roles. (An OmniSwitch 6600 Family switch operat- ing in an idle CMM role would normally be referred to as a switch, slot, or, NI.)
page 1-2 OmniSwitch 6600 Family Hardware Users Guide September 2006

OmniSwitch 6600 Family Availability Features
The switch provides a broad variety of Availability features. Availability features are hardware- and software-based safeguards that help prevent the loss of data flow in the unlikely event of a subsystem fail- ure. In addition, some Availability features allow you to maintain or replace hardware components with- out powering off your switch or interrupting switch operations. Combined, these features provide added resiliency and help ensure that your switch is consistently available for your day-to-day network opera- tions.
Hardware-related Availability features include:
In stacked configurations, one OmniSwitch 6600 Family switch is designated as the primary “manage- ment module” for the stack. Because the stack can be thought of as a virtual chassis, the role of this primary management switch is to monitor and manage the functions of the stack.
Similar to chassis-based switches such as the OmniSwitch 7700 and Omniswitch 7800, the stack also allows users to assign an additional switch as a secondary management module. As with the OS7700 and OS7800, the stack’s secondary switch immediately takes over management functions in the event of a primary switch failure.
All other switches in the stack are considered idle, and act very much like Ethernet Network Interface (ENI) modules in OS7700 and OS7800 switches, in that they provide Ethernet ports for 10/100 traffic.
The stack provides support for all idle switches during primary-to-secondary failover. In other words, if the stack’s primary switch fails or goes offline for any reason, all idle switches will continue data trans- mission during the secondary switch’s takeover process. This Availability feature is referred to as Smart Continuous Switching.
Incoming Layer 2 packets will continue to be sent to the appropriate egress port during failover. Spanning Tree will continue handling BPDUs received on the switch ports, as well as port link up and down states. The Spanning Tree topology will not be disrupted.
For more information on primary, secondary, and idle switches, as well as the failover process, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”

Availability Features OmniSwitch 6600 Family
Software rollback (also referred to as image rollback) essentially allows the OmniSwitch 6600 Family switches (in both standalone and stacked configurations) to return to a prior “last known good” version of software in the event of a system software problem. The switch controls software rollback through its resilient directory structure design (i.e., /flash/working and /flash/certified).
For detailed information on the software rollback feature, as well as the switch’s /flash/working and /flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6600 Family Switch Management Guide.
Hot swapping refers to the action of adding, removing, or replacing back up power supplies, as well as uplink modules and MiniGBICs, without powering off your switch and disrupting other components in the switch or stack. This feature greatly facilitates hardware upgrades and maintenance and also allows you to easily replace components in the unlikely event of hardware failure. The following hardware components can be hot swapped:
- SFP-100-LC-SM15
- SFP-100-LC-SM40
- SFP-100-MTRJ-MM
For instructions on hot swapping back up power supplies, uplink modules, and MiniGBICs, refer to Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components.”
page 1-4 OmniSwitch 6600 Family Hardware Users Guide September 2006
- MiniGBIC-SX · - MiniGBIC-LX · - MiniGBIC-LH-70

OmniSwitch 6600 Family Availability Features
Automatic monitoring refers to the switch’s built-in sensors that automatically monitor operations. If an error is detected (e.g., over-threshold temperature), the switch immediately sends a trap to the user. The trap is displayed on the console in the form of a text error message. (In the case of an over-threshold temperature condition, the chassis displays an amber TEMP LED in addition to sending a trap.)
LEDs, which provide visual status information, are provided on the chassis front panel. LEDs are used to indicate conditions such as hardware and software status, temperature errors, link integrity, data flow, etc. For detailed LED descriptions, refer to Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components.”
User-driven hardware monitoring refers to CLI commands that are entered by the user in order to access the current status of hardware components. The user enters “show” commands that output information to the console. Monitoring information for chassis components such as the optional back up power supply, chassis temperature sensor, and chassis fans is provided in Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components.” Show commands for all features are described in detail in the OmniSwitch CLI Reference Guide.

Application Examples OmniSwitch 6600 Family
The following application examples show two of the many ways OmniSwitch 6600 Family switches can be used in an enterprise network setting.
The following diagram shows converged voice and data applications, with 1000 users, in a single building enterprise environment. Edge devices consist of a mixture of PCs and IP telephones. In this example, a single OmniPCX 4400 in the core supports IP voice initiations and terminations. An OmniSwitch 7800 switch provides a port density of 1000 10/100 ports. The stackable OmniSwitch 6600 Family configura- tions provide redundant and dual connectivity from the edge to the redundant backbone/core, in which the OmniSwitch 7800 core switches are used.
IP Phones IP Phones
OmniSwitch 7800 Gigabit Gigabit
OmniSwitch 7800 OmniSwitch 7800
page 1-6 OmniSwitch 6600 Family Hardware Users Guide September 2006

OmniSwitch 6600 Family Application Examples
This example illustrates converged voice and data applications with 1500 users spread across two build- ings in an enterprise campus. Edge devices consist of a mixture of PCs and IP telephones. And, like the previous example, a single OmniPCX 4400 in the core supports IP voice initiations and terminations.
In building number one, an OmniSwitch 7800 switch provides a port density of 1000 10/100 ports, and the stackable OmniSwitch 6600 Family configurations provide redundant and dual connectivity from the edge to the redundant backbone/core. In building number two, the stackable OmniSwitch 6600 Family configu- rations provide 500 ports for connectivity from the edge to the backbone/core.
10/100
OmniSwitch 7800 OmniSwitch 7800
Building Number One Building Number Two

Application Examples OmniSwitch 6600 Family
page 1-8 OmniSwitch 6600 Family Hardware Users Guide September 2006

Components
OmniSwitch 6600 Family switches are available in six stackable chassis configurations—the 24-port OmniSwitch 6624 (OS6624), OmniSwitch 6600-U24 (OS6600-U24), OmniSwitch 6600-P24 (OS6600- P24), and OmniSwitch 6602-24 (OS6602-24) and the 48-port OmniSwitch 6648 (OS6648) and OmniSwitch 6602-48 (OS6602-48). This chapter includes detailed information on each of these chassis types. Topics include:

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6624
The OS6624 is a stackable edge/workgroup switch offering 24 10/100 Ethernet ports. The OS6624 can also be equipped with upto four Gigabit Ethernet ports for connections to a high speed backbone or server.
The front panel of the OS6624 chassis contains the following major components:
Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.
Console Port The OS6624 front panel provides one RS232 port for console connections. Serial console connections are used by network administrators for switch management. This female DB-9 con- nector provides a DCE console connection.
Gigabit Ethernet Uplink Module Slot The OS6624 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:
EXPANSION/STACKING EXPANSION 25 26 27 28
OK1
PS1
PRI
TEMP
LINK/ACT LINK/ACT LINK/ACT LINK/ACT
OK2
PS2
SEC
FAN SEL
Status and Slot Indicator LEDs For information on the OS6624’s status and slot indicator LEDs, refer to page 2-18.
10/100 Ethernet Ports The OS6624 provides 24 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.
Stacking or Uplink Module Slot The OS6624 provides an additional slot that can accommodate either a stacking module or a Gigabit Ethernet uplink module.
Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed infor- mation.
If you use a Gigabit Ethernet uplink module in this slot, the OS6624 must be used as a stand-alone switch.
A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
TM OmniSwitch 6624

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6624
Total number of 10/100 Mbps ports per switch
Total number of Gigabit Ethernet ports per switch
4 (for stand-alone switches); 2 (for stacked configurations)
Total number of 10/100 Mbps ports per stack
192 (stack of eight switches)
Total number of Gigabit Ethernet ports per stack
16 (stack of eight switches)
Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate
Current draw Approximately 2.3 Amps
Power Approximately 55 Watts
Total available power supplies 2 (one factory-installed power supply and one optional backup power supply)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
19.125 inches
Chassis Width (rack-mount flanges not included)
17.2 inches
Height 2.65 inches
Height (rack units) 1.5 RU
Chassis Depth 14 inches
Chassis Weight Approximately 12 lbs (13.5 lbs with optional backup power supply installed)
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)
Standards supported IEEE 802.3u, IAB RFCs 826, 894
Data rate 10 or 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Connections supported 10BaseT hub or device; 100BaseTX hub or device
Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm
Maximum cable distance 100 meters
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-U24
The OS6600-U24 is a stackable edge/workgroup switch offering 24 fiber 100 Mbps Ethernet SFP ports. The OS6600-U24 can also be equipped with up to four Gigabit Ethernet ports for connections to a high speed backbone or server.
The front panel of the OS6600-U24 chassis contains the following major components:
The following SFP transceivers are available for the OS6600-U24:
Refer to the illustration on the following page for more front panel information. For detailed LED descrip- tions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-U24
Console Port The OS6600-U24 front panel provides one RJ-45 port for console connections. Serial console con- nections are used by network administrators for switch management. This female RJ-45connector provides a DCE console connection.
Gigabit Ethernet Uplink Module Slot The OS6600-U24 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:
3 5 7 9 11 13 15 17 19 21 23 1
CONSOLE
SEL
OK1
PS1
LINK/ACT LINK/ACT 2 24
OK2
PS2 PRI SEC TEMP FAN
2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23
Status and Slot Indicator LEDs For information on the OS6600-U24’s status and slot indicator LEDs, refer to page 2-18.
100 Fiber Ethernet SFP Ports The OS6600-U24 provides 24 fiber 100 Ethernet SFP ports. These ports can use the SFP-100- LC-MM, SFP-100-LC-SM, and SFP-100-MTRJ-MM transceivers in any combination.
Stacking or Uplink Module Slot The OS6600-U24 provides an additional slot that can accommodate either a stacking mod- ule or a Gigabit Ethernet uplink module.
Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed infor- mation.
If you use a Gigabit Ethernet uplink module in this slot, the OS66600-U24 must be used as a stand-alone switch.
A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
TM OmniSwitch 6600-U24

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-U24
Total number of 100 Mbps SFP ports per switch
Total number of Gigabit Ethernet ports per switch
4 (for stand-alone switches); 2 (for stacked configurations)
Total number of 100 Mbps SFP ports per stack
192 (stack of eight switches)
Total number of Gigabit Ethernet ports per stack
16 (stack of eight switches)
Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate
Power The OS6600-U24 power supply provides 100 W
Total available power supplies 2 (one factory-installed power supply and one optional backup power supply)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
19.125 inches
Chassis Width (rack-mount flanges not included)
17.2 inches
Height 2.65 inches
Height (rack units) 1.5 RU
Chassis Depth 14 inches
Chassis Weight Approximately 11.56 lbs not including uplink/stacking modules or SFPs (13.06 lbs with optional backup power supply installed)
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-U24
Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)
Data rate 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Cable supported SFP-100-LC-MM: 62.5/125 and 50/125 micron multimode fiber SFP-100-LC-SM: 9/125 micron single mode SFP-100-MTRJ-MM: 62.5/125 and 50/125 micron multimode fiber
-22.5 to -14 dBm (50/125 micron) SFP-100-LC-SM15: -15 to -8 dBm SFP-100-LC-SM40: -5 to 0 dBm SFP-100-MTRJ-MM: -20 to -14 dBm
Input optical power (Receiver sensitivity)
SFP-100-LC-MM: -31 to -14 dBm SFP-100-LC-SM15: -31 to 0dBm SFP-100-LC-SM40: -34 to 0 dBm SFP-100-MTRJ-MM: -31 to -14 dBm
Connector type SFP · Connections supported 100BaseFX

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-P24
The OS6600-P24 is a stackable edge/workgroup switch offering 24 Power over Ethernet (PoE) 10/100 Ethernet ports. The OS6600-P24 can also be equipped with up to four Gigabit Ethernet ports for connec- tions to a high speed backbone or server.
The front panel of the OS6600-P24 chassis contains the following major components:

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-P24
Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.
Console Port The OS6600-P24 front panel provides one RJ- 45 port for console connections. Serial console connections are used by network administrators for switch management. This female RJ-45 con- nector provides a DCE console connection.
Gigabit Ethernet Uplink Module Slot The OS6600-P24 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:
CONSOLE
SEL
OK1
PS1
LINK/ACT LINK/ACT LINK/ACT LINK/ACT
OK2
PS2 PRI SEC TEMP FAN
Status and Slot Indicator LEDs For information on the OS6600-P24’s status and slot indicator LEDs, refer to page 2-18.
10/100 Ethernet Ports The OS6600-P24 provides 24 Power over Ethernet (PoE) 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors. For information more information, refer to page 2-18.
Stacking or Uplink Module Slot The OS6600-P24 provides an additional slot that can accommodate either a stacking mod- ule or a Gigabit Ethernet uplink module.
Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations.
If you use a Gigabit Ethernet uplink module in this slot, the OS6600-P24 must be used as a stand-alone switch.
A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
TM OmniSwitch 6600-P24

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-P24
Total number of PoE 10/100 Mbps ports per switch
Total number of Gigabit Ethernet ports per switch
4 (for stand-alone switches); 2 (for stacked configurations)
Total number of PoE 10/100 Mbps ports per stack
192 (stack of eight switches)
Total number of Gigabit Ethernet ports per stack
16 (stack of eight switches)
Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate
Current draw Switch functions (24 Volts max.): 2.3 Amps PoE (49 Volts max.): 4.3 Amps
Power Switch functions (24 Volts max.): 55 Watts (100 Watts available) PoE (49 Volts max.): 210 Watts
Total available power supplies (OS6600-P24)
Total available power supplies (OS6600-BPS-P)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
19.025 inches
Chassis Width (rack-mount flanges not included)
17.1 inches
Height 2.65 inches
Height (rack units) 1.5 RU
Chassis Depth 14.5 inches (without an OS6600-BPS-P) 19.3 inches (with an OS6600-BPS-P)
Chassis Weight Approximately 12 lbs
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6600-P24
Standards supported IEEE 802.3u, 802.3af (DTE Power via MDI MIB); IAB RFCs 826, 894
Data rate 10 or 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Connections supported 10BaseT or 100BaseTX IP phones, Bluetooth Access Points, Internet cameras, and other devices requiring power over Ethernet
Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm
Power supplied to port 15.4 watts per port
Maximum cable distance 100 meters
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6648
The OS6648 is a stackable edge/workgroup switch offering 48 10/100 Ethernet ports. The OS6648 can also be equipped with up to four Gigabit Ethernet ports for connections to a high speed backbone or server.
The front panel of the OS6648 chassis contains the following major components:
Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.
Console Port The OS6648 front panel provides one RS232 port for console connections. Serial console connections are used by network administrators for switch management. This female DB-9 con- nector provides a DCE console connection.
Gigabit Ethernet Uplink Module Slot The OS6648 provides a dedicated slot for Gigabit Ethernet uplink modules. This slot supports the following module types:
LINK/ACT LINK/ACT
EXPANSION/STACKING
49 50 51 52
OK1
PS1
PRI
TEMP
LINK/ACT LINK/ACT
OK2
PS2
SEC
FAN
SEL
Status and Slot Indicator LEDs For information on the OS6648’s status and slot indicator LEDs, refer to page 2-18.
10/100 Ethernet Ports The OS6648 provides 48 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.
Stacking or Uplink Module Slot The OS6648 provides an additional slot that can accommodate either a stacking module or a Gigabit Ethernet uplink module.
Slot Selector Button The slot selector button, located directly beneath the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed infor- mation.
If you use a Gigabit Ethernet uplink module in this slot, the OS6648 must be used as a stand-alone switch.
A stacking module must be installed in this slot if the switch is to be used in a stack. For detailed information on stacking switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
TM OmniSwitch 6648

