Instruction/ maintenance manual of the product LA 17PS Dimplex
Go to page of 26
Luft/W asser- Wärmepumpe für A ußenaufstellung L A 17PS L A 22PS L A 26PS Air-to-W a ter Hea t Pump f or Outdoor Installation P ompe à chaleur air-eau pour installation extérieure Montage- und Gebrauchsanw eisung Deutsch English Français Instruc tions d’installa tion et d’utilisation Installation and Opera ting Instructions Bestell-Nr.
www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ ..................................................... .......... ...... E-2 1.1 Important Information ................. ...................
E-2 English 1 1 Please Read Immediately 1.1 Important Information ATTENTION! Any work on the heat pump may only be performed by authorised and qualified afte r-sales service techni cians. ATTENTION! The device is not suitable for ope ration with a frequency converter.
www.dimplex.de E-3 English 3.1 2 Purpose of the Heat Pump 2.1 Application The air-to-water heat pump is designed for use i n existing or newly built heating systems.
E-4 English 3.2 3.2 Switch Box The switch box is l ocated in the he at pump. All electr ical compo- nents are accessibl e after the front cover and the switch box cover have been removed. The switch box contain s the supply connecti on terminals, the plug connector for t he control line, as well as the power con tac- tors and the soft starter unit.
www.dimplex.de E-5 English 6.2 5S e t - u p 5.1 General Information The heat pump is suited for outdoo r installation . The device should always be in stalled on a permanently smooth, even and horizontal surfac e and must be aligned vert ically.
E-6 English 6.3 6.3 Electrical Connection A standard four-core cable i s use d for conn ecting the he at pump to the power s upply. The power supply and the control line are norma lly installed in the ground (in duct work with a suitable si ze and resistance) and routed from the heat pump t o the building.
www.dimplex.de E-7 English 8.2 Any faults occurri ng during operation a re also displayed on the heat pump contro ller and can be corrected as descri bed in the operating instructio ns of the heat pump controller.
E-8 English 8.3 8.3 Cleaning the Air System Evaporator, ventil ator and condensate outflow should be cleaned of contamination (le aves, twigs, etc.) before each new he ating period. Do this by opening the fro nt of the heat pump. The bottom should be opened firs t fo llowed by the top.
www.dimplex.de E-9 English 11 11 Device Information 1 Type and order code LA 17PS LA 22PS LA 26PS 2D e s i g n 2.1 Degree of protection according to EN 60 529 for compact devices and heating components IP 24 IP 24 IP 24 2.2 In stallation Lo cation Outdoors Outdoors Ou tdoors 3 Per formance data 3.
www.dimplex.de A-I Anhang · Ap pendix · Annex es Anhang / Appendix / Annexes 1 Maßbild / Dimension Drawing / Schéma coté ............................................................................ A-II 1.1 Maßbild / Dimension Drawing / Sc héma coté LA 17PS .
A-II Anhang · Ap pendix · Annex es 1 1 Maßbild / Dimension Drawing / Schéma coté 1.1 Maßbild / Dimension Draw ing / Schéma coté LA 17PS +HL]XQJVUFNODXI (LQJDQJLQGLH:3 ´ $XHQJHZLQGH +HL]XQJVYRUODXI $XVJDQJDXVGHU:3 ´ $XHQJHZLQGH .
www.dimplex.de A-III Anhang · Ap pendix · Annex es 1.2 1.2 Maßbild / Dimension Drawing / Schéma coté LA 22PS - LA 26PS +HL]XQJVUFNODXI (LQJDQJLQGLH:3 ´ $XHQJHZLQGH +HL]XQJVYRUODXI $XVJDQJDXVGHU:3 ´ $XHQJHZLQGH .
A-IV Anhang · Ap pendix · Annex es 2 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic Curv es / Courbes caractéristiques LA 17PS +HL]OHLVWXQJLQ>N:@ +HDWLQJFDSDFLWL.
www.dimplex.de A-V Anhang · Ap pendix · Annex es 2.2 2.2 Kennlinien / Characteristic Curv es / Courbes caractéristiques LA 22PS .
A-VI Anhang · Ap pendix · Annex es 2.3 2.3 Kennlinien / Characteristic Curv es / Courbes caractéristiques LA 26PS +HL]OHLVWXQJLQ>N:@ +HDWLQJFDSDFLWLQ>N:@ 3XLVVDQFHGHFKDXI.
www.dimplex.de A-VII Anhang · Ap pendix · Annex es 3.1 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande $OOH4XHUVFKQLWWHPP $OO.
A-VIII Anhang · Ap pendix · Annex es 3.2 3.2 Last / Load / Charge 8PLQ /LHIHU]XVWDQG< $VGHOLYHUHGVWDWH< (WDWjODOLYUDLVRQ<.
www.dimplex.de A-IX Anhang · Ap pendix · Annex es 3.3 3.3 Anschlussplan / Circuit Di agram / Schéma électrique 1HW]Â0DLQVÂ5pVHDX JHJQ HJQ MDYH 6WHXHUOHLWXQJÂ&am.
A-X Anhang · Ap pendix · Annex es 3.4 3.4 Legende / Legend / Légende E1 Ölsumpfheizung Verdichter 1 Oil sump heater for compressor 1 Chauffage à carter d’huile compres seur 1 E2 Ölsumpfheizung.
www.dimplex.de A-XI Anhang · Ap pendix · Annex es 4.1 4 Hydraulische Prinzipschemen / Hydraulic Plumbing Diagram / Schémas hydrauliques 4.1 Monoenergetische Anlage / Mono Energy System / Installati.
A-XII Anhang · Ap pendix · Annex es 4.2 4.2 Monoenergetische Anlage und Warmwasserbereit ung / Mono Energy System and Domestic Hot Water Preparatio n / Installation monoénergétique et production d.
www.dimplex.de A-XIII Anhang · Ap pendix · Annex es 4.3 4.3 Bivalente Anlage / Bivalent System / Installation bivalente.
A-XIV Anhang · Ap pendix · Annex es 4.4 4.4 Legende / Legend / Légende Absperrventil Shutoff valve Robinet d’arrêt Überstromventil Overflow valve Vanne de trop-plein Sicherheitsventi lkombinati.
www.dimplex.de A-XV Anhang · Ap pendix · Annex es 5 5 Konformitätserklärung / De claration of Conformity / Déclaration de conformité.
Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors.
An important point after buying a device Dimplex LA 17PS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dimplex LA 17PS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dimplex LA 17PS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dimplex LA 17PS you will learn all the available features of the product, as well as information on its operation. The information that you get Dimplex LA 17PS will certainly help you make a decision on the purchase.
If you already are a holder of Dimplex LA 17PS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dimplex LA 17PS.
However, one of the most important roles played by the user manual is to help in solving problems with Dimplex LA 17PS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dimplex LA 17PS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center