Instruction/ maintenance manual of the product CGN18RA Desa
Go to page of 32
Save this manual for future reference. VENT -FREE INFR ARED NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Models: CGN18RA and CGN30D WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 101826 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ...................
3 101826 SAFETY INFORMA TION Continued WARNING ICON G001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only natural gas.
4 101826 PRODUCT IDENTIFICA TION GRH/PV 006A COMFORT GLOW PLAQUE FRONT-NON THERMO Control Knob Burners Heater Cabinet Front Panel Grill Guard LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.
5 101826 Unconfined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space).
6 101826 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 101826 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12&.
8 101826 AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.
9 101826 IMPORT ANT : V ent-free heaters add moisture to the air . Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and V entilation, pages 5 through 8.
10 101826 Minimum From Sides Of Heater 36" 3" FLOOR CEILING Minimum Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material 8" Left Side Right Side Figure 4 - Mounting C.
11 101826 INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel. Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel.
12 101826 Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level. 2. Mark screw locations on wall (see Figure 7). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.
13 101826 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. INST ALLING T O W ALL Continued Figure 9 - Popping Open Anchor Wings For Thin Walls 5.
14 101826 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. Install sediment trap in supply line as shown in Figure 12, page 15. Locate sediment trap where it is within reach for cleaning.
15 101826 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT Plug Tap Test Gauge Connection * Sed.
16 101826 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 13).
17 101826 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
18 101826 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step. 5. Press in control knob.
19 101826 TO SELECT HEA TING LEVEL 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW, MEDIUM, or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.
20 101826 Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.
21 101826 INSPECTING BURNER Continued BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern.
22 101826 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER ORIFICE • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture.
23 101826 TROUBLE- SHOOTING Continued OBSERVED PROBLEM When control knob is pressed in and turned to the PILOT/IGN position, there is spark at ODS/pilot but no ignition ODS/pilot lights but flame goes out when control knob is released POSSIBLE CAUSE 1.
24 101826 TROUBLE- SHOOTING Continued OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is lit or shut off REMEDY 1.
25 101826 TROUBLE- SHOOTING Continued If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
26 101826 SPECIFICA TIONS CGN18RA CGN30D BTU (Variable) 6,600/12,000/18,000 6,600/18,000/30,000 Type Gas Natural Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 6" W.C. 6" W.C. Inlet Gas Pressure (in. of water) Maximum 10.5" 10.
27 101826 P ARTS CENTRALS These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap.
28 101826 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGN18RA 13-17 13-16 ODS/PILOT BURNER ASSEMBLY 1 2 3 11 6 4 8 5 6 7 12 13 9 10 14 A B C 13-1 13-2 13-3 13-10 13-4 13-5 13-6 13-7 13-8 .
29 101826 P ARTS LIST Model CGN18RA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
30 101826 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGN30D 13-17 13-16 ODS/PILOT BURNER ASSEMBLY E D C 13-1 13-2 13-3 13-9 13-4 13-5 13-7 13-6 13-18 13-8 13-10 13-14 13-13 13-12 13-15 1.
31 101826 P ARTS LIST Model CGN30D This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
101826-01 REV. D 11/96 KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice.
An important point after buying a device Desa CGN18RA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa CGN18RA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa CGN18RA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa CGN18RA you will learn all the available features of the product, as well as information on its operation. The information that you get Desa CGN18RA will certainly help you make a decision on the purchase.
If you already are a holder of Desa CGN18RA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa CGN18RA.
However, one of the most important roles played by the user manual is to help in solving problems with Desa CGN18RA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa CGN18RA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center