DUAL BURNER FIREPLACE
For more information, visit www.desatech.com For more information, visit www.desatech.com

Remote-Ready Models: VDCFRN, VDCFRP, FDCFRN, FDCFRP
Shown with Optional Cabinet Mantel/Hearth
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference. Save this manual for future reference.
Base Accessory



Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

Figure 1 - Vent-Free Compact Dual Flame Fireplace
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


OPTIONAL REMOTE CONTROL ACCESSORIES LOCAL CODES PRODUCT FEATURES UNPACKING HOOD ASSEMBLY
HOOD ASSEMBLY

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.
Thermostat-Controlled models have a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.
Figure 2 - Removing and Installing Screen

Figure 3 - Assembling Hood
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Screen


Providing Adequate Ventilation Determining Fresh-Air Flow for Fireplace Location

c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of these three criteria, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
Today’s homes are built more energy efficient than ever. New mate- rials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location, below. Confined and Unconfined Space
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Length x Width x Height = cu. ft. (volume of space)
Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft. (volume of space)
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and
If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
(volume of space) x 20 = (Maximum Btu/Hr the space
Example: 1792 cu. ft. (volume of space) x 20 = 35,840 (maximum Btu/Hr the space can support)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
can support)


Determining Fresh-Air Flow for Fireplace Location (Cont.) Ventilation Air
Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.

Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
40,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 7.
Figure 4 - Ventilation Air from Inside Building
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


INSTALLATION
NOTICE: This heater is intended for use as supplemen- tal heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 5 - Ventilation Air from Outdoors
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Outlet Air


Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 9).

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
An optional blower kit is available from your dealer. See Accesso- ries, pages 36 and 37. If planning to use blower, follow instructions provided with blower for power source.
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 6. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 6). B. Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches. C. For mantel clearances, see Figure 10 on page 10.
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 36 and 37.


If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an CSA approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, pages 36 and 37).
*Minimum 16 inches from Side Wall
If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 9 to secure your fireplace into the wall.
Figure 6 - Minimum Clearance for Combustible to Wall
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com



Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accessories, pages 36 and 37). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 10, page 10. Follow the instructions below to install the fireplace in this manner.
Note: A qualified installer should make all electrical connections. 3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not installed hood, follow instructions on page 4. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Con- necting Equipment Shutoff Valve to Heater Control, page 15. 7. Bend four nailing flanges on outer casing with pliers (see Figure 9). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Con- nections, page 16. 10. If using optional brass trim kit, install the trim after final fin- ishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.
Height 26" 26 7/8"
Front Width 26 3/4" 26 7/8"
Depth 14 1/4" 15 1/4"
1. Frame in rough opening. Use dimensions shown in Figure 7 for the rough opening. If installing in a corner, use dimensions shown in Figure 8 for the rough opening. The height is 26 7/8" which is the same as the wall opening above. 2. If installing GA3450TA blower accessory, do so at this time. Follow instructions included with blower accessory. Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installa- tion (see Accessories, pages 36 and 37). Use only approved three-wire electrical wiring.


Figure 7 - Rough Opening for Installing in Wall
Nails or Wood Screws
435/16" 305/8"
611/4" 267/8"
Figure 8 - Rough Opening for Installing in Corner
Figure 9 - Attaching Fireplace to Wall Studs
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Actual Framing · Wall Studs


Note: Refer to instructions provided with the mantel for assembly instructions. Refer to the following instructions for system installa- tion. Refer to instructions on page 4 for hood assembly. Blower accessory should be installed if it is being used (see Installing Optional Blower Accessory GA3450TA, pages 11 through 13). 1. Unscrew four screws that attach top louver to fireplace. Re- move louver from fireplace and set aside (see Figure 11). 2. Place base assembly next to wall at installation location. 3. Place fireplace on wood base (see Figure 12, page 11). 4. Place mantel around fireplace on base (see Figure 12, page 11). 5. Assemble perimeter trim kit. See Assembling Perimeter Trim, page 11. 6. Firmly snap perimeter trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12, page 11). 7. Align perimeter trim kit for flush fit around opening. 8. Center mantel left to right on base making sure mantel is flush against wall. 9. Use two 3" wood screws provided and attach base of fireplace to wooden mantel base (see Figure 12, page 11). 10. Remove perimeter trim kit and mantel. Be careful not to dam- age wall or mantel. 11. Cut an access hole in base to run flexible gas line to fireplace (see Figure 12, page 11). Make sure to locate access hole so mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over. 12. Install gas line. See Connecting To Gas Supply, pages 14 and 15.
If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
2 1/2"
O
O
O
T
O
N
F
F
P
Figure 10 - Minimum Mantel Clearances for Built-In Installation
Figure 11 - Removing Top Louver and Opening Bottom Louver
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


