MODELS M36(B,H), M42(B,H), VM36(B,H) AND VM42(B,H) NATURAL GAS MODELS M36P(B,H), M42P(B,H), VM36P(B,H) AND VM42P(B,H) PROPANE/LP GAS
SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other im- portant papers.
FOR YOUR SAFETY — Do not store or use gasoline or any other flam-
mable vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
CHECK LOCAL CODES PRIOR TO
INSTALLATION
MASSACHUSETTS STATE CODE RE- QUIRES THE VENT DAMPER TO BE WELDED OPEN OR REMOVED.
a qualified installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Save this manual for future reference.



Models M36(P)(B,H), VM36(P)(B,H), M42(P)(B,H) and VM42(P)(B,H) are vented gas fireplaces that use a millivolt gas control valve with a millivolt ignition system. A 6" B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 9 and 10.
9. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 18. 11. Keep the area around your fireplace clear of combustible ma- terials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpeting, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert or other ac- cessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings. UNPACKING
Models M36(B,H), VM36(B,H), M42(B,H) and VM42(B,H) are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. A respective model PCBM-36 or PCBM-42 conversion kit may be purchased for simple conversion to propane/LP gas. See Accessories, page 27.
BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This DESA appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved com- ponents tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions : A) Modification of the appliance or any of the components. B) Use of any component part not approved by DESA in combina-
tion with this appliance. C) Installation and/or operation in a manner other than instructed
in this manual. D) The burning of anything other than the type of gas approved
for use in this gas appliance. The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes. This appliance complies with ANSI Z21.50-2000 and CSA 2.22-2000 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards.


The appliance and itʼs individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.
For Use With 6"Ø Type B-1 Vent Pipe Only
DIMENSIONS HEARTH AREA
H
D
B
G
13.5" 1.5" Glass Door (Optional)
Outside Air Kit Location (Optional)
O N
R
S T
W
P
Q
M
Figure 1 - Appliance Dimensions


PRE-INSTALLATION PREPARATION
To determine the safest and most efficient location for your appli- ance, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Clearances, next column). 2. Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a plan view of a few common locations. Flush installations are recommended where living space is limited or at a premium and since the space required to enclose the appliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions. Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, fin- ished wall. Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference. Internal wall installations provide a discreet option for room sepa- ration and can also be ideal as an addition to an existing wall.


1" (25mm) Min. Clearance to "B" Vent's Outer Pipe
Maintain 2" (51mm) Min. Clearance to the Transition Pipe as Measured at the Outer Vent Collar
Required Air Spaces are Indicated with an "*". Do Not Pack with Insulation or Any Other Material DO NOT BLOCK


MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12" (229 mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle compo- nents in relation to the fireplace opening.


1 1/2" (38 mm) Max. 3" (76 mm) Max.
Figure 6 - Side Clearances - Top View (Cross Section)
Figure 5 - Mantel Clearances - Side View (Cross Section)


These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted

FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be raised above floor level, a platform must be built to support the appliance. 3. Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the ap- pliance. The gas line must be installed through the lower left side access point or alternate access hole in the bottom of the appliance (see Figure 19, page 11). 4. Repack insulation around the gas line to cover any remaining openings in the conduit sleeve. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.
A 24 1/2" (622.3 mm) 27 9/16" (700.1 mm)
B 73 7/8" (1876.4 mm) 83 7/8" (2130.4 mm)
C 52 3/16" (1326 mm) 59 5/16" (1506.6 mm)
D 17 1/4" (438.2 mm) 19 1/2" (495.3 mm)
Figure 8 - Corner Installation Guidelines
INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the fireplace, unattached and ready for installation. Remove the starter collar and set aside. Slide the transition pipe over the vent collar and attach with a minimum of three screws. Replace the starter collar over the transition pipe and attach using four screws located on the leg stands (five used on the model M42). To install B-vent piping, slide the first piece of B-vent over the transition pipe and attach with either a minimum of two screws or other means approved by the vent manufacturer.


