EN
Dometic logo
Official user manual

Dometic RM2354

16 pages·307 KB·Refrigerator·PDF·ENDEFRITNLJA
Dometic RM2354
Table of Contents 42 sections INSTALLATION AND OPERATING INSTRUCTIONS · REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION · RM2354 · FOR YOUR SAFETY · … ShowHide
Page 1 of the Dometic RM2354 user manual — Pour votre sécurité
Page 1 · click to enlarge
Page 1

INSTALLATION AND OPERATING INSTRUCTIONS

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION

RM2354

Dometic RM2354 — REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION diagram (page 1)
Fig. 1

Contents:

Page Installation 4 Operating Instructions 8 Maintenance & Service 12

FOR YOUR SAFETY

Pour votre sécurité

If you smell gas:

Si vous sentez une odeur de gaz:

1. Ouvrez les fenêtres. 2. Ne touchez à aucun interrupteur. 3. Éteignez toute flamme nue. 4. Avertissez immédiatement votre fournisseur de gaz.
1. Open windows. 2. Don’t touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier.

FOR YOUR SAFETY

Pour votre sécurité

Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

USA Corporate Office CANADA Service Office 2320 Industrial Parkway Elkhart, IN 46515 Dometic Distribution Inc. Dometic Corporation 866 Langs Drive 509 South Poplar Street Cambridge, Ontario LaGrange, IN 46761 For Service Center Assistance N3H 2N7 Canada Phone: 260-463-4858 Call: 800-544-4881 Phone: 519-653-4390

825122802 (French 3309571.002)

® · ®

Page 2 of the Dometic RM2354 user manual — INSTALLATION AND OPERATING INSTRUCTIONS
Page 2 · click to enlarge
Page 2
Page 2 of the Dometic RM2354 user manual — INSTALLATION AND OPERATING INSTRUCTIONS
Page 3 of the Dometic RM2354 user manual — Refrigerator control panel
Page 3 · click to enlarge
Page 3
Dometic RM2354 — Refrigerator control panel diagram (page 3)
Fig. 2 · Refrigerator control panel

Refrigerator control panel

A C E

Dometic RM2354 — Refrigerator control panel diagram (page 3)
Fig. 3 · Refrigerator control panel
1. Main Power Button ON/OFF 2 . DC Mode Selector Button 3 . AUTO/GAS Mode Selector Button 4 . Temperature Selector Button

A. DC Mode Indicator Lamp B. AC Mode Indicator Lamp C. GAS Mode Indicator Lamp D. AUTO Mode Indicator Lamp E. CHECK Indicator Lamp (Gas Operation Only) F. Temperature Indicator Lamps

Page 4 of the Dometic RM2354 user manual — INSTALLATION
Page 4 · click to enlarge
Page 4

INSTALLATION

The lower side vent is fitted with a panel, which provides an adequate access opening for ready serviceability of the burner and control manifold of the refrigerator. This should be centered on the back of the refrigerator. CERTIFIED INSTALLATION Certified installations require one roof vent and one lower side vent or optional one upper side vent and one lower side vent. For “Certified Vent System Kits” see page 14. For further information contact your dealer or distribu- tor. METHODS OF INSTALLATION The method of installation is shown in FIG. 3a and 3b. It is essential that all maximum or minimum dimensions be strictly maintained, as the performance of the refrig- erator is dependent on adequate flow of air over the rear of the refrigerator.

GENERAL INSTRUCTION This appliance is designed for storage of foods and storage of frozen foods and making ice.

This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel.

The installation must conform with local codes, or in absence of local codes, the following standards as ap- plicable.

In the U.S. the installation must conform with: 1. National Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edition). 2. Recreational Vehicles Code, ANSI A119.2 (latest edition) 3. Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. If an external electrical source is utilized, the refrigera- tor, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70 - (lat- est edition).

In CANADA, the installation must conform with: 1. Natural Gas and Propane Installation Code, CSA B149.1 2. CSA Z240 RV Series, Recreational Vehicles. 3. Current CSA Z240.4, Gas-equipped Recreational Vehicles and Mobile Housing. If an external electrical source is utilized, the refrigera- tor, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, the Canadian Electrical Code, CSA C22.1, Parts I and II - (latest edition).

FIG. 3a

VENTILATION The installation shall be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle. Openings for air supply or for venting of combustion products shall have a minimum dimension of not less than 1/4 inch.

