Instruction/ maintenance manual of the product NWS100 3M
Go to page of 20
INST ALLA TION AND OPERA TING INSTR UCTIONS NWS RESIDENTIAL W A TER SOFTENERS MODELS: NWS100 NWS100M NWS150 NWS150M NWS200 NWS200M INSTR2208 0110 Installer , please leave with homeowner .
SAFETY INFORMATION Read, understand, and follow all safety informa tion contained in these instructions prior to installation and use of the NWS Series W ater Softener . Retain these instructions for future reference. Failure to follow installation, operation and maintenance instructions may result in property dama ge and will void warranty .
T ABLE OF CONTENTS SECTION DESCRIPTION 1 BEFORE INST ALLA TION 2 INST ALLA TION 3 REGENERA TION INSTRUCTIONS (Timing Setting Instructions) 4 SERVICE INSTRUCTIONS 5 SPECIFICA TION AND OPERA TING DA T A.
Check Y our Pumping Rate and Water Pressure: T wo water system conditions must be check ed carefully to avoid unsatisfactory operation or equipment damage: 1) MINIMUM water pressure r equired at the water softener inlet is 20 psi (138 kPa).
1-3 Facts to Remember While Planning Y our Installation: 1) All installation procedures MUST conform to local and state plumbing codes. 2 ) If lawn sprinkling, a swimming pool, or geothermal heating/c.
Step 1 (a) Remove control valve by removing quick connect clamp and using a garden hose or bucket, to fi ll SOFTENER T ANK with water (this fi lling method prevents air entrapment tha t can cause loss of resin during initial regeneration proce- dure).
CAUTION T o reduce the risk associated with property damage due to plugged water lines: • P ay particular attention to correct orienta tion of control valve. W ater fl o w should match arrow on control valve. The Inlet and Outlet of other water trea tment equipment products will vary depending on the control valve brand used.
2-3 Step 5 Attach DRAIN LINE to DRAIN LINE FITTING. T o prevent back pressure from reducing fl ow ra te below minimum required for backwash, DRAIN LINE MUST be sized according to run length and relative height.
3-1 SECTION 3: REGENERA TION INSTRUCTIONS INSTRUCTIONS FOR USING REGENERA TION FREQUENCY SCHEDULES: (Time Clock Initiated Models Only) 1) Determine ADJUSTED HARDNESS b y adding three (3) times the iron content in parts per million (ppm) to the hardness in grains per gallon (gpg).
3-2 Model(s) 200 HARDNESS — gpg Persons In Family 5 1 01 52 02 53 03 54 04 55 05 56 06 57 07 58 08 59 0 1 111111111112222222 2 111112222223333334 3 111222233334444666 4 11222333444666666 1 2 5 11223.
3-3 HOW TO SET METER GENERA TION CONTROL: TYPICAL RESIDENTIAL APPLICA TION: T o program, just set the time, set the hardness and it automatically monitors system needs and regenerates only when necessary . T o set time of day , press red time set button and turn 24-hour gear until present time of day is opposite “time of day arrow.
4-1 SECTION 4: SERVICE INSTRUCTIONS Problem Cause Solution 1) Hard water , (unit NOT using salt; liquid level in brine tank NOT too high). A. Electrical ser vice to unit interrupted. A. Assure permanent electrical ser vice (check fuse, plug, pull chain or switch.
5-1 SECTION 5: SPECIFICA TION AND OPERA TING D A T A Timer Initiated Meter Initiated ITEM NWS100 NWS150 NWS200 NWS100M NWS150M NWS200M Nominal Media Volume, cu. ft. (cu mtr) 1.0 (0.03) 1.5 (0.05) 2.0 (0.06) 1.0 (0.03) 1.5 (0.05) 2.0 (0.06) Salt Dosage, lbs (kg): Factory Setting (1) Maximum Setting 6.
6-1 COMPONENTS P ARTS LIST TWO T ANK MODELS (NS & NSM SERIES) REF NO. DESCRIPTION NWS100 NWS100M NWS150 NWS150M NWS200 NWS200M 1 Control Valve, T ime Clock Initiation, with Cover , less Bypass Control Valve, Meter Initia tion, with Cover , less Bypass N100150-5W N12J150-5W N100240-5W N12N240-5W N100240-5W N12R240-5W 2 Adapter Assy .
CONTROL V AL VE -12 DA Y TIMER 6-3.
6-4 ONL Y THOSE P ARTS CIRCLED IN DRA WING AND/OR LISTED BELOW ARE STOCK ITEMS ALL OTHERS ARE SPECIAL ORDER, NON-RETURNABLE P AR TS LIST - 12 DA Y TIMER REF P AR T No. DESCRIPTION A 60353-13 Power Head Assy ., Complete, L/Cover , NS/NLS Series (Incl. Ref.
CONTROL V AL VE - METER INITIA TED 6-5.
6-6 ONL Y THOSE P ARTS CIRCLED IN DRA WING AND/OR LISTED BELOW ARE STOCK ITEMS ALL OTHERS ARE SPECIAL ORDER, NON-RETURNABLE P AR TS LIST - METER TIMER REF P AR T No. DESCRIPTION A 60354-13 Power Head Assy ., Complete, L/Cover , NWS Series (Incl. Ref. Items 2-40) B 14039X Program Wheel Assy .
7-1 SECTION 7: MAINTENANCE REPLENISHMENT OF SAL T SUPPL Y : The salt storage capacity of the brine tank is a pproximately 160 lbs. During each regeneration a specifi c amount of salt is consumed, thus requiring its periodic replenishment (the frequency is dependent on the regeneration schedule).
SECTION 8: LIMITED W ARRANTY For any warranty questions, please refer to the enclosed warranty card or call 1-800-222-7880 or mail your r equest to: 3M Purifi cation Inc . 400 Research Parkw ay Meriden, CT 06450 Aqua-Pure is a trademark of 3M Company used under license .
An important point after buying a device 3M NWS100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought 3M NWS100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data 3M NWS100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, 3M NWS100 you will learn all the available features of the product, as well as information on its operation. The information that you get 3M NWS100 will certainly help you make a decision on the purchase.
If you already are a holder of 3M NWS100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime 3M NWS100.
However, one of the most important roles played by the user manual is to help in solving problems with 3M NWS100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device 3M NWS100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center