PROPANE/LP GAS MODELS (V)VC42P AND CGCDV42PR SERIES
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com
Patent Pending

Table of Contents Safety Information 2 Product Identification 4 Local Codes 5 Product Features 5 Pre-Installation Preparation 5 Location of Termination Cap 8 Venting Installation Instructions 9 Fireplace Installation 19 Operating Fireplace 27 Inspecting Burners 30
Cleaning and Maintenance 31 Troubleshooting 33 Replacement Parts 37 Service Hints 37 Technical Service 37 Specifications 37 Illustrated Parts Breakdown and Parts List 38 Accessories 42 Warranty Information Back Cover
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
This appliance may be in stalled in an aftermarket,* permanently located, manufactured (mobile) home, where not prohib ited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

This fireplace must be installed by a qualified (cer tified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combus tion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected and sealed, carbon monoxide leakage (spillage) can occur.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the appliance.
Natural and Propane/LP Gas: Natural and pro pane/LP gas are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
Do not use this fireplace to cook food or burn paper or other flam mable material.
This fireplace reaches high tem peratures. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surface to cool before touching.
Carefully supervise young chil dren when they are in the room with fireplace.
Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor or liquids. Do not run fireplace where these are used or stored.


Switch Bracket for Optional Remote and Blower
Figure 1 - Direct-Vent Fireplace with
Local Codes Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada). *Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
Upper Louver Panel · Flue Collar · Millivolt Ignition

Preparation
Flush with a wall
Through exterior wall enclosed in a chase
Figure 2 - Common Fireplace Locations
36 1/4"
23 1/4"
FW
Figure 3 - Fireplace Bottom Dimensions
Corner installation · 48"

Clearances Minimum clearances to combustibles for the fireplace are as follows: *Back and sides 0"/mm Perpendicular walls 6" (152 mm) Floor 0"/mm Ceiling to louver opening 42" (1067 mm) Front 36" (914 mm) Top of Standoffs 0"/mm Vent (See venting instructions for specific venting clearances.) Combustible material with a maximum thick ness of 5/8" may be flush with the top front of fireplace. * For back and sides of fireplace, do not pack with insulation or other materials. 0" clearance to com bustible materials are for framing purpose only.
NOTICE: This fireplace is in tended for use as supplemental heat. Use this fireplace along with your primary heating sys tem. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

Preparation
framing and finishing Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met. For available accessories for this fireplace, see Accessories on page 42. If you are using a sepa rate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombustible mantels at any height above the fireplace. Note: Noncombustible mantels may discolor!
C B
D E
F G
40 1/8"
48 1/4" 23" Horizontal Vent 26 1/2" Vertical Vent
Figure 4 - Framing Clearances for Installation Against an Exterior Wall
Figure 6 - Clearances for Combustible
215/8"
131/2"
58 1/2"
415/8"
Figure 5 - Framing Clearances for Corner


TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.5 cm) minimum] B = clearance to window or door that may be opened [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] C = clearance to permanently closed window [minimum 12" (30.5 cm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24" (61 cm) from the center-line of the terminal [18" (45.7 cm) minimum] E = clearance to unventilated soffit [12" (30.5 cm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within 36" (91.4 cm) horizontally from the center line of the regulator
I = clearance to service regulator vent outlet [*72" (182.9 cm) minimum] J = clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] K = clearance to a mechanical air supply inlet [*In Canada, 6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within 10 ft. (3 m) horizontally] L = † clearance above paved side-walk or a paved driveway located on public property [*84" (213.3 cm) minimum] M = clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡] N = clearance above a roof shall extend a minimum of 24" (61 cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18" (45.7 cm) † vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Outside Corner Recessed Location

C = Maximum depth of 48" (121.9 cm) for recessed location D = Minimum width for back wall of recessed location - Combustible - 38" (965 mm) Noncombustible - 24" (61 cm) E = Clearance from corner in recessed location- Combustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm)
Combustible & Noncombustible H = 24" (61 cm) J = 20" (50.8 cm)
Figure 7 - Minimum Clearances for Termination Cap
Inside Corner


5. Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10 3/4" x 10 3/4" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9).
instructions
Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Hori zontal installations using round termination require exterior portion of wall firestop (see Figure 14, page 12). 1. Set the fireplace in its desired location and deter mine the route your horizontal venting will take. Do not secure the fireplace until all venting has been installed. Some installations require sliding the fireplace in and out of position to make final venting connections. Figures 14 through 18 on pages 12 through 14 show different configura tions for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired vent ing route. If they are, you may want to adjust the location of the fireplace. 2. Direct vent pipe sections and components are designed with special twist-lock connections. Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sec tions together and twist one section clockwise approximately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. 3. Use a 45° elbow to connect venting system to fireplace flue collar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc. 4. Assemble the desired combination of pipe and elbows to the fireplace flue collar. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassem blies for convenience.
Figure 8 - Vent Pipe Connections
Vent Opening Combustible Wall
10 3/4" Inside Framing (27.3 cm)
10 3/4" (27.3 cm)
10 3/4" (27.3 cm)
Vent Opening Noncombustible Wall
8 1/2" (21.6 cm)
Figure 9 - Vent Opening Requirements


6. Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exterior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal between it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings. Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the standoff. Ap ply non-hardening mastic around outside edge of standoff. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material. 7. Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12). 8. Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4" (see Figure 13, page 12). 9. Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13, page 12, for horizontal termination details. 10. Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.
Figure 10 - Installing Horizontal Vent Cap

Apply Mastic to All Four Sides
Figure 11 - Installing Siding Standoff

Vent Cap (Horizontal Termination)
Horizontal Vent Pipe Figure 12 - Connecting Vent Cap with

Minimum Pipe Overlap 11/4"
Adjustable Pipe 12" Max.
Horizontal High Wind Square Termination
Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall
Square Termination Vertical (V) Horizontal (H) 32 3/4" min. 17" max.
Apply Mastic to Outside Edge of Standoff
10 3/4" x 10 3/4" Framed Opening
Exterior Portion of Wall Firestop (Round Termination Only)
Exterior Wall with Vinyl Siding
Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed
Horizontal Termination Configurations Figures 14 through 18 show different configura tions and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: If using a venting configuration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required.
* If installing this fireplace at altitudes of 4000 feet and above, it is recommended that an additional vertical height of 6" be added to the vent system.
Figure 14 - Horizontal Termination Configuration for Square or Round



As Required for (V), See Chart for Pipe Section Required
Required Vertical (V) Vertical Pipe Horizontal (H) *43 1/2" min. None 30" max. 54 1/2" min. 1 ft. 48" max. 66 1/2" min. 2 ft. 60" max. 78 1/2" min. 3 ft. 84" max. 90 1/2" min. 4 ft. 20' max. * Ground Floor Corner Venting
Figure 15 - Horizontal Termination Configuration for Corner Installation Using One

Figure 16 - Snorkel Termination Configurations for Below Ground Installation
90° Elbow · 90° Elbow · Snorkel Termination

HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.

Horizontal (H2) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max. 20' max. 8' max. 20' max.
Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

Horizontal (H2) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max.
Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows
with Termination at 90° with Fireplace

Flat Ceiling Installation 1. Cut a 10 3/4" square hole in the ceiling us ing the locating hole as a center point. The opening should be framed to 10 3/4" x 10 3/4" (273 mm x 273 mm) inside dimensions, as shown in Figure 9 on page 10 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceil ing or and attic space, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. If the area above the ceiling is a living space, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 20). 2. Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. Be sure all pipe and elbow connections are fully twist-locked (see Figure 8, page 10). 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 10 3/4" x 10 3/4" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combustible materials. Frame the opening as shown in Figure 9, page 10. 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstruc tions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Fig ure 19). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.
installation for vertical termination Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct the venting system, consider an offset (see Figure 19) to avoid cut ting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. 2. Set the fireplace in desired location. Drop a plumb line down from the ceiling to the posi tion of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.
If area above is an attic space or insulated
area, install firestop above framed hole.
If area above is a living space, install
firestop below framed hole.
Figure 19 - Offset with Wall Strap and 45°
Figure 20 - Installing Firestop

