
B-VENT DECORATIVE GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL

NATURAL GAS MODELS M36P(B,H), M42P(B,H), VM36P(B,H) AND VM42P(B,H)
PROPANE/LP GAS
FOR YOUR SAFETY — Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
fied installer, service agency or the gas supplier.
Save this manual for future reference. For more information, visit www.desatech.com

SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains infor- mation that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers.
This appliance may be installed in an aftermarket*, per- manently located, manufactured (mobile) home, where not prohibited by state or local codes.
This appliance is only for use with the type of gas indi- cated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
TABLE OF CONTENTS Safety Information 3 Unpacking 4 Introduction 4 Selecting Location 5 Product Specifications 6 Pre-Installation Preparation 7 Venting Installation 9 Installation 11 Operating Fireplace 19 Inspecting Burners 20
Cleaning and Maintenance 21 Wiring Diagram 22 Service Hints 22 Technical Service 22 Replacement Parts 22 Troubleshooting 23 Illustrated Parts Breakdown and Parts List 26 Accessories 31 Warranty Information Back Page

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. How- ever, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

Check all items for any shipping damage. If dam- aged, promptly inform dealer or distributor where you bought the product. Safely retain these items for later installation.
11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fire- place where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combus- tion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpeting, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replace- ment of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings.
INTRODUCTION Models M36(P)(B,H), VM36(P)(B,H), M42(P)(B,H) and VM42(P)(B,H) are vented gas fireplaces that use a millivolt gas control valve with a millivolt ignition system. A 6" B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 9 and 10.
Models M36(B,H), VM36(B,H), M42(B,H) and VM42(B,H) are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. A respective model PCBM-36 or PCBM-42 conversion kit may be purchased for simple conversion to propane/LP gas. See Accessories, page 31.
BEFORE YOU BEGIN Before beginning the installation of your appli- ance, read these instructions through completely. This DESA appliance and its approved compo- nents are safe when installed according to this installation manual and are operated as recom- mended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The DESA warranty will be voided by and DESA dis- claims any responsibility for the following actions : A) Modification of the appliance or any of the
components. B) Use of any component part not approved by
DESA in combination with this appliance. C) Installation and/or operation in a manner other
than instructed in this manual. D) The burning of anything other than the type of
gas approved for use in this gas appliance. The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes. This appliance complies with ANSI Z21.50-2000 and CSA 2.22-2000 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards.

SELECTING LOCATION To determine the safest and most efficient location for your appliance, you must take into consider- ation the following guidelines: 1. The location must allow for proper clearances (see Clearances, page 7). 2. Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 1 shows a plan view of a few common locations. Flush installations are recommended where living space is limited or at a premium and since the space required to enclose the appliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions. Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall. Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference. Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.
The appliance and itʼs individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas sup- ply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.
INTERNAL WALL INSTALLATION
FLUSH INSTALLATION
FULL PROJECTION INSTALLATION
Figure 1 - Possible Locations for
Installing Appliance


For Use With 6"Ø Type B-1 Vent Pipe Only
DIMENSIONS HEARTH AREA
H
D
B
G
13.5" 1.5" Glass Door (Optional)
Outside Air Kit Location (Optional)
O N
S T
R
W
P
Q
M

MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12" (229 mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fireplace opening.
B
1 1/2" (38mm) Max.
2 x 4 Stud
M42(B,H), M42P(B,H) VM42(B,H), VM42P(B,H)
A 14" (356 mm) 15" (381 mm)
B 8" (203 mm) 9" (229 mm)
Figure 5 - Mantel Clearances - Side View
Figure 3 - Minimum Clearances
1" (25mm) Min. Clearance to "B" Vent's Outer Pipe
42" (1067mm) Min. Clearance from Opening to Ceiling
Maintain 2" (51mm) Min. Clearance to the Transition Pipe as Measured at the Outer Vent Collar
*
Required Air Spaces are Indicated with an "*". Do Not Pack with Insulation or Any Other Material DO NOT BLOCK
OPENINGS 0" Clearance to Combustible or Noncombustible Flooring
Figure 6 - Side Clearances - Top View
Figure 4 - Minimum Clearances

