Page 1

Heat-N-Go Portable

Propane/LP Heater

Owner’s Manual

Desa TD120 — Heat-N-Go Portable diagram (page 1)
Fig. 1 · Heat-N-Go Portable

MODELS TD120, TD121, TD122, TD123, TD124, TD129

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

FOR YOUR SAFETY If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, immediately call your gas supplier.

Save this manual for future reference. For more information, visit www.desatech.com

Page 2 of the Desa TD120 user manual — Safety
Page 2 · click to enlarge
Page 2

Table of Contents Specifications 2 Safety 2 Propane/LP Safety 4 Unpacking 4 Assembly 5 Operation 8

Storage 9 Servicing 9 Replacement Parts 9 Technical Service 9 Parts 10 Warranty 12

  • Specifications
  • Rating: 21,000 Btu/hr (6.15 kW)
  • Type of Gas: Propane/LP Only
  • Gas Supply Pressure to regulator: Maximum - 150 psi (1034.2 kPa), Minimum - 5 psi (34.5 kPa)
  • Gas Supply Pressure Regulator out: 11" W.C. (2.74 kPa)
  • Ignition: Piezo Ignition
  • Fuel Consumption: 1.07 lbs./hr (0.49 kg/hr)
  • Flame Safety: Thermocouple Operated Gas Valve

Safety

We cannot foresee every use which may be made of our heaters. Check with your local fire safety authority if you have questions about heater use. Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these. Carbon Monoxide Poisoning: Direct-Fired means that all of the combustion products en ter the heated space. Even though this heater operates very close to 100 percent combus tion efficiency, it still produces small amounts of carbon monoxide. Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced. Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.

Page 3 of the Desa TD120 user manual — Safety
Page 3 · click to enlarge
Page 3

Safety

10. If at any time gas odor is detected, IM MEDIATELY DISCONTINUE operation until the source of gas has been located and corrected. Read Propane/LP Safety, page 4 for additional information about detecting propane leaks. 11. Install the heater such that it is not directly exposed to water spray, rain and/or drip ping water. 12. Maintain minimum clearance to people or normal combustible material (like paper) of 3.6 ft. (1,100 mm) from top and 2 ft. (609 mm) from the reflector. 13. Operate only on a stable, level surface. 14. Do not spray aerosols near the heater during use or shortly thereafter. 15. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water on external surfaces only. Do not submerge in water. 16. Check control compartment burners and circulation air passageways for free air passage, make sure that there are no obstructions. These areas are a com mon location for spider webs, which can present a dangerous condition, damage the heater and render it unsafe for use. The heater must be checked if any of the following conditions exist: a) Gas smell. b) Heater does not reach temperature. c) Uneven burner glow. d) Burner makes popping noises during nor

This is a propane, direct-fired heater. Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, col lecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Read Propane/LP Safety, page 4 for additional information about detecting propane leaks. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane ap plication and supply installation and ask them to check it if there are any questions. When the heater is to be operated in the pres ence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. 1. Check the heater thoroughly for damage. DO NOT operate a damaged heater. 2. DO NOT modify the heater or operate a heater which has been modified from its original condition. 3. Use only propane/LP gas. 4. Use 20 lb. propane/LP tank or larger. 5. Use only VAPOR WITHDRAWAL pro pane supply. The propane cylinder must be arranged for vapor withdrawal, in accordance with the Compress Gas As sociations, Small Propane Bottle Assem bly. If there is any question about vapor withdrawal, ask your propane dealer. 6. Always fully assemble heater before each use. Do not use this heater without securing fuel tank as instructed. Minimum clearance from fuel tank to ground is 2". 7. Use only the hose and regulator assembly provided with the heater. 8. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater. 9. This heater is for OUTDOOR USE ONLY, even so, make sure that there is ample fresh air ventilation. Do not use in build ings, garages or other enclosed spaces.

mal use, other than during shutdown. 17. Use only soapy water (1 part liquid dish washing detergent to 3 parts water) to conduct leak tests whenever a propane cylinder is connected. Bubbles indicate a leak. 18. Do not adjust gas regulator. If you are unsure of your appliances gas type or pressure, call a qualified service person. 19. Always disconnect the gas supply after the heater is turned "OFF". 20. Do not move, handle or service while hot or burning. 21. Allow 45 minutes to cool down after use before attempting to move heater. 22. Do not operate this appliance in windy conditions. Maximum allowable wind speed is 10 mph (16 Km/h). 23. Do not operate this appliance in tempera ture conditions below 40° F (5° C).