Venting with Two 90° Elbows
Horizontal (H1) +
Horizontal (H2) 5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max. 20' max. 8' max.
5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roof ing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 19, page 15. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 8. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem. 7. Twist-lock the vent cap onto the last section of vent pipe. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation.
as shown.
Figure 21 - Vertical Venting Configuration Using Two 90° Elbows
with Two Horizontal Runs (Vertical Round High Wind Termination Shown)

Venting with One 90° Elbow Vertical (V) Horizontal (H) 5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max. 20' max. 8' max.
Vertical Termination Configurations Figures 21 through 24 show four different con figurations for vertical termination.
Figure 22 - Vertical Venting Configuration Using One 90° Elbow (Vertical Round High Wind Termination



5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: Vertical (V1) + Vertical (V2) = 40' max.
Figure 24 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
Figure 23 - Vertical Venting Configuration
Using Two 90° Elbows (Vertical Round
High Wind Termination Shown)
High Altitude Installation Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada). Fireplaces for High Altitude (models ending in -HA) are for installation above 4000 feet only. These fireplaces are equipped with parts specific for higher altitudes. IMPORTANT: These fireplac es can NOT be converted to Propane/LP gas. When installing a non-high altitude fireplace at an elevation above 2000 feet (in the USA), you may
need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities. IMPORTANT: For horizontal installations above 2,000 feet, it is recommended that a 12" extension pipe be added before starter elbow (see Figure 25, page 18) and a round horizontal termination be used.

Number Description VKR-58 Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Flue Restrictor, Vertical High Wind Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm Collar, Roof Flashing [0/12 - 6/12], 26 Screws) VKC-58 Corner Vent Kit, Galvanized (Includes 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Termination, 6" Pipe, 90° Elbow, 18 Screws) HHTK-58 High Wind Round Horizontal Termination Kit (Includes Round Termination, Wall Firestop, 45° Elbow) HHT-58 High WInd Round Horizontal Termination Kit, Galvanized HTS-58 Horizontal Square Termination, Galvanized HTKS-58 Horizontal Square Termination Kit (Includes: Square Termination, Wall Firestop, 45° Elbow) VT-58 Vertical Round Termination, Galvanized ST-58-14 14" Snorkel Termination, Galvanized ST-58-36 36" Snorkel Termination, Galvanized SC-58 Storm Collar, Galvanized WF-58 Wall Firestop, Galvanized RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galvanized VR-58 Vertical Restrictor, Galvanized S-58 Vinyl Siding Standoff, Galvanized WS-58 Wall Strap CS-58 Cathedral Ceiling Support FP-58 Firestop Plate SF-58 Stucco Flashing - For use with HTS-58 RF-58 Flat Roof Flashing
Figure 25 - Recommended 12" Extension
for High Altitude Installation
DESA (5"/8") Pipe & Vent Kits Number Description P58-6 6" Section Double Wall Pipe, Galvanized P58-12 12" Section Double Wall Pipe, Galvanized P58-24 24" Section Double Wall Pipe, Galvanized P58-36 36" Section Double Wall Pipe, Galvanized P58-48 48" Section Double Wall Pipe, Galvanized PA58-712 Adjustable 7"-12" Section Double Wall Pipe, Galvanized E58-45 45° Elbow, Galvanized E58-90 90° Elbow, Galvanized VKG-58 Ground Floor Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 16 Screws) VKB-58 Basement Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 4' Pipe, 90° Elbow, 20 Screws) VKS-58 Snorkel Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)
45° Starter Elbow · 12" Extension

5. Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 27). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro vided on shaft. 7. Turn on power to duplex outlet if previously turned off per the warning in column 1. 8. Plug in blower power cord. a. If your firebox is installed as a freestanding
CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 42).

unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox. b. If your firebox installation is recessed

and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.
Model BK Installation Follow all instructions provided in the blower accessory kit. 1. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade ter minals on the blower motor (see Figure 26). 2. Attach green ground wire from power cord to blower housing using screw provided (see Figure 26). Tighten screws securely. 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 26). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight.
Figure 26 - Blower Model BK
Speed Control Control Shaft