INSTALLATION Optional Mantel Installation (Cont.) Installing Optioanl Blower Accessory GA3450TA
13. Check for leaks. See Checking Gas Connections, page 16. 14. Place mantel around fireplace. Be careful not to damage wall or mantel. 15. Place perimeter trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap trim over shoulder screws on fireplace (see Figure 12). 16. Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for top louver (see Figure 12). 17. Reinstall top louver.
Assembling Perimeter Trim (Perimeter trim shipped with mantel) 1. Remove packaging from three remaining pieces of trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 13. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 13). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side perimeter trim (see Figure 13). 6. While firmly holding edges of perimeter trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other corner. 8. Set perimeter trim assembly aside for later installation.


Removing Upper Louver
Hole for 3" Wood Screw for Attaching Fireplace to Mantel
To install the blower accessory, you must first remove the upper louver. 1. Lift screen off fireplace and remove log set if installed. 2. Remove 4 screws from upper louver (see Figure 11, page 10). Save these screws. 3. Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside. 4. Open lower louver door by swinging door down (see Figure 11, page 10).
Gas Line Access Hole
Hole for 3" Wood Screw for Attaching Fireplace to Wooden Base
Figure 12 - Attaching Brass Trim to Fireplace
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


5. In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 14). 6. Route the wire harness through the hole in left side of baffle and between firebox wrapper and outer casing. 7. Insert the 4 wire harnesses from behind the remote/blower bracket through hole in rear of bracket with bushing and through the left rectangular hole to front of fireplace (see Figure 14). 8. Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires. 9. Install the switch plate on the remote/blower bracket with 2 #10 screws provided (see Figure 16). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 14). Plug fan kit into 120-Volt grounded power sup- ply and test operation. Note: When switch is in the AUTO posi- tion, the fan will start after the fireplace has run for a few mo- ments. The fan will continue to run for several moments after the fireplace has been turned off. When switch is in the ON position, the fan will run until turned to OFF. 10. Reinstall upper louver beginning with bottom screws (see Fig- ure 11, page 10). Close lower louver door.

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 13. 1. Install snap bushings found in blower kit into hole in left side of outer casing and into one of the holes in rear of remote/ blower bracket. 2. Make sure the wire harness is firmly connected to the termi- nals on the blower bracket assembly. 3. Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 14). 4. Carefully disconnect green and white wires at their insulated connectors (see Figure 15).
Wiring Routing Hole in Baffle
Wire Harness Blower Bracket Assembly


Figure 15 - Wiring Diagram For Blower Accessory Standard Installation

Figure 16 - Installing Switch Plate to Remote/Blower Bracket
Figure 14 - Installing Blower Bracket Assembly (Remote-Ready Unit Shown)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com




1. Install snap bushing from blower kit into one hole on rear of re- mote/blower bracket (see Figure 17). The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply. 2. Follow steps 2 through 6 in Installing Blower Accessory, page 12. 3. A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring harness (see Figure 18). 4. Plug power cord to outlet receptacle (not provided) as shown in Figure 17. Wind extra cable of power cord and tie up with plas- tic wire strap (see Figure 17). Set cable bundle between the re- mote/blower bracket and outer casing, away from the burner. 5. Test to make sure blower is working properly. 6. Reinstall upper louver beginning with bottom screws (see Fig- ure 11, page 10) and close lower louver.
Figure 18 - Wiring Diagram For Blower Accessory Built-In Installation
Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Fan Switch (Auto/Off/On)


Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 19. Pointing the vent down protects it from freezing rain or sleet.
Figure 19 - External Regulator With Vent Pointing Down
Approved Flexible Gas Line
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*


PROPANE/LP From External Regulator (11" W.C.** to 14" W.C. Pressure)
NATURAL From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figures 20).
Figure 20 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 38 and 39.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


INSTALLATION Connecting To Gas Supply (Cont.) Connecting Equipment Shutoff Valve To Heater Control
We recommend that you install a sediment trap in supply line as shown in Figure 20, page 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.


