Rev ersible Luft/W asser- Wärmepumpe für Innenaufstellung LIK 8MER Rev ersible Air-to-W ater Heat P ump for Indoor Installation P ompe à chaleur air-eau rév ersible pour installation intérieur e .
E-1 English Table of contents 1 Please Read Immediately ................................................ .......................................... ............. ...... E-2 1.1 Important Information: ..................... ................... .........
www.dimplex.de E-2 English 1.3 1 Please Read Immediately 1.1 Important Information: ATTENTION! The device is not suitable for ope ration with a frequency converter. ATTENTION! When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction).
E-3 English 2 2 Purpose of the Heat Pump 2.1 Application The air-to-water heat pump is designed for use in existi ng or newly built heating systems. It is desi gned exclusiv ely for heatin g and cooli.
www.dimplex.de E-4 English 4 3.2 Switch Box The switch box is located in the heat pump. It can be accessed by removing th e lo we r fro n t cov e r. The switch box contains t he supply conn ection termi nals, as well the power cont actors, the soft sta rter unit and the heat pump manager.
E-5 English 5 5S e t - U P 5.1 General Information The heat pump is designed for instal lation in a corner. Other in- stallation lo cations are also possible in combi nation with an air duct (available as an accessory) on th e air outlet side. The unit must be installed ind oors on a level, smooth and hori- zontal surface .
www.dimplex.de E-6 English 6.4 The air outlet can be optionally mounted directly to a wall open- ing or to a longer duct (ava ilable as an accessory ).
E-7 English 7 7 Start-UP 7.1 General Information To ensure that start-up is performed correctly, it shou ld only be carried out by an after-sales servic e technici an authorise d by the manufacturer. This ma y be a condi tion f or exten din g the guaran - tee (see Warranty Service).
www.dimplex.de E-8 English 10 8 Maintenance / Cleaning 8.1 Maintenance To protect th e paintwork, a void leaning or putting obj ects on the device. External heat pump parts can be wiped wi th a damp cloth and domestic cleaner. ATTENTION! Never use clea ning agents containing sand, soda, acid or chloride as these can damage the surfaces.
E-9 English 11 11 Device Information 1 Type and order code LIK 8MER 2D e s i g n 2.1 Model Compact 2.2 Degree of protection according to EN 60 529 for compact devices and heating components IP 20 2.3 Installation location Indoors 3 Performanc e data 3.
www.dimplex.de A-I Anhang · Ap pendix · Annex es Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas co tés ................................................................... A-II 1.1 Wärmepumpe / Heat pump / Pompe à chaleur .
A-II Anhang · Ap pendix · Annex es 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Wärmepumpe / Heat pump / Pomp e à chaleur [,QQHQJHZLQGH0[ .
www.dimplex.de A-III Anhang · Ap pendix · Annex es 1.2 1.2 Einbaumaße / Installation Di mensions / Cotes de montage /XIWULFKWXQJ 'LUHFWLRQRIDLUIORZ 6HQVGpFRXOHPHQWDLU .
A-IV Anhang · Ap pendix · Annex es 2 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating Operation / Mode chauffage .
www.dimplex.de A-V Anhang · Ap pendix · Annex es 2.2 2.2 Kühlbetrieb / Cooling Operat ion / Mode refroidissement .KOOHLVWXQJLQ>N:@ &RROLQJFDSDFLWLQ>N:@ 3XLVVDQFHGH.
A-VI Anhang · Ap pendix · Annex es 3 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Cont rol of the standard controller / Commande régulateur standard.
www.dimplex.de A-VII Anhang · Ap pendix · Annex es 3.2 3.2 Steuerung Kühlregler / Control of the cooling contro ller / Commande régulateur standard :HJH8PVFKDOWYHQWLO )RXUZDUHYHUVLQ.
A-VIII Anhang · Ap pendix · Annex es 3.3 3.3 Last / Load / Charge.
www.dimplex.de A-IX Anhang · Ap pendix · Annex es 3.4 3.4 Anschlussplan Standardregler / Te rminal diagram for the standard controller / Schéma électriqu e du régulate ur standard.
A-X Anhang · Ap pendix · Annex es 3.5 3.5 Anschlussplan Kühlregler / Te rminal diagram for the cooling controller / Schéma électrique du régulateur refroidissement 7 HPSHU 7 HPS 7 HP.
www.dimplex.de A-XI Anhang · Ap pendix · Annex es 3.6 3.6 Legende / Legend / Légende A1 Drahtbrücke einlegen wenn kein Sper rschütz benö- tigt wird (Brücke offen = EVU-Sperre = WP „aus“) In.
A-XII Anhang · Ap pendix · Annex es 3.6 R1 Außentemperaturfühler Exter nal temperature sensor Sonde de température extérieure R2 Rücklauffühler-Heizung Return flow sensor for heating system So.
www.dimplex.de A-XIII Anhang · Ap pendix · Annex es 4.1 4 Hydraulisches Prinzips chema / Hydraulic Plumbing Diagram / Schéma hydraulique 4.1 Darstellung / Schemati c view / Représentation.
A-XIV Anhang · Ap pendix · Annex es 4.2 4.2 Legende / Legend / Légende Absperrventil Shutoff valve Robinet d’arrêt Überstromventil Overflow valve Vanne de trop-plein Sicherheitsventi lkombinati.
www.dimplex.de A-XV Anhang · Ap pendix · Annex es 5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité.
Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors.
An important point after buying a device Dimplex LIK 8MER (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dimplex LIK 8MER yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dimplex LIK 8MER - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dimplex LIK 8MER you will learn all the available features of the product, as well as information on its operation. The information that you get Dimplex LIK 8MER will certainly help you make a decision on the purchase.
If you already are a holder of Dimplex LIK 8MER, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dimplex LIK 8MER.
However, one of the most important roles played by the user manual is to help in solving problems with Dimplex LIK 8MER. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dimplex LIK 8MER along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center