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6648
Total number of 10/100 Mbps ports per switch
Total number of Gigabit Ether- net ports per switch
4 (for stand-alone switches); 2 (for stacked configurations)
Total number of 10/100 Mbps ports per stack
384 (stack of eight switches)
Total number of Gigabit Ether- net ports per stack
16 (stack of eight switches)
Fabric capacity 10.0 Gbps full duplex; 20.0 Gbps aggregate
Current draw Approximately 2.3 Amps
Power Approximately 55 Watts
Total power supplies 2 (one factory-installed power supply and one optional backup power supply)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
19.125 inches
Chassis Width (rack-mount flanges not included)
17.2 inches
Height 2.65 inches
Height (rack units) 1.5 RU
Chassis Depth 14 inches
Chassis Weight Approximately 14 lbs (15.5 lbs with optional backup power supply installed)
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)
Standards supported IEEE 802.3u, IAB RFCs 826, 894
Data rate 10 or 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Connections supported 10BaseT hub or device; 100BaseTX hub or device
Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm
Maximum cable distance 100 meters
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6602-24
The OS6602-24 is a stackable edge/workgroup switch offering 24 10/100 Ethernet ports. The OS6602-24 has Gigabit Ethernet ports for connections to a high speed backbone or server and two ports for stacking switches.
The front panel of the OS6602-24 chassis contains the following major components:
Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.
10/100 Ethernet Ports The OS6602-24 provides 24 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.
Console Port The OS6602-24 front panel pro- vides one serial port for console connections. Serial console con- nections are used by network administrators for switch man- agement. This female RJ-45 con- nector provides a DCE console connection.
Status and Slot Indicator LEDs For information on the OS6602-24’s status and slot indicator LEDs, refer to page 2-18.
Slot Selector Button The slot selector button, located to the right of the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed infor- mation.
3 1 2 4 5 6 7 9 8 10 12 11 13 1
17 16 15 14 21 19 18 20 22 23 24
C o n s o l e
PR1
TMP
OK2
PS2
SEC
FAN
CLASS 1 LASER PRODUCT
Gigabit Ethernet Uplink Ports The OS6602-24 provides two MiniGBIC Gigabit Ethernet slots. Refer to page 2-45 for information on MiniGBIC types.
Stacking Ports The OS6602-24 provides two built-in stacking ports. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed information on using these ports to stack switches in a stack.
TM OmniSwitch 6602-24 · Sel · Stack

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6602-24
Total number of 10/100 Mbps ports per switch
Total number of Gigabit Ethernet ports per switch
Total number of 10/100 Mbps ports per stack
192 (stack of eight switches)
Total number of Gigabit Ethernet ports per stack
16 (stack of eight switches)
Fabric capacity 7.0 Gbps full duplex; 14 Gbps aggregate
Current draw Approximately 0.3 Amps @ 115VAC
Power Approximately 34 Watts @ 25C
Total available power supplies 2 (one factory-installed power supply and one optional backup power supply)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
18.95 inches
Chassis Width (rack-mount flanges not included)
17.25 inches
Height 1.75 inches
Height (rack units) 1 RU
Chassis Depth 16.95 inches
Chassis Weight Approximately 11.9 lbs
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)
Standards supported IEEE 802.3u, IAB RFCs 826, 894
Data rate 10 or 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Connections supported 10BaseT hub or device; 100BaseTX hub or device
Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm
Maximum cable distance 100 meters
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6602-48
The OS6602-48 is a stackable edge/workgroup switch offering 48 10/100 Ethernet ports. The OS6602-48 has Gigabit Ethernet ports for connections to a high speed backbone or server and two ports for stacking switches.
The front panel of the OS6602-48 chassis contains the following major components:
Refer to the illustration below for more front panel information. For detailed LED descriptions, refer to page 2-18. For information on the chassis rear panel, refer to page 2-20.
10/100 Ethernet Ports The OS6602-48 provides 48 10/100 Ethernet ports. These ports are twisted-pair and are individually configurable as 10BaseT or 100BaseTX. The ports use RJ-45 connectors.
Console Port The OS6602-48 front panel pro- vides one serial port for console connections. Serial console con- nections are used by network administrators for switch man- agement. This female RJ-45 con- nector provides a DCE console connection.
Status and Slot Indicator LEDs For information on the OS6602-48’s status and slot indicator LEDs, refer to page 2-18.
Slot Selector Button The slot selector button, located to the right of the slot indicator LED, is used to manually assign slot numbers to switches in stacked configurations. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed infor- mation.
3 1 2 4 5 6 7 9 8 10 12 11 13 1
17 16 15 14 21 19 18 20 22 23 24
TM OmniSwitch 6602-48 25
26 28 29 30 31 33 32 34 36 35 37 41 40 39 38 45 43 42 44 46 47 48
C o n s o l e
PR1
TMP
OK2
PS2
SEC
FAN
CLASS 1 LASER PRODUCT
Gigabit Ethernet Uplink Ports The OS6602-48 provides two MiniGBIC Gigabit Ethernet slots. Refer to page 2-45 for information on MiniGBIC types.
Stacking Ports The OS6602-48 provides two built-in stacking ports. Refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks,” for detailed information on using these ports to stack switches in a stack.
Sel · Stack

OmniSwitch 6600 Family Chassis and Hardware Components OmniSwitch 6602-48
Total number of 10/100 Mbps ports per switch
Total number of Gigabit Ether- net ports per switch
Total number of 10/100 Mbps ports per stack
384 (stack of eight switches)
Total number of Gigabit Ether- net ports per stack
16 (stack of eight switches)
Fabric capacity 10.0 Gbps full duplex; 20.0 Gbps aggregate
Current draw Approximately 0.4 Amps @ 115VAC
Power Approximately 46 Watts @ 25C
Total power supplies 2 (one factory-installed power supply and one optional backup power supply)
Flash memory size 64 MB
RAM memory size 128 MB
Overall Width (rack-mount flanges included)
18.95 inches
Chassis Width (rack-mount flanges not included)
17.25 inches
Height 1.75 inches
Height (rack units) 1 RU
Chassis Depth 16.95 inches
Chassis Weight Approximately 12.0 lbs
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude Sea level to 10,000 feet (3 km)
Standards supported IEEE 802.3u, IAB RFCs 826, 894
Data rate 10 or 100 Mbps (full or half duplex)
Maximum frame size 1518 Bytes; 1522 Bytes with IEEE 802.1Q tags
Connections supported 10BaseT hub or device; 100BaseTX hub or device
Cable supported 10BaseT: unshielded twisted-pair (UTP) 100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 or shielded twisted-pair (STP), Category 5, 100 ohm
Maximum cable distance 100 meters
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components Status LEDs
LEDs provide visual status information. These “status lights” are used to indicate conditions such as hardware and software status, primary and backup power supply status, primary and secondary status (stacked configurations), temperature and fan errors, slot number information, link integrity, and data flow. Refer to the diagram below for detailed information on OmniSwitch 6600 Family LED states.
Ethernet Port LEDs Each Ethernet port has a built-in corresponding status LED on the lefthand side (OS6624, OS6648, OS6600-P24), below the port OS6600-U24), or above the port (OS6602- 24 and OS6602-48). This LED indicates the link and activ- ity status for each Ethernet port. The LED displays green when a valid Ethernet cable connection exists. Flashes green as data is transmitted or received on the port. The OS6600-P24 only has a right-hand PoE LED. This LED displays solid green when power is properly supplied to the port. Flashes green when there is an overload or short. And this LED is off if there is a power failure.
Slot Indicator LED The slot indicator LED is manually configurable and displays the switch’s current slot number in a stacked configuration (i.e., 1 – 8). For detailed information on manually setting the switch’s slot number, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
Port Power LED (OS6600-P24 only)
LINK/ACT LINK/ACT
EXPANSION/STACKING
49 50 51 52
OK1
PS1
PRI
TEMP
LINK/ACT LINK/ACT
OK2
PS2
SEC
FAN
SEL
Hardware and Software Status LEDs OK1. Hardware Status. Dis- plays solid green when pow- ered on and the switch has passed hardware diagnostic tests. Displays solid amber when powered on and the switch has failed hardware diagnostic tests.
Power Supply LEDs PS1. Displays solid green when the primary (i.e., factory- installed) power supply status is OK and the power supply is operating normally. Displays solid amber in the unlikely event of a power supply fail- ure.
Stack LEDs PRI. Displays solid green when if the switch is either a stand-alone switch or the pri- mary switch in a stack; other- wise, if the switch status is secondary or idle, this LED is off.
Temperature Management LEDs TEMP. Displays solid green when the switch is operating within the allowed temperature range; displays solid amber if a temperature error occurs (i.e., the switch is operating outside the temperature range).
SEC. Displays solid green if the switch is the secondary switch in a stack; otherwise, this LED is off.
PS2. Displays solid green when the optional redundant power supply status is OK and the power supply is operating normally. Displays solid amber if no redundant power supply is installed or in the unlikely event of a redundant power supply failure.
FAN. Displays solid green when all fans in the fan tray are running at normal speed. Displays solid amber if a fan error occurs (i.e., one or more fans are not running at normal speed).
OK2. Software Status. Blinks green when the switch’s sys- tem management software is operational. Displays solid amber when a system soft- ware failure occurs. Blinks amber when the software is in a transitional state (e.g., when software is being downloaded to the switch).
Status LED Location · TM OmniSwitch 6648

OmniSwitch 6600 Family Chassis and Hardware Components Status LEDs

OmniSwitch 6600 Family Chassis and Hardware Components Rear Panel
The rear panel of OmniSwitch 6600 Family switches contains the following major components:
indicates on position; indicates off position.
Ground Lug Connection Unpainted area for Type LCD copper lug attach- ment. Refer to page 2-25 for more information.
Product, Safety, and Compliance Information Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.
50/60 Hz, 2/2/1 A MODEL NO: OS-6648
100/115/230 V
RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
R R
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.
geprufte Sicherheit Assembled in the US of US and Non-US Components
Redundant Power Supply Bay Slot for optional user-installable OS6600-BPS (OS6624, OS6648, OS6600-U24) or OS6602-BPS (OS6602-24 and OS6602-48) backup power supply. For more information on the backup power supply, including technical specifications and installation instructions, refer to “Backup Power Supply” on page 2-26. Note: The OS6600-P24 does not have a backup power supply bay. Instead, it has a connector for the OS6600-BPS-P PoE backup power supply.
Power Connector Socket Type IEC-320-C13. Supports one 10 amp power cord.
PoE Power Connector Reserved for use with the PoE backup power supply on the OS6600-P24. See Chapter 3, “Installing and Managing Power over Ethernet (PoE).”
It is recommended that you use only Alcatel-provided power cords.
Power Switch · ! · TUV Rheinland ProductSafety

OmniSwitch 6600 Family Chassis and Hardware Components Mounting the Switch
Be sure that your switch is placed in a well-ventilated, static-free environment. Always allow adequate clearance at the front, rear, and sides of the switch.
The following diagram shows recommended minimum clearances for adequate chassis airflow and access to components at the rear of the chassis—e.g., backup power supply and power switch(es).
Rear Recommended 5 inches minimum at rear of chassis for access to power switch(es) and power cord(s).
Sides 2 inches minimum at left and right sides for adequate air- flow. For detailed information on chassis airflow, refer to page 2-58.
Front Recommended 6 inches minimum at front of chassis for access to LEDs and network cables. }

OmniSwitch 6600 Family Chassis and Hardware Components Mounting the Switch
There are two ways in which the OmniSwitch 6600 Family switches can be installed:
OmniSwitch 6600 Family switches can be installed freestanding as tabletop units. Place your switch in a stable, flat, static-free surface.
To install the switch as a tabletop unit, follow the steps below:
1 Position the chassis on the table or bench where it is to be installed.
2 Be sure that adequate clearance has been provided for chassis airflow and access to the front, back, and sides of the switch. For recommended clearances, refer to page 2-21. Also, be sure that you have placed the chassis within reach of all required AC power sources.
3 If you are placing multiple switches in a stacked configuration, carefully stack the remaining switches, one on top of the other. Up to eight switches may be stacked to form a single virtual chassis. Be sure to maintain adequate clearance at the front, rear, left, and right side of all switches. Also, be sure that you have placed all switches in the stack within reach of required AC power sources.
Refer to the important guidelines below before installing the OmniSwitch chassis in a rack.

OmniSwitch 6600 Family Chassis and Hardware Components Mounting the Switch
To rack-mount the switch, follow the steps below:
1 Align the holes in the provided rack-mount flanges with the four threaded holes in the OmniSwitch chassis. These threaded holes are located in the left and right sides of the chassis, near the front panel.
2 Attach the flanges to the chassis using the provided Phillips-head screws. Be sure to tighten each of the screws firmly using a Phillips screwdriver.

PRI
TEMP
SEL
PS1
FAN
OK1
SEC
OK2
PS2
Attaching a Rack-Mount Flange
3 After the rack-mount flanges are secured to the chassis, mark the holes on the rack where the switch is to be installed.
4 Lift and position the switch until the rack-mount flanges are flush with the rack post.
5 Align the holes in the flanges with the rack holes that were marked in step 3.
6 Once the holes are aligned, insert a rack mount screw (not provided) through the bottom hole of each flange. Tighten both screws until they are secure.
EXPANSION 49 50 5 1 5 2
Attaching the Switch to the Rack
TM OmniSwitch 6624

OmniSwitch 6600 Family Chassis and Hardware Components Mounting the Switch
7 Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws. Be sure that all screws are securely tightened.
If you are rack mounting multiple switches in a stacked configuration, be sure to place all switches in vertically-adjacent rack positions. This will ensure that all required stacking cables will have adequate length for the installation. For additional instructions on rack mounting a stacked configuration, follow the steps below:
1 Install the rack mount flanges for all switches that are to be included in the stacked configuration, as described on page 2-23. Up to eight switches may be stacked to form a single virtual chassis.
2 Place the next switch in the stack directly on top of the previously installed switch.
3 Align the holes in the flanges with the holes in the rack’s vertical posts.
4 Once the holes are aligned, insert a rack mount screw through the bottom hole of each flange. Tighten both screws until they are secure. Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws. Be sure that all screws are securely tightened.
5 Repeat steps 1 through 4 above for all remaining switches.

OmniSwitch 6600 Family Chassis and Hardware Components Power Cords
Since the power cord is the power supply’s main disconnect device, it should be plugged into an easily accessible outlet. In the event that your power cord is lost or damaged, refer to the specifications below.
The power cord to be used with 115-Volt configuration is a minimum type SJT (SVT) 18/3, rated at 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates in a NEMA 5-15P plug.
The power cord to be used with 230-Volt configuration is minimum type SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates as required by the country where it will be installed.
European cords must be Harmonized (HAR) type. Refer to the information below for power plug types by region:
North America NEMA 5-15-P (US), C22.2, No. 42 (Canada)
United Kingdom / Ireland BS 1,363
Switzerland / Liechtenstein SEV 1011
Denmark / Greenland SRAF 1,962 / D816 / 87
The switch has two threaded holes for grounding screws located on the back of the chassis. These holes use 10-32 screws and are approximately one inch apart. These holes are surrounded by a small paint-free rectangular area, which provides metal-to-metal contact for a ground connection.
Use this connector to supplement the ground provided by the AC power cord. To do so, install a Panduit Grounding Lug (type LCD8-10A-L) using 8AWG copper conductors to the paint-free rectangular area. Be sure to use a crimping tool.

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
OmniSwitch 6600 Family switches provide one factory-installed power supply per chassis. OmniSwitch 6624, 6600-U24, and 6648 switches provide one bay for the optional OS6600-BPS backup power supply while OmniSwitch 6602-24 and 6602-48 switches provide one bay for the optional OS6602-BPS or OS6602-BPS-DC backup power supplies. This backup power supply bay is located on the chassis rear panel (see page 2-20 for details).
Power Connector Socket. Type IEC-320-C13 (OS6600-BPS and OS6602-BPS). Supports one 10 amp power cord.
Product, Safety, and Compliance Information. Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.
It is recommended that you use Alcatel- provided power cords.
50/60 Hz, 2/2/1 A 100/115/230 V
Power Switch.
indicates on position; indicates off position.
OmniSwitch 6600-P24 switches use the external OS6600-BPS-P backup power supply, which provides backup electrical current used for switch functions and PoE ports. The OS6600-BPS-P contains two built- in power supplies—one supplying 55 Watts (100 Watts maximum) for switch functions and the other supplying 210 watts for PoE functions. For information on setting up the OS6600-BPS-P, refer to Chapter 3, “Installing and Managing Power over Ethernet (PoE).”

