NATURAL GAS MODEL DVF34 PROPANE/LP GAS MODEL DVF34P
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
— Installation and service must be performed by a qualified in- staller, service agency, or the gas supplier.
— This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Save this manual for future reference.

10. Have venting system inspected annu- ally by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Mainte- nance, page 26. 11. Keep the area around your fireplace clear of combustible materials, gaso- line, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire- place nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANS/NFPA 70, or the Cana- dian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combus- tion and ventilation air in any way. Pro- vide adequate clearances around air openings into the combustion chamber along with adequate accessibility clear- ance for servicing and proper operation. 16. Do not install fireplace directly on car- peting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel ex- tending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to ar- range for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this fireplace. 20. Do not operate fireplace with glass door removed, cracked, or broken.
This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leakage can occur.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and ser- viced by a qualified service person. Some people are more affected by carbon monox- ide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
2 106424

PRODUCT IDENTIFICATION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada).
Vent Opening Nailing Flange Standoff
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
This direct-vent fireplace is clean burning and vents easily through outside walls or vertically using outside air for combustion. Heat is generated by both realistic flames and glowing embers. When used without the blower accessory, the fireplace requires no electricity making it ideal for emergency backup heat.
This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.
Blower Adjustment (Optional Installation) ON/OFF Remote Switch (Optional Installation)
Figure 1 - FMI Direct-Vent Fireplace DVF Series
Chase - A boxlike enclosure to protect venting from the elements when the venting run is on the outside of a structure.
Mastic - A pliable sealant for use around the vent terminal.
Snorkel Termination - A box that raises the horizontal termination above ground level clearances.
Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather.
Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding.
Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling.



Minimum clearances to combustibles for the fireplace are as follows:
Back, and sides 0"/mm Perpendicular walls 6" (152mm) Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) Top of Standoffs 0"/mm
Determine the safest and most efficient loca- tion for your FMI direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a loca- tion where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact loca- tion for your fireplace.
See General Venting on pages 5 and 6 for specific venting clearances.
Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clear- ances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fire- place must set on a metal or wood panel extending the full width and depth of the fireplace.
When deciding the location of your fire- place, follow these rules: 1. Do not connect this fireplace to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance. 2. Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies. 3. Proper clearances must be maintained. 4. If your fireplace is to be installed di- rectly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.
Figure 5 - Framing Clearances for Typical Fireplace Installation
See Accessories on page 34 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper installation height. You can install noncombustible man- tels at any height above the fireplace. Note: Noncombustible mantels may discolor!


Figure 2 - Common Fireplace Locations
20" Vertical Termination 19" Horizontal Termination
Figure 4 - Framing Clearances for Installation Against an Exterior Wall
Figure 3 - Fireplace Bottom Dimensions
4 106424

GENERAL VENTING
These models are approved for use with FMI 7" direct-vent pipe components and terminations.
9 1/4" 41"
12 5/8"
34 3/8"
35 1/16"
Figure 6 - Framing Clearances for Corner Installation
B
D
E
F
G
LOCATION OF VENT TERMINATION
Top of Louver Opening
When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 8, page 6. You will avoid extra framing by positioning your fireplace against an already existing framing mem- ber. The sides of the fireplace may be posi- tioned directly against combustible walls.
*Check with local codes or with the current CAN/CGA B149 [.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54.
Figure 7 - Clearances for Combustible Mantels



TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony
I = clearance to service regulator vent outlet [*72 inches (1829mm)
[*12 inches (305mm) minimum] B = clearance to window or door that may be opened
minimum] J = clearance to non-mechanical air supply inlet to building or the
[12 inches (305mm) minimum] C = clearance to permanently closed window [minimum 12 inches
combustion air inlet to any other fireplace [*12 inches (305mm) minimum] K = clearance to a mechanical air supply inlet [*72 inches (1829mm)
(305mm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal
minimum] L = † clearance above paved side-walk or a paved driveway located on
within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum] E = clearance to unventilated soffit [12 inches (305mm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within
public property [*84 inches (2133mm) minimum] M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡] N = clearance above a roof shall extend a minimum of 24 inches (610mm)
above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)
36 inches (914mm) horizontally from the center-line of the regulator
† vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1 Note: Local codes or regulations may require different clearances
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Outside Corner Recessed Location


