Propane/LP Heater
Owner’s Manual

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, immediately call your gas supplier.
Save this manual for future reference. For more information, visit www.desatech.com

Table of Contents Specifications 2 Safety 2 Propane/LP Safety 4 Unpacking 4 Assembly 5 Operation 8
Storage 9 Servicing 9 Replacement Parts 9 Technical Service 9 Parts 10 Warranty 12
We cannot foresee every use which may be made of our heaters. Check with your local fire safety authority if you have questions about heater use. Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these. Carbon Monoxide Poisoning: Direct-Fired means that all of the combustion products en ter the heated space. Even though this heater operates very close to 100 percent combus tion efficiency, it still produces small amounts of carbon monoxide. Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced. Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.

10. If at any time gas odor is detected, IM MEDIATELY DISCONTINUE operation until the source of gas has been located and corrected. Read Propane/LP Safety, page 4 for additional information about detecting propane leaks. 11. Install the heater such that it is not directly exposed to water spray, rain and/or drip ping water. 12. Maintain minimum clearance to people or normal combustible material (like paper) of 3.6 ft. (1,100 mm) from top and 2 ft. (609 mm) from the reflector. 13. Operate only on a stable, level surface. 14. Do not spray aerosols near the heater during use or shortly thereafter. 15. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water on external surfaces only. Do not submerge in water. 16. Check control compartment burners and circulation air passageways for free air passage, make sure that there are no obstructions. These areas are a com mon location for spider webs, which can present a dangerous condition, damage the heater and render it unsafe for use. The heater must be checked if any of the following conditions exist: a) Gas smell. b) Heater does not reach temperature. c) Uneven burner glow. d) Burner makes popping noises during nor
This is a propane, direct-fired heater. Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, col lecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Read Propane/LP Safety, page 4 for additional information about detecting propane leaks. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane ap plication and supply installation and ask them to check it if there are any questions. When the heater is to be operated in the pres ence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. 1. Check the heater thoroughly for damage. DO NOT operate a damaged heater. 2. DO NOT modify the heater or operate a heater which has been modified from its original condition. 3. Use only propane/LP gas. 4. Use 20 lb. propane/LP tank or larger. 5. Use only VAPOR WITHDRAWAL pro pane supply. The propane cylinder must be arranged for vapor withdrawal, in accordance with the Compress Gas As sociations, Small Propane Bottle Assem bly. If there is any question about vapor withdrawal, ask your propane dealer. 6. Always fully assemble heater before each use. Do not use this heater without securing fuel tank as instructed. Minimum clearance from fuel tank to ground is 2". 7. Use only the hose and regulator assembly provided with the heater. 8. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater. 9. This heater is for OUTDOOR USE ONLY, even so, make sure that there is ample fresh air ventilation. Do not use in build ings, garages or other enclosed spaces.
mal use, other than during shutdown. 17. Use only soapy water (1 part liquid dish washing detergent to 3 parts water) to conduct leak tests whenever a propane cylinder is connected. Bubbles indicate a leak. 18. Do not adjust gas regulator. If you are unsure of your appliances gas type or pressure, call a qualified service person. 19. Always disconnect the gas supply after the heater is turned "OFF". 20. Do not move, handle or service while hot or burning. 21. Allow 45 minutes to cool down after use before attempting to move heater. 22. Do not operate this appliance in windy conditions. Maximum allowable wind speed is 10 mph (16 Km/h). 23. Do not operate this appliance in tempera ture conditions below 40° F (5° C).

Propane/LP Safety
Any guard or other protective device removed for servicing must be re placed prior to operating the heater.
Surface temperatures become very hot when operating heater. Children and adults should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the heater.
Unpacking When assembling for the first time, be sure to remove all packaging from the components prior to beginning assembly.
Clothing or other flammable mate rials should not be hung from the heater, or placed on or near heater.

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartments, burners and circulating air passageways of the heater be kept clean.

Assembly 1. Install threaded poles into triangular base as shown in Figure 1. Be sure to seat poles fully inside base. 2. Install lower legs by pressing push tab release and inserting into upper pole (see Figure 2). Be sure push button is locked in place. 3. Install 3 feet to lower legs as shown in Figure 3. Be sure to tighten wing bolt after installation.