PREPARATION
FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be raised above floor level, a platform must be built to support the appliance. 3. Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the appliance. The gas line must be installed through the lower left side ac- cess point or alternate access hole in the bottom of the appliance (see Figure 19, page 13). 4. Repack insulation around the gas line to cover any remaining openings in the conduit sleeve. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.
B
Figure 7 - Rough Opening for Installing
These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted
A
3/4" Clearance Not Required at Nailing Flanges
Figure 8 - Corner Installation Guidelines
in Wall

This appliance may be vented through a manufac- tured chimney system or a masonry chimney using a B-vent adapter or a chimney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10, page 10 are typical of most B-vent installations and codes practices. Example 1: Shows the minimum allowable sys- tem height and lateral offset for a 60° degree or greater inclination. Code specifies that offsets at 60° degrees or greater are considered horizontal and must follow the 75% percent rule for lateral to total vertical system height. Codes also allows only one offset in the total system when at 60° degrees or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% percent rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows a multiple offset each at 45° degrees of inclination. Multiple offsets are permit- ted if they do not exceed 45° degrees of inclination. The total lengths of the two offsets are not required to meet the 75% percent allowable rule. Example 3: Shows a single offset at 45° degrees of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% percent rule. In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceiling joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flash- ing, roof jack or a roof thimble. At all points the listed clearances must be maintained. Vent terminations must be located in accordance with height and proximity rules of NFPA No. 54 or CAN/CGA B149. These rules apply to vents at 12 in. diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 11, page 10). If venting horizontally through a side wall be- comes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing B-type vent systems if the system is at or above the recom- mended diameter of the flue; in this case 6". The flue connection must be made using listed
INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the fireplace, unattached and ready for installation. Remove the starter collar and set aside. Slide the transition pipe over the vent collar and attach with a minimum of three screws. Replace the starter collar over the transition pipe and attach using four screws located on the leg stands (five used on the model M42). To install B-vent piping, slide the first piece of B-vent over the transition pipe and attach with either a mini- mum of two screws or other means approved by the vent manufacturer.
Figure 9 - Installing Transition Pipe and
VENTING INSTALLATION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code ANSI Z223.1/NFPA 54 and in Canada with CAN/CGA B149 for Category I systems using double wall B-1 vent pipe. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burn- ing appliance.


Support Each Lateral At Least Every Six (6) Feet
Figure 10 - Typical B-Vent Configuration
B-type connectors and the existing system must be code inspected for damage and proper installation. It is not recommended that this appliance be com- mon vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in accordance with the common venting guides Appendix G of the current National Fuel Gas Code ANSI Z223.1/NFPA 54 and in Canada with CAN/CGA B149. Note: Before connecting this appliance to an existing vent system or a common venting sys- tem consult with your local architect, planner or building official.
8 Ft. Min.
x Listed Gas Vent
Roof Pitch x/12 Listed Clearance
H (Min) Height From Roof
Listed Vent Cap · Lowest Discharge Opening · Listed Vent Cap

INSTALLATION
WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve without the normal household electricity since the valve operates on millivolt current supplied by the heat generated by the thermopile. To install the wall switch: 1. Remove the front refractory access panel by lifting up and angling out of the firebox open- ing (see Figure 13). 2. Use wire and connectors provided. Attach red wire to terminal marked TH/TP on control valve. Attach white wire to blade connector on open end of safety circuit wiring (see Wiring Diagram, page 22). Note: If any of the original wire from the unit control must be replaced, use the same type or a higher rated wire (25 ft. maximum length).
CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of the fireplace opening and play it along the entire length of the opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance. If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.
Check this area along the entire top edge of the fireplace opening. Smoke or flame should be drawn into the appliance opening.
Figure 13 - Removing Front Refractory
Figure 12 - Checking for Spillage
Access Panel