Balcony with No Side Wall
Balcony with Perpendicular Side Wall
recessed location D = Minimum width for back wall of
recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in
Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm)
recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)
G = Combustible 24" (610mm)
Figure 8 - Minimum Clearances for Vent Terminations
Inside Corner · Noncombustible 18" (457mm) · 6 106424

For Vertical Termination: Measure the dis- tance from the fireplace flue outlet to the ceiling. Add the ceiling thickness, the verti- cal rise in an attic or second story, and allow for sufficient vent height above the roofline. You may use one or two 90° elbows in this vent configuration. See Vertical Termination Configurations on pages 13 and 14.
For two-story applications, firestops are re- quired at each floor level. If an offset is needed in the attic, additional pipe and el- bows will be required.
WARNING: Seal all vent con- nections. Seal only the outer pipe connections with high temperature silicone (600°F/316° C). Before join- ing elbows and pipes, apply a bead of high temperature silicone seal- ant (GE RTV 106/Loctite RTV 81585) to the male end of the elbow or pipe. High temperature silicone must also be used to re-seal any connections after maintenance to venting system.
You may use a chase with a vent termination with exposed pipe on the exterior of the house. See Installing Vent System in a Chase, below.
WARNING: Horizontal sec- tions of this vent system require a minimum clearance of 2" from the top of the pipe and 1" minimum to the sides and bottom. 1 1/2" clear- ance is required where termina- tion penetrates a combustible wall. Vertical sections of this system require a minimum of 1" clear- ance to combustible materials on all sides of the pipe.
Your FMI direct-vent fireplace has been tested for a minimum 3' rise with a maximum 10" wall thickness. The maximum horizontal run is 20' with 8' vertical rise (see Installation for Horizontal Termination, page 8). The maxi- mum vertical run is 30' (see Installation for Vertical Termination, page 12).
It is very important that the venting system maintain its balance between the combus- tion air intake and the flue gas exhaust. Certain limitations apply to vent configura- tions and must be strictly followed.
INSTALLATION PRECAUTIONS
Consult local building codes before begin- ning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.
Installing Vent System in a Chase A chase is a vertical boxlike structure built to enclose venting that runs along the out- side of a building. A chase is not required for such venting.
It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
For Horizontal Termination: Select the amount of vertical rise desired. The horizon- tal run of venting must have 1/4" rise for every 12" of run towards the termination.
You may use one or two 90° elbows in this vent configuration. See Horizontal Termina- tion Configurations on pages 10 and 11.
After framing the chase (see Framing and Finishing on page 4) install the vent system by following the installation instructions.
Continued · 7 106424

INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.
Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 9 and 10). Follow the same installation procedures as used for standard horizon- tal terminations. If installing the snor- kel termination below grade (basement applications), you must provide proper drainage to prevent water from entering the snorkel termination (see Figure 10). Do not back fill around the snorkel ter- mination. 2. Rigid vent pipes and fittings have spe- cial twist-lock connections. Assemble the desired combination of pipe and el- bows to the appliance adaptor with pipe seams oriented towards the wall or floor. Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fit- tings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 11, page 9. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.
Figure 9 - Snorkel Termination
Figure 10 - Snorkel Termination with Drainage Pipe

4. Apply a bead of non-hardening mastic around the outside edge of the vent cap. Position the vent cap in the center of the 7 1/2" or 10" hole on the exterior wall with the arrow on the vent cap pointing up. Insure proper clearance of 1" to combustibles is maintained. At- tach the vent cap with four wood screws supplied (see Figure 13). Note: Re- place the wood screws with appropri- ate fasteners for stucco, brick, concrete, or other types of siding.
6. Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1 1/4". Apply silicone to the outer pipe connection. Fasten all vent connections with screws provided. Refer to Fireplace Installation on page 16 for instructions on securing unit to framing or floor. 7. Slide the wall thimble against the inte- rior wall surface and attach with screws provided (see Figure 15).
3. Attach vent pipe assembly to the fireplace. Set fireplace in front of it’s per- manent location to insure minimum clear- ances. Mark the wall for a 10" square hole (for noncombustible material such as masonry block or concrete, a 7 1/2" diam- eter hole is acceptable). See Figure 12. The center of the hole should line up with the center-line of the horizontal rigid vent pipe. Cut a 10"x10" (254mm x 254mm) square hole through combustible exterior wall (7 1/2" [190mm] diameter hole if non- combustible). Frame as necessary (see Figure 12).
Cut Vinyl Siding Away to Fit Standoff
For vinyl siding use vinyl siding stand- offs between vent cap and exterior wall. The vinyl siding standoff prevents ex- cessive heat from melting the vinyl sid- ing material. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff in- stead of the vent cap assembly. Use wood screws provided to attach the standoff. See Figure 14. 5. Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap (see Figure 15).
Apply Mastic to All Four Sides
Figure 14 - Installing Vinyl Siding Standoff
Figure 11 - Rigid Vent Pipe Connections
Apply Mastic to All Four Sides
Vent Opening Combustible Wall
Vent Opening Noncombustible Wall
Figure 13 - Installing Horizontal Vent Cap
Vent Cap (Horizontal Termination)
7 1/2" (190mm)
Figure 15 - Connecting Vent Cap with Horizontal Vent Pipe
Figure 12 - Vent Opening Requirements