Proper installation requires one lower fresh air intake and one upper exhaust vent. The ventilation kits shown in this instruction manual have been certified for use with the refrigerator models listed in the Table. For “Certified Vent System Kits” see page 14.

The ventilation kits must be installed and used without modification. An opening toward the outside at floor level in the refrigerator compartment must be provided for ventilation of heavier-than-air fuel gases. The lower vent of the recommended kits is provided with proper size openings. The flow of combustion and ventilating air must not be obstructed.

FIG. 3b

Show 4 more labels / short text on this page
Condenser · Minimum ventilation height · Minimum ventilation height · Condenser
Page 5 of the Dometic RM2354 user manual — D
Page 5 · click to enlarge
Page 5

VENTILATION HEIGHTS Refer to FIG. 3a, 3b and 4.

G

Refrigerator model RM2354Minimum ventilation heights in inches and mm. installation with upper and lower side ventInstallation with roof vent and lower side vent inch mm34 86431 787

K K

CLEARANCES Minimum clearances in inches to combustible materials are: G: Top 0 K: Side 0 L: Bottom 0 M: Rear 1 N: See NOTE: “N” below.

N

N

M

M

NOTE: Ventilation height “N” With upper and lower side vent is “N” the distances be- tween the bottom of the lower side vent to the top of the upper side vent. With roof vent and lower side vent is “N” the distance between the bottom of the lower side vent to the roof material. For ventilation height, see table VENTILATION HEIGHTS. See Figures 3a, 3b and 4.

Side view View from above

D

D

H A W

B

Refrigerator Model RM2354 inch mmOverall DimensionsRecess Dimensions Height AWidth BDepth CHeight HWidth WDepth D 30-5/32 76621-7/8 55622-23/32 57729-3/4 75620-1/2 52121-3/8 542

This method of installation and these clearances will give you adequate space for service and proper installation.

Page 6 of the Dometic RM2354 user manual — INSTALLING REFRIGERATOR IN ENCLOSURE
Page 6 · click to enlarge
Page 6

INSTALLING REFRIGERATOR IN ENCLOSURE

Failure to follow the sequence in securing refrigerator in enclosure can cause leakage between the frame and cabinet. When installing the refrigerator, the installer must block the space between the storage cabinet and the top of the refrigerator, otherwise heat will become trapped in this space, making the top of the refrigerator hot, thus reducing the efficiency of the unit.

NOTE: DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least full width and depth of the appliance. The refrigerator must be installed in a substantial enclo- sure and must be level. When installing the refrigerator in the enclosure, all areas within the recess in which the refrigerator is installed must be sealed. Make sure that there is a complete seal between the front frame of the refrigerator and the top, sides and bottom of the enclosure. A length of sealing strip is ap- plied to the rear surface of the front frame for this pur- pose. Also apply a sealing strip to the foremost floor of the enclosure as shown in fig. 6. The sealing should provide a complete isolation of the appliance’s combus- tion system from the vehicle interior. NOTE: Be careful not to damage the sealing strip when the refrigerator is put in place.

Drain water hose A hole must be drilled through flooring see FIG. 8. The installer MUST make sure that the hose does not kink when run through the floor. Seal around the hose that goes through the drilled hole. If a longer hose than supplied is required to get the water to drain outside of the vehicle, the installer will have to supply the extra length of hose.

GAS CONNECTION Hook up to the gas supply line is accomplished at the manual gas valve, which is furnished with a 3/8" SAE (UNF 5/8" -18) male flare connection. All completed con- nections should be checked for leaks with soapy water.

DO NOT use a flame to check for gas leaks.

The gas supply system must incorporate a pressure regu- lator to maintain a supply pressure of not more than 11 inches water column. When testing the gas supply system at test pressures in excess of 1/2 psi, the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system. When testing the gas supply system at pressures less than or equal to 1/2 psi, the appliance must be isolated from the gas supply piping system by closing its indi- vidual manual shutoff valve. In case detailed instructions on the installation and con- nection to the gas supply are required, contact your dealer or distributor.

Securing the Refrigerator After the refrigerator is put in place, (insuring a combus- tion seal at the front frame), the refrigerator is to be se- cured in the enclosure with five screws (not included). The screws have to be installed in the following order:

1. Four screws installed through the front

frame. See fig. 7.

