DIRECT-VENT FIREPLACEp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1BHDV37NC, BHDV37PC, BHDV41NC, AND BHDV41PCp.1FOR YOUR SAFETYp.1SAFETY INFORMATIONp.2WARNINGSp.2PRODUCT IDENTIFICATIONp.3GLOSSARY OF TERMSp.3LOCAL CODES PRODUCT FEATURES OPERATIONp.3PIEZO IGNITORp.3PRE-INSTALLATION PREPARATIONp.4CLEARANCESp.4LOCATION AND SPACE REQUIREMENTSp.4FRAMING AND FINISHINGp.4RWp.4FWp.4PRE-INSTALLATION PREPARATION Continuedp.5GENERAL VENTINGp.5VENTING INSTALLATIONp.7INSTALLATION PLANNINGp.7INSTALLATION PRECAUTIONSp.7Installing Vent System in a Chasep.7VENTING INSTALLATION Continuedp.8UPp.9Horizontal Termination Configurationsp.10INSTALLATION FOR VERTICAL TERMINATIONp.12Vertical Termination Configurationsp.13Vanguard Rigid Venting (Cont.)p.15HIGH ALTITUDE INSTALLATIONp.15SIMPSON DURA-VENT GS 4" x 6 5 / 8 "p.15CHECK GAS TYPEp.16Installing GA3700/DA3610TA Blowersp.16FIREPLACE INSTALLATIONp.16INSTALLING OPTIONAL BLOWER ACCESSORYp.16Attaching Thermal Switch to DA3610TA ThermostaticallyControlled Blowerp.16FIREPLACE INSTALLATION Continuedp.18INSTALLING GAS PIPING TO FIREPLACE LOCATIONp.18Installation Items Neededp.18CHECKING GAS CONNECTIONSp.19CONNECTING FIREPLACE TO GAS SUPPLYp.19Pressure Testing Gas Supply Piping Systemp.19INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1p.21INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2p.21REMOVING/REPLACING GLASS DOORp.22INSTALLING OPTIONAL BRICK LINER D8037A/D8041p.23INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSp.24OPERATING FIREPLACEp.25READ BEFOREp.25Shutting Off Burners Only (pilot stays lit)p.25LIGHTINGp.25MANUAL LIGHTINGp.25OPTIONAL REMOTEp.25Thermostat Control Operationp.25TO TURN OFF GASp.25TO APPLIANCEp.25OPERATING FIREPLACE Continuedp.26OPERATING OPTIONAL BLOWERp.26ACCESSORYp.26ON OFFp.26REMOTEp.26ONp.26OFFp.26INSPECTING BURNERSp.27BURNER FLAME PATTERNp.27OPERATING OPTIONAL GWMT1p.27PILOT ASSEMBLYp.27WALL MOUNTEDp.27THERMOSTATp.27OPERATING OPTIONAL GWMS2p.27CLEANING AND MAINTENANCEp.28VENTING SYSTEMp.28GLASS DOORp.28TROUBLESHOOTINGp.29OBSERVED PROBLEMp.29POSSIBLE CAUSEp.29REMEDYp.29TROUBLESHOOTING Continuedp.30REPLACEMENT PARTSp.32WIRING DIAGRAMp.32(N.O.)p.32
Page 1 of the Desa BHDV41PC user manual — FOR YOUR SAFETY
Page 1 · click to enlarge
Page 1

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

BHDV37NC, BHDV37PC, BHDV41NC, AND BHDV41PC

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

FOR YOUR SAFETY

— Installation and service must be performed by a qualified in- staller, service agency, or the gas supplier.

  • WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electrical switch
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

— This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

Save this manual for future reference.

®

Page 2 of the Desa BHDV41PC user manual — WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace
  • in high traffic areas
  • in windy or drafty areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shut-down. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. 7. Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. 8. Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, pet hair, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10. Have venting system inspected annu- ally by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Mainte- nance, page 28. 11. Keep the area around your fireplace clear of combustible materials, gaso- line, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire- place nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANS/NFPA 70, or the Cana- dian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combus- tion and ventilation air in any way. Pro- vide adequate clearances around air openings into the combustion chamber along with adequate accessibility clear- ance for servicing and proper operation. 16. Do not install fireplace directly on car- peting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel ex- tending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to ar- range for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this fireplace. 20. Do not operate fireplace with glass door removed, cracked, or broken.

WARNINGS

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and ser- viced by a qualified service person. Some people are more affected by carbon monox- ide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

® · 2 106517

Page 3 of the Desa BHDV41PC user manual — PIEZO IGNITOR
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

GLOSSARY OF TERMS

Chase - A box-like enclosure to protect venting from the elements when the venting run is on the outside of a structure.

Mastic - A pliable sealent for use around the vent terminal.

Snorkel Termination - A box that raises the horizontal termination above ground level clearances.

Blower Adjustment (Optional Installation)

Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather.

Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding.

Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling.

Figure 1 - Vanguard Direct-Vent Fireplace BHDV Series

LOCAL CODES PRODUCT FEATURES OPERATION

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1, also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada).

This direct-vent fireplace is clean burning and vents easily through outside walls or vertically using outside air for combustion. Heat is generated by both realistic flames and glowing embers. When used without the blower accessory, the fireplace requires no electricity making it ideal for emergency backup heat.