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
OS6600-P24 Connectors Two attachment locations on each side of the BPS to connect to the OS6600-P24.
BPS Power Connector Reserved for use with the OS6600-BPS backup power supply on the OS6600-P24.
Assembled in the US of US and Non-US Components
O I
CET APPAREIL NUMERIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU REGLEMENT SUR LE MATERIEL BROUILLEUR DU CANADA.
S
THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS. THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
I.T.E.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
TUV
RATING: MODEL NO:
100/115/220/230 V , 50/60 Hz, 2/2/1/1 A
U.S. PATENT NO. 5,394,402
6600-BPS-P
OS6600-BPS-P Backup Power Supply Back Panel

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
OS6602-BPS-DC Backup Power Supply Back Panel
For information on installing a backup power supply, refer to page 2-31. For information on removing a backup power supply, refer to page 2-33.
The tables below list the specifications for OmniSwitch 6600 Family backup power supplies:
Input Voltage 85 to 250 VAC
Input Frequency 47 to 63 Hz
Efficiency 75% measured at 115 VAC
Relative Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude 10,000 feet @ +32 Celsius

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
Input Voltage 85 to 150 VAC
Input Frequency 47 to 63 Hz
Efficiency 75% measured at 115 VAC
Relative Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude 10,000 feet @ +32 Celsius
Input Voltage 36 to 72 VAC
Efficiency 75% measured at 115 VAC
Relative Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude 10,000 feet @ +32 Celsius
Width 15.50 inches, approx.
Height 2.61 inches, approx.
Height (rack units) 1.5 RU
Depth 4.53 inches, approx.
Ambient Temperature 0 to +70 deg C, operating; -40 to +85 deg C, non-operating
Humidity 5% to 90% Relative Humidity (Operating) 0% to 95% Relative Humidity (Storage)
Altitude 10000 feet at +32 deg C, operating; 50000 feet, non-operating
After a backup power supply is installed, the primary (factory-installed) power supply continues to take on the full power load for switch operations. Meanwhile, the backup power supply operates in active standby mode. If the primary power supply fails unexpectedly, the backup power supply automatically takes up the full power load without disrupting the switch.
Input Frequency N/A

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
When a backup power supply is installed, it is recommended that the AC source connected to the backup power supply resides on a separate circuit from the primary power supply. With redundant AC, if a single circuit fails, the switch’s backup power supply (on a separate circuit) will likely be unaffected and the switch can continue operating.
The diagram below shows a simple redundant AC circuit scenario for OS6600 Family switches.
Factory-Installed (Primary) Power Supply
Both the primary and redundant power supplies are installed in the chassis, providing power supply redundancy.
LISTED I.T.E. 5Z71 E164613C !
50/60 Hz, 2/2/1 A MODEL NO: OS-6648
RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
50/60 Hz, 2/2/1 A 100/115/230 V
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.
geprufte Sicherheit Assembled in the US of US and Non-US Components
Each power supply is connected to an AC source on a separate circuit.
Factory-Installed (Primary) Power Supply In the event of a failure at circuit 1 (for example, a tripped circuit breaker), the redundant power supply plugged into the grounded AC outlet on circuit 2 allows switch operations to continue.
50/60 Hz, 2/2/1 A MODEL NO: OS-6648
RATING: 100-240V 50-60Hz, 1.02A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
100/115/230 V
50/60 Hz, 2/2/1 A 100/115/230 V
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.
geprufte Sicherheit Assembled in the US of US and Non-US Components

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
You can add a backup power supply to the chassis at any time without disturbing the switch’s network functions. You are not required to power down the switch.
Hot swapping a backup power supply refers to the action of replacing the unit while the switch is operat- ing. Again, because it is a backup (i.e., redundant component), you are not required to power off the switch’s primary power source.
To add the optional backup power supply to the chassis, follow the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the backup power supply.
1 Locate the backup power supply bay. The backup power supply bay is located at the switch’s rear panel. Refer to page 2-20 for a view of the chassis rear panel.
2 If there is a blank cover panel installed at the backup power supply bay, uninstall it by removing the two Phillips attachment screws. After the attachment screws have been removed, carefully pry the blank cover panel out and away from the chassis. Set the cover panel and attachment screws aside.
3 To avoid attempting to install the backup power supply upside down, orient the unit as shown in the diagram below.
50/60 Hz, 2/2/1 A 100/115/230 V
Orient the backup power supply with the vent side up, as shown.
Top · !

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
4 Grasp the front portion of the power supply and carefully insert the rear of the casing into the power supply bay. Slide the power supply back until the unit meets the connector in the chassis power supply bay.
Assembled in the US of US and Non-US Components

50/60 Hz, 2/2/1 A 100/115/230 V
50/60 Hz, 2/2/1 A 100/115/230 V
geprufte Sicherheit Assembled in the US of US and Non-US Components
LISTED I.T.E. 5Z71 E164613C
ÉRIEL BROUILLEUR DU CANADA.
50/60 Hz, 2/2/1 A 100/115/230 V
5 Continue sliding the power supply back until the front panel is flush with the rear panel of the chassis. Do not force the power supply into the bay. Otherwise you can damage the connectors.
6 Tighten the two captive screws, located at the left and right sides of the power supply’s front panel. Be sure not to overtighten the captive screws. If you use a screwdriver, the torque used to tighten the screws must not exceed 2.3 inch pounds.
Assembled in the US of US and Non-US Components !
MODEL NO: OS RATING: 100-240V THIS DEVICE COMPLIES WITH IS SUBJECT TO THE FOLLOWING T (1) THIS DEVICE MAY NOT CAUSE HAR (2) THIS DEVICE MUST ACCEPT ANY INTER INTERFERENCE THAT MAY CAUSE UNDESIRED
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIRE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULAT
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA
50/60 Hz, 2/2/1 A 100/115/230 V
7 Verify that the power supply’s on/off switch is in the off ( O ) position.
8 Connect the power supply cord (provided) into an easily accessible power source.

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
1 Before removing the backup power supply, make sure that the power switch is in the off ( O ) position.
2 Unplug the power cord from the AC power source, as well as from the socket located on the power supply’s front panel.
3 Loosen the two captive screws, located at the left and right sides of the power supply’s front panel. If necessary, use a flat-blade screwdriver to loosen the screws.
MODEL NO: OS RATING: 100-240V THIS DEVICE COMPLIES WITH IS SUBJECT TO THE FOLLOWING T (1) THIS DEVICE MAY NOT CAUSE HAR (2) THIS DEVICE MUST ACCEPT ANY INTER INTERFERENCE THAT MAY CAUSE UNDESIRED
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA
Assembled in the US of US and Non-US Components !
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIRE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULAT
50/60 Hz, 2/2/1 A 100/115/230 V
4 Once the captive screws are completely disengaged, grasp both captive screws and slowly pull the power supply out of the power supply bay.
Assembled in the US of US and Non-US Components

50/60 Hz, 2/2/1 A 100/115/230 V
50/60 Hz, 2/2/1 A 100/115/230 V
R R
LISTED I.T.E. 5Z71 E164613C
geprufte Sicherheit Assembled in the US of US and Non-US Components
ÉRIEL BROUILLEUR DU CANADA.
50/60 Hz, 2/2/1 A 100/115/230 V
5 Store the power supply in a secure, static-free location. Placing the unit in an anti-static bag is recommended.

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
If you are not replacing the backup power supply being removed, be sure to install a blank cover panel (supplied with your switch) over the empty power supply bay. To install a blank cover panel, follow the steps below.
1 Place the blank cover panel over the empty power supply bay and insert two Phillips screws (also supplied with the switch) through the panel and into the threaded holes in the chassis.
2 Once the screws are inserted, fasten the panel to the chassis by tightening the screws. Be sure not to overtighten the screws.
The switch constantly monitors primary and backup power supply operation. If either power supply unex- pectedly shuts down, the switch sends out a trap to the user and the PS1 and/or PS2 LEDs on the chassis front panel turn amber.
To check the number of power supplies currently operating, and the status of each power supply, use the show power command. For example:
-> show power Power Supplies in chassis 8 PS Operational Status + PS-1 UP PS-2 NOT PRESENT
The primary (i.e., factory-installed) power supply is listed as PS-1 in the show power command output. The backup power supply is listed as PS-2. In the example above, there is no backup power supply installed in the chassis.

OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
When entering the show power command on the primary switch in a stacked configuration, you can either enter only the show power syntax or you can specify a specific slot number. For more information, refer to the examples below:
If you specify a slot number after the command syntax, power supply information for only the correspond- ing switch displays. For example:
-> show power 2 Power Supplies in chassis 2 PS Operational Status + PS-1 UP PS-2 NOT PRESENT
In the example above, power supply status for the switch operating in slot 2 displays. No backup power supply is installed in the slot 2 chassis (or the backup power supply is powered off).
If you do not enter a slot number, power supply information for all switches in the stack displays. For example:
-> show power Power Supplies in chassis 1 PS Operational Status + PS-1 UP PS-2 UP
Power Supplies in chassis 2 PS Operational Status + PS-1 UP PS-2 NOT PRESENT
The example above shows the power supply status for a stack consisting of two switches. A backup power supply is present and running in the switch operating in slot 1; no backup power supply is installed in the switch operating in slot 2 (or the unit is powered off).
More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”

OmniSwitch 6600 Family Chassis and Hardware Components Gigabit Ethernet Uplink Modules
OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches support the following Gigabit Ethernet uplink modules:
The OS6600-GNI-U2 Gigabit Ethernet uplink module provides two MiniGBIC bays that support 1000BASE-X MiniGBIC transceivers. Cable options include multimode, single mode, and long-reach single mode fiber. The OS6600-GNI-U2 supports bi-directional wire speed switching on all ports simulta- neously. Also, because it supports any combination of the three MiniGBIC options, this module offers a flexible solution for various customer requirements.
This uplink module may be used to support multiple uplinks from the wiring closet switch to the Gigabit Ethernet backbone links in the core. With the two MiniGBIC ports provided by the OS6600-GNI-U2, upto 16 Gigabit Ethernet ports can be supported in a fully-loaded stacked configuration.
MiniGBIC Slots The OS6600-GNI-U2 provides two universal MiniGBIC ports for hot-pluggable MiniGBIC fiber transceivers. MiniGBIC options include multimode, single mode, and long-reach single mode fiber. Refer to “Mini Gigabit Inter- face Converters (MiniGBICs)” on page 2-44 for more infor- mation.
LINK/ACT LEDs Each MiniGBIC port has a built-in corresponding LED. This LED indicates the link and activity status for each MiniGBIC installed. The LED displays green when a valid cable connection exists. Flashes green as data is transmitted or received on the interface.

OmniSwitch 6600 Family Chassis and Hardware Components Gigabit Ethernet Uplink Modules
Number of ports 2 (hot-pluggable)
Power Approximately 5 Watts
Standards supported 802.3z; 1000Base-SX, 1000Base-LX
Data rate 1 Gigabit per second (full duplex)
Connector type MiniGBIC

OmniSwitch 6600 Family Chassis and Hardware Components Gigabit Ethernet Uplink Modules
The OS6600-GNI-C2 Gigabit Ethernet uplink module provides two fixed 1000BASE-T (copper) connec- tions. This uplink module supports bi-directional wire speed switching on all ports simultaneously and offers a flexible solution for Gigabit Ethernet-over-copper applications.
The OS6600-GNI-C2 uplink module supports multiple uplinks from the wiring closet to Gigabit Ethernet backbone links in the core. With the two RJ-45 ports on this uplink module, upto 16 Gigabit Ethernet ports can be supported in a fully loaded stackable configuration.
Copper Gigabit Ethernet Ports TheOS6600-GNI-C2 provides two fixed 1000BASE-T (copper) connections. The port type is RJ-45.
LINK/ACT LEDs Each RJ-45 port has a built-in corresponding LED. This LED indi- cates the link and activity status for each Gigabit Ethernet copper port. The LED displays green when a valid cable connection exists. Flashes green as data is transmitted or received on the interface.
OS6600-GNI-C2 Uplink Module Specifications
Number of ports 2 twisted-pair
Power Approximately 9 Watts
Standards supported 802.3z, 802.3ab; 1000Base-T
Data rate 1 Gigabit per second (full duplex)
Connections supported 1000BaseT connection to backbone or server
Cable supported 1000BaseT unshielded twisted-pair (UTP), Category 5e
Maximum cable distance 100 meters, Category 5
Connector type RJ-45

OmniSwitch 6600 Family Chassis and Hardware Components Gigabit Ethernet Uplink Modules
Stacking modules are used to connect OmniSwitch 6624, 6600-U24, and 6648 switches in a stack. (OmniSwitch 6602-24 and 6602-48 switches have built-in stacking ports.) The stack acts as a virtual chas- sis, with switches serving as primary and secondary management modules and Network Interface (NI) modules. For detailed information, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
For information on installing stacking modules, refer to page 2-40. For information on removing stacking modules, refer to page 2-42. For important installation restrictions, refer to the chassis front panel informa- tion on pages 2-2 and 2-12, as well as “Installing Uplink and Stacking Modules” on page 2-40.
HSSDC Stacking Connectors The stacking module provides two dedicated High Speed Serial Data Connectors (HSSDCs). These connectors are used to connect OS6624/ OS6600-U24/OS6648 switches in a stack. For detailed information on stacks, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
LINK/ACT LEDs Each stacking connector has a built-in corresponding LED. This LED indicates the link and activity status for each connector. The LED dis- plays green when a valid cable connection exists. Flashes green as data is being transmitted to, or received from, the adjacent switch in the stack.
Stacking Module Specifications
Number of ports 2
Power Approximately 8 Watts
Data Speed 1 Gigabit per second per stacking cable installed
Connector type High Speed Serial Data Connector (HSSDC)
Chassis port locations 27 and 28 (OS6624, OS6600-U24, and OS6600- P24); 51 and 52 (OS6648)
Hot-swappable with other module types? No

OmniSwitch 6600 Family Chassis and Hardware Components Installing Uplink and Stacking Modules
Before installing uplink or stacking modules, refer to the important guidelines listed below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the uplink or stack- ing module.
1 If there is a blank cover panel installed over the uplink or stacking module slot position, uninstall it by removing the two Phillips attachment screws. After the attachment screws have been removed, carefully pry the blank cover panel out and away from the chassis. Set the cover panel and attachment screws aside.
2 Holding the uplink or stacking module by the front panel, carefully slide the circuit board into the card guide located in the chassis slot.
5 1 5 2
Inserting the Uplink or Stacking Module

OmniSwitch 6600 Family Chassis and Hardware Components Installing Uplink and Stacking Modules
3 Slide the module back until the backplane connector is inserted in the chassis backplane; the module’s front panel should be flush with the front of the chassis. Do not force the module into the slot. Otherwise you can damage the connectors.
4 Once the module is firmly seated and flush with the chassis front panel, secure the module by tighten- ing the two captive screws. Be sure not to overtighten the captive screws. If you use a screwdriver, the torque used to tighten the screws must not exceed 2.3 inch pounds.
5 1 5 2
Tightening the Captive Screws

OmniSwitch 6600 Family Chassis and Hardware Components Removing Uplink and Stacking Modules
To remove an uplink or stacking module from the chassis, follow the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the uplink or stack- ing module.
1 Loosen the two captive screws, located at the left and right sides of the module’s front panel. If neces- sary, use a Phillips screwdriver to loosen the screws.
5 1 5 2
Loosening the Captive Screws