Figure 21 - Flexible Gas Line Location (Remote-Ready Unit Shown)
To Gas Regulator (Thermostat- Controlled Models) or Control Valve (Remote-Ready Models) Equipment Shutoff Valve

Flexible Gas Line from Fireplace Gas Regulator Provided With Fireplace
PROPANE/LP To External Regulator
NATURAL To Gas Supply
Figure 22 - Attaching Flexible Gas Line to Equipment Shutoff Valve
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Lower Louver · Flexible Gas Line



Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 23). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas regulator (Thermostat-Controlled Models), or to gas control valve (Remote- Ready Models) (see Figures 24 or 25). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fireplace, pages 19 through 23). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 20 for Thermostat-Controlled Models or page 22 for Remote- Ready Models).
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect fireplace and equipment shutoff valve to gas sup- ply. Check reconnected fittings for leaks.
Gas Regulator or Gas Control Valve

Figure 24 - Checking Gas Joints (Propane/LP Only)
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 23). 2. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air.
Gas Regulator or Gas Control Valve

OFF POSITION
Figure 23 - Equipment Shutoff Valve
Figure 25 - Checking Gas Joints (Natural Gas Only)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Equipment Shutoff Valve · Open · Closed


INSTALLATION Optional Wireless Hand-Held Remote Control Accessories [Remote-Ready Models Only]
OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only ([C]GHRCB Series & [C]GHRCTB Series)
Installing 9-Volt Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to the battery (not included). Place bat-
tery into the battery housing. 3. Replace battery cover onto remote control unit.
Installing Receiver 1. Disconnect wires from the control valve (see Figure 26) . 2. Locate the battery clip mounted on the back of the receiver (see Figure 27). 3. Slide 9-volt battery (not included) through the clip. 4. Attach the terminal wires to the battery (see Figure 27). 5. Connect wires from remote receiver to control valve as shown in Figure 28. 6. Install remote receiver unit onto remote/blower bracket using screws provided (see Figure 28).


Figure 29 - Installing Battery in Hand-Held Remote Control Unit (GHRCB and CGHRCB Series)

Figure 26 - Disconnecting Wires From Control Valve

Figure 30 - Installing Battery in Hand-Held Remote Control Unit (GHRCTB and CGHRCTB Series)
Figure 27 - Attaching Battery to Receiver

Figure 28 - Installing Remote Receiver
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


Optional Wall Mounted Thermostat - GWMT1 (Remote-Ready Models Only) Optional Wall Switch - GWMS2 (Remote-Ready Models Only)

Feed wires through rectangular slots
1. Remove jumper wire from control valve (see Figure 26, page 17). 2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the "THTP" terminal on the control valve. See Figure 31. 3. Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened. The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air condi- tioning ducts. 4. Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base. 5. Feed the electrical wires through the rectangular slots on each side of the base (see Figure 32).
R
Figure 33 - Thermostat Base Terminals “W” and “R”
Figure 32 - Back View of Thermostat Base
To Wall Thermostat or Switch
To Wall Thermostat or Switch
Figure 31 - Connecting Wire Terminals
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Terminal “W” · Terminal “R” · Control Valve


INSTALLATION Installing Log Set and Screen OPERATING FIREPLACE (THERMOSTAT-CONTROLLED MODELS)
INSTALLING LOG SET AND SCREEN 1. Remove log packaging material and discard packaging. Gen- tly place log over burner (see Figure 34). Do not allow log to contact flame. If flame contacts log, soot will be created. 2. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.


1. STOP! Read the safety information above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 35). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Figure 34 - Installing Log and Screen

Ignitor Button Control Knob
Figure 35 - Control Knob In The OFF Position
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


Lighting Instructions (Cont.) To Turn Gas Off To Appliance Thermostat Control Operation Manual Lighting Procedure Operating Blower
The control knob can be set to any heat level between HI and LO.
6. With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 26 through 28. Also, contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fire- place has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The burner should light. Set control knob to any heat level between HI and LO.
PROCEDURE

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient in- crease in firebox temperature.
Figure 36 - Natural Gas Pilot
Figure 37 -Propane/LP Gas Pilot
Shutting Off Fireplace 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance (if applicable) if service is to be performed.

Turn control knob clockwise to the PILOT position.
OPERATION
The thermostat used on this fireplace senses the room tempera- ture. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
AUTO/OFF/ON Switch


3. Press in and turn control knob clockwise to the OFF position (see Figure 39). 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 5. Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 39). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 8. Slightly push in and turn control knob counterclockwise

to the ON position. 9. Set flame adjustment knob to any level between HI and LO.

