Dimensions Model(s) Specification WFC 3NB 3kW, Switch, Thermostat & Neon - Black WFC 3NS 3kW, Switch, Thermostat & Neon - Silver
Dimplex Wall-mounted Fan Convector 08/18724/2 Issue 2 Models : WFC 3NB and WFC 3NS
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
Installation Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring. Supply cable is not provided with this appliance, and a competent electrician should therefore install it. The appliance must be fitted horizontally with the cable or conduit entry at bottom right. It should be mounted such that the underside is at least 350mm above the floor and the top of the heater is 150mm below any overhanging shelf or obstruction. This heater must be used on an A.C.~ supply only and the voltage marked on the heater must correspond to the supply voltage. To comply with the I.E.E. Wiring Regulations, the appliance must be earthed; the supply circuit must be adequate for the input of the appliance, and the circuit protected by a suitable 13A fuse. A suitable termination to the fixed wiring of the premises must be provided adjacent to the final position of the appliance. In this instance, such a termination can be a double- pole switch with a contact separation of at least 3mm in all poles. The heater must not be located immediately below a fixed socket-outlet. Electrical WARNING : THIS APPLIANCE MUST BE EARTHED.
IMPORTANT SAFETY ADVICE WARNING – THIS APPLIANCE MUST NOT BE USED IN A BATHROOM. WARNING – DO NOT USE THIS HEATER IN THE IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL. WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A FIXED SOCKET OUTLET. DO NOT USE THE HEATER UNTIL IT IS WALL MOUNTED CORRECTLY. The heater carries a warning 'Do Not Cover' to alert the user to the risk of overheating that exists if the heater is accidentally covered. NEVER cover or obstruct in any way the air inlet slots at the front of the heater or the heat outlet slots in the base of the heater. Keep combustible materials such as drapes and other furnishings clear from the front of the heater. Do not use heater to dry your laundry. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance. If young children, the aged, or infirm are likely to be left in the vicinity of the heater, we advise that adequate precautions should be taken. We recommend that a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product. WARNING: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.Do not use where excessive dust or moisture is present. For further information, please contact our guard supplier direct on Tel. No. 01603 667957, or in the case of difficulty or for further advice contact the Customer Helpline.
After ensuring the electricity supply is not live, electrical connections can be made, either to an adjacent double-pole switch having a contact separation of at least 3mm in all poles or to a plug-top for use in a standard 13A socket. If the latter: Connect Green and Yellow wire to
Green or Green and Yellow. Connect Blue wire to plug terminal marked N or Black. Connect Brown wire to plug terminal marked L or Red. Refit cover, first hooking top over the back of the unit and then securing the bottom by refitting the two screws under the bottom edge. The appliance is now ready for use and the electricity supply can be reinstated.
plug terminal · marked E or


cable or conduit entry 350mm min. 35mm

Thermal Safety Cut-out In the event that the appliance overheats, the cut-out switches the heater off automatically. To bring the heater back into operation, remove the cause of overheating, then turn Off the electrical supply to the heater for a few minutes. When the heater has cooled sufficiently reconnect and switch On the heater. If the cut-out operates repeatedly, contact your supplier.
To control the room temperature, set the mark on the thermostat knob to the required temperature on the visually graduated scale (see Fig. 4). The thermostat will monitor continuously the temperature of the air returning to the inlet grille, and the heater element(s) selected will achieve or maintain the chosen temperature level efficiently and economically.
When running Fan only modes, rotate thermostat knob to ‘max.’ position to ensure continuous cool air


For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.

After Sales Service Your product is guaranteed for one year from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge (excluding element & subject to availability) provided it has been installed and operated in accordance with these instructions. Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. Should you require after sales service you should contact our customer services help desk on 0845 600 5111. It would assist us if you can quote the model number, series, date of purchase, and nature of the fault at the time of your call. The customer services help desk will also be able to advise you should you need to purchase any spares. Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service. Please retain your receipt as proof of purchase.
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336 Glen Dimplex UK Limited UK customer help line 8.00AM – 5.00PM Mon-Fri; 8.30AM-1.00PM Sat (Autumn-Winter only) Millbrook House Grange Drive Customer Services: Tel. 0845 600 5111 Hedge End Fax. 01489 773053 Southampton e-mail customer.services@glendimplex.com Hampshire. SO30 2DF Republic of Ireland Tel. 01 8424833
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Ltd.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.