Page 4 of the Desa TD120 user manual — Safety
Page 4 · click to enlarge
Page 4

Safety

Propane/LP Safety

24. Keep heater away from areas where flam mable liquids, vapors or solids are stored or used. 25. If operated in salt air environments, the unit will require more frequent cleaning; otherwise, the longevity of the unit will deteriorate rapidly. Use warm soapy water to clean the unit. 26. Items or material, when stored under the heater, will be subjected to radiant heat and could be seriously damaged.
  • Asphyxiation Hazard
  • Do not use this heater for heating human or animal living quarters.
  • Do not use in unventilated areas.
  • The flow of combustion and ventilation air must not be obstructed.
  • Proper ventilation air must be provided to support the combustion air require ments of the heater being used.
  • Refer to the Specifications , page 2, heat er data plate or contact DESA Heating Products to determine combustion air ventilation requirements of the heater.
  • Lack of proper ventilation air will lead to improper combustion.
  • Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon mon oxide poisoning can include headaches dizziness and difficulty in breathing.

Any guard or other protective device removed for servicing must be re placed prior to operating the heater.

Surface temperatures become very hot when operating heater. Children and adults should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the area of the heater.

Unpacking When assembling for the first time, be sure to remove all packaging from the components prior to beginning assembly.

Clothing or other flammable mate rials should not be hung from the heater, or placed on or near heater.

Desa TD120 — Safety diagram (page 4)
Fig. 2 · Safety

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartments, burners and circulating air passageways of the heater be kept clean.

Page 5 of the Desa TD120 user manual — Assembly
Page 5 · click to enlarge
Page 5

Assembly 1. Install threaded poles into triangular base as shown in Figure 1. Be sure to seat poles fully inside base. 2. Install lower legs by pressing push tab release and inserting into upper pole (see Figure 2). Be sure push button is locked in place. 3. Install 3 feet to lower legs as shown in Figure 3. Be sure to tighten wing bolt after installation.

4. Install tank straps to propane/LP gas cylinder as shown in Figure 4. Length of strap from tank flange to end of clip should be between 9" and 10" from tank flange. This should maintain a 2" minimum clear ance from bottom of propane/LP tank to ground.
Desa TD120 — Assembly diagram (page 5)
Fig. 3 · Assembly
Desa TD120 — Assembly diagram (page 5)
Fig. 4 · Assembly

Wing Nut On Inside of Foot

Figure 3 - Installing Feet to Lower Poles

Desa TD120 — Assembly diagram (page 5)
Fig. 5 · Assembly

Figure 1 - Base and Pole Assembly

Desa TD120 — Assembly diagram (page 5)
Fig. 6 · Assembly
Desa TD120 — Assembly diagram (page 5)
Fig. 7 · Assembly
Desa TD120 — Assembly diagram (page 5)
Fig. 8 · Assembly

Push Tab Release in Hole of Upper Pole

Figure 2 - Installing Lower Legs into

Figure 4 - Attaching Tank Straps

Push Tab Release · 9"-10" · Upper Poles

Page 6 of the Desa TD120 user manual — Assembly
Page 6 · click to enlarge
Page 6

Assembly

Desa TD120 — Assembly diagram (page 6)
Fig. 9 · Assembly
5. Install tank straps to base as (see Figure 5). 6. Install tank restraint to tank and fasten restraint straps around legs as shown in Figure 6. 7. Install the tank cover (see Figure 7). 8. Assemble reflector with small wing nuts and bolts as shown in Figure 8. 9. Install reflector over post on top of burner assembly. Install reflector cap over post. Attach reflector and reflector cap using large wing nuts (see Figure 9).
Desa TD120 — Assembly diagram (page 6)
Fig. 10 · Assembly

Figure 7 - Tank Cover

Desa TD120 — Assembly diagram (page 6)
Fig. 11 · Assembly
Desa TD120 — Assembly diagram (page 6)
Fig. 12 · Assembly

Wing Nuts and Bolts

Figure 8 - Reflector Assembly

Desa TD120 — Assembly diagram (page 6)
Fig. 13 · Assembly

Bolts on Top of Burner Assembly

Min. 2" from Tank to Ground

Figure 5 - Attaching Tank Straps to Base

Desa TD120 — Assembly diagram (page 6)
Fig. 14 · Assembly
Desa TD120 — Assembly diagram (page 6)
Fig. 15 · Assembly