2. One screw installed in rear base. See fig. 7. In the parts bag there are plugs to be snapped in the front frame to cover the four screw heads.
Page 7 of the Dometic RM2354 user manual — ELECTRICAL CONNECTION
Page 7 · click to enlarge
Page 7

TESTING LP GAS SAFETY SHUTOFF The gas safety shutoff must be tested after the re- frigerator is connected to the LP gas supply.

12 Volts DC Connection This refrigerator model require a continuous 12 volt DC supply to maintain the automatic energy system. The connection is made to the positive (+) and negative (-) terminals of the terminal block on back of the refrig- erator. (See FIG. 1). Correct polarity must be observed when connecting to the DC supply. DO NOT use the chassis or vehicle frame as one of the conductors. Connect two wires at the refrigerator and route to the DC supply. The distance the current must travel from the battery to the refrigerator dictates the AWG wire size to be used. Should the wire be too small for the distance, a voltage drop will result. The voltage drop affects the wattage output of the 12 volt cartridge heater and resultant refrigerator performance. The 12 volt DC heater is fused with a 30 amp. in-line blade fuse. Recommended wire sizes are shown below.

To test the gas safety shutoff, proceed as follows: 1. Start the refrigerator and switch to GAS mode. (See start up instructions). 2. Check that the gas flame is lit and the GAS mode indicator lamp (C) is on. 3. Close the manual gas shutoff valve at the back of the refrigerator. (See FIG. 1). 4. Wait for one minute. The CHECK indicator lamp (E) should be on and the GAS mode indicator lamp (C) should be off. 5. Remove protection cover (see FIG. 1) and open the manual gas shutoff valve. Do not change any button positions on the control panel. Apply a non-corrosive commercial bubble solution to the burner jet orifice. 6. No bubbles should appear at the opening of the burner jet orifice. The presence of bubbles indicates a de- fective gas safety shutoff, and service is required. 7. If no bubbles were present at the burner jet orifice, it should be rinsed with fresh water. Be careful not to damage the burner jet orifice. Replace cover and press the main power ON/OFF button (1) OFF and back ON. Normal operation of the burner should re- turn. Allow the burner to operate for a minimum of 5 minutes.

MAXIMUM TOTAL CONDUCTOR WIRE LENGTH

(In feet and meters)

RM2354

Wire lengthAWG 17 ft. 5 m10 27 ft. 8 m8

ELECTRICAL CONNECTION

120 Volts AC Connection The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards and should be plugged directly into a properly grounded three- prong receptacle. DO NOT cut or remove the grounding prong from this plug. The free length of the cord is 2 feet. and therefore recommended that the receptacle be located to the left side of the refrigerator (viewed from the rear) and approximately 4-6 inches from the floor (see FIG. 8). This allows easy accessibility through the vent door. The cord should be routed to avoid contacting the burner cover, flue cover, or any other components that could damage the cord insulation.

The wires from the battery to the refrigerator must be of large enough size to handle the load. The connections must be clean, tight and free from corrosion. If not, a resulting voltage drop will cause a decreased cooling capacity.

120 Volt AC receptacle

4. 6”

Hole for drain water hose

Page 8 of the Dometic RM2354 user manual — PANEL DIMENSIONS MAX. THICKNESS 5/32" (4 mm)
Page 8 · click to enlarge
Page 8

OPERATING INSTRUCTIONS

CHANGING DOOR SWING TO OPPOSITE SIDE A special Hinge Kit must be used to change door swing. For further information please contact The Dometic Cor- poration listed on the front page.

IMPORTANCE OF LEVELING A REFRIGERATOR In an absorption refrigerator system, ammonia is lique- fied in the finned condenser coil at the top rear of the refrigerator. The liquid ammonia then flows into the evaporator (inside the freezer section) and is exposed to a circulating flow of hydrogen gas, which causes the ammonia to evaporate, creating a cold condition in the freezer. When starting this refrigerator for the very first time, the cooling cycle may require up to four hours of running time before the cooling unit is fully operational. The tubing in the evaporator section is specifically sloped to provide a continuous movement of liquid ammonia, flowing downward by gravity through this section. If the refrigerator is operated when it is not level and the ve- hicle is not moving, liquid ammonia will accumulate in sections of the evaporator tubing. This will slow the cir- culation of hydrogen and ammonia gas, or in severe cases, completely block it, resulting in a loss of cooling.