Duplex Outlet (Located underneath firebox floor against lower right outside wall)
Figure 27 - Attaching Speed Control to
Switch Bracket · Locknut Control Knob · Firebox

3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 29 in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 29). 4. Be certain that all wire terminals are securely at tached to terminals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight. 5. Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 27, page 19). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 27, page 19).
110/115 V.A.C.
Wiring Diagram Decal 12" in Front of Blower
Figure 28 - Location of Wiring Diagram Decal (Model May Vary From Illustration)
Model BKT Installation Note: When installing the BKT thermostati cally-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed. 1. Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower as sembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 29). 2. Connect wire harness and power cord ter minals. Connect the blue jumper wire to the blower motor terminal and the right side ter minal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal. Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.
Ring Terminal on Green Wire
Route BKT Blower Through This Area Magnets Blower Location Side View Firebox Bottom
Figure 29 - Blower Model BKT

7. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly. 8. Turn on power to duplex outlet if previ ously turned off per the warning in column 1, page 19. 9. Plug in blower power cord to duplex outlet. 10. The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically. 11. Peel off the backing paper and stick the sup plied wiring diagram decal on the firebox bot tom approximately 12" in front of the blower (see Figure 28, page 20).
Variable Fan Switch Fan Switch
110/115 V.A.C.
Figure 30 - Blower Wiring Diagram for

We recommend that you install a sediment trap/ drip leg in supply line as shown in Figure 32. Lo cate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sedi ment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is in stalled wrong, fireplace may not run properly.
CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*
Natural - From Gas
Meter (5.5" W.C. to 10.5" W.C. Pressure) Propane/LP From
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 32). IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
Approved Flexible Gas Line
External Regulator (11" W.C. to
14" W.C. Pressure)
Cap Pipe Tee Joint Nipple
Figure 32 - Gas Connection
* The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer.
Propane/LP Supply Tank External Regulator with Vent Pointing Down
Figure 31 - External Regulator with Vent
Pointing Down (Propane/LP Only)
3" Minimum · Sediment Trap/Drip Leg

To Gas Supply (Natural)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 34). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 35 or 36). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
Figure 33 - Connecting Flexible Gas Line


Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equip ment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air.


Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 34, page 23). 2. Open propane/LP supply tank valve or main gas valve located on or near gas meter for natural gas. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 35 or 36, page 23). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, page 27). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 28).
Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the right. 2. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver. 3. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 38). 4. Attach the terminal wires to the battery. 5. Connect wires from receiver to TH and TPTH to control valve (see Figure 39). 6. Replace the switch bracket.

Installing optional wall Mount Switch - gwmS2 1. Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 37. If wires are not con nected as shown the switch will not work. 2. Route the 25 ft. wire through openings pro vided on the sides of the burner system to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall.
Figure 38 - Attaching Alkaline Battery to

To Optional Remote Accessory
To Wall Switch Accessory

Figure 39 - Control Valve Terminals
Figure 37 - Connecting Wall Switch to
9-Volt Alkaline Battery · Receiver · Control Valve

Removing Louver Panels Remove the top and bottom louver panels by si multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 41). Repeat for bottom spring latches and pull the lou vers outward. To install or replace items removed, simply reverse the procedures above.
Installing 9-Volt Alkaline Battery in Hand- Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote control unit.
Figure 41 - Removing Louver Panel
Removing Glass Door If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame. 1. Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the fire box. Set assembly aside. 2. Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 42). 3. While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 42).
Figure 40 - Installing Battery in Hand-
Held Remote Control Unit



Cleaning Glass Door See Cleaning and Maintenance on page 31.
Installing lava rock and glowing embers It is very important to keep logs exactly as installed. Do not modify logs. Only use log set designed for this fireplace. Logs under log/grate assembly are attached to burner. Do not attempt to move these logs as this will damage logs.
Figure 43 - Placing Ember Material on

You may purchase brick liner from your local retailer or see Accessories, page 42.
Open louvers, remove screen, unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 25. 1. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed front section of the burner (see Figure 43). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided. 2. Pour lava rock onto plenum but not onto flat burner. It is not necessary to use all of the lava rock provided.

