Installation and Operating Instructions

Dimplex Low Wattage Panel Heaters Models: DXLWP400, DXLWP400TI, DXLWP800, DXLWP800TI N & ARLWP800TI

600 mm - 400W

800 mm - 800W

Dimplex DXLWP400TI — Installation and Operating Instructions diagram (page 1)
Fig. 1 · Installation and Operating Instructions

DXLWP400 400W Neon Heat Switch

DXLWP400TI 400W Neon Heat Switch / 24 Hour Timer

DXLWP800 800W Neon Heat Switch

DXLWP800TI N 800W Neon Heat Switch / 24 Hour Timer

ARLWP800TI 800W 2 Neon Heat Switches / 24 Hour Timer

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Electrical Connection

Important Safety Advice

WARNING THIS APPLIANCE MUST BE EARTHED If the socket outlets in your home are not of the 13 amp BS1363 type they will not accept the plug connected to this heater, therefore cut off the plug. When cut off this plug can constitute a shock hazard if inserted into a socket outlet. It must therefore be disposed of safely. Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code.

SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.

GREEN/YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE Connect the Green/Yellow wire to the terminal marked E or the

The plug must be accessible after heater installation.

DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS ARE FITTED CORRECTLY.

earth symbol or coloured Green or Green/Yellow. Connect the Brown wire to the terminal marked L or coloured Red. Connect the Blue wire to the terminal marked N or coloured Black. DO NOT connect the Brown (Live) or the Blue (Neutral) wires to the Earth terminal of your 13 amp plug. If the terminals of the plug are unmarked or you are in any doubt, consult a qualified electrician. CAUTION: If you use this heater in conjunction with a thermal control, programme controller, timer or any other device which switches the heater on automatically observe all safety warnings at all times.

FOLLOW these instructions carefully.

The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally covered.

Models DXLWP400TI, DXLWP800TIN and ARLWP800TI can be set to switch on automatically. Remember to observe all safety warnings at all times.

This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.

If young children, the aged or infirm are likely to be left in the vicinity of the heater, we advise that adequate precautions should be taken. We recommend a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product.

If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

For further information, please contact our guard supplier direct on Tel. No. 01603 667957, or in case of difficulty or for further advice contact the Customer Helpline.

Show 4 more labels / short text on this page
INDUKLWPRG Issue 6 · Dimensions (millimetres) · Models Specification · 500 mm
Page 2 of the Dimplex DXLWP400TI user manual — Suggested Fixings
Page 2 · click to enlarge
Page 2

Positioning the Heater

130mm 340mm - 400W 540mm - 800W

Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below (wall mounted) and 25mm each side. Curtains must not be closer than 150mm from the top of the heater.

Free Standing Operation (see Fig. 1)

NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET FITTED (FEET ARE PACKED SEPARATELY IN CARTON).

1. Lay the heater on its front.
2. Remove the two socket head screws from the base of the heater using the hexagon key supplied.
3. Place feet over base of heater, align holes and engage hook on foot into the recess on the back of the heater - see Fig. 1 .
4. Replace the screws but do not overtighten.
3. Drill the wall at the three marked positions and fit the wall plugs.

Ensure template has been removed.

Dimplex DXLWP400TI — Positioning the Heater diagram (page 2)
Fig. 2 · Positioning the Heater
4. Fix two No. 8 screws to the top two holes leaving 3mm of the screw exposed. Hang the heater on the screws.
5. Fit the bottom bracket, found in the fixing kit, in the slot at the base of the heater and screw the bracket to the wall.

Test that the heater is now securely fixed to the wall.

Operation

Dimplex DXLWP400TI — Operation diagram (page 2)
Fig. 3 · Operation

OPERATION - SINGLE RATED MODELS

Models DXLWP400, DXLWP400TI, DXLWP800, and DXLWP800TI N Turn the heater on using the switch on the right side of the heater - the switch will be illuminated.

OPERATION - DUAL RATED MODEL - Model ARLWP800TI

The two switches on the side of the heater control the heat output. Both switches illuminated indicates maximum output. Top switch only illuminated indicates 500W output on 800W model. Bottom switch only illuminated indicates 300W output on 800W model. Note: on models fitted with a timer, at least one switch must be illuminated for the heater to operate.

Installation

The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3 Rawlplugs, 1 Mounting Bracket and 1 Hexagon Key.