INSTRUCTIONS FOR MOUNTING THE DOOR PANEL The refrigerator is normally delivered without door panel. The lower decoration strip and parts bag are taped in- side the door. Before starting the mounting work, check that the panel dimensions are in compliance with those given in the Table and the instructions are read thoroughly.

We recommend to mount the panel on the door before the refrigerator is installed in the enclosure.

When mounting the panel, proceed as follows:

  • Slide the panel from the bottom of the door into the grooves on the vertical edges of the door .
  • Push the panel upwards, take the two plastic panel stops from the parts bag and put them in the two holes at the lower door frame.
  • Put the decoration strip across the door and fasten it with three screws from the parts bag.

Any time the vehicle is parked for several hours with the refrigerator operating, the vehicle should be leveled to prevent this loss of cooling. The vehicle needs to be leveled only so it is comfortable to live in (no noticeable sloping of floor or walls).

When the vehicle is moving, the leveling is not critical, as the rolling and pitching movement of the vehicle will pass to either side of level, keeping the liquid ammonia from accumulating in the evaporator tubing. OPERATION Before starting the refrigerator, check that all the manual gas valves are in the ON position. DO NOT forget the manual shutoff valve on the rear of the refrigerator see FIG. 1. This refrigerator is equipped with a semi Automatic Energy Selector (AMES) control system, which can be set to automatically select either 120 volt AC or LP gas operation (AUTO mode), or if desired LP gas only (GAS mode). On 3-way model the control system can manu- ally be set to DC operation (DC mode). The refrigerator controls will work down to 9.6 volt DC.

PANEL DIMENSIONS MAX. THICKNESS 5/32" (4 mm)

REFR.MODELS HEIGHT WIDTH TYPE MAX. MIN. MAX. MIN.

RM2354 inch 25-9/32 25-3/16 19-5/8 19-17/32 mm 642 640 498 496

Most LP gas appliances used in recreational ve- hicles are vented to the outside of the vehicle. When parked close to a gasoline pump, it is pos- sible that the gasoline fumes could enter this type of appliance and ignite from the burner flame, CAUSING A FIRE OR AN EXPLOSION.

FOR YOUR SAFETY, when refueling, shut off all LP gas appliances which are vented to the out- side.

Page 9 of the Dometic RM2354 user manual — Refrigerator control panel
Page 9 · click to enlarge
Page 9

Refrigerator control panel

A

D

E

ON

DC

AUTO

COLD 1 2 3 4 5 COLDEST

OFF AC

GAS

CHECK

B

F

START UP INSTRUCTIONS A. A continuous 12 volt DC supply must be available for

DC MODE 1. Press the DC mode indicator button (2) to turn ON the DC lamp (A). 2. Press the TEMPERATURE SELECTOR button (4) until the lamp at the desired position is illuminated.

the electronic control to function. B. Press the main power ON/OFF button (1) to the

DOWN position. C. Press the TEMPERATURE SELECTOR button (4)

THERMOSTAT The thermostat on the refrigerator, controls both the gas and electric operation, thereby eliminating the necessity of resetting each time a different energy source is em- ployed. After the initial start-up, the thermostat should be moved from “COLDEST” to the desired temperature setting, usually about mid setting.

until the lamp at the desired setting is illuminated.

AUTO MODE 1. Press the DC mode selector button (2) to turn OFF the DC lamp (A). 2. Press the AUTO/GAS mode selector button (3) (if required) to turn ON the Auto lamp (D). If 120 volts AC is available, the AC mode indicator lamp (B) will illuminate indicating AC operation. If 120 volts AC is not available, the GAS mode indicator lamp (C) will illuminate and the control system will automatically switch to GAS operation. 3. If the CHECK indicator lamp (E) illuminates and the GAS mode indicator lamp (C) is off, the controls have failed to ignite the burner in the GAS mode. GAS operation may be reset by pressing the main power ON/OFF button (1) to the OFF then ON posi- tion. (See step 2 under GAS MODE). 4. Press the TEMPERATURE SELECTOR button (4) until the lamp at the desired position is illuminated.

TO SHUT OFF THE REFRIGERATOR The refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button to the UP (OFF) position. This shuts off all DC power to the control system.