1. Remove top and bottom louvers to allow ac cess to door latches. 2. Unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 25. 3. Carefully remove lava rock and ember mate rial. Remove log/grate assembly by unscrew ing grate from plenum. The two logs under the grate are attached to burner. DO NOT attempt to remove. 4. Remove screws that attach plenum to burner to remove plenum. 5. Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

Embers · Burner

Operating Fireplace

6. Install rear brick panel first. Rest bottom edge of panel on back edge of burner assembly (see Figure 44). 7. Install left side brick panel by sliding it be tween the burner assembly and the side of the firebox (see Figure 44). 8. Install the right brick panel using the same method described in step 6 for left brick panel. 9. Replace deflector shield using screws removed in step 4. 10. Using screws removed in step 4, replace plenum and attach to burner. 11. Using screws removed in step 3, replace log/grate assembly. Be careful when replac ing log/grate assembly not to chip logs on burner. 12. Install lava rock and glowing embers. See Installing Lava Rock and Glowing Embers, page 26. 13. Close glass door and lock latches on top and bottom of door and replace screen. See Remov ing Glass Door, steps 5 and 6 on page 25. 14. Close top and bottom louvers.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has

been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
lighting instructions 1. STOP! Read the safety information above. 2. Open lower louver panel. 3. Turn off all electric power to the fireplace. 4. Push in gas control knob slightly and turn clockwise to OFF. 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don't smell gas, go to the next step. 6. The pilot is located by the main burner and should not require accessing for lighting.
Figure 44 - Installing Rear Brick Panel

PROCEDURE 1. Remove glass door (see Removing/Replacing Glass Door, page 25). 2. Follow steps 1 through 8 under Lighting Instructions, page 27. 3. Depress gas control knob and light pilot with match. 4. Keep gas control knob pressed in for 30 sec onds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 9 through 12 under Lighting Instructions. 5. Replace glass door (see Removing/Replacing Glass Door, page 25).
REMOTE OPERATION Note: All remote control accessories must be purchased separately (see Accessories, page 42). Follow instructions included with the remote control.
After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere be tween HI and LO. Slide the selector switch to the REMOTE position (see Figure 46). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
H
F
F
O
T
O
O
N
O
Figure 45 - Control Valve
TO APPLIANCE 1. Open lower louver panel. 2. Set selector switch in the OFF position to prevent draining battery. 3. Turn off all electrical power to the appliance if service is to be performed. 4. Push in gas control knob slightly and turn clockwise to OFF. 5. Close lower louver panel.
Blower Control Knob (Optional Accessory) Variable Control Knob
O
N
REMOTE
O
T
O
O
H
OFF
P
F
F
ON
Gas Control Knob in ON Position
Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn gas control knob clockwise to the PILOT position. 2. Set selector switch in the OFF position.
Selector Switch in Remote Position
Figure 46 - Setting the Selector Switch, Gas Control Knob and Variable Control
Knob for Remote Operation
Gas Control Knob · Variable Control Knob · Piezo Ignitor