Figure 9 - Attaching Reflector and Reflector Cap to Burner Assembly

Figure 6 - Tank Restraint Straps

Reflector Cap · Wing Nut

Page 7 of the Desa TD120 user manual — Assembly
Page 7 · click to enlarge
Page 7

Assembly

13. Lift tank cover. Install regulator hose to burner fuel line using wrenches provided in hardware bag (see Figure 11). 14. Securely connect regulator to propane/LP gas cylinder (see Figure 12). When con necting regulator assembly to tank valve, hand tighten nut clockwise to a positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage quick clos ing coupling nut and result in a hazardous condition. 15. Open cylinder valve. Apply a noncorrosive leak detection fluid to connections at regulator. Bubbles forming show a leak. 16. If leaks exist, turn off propane/LP cylinder valve. Disconnect leaking connection. Check and clean connection. Reconnect regulator and leak check again. 17. If no leaks are present, pull cover down over tank and legs. Unit is now ready to light.

10. Inspect length of gas hose on bottom of burner assembly for any cracks, cut, holes or excessive wear. Do not use heater if hose is damaged. 11. Sliding hose into upper pole, install burner and reflector assembly to base (see Fig ure 10). 12. Align hole in burner assembly pole with hole in upper pole (see Figure 10). Secure burner assembly to upper pole using a wing bolt. Be sure to tighten wing nut completely.
Desa TD120 — Assembly diagram (page 7)
Fig. 16 · Assembly
Desa TD120 — Assembly diagram (page 7)
Fig. 17 · Assembly

Figure 11 - Attaching Regulator Hose to

Desa TD120 — Assembly diagram (page 7)
Fig. 18 · Assembly
Desa TD120 — Assembly diagram (page 7)
Fig. 19 · Assembly

Align Hole in Burner Assembly With Hole in Upper Pole

Figure 12 - Connecting Regulator to

Figure 10 - Burner Installation

Burner Fuel Line · Propane/LP Gas Tank

Page 8 of the Desa TD120 user manual — Operation
Page 8 · click to enlarge
Page 8

Operation

TO LIGHT 1. Open the main gas supply valve on pro pane cylinder. 2. Open manual valve. 3. Press and hold silver control valve button for 3 seconds. While holding valve button, press red igniter button until the burner is lit (may require pushing more than once). Continue to hold the heater control valve for 30 seconds then release. 4. TO MATCH LIGHT: Insert flame into match hole near burner. Press and hold control valve button until flame is lit. Continue to hold valve button for 30 seconds. IMPORTANT: Smoke and odor (not a gas odor) emission may occur in the first 15 min utes of use. Run heater at high setting for at least 15 minutes to eliminate this problem.

  • WARNING: If you smell gas:
  • Shut off gas to the appliance.
  • Extinguish any open flames.
  • If odor continues, immediately call your gas supplier. See safety warnings and pre cautions starting on the front page of this manual for more information.

Before You Use Your Heater 1. Move heater to an open area. 2. Make sure tank valve is in its full off posi tion (turn clockwise to stop). 3. Check tank valve features to ensure it has proper external mating threads. (Tank valve marked USE WITH TYPE 1.) 4. Never attempt to use any components that have been damaged or exposed to an accidental fire. The connection provided with this heater incorporates two important features: Tem perature Activated Shutoff and Excess Flow Control.

TO SHUT DOWN 1. Shut off main gas supply. 2. Close manual valve. 3. Wait 5 minutes before relighting heater.

Desa TD120 — Operation diagram (page 8)
Fig. 20 · Operation

Figure 13 - Control Valve and Ignitor Buttons

Show 4 more labels / short text on this page
Match Hole · Control Valve Button · Ignitor Button · Manual Valve
Page 9 of the Desa TD120 user manual — Replacement Parts
Page 9 · click to enlarge
Page 9

Storage 1. Allow at least 45 minutes for heater to cool down after using. 2. Disassemble heater in reverse order that it was assembled. 3. Place all hardware in provided tool bag.