OmniSwitch 6600 Family Chassis and Hardware Components Removing Uplink and Stacking Modules
2 Once the captive screws are completely disengaged, grasp both captive screws and slowly pull the module out of the slot.
5 1 5 2
EXPANSION 49 50 5 1 5 2
EXPANSION/STACKING
LINK/ACT LINK/ACT
CONSOLE
OK1
PS1
PS2
PRI
SEC
TEMP
FAN
SEL
OK2
Removing the Module
3 Store the module in a secure, static-free location. Placing the module in an anti-static bag is recom- mended.
If you are not replacing the uplink or stacking module being removed, be sure to install a blank cover panel (supplied with your switch) over the empty module slot. To install a blank cover panel, follow the steps below.
1 Place the blank cover panel over the empty slot and insert two Phillips screws (also supplied with the switch) through the panel and into the threaded holes in the chassis.
2 Once the screws are inserted, fasten the panel to the chassis by tightening the screws. Be sure not to overtighten the screws.
TM OmniSwitch 6624

OmniSwitch 6600 Family Chassis and Hardware Components Mini Gigabit Interface Converters (MiniGBICs)
Mini Gigabit Interface Converters (MiniGBICs) are fiber-based Gigabit Ethernet transceivers for use with OS6600-GNI-U2 uplink modules on OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches and the built-in MiniGBIC ports on OmniSwitch 6602-24 and 6602-48 switches. MiniGBICs are interchangeable and hot-swappable, thus providing users an easy, flexible solution for adapting OS6600 Family switches to different physical interfaces types.
Alcatel offers three MiniGBIC options:
All MiniGBIC types support bi-directional wire-speed switching. For additional technical specifications on all three MiniGBIC types, refer to page 2-45. For information on installing MiniGBICs, refer to page 2-46.
Mini Gigabit Interface Converter (MiniGBIC)

OmniSwitch 6600 Family Chassis and Hardware Components Mini Gigabit Interface Converters (MiniGBICs)
Standards supported 802.3z, 1000Base-SX
Connections supported 1000Base-SX connection to backbone or server
Fiber optic cable supported Multimode
Source type 850 nm
Output optical power -9.5 to 0 dBm
Input optical power -17 to 0 dBm
Cable distance ≈ 220 m
Standards supported 802.3z, 1000Base-LX
Connections supported 1000Base-LX connection to backbone or server
Fiber optic cable supported Single mode
Source type 1310 nm
Output optical power -11 to -3 dBm
Input optical power -19 to -3 dBm (intermediate reach single mode)
Cable distance ≈10 km
Standards supported 802.3z, 1000Base-LH70
Connections supported 1000Base-LH70 connection to backbone or server
Fiber optic cable supported Single mode
Source type 1550 nm
Output optical power 0 to +5 dBm
Input optical power -23 to -3 dBm
Cable distance Long reach single mode fiber ≈ 70 km (up to 100 km using premium single mode fiber or dispersion-shifted single mode fiber)
Connector type LC · Connector types LC · Connector types LC

OmniSwitch 6600 Family Chassis and Hardware Components Installing MiniGBICs
Each OS6600-GNI-U2 uplink module supports up to two MiniGBICs on OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches. On OmniSwitch 6602-24 and 6602-48 there are two built-in MiniGBIC ports for MiniGBICs. These MiniGBICs are packaged separately and therefore are not factory-installed. You can install the MiniGBIC(s) by following the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the MiniGBIC, as well as the switch and uplink module.
1 Holding the MiniGBIC by its sides, carefully slide it into the desired MiniGBIC slot in the OS6600- GNI-U2 module on OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches or the built-in MiniG- BIC ports on OmniSwitch 6602-24 and 6602-48 switches, as shown.
5 1 5 2
EXPANSION/STACKING
CONSOLE
OK1
PS1
PRI
SEC
TEMP
FAN
SEL
OK2
PS2
Inserting the MiniGBIC (OS6648 Shown)
TM OmniSwitch 6624

OmniSwitch 6600 Family Chassis and Hardware Components Removing MiniGBICs
2 Push the MiniGBIC into the slot until it is completely inserted and securely seated in the OS6600-GNI-U2 module on OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 or the built-in MiniGBIC ports on OmniSwitch 6602-24 and 6602-48 switches, as shown.
5 1 5 2
Removing MiniGBICs
MiniGBICs modules can be hot swapped. You are not required to power off the switch before removing a MiniGBIC from the uplink module. To remove a MiniGBIC from the uplink module, follow the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the MiniGBIC, as well as the switch and uplink module.
1 On OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches only, make sure that the captive screws on the OS6600-GNI-U2 are tightened and the module is securely installed in the chassis.
2 There is a small removal handle at the front of the MiniGBIC transceiver. Carefully lift this handle; then, grasp the handle and carefully pull the MiniGBIC from the module.
3 Store the MiniGBIC in a secure, static-free location. Placing the MiniGBIC in an anti-static bag is recommended.

OmniSwitch 6600 Family Chassis and Hardware Components 100 Mbps SFPs (OS6600-U24)
Small Form Pluggable (SFP) modules are fiber-based 100 Mbps Ethernet transceivers for use with ports 1 through 24 on OmniSwitch 6600-U24. SFPs are interchangeable and hot-swappable, thus providing users an easy, flexible solution for adapting OS6600-U24 switches to different physical interfaces types.
Alcatel offers four SFP options:
All SFP types support bi-directional wire-speed switching. For additional technical specifications on all four SFP types, refer to page 2-49. For information on installing SFPs, refer to page 2-51.

OmniSwitch 6600 Family Chassis and Hardware Components 100 Mbps SFPs (OS6600-U24)
Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)
Fiber optic cable supported multimode fiber
Source type 62.5/125 and 50/125 micron
Output optical power -19 to -14 dBm (62.5/125); -22.5 to -14 dBm (50/125)
Input optical power (Receiver sensitivity)
-31 to -14 dBm
Cable distance 2 km
Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)
Fiber optic cable supported single mode fiber
Source type 9/125 micron
Output optical power -15 to -8 dBm
Input optical power (Receiver sensitivity)
-31 to 0 dBm
Cable distance 15 km
Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)
Fiber optic cable supported single mode fiber
Source type 9/125 micron
Output optical power -5 to 0 dBm
Input optical power (Receiver sensitivity)
-34 to 0 dBm
Cable distance 40 km

OmniSwitch 6600 Family Chassis and Hardware Components 100 Mbps SFPs (OS6600-U24)
Standards supported IEEE 802.3u, IAB RFCs 826, 894 (see data sheet for more information)
Fiber optic cable supported multimode fiber
Source type 62.5/125 and 50/125 micron
Output optical power -20 to -14 dBm (multimode)
Input optical power (Receiver sensitivity)
-31 to -14 dBm
Cable distance 2 km
Connector types MTRJ · Connections supported 100BaseFM

OmniSwitch 6600 Family Chassis and Hardware Components Installing SFPs (OS6600-U24)
OmniSwitch 6600-U24 switches support upto twenty-four 100 Mbps Small Form Pluggable (SFP) modules. These SFPs are packaged separately and therefore are not factory-installed. You can install the SFP(s) by following the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the SFP, as well as the switch and uplink module.
1 Align the transceiver with the transceiver slot on the OS6600-U24 as shown.
2 Holding the SFP by its sides, carefully slide it into the desired SFP slot (ports 1–24) until it clicks into place; this is an indication that the connectors are firmly seated.

OmniSwitch 6600 Family Chassis and Hardware Components Removing SFPs (OS6600-U24)
SFPs modules can be hot swapped. You are not required to power off the switch before removing a SFP from the uplink module. To remove a SFP from the uplink module, follow the steps below:
Anti-Static Warning. Before handling any component, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the SFP, as well as the switch and uplink module.
1 On some SFPs there is a small removal handle at the front of the SFP transceiver. Carefully lift this handle.
On other SFPs there is an ejector button located just below the transceiver port. Push this button to disengage the SFP.
2 Grasp the SFP and carefully pull it from the OS6600-U24.
3 Store the SFP in a secure, static-free location. Placing the SFP in an anti-static bag is recommended.

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
The operating temperature of your switch is an important factor in its overall health. In order to avoid a temperature-related system failure, your switch must always run at an operating temperature between 0 and 45 degrees Celsius (32 to 113 degrees Fahrenheit).
To avoid chassis over-temperature conditions, follow these important guidelines:
1 Be sure that your switch is installed in a well-ventilated environment. To ensure adequate airflow, leave at least two inches of clearance at the left and right sides.
2 If your switch chassis is not fully populated with uplink or stacking modules, be sure that blank cover panels are installed at empty slot positions at all times. Blank cover panels help regulate airflow and thus regulate the overall operating temperature in the switch. Refer to page 2-59 for more information.
As with power supply status, the switch constantly monitors the chassis temperature. If a temperature error has occurred, the switch sends out a trap to the user and the TEMP LED on the chassis front panel displays amber.
To check the current chassis temperature status, use the show temperature command. For example:
Temperature for chassis 1 Hardware Board Temperature (deg C) = 39, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77
In the example above, the switch’s current temperature is 39 degrees Celsius. The switch is operating under the upper temperature threshold, which is 57 degrees Celsius.
-> show temperature

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
When entering the show temperature command on the primary switch in a stacked configuration, you can either enter only the show temperature syntax or you can specify a specific slot number. For more information, refer to the examples below:
If you specify a slot number after the command syntax, chassis temperature information for only the corre- sponding switch displays. For example:
-> show temperature 3
Temperature for chassis 3 Hardware Board Temperature (deg C) = 43, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77
The example above shows chassis temperature information for the switch operating in slot position 3 only. The current temperature is 43 degrees Celsius. The switch is operating under the upper temperature thresh- old.
If you do not enter a slot number, fan status information for all switches in the stack displays. For example:
Temperature for chassis 1 Hardware Board Temperature (deg C) = 40, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77
Temperature for chassis 2 Hardware Board Temperature (deg C) = 31, Hardware Cpu Temperature (deg C) = N/A, Temperature Upper Threshold Range (deg C) = 30 to 77, Temperature Upper Threshold (deg C) = 57, Temperature Range = UNDER THRESHOLD, Temperature Danger Threshold (deg C) = 77
The example above shows chassis temperature information for a stack consisting of two switches. The current temperature of the switch operating in slot position 1 is 40 degrees Celsius; the current tempera- ture of the switch operating in slot 2 is 31 degrees Celsius. Both switches are operating under the upper temperature threshold.
More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
-> show temperature

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
The switch monitors the chassis ambient air temperature at all times via an onboard sensor. If an over- temperature condition occurs, there are two different levels of error severity:
If the temperature exceeds the switch’s user-configurable warning threshold, the switch sends out a trap. Traps are printed to the console in the form of text error messages. The chassis TEMP LED also displays amber, indicating an error. (Refer to page 2-18 for status LED locations and descriptions.)
When the warning threshold has been exceeded, switch operations remain active. However, it is recom- mended that immediate steps be taken to address the over-temperature condition.
Addressing warning threshold temperature conditions may include:
If the chassis ambient air temperature rises above the switch’s danger threshold of 80 degrees Centigrade, the switch will power off. The danger threshold is factory-set and cannot be configured by the user.
Addressing danger threshold temperature conditions may include:

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
The switch also constantly monitors fan operation. If any of the three fans unexpectedly shuts down, the switch sends out a trap to the user and the FAN LED on the chassis front panel displays amber.
To check the current fan status, use the show fan command. For example:
-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running
In the example above, all three fans are operating normally.
When entering the show fan command on the primary switch in a stacked configuration, you can either enter only the show fan syntax or you can specify a specific slot number. For more information, refer to the examples below:
If you specify a slot number after the command syntax, fan status information for only the corresponding switch displays. For example:
-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running
In the example above, fan status displays only for the switch operating in slot 3.

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
If you do not enter a slot number, fan status information for all switches in the stack displays. For example:
-> show fan Chassis Fan Status +---+ 1 1 Running 1 2 Running 1 3 Running 2 1 Running 2 2 Running 2 3 Running 3 1 Running 3 2 Running 3 3 Running
The example above shows the fan status for a stack consisting of three switches. All fans for those switches—operating in slots 1, 2, and 3—are operating normally.
More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
The fans pull air from the air intake vent located at the right-hand side of the chassis. The air is directed horizontally through the chassis and past the circuit board and uplink and stacking modules (if installed). Airflow is then exhausted through the fan vents at the left-hand side of the chassis. Refer to the illustra- tions below for more information.
Uplink and Stacking Submodules
Uplink and Stacking Submodules

OmniSwitch 6600 Family Chassis and Hardware Components Temperature Management
Blank cover panels are provided with your switch and are used to cover empty uplink and stacking module slots, as well as empty backup power supply bays (if applicable). These cover panels play an important role in chassis airflow and temperature management. They also protect the switch’s processor board and other sensitive internal switch components from physical damage by closing off a chassis that is not fully populated.
If your switch is not fully populated with submodules and a redundant power supply, and blank cover panels are not installed over empty slot locations, airflow is adversely affected.
When blank cover panels are missing, air does not take the direct route from the air intake vent, through the chassis, and then out through the fan exhaust vents. Instead, a portion of the airflow is allowed to be drawn in through the front and rear of the chassis. As a result, normal airflow is disrupted and an extra task is placed on the fans to cool the chassis.
Cover panels also provide protection for module processor boards and other sensitive internal switch components by closing off a chassis that is not fully populated.
Because they regulate airflow and help protect internal chassis components, blank cover panels should remain installed over empty module slots and power supply bays at all times.
Missing Cover Panels. Missing cover panels affect airflow by allowing air to be drawn in through the front submodule bays or rear redundant power supply bay. As a result, the direct route from the air intake vent to the fan exhaust vents is dis- rupted.
Air leakage due to missing redundant power supply panel
For optimal airflow and chassis component protec- tion, always install blank cover panels over empty slots and power supply bays.
Air leakage due to missing submodule cover panels
Air Intake Vent

OmniSwitch 6600 Family Chassis and Hardware Components Pinouts
Pin Number Description
1 RX+
2 RX-
3 TX+
6 TX-
Copper Gigabit Ethernet Port – RJ-45 Pinout
Pin Number Description
1 BI_DB+
2 BI_DB-
3 BI_DA+
4 BI_DD+
5 BI_DD-
6 BI_DA-
7 BI_DC+
8 BI_DC-
10/100 Mbps Power over Ethernet Port – RJ-45 Pinout (OS6600-P24)
Pin Number Description
1 RX+ (-VDC)
2 RX- (-VDC)
3 TX+ (+VDC)
6 TX- (+VDC)

OmniSwitch 6600 Family Chassis and Hardware Components Pinouts
Pin Number Signals as DCE Console Port
2 RXD (from the switch)
3 TXD (to the switch)
Pin Number Signals as DCE Console Port
1 CTS
2 NC
3 RXD
6 TXD
7 NC
8 RTS (Request To Send)

OmniSwitch 6600 Family Chassis and Hardware Components Console Port
The console port, located on the chassis front panel, provides a serial connection to the switch and is required when logging into the switch for the first time (refer to the OmniSwitch 6600 Family Getting Started Guide for more information). By default, this connector (a female DB-9 on OmniSwitch 6624 and 6648 switches and an RJ-45 port on OmniSwitch 6600-U24, 6600-P24, 6602-24, and 6602-48 switches) provides a DCE console connection.
The factory default settings for the serial connection are as follows:
data bits (word size) 8
If you wish to modify the default serial connection settings (i.e., baud rate, parity, data bits, and stop bits), refer to the following steps.
Note. You must be connected to the switch via the console port before attempting to change serial connec- tion settings. Otherwise, an error message will display. In addition, if you are changing console port settings for switches in a stack, console port settings must be identical on all switches. Before configuring the console port settings for a stack, make sure each switch is operating in either primary or secondary status (you may be required to disconnect switches within the stack before beginning).
1 Enter modify boot parameters at the CLI prompt. The boot prompt displays:
2 To change the baud rate, enter boot serialbaudrate, followed by the desired baud rate value. Options include 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 76800, and 115200. For example:
Boot > boot serialbaudrate 19200
3 To change the parity value, enter boot serialparity, followed by the desired parity value. Options include none (default), even, and odd. For example:
Boot > boot serialparity even

OmniSwitch 6600 Family Chassis and Hardware Components Console Port
4 To change the data bits (i.e., word size) value, enter boot serialwordsize, followed by the number of data bits. Options include 7 and 8 (default). For example:
Boot > boot serialwordsize 7
5 To change the stop bits value, enter boot serialstopbits, followed by the number of stop bits. Options include 1 (default) and 2. For example:
Boot > boot serialstopbits 2
6 Verify your current changes by entering show at the boot prompt:
Boot > show Edit buffer contents: Serial (console) baud : 19200 Serial (console) parity : even Serial (console) stopbits : 2 Serial (console) wordsize : 7
(additional table output not shown)
7 You can save your changes to the boot.params file by entering commit file at the boot prompt:
Boot > commit file
8 You can also save your changes in real time to the switch’s running memory by entering commit system at the boot prompt:
Boot > commit system
9 Return to the CLI prompt by entering exit at the boot prompt.

