Instruction/ maintenance manual of the product A08184 DeWalt
Go to page of 26
INSTRUCTION MANUAL P ART NO. A08184 Rev . 0 Copyright © 2004 Delta Machinery T o lear n more about DEL T A MACHINER Y visit our website at: www .deltamachinery .
2- ENG A08184 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A08184 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG A08184 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A08184 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A08184 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
7- ENG A08184 Review and underst and all instructio ns and warnings in this manual. Become famil iar with the operation and contr ols of the air compresso r . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times .
8- ENG A08184 GLOSSAR Y DUTY CYCLE Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery .
9- ENG A08184 Assemble Wheels It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip. 1. Attach wheels with shoulder bolts and nuts as shown. 2. Tighten securely . NOTE : The outfit will sit level if the wheels are properly installed.
10- ENG A08184 INST ALLA TION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current.
11- ENG A08184 Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor , and to prevent overheating.
12- ENG A08184 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : T ur n this switch "ON/AUTO" to provide automatic power to the pressur e switch and "OFF" to remove power at the end of each use.
Before Starting Break-in instructions Serious damage may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
14- ENG A08184 How to Start: 1. T urn the On/Auto/Off lever to "ON/AUTO" and allow tank pressur e to build. Motor will stop when tank pressur e reaches "cut-out" pressur e. 2. T urn regulator knob clockwise to increase pressure and stop when desired pressur e is reached.
15- ENG A08184 NOTE: See "Operation" section for the location of controls. T o ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed.
16- ENG A08184 Air Compressor Pump Intake and Exhaust V alves Once a year have a T rained Service T echnician check the air compressor pump intake and exhaust valves. If it is dirty , replace it with a new filter . On some models,the filter may be removed by using a pair of needle nose pliers or a screwdriver .
17- ENG A08184 8. Apply sealant to the check valve threads. Reinstall the check valve (tur n clockwise). 9. Replace the pressur e release tube. Tighten nuts. 10. Replace the outlet tube and tighten nuts. 11. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.
18- ENG A08184 STORAGE Before you store the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "OFF".
19- ENG A08184 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e.
20- ENG A08184 PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section.
21- ENG A08184 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped.
22- ENG A08184 AIR COMPRESSOR DIAGRAM T orque 5-7 ft.-lbs. 5 24 26 27 28 25 9 10 21 15 17 6 10 11 14 18 4 3 T o rque 9-12 ft.-lbs. 2 1 T orque 15-25 ft.
23- ENG A08184 P ARTS LIST Key Part No. Number Description 1 ACG-408 Fastener Assembly (2) 2 AC-0376 Mini Shroud 3 91895680 Screw 1/4-20 x 3/4 (2) 4 ACG-18 Cup, Saddle Mount (2) 5 CAC-60 Shoulder Bolt.
24- ENG A08184 AIR COMPRESSOR PUMP DIAGRAM T orque 51-63 in.-lbs. T o rque 100-120 in.-lbs. T orque 100-120 in.-lbs. T o rque 7-10 ft.-lbs. T o rque 42-48 in.
25- ENG A08184 P ARTS LIST KEY P ART NO. NO. DESCRIPTION 70 SSF-586 Screw 1/4-20 x 3/4 72 AC-0108 Fan 73 SSF-615 Screw 1/4-20 UNC-2A THD 74 Z-AC-0107 Eccentric Bearing Assembly 76 Z-D27268 Motor 77 D2.
26- ENG A08184 A08184 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
An important point after buying a device DeWalt A08184 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought DeWalt A08184 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data DeWalt A08184 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, DeWalt A08184 you will learn all the available features of the product, as well as information on its operation. The information that you get DeWalt A08184 will certainly help you make a decision on the purchase.
If you already are a holder of DeWalt A08184, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime DeWalt A08184.
However, one of the most important roles played by the user manual is to help in solving problems with DeWalt A08184. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device DeWalt A08184 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center