A 40 3/8" (1020 mm) 44 3/8" (1121 mm)
B 21 3/8" (543 mm) 23 1/8" (587 mm)
C 41 1/4" (1048 mm) 48 1/4" (1226 mm)
Figure 9 - Installing Transition Pipe and Starter Collar
Figure 7 - Rough Opening for Installing in Wall


Example 1: Shows the minimum allowable system height and lateral offset for a 60° degree or greater inclination. Code specifies that offsets at 60° degrees or greater are considered horizontal and must follow the 75% percent rule for lateral to total vertical system height. Codes also allows only one offset in the total system when at 60° degrees or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% percent rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows a multiple offset each at 45° degrees of inclina- tion. Multiple offsets are permitted if they do not exceed 45° degrees of inclination. The total lengths of the two offsets are not required to meet the 75% percent allowable rule. Example 3: Shows a single offset at 45° degrees of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% percent rule. In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceiling joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained.
A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local build- ing codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code ANSI Z223.1/NFPA 54 and in Canada with CAN/CGA B149 for Category I systems using double wall B-1 vent pipe. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance. This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chimney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10 are typical of most B-vent instal- lations and codes practices.

Support Each Lateral At Least Every Six (6) Feet
Figure 10 - Typical B-Vent Configuration
Listed Vent Cap


Vent terminations must be located in accordance with height and proximity rules of NFPA No. 54 or CAN/CGA B149. These rules apply to vents at 12 in. diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 11). If venting horizontally through a side wall becomes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing B-type vent systems if the system is at or above the recommended diameter of the flue; in this case 6". The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation. It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in accordance with the common venting guides Appendix G of the current National Fuel Gas Code ANSI Z223.1/NFPA 54 and in Canada with CAN/CGA B149. Note: Before connecting this appliance to an existing vent system or a common venting system consult with your local architect, planner or building official.
CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of the fireplace opening and play it along the entire length of the opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance. If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.

Check this area along the entire top edge of the fireplace opening. Smoke or flame should be drawn into the appliance opening.


Roof Pitch H (Min.) Ft. m Flat to 6/12 1.0 0.30 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.0 1.22 Over 12/12 to 14/12 5.0 1.52 Over 14/12 to 16/12 6.0 1.83 Over 16/12 to 18/12 7.0 2.13 Over 18/12 to 20/12 7.5 2.27 Over 20/12 to 21/12 8.0 2.44
Figure 12 - Checking for Spillage
Figure 11 - B-Vent Terminations


4. Connect wires to control circuit. Connect white wire to termi- nal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety circuit wiring (see Wiring Diagram, page 18). 5. Locate the battery clip mounted on the back of the receiver (see Figure 16). 6. Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery. 7. Attach the terminal wires to the battery (see Figure 16). 8. Replace refractory brick access panel.
WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve without the normal household electricity since the valve operates on millivolt current supplied by the heat generated by the thermopile. To install the wall switch: 1. Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13). 2. Use wire and connectors provided. Attach red wire to terminal marked TH/TP on control valve. Attach white wire to blade connector on open end of safety circuit wiring (see Wiring Diagram, page 18). Note: If any of the original wire from the unit control must be re- placed, use the same type or a higher rated wire (25 ft. maximum length).
To Safety Circuit Route Millivolt


Figure 14 - Wall Switch Wiring Diagram
Figure 15 - Installing Remote Receiver (Shown from Rear of
Figure 16 - Installing Battery
Installing 9-Volt Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to the battery (not included). Place battery into the battery housing. Note: Only use alkaline battery. 3. Replace battery cover onto remote control unit.
Figure 13 - Removing Front Refractory Access Panel
OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION Note: If using optional wireless hand-held remote control, the wall switch is no longer operational. Installing Receiver 1. Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13) to expose controls. 2. Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14). 3. Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 15).

Figure 17 - Installing Battery in Hand-Held Remote Control Unit


Typical Exterior Wall Gas Shutoff Installation

Figure 18 - Manual Shutoff Valve Installation
A manual shutoff valve has been included in the applianceʼs gas supply system. You may consider installing an extra gas shutoff valve outside the applianceʼs enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18. In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or sub-floor as shown in Figure 19.

DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 20) and into the appliance. Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 21). Before connecting the black iron gas line to the inside of the appli- ance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).
A 8 5/8" (219 mm) 10 1/2" (267 mm)
Figure 19 - Routing Incoming Gas Line

Sediment Trap (Not Supplied)
Figure 20 - Sediment Trap
WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a com- mercial leak detection solution to all connections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
Red Surface Indicates For Propane/LP Use Only

Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.
Figure 21 - Connecting Flexible Gas Line to Millivolt Valve


LOG PLACEMENT FOR M36, M36P, VM36 AND VM36P MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 25. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 25. 3. Place log 3 into notch on log 2, resting the front end on top of log 1 (see Figure 26). 4. Place the upper end of log 4 into the notch on log 2 as shown in Figure 26. Rest the lower end of log 4 onto the middle grate finger as shown in Figure 27.
EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 22). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan material (see Figure 23). 4. Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 24).