FD60 60˚ Starter/ Adapter Required

Figures 16 through 19 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.
Vertical (V) Horizontal (H)
37" min. 10" max.
Figure 16 - Horizontal Termination Configuration for Rigid Venting

44" min. 29" max. (30° and 90° only, no vertical pipe)
55" min. 41" max. (30° elbow, 1' vertical pipe, 90° elbow)
67" min. 60" max. 79" min. 84" max. 96" min. 20' max.
Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow
Horizontal Venting · 10 106424


Vertical (V) Horizontal (H1) Horizontal (H1) +
5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max.
Figure 18 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows
5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max.
Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace
11 106424


Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in Figure 12 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceil- ing or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 21). 2. Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7. Be sure all pipe and elbow connections are fully twist- locked (see Figure 11, page 9). 3. Cut a hole in the roof using the locating hole as a center point. (Cover any ex- posed open vent pipes before cutting hole in roof.) The 10"x10" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combus- tible materials. Frame the opening as shown in Figure 12 on page 9.
4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 20). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less re- striction to the flow of the flue gases and intake air. 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 20. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the mini- mum building code requirements de- scribed in Figure 8 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs, and other similar fac- tors may cause poor draft or down-draft- ing in high winds. Increasing the vent height may solve this problem. 7. Twist-lock the vent cap onto the last section of vent pipe and seal outer pipe connection with high temperature sili- cone sealant as specified in the second warning statement on page 7. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclo- sure with standard construction material. Make sure and meet the minimum allowable clear- ances to combustibles. Do not fill any of the required air spaces with insulation.
INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical vent- ing will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 20) to avoid cutting load bearing members. Note: Pay special attention to these installation instruc- tions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum verti- cal rise of the venting system and any maximum horizontal offset limitations. Offsets must fall within the parameters shown in Figure 8 on page 6. 2. Set the fireplace in desired location. Drop a plumb line down from the ceil- ing to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceil- ing. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.
If area above is a room, install firestop above framed hole.

Cathedral Ceiling Installation 1. Remove shingles or other roof cover- ing as necessary to cut the rectangular hole for the support box. Mark the out- line of the cathedral ceiling support box on the roof sheathing using the locat- ing hole as a center point. 2. Cut the hole 1/8" larger than the sup- port box outline (see Figure 22, page 13).
If area above is not a room, install firestop below framed hole.
Figure 20 - Offset with Wall Strap and 45° Elbows
Figure 21 - Installing Firestop
Roof Flashing · Wall Strap · 12 106424

Figures 24 through 27 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.
3. Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 22). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing. 4. Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 23). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box. 5. Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1) +
Horizontal (H2)
5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max.
FD60 60˚ Starter/ Adapter Required
20' max. 8' max.
Cathedral ceiling support box
Figure 24 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two Horizontal Runs
2" minimum below finished ceiling
FD60 60˚ Starter/ Adapter Required
Cut hole 1/8" larger than support box when projected onto roofline
Figure 22 - Cathedral Ceiling Support Box Installation
Venting with One 90° Elbow
Vertical (V) Horizontal (H)
5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max.
20' max. 8' max.
Non-hardening Mastic under all edges of support box before nailing Figure 23 - Installed Cathedral Ceiling Support Box
Figure 25 - Vertical Rigid Venting Configuration Using One 90° Elbow
Level · Continued · 13 106424


Figure 27 - Vertical Rigid Venting Configuration With No Horizontal Run
5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max.
Figure 26 - Vertical Rigid Venting Configuration Using Two 90° Elbows
14 106424