OmniSwitch 6600 Family Chassis and Hardware Components Console Port
By default, X-ON/X-OFF protocol is enabled on the console port. To enable and disable the X-ON/X-OFF protocol on a console port that you are logged into use the session xon-xoff command by entering session xon-xoff followed by either enable or disable.
For example, to disable X-ON/X-OFF on a console port enter:
-> session xon-xoff disable

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
This section covers the following basic chassis information and monitoring commands:
show hardware info show module show module long (and show ni) show chassis show cmm show session xon-xoff
To view basic hardware information about the switch, enter the show hardware info command at the CLI prompt. This command displays the following information:
For example:
-> show hardware info CPU Type : PowerPC 8245, Flash Manufacturer : SanDisk SDCFB-64 Flash size : 64094208 bytes (61 MB), RAM Manufacturer : Kingston, RAM size : 134217728 bytes (128 MB), NVRAM Battery OK : YES, Interrupt Boot Jumper : OFF, Force UART Defaults Jumper : ON, Run Extended Memory Diags Jumper : OFF, Spare Jumper : ON, BootROM Version : 5.1.5.115.R02, Backup Miniboot Version : 5.1.5.115.R02, Default Miniboot Version : 5.1.5.115.R02

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
Stacked Configurations. For remote sessions (e.g., Telnet and WebView) the show hardware info command displays information for only the primary switch. The command may also be used while connected directly to the primary or secondary switch via the console port. For detailed information on stacked OS6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
To view basic slot position and component information, enter the show module command at the CLI prompt. This command displays the following information:
For example:
HW Mfg Slot Part-Number Serial # Rev Date Model Name + + +---+ +
CMM-1 902098-10 2313283p 210 FEB 05 2106€ OS6648
NI-1 902098-10 2313283p 210 FEB 05 2106€ OS6648
The Slot column lists both the main PCB (CMM) and 10/100 Ethernet bay (NI), along with the switch’s current slot position. CMM-1 and NI-1 indicates that the switch and its corresponding 10/100 Ethernet bay (a virtual Network Interface card) have been assigned to slot position 1.
For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.
Stacked Configurations. You can use the show module command to display information for all switches in a stack, or for a specified switch only. When the show module syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OS6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
To view more detailed slot and component information, including information on installed uplink and stacking modules, use the show module long command.
-> show module

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
This command displays the following information:
For example:
-> show module long CMM in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:00, ASIC - Physical:
(Screen output continued on next page.)

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
Module in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:02, ASIC - Physical:
Daughter Board in port 1 Model Name: OS66MINIGBIC2 , Description: 2pt Giga Fiber, Part Number: 902084-10, Hardware Revision: 201, Serial Number: 2263006P, Manufacture Date: FEB 05 2106€, Firmware Version: , Admin Status: POWER ON, Operational Status: UP
GBIC 1 Model Name: IBM, Description: IBM, Part Number: IBM42P12SNY, Hardware Revision: AA10, Serial Number: 21P704213Z49IBM, Manufacture Date: 01040101, Firmware Version: , Admin Status: POWER ON, Operational Status: UP
Daughter Board in port 2 Model Name: OS66-STK-MOD , Description: 2pt Giga Stack, Part Number: 902086-10, Hardware Revision: 201, Serial Number: 2243041P, Manufacture Date: FEB 05 2106€, Firmware Version: , Admin Status: POWER ON, Operational Status: UP
For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.
Stacked Configurations. You can use the show module long command to display information for all switches in a stack, or for a specified switch only. When the show module long syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
To view basic slot and component information for the base chassis only (i.e., no installed uplink or stack- ing modules), enter the show cmm command at the CLI prompt. This command displays the following information:
For example:
-> show cmm CMM in slot 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Firmware Version: N/A, Admin Status: POWER ON, Operational Status: UP, Power Consumption: 40, Power Control Checksum: 0x0, MAC Address: 00:d0:95:12:ed:00, ASIC - Physical:
For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.
Stacked Configurations. You can use the show cmm command to display information for all switches in a stack, or for a specified switch only. When the show cmm syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”

OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
To view basic chassis information (i.e., no installed uplink or stacking modules), enter the show chassis command at the CLI prompt. This command displays the following information:
For example:
Chassis 1 Model Name: OS6648 , Description: 48PT 10/100 Stack, Part Number: 902098-10, Hardware Revision: 210, Serial Number: 2313283p, Manufacture Date: FEB 05 2106€, Admin Status: POWER ON, Operational Status: UP, Number Of Resets: 271
For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.
Stacked Configurations. You can use the show chassis command to display information for all switches in a stack, or for a specified switch only. When the show chassis syntax is entered with no specified slot number, information for all switches displays. When a slot position is specified in the command line (e.g., 3), information displays for the corresponding switch only. For detailed information on stacked OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
To view the administrative status of the X-ON/X-OFF protocol on a console port, enter the show session xon-xoff command at the CLI prompt. This command displays the following information:
-> show chassis · XON-XOFF Enabled

OmniSwitch 6600 Family Chassis and Hardware Components Managing MAC Addresses on the Switch
Your OmniSwitch 6600 Family switch is shipped with thirty-two factory-installed MAC addresses. These MAC addresses, which are stored on an EEPROM card in the chassis, are used by the switch as unique identifiers for the following functions:
Similar to IP addresses, MAC addresses are assigned by the Internet Assigned Numbers Authority (IANA) and distributed to users in sequential blocks. A sequential block of MAC addresses is referred to as a MAC address range.
The switch’s EEPROM contains two factory-installed MAC address ranges:
MAC Range 1 Reserved for the first two MAC addresses in the factory installed range of 32 MAC addresses. The first—or start—MAC address in this range is always allocated as the base chassis MAC address. The second MAC address is allocated for 802.1X authentication.
MAC Range 3 Contains MAC addresses used for each port in the system.
Number of Factory-installed MAC Ranges 2 (MAC Range 1; MAC Range 3)
Number of MAC Addresses in Default Range 1 2
Number of MAC Addresses in Default Range 3 30
Maximum MAC Ranges on Switch 2 (MAC Range 1; MAC Range 3)
Base chassis MAC address Unique to each switch. The base chassis MAC address is always the first MAC address listed in the switch’s default MAC range 1.
Supported MAC Router Mode Single

OmniSwitch 6600 Family Chassis and Hardware Components Managing MAC Addresses on the Switch
The switch chassis requires a unique identifier in order to be recognized by other devices in the network. The base chassis MAC address, which is automatically allocated by the switch, serves as this identifier. The base chassis MAC address is always the start MAC address listed in the switch’s default MAC range 1.
To display the switch’s base chassis MAC address, use the show mac-range command to display the default MAC range 1. Be sure to specify the MAC range number ( 1 ), as shown below:
-> show mac-range 1
The following information displays:
Mac Local/ Range Row Status Global Start Mac Addr End Mac Addr + 01 ACTIVE GLOBAL 00:d0:95:6a:79:6e 00:d0:95:6a:79:8d
Because MAC address 00:d0:95:6a:79:6e is the first address in default MAC range 1, it is automatically allocated as the base chassis MAC address and, therefore, serves as a unique identifier for the switch as a whole.
To quickly view all allocated MAC addresses, use the show mac-range alloc command. For example:
Mac Local/ Range Row Status Global Start Mac Addr End Mac Addr + 01 ACTIVE GLOBAL 00:d0:95:12:db:60 00:d0:95:12:db:61 03 ACTIVE GLOBAL 00:d0:95:12:db:62 00:d0:95:12:db:7d
In stacked configurations of two or more OmniSwitch 6600 Family switches, the base MAC address for the stack (also referred to as the virtual chassis) is always provided by the primary switch.
If a failover occurs and another switch assumes the primary role, the stack’s base MAC address changes to the address provided by the new primary switch.
For detailed information on stacked configurations, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”
-> show mac-range

Power over Ethernet (PoE) is supported on OmniSwitch 6600-P24 switches and provides inline power directly from the switch’s Ethernet ports. Powered Devices (PDs) such as IP phones, wireless LAN stations, Ethernet hubs, and other access points can be plugged directly into the Ethernet ports. From these RJ-45 ports the devices receive both electrical power and data flow.
Because the feature reduces devices’ dependence on conventional power sources, PoE eliminates many restrictions that traditional electrical considerations have imposed on networks.
In a PoE configuration, power source equipment (PSE) detects the presence of a PD and provides an elec- trical current that is conducted along the data cable. The PD operates using the power received via the Ethernet data cable; no connection to an additional power source (e.g., an AC wall socket) is required.
Note on Terminology. There are several general terms used to describe this feature. The terms Power over Ethernet (PoE), Power over LAN (PoL), Power on LAN (PoL), and Inline Power are synonymous terms used to describe the powering of attached devices via Ethernet ports. For consistency, this chapter and the CLI Command Reference Guide refer to the feature as Power over Ethernet (PoE).
Additional terms, such as Powered Device (PD) and Power Source Equipment (PSE) are terms that are not synonymous with PoE, but are directly related to the feature:
Because OmniSwitch 6600-P24 switches fully support 10/100 Ethernet connectivity, you may also attach non-PD equipment—such as computer workstations, printers, servers, etc.—to the PoE ports. See Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components,” for more information on the OmniSwitch 6600-P24 chassis.

In This Chapter Installing and Managing Power over Ethernet (PoE)
This chapter provides specifications and descriptions of hardware and software used to provide PoE for attached devices.
The chapter also provides information on configuring PoE settings on the switch through the Command Line Interface (CLI). CLI commands are used in the configuration examples; for more details about the syntax of commands, see the OmniSwitch CLI Reference Guide. Topics and configuration procedures described in this chapter include:
page 3-2 OmniSwitch 6600 Family Hardware Users Guide September 2006

Installing and Managing Power over Ethernet (PoE) Power over Ethernet Specifications
The table below lists general specifications for Alcatel’s Power over Ethernet support. For more detailed power supply and Power Source Equipment (PSE) specifications, refer to Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components.”
IEEE Standards supported IEEE 802.3af DTE Power via MDI
Default PoE administrative status Enabled
Default PoE operational status Disabled (PoE must be activated on a switch- by-switch basis via the lanpower start com- mand.)
OmniSwitch 6600 Family platforms supporting PoE OmniSwitch 6600-P24
Backup power supply for the OS6600-P24 OS6600-BPS-P
Cable distances supported 100 meters (approx.)
Total number of PoE-capable ports per OmniSwitch 6600-P24 24
Maximum number of PoE-capable ports per stack 192
Default amount of inline power allocated for each port 15400 milliwatts
Range of inline power allowed for each port 3000–20000 milliwatts
PoE Current draw Approximately 4.3 Amps
PoE Power Approximately 210 watts
Range of inline power allowed for each switch in a stack 37–210 watts

Viewing OS6600-BPS-P Status Installing and Managing Power over Ethernet (PoE)
To view the current status of power supplies installed in the backup power supply, use the show power command as shown below.
-> show power 2 Power Supplies in chassis 2 PS Operational Status + PS-1 UP PS-2 UP
The OS6600-BPS-P will always display as “PS-2”. For detailed information on show power command output, refer to the CLI Command Reference Guide.
page 3-4 OmniSwitch 6600 Family Hardware Users Guide September 2006

Installing and Managing Power over Ethernet (PoE) Configuring Power over Ethernet Parameters
The following table lists the defaults for PoE configuration:
PoE operational status lanpower start or lanpower stop Disabled
Total power allocated to a port lanpower power 15.4 Watts
Total power allocated to an entire OS6600-P24 chassis
lanpower maxpower 210 Watts
Power priority level for a port lanpower priority low
The capacitor detection method lanpower capacitor-detection Disabled
Priority disconnect status lanpower priority-disconnect Enabled
The sections below provide information on each of the key components within the Power over Ethernet software. They include information on PoE-related CLI commands. For detailed information on PoE- related commands, refer to the OmniSwitch CLI Reference Guide.
Enabling PoE
By default, Power over Ethernet is administratively enabled in the switch’s system software. However, in order to physically activate PoE, you must issue the lanpower start command on a slot-by-slot basis before any connected PDs will receive inline power.
To activate power to PoE-capable ports in a switch, enter the corresponding slot number only. For exam- ple:
-> lanpower start 3
If power to a particular port has been disconnected via the lanpower stop command, you can reactivate power to the port by specifying both the slot and port in the command line. For example:
-> lanpower start 3/11

Configuring Power over Ethernet Parameters Installing and Managing Power over Ethernet (PoE)
To disable PoE on a particular slot or port, use the lanpower stop command.
To disable PoE on a specific PoE-capable port, enter a slot/port number. For example:
-> lanpower stop 8/22
To disable PoE for all PoE-capable ports in a slot, enter the corresponding slot number only. For example:
-> lanpower stop 8
By default, PoE automatically allocates 15400 milliwatts for each port on the OmniSwitch 6600-P24 switch. In other words, each port is authorized by the system software to use up to 15400 milliwatts to power any attached device.
You can either increase or decrease this value. Values may range from 3000 to 20000 milliwatts.
Increasing the total power allocated to an individual port may provide a more demanding Powered Device (PD) with additional power required for operation. Decreasing the total power allocated to a port helps preserve inline power and assists in the overall management of the switch’s power budget.
To increase or decrease the total power allocated to an individual port, use the lanpower power command. Because you are setting the power allowance for an individual port, you must specify a slot/port number in the command line. For example, the syntax
-> lanpower 3/12 power 3000
reduces the power allowance on port 12 of the OmniSwitch 6600-P24 switch 3 to 3000 milliwatts. This new value is now the maximum amount of power the port can use to power any attached device (until the value is modified by the user).
Like the maximum port power allowance, the system software also provides a maximum slot-wide power allowance. By default, the switch allocates 210 watts for each OmniSwitch 6600-P24 installed in a stack. In other words, each slot is authorized by the system software to use up to 210 watts to power all devices connected to its ports.
As with the maximum port power allowance, the user can either increase or decrease this value. Values may range from 37 to 210 watts.
Increasing the total power allocated to a slot may provide more demanding Powered Devices (PDs) with additional power required for operation. Decreasing the total power allocated to a slot helps preserve inline power and assists in the overall management of the switch’s power budget.
page 3-6 OmniSwitch 6600 Family Hardware Users Guide September 2006

Installing and Managing Power over Ethernet (PoE) Configuring Power over Ethernet Parameters
To increase or decrease the total power allocated to a slot, use the lanpower maxpower command. Because you are setting the power allowance for an individual slot, you must specify a slot number in the command line. For example, the syntax
-> lanpower 3 maxpower 80
reduces the power allowance of OmniSwitch 6600-P24 slot 3 to 80 watts. This value is now the maxi- mum amount of power the slot can use to power all attached devices (until the value is modified by the user).
Because not all Powered Devices (PDs) connected to the switch have the same priority within a customer network setting, OmniSwitch 6600-P24 switches allow the user to specify priority levels on a port-by-port basis. Priority levels include low, high, and critical. The default priority level for a port is low.
To change the priority level for a particular port, use the lanpower priority command. Because the switch allows you to set priority levels on a port-by-port basis, be sure to specify slot/port information in the command line. For example, the syntax
-> lanpower 8/22 priority critical
changes the priority value of port 22 of OmniSwitch 6600-P24 slot 8 to the highest priority level of criti- cal. Now that the default value has been reconfigured, this port should be reserved for those PDs that are mission critical for network operations.