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION Note: If using optional wireless hand-held remote control, the wall switch is no longer operational.
Installing Receiver 1. Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13, page 11) to expose controls. 2. Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14). 3. Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 15). 4. Connect wires to control circuit. Connect white wire to terminal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety cir- cuit wiring (see Wiring Diagram, page 22). 5. Locate the battery clip mounted on the back of the receiver (see Figure 16). 6. Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery. 7. Attach the terminal wires to the battery (see Figure 16). 8. Replace refractory brick access panel.
Figure 15 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)
Figure 16 - Installing Battery in Receiver
To Safety Circuit Route Millivolt
T
O
N
IN
P
F
TH TP THTP
F
O
IN OUT
Figure 14 - Wall Switch Wiring Diagram

DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 20) and into the appliance. Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 21, page 14). Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).
Installing 9-Volt Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing. Note: Only use alkaline battery. 3. Replace battery cover onto remote control unit.

Typical Exterior Wall Gas Shutoff Installation
Figure 17 - Installing Battery in Hand-
Held Remote Control Unit
Figure 18 - Manual Shutoff Valve

A manual shutoff valve has been included in the applianceʼs gas supply system. You may consider installing an extra gas shutoff valve outside the applianceʼs enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18. In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or sub-floor as shown in Figure 19.
A 8 5/8" (219 mm) 10 1/2" (267 mm)
Figure 19 - Routing Incoming Gas Line
Incoming 1/2" Gas Line Permitted by Local Codes Sediment Trap (Not Supplied)

Figure 20 - Sediment Trap

EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 22). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan mate- rial (see Figure 23). 4. Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 24, page 15).
WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a commercial leak detection solution to all con- nections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
Vermiculite (Pan Material) Burner Pan Grate
Figure 22 - Fill Entire Burner Pan with

Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVER- TIGHTEN.
Figure 23 - Ember Material on Surface of
Flexible Gas Line Do NOT Kink
Red Surface Indicates For Propane/LP Use Only

Figure 21 - Connecting Flexible Gas Line to Millivolt Valve


LOG PLACEMENT FOR M36, M36P, VM36 AND VM36P MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 25. 2. Place large back log (log 2) onto grate mak- ing sure notches rest over grate as shown in Figure 25. 3. Place log 3 into notch on log 2, resting the front end on top of log 1 (see Figure 26). 4. Place the upper end of log 4 into the notch on log 2 as shown in Figure 26. Rest the lower end of log 4 onto the middle grate finger as shown in Figure 27. 5. Place the upper end of log 5 into notch on the left of log 2 (see Figure 27). Rest the lower end of log 5 on the grate as shown in Figure 28. 6. Insert the lower end of log 6 between the first two grate fingers as shown in Figure 28 and position the upper end of log 6 into the notched area on the front of log 2 as shown in Figure 28. As an option to enhance the look of the hearth, you may place the lava rock provided around the front and sides of the burner.
Figure 26 - Installing Logs 3 and 4


Figure 27 - Installing Logs 5 and 6

VM36 and VM36P Models
Figure 25 - Installing Logs 1 and 2

5. Place the upper end of log 5 into the notch on the top inner right of log 1 (see Figure 31). Rest the lower end of log 5 on the middle grate finger as shown in Figure 32. 6. Place log 6 into the notch on the top right of log 1 (see Figure 31). Rest the lower end of log 6 on top of log 2B (see Figure 32). As an option to enhance the look of the hearth, you may place the lava rock provided around the front and sides of the burner pan.
LOG PLACEMENT FOR M42, M42P, VM42 AND VM42P MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 29). 2. Insert lower end of log 2A between the first two grate fingers and position the upper end into the notch on the front of log 1. See Figure 29. Place log 2B on the front right side of grate as shown in Figure 29. 3. Place log 3 into notch on top left of log 1, rest- ing the lower end on the left two grate fingers (see Figure 30). 4. Place the upper end of log 4 into the notch on log 1 as shown in Figure 30. Rest the lower end of log 4 on the middle grate finger as shown in Figure 31.


