Instruction/ maintenance manual of the product ES-5226RS Edimax Technology
Go to page of 59
.
The contents of this manual are based on the tabl e below listing firmware version, software kernel ve rsion, and hardware version. If the switch functions are different f rom the description of the manual, please contact the local sale dealer for more information.
FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Pa rt 15 of the FCC rules. These limits are designed to provide reasonable protection against ha rmful interference in a residential installation.
Content INTRODUCTION...................................................................... 1 Featur es ................................................................................................................ 1 Package Cont ents................
Authentication C onfigurat ion ........................................................................... 13 System IP Conf iguratio n .................................................................................. 14 System St atus ..............
Logout ................................................................................................................. 45 TROUBLESHOOTING .......................................................... 46 Incorrect c onnections ..........................
1 Introduction The ES-5226RS is a multi-port Switch t hat can be used to build high-performance switched workgroup networks. This switch is a stor e-and-forward device that offers low latency for high-speed networking. The switch is targeted at workgroup, department or backbone co mputing environment.
2 Unpack the contents of the ES-5226RS and verify them against the checklist below: ES-5226RS Mounting Plate Power Cord Four Rubber Pads User Manual Compare the contents of the ES-5226RS package with the standard checklist above. If any item is missing or damaged, please contact the local dealer for exchanging.
3 Hardware Description This section mainly describes the hardware of the ES-5226RS and gives a physical and functional overvi ew on the certain switch.
4 2 Giga port: The traditional RJ-45 ports can be used for up-linking wide-band paths in short distance (<100m), or the appropriate replaceable mini-GBIC ports can be used for the application of wideband up-linking and long distance transmissions to fit the flexible field request.
5 LED Indicators The LED Indicators display real-time info rmation of systematic operation status. The following table provides descripti ons of LED status and their meaning.
6 meaning. LED Status Description Green The port works in 1 0/100 Full-duplex or gigabit mode Blinks (continuously) Networking is active Blinks (off for about 2 seconds and on alternatively) The port .
7 Desktop Installation Set the switch on a sufficiently large fl at space with a power outlet nearby. The surface where the user put the switch s hould be clean, smoot h, level and sturdy. Make sure there is enough clearance around the switch to allow attachment of cables, power cord and allow air circulation.
8 [NOTE] For proper ventilation, it allows about at least 4 inches (10 cm) of clearance on the front and 3.4 inches (8 cm) on the back of th e Switch. This is especially important for enclosed rack installation. Power On Connect the power cord to the power socke t on the rear panel of the Switch.
9 Network Application This section provides you a few samples of network topology in which the switch is used. In general, the ES-5226RS is des igned as a segment switch which with its large address table (4k MAC address) and high performance, it is ideal for interconnecting networking segments.
10 Segment Uplink In the illustration below, two Ethernet swit ches (with PCs, pr int server, and local server attached) are connected via 1000- FX or 10/100/1000Base-TX cable. All the devices in this network can communicate with each other through the switches.
11 Web-Based Management This section introduces the configur ation and functions of the Web-Based management. About Web-based Management An embedded HTML web site resides in flash memory on the CPU board of the switch.
12 User Login 1. Launch the Internet Explorer. 2. Key in ‘http://’ and the IP address assigned to the ES-5226RS. Then, press “ Enter ”. 3. The login screen appears. 4. Key in ID & Password. The default login ID and password are “ 1234 ”.
13 Administrator Administrator includes Authentication Conf iguration, System IP Configuration, System Status, and Load Default Setting. Authentication Configuration Change web management l ogin user name and passwor d for the management security issue.
14 System IP Configuration User can configure the IP Settings and DHCP client function in here. IP Address: Manually assign the IP address that the network is using. If DHCP function is enabled, the user doesn’t need to assign the IP address. And, the network DHCP server will assi gn the IP address displaying in this column for the switch.