GAS MODE 1. Press the DC mode selector button (2) (if required) to turn OFF the DC lamp (A). 2. Press the AUTO/GAS mode selector button (3) to turn OFF the Auto lamp (D). The GAS mode indicator lamp (C) will illuminate. Within 45 seconds the burner should be ignited and operating normally. 3. On the initial refrigerator start-up on gas, it may take longer than 45 seconds to allow air to be purged from the gas line. If the gas does not ignite within 45 sec- onds the CHECK indicator lamp (E) will illuminate and the GAS mode indicator lamp (C) will go off. To reset when the CHECK indicator lamp (E) is illuminated, press the main power ON/OFF button (1) to the OFF and then ON position. NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries. 4. Press the TEMPERATURE SELECTOR button (4) until the lamp at the desired position is illuminated.

Page 10 of the Dometic RM2354 user manual — Refrigerator control panel
Page 10 · click to enlarge
Page 10

Refrigerator control panel

A

D

E

ON

DC

AUTO

COLD 1 2 3 4 5 COLDEST

OFF AC

GAS

CHECK

B

F

DESCRIPTION OF OPERATING MODES

DC MODE When operating in the DC mode the DC mode indicator lamp (A) will be illuminated. All other mode lamps will be off. The DC mode overrides all other operating modes. If one of the other operating modes is desired, the DC selector button (2) must be pressed to turn OFF the DC lamp (A).

AUTO MODE When operating in the AUTO mode, the AUTO mode indicator lamp (D) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again the control will switch back to AC regardless of the status of GAS operation. GAS MODE When operating in the GAS mode the AUTO mode in- dicator lamp (D) will be off and the GAS mode indicator lamp (C) will be illuminated. This mode provides LP gas operation only. The control system will activate the igni- tion system and will make three attempt to light the burner for a period of approximately 45 seconds with two min- utes interval. If unsuccessful, the CHECK indicator lamp (E) will illuminate and the GAS mode indicator lamp (C) will turn off.

IMPORTANT: To prevent the refrigerator from being left on and draining the battery when the vehicle’s engine is not running and charging the battery. It is recommended that an automatic cut-out relay be installed between the battery and the refrigerator toggle switch so that the refrigerator will not draw current when the ignition of the vehicle is switched off. Alternatively, a suitable plug and receptacle should be installed in the 12 Volt supply line, so that the refrigerator can be disconnected from the supply, as necessary.

LIMP MODE OF OPERATION This control system contains a feature where it will con- tinue to operate the cooling system in the event of a fail- ure of a major operating component. Two different modes of operation can occur in this category. If for some reason the display module becomes non func- tional, the control system will revert to full automatic op- eration selecting the best energy source available with AC, DC and GAS priority. The temperature of the refrig- erator will be maintained at the MID position within nor- mal temperature tolerances. The power module will con- tinually attempt to reestablish operation of the display module. The second limp mode of operation will execute when a failure of the temperature sensing device or associated electronic circuitry occurs. If this should occur, the control system will operate on the energy source selected via the control panel. The cooling unit will run continuously on the selected energy source. The refrigerator will continue to operate in this mode in- definitely or until a new sensor is installed and the sys- tem is reset.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. The control system will attempt a new ignition sequence.

If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open. If the problem is still not corrected, con- tact a service center for assistance.

If the control is switched to AC or DC operation while the CHECK indicator lamp is on, it will function properly, but the CHECK indicator lamp will not go off until the main power ON/OFF button is pressed to the OFF then ON position.

Page 11 of the Dometic RM2354 user manual — ! CAUTION
Page 11 · click to enlarge
Page 11

HOW TO USE THE REFRIGERATOR

When all the frost has melted, dry the interior of the re- frigerator with a clean cloth. Replace all food and set the thermostat to the COLDEST temperature setting for a few hours. Then reset the thermostat to the desired set- ting, usually at mid setting.