Figure 22 - Fill Entire Burner Pan with Vermiculite
Ember Material Burner Pan Vermiculite (Pan Material) Grate

Figure 25 - Installing Logs 1 and 2

Figure 23 - Ember Material on Surface of Pan Material

Figure 24 - Pan and Ember Material Clearances
Figure 26 - Installing Logs 3 and 4


LOG PLACEMENT FOR M42, M42P, VM42 AND VM42P MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 29). 2. Insert lower end of log 2A between the first two grate fingers and position the upper end into the notch on the front of log 1. See Figure 29. Place log 2B on the front right side of grate as shown in Figure 29. 3. Place log 3 into notch on top left of log 1, resting the lower end on the left two grate fingers (see Figure 30). 4. Place the upper end of log 4 into the notch on log 1 as shown in Figure 30. Rest the lower end of log 4 on the middle grate finger as shown in Figure 31.
5. Place the upper end of log 5 into notch on the left of log 2 (see Figure 27). Rest the lower end of log 5 on the grate as shown in Figure 28. 6. Insert the lower end of log 6 between the first two grate fingers as shown in Figure 28 and position the upper end of log 6 into the notched area on the front of log 2 as shown in Figure 28. As an option to enhance the look of the hearth, you may place the lava rock provided around the front and sides of the burner.


Figure 27 - Installing Logs 5 and 6
Figure 29 - Installing Logs 1, 2A and 2B


Figure 28 - Logs Installed for M36, M36P, VM36 and VM36P Models
Figure 30 - Installing Logs 3 and 4
Notch · Log 2A · Log 2B


COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 33). Pull the handle to open or push to close.
5. Place the upper end of log 5 into the notch on the top inner right of log 1 (see Figure 31). Rest the lower end of log 5 on the middle grate finger as shown in Figure 32. 6. Place log 6 into the notch on the top right of log 1 (see Figure 31). Rest the lower end of log 6 on top of log 2B (see Figure 32). As an option to enhance the look of the hearth, you may place the lava rock provided around the front and sides of the burner pan.


Figure 33 - Air Kit Handle Location
APPLIANCE ENCLOSURE Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking. If the appliance is mounted on a raised platform, it must be a con- tinuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance (see Figure 34).
Figure 31 - Installing Logs 5 and 6

Figure 32 - Logs Installed for M42, M42P, VM42 and VM42P Models
Caulk Here Pack Insulation
Figure 34 - Sealing Between Appliance and Framing


The doors may be removed for replacement or cleaning as follows: 1. Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip. 2. Fully fold the frame assembly and slide the upper edge towards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 37).
Note: Glass door may be heavy for some individuals. If this is the case, please request help from someone else. The M36, VM36, M42 and VM42 B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 27). The glass panels may be ordered and installed anytime after the fireplace installation is complete. Follow these steps to install left and right panels: 1. With the handle at the bottom, completely fold the panel on its hinges. 2. With the handle facing the center of the firebox opening, insert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 35). 3. Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the firebox opening. 4. Tilt the glass assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 35). 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly. 7. To adjust the doors, slide them partially open. Using a screw- driver, loosen the hold-down screws in the spring clip (see Figure 36) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face. 9. Reopen one door at a time and retighten the upper and lower hold-down screws. 10. Repeat the process until both doors are evenly joined, spaced and working freely.

Figure 36 - Adjusting Glass Doors

Depress Spring Clip to Release Pivot Pin
Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track
Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track

OPENING VENT DAMPER Vent damper must be locked in the full open position before operating the fireplace. If vent damper is not open, fireplace will not light.
Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position
IN THE FULL OPEN POSITION TO OPERATE THE APPLIANCE
Spring Clip · Pivot Plate



A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area

Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water.
Figure 39 - Control Knob in the PILOT position Position Indicator
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn gas control knob clockwise to “OFF”. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.

1. STOP! Read the safety information, above. 2. Turn wall switch to the OFF position. 3. Turn off all electric power to the appliance. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel. 6. Turn gas control knob clockwise to the OFF position (see Figure 39). 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you donʼt smell gas, go to the next step. 8. Turn control knob counterclockwise to the PILOT position.