PARTS LISTS FOR VENTING KITS AND COMPONENTS FMI Rigid Venting Number Description FD30 30˚ Starter/Adapter (6 5/8" to 7") 6 per box FD60 60˚ Starter/Adaptor (6 5/8" to 7") 6 per box F7030 7" to 12" Adjustable pipe length
Number Description 01825 36" Snorkel termination 01826 14" Snorkel termination 01827 Termination/high rise/horizontal 01828 Wall strap 6 per box 01829 Storm collar 6 per box 01797 Vertical round high wind termination 01799 Horizontal square high wind termination
Your FMI direct-vent fireplace has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities. Consult your local gas company to help de- termine the proper orifice for your location. For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Service Department at 1-800-DESA- LOG (1-800-337-2564).
6 per box D1031 7” to 12” Adjustable pipe length
1 per box D3050 Vertical restrictor
6 per box 01806 Basic vertical kit Adjustable flashing - storm collar, vertical cap 01807 48" Pipe length 6 per box 01808 36" Pipe length 6 per box 01809 24" Pipe length 6 per box 01810 12" Pipe length 6 per box 01811 6" Pipe length 6 per box 01812 17" to 24" adjustable pipe length 6 per box 01813 45˚ Elbow 6 per box 01814 90˚ Elbow 6 per box 01817 Wall firestop 6 per box 01818 Adjustable flashing (0/12-8/12) 6 per box 01819 Steep pitch flashing (12/12 6 per box 01820 Vinyl/Stucco siding standoff 01821 Firestop plate 6 per box 01822 Vertical termination cap 01823 Horizontal round termination cap
15 106424


Installing GA3700/DA3610TA Blowers
FIREPLACE INSTALLATION
Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See re- tailer where you purchased the fireplace for proper fireplace according to your gas type.
IMPORTANT: For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 29 through 32, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines. 1. Open lower louver panel or remove for easier access. 2. Place the blower against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Figure 29, page 17). Using the two screws provided, mount blower and tighten screws securely. Note: For DA3610TA, make sure the thermal switch is comfortably under the back of the firebox as shown in Figure 30, page 17. 3. Be sure to securely attach all wire ter- minals to terminals on blower motor (and thermal switch where applicable) and that the screw retaining the green ground wire is tight. 4. Remove screws securing the plate to the bottom of the firebox and set aside. 5. Place speed control against back of this plate and push the plastic control shaft through opening (see Figure 31, page 17). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the plate. Place control knob provided onto shaft (see Figure 31, page 17). 7. Replace plate containing switch and tighten screws securely.
NOTICE: This fireplace is in- tended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat through- out the house. In the event of a power outage, you can use this fireplace as a heat source.
When installing the DA3610TA thermo- statically-controlled blower accessory, you must first secure the thermal switch to the blower. 1. Remove the two hex head screws on the blower assembly as shown in Figure 28. 2. Place the green wire between the bot- tom hole on the thermal switch bracket and the bottom hole on the blower as- sembly. Insert one of the hex screws into all three pieces and tighten. 3. Insert the top screw through the ther- mal switch bracket and into the blower assembly. Tighten screw. 4. Connect the blue wire on the blower assembly to the right side of the ther- mal switch. 5. Connect the black wire to the left side of the thermal switch.
Note: Your fireplace is designed to be used in zero clearance installations. Wall or fram- ing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 4.

Place the fireplace into position and shim with noncombustible material if needed. Nail the side flanges to the framing to secure the unit in place. There are two floor brack- ets included with each unit. Use these as an alternative method of securing the fireplace.
Figure 28 - Attaching Thermal Switch to DA3610TA Thermostatically-Controlled Blower Accessory

as a freestanding unit with an ac- cessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. In- stall one plastic bushing provided into the 1 1/2" hole in the outer cas- ing through which the power cord will exit. Install the second plastic bushing provided into the floor sup- port bracket if exiting through the right side (see Figure 32). Route power cord through (both) plastic bushing(s) and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox. b. If your fireplace system installation
Firebox Bottom Firebox Back
is recessed and/or pre-wired, a qualified installer must make all elec- trical connections for the outlet kit included with the fireplace.
Figure 30 - Locating Thermal Switch Against Back of Firebox
Lower Rear Wall of Firebox Wrapper
Figure 31 - Attaching Speed Control to Firebox
Blower Speed Control Bracket
Figure 29 - Mounting Blower to Firebox
Figure 32 - Installing Plastic Bushing and Wiring Diagram Sticker

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 34).
Propane/ LP Supply Tank
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 34. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.
Figure 33 - External Regulator with Vent Pointing Down (Propane/LP Only)
CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the CSA design-certified equipment shutoff valve from your retailer.
Natural - From Gas Meter (5" W.C. to 10.5" W.C. Pressure )
For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 33. Pointing the vent down protects it from freezing rain or sleet.
Propane/LP - From External Regulator (11" W.C. to 14" W.C. Pressure)
Figure 34 - Gas Connection * The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer.

Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was con- nected. 3. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 4. Check all joints of gas supply piping system. Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Installation Items Needed
To Gas Supply (Natural)
To External Regulator (Propane/LP)
Flexible Gas Line from Equipment Shutoff Valve Provided by Installer
Figure 35 - Attaching Flexible Gas Line to Control Valve


Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 36). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 3. Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 37 for pro- pane/LP or Figure 38 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Fig- ure 36). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 37 for propane/LP or Figure 38 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fire- place, pages 24 and 25). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 24).
Figure 37 - Checking Gas Joints for Propane/LP Gas Fireplace

Figure 38 - Checking Gas Joints for Natural Gas Fireplace
20 106424

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of re- mote control unit. 2. Attach terminal wires to a 9-volt alka- line battery (not included). Place bat- tery into the battery housing. 3. Replace battery cover onto remote con- trol unit.
You must remove glass door to install optional brick liners, logs, lava rock, and ember material.
Terminal Wires Remote Control Unit
1. Open bottom louver and locate the switch bracket on the left. 2. Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver. 3. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip (see Figure 39). 4. Attach the terminal wires to the battery. 5. Connect wire leads to TH and THTP to control valve (see Figure 40). 6. Replace the switch bracket.
Figure 41 - Installing Alkaline Battery in Hand-Held Remote Control Unit
Terminal Wires Battery Clip
1. Connect one terminal of the provided wire for the wall switch to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 40. If wires are not connected as shown the switch will not work. 2. Route the wire through openings pro- vided on the sides of the fireplace to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall.
Figure 42 - Removing Top Louver Panel
Figure 39 - Attaching Alkaline Battery to Receiver
Lower Bracket for Glass Door Assembly
Figure 40 - Connecting Remote Accessories to Control Valve
Continued Figure 43 - Removing/Replacing Glass Door


This fireplace comes with a set of two magnetic decorative brass strips. Before attaching strips to fireplace, remove plastic film from brass pieces. After installing the door, attach these strips to the top and bot- tom of the glass door frame.

This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, page 34.
Figure 44 - Installing Left Side Brick Panel
1. Remove glass door. See Removing/Re- placing Glass Door, pages 21. 2. If installing brick liner in new fireplace, go to step 3. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material. 3. Install left side brick panel first by slid- ing it between the grate and the side of the firebox (see Figure 44). 4. Slide the left retainer bracket against the left side brick panel. Loosely se- cure the bracket screw. This secures the left side brick panel. 5. Install the right brick panel using the same method described in step 3. 6. Slide the right retainer bracket against the right side brick panel. Loosely se- cure the bracket screw. This secures the right side brick panel. 7. Install rear brick panel. Rest bottom edge of panel on back edge of grate (see Figure 45).

Figure 45 - Installing Rear Brick Panel and Retainer Brackets
Rear Brick Panel · 22 106424

This will create the glowing ember ap- pearance as the flame touches the em- ber material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided. 8. Replace the glass door. See Removing/ Replacing Glass Door, page 21.
Figure 48 - Installing Log No. 3
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace. 1. Remove glass door. See Removing/Re- placing Glass Door, page 21. 2. Place log #1 (back log) on top of grate. Make sure the notches in the bottom of the log fit over the grate (see Figure 46). 3. Rest log #2 (large front log) on the pins on the front part of the grate (see Figure 47). 4. Place log #3 (left piece) onto the front left part of the grate. Make sure it is seated properly over the prong of the grate as shown in Figure 48. 5. Place log #4 (right piece) onto the front right part of the grate making sure the notches fit over the prong of the grate (see Figure 49). 6. Place lava rock along sides and front of inside of firebox bottom. It is not necessary to use all of the lava rock provided. 7. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 50).
Figure 46 - Installing Log No. 1
Figure 49 - Installing Log No. 4
Figure 50 - Placing Ember Material on Burner
Figure 47- Installing Log No. 2
Ember Material · 23 106424