FOOD STORAGE COMPARTMENT The food storage compartment is completely closed and unventilated, which is necessary to maintain the required low temperature for food storage. Consequently, foods having a strong odor or those that absorb odors easily should be covered. Vegetables, salads etc. should be covered to retain their crispness. The coldest positions in the refrigerator are under the cooling fins and at the bottom of the refrigerator. The warmer areas are on the upper door shelves. This should be considered when placing different types of food in the refrigerator. FROZEN FOOD STORAGE COMPARTMENT Quick frozen soft fruits and ice cream should be placed in the coldest part of the compartment, which is at the bottom of the aluminum liner. Frozen vegetables, may be stored in any part of the compartment. This compartment is not designed for deep or quick freez- ing of food. Meat or fish, whether raw or prepared, can be stored in the frozen food storage compartment pro- vided they are precooled first in the refrigerator. They can be stored about three times longer in the frozen food compartment as compared to the fresh food compart- ment. To prevent food from drying out, keep it in covered dishes, containers, plastic bags or wrapped in aluminum foil. Ice cubes can be made in the freezer compartment. For faster ice making, the trays should be placed in direct contact with the bottom of the freezer compartment. Ice will be made more rapidly if the thermostat is set at its highest position. It is a good idea to do this a few hours before the antici- pated need for ice, but be sure to move back to normal setting, usually about mid setting when the ice is formed. Food in the lower compartment may be frozen if the set- ting is left on “COLDEST” position.

CLEANING THE REFRIGERATOR Cleaning the refrigerator is usually done after it is de- frosted or put into storage. To clean the interior liner of the refrigerator, use lukewarm weak soda solution. Use only warm water to clean the finned evaporator, gasket, ice tray and shelves.

NEVER use strong chemicals or abrasives to clean these parts, as the protective surfaces will be dam- aged. It is important to always keep the refrigerator clean.

SHUT- OFF (STORAGE PROCEDURE) Shut off the refrigerator by pressing the main power ON/ OFF button to the UP (OFF) position. If the refrigerator will not be in operation for a period of weeks, it should be emptied, defrosted, cleaned and the doors left ajar. The ice trays should also be dried and kept outside the cabinet.

DO NOT store explosive substances in the refrig- erator, such as cigarette lighter gas, gasoline, ether or the like. NOTE: Sodium chromate is used for corrosion protec- tion (less than 2 weight % of the coolant).

Total Refrigerated Volume 3 cu.ft.

DEFROSTING Shut off the refrigerator by pressing the main power ON/ OFF button to the UP (OFF) position. Empty the refrig- erator, leaving the drip tray under the finned evaporator, and the cabinet and freezer doors open. Defrosting time can be reduced by filling the ice trays with hot water and placing them in the freezer compartment.

! CAUTION

DO NOT use a hot air blower. Permanent damage could result from warping the metal or plastic parts. DO NOT use a knife or an ice pick, or other sharp tools to remove frost from the freezer compartment. They can create a leak in the ammonia system.

Page 12 of the Dometic RM2354 user manual — BURNER TUBE
Page 12 · click to enlarge
Page 12

MAINTENANCE & SERVICE

Cap the gas supply line, loosen the screws anchoring the refrigerator to the enclosure and slide the refrigera- tor out of the compartment. When replacing the refrigerator make sure that the seal- ing strips are properly positioned. Replacement is the reverse of removal. Check all con- nections for gas leaks. Refer to section INSTALLATION, page 4 to 8. 3. PERIODIC MAINTENANCE To keep your Dometic refrigerator operating efficiently and safely, periodic inspection and cleaning of several components once or twice a year is recommended.

The user should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly. The service should only be per- formed by a qualified technician who is familiar with LP gas systems and refrigerators.

1. HEATER The heat necessary for the operation of an absorption cooling unit is supplied by an electric heater mounted in a pocket of the boiler system. This model is equipped with two electric heaters, one for 120 volt AC and one for 12 volt DC.

A. It is important to keep the area at the back of the

refrigerator clean. Check the lower vent, upper vent and area between these openings for any obstruc- tions such as bird/insect nests, spider webs, etc. Clean the coils on the back of the refrigerator. Use a soft bristled brush to dust off the coils. It is important to keep the refrigerator area free from combustible material, gasoline and other flammable vapors or liquids. NOTE: The following maintenance is required once or twice a year, but should only be done by a qualified ser- viceman who is familiar with LP gas systems and refrig- erators.

To replace the heater proceed as follows:

1. Unplug the refrigerator power cord from the 120- volt AC outlet. 2. Disconnect or shut off the 12 volt DC power to the refrigerator. 3. Remove the power module cover see FIG. 1. 4. Disconnect the 120 V AC heater leads from the power module or the 12 V DC lead from the relay. 5. With a pair of pliers unfold the lug holding the lid of the boiler casing and open the lid. 6. Remove some insulation wool so that the heater is accessible. 7. Turn and lift the heater out of its pocket. 8. Fit the new heater into the pocket. 9. Connect the heater leads and put on the power module cover. 10. Reset the insulation and close the lid of the boiler.