Figure 31 - Installing Logs 5 and 6
Figure 29 - Installing Logs 1, 2A and 2B


Figure 32 - Logs Installed for M42, M42P,
VM42 and VM42P Models
Figure 30 - Installing Logs 3 and 4

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 33). Pull the handle to open or push to close.
Note: Glass door may be heavy for some individu- als. If this is the case, please request help from someone else. The M36, VM36, M42 and VM42 B-vent fire- places are approved for use with optional bi-fold glass doors (see Accessories, page 31). The glass panels may be ordered and installed anytime after the fireplace installation is complete. Follow these steps to install left and right panels: 1. With the handle at the bottom, completely fold the panel on its hinges. 2. With the handle facing the center of the firebox opening, insert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 35). 3. Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the firebox opening. 4. Tilt the glass assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 35). 5. Once the top and bottom pins are secured, unfold the door into the closed position.
Figure 33 - Air Kit Handle Location
APPLIANCE ENCLOSURE Before finishing the enclosure around the appli- ance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking. If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance (see Figure 34).
Insert Pin Into Spring Clip
Slide Top Pin Into Door Track
Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position
Caulk Here Pack Insulation
Figure 34 - Sealing Between Appliance
Figure 35 - Installing Optional Glass

Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track
6. Repeat the process for the opposite door assembly. 7. To adjust the doors, slide them partially open. Using a screwdriver, loosen the hold-down screws in the spring clip (see Figure 36) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face. 9. Reopen one door at a time and retighten the upper and lower hold-down screws. 10. Repeat the process until both doors are evenly joined, spaced and working freely.
Depress Spring Clip to Release Pivot Pin
Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track
Figure 37 - Removing Glass Doors
OPENING VENT DAMPER Vent damper must be locked in the full open posi- tion before operating the fireplace. If vent damper is not open, fireplace will not light.
The doors may be removed for replacement or cleaning as follows: 1. Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip. 2. Fully fold the frame assembly and slide the upper edge towards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 37).
CLOSE OPEN
IN THE FULL OPEN POSITION TO OPERATE THE APPLIANCE
Figure 38 - Opening Vent Damper
Figure 36 - Adjusting Glass Doors

1. STOP! Read the safety information, column 1. 2. Turn wall switch to the OFF position. 3. Turn off all electric power to the appliance. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel. 6. Turn gas control knob clockwise to the OFF position (see Figure 39). 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you donʼt smell gas, go to the next step.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has
been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
ON
IN
O
T
P
OFF
Figure 39 - Control Knob in the PILOT

TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
Figure 41 - On/Off Hand-Held Remote
INSPECTING BURNERS Check pilot flame pattern and burner flame pat- terns often.
Figure 40 - Pilot
REMOTE OPERATION Note: The receiver and hand-held remote control kit must be purchased separately (see Accessories, page 31). Follow installation in- structions on page 10 of this manual. 1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery. 2. Press the control button on the hand-held remote to turn the burner on. Press the control button again to turn burner off (see Figure 41).

CLEANING AND
MAINTENANCE


WARNING: Installation and repair should be done by a quali- fied service person. The appli- ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys- tem be kept clean.
Figure 42 - Correct Pilot Flame Pattern

Figure 43 - Typical Flame Pattern
Thermopile · Pilot Burner · Ignitor

THERMOPILE
IGNITOR
REPLACE FACTORY WIRING WITH 105°C EQUIVALENT OR HIGHER RATING
THERMOSTAT WIRE 18 GA. RED/WHITE EXTERNAL WIRING USE ONLY CLASS 2
DO NOT CONNECT RED
TO 120V
WHITE
N.O. SW
N.C.SW
T
O
N
TH
P
O
TP
MANUAL DAMPER SWITCH
F
F
O
MAIN GAS INCOMING
TH/TP
(VENT SAFETY SHUTOFF SWITCH)
SUPPLY
PILOT SAFETY WIRE
WALL SWITCH
(SUPPLIED)
SERVICE HINTS
REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
TECHNICAL SERVICE You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESAʼs Technical Services web site at www.desatech.com.

