Table of Contents 20 sections U LTRA C LEAN A IR P URIFIER · FAP02 FAP03 · FAPF02 FAPF03 · Table of Contents: · … ShowHide
Page 1 of the 3M FAP03 user manual — FAPF02 FAPF03
Page 1 · click to enlarge
Page 1
3M FAP03 — U LTRA C LEAN A IR P URIFIER diagram (page 1)
Fig. 1

U LTRA C LEAN A IR P URIFIER

Air Purifier Model Series Purificador de aire el número de modelos

Purificateur d’air une pièce Modèles

FAP02 FAP03

Replacement Filter Model Series Filtros de reemplazo número de modelos

Filtre de rechange Modèles

FAPF02 FAPF03

www.filtrete.com

Construction and Home Improvement Markets Division 3M Center, Building 223-4S-02 St. Paul, MN 55144-1000 1800 494-3552 www.3M.com

Filtrete is a trademark of 3M. Filtrete est une marque de commerce de la 3M Company. Filtrete es una marca registrada de 3M Company.

© 3M 2006 34-8518-3189-0 Minimum 10% Post-Consumer Fiber

Page 3 of the 3M FAP03 user manual — Explanation of Signal Words
Page 3 · click to enlarge
Page 3

Safety Information

Safety Information:

Please read, understand, and follow all the safety information contained in these instructions prior to use of the Filtrete™ Ultra Clean Air Purifier. Retain these instructions for future reference.

Intended Use:

The Filtrete™ Air Purifier is intended for indoor household use, using only Filtrete™ brand filters and standard 120V AC power. This air purifier has not been tested with non-Filtrete brand filters, operated at different voltages or used outdoors. Each of these misuses could damage the Air Purifier and/or create unsafe operating conditions

Explanation of Signal Words

Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury.

Page 4 of the 3M FAP03 user manual — Limitation de responsabilité
Page 4 · click to enlarge
Page 4

Warnings and Cautions

  • To reduce the risk associated with fire:
  • Do not block any air vents during use.
  • Do not place the Air Purifier near a heat source.

Assistance ou questionnes Pour plus d’information sur le fonctionnement du purificateur d’air une pièce, visitez notre site Web, à www.3M.com/filtrete ou encore, composez le 1 800 388-3458 à partir des États-Unis ou du Canada.

  • To reduce the risk associated with hazardous voltage:
  • Plug the power cord correctly and tightly into a properly rated electrical outlet.
  • Do not use the Air Purifier if the power cord is frayed or otherwise damaged.
  • Do not touch the power cord with wet hands.
  • Disconnect electrical power before servicing the filter.
  • For indoor dry location use only. Do not use in an outdoor or in a wet envornment.
  • Do not submerge the Air Purifier in water.
  • Do not modify or attempt to modify this product.
  • Do not disassemble the Air Purifier. Except for filter replacement, the Air Purifier is not intended to be serviced and does not contain any serviceable replacement parts or adjustments.

Garantie Garantie limitée. Cet appareil est garanti contre défaut de fabrication ou de main-d’ouvre pendant une période de quatre-vingt-dix (90) jours à compter de la date d’achat. La responsabilité de déterminer si cet appareil convient à une application donnée relève de l’utilisateur. Si ce produit de marque 3M présente une défectuosité pendant la période de garantie spécifiée ci-dessus, le seul recours de l’utilisateur et la seule obligation de 3M est le remplacement ou le remboursement du coût d’achat de l’appareil par 3M et ce, au choix de 3M. Cette garantie ne couvre pas l’usure normale ou les dommages découlant d’un accident, d’une utilisation non adéquate, de l’altération ou du défaut d’entretien raisonnable de l’appareil.

  • To reduce the risk associated with various hazards:
  • Read and understand the operating manual before using the Air Purifier.
  • Do not allow children or pets to have unsupervised access to this product.
  • To reduce the risk associated with environmental contamination:
  • Dispose of the Air Purifier and filters in accordance with local, state, and federal regulations.
  • Replace the filter when the filter change timer begins flashing red. The filter should be changed after no more than 90 days of continuous use. Periodic inspection of the filter for damage or blockage is strongly recommended.

Cette garantie procure des droits légaux spécifiques à l’utilisateur. Il est possible que l’utilisateur ait d’autres droits à cet égard, lesquels peuvent varier d’une province à une autre ou d’un pays à un autre. Pour vous prévaloir des services prévus par la garantie, veuillez communiquer avec 3M en composant le 1 800 388 3458.

To reduce risk associated with hazard voltage, and/or fire: • Plug the Air Purifier into a properly rated electrical outlet.