Replacement Parts

4. Store unit in bag until ready to use again.
  • Servicing To assure safety, proper function and lon gevity of the heater, regular maintenance is required. The frequency of maintenance will depend on the usage of the unit. Review the following concerning the criteria for a properly functioning heater. Failing to follow proper, regular maintenance will void warranty. A hazardous condition may result if a heater is used that has been modified or is not func tioning properly. When the heater is working properly:
  • The flame is contained within the heater.
  • The flame is essentially blue with some yellow tipping.
  • There is no strong disagreeable odor, eye burning or other physical discomfort.
  • There is no smoke or soot internal or ex ternal to the heater.
  • If your heater will not light or stay lit, contact a qualified service person. The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT: Do not use alternates. For this heater, the regulator must be set as shown in Specifications, page 2. If there is any uncertainty about the regulator setting, have it checked.
  • Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central or call DESA Heating Products’ Technical Ser vice Department at 1-866-672-6040. When calling DESA Heating Products, have ready
  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • purchase date
  • Parts Not Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (listed in Authorized Service Center booklet) or call DESA Heating Products at 1-866-672-6040 for referral information. When calling DESA Heating Products, have ready
  • model number of your heater
  • serial number of your heater

Technical Service A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, or if you have further ques tions about this heater, contact DESA Heat ing Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ Tech nical Service web site at www.desatech.com. You may also obtain in-warranty or out-of- warranty service by taking the product to your local service center.

Page 10 of the Desa TD120 user manual — Models TD120, TD121, TD122, TD123, TD124, TD129
Page 10 · click to enlarge
Page 10

Parts

Models TD120, TD121, TD122, TD123, TD124, TD129

Desa TD120 — Models TD120, TD121, TD122, TD123, TD124, TD129 diagram (page 10)
Fig. 21 · Models TD120, TD121, TD122, TD123, TD124, TD129
Page 11 of the Desa TD120 user manual — Models TD120, TD121, TD122, TD123, TD124, TD129
Page 11 · click to enlarge
Page 11

Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 9 of this manual.

Models TD120, TD121, TD122, TD123, TD124, TD129

1121014-01Reflector Cap1 2121015-01Reflector3 3121016-01Burner Emitter1 4121017-01Main Burner1 5121018-01Copper Nut, M10 x 11 6121019-01Igniter Electrode1 7121020-01Igniter Support Bracket1 8121021-01Thermocouple Assembly1 9121022-01Orifice, 1.35 mm1 10121023-01Control Valve Assembly1 11121024-01Connector Tube1 12121025-01Burner Base1 13121026-01Base Tube1 14121027-01Valve Rod1 15121028-01Igniter1 16121029-01Bulkhead Fitting1 17121030-01LP Gas Hose Assembly1 18121031-01Burner Pole1 19121032-01Pole & Base Assembly1 20121034-01Upper Threaded Legs3 21121035-01Lower Legs3 22121036-01Metal Foot3 23113793-01Ball Valve Assembly1 24113810-01Ball Valve Knob Insert1 25113809-01Ball Valve Knob1 PARTS NOT SHOWN 121037-01Hardware Bag1 121038-01Wing Nut Bolt, 3/16"-24 x 3/8"4 121039-01Screw, 3/16"- 24 x 3/8"3 121040-01Wing Nut, 3/16" - 243 121041-01Wing Nut, 5/16" - 183 121042-01Flat Metal Wrench Set (3/4" & 5/8")1 121051-01Heater Bag1 121066-01Tank Cover1 121065-01Regulator1 121091-01Tank Straps2 121092-01Tank Restraint1
Page 12 of the Desa TD120 user manual — REPAIR SERVICE
Page 12 · click to enlarge
Page 12

Warranty KEEP THIS WARRANTY

Serial No.

LIMITED WARRANTIES FOR NEW AND FACTORY

RECONDITIONED PRODUCTS

New Products: DESA Heating, LLC warrants this heater and any parts thereof, to be free of defects in materials and workmanship for one (1) year from the date of first purchase, when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.

Factory Reconditioned Heaters: DESA Heating, LLC warrants this factory reconditioned heater and any parts thereof, to be free of defects in materials and workmanship for thirty (30) days from the date of first purchase, when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.

These warranties cover only the cost of parts and labor required to restore the product to proper operat ing condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.

Warranty service is available only through authorized dealers and service centers.

This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear, alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.

THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU LAR PURPOSE.

DESA Heating, LLC assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

This warranty does not cover discoloration due to operation of heater. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

WARRANTY SERVICE

Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA Heating, LLC will repair or replace the heater without charge.

REPAIR SERVICE

Return the heater to your nearest authorized service center. Each Service Center is independently owned and operated. Repairs not covered by the warranty will be billed at standard prices. We reserve the right to amend these specifications at any time without notice.

For information about this warranty write:

DESA Heating, LLC 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desaint.com 1-866-846-6040

120948-01 Rev. A 03/07

Model · Date of Purchase

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa TD120

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa TD120

Be the first to ask — other owners or our team will answer.

Original document

Desa TD120 manual PDF

24 pages·4.8 MB·Electric Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…