Figure 39 - Control Knob and Ignitor Button Location (Shown as Supplied - No Control Options)
Ignitor Electrode Pilot Burner
Ignitor Electrode Pilot Burner
Figure 40 - Propane/LP Gas Pilot
Figure 41 - Natural Gas Pilot
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 22)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-22-1.webp)
To Turn Off Gas To Appliance Manual Lighting Procedure Optional Hand-held Remote Operation
Flame Adjustment Knob Control Knob Selector Switch in Remote Position (Optional Remote Control) Shutting Off Fireplace 1. Turn control knob clockwise to the OFF position. 2. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Figure 42- Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Remote Operation
You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn control knob clockwise to the PILOT position. 2. If Using Optional Hand-Held Remote: Use remote con- trol manual OFF button.
Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 43).
TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.
![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 22)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-22-3.webp)
TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.
PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 21. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions, page 21.
Control Button Turns Burners On and Off
Figure 43 - On/Off Hand-Held Remote Control Unit (GHRCB)
THERMOSTAT SERIES (MODEL [C]GHRCTB)
REMOTE OPERATION
The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 44, page 23). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.
Manual Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press the MANU button to turn on the fireplace. 3. Press the POWER and LOCK buttons together to turn off the fireplace.
1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 42). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.
Auto (Thermostatic) Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press AUTO button to select this mode. 3. Set the desired room temperature by pressing the TEMP + or - buttons. 4. Press the POWER and LOCK buttons together to turn off the fireplace
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 23)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-23-1.webp)
Make sure the heater switch is on AUTO and set the temperature adjustment on wall thermostat to the desired setting. The ther- mostat has been electronically calibrated at the factory and requires no adjustment or leveling. Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. See installation instructions on page 18.
When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fire- place, the receiver ON/OFF/REMOTE switch should be in the OFF position.
Auto Shutoff Feature 1. If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode. 2. The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason can- not transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.
Make sure the heater switch is on AUTO. This wall switch works just like the conventional light switch. Flip the switch up for on and down for off.
BLOWER
Key Pad Lock Feature
This feature allows the user to lock/unlock the keypad on the hand- held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.
This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient in- crease in firebox temperature.
Digital Display Shows Temperature and Settings
Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting
Turns Burners On or Off
Decreases Room Temperature in AUTO Mode
Increases Room Temperature in AUTO Mode
Locks System to Prevent Accidental Ignition
Figure 44 - Thermostat Hand-Held Remote Control Unit ([C]GHRCTB)
Figure 45 - AUTO/OFF/ON Blower Switch
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Selects Auto Setting · AUTO/OFF/ON Switch

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 24)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-24-1.webp)
Pilot Flame Pattern Burner Flame Pattern CLEANING AND MAINTENANCE
Cleaning Burner Injector Holder and Pilot Air Inlet Hole
Check pilot flame pattern and burner flame patterns often.
Figure 46 shows a correct pilot flame pattern. Figure 47 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

Figure 46 - Correct Pilot Flame Pattern (Propane/LP Remote- Ready Shown)
Figure 47 - Incorrect Pilot Flame Pattern (Propane/LP Remote- Ready Shown)
BURNER FLAME PATTERN
Figure 48 shows a correct burner flame pattern. Figure 49 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have fireplace inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 50, page 25). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
Figure 48 - Correct Burner Flame Pattern
Figure 49 - Incorrect Burner Flame Pattern
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 25)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-25-1.webp)
25 25 CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)
WIRING DIAGRAM

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figures 51 or 52 depending on model). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Figure 50 - Injector Holder On Outlet Burner Tube
Figure 51 - Pilot Inlet Air Hole (Propane/LP Gas)
Figure 52 - Pilot Inlet Air Hole (Natural Gas)
Air Passageways • Use a vacuum cleaner or pressurized air to clean.
Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 26)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-26-1.webp)

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, pages 24 and 25) or re- place ODS/pilot assembly
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 27)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-27-1.webp)
POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Slight smoke or odor during initial operation
Fireplace produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
Moisture/condensation noticed on windows
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 28)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-28-1.webp)