Limitation de responsabilité

3M ne peut en aucun cas être tenue responsable de quelque perte et de quelque dommage reliés à ce produit 3M et ce, qu’il s’agisse de dommages direct, indirect, spécial ou consécutif, quelle que soit la théorie juridique invoquée, y compris les dommages-intérêts pour violation de garantie, violation de contrat, négligence ou responsabilité absolue. Certaines juridictions ne permettent pas l’exclusion ou la limitation de responsabilité pour les dommages consécutifs; par conséquent, il est possible que l’utilisateur ne soit pas affecté par les exclusions ou limitations énoncées dans la présente garantie.

To reduce the risk associated with hazardous voltage and/or moving blades: • Do not place fingers and/or any objects into air and/or motor housing vents.

To reduce the risk associated with falling, and/or impact: • Do not sit on or place any object on this product.

  • To reduce the risk associated with hazardous voltage, and/or fire, and/or explosion:
  • Do not use any combustible or flammable items on or near the Air Purifier.
  • Do not spill or spray any liquids or aerosols into the Air Purifier or on the filter.
Page 5 of the 3M FAP03 user manual — Dépannage
Page 5 · click to enlarge
Page 5

Dépannage

Installation Requirements

Location Requirements: • Select a location where the air intake and filtered air outlet are not obstructed. • Place the Air Purifier on a flat, level surface at least two feet from any heat source, such as ranges or heaters. • Do not block the air openings or place the Air Purifier on a soft surface such as a bed, chair or sofa. • Operate indoors only. W a r n i n G W a r n i n G Electrical Connection: • Plug the Air Purifier into a 120V AC electrical outlet. • This product is equipped with a polarized AC plug (a plug having one blade wider than the other). This plug will fit into the electrical outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet. DO NOT DEFEAT the safety purpose of this polarized plug in any way. W a r n i n Gical Connection: W a r n i n G • Plug the Air Purifier into a 120V AC electrical outlet. • Plug the power cord correctly and tightly into an electrical outlet. • Do not use the Air Purifier if the power cord is frayed or otherwise damaged. • Do not touch cord with wet hands.
  • L’utilisateur ne doit ni modifier ni tenter de modifier ce produit.
  • L’utilisateur ne doit pas démonter le purificateur d’air une pièce.
  • Seul le remplacement du filtre peut être exécuté par l’utilisateur. Cet appareil ne contient aucune autre pièce pouvant être ajustée, réparée ou remplacée par l’utilisateur.
  • Le filtre de rechange ne tient pas en place :
  • Vérifier le numéro de modèle du purificateur d’air pour s’assurer que le filtre lui convient.
  • S’assurer que le bas du filtre est placé et centré sur la saillie au fond du logement du filtre.
  • Une légère pression vers le bas est requise pour insérer le filtre dans son logement.
  • Assurez-vous qu’aucun objet étranger ne bloque l’ouverture du filtre.
  • Il est impossible de mettre le purificateur d’air en marche :
  • Le purificateur d’air une pièce doit être branché c orrectement dans une prise de 120 V.c.a.
  • Assurez-vous que le purificateur d’air est allumé.
  • Vérifiez si un fusible a grillé ou si le disjoncteur s’est déclenché.
  • Le flux d’air est réduit :
  • Nettoyer le purificateur d’air pour s’assurer que l’entrée d’air et la sortie d’air filtré ne sont pas obstruées.
  • Inspectez le filtre; s’il est sale, remplacez-le par un filtre neuf.
  • L’appareil est très bruyant :
  • Inspectez le filtre; s’il est sale, remplacez-le par un filtre neuf.
  • Assurez-vous que rien n’obstrue l’entrée d’air et la sortie d’air filtré.
Page 6 of the 3M FAP03 user manual — Filter Change Indicator:
Page 6 · click to enlarge
Page 6
3M FAP03 — Features and Functions: diagram (page 6)
Fig. 2 · Features and Functions:

Features and Functions:

Remplacement du filtre

Utilisez seulement les filtres de marque

Filtrete™ dans le purificateur d’air. This Air Purifier from 3M comes complete with the latest advances in air filtration technology in a stylish and trend setting design.

  • Retirez l’emballage en plastique et l’encart en papier du filtre de rechange du purificateur d’air.
  • Assurez-vous que le filtre est aligné correctement. Les flèches situées sur le côté du filtre devraient pointer vers le purificateur lorsque vous installez le filtre.
  • Placer le bord inférieur du filtre neuf dans le logement du filtre et pousser doucement le filtre vers l’intérieur en appuyant sur sa partie supérieure à deux endroits et en le poussant vers l’avant. Une fois que le filtre a dépassé le rebord de retenue supérieur, le relâcher.