1. STOP! Read the safety information in column one. 2. Open lower louver panel. 3. Disconnect the wire that runs from TH to TPTH of valve. 4. Turn off all electric power to the fireplace. 5. Push in gas control knob slightly and turn clockwise to “OFF”. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column one. If you don't smell gas, go to the next step. 7. The pilot is located by the main burner and should not require ac- cessing for lighting. 8. Turn gas control knob counterclock- wise to “PILOT”.
LIGHTING
TO TURN OFF GAS
TO APPLIANCE 1. Open lower louver panel. 2a. Disconnect wire from TH and TPTH on valve. 2b. If Using Optional ON/OFF Switch: Turn ON/OFF switch to “OFF”. 2c. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery. 3. Turn off all electrical power to the appliance if service is to be performed. 4. Push in gas control knob slightly and turn clockwise to “OFF”. 5. Close lower louver panel.
You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn gas control knob clockwise
to the PILOT position. 2. Set selector switch in the OFF position.
PROCEDURE
Gas Control Knob Variable Control Knob
O
T
O
H
F
N
O
F
O
Figure 51 - Control Valve
Piezo Ignitor · 24 106424

INSPECTING BURNERS
ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
HELD REMOTE
The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.
Both the GA3700 manual blower and the DA3610TA thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 53. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.
1. After lighting, let pilot flame burn for about one minute. Turn gas control knob on the control valve to ON posi- tion. Turn variable control knob any- where between HI and LO. Slide the selector switch to the REMOTE po- sition. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote con- trol unit. IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation. 2. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the gas control knob on the heater to the OFF position.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
WALL MOUNTED
SWITCH Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.
Figure 53 - Pilot Assembly
Blower Control Knob (Optional Accessory)
O
N
REMOTE
T
O
F
F
O
O
H
OFF
P
ON
Gas Control Knob in On Position
Selector Switch in Remote Position
Figure 52 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation


Use only the glass door replacement in- tended for this fireplace (see Replacement Parts, page 30 for detail on ordering). No substitutions may be made. See Removing/ Replacing Glass Door, page 21 for instruc- tions for replacing glass door. BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.
Figure 54 shows a typical flame pattern for DVF34(P) models.
Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive household cleaner and warm water after the first two weeks of operation. There- after, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 21 of this manual when removing glass door for cleaning.
Figure 54 - Typical Flame Pattern

CLEANING AND MAINTENANCE
Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person. 2. Remove the vent cap and shine a flash- light into the vent. Remove any foreign material. 3. Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many el- bows, or exterior portions of the sys- tem being exposed to cold weather. 4. Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 21). Vacuum all glass pieces with a shop vac.
26 106424

TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at pilot
When ignitor button is pressed, there is spark at pilot but no ignition
Pilot lights but flame goes out when control knob is released
B) Clean pilot (see Cleaning and Maintenance, page 26) or replace pilot assembly
www.desatech.com Continued
27 106424

POSSIBLE CAUSE
REMEDY
Burner does not light after pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Heater produces a whistling noise when burner is lit
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
Remote does not function
Delayed ignition burner · Glass soots · 28 106424

POSSIBLE CAUSE
REMEDY
Fireplace produces unwanted odors
Fireplace shuts off in use
1. Fireplace has been tested for up to 40mph winds. However, extreme con- ditions may occur. See Lighting Instruc- tions on page 24 2. Contact local propane/LP or natural gas company 3. Clean pilot (see Cleaning and Mainte- nance, page 26) 4. Locate and correct all leaks (see Check- ing Gas Connections, pages 19 and 20) 5. Horizontal vent termination should slope down only enough to prevent any water from entering the unit. The maximum downward slope of the vent termination is 1/4" for any horizontal run 6. Tighten glass
Gas odor even when control knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace
29 106424

WIRING DIAGRAM
Variable Fan Switch Fan Switch
110/115 V.A.C.
Figure 55 - Blower Wiring Diagram for Thermostat-Controlled Models
TECHNICAL SERVICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
You can also visit DESA International’s technical service web site at www.desatech.com
If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier.

