Table of Contents 13 sections Installation and Operating Instructions · Fan Heaters Model(s) : DXUF20T & DXUF30T · (IP20) · Dimensions (millimetres) · … ShowHide
Page 1 of the Dimplex DXUF20T user manual — Electrical connection
Page 1 · click to enlarge
Page 1

Installation and Operating Instructions

Fan Heaters Model(s) : DXUF20T & DXUF30T

(IP20)

Dimensions (millimetres)

H W D 236 242 175

(see Fig. 3)

Dimplex DXUF20T — H W D 236 242 175 diagram (page 1)
Fig. 1

(see Fig. 2)

Model (s) Specification

DXUF20T 2.0kW Thermostat & Switch

DXUF30T 3.0kW Thermostat & Switch

IMPORTANT SAFETY ADVICE

READ THESE INSTRUCTIONS BEFORE USE. DO NOT use the heater on deep pile carpets or the long hair type of rugs, or less than 750mm (30") away from any overhanging surface. Keep combustible materials such as drapes and other furnishings clear from the front, sides and rear of the heater. Do not use heater to dry your laundry.

BLUE : NEUTRAL BROWN : LIVE

DO NOT use the heater in the immediate surroundings of a bath, a shower or a swimming pool.

As the colours of the wires in the mains lead may not correspond with the coloured markings in your plug, proceed as follows : Connect the BROWN wire to the terminal marked ‘L’ or coloured RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK. Note : ‘L’ or ‘N’ must not be connected to the EARTH terminal marked ‘E’ or

DO NOT place the heater directly below a fixed socket outlet.

The socket-outlet must be accessible at all times to enable the mains plug to be disconnected as quickly as possible.

or coloured GREEN or GREEN AND YELLOW. If in doubt, consult your electrician.

DO NOT COVER or obstruct the air inlet and outlet openings in any way.

Using the Heater

The heater must be on a flat stable surface when in use.

Heat Control - see Fig. 2

DO NOT operate the heater with the mains lead overhanging the front outlet grille.

- OFF - Cool Blow* - Half heat - Full heat

NEVER leave the heater unattended when it is used by or near the aged, infirm person’s or children.

The heater carries the Warning symbol indicating that it must not be covered.

The instruction leaflet belongs to the appliance and must be kept in a safe place. If changing owners, the leaflet must be surrendered to the new owner.

Thermostat Control - see Fig. 3

The heat output is controlled by the thermostat, according to the room temperature. Turn the thermostat knob fully clockwise to maximum setting initially. When the room is warm enough, reduce the setting slowly until the heater just clicks off.

The heater will now cycle on and off to maintain your selected room temperature. An audible click may be heard when the thermostat operates - this is normal.

Electrical connection

This heater must be used on an A.C.~ supply only and the voltage marked on the heater must correspond to the supply voltage. This heater is fitted with a plug incorporating a 13 amp fuse. When replacing the fuse, a 13 amp fuse approved by ASTA to BS 1362 must be used. If the plug is not suitable for the socket outlets in your home, the plug must be cut off and an appropriate one fitted. A plug cut off from a mains lead will give a shock hazard if inserted into a 13 amp socket elsewhere in the house. To avoid this, it should be disposed of immediately.

* When the heat control is set to ‘ ‘ for cool blow, set the thermostat control to maximum.

Position ‘*‘ will turn the heater on and off to maintain a temperature of approximately 5°C.

08/35113/0 Issue 0 · *

Page 2 of the Dimplex DXUF20T user manual — Cleaning
Page 2 · click to enlarge
Page 2

Safety - overheat protection For your safety, this appliance is fitted with a thermal cut-out. In the event that the product overheats, the cut-out switches the heater off automatically. To bring the heater back into operation, remove the cause of overheating, then turn off the electrical supply to the heater for a few minutes. When the heater has cooled sufficiently reconnect and switch on the heater. If the cut-out operates repeatedly, contact your supplier.

After Sales Service

Your product is guaranteed for three years from the date of purchase.

Within this period, we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions.

Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee.

Should you require after sales service you should contact our customer services help desk on 0870 727 0101. It would assist us if you can quote the model number, series, date of purchase, and nature of the fault at the time of your call. The customer services help desk will also be able to advise you should you need to purchase any spares.

Recycling

For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.

Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service.

Please retain your receipt as proof of purchase.

Cleaning

WARNING ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER. Do not use detergents, abrasive cleaning powders or polish of any kind on the heater. Wipe with a dry cloth to remove dust and a damp cloth (not wet) to clean off stains. Be careful not to allow moisture into the heater. Ensure that dust or fluff does not accumulate inside the heater as this could lead to overheating of the element. Use a vacuum cleaner to remove any fluff which does accumulate.

The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336

Glen Dimplex UK Limited Millbrook House Grange Drive Hedge End Southampton Hampshire. SO30 2DF

UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)

Customer ServicesTel. 0870 7270101 Fax. 0870 7270102 e-mail customer.services@ glendimplex.com Republic of Ireland Tel. 01 8424833

[c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex DXUF20T

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex DXUF20T

Be the first to ask — other owners or our team will answer.

Original document

Dimplex DXUF20T manual PDF

2 pages·368 KB·Fan·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…