B. Check all connections in the LP gas system (at the

back of the refrigerator) for gas leaks. The LP gas supply must be turned on. Apply a non-corrosive bubble solution to all LP gas connections. The appearance of bubbles indicates a leak and should be repaired immediately by a QUALIFIED SERVICEMAN WHO IS FAMILIAR WITH GAS SYS- TEM AND REFRIGERATORS.

2. REFRIGERATOR REMOVAL Before working on the refrigerator, make sure the AC voltage and DC voltage leads are disconnected. Shut off the gas supply at the LP tank. Disconnect the gas supply line at the rear of the refrigerator, see FIG. 1. Always use a back up wrench when loosening and tightening connections.

DO NOT use a flame to check for gas leaks.

GAS EQUIPMENT ASSEMBLY

NUT

SOLENOID VALVE .

THERMOCOUPLE

INLET FITTING

MANUAL SHUTOFF VALVE . Shown in open position

SPARK ELECTRODE

PRESSURE TEST PORT .

BURNER TUBE

BURNER JET . BURNER MOUNTING SCREW

Page 13 of the Dometic RM2354 user manual — 4. TROUBLESHOOTING
Page 13 · click to enlarge
Page 13

C. Check the AMES control system by connecting/dis-

Clear blue color of flame

connecting 120 volt AC power, start/stop the engine, etc. Compare the operation with the operation de- scribed in section Operating Instructions. D. The LP gas pressure should be checked and the main

regulator readjusted if pressure is incorrect. The cor- rect operating pressure is 11 inches of water column. The correct place to take the LP gas pressure is at the test port just ahead of the burner jet. (See FIG. 9). E. Inspect the flue baffle. It should be reasonably clean

11. Be sure to reconnect the wire to high voltage electrode. Check the electrode for proper location and gap. (See FIG. 11).

and free of soot. Heavy soot formation indicates im- proper functioning of the burner. The flue and burner both require cleaning in the following manner: 1. Unplug the refrigerator power cord from the 120-volt AC outlet. (See FIG. 8). 2. Disconnect or shut off the 12 volt DC power to the refrigerator. 3. Turn manual shutoff valve to OFF. (See FIG. 1 & 9). 4. Remove cover from the burner housing. (See fig. 1). 5. Disconnect the wire from the high voltage electrode. 6. Remove the burner mounting screw and remove the burner assembly. (See FIG. 9). 7. Remove the wire and flue baffle from the top of flue tube. Clean the flue from the top using a flue brush. Blowing compressed air into the flue will not prop- erly clean soot and scale out of the flue tube. Replace the flue baffle. 8. Clean burner tube with a brush. Blow out burner with compressed air. 9. Before removing burner jet, clean burner area of soot and scale that fell out of flue tube. Remove the burner jet. Soak the jet in wood alcohol and blow it out with compressed air. Reinstall and tighten burner jet.

FIG. 11 Electrode

1/8” to 3/16” (3-5 mm)

12. Turn on manual gas shutoff valve and check all fittings for leaks with soapy water. 13. Connect 120-volt power cord to the outlet and reconnect or turn on the 12-volt DC power. 14. Check LP gas safety shutoff. See page 7.

F. FUSES The refrigerator is equipped with 3 fuses, two fuses in the power module and one in-line blade fuse.

Power module To replace fuse(s) proceed as follows. 1. Disconnect the wall plug, and the 12 volt wires. 2. Remove the power module cover. See FIG. 1. 3. Snap the fuse out of the fuse holder. 4. Fit a new fuse in to the fuse holder. 5. Replace the power module cover.

DO NOT use a wire or pin when cleaning the burner jet as damage can occur to the precision opening. This can cause damage to the refrigerator or create a fire hazard.

Control system 3 Amp AC heater 5 Amp

In line fuse 30 amp. blade fuse for the 12 volt DC heater

4. TROUBLESHOOTING

Refrigerator Does Not Cool Properly

10. Reinstall burner, being careful that the end of the burner fits into the slot on the burner bracket. Check to make sure slots are centered under the flue tube and the thermocouple is positioned properly (tip of thermocouple extends over two slots of burner).

A. Burner jet clogged.

Clean. (See section Maintenance & Service, Item 3. Periodic Maintenance, Paragraph E. Item 1-14). B. Check level of refrigerator. C. Venting problem.