15 System Status This page displays the information about t he switch’s MAC address, how many ports it has, system version and kernel versi on. Besides, users ca n also fill in up to 12 characters in the Comment field for note. MAC Address: Displays the unique hardware address assigned by manufacturer (default).
16 Default Switch Setting and Reboot Reset switch to default configuration. Click Defau l t to reset all configurations to the default value. Factory Default interface When you see the information as below, close the web windo w and launch again after a while.
17 Port Management Port Management includes Port Configurati on, Port Mirroring, Bandwidth Control, and Broadcast Storm Control. Port Configuration In Port Configuration, you can set and view the operation mode for each port. Auto-Negotiation: Enable and Disable.
18 Port Configuration interface.
19 Port Mirroring The Port mirroring is a method for monito ring traffic in switched networks. That Traffic through ports can be monitored by any of the ports means traffic goes in or out monitored (source) ports will be duplicat ed into mirroring (destination) port.
20 Bandwidth Control Y ou can set up every port’ s frame limitation type and bandwid th rate. Bandwidth Control interface Speed Base: Pull down the selection menu item to choose the speed base in low or high mode. As the picture shows, Port No: Pull down the selection menu to choose a port to be configured.
21 Tx Rate: Pull down the selection menu to choose the transmitting rate. When Speed Base is set as Low, the transmitting ra te for all the ports is in the range between 32K bytes and 8M bytes.
22 Broadcast Storm Control The switch implements a broadcast stor m control mechanism. T ick the check boxes to have them beginning to drop inco ming broadcast packet s if the received broadcast packet count s reach the thres hold defined. Each port’ s broadcast storm protection function can be enabled indivi dually by ticking the check boxes.
23 VLAN Setting A Virtual LAN (VLAN) is a logical net work grouping that limits the broadcast domain, which would allow y ou to isolate network traffi c, so only the members of the same VLAN will receive traffic from the ones of the same VLAN.
24 VLAN Member Setting (P ort Based) interface.
25 VLAN Mode Tagged-based VLAN is an IEEE 802.1Q specification standar d. Therefore, it is possible to create a VLAN across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a “tag” into the Et hernet frames. Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.
26 care, and RemoveTag—for selecting. ¾ Uplink: In normal operation, if the desti nation and source are located in different VLANs, the packets wil l be dropped. Having ticked the radio button, the port is configured as an up-link port which is used in an application such as virus check or fi rewall.
27 VLAN PVID Index Setting The switch supports a 32-ent ry VLAN table to provide 32 active VLANs out of 4096 VLANs defined in IEEE802.1Q. User can define 32 VID entries in the VID table and enable the tag VLAN function. When a tagged packet is received, the switch compares the VID field in the packe t with the ones defined in the VID table.
28 VLAN PVID Index Setting interface.
29 Per Port Counter This page displays the statistics of eac h port. Four counter categories— Receive Packet & Transmit Packet , Collision Count & Transmit Packet , Drop Packet & Receive Packet , and CRC error Packet & Receive Packet — are available to be chosen.
30 Per Port Counter interface.
31 QoS Setting Here you can configure QoS policy prio rity mode and CoS (Class of Service) configuration. QoS (Quality of Service) refers to me chanisms in the network software that make the actual determinati on of which packets have priority. CoS refers to feature se ts, or groups of services, that are assigned to users based on company policy.
32 Priority Mode There are three priority modes available to specify the priority of packets being serviced. Those include First-In-F irst-Out, All-High-Before-Low, and Weight-Round-Robin. First-In-First-Out: Packets are placed into the queue and serviced in the order they were received.
33 Class of Service Configuration Class of Service (CoS) is a 3-bit field within a layer two Ethernet frame header using IEEE 802.1Q. Class of Service (CoS ) is a way of managing traffic in a network .
34 Class of Service Configurat ion interface.
35 Security Filter This function provides the security which only the MAC addresses bound with the port are allowed to access it. Port No: Displays the port number being assigned the MAC addresses. MAC Address: Users can assign up to 3 MAC addresses to the port.