Wing Nut On Inside of Foot
Figure 3 - Installing Feet to Lower Poles

Figure 1 - Base and Pole Assembly



Push Tab Release in Hole of Upper Pole
Figure 2 - Installing Lower Legs into
Figure 4 - Attaching Tank Straps
Push Tab Release · 9"-10" · Upper Poles



Figure 7 - Tank Cover


Wing Nuts and Bolts
Figure 8 - Reflector Assembly

Bolts on Top of Burner Assembly
Min. 2" from Tank to Ground
Figure 5 - Attaching Tank Straps to Base


Figure 9 - Attaching Reflector and Reflector Cap to Burner Assembly
Figure 6 - Tank Restraint Straps
Reflector Cap · Wing Nut

13. Lift tank cover. Install regulator hose to burner fuel line using wrenches provided in hardware bag (see Figure 11). 14. Securely connect regulator to propane/LP gas cylinder (see Figure 12). When con necting regulator assembly to tank valve, hand tighten nut clockwise to a positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage quick clos ing coupling nut and result in a hazardous condition. 15. Open cylinder valve. Apply a noncorrosive leak detection fluid to connections at regulator. Bubbles forming show a leak. 16. If leaks exist, turn off propane/LP cylinder valve. Disconnect leaking connection. Check and clean connection. Reconnect regulator and leak check again. 17. If no leaks are present, pull cover down over tank and legs. Unit is now ready to light.


Figure 11 - Attaching Regulator Hose to


Align Hole in Burner Assembly With Hole in Upper Pole
Figure 12 - Connecting Regulator to
Figure 10 - Burner Installation
Burner Fuel Line · Propane/LP Gas Tank

TO LIGHT 1. Open the main gas supply valve on pro pane cylinder. 2. Open manual valve. 3. Press and hold silver control valve button for 3 seconds. While holding valve button, press red igniter button until the burner is lit (may require pushing more than once). Continue to hold the heater control valve for 30 seconds then release. 4. TO MATCH LIGHT: Insert flame into match hole near burner. Press and hold control valve button until flame is lit. Continue to hold valve button for 30 seconds. IMPORTANT: Smoke and odor (not a gas odor) emission may occur in the first 15 min utes of use. Run heater at high setting for at least 15 minutes to eliminate this problem.
Before You Use Your Heater 1. Move heater to an open area. 2. Make sure tank valve is in its full off posi tion (turn clockwise to stop). 3. Check tank valve features to ensure it has proper external mating threads. (Tank valve marked USE WITH TYPE 1.) 4. Never attempt to use any components that have been damaged or exposed to an accidental fire. The connection provided with this heater incorporates two important features: Tem perature Activated Shutoff and Excess Flow Control.
TO SHUT DOWN 1. Shut off main gas supply. 2. Close manual valve. 3. Wait 5 minutes before relighting heater.

Figure 13 - Control Valve and Ignitor Buttons

Storage 1. Allow at least 45 minutes for heater to cool down after using. 2. Disassemble heater in reverse order that it was assembled. 3. Place all hardware in provided tool bag.
Technical Service A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, or if you have further ques tions about this heater, contact DESA Heat ing Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ Tech nical Service web site at www.desatech.com. You may also obtain in-warranty or out-of- warranty service by taking the product to your local service center.



Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 9 of this manual.

Serial No.
RECONDITIONED PRODUCTS
New Products: DESA Heating, LLC warrants this heater and any parts thereof, to be free of defects in materials and workmanship for one (1) year from the date of first purchase, when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.
Factory Reconditioned Heaters: DESA Heating, LLC warrants this factory reconditioned heater and any parts thereof, to be free of defects in materials and workmanship for thirty (30) days from the date of first purchase, when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.
These warranties cover only the cost of parts and labor required to restore the product to proper operat ing condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.
Warranty service is available only through authorized dealers and service centers.
This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear, alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.
THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU LAR PURPOSE.
DESA Heating, LLC assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This warranty does not cover discoloration due to operation of heater. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA Heating, LLC will repair or replace the heater without charge.
Return the heater to your nearest authorized service center. Each Service Center is independently owned and operated. Repairs not covered by the warranty will be billed at standard prices. We reserve the right to amend these specifications at any time without notice.
For information about this warranty write:
DESA Heating, LLC 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desaint.com 1-866-846-6040
120948-01 Rev. A 03/07
Model · Date of Purchase