Restriction in air flow across cooling unit. D. Heavy frost buildup on evaporator fins.

Defrost E. Flue baffle not inserted properly in flue tube.

Burner tube

Page 14 of the Dometic RM2354 user manual — CERTIFIED VENT SYSTEM KITS
Page 14 · click to enlarge
Page 14

F. Improperly set thermostat.

SPARE PARTS

See section Operating Instructions, part Start Up Instructions. G. Burner dirty.

The following list is a list of commonly used parts, which should be available, if required, from your Dometic Ser- vice Center.

Clean. (See section Maintenance & Service, Item 3. Periodic Maintenance, Paragraph E. Item 1-14). H. LP gas pressure low at burner.

Part No. Description

Set main regulator so pressure does not drop below 11 inches of water column at pressure test port (See FIG. 9). I. Burner not located properly under flue tube. Relocate J. Burner damaged.

17 37 35-06/9 Heater, 150W, 12V 17 37 71-02/3 Heater, 175W, 120V 200 22 61-24/2 Door shelf, 3 pieces 200 71 72-02/2 Baffle 200 74 19-15/9 Jet, No.39 293 27 81-01/2 Electrode 293 06 97-07/9 Burner 293 20 52-01/8 Thermocouple 293 26 36-01/8 Box 293 11 32-02/7 Spark ignition device

Replace K. Odor from fumes.

1. Dislocated burner 2. Damaged burner 3. Dirty flue tube L. FUSES
1. Refrigerator control system 2. Refrigerator AC Supply 3. In-line blade fuse for 12 volt DC heater See section Maintenance & Service, item 3. Periodic Maintenance, Paragraph F.

Hinge Kit from right to left and left to right 385 03 04-01/9 (light brown)

Hinge Kit from right to left and left to right 385 03 04-02/7 (black)

Contact an authorized service center for parts and repairs as needed

All the above instructions are to be followed closely. The refrigerator is quality-guaranteed. However, we are not responsible for any failures caused by improper adjust- ments and unfavorable installation conditions. Contact service point or distributor service dept. for assistance.

CERTIFIED VENT SYSTEM KITS

REFRIGERATOR KIT MODEL NO. COMPONENTS PART NO.

RM2354 2A Roof Base 3103633.XXX* Roof Cover 3103634.XXX* Lower Side Vent 3109350.XXX* Lower Side Vent RM183

3A Upper Side Vent RM123A Lower Side Vent RM183

Power Vent Asm. 3108705.751** Upper Side Vent RM123A Upper Side Vent 3109492.003 Lower Side Vent RM183 Lower Side Vent 3109492.003

* Fill in “XXX” with color code numbers. For color codes, contact your supplier. ** Alternate instructions forwarded with the Ventilator Kit.

For further information contact your dealer or distributor.

Page 15 of the Dometic RM2354 user manual — Removing and replacing of shelves (General)
Page 15 · click to enlarge
Page 15

Removing and replacing of shelves (General)

The number of shelves and position may vary between refrigerator models.

Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 4 · Removing and replacing of shelves (General)
Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 5 · Removing and replacing of shelves (General)

Put a screwdriver into the slot of the shelf lock. Turn the screwdriver counterclockwise. Remove the shelf locks from the wire shelf.

Insert the ends of the wire shelf on the left-hand side at the desired position.

Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 6 · Removing and replacing of shelves (General)
Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 7 · Removing and replacing of shelves (General)

Slide the wire shelf to the left. The right-hand side of the shelf will come loose.

Slide the shelf into the holes on the right-hand side.

Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 8 · Removing and replacing of shelves (General)
Dometic RM2354 — Removing and replacing of shelves (General) diagram (page 15)
Fig. 9 · Removing and replacing of shelves (General)

Lower the right-hand side of the wire shelf and let the left-hand side slide out of the holes in the wall.

Slide the plastic plugs into the holes of the wall. Snap the shelf locks onto the wire shelf.

Page 16 of the Dometic RM2354 user manual — MO-FO 0438
Page 16 · click to enlarge
Page 16

RM2354

Dometic RM2354 — RM2354 diagram (page 16)
Fig. 10

MO-FO 0438

Ask about the Dometic RM2354

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dometic RM2354

Be the first to ask — other owners or our team will answer.

Original document

Dometic RM2354 manual PDF

16 pages·307 KB·Refrigerator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…