POSSIBLE CAUSE
REMEDY
Remote does not function (Remote-Ready Models Only)
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 29)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-29-1.webp)
Thermostat Models: Thermostat Models: Remote-Ready Models: Remote-Ready Models: CDCFTP, VDCFTP, CDCFTN, VDCFTN, VDCFRP, FDCFRP VDCFRN, FDCFRN FDCFTP FDCFTN
Btu/Hr 17/26,000
Type Gas Propane/LP Gas Only Natural Gas Only Propane/LP Gas Only Natural Gas Only
Ignition Piezo
Manifold Pressure 8" W.C. 3.5" W.C. 8" W.C. 3.5" W.C.
Inlet Gas Pressure (in. of water) Maximum 14" 10.5" 14" 10.5" Minimum* 11" 5" 11" 5"
Dimensions, inches (HxWxD) Fireplace 25 7/8 x 26 13/16 x 15 5/16 25 7/8 x 26 13/16 x 15 5/16 25 7/8 x 26 13/16 x 15 5/16 25 7/8 x 26 13/16 x 15 5/16 (including hood and screws) * For purpose of input adjustment
REPLACEMENT PARTS
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical services web site at www.desatech.com.
Usually, we will ask you to return the part to the factory.
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 30)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-30-1.webp)

111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 31)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-31-1.webp)
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
NO. FDCF Models VDCF Models CDCF Models DESCRIPTION QTY.
1 110338-01CK 110338-01CK 110338-01CK Outer Casing Top 1 2 110334-01 110334-01 110334-01 Baffle 1 3 110343-01 110343-01 110343-01 Outer Casing 1 4 104281-02CK 104281-02CK 104281-02CK Firebox Hood 1 5 111136-01CK 111136-01CK 111136-01CK Firebox Top 1 6 111137-01CK 111137-01CK 111137-01CK Firebox Wrapper 1 7 110339-01CK 110339-01CK 110339-01CK Outer Base 1 8 102635-02 102635-02 102635-02 Front Left and Right Sides 2 9 103209-01 103209-01 103209-05 Extruded Louver 2 10 098304-01 098304-01 098304-01 Screw, PPH AB 10-16 x .38 8 11 M10908-2 M10908-2 M10908-2 Screw, SLTD HWH TPG 6-32 x .38 4 12 104313-01 104313-01 104313-01 Right Pin Hinge 1 13 104313-02 104313-02 104313-02 Left Pin Hinge 1 14 103295-05CK 103295-05CK 103295-03CK Screen Frame 1 15 111038-02 111038-02 111038-02 Remote/Blower Bracket 1 16 M11084-26 M11084-26 M11084-26 Screw, HEH AB 10-16 x .38 35 17 111633-01 111633-01 111633-01 Box Cover 1 18 111200-01 111200-01 111200-01 Support Bracket 1 19 099230-02 099230-02 099230-2 Screw, HWH SHLDR AB 10 x .63 14
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 32)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-32-1.webp)

111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 33)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-33-1.webp)
PARTS LIST MODELS FDCFTP, FDCFTN, VDCFTP, VDCFTN, CDCFTP and CDCFTN
THERMOSTAT MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
KEY FDCFTP FDCFTN NO. VDCFTP VDCFTN CDCFTP CDCFTN DESCRIPTION QTY.
1 111069-01 Dual Burner 1 2 099056-29 099056-34 099056-29 099056-34 Injector 1 3 104424-04 Outlet Tube 1 4 111124-01 Burner Retainer Spring 1 5 107486-01 107485-01 107486-01 107485-01 ODS Pilot 1 6 099387-09 Pilot Tube 1 7 098249-01 ODS Nut 2 8 M11084-38 Screw, HWH AB 8-18 x .38 2 9 M11084-26 Screw, HWH AB 10-16 x .38 10 10 111135-01CK Chamber Floor 1 11 097809-03 Male Fitting 1 12 098867-10 098867-14 098867-10 098867-14 Gas Regulator 1 13 108628-02 Inlet Tube 1 14 102394-02 Control Bracket 1 15 098522-13 098522-12 098522-13 098522-12 Thermostat Gas Valve 1 16 101381-01 Valve Cover with Piezo 1 17 101628-03 Flexible Connector 1 18 099211-01 Screw, HWH AB 10-16 x 2.50 2 19 098544-01 Thermobulb Clip 1 20 098271-10 Ignitor Cable 1 21 111138-01 111138-01 111138-02 111138-02 Log Set 1
901056-01 Brass Flare Adapter Fitting 1 103470-01 Hardware Pack 1 100563-01 Warning Plate 1 101054-01 Lighting Instruction Plate 1
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 34)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-34-1.webp)