Figure 40 - Pilot
Gas Control Knob · Pilot Adjustment Screw · Ignitor


OPERATING FIREPLACE Continued
Check pilot flame pattern and burner flame patterns often.
REMOTE OPERATION Note: The receiver and hand-held remote control kit must be purchased separately (see Accessories, page 27). Follow instal- lation instructions on page 10 of this manual. 1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery. 2. Press the control button on the hand-held remote to turn the burner on. Press the control button again to turn burner off (see Figure 41). 3. To Lock press both buttons on remote control until light stops flashing. Remote is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. 4. To Unlock press both buttons together on remote control until light stops flashing. The remote is now unlocked.
Control Button Turns Burners On and Off
Figure 42 - Correct Pilot Flame Pattern
Figure 41 - On/Off Hand-Held Remote Control Unit GHRCB

Figure 43 - Typical Flame Pattern
Thermopile · Pilot Burner · Ignitor


SERVICE HINTS

WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, pet hair, etc. It is imperative that the control compartments, burners and circulating air system be kept clean.
You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Technical Service Depart- ment at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESAʼs Technical Services web site at www.desatech.com. REPLACEMENT PARTS

REPLACE FACTORY WIRING WITH 105°C EQUIVALENT OR HIGHER RATING
THERMOSTAT WIRE 18 GA. RED/WHITE EXTERNAL WIRING USE ONLY CLASS 2
(SUPPLIED)


POSSIBLE CAUSE
REMEDY
Pilot will not light
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position
Pilot goes out when wall switch is ON
Frequent pilot outage


POSSIBLE CAUSE
REMEDY
Spark ignitor will not light pilot after re- peated triggering of red button
1. Check for spark at the electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor 2. Using a match, light pilot. If pilot lights, turn off pilot and trigger the red button again. If pilot lights, an improper gas/air mixture caused the improper lighting and a longer purge period is recom- mended. If pilot will not light, check gap at electrode and pilot. Gap should be 1/8" to have a strong spark. If okay, replace pilot 3. A) Check remote shut off valves from fireplace. Usually there is a valve near the fireplace and sometimes there is a valve near the main. There can be more than one (1) valve between the fireplace and main B) Low pressure can be caused by a va- riety of situations such as bent line, too narrow diameter of pipe or even low line pressure. Check for kinked lines. If none, consult with plumber or gas supplier 4. Check propane/LP supply and contact local propane/LP supplier
Fireplace produces a clicking/ticking noise just after burner is lit or shut off



POSSIBLE CAUSE
REMEDY
Fireplace produces unwanted odors
products while fireplace is running
Gas odor even when control knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace





This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
KEY M36(B,H) M42(B,H) NO. VM36(B,H) VM42(B,H) DESCRIPTION QTY. 19 106691-01 107839-01 Screen Rod 2 20 ** ** Firebox Top Assembly 1 21 106699-01 106699-01 Transition 6" B-Vent Collar 1 22 106703-01 106703-01 Air Kit Door Assembly 1 23 ** ** Firebox Face 1 24 106948-02 107823-02 Smoke Deflector 1 25 ** ** Fireplace Top Insulation 1 26 107796-01 107796-02 Grate Assembly 1 27 107742-01 107742-02 Burner Pan 1 28 107795-01 107831-01 Burner Tube 1 29 107748-01 107748-01 Burner Bracket 1 30 107985-01 107985-02 Pilot Shield 1 31 901681-01 901681-01 Burner Clamp 1 32 11209 11209 Nut, #10-24 1 33 11147 11147 Screw, #10-24 x 1/2 1 34 901066-01 901066-01 Brass Air Mixer (NG) 1 901066-02 901066-02 Brass Air Mixer (LP) 1 35 901064-03 901064-08 Orifice (NG) 1 901065-13 901065-12 Orifice (LP) 1 36 108084-01 108084-01 Pilot - Natural Gas 1 108084-03 108084-03 Pilot - Propane/LP Gas 1 37 108085-01 108085-01 Pilot Orifice (NG) 1 108085-02 108085-02 Pilot Orifice (LP) 1 38 11102 11102 Screw, #8-32 x 3/8 2 39 14512 14512 Gas Control Valve (NG) 1 14513 14513 Gas Control Valve (LP) 1 40 107741-01 107741-01 Valve Bracket 1 41 14261 14261 Piezo Ignitor 1 42 111288-02 111288-02 Manual Valve with Flex Hose 1 43 108769-01 108769-02 Extension Deflector 2 44 108005-01 108005-01 Wire Harness 1 45 108005-02 108005-02 Wire Harness 1 46 11418 11418 Push-On Nut 2 47 12105 107840-01 Screen 2 48 14123 14123 Strain Relief 1 49 14574 106543-01 Limit Switch 1 50 ** ** Collar Insulation 1 51 20023 20488 Starter Collar 1 52 20027 20027 Brick Liner Retainer 2 53 20042 20042 Air Kit Cover 1 54 20088 20088 Door Stop 1 55 20089 20089 Pivot Clip 2 56 20090 20090 Spring Clip 2 57 20280 20280 Top Spacer 4 58 ** ** Gas Knockout Cover 4 59 ** ** Gas Conduit 1 60 ** — Gas Conduit 1 61 22912 22924 Draft Diverter 1 62 24353 24353 Box Assembly 1 63 11165 11165 Screw, #10 x 5/8 Mod. Tr. Blk. Ox 2 PARTS AVAILABLE NOT SHOWN
KEY M36(B,H) M42(B,H) NO. VM36(B,H) VM42(B,H) DESCRIPTION QTY. 1 14153 14153 Micro Switch 1 2 ** ** Insulation Pan 1 3 ** ** Fireplace Top Assembly 1 4 ** ** Fireplace Surround 1 5 106642-01 106642-01 Air Rod Retainer 1 6 106643-01 106643-01 Damper Rod Retainer 1 7 106651-01 107805-01 Panel Closure 2 8 ** ** Firebox Bottom 1 9 ** ** Firebox Surround 1 10 106657-02 107811-02 Air Separator 1 11 11408 11408 Bushing 2 12 106658-02 107812-02 Left Refractory, Std. Brick (M36B/M42B) 1 108164-02 108169-02 Left Refractory, Herringbone (M36H/M42H) 1 106658-01 107812-01 Left Refractory, Std. Brick (VM36B/VM42B) 1 108164-01 108169-01 Left Refractory, Herringbone (VM36H/VM42H) 1 13 106659-02 107814-02 Right Refractory, Std. Brick (M36B/M42B) 1 108165-02 108170-02 Right Refractory, Herringbone (M36H/M42H) 1 106659-01 107814-01 Right Refractory, Std. Brick (VM36B/VM42B) 1 108165-01 108170-01 Right Refractory, Herringbone (VM36H/VM42H) 1 14 106660-02 107816-02 Rear Refractory, Std. Brick (M36B/M42B) 1 108166-02 108171-02 Rear Refractory, Herringbone (M36H/M42H) 1 106660-01 107816-01 Rear Refractory, Std. Brick (VM36B/VM42B) 1 108166-01 108171-01 Rear Refractory, Herringbone (VM36H/VM42H) 1 15 106661-02 107818-02 Bottom Rear Refractory, Std. Brick (M36/M42, M36B/M42B) 1 108167-02 108172-02 Bottom Rear Refractory, Herringbone (M36H/M42H) 1 106661-01 107818-01 Bottom Rear Refractory, Std. Brick (VM36/VM42, VM36B/VM42B) 1 108167-01 108172-01 Bottom Rear Refractory, Herringbone (VM36H/VM42H) 1 16 106662-02 107820-02 Bottom Front Refractory, Std. Brick (M36/M42, M36B/M42B) 1 108168-02 108173-02 Bottom Front Refractory, Herringbone (M36H/M42H) 1 106662-01 107820-01 Bottom Front Refractory, Std. Brick (VM36/VM42, VM36B/VM42B) 1 108168-01 108173-01 Bottom Front Refractory, Herringbone (VM36H/VM42H) 1 17 ** ** Firebox Support Leg 2 18 106687-01 106887-02 Damper Can Collar 1
901155-01 901155-01 Vermiculite Bag 1 901156-01 901156-01 Pan Material 1 901157-01 901157-01 Lava Rock 1 22180 22180 Wall Switch Kit 1
** Not a field replaceable part.