Btu 15,000/21,000 Btu/h 16,000/20,000 Btu/h
Gas Type Natural Propane/LP
Manifold Pressure 3.5" w.c. 10.0" w.c.
Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c.
Fireplace (Actual size of firebox. Measurements do not 32 3/16" x 34 3/8" x 18 1/2" 32 3/16" x 34 3/8" x 18 1/2" include nailing flanges or 817 x 873 x 470mm 817 x 873 x 470mm stand-offs).
Carton 37" x 40" x 21" 37" x 40" x 21" 940 x 1016 x 533mm 940 x 1016 x 533mm
Fireplace 123 lbs/56 kg 123 lbs/56 kg Shipping 126 lbs/57 kg 126 lbs/57 kg



32 106424

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.
KEY NO. PART NUMBER DESCRIPTION QTY.
KEY NO. PART NUMBER DESCRIPTION QTY.
1 104445-01 Top Outer Casing-34" 1 2 105278-01 Outer Casing-34" 1 3 105297-01 Bottom Outer Casing 1 4 104479-10BR Firebox Assembly 1 5 M11084-26 Screw, Hex 50 6 M11084-46 Screw, Hex 8 7 105394-01 Louver, Extruded 2 8 104443-01 Firebox Support, Right 1 9 104486-01 Firebox Support, Left 1 10 104482-01 Switch Bracket 1 11 104483-01 Floor Mounting Bracket 2 12 104491-01 Relief Cover 1 13 104518-01 Relief Cover Gasket 1 14 104527-01 Relief Springs 2 15 104528-01 Relief Washer 2 16 104537-01 Valve Bracket 1 17 104496-01 Sit Valve, Natural 1 104496-02 Sit Valve, Propane/LP 18 104497-01 Sit Pilot, Natural 1 104497-02 Sit Pilot, Propane/LP 19 104498-01 Thermocouple 1 20 104499-01 Thermopile 1 21 104500-01 Piezo Ignitor 1 22 104501-01 Ignitor Bracket 1 23 104502-01 Ignitor Screw 1 24 104503-01 Ignitor Wire 1 25 104504-01 Burner, Natural 1 104504-02 Burner, Propane/LP 26 104506-01 Orifice, Natural 1 104506-02 Orifice, Propane/LP
27 104507-01 Brass Elbow 1 28 104508-01 Brass Fitting 2 29 104509-01 Aluminum Tubing Assy 1 30 104510-01 Pilot Tubing Assembly 1 31 107166-01 Log Set 1 31-1 107459-01 Rear Log 1 31-2 105772-02 Front Log 1 31-3 105772-03 Left Piece 1 31-4 105772-04 Right Piece 1 32 M10908-2 Screw 6 33 M12461-65 Screw 3 34 H5C4-20B Bolt 2 35 M12461-26 Screw 4 36 104555-02CJ Grate Assembly 1 37 105775-15 Glass Door Assembly 1 38 104615-02 Insulation 1 39 105450-01CK Front Assembly 1 40 104313-01 Hinge, Pin-Left 1 41 104313-02 Hinge, Pin-Right 1 42 104954-01 Screw 1 43 104963-01 Washer 3 44 104955-01 Nut 3 45 105575-01 Wire Harness 3 46 NTC-4C Lock Nut 1 47 105325-01 Burner Baffle 1
GA6060 Lava Rock 104529-01 Ember Material
33 106424


Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of this manual.
Optional three sided brass trim kit covers unfinished edges around fireplace. Provides a finished appearance with the class of brass.

Manual-variable control blower accessory for the DVF Series fireplaces.
These louvers will give your fireplace an elegant look and allows you to customize your fireplace. They easily replace the stan- dard black louvers by screwing into place.
These strips have a magnetic backing which makes installation and removal quick and easy. They are designed to go at the top and bottom of the glass door on DVFH units. Note: Remove the plastic film covering on strips before installing on fireplace.
CABINET MANTEL GM101UC Series - Unfinished GM106FC Series - Oak Finished with Medium Stain
Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.
Shown with optional base and laminate hearth and mantel trim accessories.
Dimensions (WxHxD): 56 3/4" x 48 3/4" x 22 3/4"
This brick liner adds a touch of style to your direct-vent fireplace and comes with easy to follow instructions for installation.
For all models. Allows the heater to be manually turned on and off.
HARDWOOD HEARTH BASE G3001U Series - Unfinished G3006F Series - Oak Finished with Medium Stain
For all models. Allows the heater to be turned on and off conveniently.
The hearth base creates a handsome riser for the fireplace (cannot be used with corner mantel).
34 106424


Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
106424-01 Rev. A 04/00 NOT A UPC