Configuring Power over Ethernet Parameters Installing and Managing Power over Ethernet (PoE)
By default, the PowerDsine capacitor detection method is disabled on the OmniSwitch 6600-P24. To enable it use the lanpower capacitor-detection command by entering lanpower capacitor-detection followed by the slot number of the OmniSwitch 6600-P24 and enable.
For example, to enable the capacitor detection method on the OS6600-P24 with slot number 2 enter:
-> lanpower capacitor-detection 2 enable
To disable it use the lanpower capacitor-detection command by entering lanpower capacitor-detection followed by the slot number of the OS6600-P24 and disable.
For example, to disable the capacitor detection method on the OS6600-P24 with slot number 2 enter:
-> lanpower capacitor-detection 2 disable
page 3-8 OmniSwitch 6600 Family Hardware Users Guide September 2006

Installing and Managing Power over Ethernet (PoE) Understanding Priority Disconnect
The priority disconnect function differs from the port priority function described on page 3-7 in that it applies only to the addition of powered devices (PDs) in tight power budget conditions. Priority discon- nect is used by the system software in determining whether an incoming PD will be granted or denied power when there are too few watts remaining in the PoE power budget for an additional device. For example, if there are only 2 watts available in the current PoE power budget and a user plugs a 3.5W powered device into a PoE port, the system software must determine whether the device will be powered on. Based on priority disconnect rules, in some cases one or more existing devices may be powered down in order to accommodate the incoming device. In other cases, the incoming device will be denied power.
Priority disconnect rules involve the port priority status of an incoming device (i.e., low, high, and criti- cal), as well as the port’s physical port number (i.e., 1–24). Understanding priority disconnect rules is especially helpful in avoiding power budget deficits and the unintentional shutdown of mission-critical devices when PDs are being added in tight power budget conditions. For detailed information on how priority disconnect uses port priority and port number criteria for determining the power status of incom- ing PDs, refer to the illustrated examples on pages 3-10 through 3-11.
Reminder. Priority disconnect only applies when there is inadequate power remaining in the power budget for an incoming device.
For information setting the priority disconnect status, refer to the section below. For information on setting the port priority status (a separate function from priority disconnect), refer to “Setting Port Priority Levels” on page 3-7.
By default, priority disconnect is enabled in the switch’s system software. For information on changing the priority disconnect status, refer to the information below.
When priority disconnect is disabled and there is inadequate power in the budget for an additional device, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and criti- cal) or physical port number (i.e., 1–24).
To disable priority disconnect, use the lanpower priority-disconnect command. Because the switch allows you to set priority disconnect status on a slot-by-slot basis, be sure to specify the slot number in the command line. For example, the syntax
-> lanpower 2 priority-disconnect disable
disables the priority disconnect function on OmniSwitch 6600-P24 slot 2.
To enable priority disconnect, use the lanpower priority-disconnect command. Be sure to specify the slot number in the command line. For example, the syntax
-> lanpower 8 priority-disconnect enable
enables priority disconnect on OmniSwitch 6600-P24 slot 8.

Understanding Priority Disconnect Installing and Managing Power over Ethernet (PoE)
Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to power an incoming device.
When a PD is being connected to a port with the same priority level as all other ports in the slot, the physi- cal port number is used to determine whether the incoming PD will be granted or denied power. Lower- numbered ports receive higher priority than higher-numbered ports. In other words, a PD connected to Port 1 will have a higher power priority than a PD connected to Port 2; a PD connected to Port 23 will have a higher power priority than a PD connected to Port 24. In order to avoid a power budget deficit, another port in the slot is disconnected. In determining which port to power off, the system software disconnects the port with the highest physical port number.
Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to power an incoming device.
When a PD is being connected to a port with a higher priority level than all other ports in the slot, the incoming PD will automatically be granted power over the other devices, regardless of its physical port number.
In order to avoid a power budget deficit, another port in the slot is disconnected. In determining which port to power off, the system software first selects the port with the lowest configured priority level. For exam- ple, if a critical priority device is being added to a slot in which five existing devices are attached to high priority ports and one device is attached to a low priority port, the low priority port is automatically disconnected, regardless of its physical port number.
If all existing devices are attached to ports with the same lower priority level, the system software discon- nects the port with both the lowest priority level and the highest physical port number. For example, if a critical priority device is being added to a slot in which six existing devices are attached to high priority ports, the high priority port with the highest physical port number is automatically disconnected.
Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to power an incoming device.
When a PD is being connected to a port with a lower priority level than all other ports in the slot, the incoming PD will be denied power, regardless of its physical port number. Devices connected to other higher-priority ports will continue operating without interruption.
page 3-10 OmniSwitch 6600 Family Hardware Users Guide September 2006

Installing and Managing Power over Ethernet (PoE) Monitoring Power over Ethernet via the CLI
Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to power an incoming device.
When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).
To monitor current PoE statistics and settings, use the show lanpower command. The command output displays a list of all current PoE-capable ports, along with the following information for each port:
Aggregate slot and chassis management information also displays. This information includes:

Monitoring Power over Ethernet via the CLI Installing and Managing Power over Ethernet (PoE)
When entering the show lanpower command, you must include a valid slot number in the command line syntax. For example:
-> show lanpower 1 Port Maximum(mW) Actual Used(mW) Status Priority On/Off + 1 15400 0 Powered Off Low ON 2 15400 0 Powered Off Low ON 3 15400 0 Powered Off Low ON 4 15400 0 Powered Off Low ON 5 15400 0 Powered Off Low ON 6 15400 0 Powered Off Low ON 7 15400 0 Powered Off Low ON 8 15400 0 Powered Off Low ON 9 15400 0 Powered Off Low ON 10 15400 0 Powered Off Low ON 11 15400 0 Powered Off Low ON 12 15400 0 Powered Off Low ON 13 15400 0 Powered Off Low ON 14 15400 0 Powered Off Low ON 15 15400 0 Powered Off Low ON 16 15400 0 Powered Off Low ON 17 15400 0 Powered Off Low ON 18 15400 0 Powered Off Low ON 19 15400 0 Powered Off Low ON 20 15400 0 Powered Off Low ON 21 15400 0 Powered Off Low ON 22 15400 0 Powered Off Low ON 23 15400 0 Powered Off Low ON 24 15400 0 Powered Off Low ON Slot 1 Max Watts 210 0 Watts Total Power Budget Remaining 210 Watts Total Power Budget Available 1 Power Supplies Available
page 3-12 OmniSwitch 6600 Family Hardware Users Guide September 2006

In addition to working as individual stand-alone switches, OmniSwitch 6600 Family switches can also be linked together to work as a single virtual switch known as a stack. With stacks you can easily expand your switching capacity simply by adding additional switches. In addition, stacks provide enhanced resil- iency and redundancy features.
The chapter describes basic steps to configure up to eight (8) OmniSwitch 6600 Family switches into a stack. In addition, procedures using Command Line Interface (CLI) commands to monitor the status of stacks are also provided.
Procedures described in this chapter include:

Specifications and Default Values Managing OmniSwitch 6600 Family Stacks
The table below lists specifications for OmniSwitch 6600 Family stacks.
Minimum number of switches in a stack. 2
Maximum number of switches in a stack. 8
Stacking module kits (which include stacking module and cables) model number (OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 only)
OS66-STK-KIT (30 cm cable) and OS66-RST-KIT (1 meter cable)
Stacking port locations on an OmniSwitch 6624, 6600-U24, 6600-P24, and 6602-24 Ports 25 and 26
Stacking port locations on an OmniSwitch 6648 and 6602-48
Ports 51 and 52
The table below lists default values for OmniSwitch 6600 Family stacks.
Switch slot number See “Assigning Slot Numbers” on page 4-8.
page 4-2 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Stack Overview
By default, OmniSwitch 6600 Family switches operate in stand-alone mode. You can also configure two to eight OmniSwitch 6600 Family switches (in any combination of OmniSwitch 6624, 6600-U24, 6600- P24, 6648, 6602-24, and 6602-48 switches) into one large virtual chassis known as a stack. With stacks, you can easily expand your switching capacity simply by adding additional switches. For example, you can start with a stack composed of two switches and add switches (up to eight) as network demands increase.
Note on Terminology. In the user guides provided with your OmniSwitch 6600 Family switch, the terms switch, slot and NI (Network Interface) refer to individual OmniSwitch 6600 Family units in stand-alone mode or within a stack. The term CMM (Chassis Management Module) refers to OmniSwitch 6600 Family units operating in a stack in a primary or secondary CMM role. (OmniSwitch 6600 Family switches operating in an idle CMM role would normally be referred to as a switch, slot, or, NI.)
Stacks also provide enhanced resiliency and redundancy features. If a switch in a stack goes down or is offline, the stack will continue to operate without user intervention. In addition, when a switch auto- synchronizes at boot-up or if you manually synchronize the switches (see “Synchronizing Switches in a Stack” on page 4-17 for more information) switch operating software and configuration parameters are backed up on all switches in the stack. Therefore if software is corrupted or damaged the original operat- ing software and parameters can be recovered.
Switches are connected to each other in a stack with stacking modules. (See Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components,” in this manual for more information.) These stacking modules provide high-speed, dual-redundant links between switches in a stack. The figure below shows an example of a stack composed of four switches. Every switch in a stack is connected to other switches in a stack in a dual-redundant “daisy-chain” manner.
This stack is composed of four OmniSwitch 6648 switches. All switches in this stack are connected together in a dual-redundant “daisy-chain” manner.
EXPANSION 49 50 5 1 5 2
LINK/ACT LINK/ACT
EXPANSION/STACKING
EXPANSION 49 50 5 1 5 2
LINK/ACT LINK/ACT
EXPANSION/STACKING
EXPANSION 49 50 5 1 5 2
LINK/ACT LINK/ACT
CONSOLE
OK1
PS1
PRI
TEMP
FAN
SEL
EXPANSION 49 50 5 1 5 2
EXPANSION/STACKING
OK2
PS2
SEC
LINK/ACT LINK/ACT
CONSOLE
OK1
PS1
PRI
SEC
TEMP
FAN
SEL
OK2
PS2
CONSOLE
OK1
PS1
PS2
PRI
SEC
TEMP
FAN
SEL
OK2
CONSOLE
TEMP
SEL
OK1
PS1
PS2
PRI
SEC
FAN
OK2
A Stack Composed of Four OmniSwitch 6648 Switches

Stack Overview Managing OmniSwitch 6600 Family Stacks
The figure on page 4-3 shows a sample way to connect switches in a four-switch stack to ensure dual- redundant connections. Except for the bottommost switch in the stack, Port 52 is connected to Port 51 on the switch below it with a 30 centimeter stacking cable. On the bottommost switch Port 52 is connected to Port 51 on the topmost switch in the stack with a 1 meter redundant stacking cable. If a stacking connec- tion goes down data can still flow between all the switches in the stack. In addition, if a switch goes down traffic can still flow between the switches that are still operating.
By default, the slot number for OmniSwitch 6600 Family switches is 8. In a stand-alone configuration you would enter 8 when a Command Line Interface (CLI) command requires a slot number. For example, to create VLAN 10 on port 1 on an OmniSwitch 6600 Family with the default slot number you would enter
-> vlan 10 port default 8/1
In a stack, each switch must have a unique slot number, which is configured by the user. (See “Managing Switches in a Stack” on page 4-16 for more information.) This slot number can be any whole number between 1 and 8.
For example, if you have assigned slot number 2 to a switch you would enter
-> vlan 10 port default 2/1
The slot number for each switch is stored in the root /flash directory in the boot.slot.cfg file. This file must exist on every switch in a stack or the stack will not be able to operate correctly. If you accidently delete this file the switch will revert to the default slot number of 8 and will operate in standby mode. To restore the slot number and rejoin the switch to the stack you must physically change the slot by following the steps described in Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components,” and reboot the switch.
page 4-4 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Stack Overview
When OmniSwitch 6600 Family switches operate in a stack, one switch in the stack will always have a primary CMM (Chassis Management Module) software role within the stack. This switch will be responsi- ble for functions such as software and configuration management, web-based management (i.e., WebView), SNMP management, switch diagnostics, and software rollback.
Another switch will have a secondary CMM role. This switch acts as a backup, which is always ready to assume the primary CMM role in the stack if the switch with the primary CMM role fails or goes offline. Any additional switches will have an idle CMM role in the stack. These switches operate similarly to Network Interfaces (NIs) in a chassis-based switch.
By default, the primary—or management—role will be given to the switch with the lowest chassis MAC address. All other switches in the stack will be in non-operational status until slot numbers are assigned by the user and the stack is manually rebooted.
Once unique slot numbers are assigned to switches in a stack, the switch with the lowest slot number will assume the primary CMM role while the switch with the next lowest slot number will assume the second- ary CMM role when the stack firsts boots up. Any other switches in the stack will assume an idle CMM role. For example, in a stack with switches numbered 2, 5, 7, and 8, Switch 2 will assume the primary role, Switch 5 will assume the secondary role while switches 7 and 8 will assume idle roles.
In a stack, if the switch with the primary CMM role fails or goes offline for any reason, all the other switches in the stack are instantly notified. The switch with the secondary CMM role automatically assumes the primary role. In a stack consisting of two switches, the switch that had the primary role will assume the secondary role if it comes back online. In a stack consisting of three or more switches the switch with the next lowest slot number will be assigned the secondary CMM role while the switch that was originally primary will have an idle CMM role if it comes back online.
Note. If a primary switch goes down in a stack consisting of three or more switches and then comes back online again, it will assume an idle CMM role, not the secondary role. If you want a switch with an idle role and the lowest slot number in a stack to regain the primary CMM role you must reboot all the switches in the stack. (See “Resetting All Switches in a Stack” on page 4-18 for more information.)
CMM role redundancy is one of the stack’s most important failover features. The switch with the primary CMM role manages the current switch operations, the switch with the secondary CMM role provides backup (also referred to as “failover”), and any remaining switches in the stack are in an idle CMM role. For CMM redundancy, the software on all the switches in the stack must be synchronized. (Refer to “Synchronizing Switches in a Stack” on page 4-17 for more information.)
The figure on the following page illustrates the CMM failover sequence:
1 Switch 1 is operating in the primary CMM mode. Switch 2 is operating in the secondary mode—i.e., it is functioning with the standby CMM role and is ready to take over chassis management functions in the event of a failure of the switch with the primary CMM role.
2 Switch 1 fails or is taken offline (e.g., the switch is physically removed from the stack).
3 Switch 2 automatically assumes the primary CMM role.
4 Switch 3 automatically assumes the secondary CMM role.
5 Switch 4 remains in the Idle CMM role.