Filtration:

Filtrete™ filters use proprietary technology to provide high filtration efficiency and low airflow resistance - the end result is a highly efficient room Air Purifier that operates quietly.

This Filtrete filter has electostatically-charged fibers that can capture particles as small as 0.1 micron. The electrostatically charged fibers are most effective when your filter is new and clean. As particles build up on the filter, they begin to cover up the charged fibers. This will reduce the effectiveness of the fitler at capturing additional particles and can occur early in your filter's life. The time frame and extent of the reduction will depend upon the actual use conditions in the room in your home.

To maximize the air cleaning in the room that contains the Air Purifier, we recommend that you clean and seal, as much as possible, the room in which the Air Purifier operates; continue to dust surfaces and vacuum on a normal schedule; and close all windows and doors during operation.

  • Replacez le couvercle avant en plaçant les languettes du bas du couvercle dans les cavités du purificateur d’air. Poussez la partie supérieure du panneau vers l’appareil jusqu’à ce qu’il soit bien en place.

Filter Change Indicator:

The Air Purifier is equipped with a state-of-the-art filter life analyzer. Unlike timers and other conventional filter change indicators, the analyzer recognizes gradual changes in the filter condition over time and displays a warning signal when it is time to change the filter. If the Air Purifier is used in an environment with high particle concentrations, such as a room with new carpeting, woodworking, etc., the analyzer will detect excessive particle collection and provide a warning to the user to change the filter.

A V E R T I S S E M E N T

  • Le purificateur et les filtres doivent être mis au rebut conformément aux règlements locaux, provinciaux et fédéraux en vigueur.
  • Remplacez le filtre lorsque la minuterie de changement commence à clignoter en rouge. Changer le filtre après au moins 90 jours d’utilisation continue ou avant selon les conditions d’utilisation dans la maison.
  • Une inspection périodique du filtre pour détecter tout dommage ou toute obstruction est fortement recommandée.

To ensure that the air purifier continues to provide effective air cleaning, the filter should be changed after no more than 90 days of continuous use. For this purpose, another change indicator is installed to monitor how long the Air Purifier has operated, not just how many days since the filter was installed. The filter change indicator has been set to indicate filter change for typical household conditions. A yellow caution light will come on when the filter is about 80% used, and a red warning light will come on indicating the filter needs to be changed.

Page 7 of the 3M FAP03 user manual — Retrait du filtre
Page 7 · click to enlarge
Page 7
3M FAP03 — Retrait du filtre diagram (page 7)
Fig. 3 · Retrait du filtre

Retrait du filtre

Cleaning & Resetting the Filter Timer

  • Tout en maintenant le purificateur en place avec une main, ouvrir le couvercle avant avec l’autre main en saisissant et en tirant doucement le couvercle vers soi.
  • Retirer le couvercle et le conserver.
  • Cleaning:
  • Turn the Air Purifier off and unplug it before cleaning.
  • The outside of the Air Purifier can be cleaned with a soft, clean dampened cloth.
  • The filtered air outlet on the top of the unit can be cleaned of dust with a small, soft brush.
  • If you wish to clean the inside of the unit, please only use a dry, soft cloth to wipe it down.
  • Pour retirer le filtre usé, placer les doigts dans les rainures en haut du filtre et appuyer doucement sur le cadre du filtre pour le dégager du rebord de retenue supérieur. Sortir ensuite le filtre usé de l’appareil.
  • Jetez le filtre usé conformément à la réglementation en vigueur.
  • Resetting the Filter Timer:
  • To remind users to change the filter every 90 days, a countdown timer is installed.
  • The reset button is located behind the filter.
  • When the filter is about 80% used, a yellow light will illuminate as a reminder to purchase a replacement filter.
  • When the filter needs to be changed, the yellow light will turn red. Replace the filter immediately by following the instructions in the Filter Replacement section.
  • To reset the filter timer, hold down the FILTER CHANGE button for three seconds. A red light comes on. Before it disappears, the light will start flashing quickly as you continue to hold the button.
3M FAP03 — Retrait du filtre diagram (page 7)
Fig. 4 · Retrait du filtre
  • Pour régler de nouveau la minuterie, pressez le bouton (CHANGEMENT DU FILTRE) pendant 3 secondes. Un témoin rouge s’allume. Avant de s’éteindre, celui-ci clignote rapidement pendant que l’on maintient le bouton enfoncé. La minuterie est maintenant réinitialisée.