TROUBLESHOOTING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Pilot will not light
1. Check to see if you have gas supply 2. Hold regulator control valve in the PILOT position for 2 to 3 minutes to purge air. If you smell gas stop and wait for a few minutes before trying to light the fireplace 3. Remove debris and dirt, in- spect and clean any other possible obstructions 4. Contact your gas supplier 5. Refer to section on pilot lighting 6. Have a qualified technician replace pilot line 7. Replace regulator valve (see Accessories, page 31) 8. Open vent damper until fully locked in OPEN position
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position
Frequent pilot outage

POSSIBLE CAUSE
REMEDY
Pilot goes out when wall switch is ON
Spark ignitor will not light pilot after repeated triggering of red button
1. Check for spark at the elec- trode and pilot; if no spark and electrode wire is properly connected, replace ignitor 2. Using a match, light pilot. If pilot lights, turn off pilot and trigger the red button again. If pilot lights, an improper gas/air mixture caused the improper lighting and a longer purge period is recommended. If pilot will not light, check gap at electrode and pilot. Gap should be 1/8" to have a strong spark. If okay, replace pilot 3. A) Check remote shut off valves from fireplace. Usually there is a valve near the fire- place and sometimes there is a valve near the main. There can be more than one (1) valve be- tween the fireplace and main B) Low pressure can be caused by a variety of situations such as bent line, or gas supplier 4. Check propane/LP supply and contact local propane/LP supplier
Fireplace produces a clicking/ ticking noise just after burner is lit or shut off

POSSIBLE CAUSE
REMEDY
Fireplace produces unwanted odors
odor causing products while fireplace is running
Gas odor even when control knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace



PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual.
KEY NO.
M42(B,H) VM42(B,H) DESCRIPTION QTY 1 14153 14153 Micro Switch 1 2 ** ** Insulation Pan 1 3 ** ** Fireplace Top Assembly
KEY NO.
M42(B,H) VM42(B,H) DESCRIPTION QTY 35 901064-03 901064-08 Orifice (NG) 1 901065-13 901065-12 Orifice (LP) 1 36 108084-01 108084-01 Pilot (NG) 1 108084-03 108084-03 Pilot (LP) 1 37 108085-01 108085-01 Pilot Orifice (NG)
4 ** ** Fireplace Surround
5 106642-01 106642-01 Air Rod Retainer
108085-02 108085-02 Pilot Orifice (LP)
6 106643-01 106643-01 Damper Rod Retainer
38 11102 11102 Screw, #8- 32 x 3/8
7 106651-01 107805-01 Panel Closure 2 8 ** ** Firebox Bottom
39 14512 14512 Gas Control Valve (NG)
14513 14513 Gas Control Valve (LP)
9 ** ** Firebox Surround
40 107741-01 107741-01 Valve Bracket 1 41 14261 14261 Piezo Ignitor 1 42 111288-02 111288-02 Manual Valve w/ Flex Hose
10 106657-02 107811-02 Air Separator 1 11 11408 11408 Bushing 2 12 See page 28 Left Refractory 1 13 See page 28 Right Refractory 1 14 See page 28 Rear Refractory 1 15 See page 28 Bottom Rear Refractory
43 108769-01 108769-02 Extension Deflector
44 108005-01 108005-01 Wire Harness 1 45 108005-02 108005-02 Wire Harness 1 46 11418 11418 Push-On Nut 2 47 12105 107840-01 Screen 2 48 14123 14123 Strain Relief 1 49 14574 106543-01 Limit Switch 1 50 ** ** Collar Insulation
16 See page 28 Bottom Front Refractory
17 ** ** Firebox Support Leg
18 106687-01 106887-02 Damper Can Collar
19 106691-01 107839-01 Screen Rod 2 20 ** ** Firebox Top Assembly
51 20023 20488 Starter Collar 1 52 20027 20027 Brick Liner Retainer
21 106699-01 106699-01 Transition 6" B-Vent Collar
53 20042 20042 Air Kit Cover 1 54 20088 20088 Door Stop 1 55 20089 20089 Pivot Clip 2 56 20090 20090 Spring Clip 2 57 20280 20280 Top Spacer 4 58 ** ** Gas Knockout Cover
22 106703-01 106703-01 Air Kit Door Assembly
23 ** ** Firebox Face 1 24 106948-02 107823-02 Smoke Deflector
25 ** ** Fireplace Top Insulation
59 ** ** Gas Conduit 1 60 ** — Gas Conduit 1 61 22912 22924 Draft Diverter 1 62 24353 24353 Box Assembly 1 63 11165 11165 Screw, #10 x 5/8 Mod. Tr. Blk. Ox
26 107796-01 107796-02 Grate Assembly
27 107742-01 107742-02 Burner Pan 1 28 107795-01 107831-01 Burner Tube 1 29 107748-01 107748-01 Burner Bracket
30 107985-01 107985-02 Pilot Shield 1 31 901681-01 901681-01 Burner Clamp 1 32 11209 11209 Nut, #10-24 1 33 11147 11147 Screw, #10- 24 x 1/2
PARTS AVAILABLE NOT SHOWN 901155-01 901155-01 Vermiculite Bag
901156-01 901156-01 Pan Material 1 901157-01 901157-01 Lava Rock 1 22180 22180 Wall Switch Kit
34 901066-01 901066-01 Brass Air Mixer (NG)
901066-02 901066-02 Brass Air Mixer (LP)
** Not a field replaceable part.


KEY NO.
M42(B,H) VM42(B,H) DESCRIPTION QTY 12 106658-02 107812-02 Left Refractory, Std. Brick (M36B/M42B) 1 108164-02 108169-02 Left Refractory, Herringbone (M36H/M42H) 1 106658-01 107812-01 Left Refractory, Std. Brick (VM36B/VM42B) 1 108164-01 108169-01 Left Refractory, Herringbone (VM36H/VM42H) 1 13 106659-02 107814-02 Right Refractory, Std. Brick (M36B/M42B) 1 108165-02 108170-02 Right Refractory, Herringbone (M36H/M42H) 1 106659-01 107814-01 Right Refractory, Std. Brick (VM36B/VM42B) 1 108165-01 108170-01 Right Refractory, Herringbone (VM36H/VM42H) 1 14 106660-02 107816-02 Rear Refractory, Std. Brick (M36B/M42B) 1 108166-02 108171-02 Rear Refractory, Herringbone (M36H/M42H) 1 106660-01 107816-01 Rear Refractory, Std. Brick (VM36B/VM42B) 1 108166-01 108171-01 Rear Refractory, Herringbone (VM36H/VM42H) 1 15 106661-02 107818-02 Bottom Rear Refractory, Std. Brick (M36/M42, M36B/M42B) 1 108167-02 108172-02 Bottom Rear Refractory, Herringbone (M36H/M42H) 1 106661-01 107818-01 Bottom Rear Refractory, Std. Brick (VM36/VM42, VM36B/VM42B)
108167-01 108172-01 Bottom Rear Refractory, Herringbone (VM36H/VM42H) 1 16 106662-02 107820-02 Bottom Front Refractory, Std. Brick (M36/M42, M36B/M42B)
108168-02 108173-02 Bottom Front Refractory, Herringbone (M36H/M42H) 1 106662-01 107820-01 Bottom Front Refractory, Std. Brick (VM36/VM42, VM36B/VM42B)
108168-01 108173-01 Bottom Front Refractory, Herringbone (VM36H/VM42H) 1