Stack Overview Managing OmniSwitch 6600 Family Stacks
Please note that in this example Switch 1 will assume an idle CMM role if it comes back on line.
Switch 2
(Primary)
Switch 1 fails or is taken offline
!
*If Switch 1 comes back on line it will be in idle mode, not primary or secondary.
CLI Commands Supported on Both the Primary and Secondary Role Switches
Although most CLI commands are executed when logged into the switch with primary CMM role, there is a group of commands that is supported when logged in to either the switch with primary role or the switch with the secondary CMM role. For a list of these commands, refer to the tables below. The tables are grouped by chapter according to the OmniSwitch CLI Reference Guide.
debug chassis auto-reboot show running-directory show reload
show microcode show stack topology
show system show hardware info show chassis
show module show module long show module status
show cmm show ni
cd pwd mkdir rmdir ls dir rename rm
delete cp mv move chmod attrib fsck newfs
ed vi view tty show tty rz more install
page 4-6 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Stack Overview
swlog swlog appid level swlog output show log swlog show swlog
debug ktrace debug ktrace appid level debug ktrace show debug systrace debug systrace appid level
debug systrace show debug systrace show log debug memory monitor debug memory monitor show log
Session Management Commands
show log pmd · session timeout

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Family Stacks
In order to set up a new stacked OmniSwitch 6600 Family configuration, you must complete the follow- ing steps, in the order they are listed:
1 Individually assign slot numbers to all switches
2 Attach all required stacking cables
3 Boot the newly-configured stack
For OmniSwitch 6600 Family switches, the term “slot” refers to the priority status of the switch within the stacked configuration. Slot numbers may range from 1 to 8. For detailed instructions on setting up a stack, refer to the sections below.
Before assigning slot numbers to switches in a stacked configuration, note the following important guidelines:
To assign a new slot number to one or more switches in a stack, follow the steps below:
1 To change the slot number, gently insert a pointed item, such as the open, pointed end of a paper clip, into the small hole (labeled SEL) below the slot number LED on the switch’s front panel. The LED display will begin to flash. You can manually change the slot number as long as the LED continues to flash.
page 4-8 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Setting Up a Stacked Configuration
2 Change the slot number by gently pressing the pointed item into the SEL hole again. Each time the SEL button is pressed, the LED display increases or decreases in increments of one.
TEM
FAN SEL
28 30 32 34
10 12 14 16
SEC
PS2
OK2
CONSOLE
TEMP
SEL
PRI
PS1
FAN
OK1
SEC
OK2
PS2
SEL Button Location
3 Continue pressing the SEL button until you reach the number that is one increment higher that the desired slot number, then hold in the SEL button until the LED decreases one increment (to your desired number) and stops flashing.
4 Power off the switch.
5 Continue steps 1 through 4 for any additional switches that are being assigned new slot numbers.
6 Continue to “Connecting Cables to Stacking Ports” on page 4-11.
TM OmniSwitch 6624

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Family Stacks
Valid Slot Assignments. The illustration at left (showing a stacked configuration with four switches) shows one of many valid slot numbering possibilities.
PRI
TEMP
SEL
OK1
PS1
FAN
OK2
PS2
SEC
PRI
TEMP
SEL
PS1
FAN
OK2
PS2
SEC
CONSOLE
TEMP
SEL
OK1
PS1
FAN
PS2
SEC
OK2
CONSOLE
TEMP
SEL
OK1
PS1
PRI
FAN
PS2
SEC
OK2
Stack of Four Switches with Unique Slot Numbers
page 4-10 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Setting Up a Stacked Configuration
On OmniSwitch 6624, 6600-U24, 6600-P24, and 6648 switches only, note the following important guide- lines before connecting stacking cables to stacking modules:
On all OmniSwitch 6600 Family switches, note the following important guidelines before connecting stacking cables to stacking modules:
To connect stacking cables to stacking modules and link your OmniSwitch 6600 Family switch into a virtual chassis, follow the steps below:
1 Starting from the top of the stack, attach one end of a 30 cm stacking cable to a High Speed Serial Data Connector (HSSDC) port, as shown.
5 1 5 2
Attaching the Stacking Cable to a Stacking Port

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Family Stacks
2 Next, attach the other end of the cable to a HSSDC connector on the switch immediately below. Repeat this procedure until all switches in the stack are connected (see illustrations a, b, and c below).
EXPANSION/STACKING
EXPANSION/STACKING
5 1 5 2
5 1 5 2
5 1 5 2
LINK/ACT LINK/ACT
LINK/ACT LINK/ACT
EXPANSION/STACKING
EXPANSION/STACKING
EXPANSION/STACKING
5 1 5 2
5 1 5 2
5 1 5 2
LINK/ACT LINK/ACT
LINK/ACT LINK/ACT
EXPANSION/STACKING
EXPANSION/STACKING
EXPANSION/STACKING
5 1 5 2
5 1 5 2
5 1 5 2
LINK/ACT LINK/ACT
LINK/ACT LINK/ACT
EXPANSION/STACKING
EXPANSION/STACKING
EXPANSION/STACKING
5 1 5 2
5 1 5 2
5 1 5 2
LINK/ACT LINK/ACT
LINK/ACT LINK/ACT
a b c
Connecting the Switches in the Stack
3 To provide added resiliency and redundancy, it is strongly recommended that you install the optional one-meter stacking cable to connect the top switch in the stack to the bottom switch in the stack. Use the unused HSSDC stacking connectors located at ports 27 and 28 (OS6624, OS6600-U24, OS6600-P24, and OS6602-24) or 51 and 52 (OS6648 and OS6602-48) of each switch, as shown. For more information on stack redundancy and the one-meter stacking cable, refer to “Redundant Stack Connection” on page 4-13.
5 1 5 2
EXPANSION/STACKING
5 1 5 2
EXPANSION/STACKING
5 1 5 2
EXPANSION/STACKING
5 1 5 2
Recommended Redundant Connection Between Switches
4 Now that all switches in the stack are connected, continue to “Booting the Stack” on page 4-14.
page 4-12 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Setting Up a Stacked Configuration
The figure below shows how the redundant connection (provided by the OS66STK-CBL1M cable) between the top and bottom switches in the stack ensures that data will continue to flow throughout the stack, even in the unlikely event of a connection failure between two switches.
No Connection Failure In this example, there is a VLAN with an ingress port on switch 1 and an egress port on switch 2.
Data enters switch 1 via a 10/100 Ethernet
Connection Failure Between Switches 1 and 2 Here, the stacking connection between switches 1 and 2 has gone down unexpect- edly. Data can no longer travel directly between switches 1 and 2.

Setting Up a Stacked Configuration Managing OmniSwitch 6600 Family Stacks
In order for the switches in the stack to operate using their newly-assigned slot numbers, all switches in the stack must be manually booted.
Important. Whenever booting a stacked configuration, note that the primary switch will automatically distribute its system and configuration software to all switches in the stack whenever the virtual chassis boots. During this automatic software synchronization, system and configuration software on the second- ary and idle switches is overwritten. Because the primary switch’s “last known good” software is propa- gated to all switches, the synchronization process helps ensure effective redundancy across the stack.
To manually boot the stack, follow the steps below.
1 Power on all switches by moving the on/off switch for each switch to the on ( | ) position.
2 If back up power supplies are installed in one or more switches in the stack, power on all back up power supplies at this time.
After the stack is completely booted, all switches in the stack operate using the user-assigned slot numbers. To verify the slot numbers for each switch, refer to the slot indicator LED on the front panel of each switch. For more information, refer to “Status LEDs” on page 2-18.
Primary, Secondary and Idle switch status is indicated by the PRI and SEC LEDs. The PRI and SEC LEDs on the switch’s front panel are the most accurate and reliable method for determining the current role of a switch within a stacked configuration.
Now that the stack has been configured and booted, the primary—or management—role should be assigned to the switch with the lowest assigned slot number. In other words, if you assigned a switch in the stack as slot 1, this switch should have the primary role.
To verify this, check the PRI LED on the front panel of the switch with the lowest assigned slot number. The PRI LED should be illuminated solid green.
The secondary role is given to the switch with the next-lowest number.
To verify this, check the SEC LED on the front panel of the switch with the next-lowest assigned slot number. The SEC LED should be illuminated solid green.
page 4-14 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Setting Up a Stacked Configuration
All additional switches with higher numbers will be given idle status. The PRI and SEC LEDs for these switches will be off.
Additional LED Descriptions. For complete descriptions of OmniSwitch 6600 Family LED states, see “Status LEDs” on page 2-18.

Managing Switches in a Stack Managing OmniSwitch 6600 Family Stacks
Most Command Line Interface (CLI) commands can be used to configure OmniSwitch 6600 Family switches operating in either stand-alone or stack configuration. This section describes how to use CLI commands to manage switches operating in a stack.
These functions include reloading switches with a primary or secondary CMM role (see “Reloading a Switch with a Primary or Secondary CMM Role” on page 4-16), synchronizing flash memory in the stack (see “Synchronizing Switches in a Stack” on page 4-17), managing the Chassis Management Module (CMM) roles in a stack (“Changing the Secondary CMM Role to Primary” on page 4-17), and resetting all switches in a stack (“Resetting All Switches in a Stack” on page 4-18).
You can reload a switch with either the primary or secondary CMM role using the CLI’s reload command. For information on using this command, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6600 Family Switch Management Guide. A CMM reload is essentially a soft boot of the switch. Note that you can reload only one switch at a time with this command.
If the switch with the primary CMM role is reloaded, the switch with the secondary CMM role automati- cally takes over primary management functions. In other words, the switch with the secondary CMM role assumes the primary CMM role as soon as the reload is initiated.
If there are only two switches in the stack then the reloaded switch will assume the secondary—or redun- dant—CMM role. If there are three or more switches in the stack then the reloaded switch will assume an idle role when the reload sequence is complete. The idle switch with the lowest slot number will assume the secondary CMM role.
If the switch with secondary CMM role is reloaded, then the idle switch with the lowest slot number will become secondary. The reloaded switch (i.e., the former secondary) will assume an idle role. The switch with the primary CMM role continues all operations without interruption.
page 4-16 OmniSwitch 6600 Family Hardware Users Guide September 2006

Managing OmniSwitch 6600 Family Stacks Managing Switches in a Stack
“CMM” synchronization refers to the process of copying all files in the /flash/working and /flash/ certified directories of the switch with the primary Chassis Management Module (CMM) role to the /flash/working and /flash/certified directories of all the other switches in the stack. (This includes the switch with the secondary CMM role and all the switches with an idle CMM role.)
This synchronization process ensures that these directories match exactly for all switches in the stack. Synchronization prevents any switch in the stack from assuming the primary role with incorrect or outdated software or configuration files.
To synchronize the switches in the stack, enter the following command at the CLI prompt:
-> copy working certified flash-syncro
For more information on CMM synchronization and managing the /flash/working and /flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch 6600 Family Switch Management Guide.
To change a switch with a secondary role to primary use the takeover command. For example, while logged into either the primary or secondary switch enter:
at the CLI prompt. In a stack consisting of two switches the primary switch will become secondary. In a stack consisting of three or more switches the secondary switch will become primary, the idle switch with lowest slot number will become secondary, and the switch that was primary will become idle.
You can determine the current CMM role of a switch by examining the PRI and SEC LEDs on the switch’s front panel. Refer to Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components,” for more information. You can also use the show running-directory command to display whether the switch into which you are currently logged is primary or secondary. For example:
Running CMM : PRIMARY, CMM Mode : DUAL CMMs, Current CMM Slot : 1, Running configuration : WORKING, Certify/Restore Status : CERTIFY NEEDED SYNCHRONIZATION STATUS
In this example, the user is currently logged in to the switch with the primary CMM role.
-> takeover · -> show running-directory

Managing Switches in a Stack Managing OmniSwitch 6600 Family Stacks
If there are no unsaved configuration changes and the flash directories on both the primary and secondary switches in a stack have been synchronized via the copy flash-synchro command, no modules will be reloaded if a takeover occurs. As a result, data flow is not interrupted on the modules during the takeover.
If a configuration change is made to one or more modules (e.g., a VLAN is configured on several differ- ent interfaces), and the changes are not saved via the write memory command, the corresponding modules will automatically reload if a takeover occurs. Data flow on the affected modules will be interrupted until the reload is complete. Note that the modules will reload whether or not the flash synchronization status shows SYNCHRONIZED. This is because the unsaved changes have occurred in the running configura- tion (i.e., RAM), and have not been written to the flash directory’s configuration file. In this case, a list of only the affected modules displays in the table output (e.g., 1 6).
If the flash directories on the primary and secondary management modules are not synchronized (e.g., a copy flash-synchro command has not been issued recently), all modules will be reloaded automatically if a management module takeover occurs. Data flow will be interrupted on all modules until the reload is complete.
To reset all switches in a stack you use the reload all command by entering
at the CLI prompt. This command can be helpful in restoring the original CMM roles in a stack (see “CMM Role Redundancy” on page 4-5).
page 4-18 OmniSwitch 6600 Family Hardware Users Guide September 2006
-> reload all

Managing OmniSwitch 6600 Family Stacks Monitoring Stacks
As shown in the figure below, OmniSwitch 6600 Family stacks can be managed and monitored with Command Line Interface (CLI) commands, WebView, SNMP, and OmniVista. See “Monitoring Stack Topology” on page 4-19 for information on monitoring stack configurations and see Chapter 2, “OmniSwitch 6600 Family Chassis and Hardware Components,” for information on monitoring and moni- toring stack temperature and chassis configurations.
Stacks can be managed and monitored through the console port with CLI commands.
Stacks can be managed and monitored through Ethernet ports with CLI commands, WebView, SNMP, and OmniVista.
To monitor the topology of individual switches within a stack or all switches within a stack use the show stack topology command by entering
-> show stack topology
at the CLI prompt. A screen similar to the following will be displayed:
Link A Link A Link A Link B Link B Link B NI Role State RemoteNI RemoteLink State RemoteNI RemoteLink ---+ 1 PRIMARY ACTIVE 2 27 ACTIVE 2 28 2 SECONDARY ACTIVE 1 51 ACTIVE 1 52
The Role field displays the Chassis Management Module (CMM) role of the switch. The “RemoteNI and “RemoteLink” fields display how the stacking ports are connected to each other within this stack. “Link A” refers to the left-hand stacking port (Port 27 on OS6624, OS6600-U24, OS6600-P24, and OS6602-24 switches and Port 51 on OS6648 and 6602-48 switches) and “Link B” refers to the right-hand stacking port (Port 28 on OS6624, OS6600-U24, OS6600-P24, and OS6602-24 switches and Port 52 on OS6648 and OS6602-48 switches).

Monitoring Stacks Managing OmniSwitch 6600 Family Stacks
In the example on the previous page there are two switches in this stack. Switch 1, which is an OS6648, has the primary CMM role and Switch 2, which is an OS6624, has the secondary CMM role. Switch 1’s left-hand stacking port (Port 51) is connected to Switch 2’s left-hand stacking port (Port 27). Switch 1’s right-hand stacking port (Port 52) is connected to Switch 2’s right-hand stacking port (Port 28). The Link A State and Link B State fields indicate that the links between the switches are currently active and running.
As an option you can display the topology of a single switch in a stack by entering show stack topology followed by the slot number of the switch. For example, to display the topology of switch (slot) you would enter
-> show stack topology 2
at the prompt. A screen similar to the following would be display:
Link A Link A Link A Link B Link B Link B NI Role State RemoteNI RemoteLink State RemoteNI RemoteLink ---+ 2 SECONDARY ACTIVE 1 51 ACTIVE 1 52
page 4-20 OmniSwitch 6600 Family Hardware Users Guide September 2006

and Safety Information
This appendix provides information on regulatory agency compliance and safety for the OmniSwitch 6600 Family.
This equipment is in compliance with the essential requirements and other provisions of Directive 73/23/EEC and 89/336/EEC as amended by Directive 93/68/EEC.
Français: Ce matériel est conformément aux conditions essentielles et à d'autres dispositions de 73/23/EEC et de 89/336/EEC directifs comme modifié par Directive 93/68/EEC.
Deutsch: Konformitätserklärung: CE Kennzeichnung Diese Anlage ist gemäß den wesentlichen Anforderungen und anderen Bestimmungen richtungweisenden 73/23/EEC und des 89/336/EEC, wie von Directive 93/68/EEC geändert.
Español: Este directivo equipo está en conformidad con los requisitos esenciales y otras provisiones 73/23/EEC y 89/336/EEC según la enmienda prevista por Directive 93/68/EEC.
The product at end of life is subject to separate collection and treatment in the EU Member States, Norway and Switzerland and therefore marked with the symbol:
Treatment applied at end of life of the product in these countries shall comply with the applicable national laws implementing directive 2002/96EC on waste electrical and electronic equipment (WEEE).
OmniSwitch 6600 Family Hardware Users Guide September 2006 page A-1

Standards Compliance Regulatory Compliance and Safety Information
The product bears the CE mark. In addition it is in compliance with the following other safety and EMC standards:
OmniSwitch 6624, OmniSwitch 6648, OmniSwitch 6600-U24, and OmniSwitch 6600-P24 switches comply with Class A and Class B standards for digital devices per the FCC Part 15, ICES-003, EN 55022, CISPR 22, AS/NZS 3548, and VCCI standards. Modules with copper connectors meet Class A require- ments using unshielded (UTP) cables, but meet Class B requirements using shielded (STP) cables.
page A-2 OmniSwitch 6600 Family Hardware Users Guide September 2006