The timer is now reset.

To reset the filter timer, the device must be plugged in.

Pour réinitialiser la minuterie du filtre, l’appareil doit être branché.

Page 9 of the 3M FAP03 user manual — Diagnostics de durée utile du filtre :
Page 9 · click to enlarge
Page 9

Air Purifier Use

Fonctionnement du purificateur d’air

M I S E E N G A R D E

  • Turning the Air Purifier On/Off:
  • Ensure the Air Purifier is plugged into a 120V AC outlet properly.
  • Press the (ON/OFF) button on the Air Purifier to turn the unit on.
  • The previous operation of the unit is automatically stored and will automatically be repeated when the purifier is re-started.
  • Once the unit is on, pressing the (ON/OFF) button on the Air Purifier will turn the unit off.
  • Lisez et comprenez le manuel d’utilisation avant d’utiliser le purificateur d’air.

Mise en marche et arrêt du purificateur d’air une pièce :

  • Un témoin vert à intensité variable s’allume sur le bouton de commande. L’appareil ne filtre pas d’air lorsque ce réglage est sélectionné.
  • Le purificateur d’air doit être branché correctement dans une prise de 120 V.c.a.
  • Adjusting the Fan Speed:
  • Once the unit is turned on, the fan speed can be adjusted to one of three settings.
  • The fan speed is displayed on the display above the buttons.
  • Pressing the (SPEED) button will step between the three fan speeds of Low/Medium/High.
  • If the fan speed is set at either Low or Medium, pressing the (SPEED) button will increase the speed to the next highest setting.
  • If the fan speed is set at High, pressing the (SPEED) button will decrease the fan speed to Low.

Réglage de la vitesse du ventilateur :

  • Une fois que l’appareil est allumé, il est possible de régler la vitesse du ventilateur; trois réglages de vitesse sont disponibles.
  • Avec le bouton de commande en position d’arrêt, tourner celui-ci dans le sens horaire pour sélectionner le réglage suivant. Un témoin vert circule au centre du bouton. L’appareil fonctionne alors à un débit de filtration d’air bas.
  • Tourner de nouveau le bouton dans le sens horaire pour sélectionner le débit de filtration d’air moyen. Deux témoins verts opposés circulent au centre du bouton.
  • Le réglage suivant est le débit de filtration d’air élevé, avec trois témoins verts circulant au centre du bouton.

Diagnostics de durée utile du filtre :

  • Filter Life Analyzer Button:
  • At High Speed, the Filter Life Analyzer will perform diagnostics automatically. Yellow, green, and red lights on the display above the buttons will light in alternating order for 10 seconds. After the filter diagnostics are performed, one light will remain lit indicating the filter condition.
  • A green light means that the filter is functioning properly and does not need to be replaced. A yellow light indicates about 80% of the filter has been used, while a red light indicates that the filter should be replaced immediately by following the instructions in the Filter Replacement section.
  • After 30 seconds of illumination, the green light will disappear, while a yellow or red light will stay lit to indicate filter condition.
  • If the device is operating on a speed other than High, you can check the condition of the filter by pressing the filter life analyzer button once. Yellow, green, and red lights will light in alternating order for 10 seconds. After the filter diagnostics are performed, the green light will disappear, while a yellow or red light will stay lit if the filter needs replacement.
  • L’analyseur de durée utile du filtre effectue automatiquement les diagnostics de durée utile du filtre lorsque le débit de filtration d’air élevé est sélectionné. Des témoins jaune, vert et rouge s’allument l’un après l’autre au centre du bouton de commande pendant 10 secondes. Une fois les diagnostics terminés, un seul témoin demeure allumé.
  • Un témoin vert indique que le filtre fonctionne correctement et qu’il ne doit pas être remplacé. Un témoin jaune signifie qu’environ 80 % du filtre a été utilisé. Un témoin rouge indique que le filtre doit être remplacé.
  • Le témoin vert demeure allumé pendant 30 secondes, puis s’éteint; un témoin jaune ou rouge allumé indique l’état du filtre.
  • Si le purificateur fonctionne à un débit de filtration d’air autre qu’élevé, sélectionner le débit élevé pour effectuer les diagnostics de durée utile du filtre.
3M FAP03 — Diagnostics de durée utile du filtre : diagram (page 9)
Fig. 5 · Diagnostics de durée utile du filtre :
  • Read and understand the operating manual before using the Air Purifier.

Ask about the 3M FAP03

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the 3M FAP03

Be the first to ask — other owners or our team will answer.

Original document

3M FAP03 manual PDF

20 pages·748 KB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…