3. Set the desired room temperature by press ing the TEMP + or - buttons. 4. Press the POWER and LOCK buttons together to turn off the fireplace Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.
On/Off Series Model HRC100 Hold the control button on the hand-held remote until burner turns on. Hold the con trol button again until burner turns off (see Figure 47).
To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.
To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.
Digital Display Shows Temperature and Settings
Locks System to Prevent Accidental Ignition
Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting
ROOM TEMP
SET TEMP
TEMP POWER
LOCK
Turns Burners On or Off
Increases or Decreases Room Temperature in AUTO Mode
Figure 47 - On/Off Hand-Held Remote
Figure 48 - Thermostat Hand-Held
Thermostat Series Model HRC200 The hand-held remote can be operated using either the manual mode (MANU) or thermo static mode (AUTO) (see Figure 48). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.
Remote Control Unit HRC200
Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.
Manual Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press the MANU button to turn on the fireplace. 3. Press the POWER and LOCK buttons together to turn off the fireplace.
Auto Shutoff Feature 1. If the average room temperature exceeds 82° F (28° C), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode. 2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.
Auto (Thermostatic) Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press AUTO button to select this mode.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow er will continue to run. The blower will shut off after the firebox temperature decreases. The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.
Key Pad Lock Feature This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.
Thermostat
Inspecting Burners Check pilot flame pattern and burner flame pat terns often.
Light the fireplace as instructed in Lighting Instructions on page 27. Set wall thermostat to desired temperature. This thermostat has been electronically cali brated at the factory and requires no adjust ment or leveling. Upon installation, the thermostat must be al lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit. IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.
blower accessory Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermo statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.
Figure 48 - Pilot Assembly


Glass must be cleaned periodically. During start- up it is normal for condensation to form on the inside of the glass causing lint, dust and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door, page 25 of this manual when removing glass door for cleaning.

Figure 50 - Typical Flame Pattern
Maintenance
If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 25). Vacuum all glass pieces with a shop vac.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 37 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 25 for instructions for replacing glass door.
venting system Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are ex posed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a quali fied service person. 2. Remove the vent cap and shine a flashlight into the vent. Remove any foreign material. 3. Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather. 4. Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at pilot
When ignitor button is pressed, there is spark at pilot but no ignition

POSSIBLE CAUSE
REMEDY
Pilot lights but flame goes out when control knob is released
Burner does not light after pilot is lit
Burner backfiring during com bustion
Slight smoke or odor during initial operation
Delayed ignition burner

POSSIBLE CAUSE
REMEDY
Heater produces a whistling noise when burner is lit
Fireplace produces a clicking/ ticking noise just after burners are lit or shut off
Remote does not function
Fireplace shuts off in use
Glass soots

POSSIBLE CAUSE
REMEDY
Fireplace produces unwanted odors
Gas odor even when control knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace

Replacement Parts Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Technical Service You may have further questions about installation, operation or troubleshooting. If so, contact DESA’s Customer Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA’s technical service web site at www.desatech.com.



Models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Series This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.
KEY NO.
PART NUMBER DESCRIPTION QTY. 1 ** Firebox Assembly 1 2 ** Face Weldment 1 3 108328-01 Door Assembly 1 108328-02 Door Assembly (V Models Only) 1 4 108331-01 Top Louver Assembly 1 5 108331-02 Bottom Louver Assembly 1 6 ** Fireplace Top 1 7 ** Fireplace Top Insulation 1 8 ** Fireplace Surround 1 9 109082-01 Heat Shield 1 10 116216-01 Log Set with Grate Assembly 1 11 116338-01 Right Burner Log 1 12 116339-01 Left Burner Log 1 13 See Below Left Refractory Brick Panel 1 14 See Below Rear Refractory Brick Panel 1 15 See Below Right Refractory Brick Panel 1 16 108455-01 Screen Rod 1 17 107840-01 Screen 2 18 11418 Push-On Nut 2 19 14123 Strain Relief 1 20 21171 Gas Knock-Out Cover 2 21 24353 Handy Box Assembly 1 22 24460 Gas Conduit Assembly 1 23 116211-01 Burner Assembly (Natural Gas) (See page 40) 1 116211-02 Burner Assembly (Propane/LP Gas) (See page 40) 1 116211-05 Burner Assembly for High Altitude Models (See page 40) 1 24 116375-01 Plenum 1 PARTS AVAILABLE - NOT SHOWN 25487 Lava Rock/Bag Assy 1 27253 Notice Label 1 55240 Vent Label 1 116388-01 Grate Finial 2 ** Not a field replaceable part.
CGCDV42NR CGCDV42PR
VVC42NB VVC42PB VVC42NB-HA
VVC42NH VVC42PH DESCRIPTION QTY 111299-02 111299-01 111302-02 111302-01 Left Refractory Brick Panel 1 111297-02 111297-01 111300-02 111300-01 Rear Refractory Brick Panel 1 111298-02 111298-01 111301-02 111301-01 Right Refractory Brick Panel 1
VC42NH VC42PH