Regulatory Compliance and Safety Information Standards Compliance
OmniSwitch 6602-24 and OmniSwitch 6602-48 witches comply with Class A standards for digital devices per the FCC Part 15, ICES-003, EN 55022, CISPR 22, AS/NZS 3548, and VCCI standards.
This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful inter- ference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this guide, may cause interference to radio communications.Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his own expense.
The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user’s authority to operate this equipment.It is suggested that the user use only shielded and grounded cables to ensure compliance with FCC Rules.
If this equipment does cause interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures:
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.
This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set out in the Radio Interference Regulation of the Canadian Department of Communications.
Cet èquipement ne dèpasse pas les limites de Classe A d íèmission de bruits radioèlectriques pour les appareils numèriques,telles que prescrites par le RÈglement sur le brouillage radioèlectrique ètabli par le ministère des Communications du Canada.
This equipment meets the requirements of the Japan Approvals Institute of Telecommunications Equip- ment (JATE).
This is a Class A product. In a domestic environment, this product may cause radio interference. Under such circumstances, the user may be requested to take appropriate countermeasures.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page A-3

Standards Compliance Regulatory Compliance and Safety Information
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

This is a Class A Information Product. When used in a residential environment, it may cause radio frequency interference. Under such circumstances, the user may be requested to take appropriate counter- measure.

page A-4 OmniSwitch 6600 Family Hardware Users Guide September 2006

Regulatory Compliance and Safety Information Translated Safety Warnings
Two people are required when lifting the chassis. Due to its weight, lifting the chassis unassisted can cause personal injury. Also be sure to bend your knees and keep your back straight when assisting with the lifting of the chassis.
Français: Le châssis doit être soulevé par deux personnes au minimum. Pour éviter tout risque d'accident, maintenez le dos droit et poussez sur vos jambes. Ne soulevez pas l'unité avec votre dos.
Zum Anheben des Chassis werden zwei Personen benötigt. Aufgrund des Gewichts kann das Anheben ohne Unterstützung zu Personenschäden führen. Heben Sie das Chassis aus den Knien und halten Sie den Rücken gerade wenn Sie beim Anheben des Chassis assistieren.
Español: Se requieren dos personas para elevar el chasis. Para evitar lesiones, mantenga su espalda en posición recta y levante con sus piernas, no con su espalda.
Because they regulate airflow and help protect internal chassis components, blank cover plates should remain installed at empty module slots and power supply bays at all times.
Français: Les caches blancs remplissent trois fonctions importantes : ils évitent tout risque de choc élec- trique à l'intérieur du châssis, ils font barrage aux interférences électromagnétiques susceptibles d'altérer le fonctionnement des autres équipements et ils dirigent le flux d'air de refroidissement dans le châssis. Il est vivement recommandé de vérifier que tous les caches, modules d'alimentation et plaques de protection sont en place avant d'utiliser le système.
Deutsch: Hinweise zu Abdeckungen Die leeren Modulblenden schützen interne Komponenten und leiten den Luftstrom. Deshalb müssen in allen unbelegten Slots die Modulblenden immer installiert bleiben.
Español: Las tapaderas blancas regulan la circulación de aire y ayudan a proteger componentes internos del chasis y siempre deben estar instaladas en las ranuras vacías del chasis y fuentes de alimentación.
To avoid a shock hazard, do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.
Français: Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Deutsch: Hinweise bei Unwetter Um elektrische Schläge zu vermeiden dürfen während eines Gewitters and diesem Gerät keine Kabel angeschlossen oder gelöst werden, sowie keinerlei Installationen, Wartungen oder Konfigurationen vorgenommen werden.
Español: Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna insta- lación, maintenimiento o reconfiguración de este producto durante una tormenta eléctrica.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page A-5

Translated Safety Warnings Regulatory Compliance and Safety Information
Only personnel knowledgeable in basic electrical and mechanical procedures should install or maintain this equipment.
Français: Toute installation ou remplacement de l'appareil doit être réalisée par du personnel qualifié et compétent.
Deutsch: Installationshinweise Dieses Gerät soll nur von Personal installiert oder gewartet werden, welches in elektrischen und mechanis- chen Grundlagen ausgebildet ist.
Español: Estos equipos deben ser instalados y atendidos exclusivamente por personal adecuadamente formado y capacitado en técnicas eléctricas y mecánicas.
Lasers emit invisible radiation from the aperture opening when no fiber-optic cable is connected. When removing cables do not stare into the open apertures. In addition, install protective aperture covers to fiber ports with no cable connected.
Français: Des radiations invisibles à l'œil nu pouvant traverser l'ouverture du port lorsque aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures. Installez les caches connecteurs prévus à cet effet.
Deutsch: Hinweise zur unsichtbaren Laserstrahlung Die Laser strahlen an der Blendenöffnung unsichtbares Licht ab, wenn keine Glasfaserkabel angeschlos- sen sind. Blicken Sie nicht in die Öffnungen und installieren Sie unverzüglich die Abdeckungen über den Glasfaseranschlüssen.
Español: Debido a que la apertura del puerto puede emitir radiación invisible cuando no hay un cable de fibra conectado, procurar no mirar directamente a las aperturas para no exponerse a la radiación.
page A-6 OmniSwitch 6600 Family Hardware Users Guide September 2006

Regulatory Compliance and Safety Information Translated Safety Warnings
There is a danger of explosion if the Lithium battery in your chassis is incorrectly replaced. Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows: Return the module with the Lithium battery to Alcatel. The Lithium battery will be replaced at Alcatel’s factory.
Français: Il y a un danger d'explosion si la batterie de lithium dans votre châssis est remplacée avec une autre ne correspondant pas aux préconisations constructeur. Il faut donc renvoyer le module en réparation chez Alcatel qui se chargera de remplacer la batterie.
Deutsch: Hinweise zur Lithium Batterie Bei falschem Einsetzen der Lithiumbatterie in das Gerät besteht die Gefahr der Explosion. Bitte ersetzen Sie die Batterie nur durch den gleichen bzw. gleichwertigen Typ, empfohlen durch den Hersteller. Benutzte Batterien entsorgen sie bitte wie folgt: Bitte senden Sie das Modul zurück zu Alcatel. Dort wird die gebrauchte Batterie ersetzt.
Español: Si substituye las pilas de litio en su chasis, siempre utilice el mismo modelo o el tipo equiva- lente de pila recomendada por el fabricante. Deshágase de las pilas usadas según las instrucciones del fabricante. Devuelva el módulo con la pila de litio a Alcatel. La pila de litio será substituida en la fábrica de Alcatel.
Dansk: ADVARSEL! Lithiumbatteri--Eksplosionsfare ved fejlagtig handtering. Udskiftning ma kun ske batteri af samme fabrikat og type. Lever det brugte batteri tilbage tilleverandoren.
To reduce the risk of electrical shock, keep your hands and fingers out of power supply bays and do not touch the backplane while the switch is operating.
Français: Pour réduire tout risque électrique, gardez vos mains et doigts hors des alimentations et ne touchez pas au fond de panier pendant que le commutateur fonctionne.
Deutsch: Hinweise gegen elektrischen Schlag Um die Gefahr des elektrischen Schlages zu verringern, greifen sie bitte nicht in die Spannungsversor- gung und berühren sie nicht die Rückwandplatine während das Gerät arbeitet.
Español: Para reducir el riesgo de descargas eléctricas, no meta sus manos y dedos dentro del chasis de la fuente de alimentación y no toque componentes internos mientras que el interruptor está conectado.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page A-7

Translated Safety Warnings Regulatory Compliance and Safety Information
Your switch is equipped with multiple power supplies. To reduce the risk of electrical shock, be sure to disconnect all power connections before servicing or moving the unit.
Français: Il se peut que cette unité soit équipée de plusieurs raccordements d'alimentation. Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Deutsch: Hinweise zur Spannungsfreischaltung Ihr Gerät ist mit mehreren Netzteilen ausgerüstet. Um die Gefahr des elektrischen Schlages zu verringern, stellen sie sicher, daß alle Netzverbindungen getrennt sind bevor das Gerät gewartet oder bewegt wird.
Español: Antes de empezar a trabajar con un sistema, asegurese que el interruptor está cerrado y el cable eléctrico desconectado.
To avoid shock hazard:
Pour éviter tout risque de choc électrique:
Aus Sicherheitsgründen:
Para evitar peligro de descargas:
page A-8 OmniSwitch 6600 Family Hardware Users Guide September 2006

Regulatory Compliance and Safety Information Translated Safety Warnings
The Getting Started Guide that accompanied this equipment contains important safety information about which you should be aware when working with hardware components in this system. You should read this guide before installing, using, or servicing this equipment.
Français: Avant de brancher le système sur la source d'alimentation, consultez les directives d'installation disponibles dans le “Getting Started Guide”.
Deutsch: Bitte lesen - Sicherheitshinweise Der Getting Started Guide, welcher diese Anlage beiliegt, enthält wichtige Sicherheitsinformationen, über die sie sich beim Arbeiten mit den Hardwareeinheiten bewußt sein sollten. Sie sollten diese Hinweise lesen, bevor sie installieren, reparieren oder die Anlage verwenden.
Español: La 'Getting Started Guide' que acompañó este equipo contiene información importante de segu- ridad sobre la cual usted debe estar enterado al trabajar con los componentes de dotación física en este sistema. Usted debe leer esta guía antes de instalar, usar o mantener este equipo.
This equipment should be installed in a location that restricts access. A restricted access location is one where access is secure and limited to service personnel who have a special key, or other means of security.
Français: Le matériel doit être installé dans un local avec accès limité ou seules les personnes habilitées peuvent entrer.
Deutsch: Hinweis zu Umgebungen mit beschränktem Zutritt Die Anlage sollte an einem Standort mit beschränktem Zutritt installiert sein. Ein Standort mit beschränk- tem Zutritt stellt sicher, daß dort nur Servicepersonal mit Hilfe eines Schlüssels oder eines anderen Sicher- heitssystems Zugang hat.
Español: Este equipo se debe instalar en un sitio con acceso restrinjido. Un sitio con el acceso restrinjido es uno seguro y con acceso limitado al personal de servicio que tiene una clave especial u otros medios de seguridad.
OmniSwitch 6600 Family Hardware Users Guide September 2006 page A-9

Translated Safety Warnings Regulatory Compliance and Safety Information
Because electrostatic discharge (ESD) can damage switch components, you must ground yourself prop- erly before continuing with the hardware installation. For this purpose, Alcatel provides a grounding wrist strap and a grounding lug located near the top-right of the chassis. For the grounding wrist strap to be effective in eliminating ESD, the power supplies must be installed in the chassis and plugged into grounded AC outlets.
Français: L'électricité statique (ESD) peut endommager les composants du commutateur. Pour cette raison Alcatel joint à l'envoi du châssis un bracelet antistatique à brancher sur la prise mise à la terre située en bas à droite du commutateur. Vous devrez mettre ce bracelet avant toute intervention hardware.
Deutsch: Hinweise zur ESD (Elektrostatischen Aufladung) Weil elektrostatische Aufladung (ESD) Teile der Anlage beschädigen könnten, müssen sie sich selbst erden, bevor sie mit der Hardware Installation beginnen. Zu diesem Zweck stellt Alcatel ein Erdungsarm- band und eine Erdungsöse an der oberen rechten Seite des Chassis zur Verfügung. Um eine sichere Erdungsfunktion des Erdungsarmbandes sicherzustellen, müssen die Netzteile installiert und mit dem Schutzleiter des Versorgungsstromkreises verbunden sein.
Español: La descarga electrostática (ESD) puede dañar componentes eletrónicos. Usted debe asegurarse que está en contacto con tierra antes de hacer la instalación del equipo. Con este fin, Alcatel proporciona una pulsera de muñeca para conectar al chasis en la toma de tierra situada en la parte superior derecha del chasis. Para que la correa de muñeca sea eficaz en la eliminación de ESD, las fuentes de alimentación deben estar instaladas en el chasis y conectadas a enchufes CA con tierra adecuada.
page A-10 OmniSwitch 6600 Family Hardware Users Guide September 2006

M MiniGBICs 2-45 MiniGBIC-LH70 2-45 MiniGBIC-LX 2-45 MiniGBIC-SX 2-45 technical specifications 2-45
monitoring 3-4 power cords 2-25 Power on LAN
see PoE Power over Ethernet
see PoE Power over LAN
O OmniSwitch 6600 Family
see PoE power supplies 2-26 backup power supply 2-26 power cords 2-25 redundant AC circuits and 2-30
application examples 1-6 OmniSwitch 6600-24
see OmniSwitch 6624 OmniSwitch 6600-48
see OmniSwitch 6648 OmniSwitch 6600-P24
dimensions 2-10 technical specifications 2-10 OmniSwitch 6600-U24
AC circuit 2-30 backup power supply 2-26 CMM roles 4-5 commands supported on secondary switch 4-6 reload all command 4-18 reload command 4-16
dimensions 2-6 technical specifications 2-6 OmniSwitch 6602-24
dimensions 2-15 technical specifications 2-15 OmniSwitch 6602-48
S session xon-xoff command 2-64 SFPs 2-49 SFP-100-LC-MM 2-49 SFP-100-LC-SM15 2-49 SFP-100-LC-SM40 2-49 SFP-100-MTRJ-MM 2-50 technical specifications 2-49 show chassis command 2-70 show cmm command 2-69 show fan command 2-55, 2-56 show hardware info command 2-65 show lanpower command 3-11 show mac-range command 2-72 show module command 2-66 show module long command 2-66 show ni command 2-67 show power command 2-34 show running-directory command 4-17 show session xon-xoff command 2-70 show stack topology command 4-19 show temperature command 2-53 Smart Continuous Switching 1-3 software rollback 1-4 stacking module
dimensions 2-17 technical specifications 2-17 OmniSwitch 6624
dimensions 2-3 technical specifications 2-3 OmniSwitch 6648
dimensions 2-13 technical specifications 2-13 OS6600-GNI-C2 2-38 technical specifications 2-38 OS6600-GNI-U2 2-36 technical specifications 2-37 OS6600-P24
see OmniSwitch 6600-P24 OS6600-U24
see OmniSwitch 6600-U24 OS6602-24
see OmniSwitch 6602-24 OS6602-48
see OmniSwitch 6602-48 OS6624
see OmniSwitch 6624 OS6648
technical specifications 2-39 stacks 4-1 behavior during takeover 4-18 boot.slot.cfg file 4-4 CMM roles 4-5 default values 4-2 managing 4-16 monitoring 4-19 overview 4-3 resiliency and redundancy 4-4
P pinouts 2-60 PoE 3-1 defaults 3-5 monitoring 3-4, 3-11 priority disconnect 3-9 specifications 2-29, 3-3
Index-2 OmniSwitch 6600 Family Hardware Users Guide September 2006

slot numbers 4-4 specifications 4-2 topology 4-19
T takeover command 4-17 technical specifications
10/100 Ethernet ports 2-3, 2-13, 2-15, 2-17 10/100 PoE ports 2-11 100 Ethernet SFP ports 2-7 backup power supply 2-28, 2-29 console port 2-61, 2-62 MiniGBICs 2-45 OmniSwitch 6600-P24 2-10 OmniSwitch 6600-U24 2-6 OmniSwitch 6602-24 2-15 OmniSwitch 6602-48 2-17 OmniSwitch 6624 2-3 OmniSwitch 6648 2-13 OS6600-GNI-C2 2-38 OS6600-GNI-U2 2-37 pinouts 2-60 SFPs 2-49 stacking module 2-39 temperature management 2-53 danger threshold 2-55 errors 2-55 fan status 2-56 monitoring chassis temperature 2-53 warning threshold 2-55 temp-threshold command 2-55
OmniSwitch 6600 Family Hardware Users Guide September 2006 Index-3
Index · U uplink modules

Index-4 OmniSwitch 6600 Family Hardware Users Guide September 2006
Index
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.