111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 35)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-35-1.webp)
REMOTE-READY MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
KEY FDCFRP FDCFRN NO. VDCFRP VDCFRN DESCRIPTION QTY.
1 111069-01 111069-01 Dual Burner 1 2 099056-29 099056-34 Injector 1 3 103342-04 111195-07 Outlet Tube 1 4 111124-01 111124-01 Burner Retainer Spring 1 5 097809-02 097809-02 Male Fitting 1 6 103778-01 103779-01 ODS Pilot 1 7 099387-09 099387-12 Pilot Tube 1 8 098249-01 098249-01 ODS Nut 2 9 M11084-26 M11084-26 Screw, HWH AB 10-16 x .38 10 10 111135-01CK 111135-01CK Chamber Floor 1 11 110793-01 110793-01 Piezo Bracket 1 12 102445-01 102445-01 Piezo Ignitor with Palnut Fastener 1 13 101628-01 101628-01 Flexible Connector 1 14 098271-10 098271-10 Ignitor Cable 1 15 M12461-26 M12461-26 Screw, MX SLT WSR 10-32 x 3/8 4 16 111173-01 111173-01 Remote Valve Bracket 2 17 103781-02 103781-01 Gas Valve 1 18 101480-12 101480-12 ASM High Temp Wire 1 19 097809-02 097809-02 Male Fitting 1 20 111138-01 111138-01 Log Set 1 21 099918-02 Pilot Regulator 1 22 099387-14 Pilot Tube 1
901056-01 901056-01 Brass Flare Adapter Fitting 1 103470-01 103470-01 Hardware Pack 1 100563-01 100563-01 Warning Plate 1 103877-01 103877-01 Lightting Instruction Plate 1
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 36)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-36-1.webp)

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA Heating Prod- ucts at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
CABINET MANTEL WITH BASE CMA204F Series - French Walnut CMA205U Series - Unfinished CMA206F Series - Cherry
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
For all models. A mantel and hearth base offers compact styling and completes the fireplace look. Complete assembly instructions in- cluded. Three-sided brass trim kit included.

For all models. Optional four-sided brass trim kit for recessed built- in installations (when unit is raised off of the floor). Provides a finished appearance by covering rough edges of wall opening.
CORNER MANTEL WITH FULL HEARTH BASE CMA208F Series - French Walnut CMA209U Series - Unfinished
For all models. Optional three-sided brass trim kit for custom and recessed installations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening. Included with all mantels.
For all models. Space-saving mantel and hearth base corner design features clean, classic lines. Available in french walnut finish or an unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.
For all models. Provides better heat distribution. Makes fireplace more efficient. Automatically turns off and on as needed.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 37)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-37-1.webp)

For all remote-ready models. Allows the fireplace to be operated in a manually or thermostatically controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair.
CABINET MANTEL AND FULL HEARTH BASE GMC80F Series - Oak Finished CMA200F Series - Oak Finished GMC81U Series - Unfinished Birch CMA201U Series - Unfinished Birch GMC82F Series - Cherry Finished Birch CMA202F Series - Cherry Finished Birch Glow) For all models. Mantel features columns, moldings, fluting and medallion. Dimensions (WxHxD): 56" x 50" x 24"
For all remote-ready models. Allows the fireplace to be turned on and off by using a hand-held remote control.
INFORMATION VIDEO - 108917-01
For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.
WALL-MOUNT THERMOSTAT SWITCH GWMT1 (Not Shown)
For all models. Creates the sound of a real burning fire.
For all remote-ready models. The desired comfort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pilot to the heat setting selected.
For all remote-ready models. Allows the fireplace to be turned on and off with a wall switch.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 38)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-38-1.webp)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

39 39 • ACCESSORIES
In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA Heating Products:
❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other
❍ 100,000 to 250,000 ❍ Over 250,000
❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other
❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other
❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over
Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson’s Recommendation Friend/Relative’s Recommendation Portability Quiet Operation
Not Important Somewhat Important Very Important
❍
❍
❍
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
![Page 40 of the Desa FDCFRN user manual — ON/OFF SERIES (MODEL [C]GHRCB)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/page-40.webp?w=400)
![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 40)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-40-1.webp)
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 40)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-40-2.webp)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Postage Required

![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 41)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-41-1.webp)
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
![Page 42 of the Desa FDCFRN user manual — ON/OFF SERIES (MODEL [C]GHRCB)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/page-42.webp?w=400)
![Desa FDCFRN — ON/OFF SERIES (MODEL [C]GHRCB) diagram (page 42)](/cdn/reader/14/149e7b577d9f8a2f06393991a5eaa4d1be52431823d553d756998de28bb369cb/images/fig-42-1.webp)
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
111244-01 Rev. A 04/03 NOT A UPC
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
111244 01