2B
Logset for Models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H)
Logset for Models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H) KEY PART NO. NUMBER DESCRIPTION QTY.
- 107999-01 Log Set 1 108724-01 Right Front 9" Split Log 1 2 901098-01 Rear Log 1 3 108720-01 Top Right Log - 11 3/4" 1 4 108721-01 Top Right Log - 16" 1 5 108722-01 Top Left Log - 13 1/2" Y-Log 1 6 108723-01 Top Left Log - 11" 1
KEY PART NO. NUMBER DESCRIPTION QTY.
- 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 11" 1 2B 108839-01 Right Front Log - 15 3/4" Round 1 3 108722-01 Top Left Log - 13 1/2" Y-Log 1 4 108838-01 Inside Top Left Log - 15 3/4" Split 1 5 108721-01 Inside Top Right Log - 16" 1 6 108720-01 Top Right Log - 11 3/4" 1

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner's Registration Form and mail to the address on the back of this owner's manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA:
Living/Family Room Office/Warehouse Utility Shed/Outbuilding Garage Bedroom Bathroom Other
100,000 to 250,000 Over 250,000
Fireplace or Hearth Shop Farm Store Other
Emergency Back-Up Heat Heater was on Sale Energy Savings/High Efficiency Construction Project Other
$50,000 to $74,999 $75,000 to $99,999 $100,000 and Over
Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson's Recommendation Friend/Relative's Recommendation Portability Quiet Operation
Not Important Somewhat Important Very Important


2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004



(For VM36(B,H), VM36P(B,H), VM42(B,H) and VM42P(B,H) BL36S - 36" Refractory Standard Brick Liner Kit BL42S - 42" Refractory Standard Brick Liner Kit BL36HS - 36" Refractory Herringbone Brick Liner Kit BL42HS - 42" Refractory Herringbone Brick Liner Kit
Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESAʼs Sales Department at 1-866-672-6040 for information. You can also write -to the address listed on the back page of this manual.
BLOWER KIT BK - Squirrel Cage Blower With Speed Control BK3E - Triple Fan Blower System
AIR KIT - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
PERIMETER TRIM PT36 - 36" Perimeter Trim - Black PT36B - 36" Perimeter Trim - Brushed Brass PT36PB - 36" Perimeter Trim - Polished Brass PT36P - 36" Perimeter Trim - Platinum PT42 - 42" Perimeter Trim - Black PT42B - 42" Perimeter Trim - Brushed Brass PT42PB - 42" Perimeter Trim - Polished Brass PT42P - 42" Perimeter Trim - Platinum
REMOTE CONTROL KITS RC - Standard On/Off Millivolt Remote Control Kit GHRCB - Hand-Held Remote Control Kit GWMT1 - Wall-Mount Remote Control Kit
PROPANE CONVERSION KITS PCBM-36 - Propane Conversion Kit for 36" B-Vent Millivolt Fireplace PCBM-42 - Propane Conversion Kit for 42" B-Vent Millivolt Fireplace
LOUVER TRIM (Rolled Louvers Only) LT36B - 36" Louver Trim Kit - Brushed Brass LT36P - 36" Louver Trim Kit - Platinum LT36PB - 36" Louver Trim Kit for VM36(B,H) - Polished Brass LT42B - 42" Louver Trim Kit - Brushed Brass LT42P - 42" Louver Trim Kit - Platinum LT42PB - 42" Louver Trim Kit for VM42(B,H) - Polished Brass
EXTRUDED ALUMINUM BI-FOLD GLASS DOORS BD36 - 36" Black Finish BD36B - 36" Brushed Brass Finish BD36P - 36" Platinum Finish BD42 - 42" Black Finish BD42B - 42" Brushed Brass Finish BD42P - 42" Platinum Finish
FACE/LOUVER PANEL KITS SP36, SP42 - Smooth Faced Panel Kit- Black SL36, SL42 - Stamped Louver Panel Kit- Black RL36, RL42 - Rolled Louver Kit- Black FP36, FP42 - Filigree Panel Kit- Black FP36B, FP42B - Filigree Panel Kit- Brushed Brass FP36P, FP42P - Filigree Panel Kit- Platinum FP36PB, FP42PB - Filigree Panel Kit- Polished Brass
BRICK LINER (For M36(B,H), M36P(B,H), M42(B,H) and M42P(B,H) BL36 - 36" Refractory Standard Brick Liner Kit BL42 - 42" Refractory Standard Brick Liner Kit BL36H - 36" Refractory Herringbone Brick Liner Kit BL42H - 42" Refractory Herringbone Brick Liner Kit
FIRE CRACKLE - CF6-A Creates the sound of a real burning fire.



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
108795-01 Rev. M 11/04 NOT A UPC
108795 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.