Burner assembly for models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Series This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.
KEY NO.
PART NUMBER DESCRIPTION QTY. 1 ** Burner Pan Assembly 1 2 ** Base Grate 1 3 ** Firebox Base Bottom 1 4 ** Valve Bracket 1 5 11107 Screw, #10-32 x 1/4 Zinc 4 6 ** Firebox Bottom 1 7 11102 Screw, #8-32 x 3/8 Zinc 2 8 116344-01 Tubing Assembly 1 9 111288-02 Flex Gas Line 1 10 108084-02 Pilot Assembly (Natural Gas) 1 108084-03 Pilot Assembly (Propane/LP Gas) 1 108084-05 Pilot Assembly (-HA Models) 1 11 14389 Natural Gas Valve 1 14390 Propane/LP Gas Valve 1 117370-01 Natural Gas High Altitude Valve 1 12 11165 Screw, #10 x 5/8 Zinc 23 13 111913-01 Burner Base Gasket 1 14 14396 Brass Fitting 2 15 116345-01 Pilot Bracket 1 16 26827 Switch Bracket 1 17 11226 Flat Washer 7/8" ID x 2" OD 2 18 11214 Bulkhead Fitting with Washer 2 19 14296 Elbow 3/8" 1 20 24874 Burner Orifice #32 (Natural Gas) 1 23098 Burner Orifice #50 (Propane/LP Gas) 1 21 14492 Piezo Ignitor 1 22 14511 Piezo Bracket 1 PARTS AVAILABLE - NOT SHOWN 108085-03 Pilot Injector #62 (-HA Models Only) 1 **Not a field replaceable part.

Rolled Louver trim kit (Rolled Louvers Only) (Not Shown) LT42B - Brushed Brass LT42P - Platinum LT42PB - Polished Brass
Purchase these fireplace accessories from your local retailer. If they can not supply these ac cessories, call DESA’s Sales Department at 1-866-672-6040. for information. You can also write to the address listed on the back page of this manual.
Perimeter Trim kit (Not Shown) PT42 - Black PT42B - Brushed Brass PT42P - Platinum PT42PB - Polished Brass
Brick Liner Kit (Not Shown) BL42DA - Textured Refractory BL42DSA - Standard Refractory BL42DHA - Textured Refractory Herringbone BL42DHSA - Standard Refractory Herringbone This brick liner adds a touch of style to your direct- vent fireplace. Complete installation instructions included in this manual.

Flexible gas Line connector CIK (Not Shown) For all models.
Manual blower Kit - BK Manual variable control blower accessory provides better heat distribution. Complete installation and operation instructions included in this manual.
Propane/natural gas conversion kit (Not Shown) IMPORTANT: NOT to be used for High Altitude (-HA) Models. PCDM-42VC - Propane/LP Gas Conversion Kit NCDM-42VC - Natural Gas Conversion Kit

Face/Louver Panel Kit (Not Shown) FPD42 - Filigree, Black FPD42B - Filigree, Brushed Brass FPD42P - Filigree, Platinum FPD42PB - Filigree, Polished Brass
Thermostatically- controlled blower kit - BKT Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instructions included in this manual.

Receiver and Hand-Held on/off Remote Control Kit HRC100 Series Allows the fireplace to be turned on and off conveniently. A wall-mounted docking station is included.
Receiver and Hand-Held Thermostat Remote Control Kit - HRC200 Series Allows the fireplace to be operated in a manually or thermostatically-controlled mode. You can adjust your heat settings and turn the fireplace on or off without leaving the comfort of your easy chair. A wall-mounted docking station is included.
Wall mounted thermostat control kit - gwmt1 (Not Shown) Allows easy wall access for thermostatic operation of your fireplace.
Wall mounted on/off switch gwmS2 (Not Shown) Allows burner system to be turned on and off with a wall switch.

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUEN TIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com