MODELS WITH TIMER - (see Fig. 3)

Wall Mounted Operation (see Fig. 2)

DXLWP400TI and DXLWP800TI N - 1 Switch, The switch on the side of the heater turns the heater on. Note: This switch must be in the “on” position before the heater will operate. ARLWP800TI - 2 Switches The two switches on the side of the heater control the amount of heat available as described above, (Operation - Dual Rated Model). NOTE: At least one switch must be in the ‘On’ position before the heater will operate.

Suggested Fixings

SOLID BRICK/BLOCK: No. 8 Rawlplug inserts, 6mm drill bit. PLASTERBOARD: If possible locate studding and use No. 8 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.

1. Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below and 25mm each side. Curtains must not be closer than 150mm from the top of theheater. 2. Position the drilling template provided on the wall ensuring it is level. Mark the position of the relevant holes on the wall at the edge of template. Before drilling check that the distance between the hole centres is correct, 340mm for 400W Models and 540mm for 800W models (see Fig. 2).

Show 8 more labels / short text on this page
150mm · 130mm · 95mm · 420mm 25mm 25mm · Drilling Holes · Bracket · 50mm · Rear View
Page 3 of the Dimplex DXLWP400TI user manual — O
Page 3 · click to enlarge
Page 3

Models with Timer DXLWP400TI, DXLWP800TI N & ARLWP800TI

Set the I - ¡ - O slide switch on the timer (Fig. 3) to :

Position O - Heating Off

Position I - Manual operation This setting allows power to the heater uninterrupted by the timer settings. The heat selector switch will control the output (see ‘Using the heater’).

O

Position ¡ - ‘Auto’ operation

DO NOT disconnect this heater from the mains supply unless it is being taken out of use (e.g. in summer or for storage), otherwise the timer clock will stop.

Setting the time of day To set the time of day, rotate the timer dial clockwise (indicated by the arrow) until the correct time of day is opposite the reference mark (see Fig. 4). The 24-hour clock is used ; e.g. time shown for 3 pm is ‘15’ (15:00hrs).

O

Setting the ‘Auto’ ON and OFF times To set the timer :

1. Using your finger tip or the tip of a pencil, push in as many segments as necessary around the dial, according to the times you don’t require heat – see Fig. 4. Each segment pushed in switches the heater OFF for that part of the hour. All other segments will be ON. For example, Fig. 5 shows the timer set to switch the heater ON between 7 am and 9 am and between 4 pm and 9.30 pm . 2. You can select as many ON periods as you like, within the 24-hour day. The settings will repeat every day until changed. 3. To change ON and OFF times, simply push in any ‘ON’ segments you wish to cancel and pull out new ‘ON’ segments as required.

Dimplex DXLWP400TI — O diagram (page 3)
Fig. 4

Switching to auto Set the heat selector and thermostat for the heat output required.

Check that the clock shows the correct time of day. Set the I - ¡ - O slide switch to ¡ (see Fig. 4) - the convector will switch ON and OFF according to the timer settings (see Fig 5).

Page 4 of the Dimplex DXLWP400TI user manual — After Sales Service
Page 4 · click to enlarge
Page 4

Cleaning

WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER. Do not use detergents, abrasive cleaning powder or polish of any kind on the body of the heater. Allow the heater to cool, then wipe with a dry cloth to remove dust and a damp cloth (not wet) to clean off stains. Be careful not to allow moisture into the heater.

Recycling

For electrical products sold within the European Community.

At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.

After Sales Service

Your product is guaranteed for three years from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge (subject to availability) provided it has been installed and operated in accordance with these instructions. Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. Should you require after sales service you should contact our customer services help desk on 0870 727 0101. It would assist us if you can quote the model number, series, date of purchase, and nature of the fault at the time of your call. The customer services help desk will also be able to advise you should you need to purchase any spares. Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service. Please retain your receipt as proof of purchase.

The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336

Glen Dimplex UK Limited Millbrook House Grange Drive Hedge End Southampton Hampshire. SO30 2DF

UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)

Customer ServicesTel. 0870 7270101 Fax. 0870 7270102 e-mail customer.services@ glendimplex.com Republic of Ireland Tel. 01 8424833

[c] Glen Dimplex UK Limited

All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex DXLWP400TI

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex DXLWP400TI

Be the first to ask — other owners or our team will answer.

Original document

Dimplex DXLWP400TI manual PDF

4 pages·231 KB·Fan·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…