Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
www .desatech.com 1 15043-01C 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier .
www .desatech.com 1 15043-01C 3 W ARNING: This appliance is equipped for natural gas. An opti onal pr opan e/LP conv ersi on kit must be installed for use with propane/LP gas. W ARNING: Do not allow fans to b low dir ect ly into t he fire pl ace . A void any drafts th at alter bu rne r flame patterns.
www .desatech.com 1 15043-01C 4 1. If you smell gas • shut off gas supply • do not try to light any appliance • do not tou ch any elec tric al swit ch; do not use any pho ne i n yo ur b uil ding • immediately call your gas supplier from a neighbor ʼ s phone.
www .desatech.com 1 15043-01C 5 UNP ACKING CA UTI ON: Do not re move th e data plates from the burner pan. The data plates contain impor- tant product information. 1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment.
www .desatech.com 1 15043-01C 6 The fireplace must include a working flue and vent ing syst em with the min imum open ings show n in the Figure 2. INST ALLA TION Continued Figure 2 - T echnical Information Charts Model Burner Descrip- tion BTU Input (Natural Gas) Min.
www .desatech.com 1 15043-01C 7 CAUT ION: Use only ne w , black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to log set.
www .desatech.com 1 15043-01C 8 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Clos e e quip ment shu tof f valv e (s ee F igu re 5 ). 2. Pressurize supply piping system by either us - ing compressed air or opening main gas valve located on or near gas meter .
www .desatech.com 1 15043-01C 9 INST ALLA TION Continued OPTIONAL GA9050A ON/OFF SAFETY V AL VE/PILOT KIT For additional convenience and safety , or for propane/LP conversion, an optional ON/OFF safety valve/pilot kit is available. See Accessories , page 18.
www .desatech.com 1 15043-01C 10 INST ALLA TION Continued Figure 1 1 - Installing T op Logs Figure 10 - Installing Middle Logs OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: Keep flue open when operating unit.
www .desatech.com 1 15043-01C 1 1 Shutting Off Appliance T urn gas shutoff valve clockwise to the OFF position. CURING LOGS During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure.
www .desatech.com 1 15043-01C 12 CLEANING AND MAINTENANCE • Keep the area around the log set clean and clear of debris. • Occasionally , you may use a soft bristle brush to clean logs. • Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace.
www .desatech.com 1 15043-01C 13 TROUBLESHOO TING W ARNING: T urn off log set and let cool before servicing. Only a qualified service person should service and repair log set. Note: All troubleshooting items are listed in order of operation. POSSIBLE CAUSE 1.
www .desatech.com 1 15043-01C 14 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Ga s sup pl y tu rne d of f or eq uip- ment sh utof f valv e cl ose d 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. A i r in g a s l i n es w h e n i n- stalled 5 .
www .desatech.com 1 15043-01C 15 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Me tal exp and ing whi le he at ing or c ont ract ing whil e c ooli ng 1. Log Set burning vapors from paint, hair spray , glues, clean - ers, chemicals, new carpet, etc. (See IMPOR T ANT state- ment above) 2 .
www .desatech.com 1 15043-01C 16 ILL USTRA TED P ARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17.
www .desatech.com 1 15043-01C 17 P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual.
www .desatech.com 1 15043-01C 18 ACCESSORIES Purchase these log set accessories from your local deal er . If they can not supply thes e accesso rie s, call DESA at 1-866-67 2-6040 for referral informatio n. Y ou can also write to the addres s listed on the back page of this manual.
www .desatech.com 1 15043-01C 19 NO TES _____________________________________________________ ______________________________________________________ ___________________________________________________.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 15043-01 Rev . C 06/05 115043 01 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
An important point after buying a device Desa LCF18 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa LCF18 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa LCF18 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa LCF18 you will learn all the available features of the product, as well as information on its operation. The information that you get Desa LCF18 will certainly help you make a decision on the purchase.
If you already are a holder of Desa LCF18, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa LCF18.
However, one of the most important roles played by the user manual is to help in solving problems with Desa LCF18. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa LCF18 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center