36 MAC Address Filter interface.
37 Trunk Port trunk allows multiple links to be bund led together and act as a single physical link for increased throughput. It provides load balancing, and redundancy of links in a switched inter-network. Actually, t he link does not have an inherent total bandwidth equal to the sum of its component physical links.
38 be aggregated together to fo rm a logic trunk group. Trunk 0: There are four ports—p ort 1 to port 4—can be involved in a trunk group. Tick at least two check boxes and select the trunk type to configure Trunk 0. Trunk 1: There are four ports—p ort 5 to port 8—can be involved in a trunk group.
39 Aggregation Information Having set up the Trunk Conf iguration page in static mo de, you will see the static trunk group information in here. Aggregation Information interface.
40 Configuration Backup/Recovery Backup: This page allows the user to ba ck up the system configuration by copying the text in the field below to a text file. Recovery: If the user wants to re store the previous confi guration, just copies the text from the text f ile and pastes it to the syst em information field.
41 Firmware Update The firmware update function suppor ts web and command prompt window interface for the user to update the fi rmware to the switch. Both the method require the user to type in the password (login password) and type again for password confirmation, then click Updat e to start firmware update process.
42 Updating Firmware to the flash interface After a while, the message shows as below to indicate the user that the update process is complete. Update Complete message on web As for TFTP firmware update, users can get into the command prompt window to proceed.
43 name of the firmware) and press enter to update. Command Prompt Window Note The system will erase the flash at fi rst and then update the new firmware during the update process. If the update process is not finished, the web page of Firmware Update will always be displayed when the switch powe rs on.
44 Reboot Click Reboot to re start the switch. Reboot interface.
45 Logout Having clicked on Logout item in the tr ee menu, the system will ask the user to make sure to log out by clicking the A ccept button or clicking the Back button to return to the previous web page.
46 Troubleshooting This section is intended to help the user solve the most common problems on the ES-5226RS. Incorrect connections The switch port can auto-det ect straight or crossover cable when the user links switch with other Ethernet device. T he RJ-45 connector should use correct UTP or STP cable.
47 Improper Network Topologies It is important to make sure that us ers have a valid network topology. Common topology faults include excessive cabl e length and too many repeaters (hubs) between end nodes. In addition, the user s hould make sure that the network topology contains no data path loops.
48 Technical Specification This section provides the specifications of ES-5226RS. Standard IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX IEEE802.3ab 1000BASE-T IEEE802.3z Gigabit fiber IEEE802.3x Flow control and Back pressure IEEE802.3ad Port Trunk IEEE802.
49 Flash ROM 512Kbytes Power Suppl y 100 ~ 240V AC, 50/60Hz Power Consumption 15.4Watts (Maximum) Operating Temp. 0 o C ~ 45 o C Operating Humidity 10% ~ 90% (Non-condensing) Storage Temp.
50 Appendix 10 /100BASE-TX Pin outs With10/100BASE-TX cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 for receiving data. RJ-45 Pin Assignments Pin Number Assignment 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- [NOTE] “+” and “-” signs represent the polarit y of the wires that make up each wire pair.
51 Straight-through cable schematic Cross over cable schemat ic 10/100/1000Base-TX Pin outs The following figure shows the 10/100/ 1000 Ethernet RJ-45 pin outs.
52 10/100/1000Base-TX Cable Schematic Straight through cables schematic Cross over cables schem atic.
53.
An important point after buying a device Edimax Technology ES-5226RS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Edimax Technology ES-5226RS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Edimax Technology ES-5226RS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Edimax Technology ES-5226RS you will learn all the available features of the product, as well as information on its operation. The information that you get Edimax Technology ES-5226RS will certainly help you make a decision on the purchase.
If you already are a holder of Edimax Technology ES-5226RS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Edimax Technology ES-5226RS.
However, one of the most important roles played by the user manual is to help in solving problems with Edimax Technology ES-5226RS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Edimax Technology ES-5226RS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center