3 108720-01 Top Right Log - 11 3/4" 1
5 108722-01 Top Left Log - 13 1/2" Y-Log 1


2B 108839-01 Right Front Log - 15 3/4" Round 1
3 108722-01 Top Left Log - 13 1/2" Y-Log 1
4 108838-01 Inside Top Left Log - 15 3/4" Split 1
5 108721-01 Inside Top Right Log - 16" 1
6 108720-01 Top Right Log - 11 3/4" 1

ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESAʼs Sales Department at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.
AIR KIT - AK4 Optional kit helps offset the negative pressure of- ten existing in today's tightly constructed homes.
BLOWER KIT BK - Squirrel Cage Blower With Speed Control BK3E - Triple Fan Blower System
REMOTE CONTROL KITS RC - Standard On/Off Millivolt Remote Control Kit HRC100 - Hand-Held Remote Control Kit GWMT1 - Wall-Mount Remote Control Kit
PERIMETER TRIM PT36 - 36" Perimeter Trim - Black PT36B - 36" Perimeter Trim - Brushed Brass PT36PB - 36" Perimeter Trim - Polished Brass PT36P - 36" Perimeter Trim - Platinum PT42 - 42" Perimeter Trim - Black PT42B - 42" Perimeter Trim - Brushed Brass PT42PB - 42" Perimeter Trim - Polished Brass PT42P - 42" Perimeter Trim - Platinum
PROPANE CONVERSION KITS PCBM-36 - Propane Conversion Kit for 36" B- Vent Millivolt Fireplace PCBM-42 - Propane Conversion Kit for 42" B- Vent Millivolt Fireplace
LOUVER TRIM (Rolled Louvers Only) LT36B - 36" Louver Trim Kit - Brushed Brass LT36P - 36" Louver Trim Kit - Platinum LT36PB - 36" Louver Trim Kit for VM36(B,H) - Polished Brass LT42B - 42" Louver Trim Kit - Brushed Brass LT42P - 42" Louver Trim Kit - Platinum LT42PB - 42" Louver Trim Kit for VM42(B,H) - Polished Brass
EXTRUDED ALUMINUM BI-FOLD GLASS DOORS BD36 - 36" Black Finish BD36B - 36" Brushed Brass Finish BD36P - 36" Platinum Finish BD42 - 42" Black Finish BD42B - 42" Brushed Brass Finish BD42P - 42" Platinum Finish
BRICK LINER (For M36(B,H), M36P(B,H), M42(B,H) and M42P(B,H) BL36 - 36" Refractory Standard Brick Liner Kit BL42 - 42" Refractory Standard Brick Liner Kit BL36H - 36" Refractory Herringbone Brick Liner Kit BL42H - 42" Refractory Herringbone Brick Liner Kit
FACE/LOUVER PANEL KITS SP36, SP42 - Smooth Faced Panel Kit- Black SL36, SL42 - Stamped Louver Panel Kit- Black RL36, RL42 - Rolled Louver Kit- Black FP36, FP42 - Filigree Panel Kit- Black FP36B, FP42B - Filigree Panel Kit- Brushed Brass FP36P, FP42P - Filigree Panel Kit- Platinum FP36PB, FP42PB - Filigree Panel Kit- Polished Brass
(For VM36(B,H), VM36P(B,H), VM42(B,H) and VM42P(B,H) BL36S - 36" Refractory Standard Brick Liner Kit BL42S - 42" Refractory Standard Brick Liner Kit BL36HS - 36" Refractory Herringbone Brick Liner Kit BL42HS - 42" Refractory Herringbone Brick Liner Kit
FIRE CRACKLE - CF6-A Creates the sound of a real burning fire.

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this war- ranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESAʼS LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI- DENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
108795-01 Rev. N 04/05 NOT A UPC
Model · Date Purchased · 108795 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.