*Available from:

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

PIEZO IGNITOR

Batterymarch Park Quincy, MA 02269

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

Show 15 more labels / short text on this page
Top Louver Panel · Vent Opening · Nailing Flange · Stand-off · Glass Door Assembly · Log Set · Pilot Assembly · Burner · Piezo Ignitor · Valve · Grate Assembly · Glowing Embers · Lower Louver Panel · Lava Rock · 3 106517
Page 4 of the Desa BHDV41PC user manual — FW
Page 4 · click to enlarge
Page 4

PRE-INSTALLATION PREPARATION

CLEARANCES

Desa BHDV41PC — CLEARANCES diagram (page 4)
Fig. 1

Minimum clearances to combustibles for the fireplace are as follows:

LOCATION AND SPACE REQUIREMENTS

Back, and sides 0"/mm Perpendicular walls 6" (152mm) Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) Top of Standoffs 0"/mm

Determine the safest and most efficient loca- tion for your Vanguard direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact loca- tion for your fireplace.

See General Venting on page 5 for specific venting clearances.

FRAMING AND FINISHING

Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clear- ances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fire- place must set on a metal or wood panel extending the full width and depth of the fireplace.

When deciding the location of your fire- place, follow these rules: 1. Do not connect this fireplace to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance. 2. Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies. 3. Proper clearances must be maintained. 4. If your fireplace is to be installed di- rectly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Figure 5 - Framing Clearances for Typical Fireplace Installation

See Accessories on pages 38 and 39 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper installation height. You can install noncom- bustible mantels at any height above the fireplace.

Desa BHDV41PC — FRAMING AND FINISHING diagram (page 4)
Fig. 2
Desa BHDV41PC — FRAMING AND FINISHING diagram (page 4)
Fig. 3

34 3/4" 36 3/4"

Figure 2 - Common Fireplace Locations

RW

37 1/2" 41 1/2"

D

20" Vertical Termination 19" Horizontal Termination

FW

Fireplace sizeD x FW x RW 37"18 1/2"37"14" 41"18 1/2"41"18"

37" Fireplace and the bottom number is exclusive to the 41" Fireplace

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

Figure 3 - Fireplace Bottom Dimensions

® · 4 106517

Page 5 of the Desa BHDV41PC user manual — A
Page 5 · click to enlarge
Page 5

PRE-INSTALLATION PREPARATION Continued

GENERAL VENTING

These models are approved for use with Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations as well as both flex and rigid Vanguard vent components.

  • Your fireplace is approved to be vented either through the side wall, or vertically using the following guidelines:
  • Only use Vanguard or Simpson DuraVent GS venting components or kits specifically approved for this fireplace.
  • Minimum clearance between vent pipes and combustible materials is 1" (25 mm), except where stated otherwise.
  • Combustible material may be flush with the top front of fireplace with a maximum thichness of 3/4".
  • Do not recess venting terminals into a wall or siding.
  • You must install a vinyl siding standoff if vinyl siding is covering the exterior wall.
  • Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.
  • You may paint the vent terminal with 450ºF (232ºC) heat-resistant paint to coordinate with the exterior finish.
  • There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.
  • Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

9 1/4" 41"

10 1/4" 8 3/4" 37" 41" 37 1/2" 41 1/2"

is exclusive to the 37" Fireplace and the bottom number is exclusive to the 41" Fireplace

Figure 6 - Framing Clearances for Corner Installation

A

B

D

E

F

G

LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 8, page 6. You will avoid extra framing by positioning your fireplace against an already existing framing mem- ber. The sides of the fireplace may be posi- tioned directly against combustible walls.

Top of Louver Opening

Ref.Mantel DepthRef.Mantel from Top of Louver Opening 114" (356mm)A16" (406mm) 212" (305mm)B14" (356mm) 310" (254mm)C12" (305mm) 48" (203mm)D10" (254mm) 56" (152mm)E8" (203mm) 64" (101mm)F6" (152mm) 72" (51mm)G4" (101mm)

*Check with local codes or with the current CAN/CGA B149[.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54.

Figure 7 - Clearances for Combustible Mantels

Show 7 more labels / short text on this page
13" · 29" · Nailing Tabs · 58" · Wall · Continued · 5 106517
Page 6 of the Desa BHDV41PC user manual — G
Page 6 · click to enlarge
Page 6
Desa BHDV41PC — PRE-INSTALLATION PREPARATION Continued diagram (page 6)
Fig. 4 · PRE-INSTALLATION PREPARATION Continued

TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony

I = clearance to service regulator vent outlet [*72 inches (1829mm)

[*12 inches (305mm) minimum] B = clearance to window or door that may be opened

minimum] J = clearance to non-mechanical air supply inlet to building or the

[12 inches (305mm) minimum] C = clearance to permanently closed window [minimum 12 inches

combustion air inlet to any other fireplace [*12 inches (305mm) minimum] K = clearance to a mechanical air supply inlet [*72 inches (1829mm)

(305mm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal

minimum] L = † clearance above paved side-walk or a paved driveway located on

within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum] E = clearance to unventilated soffit [12 inches (305mm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within

public property [*84 inches (2133mm) minimum] M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡] N = clearance above a roof shall extend a minimum of 24 inches (610mm)

above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)

36 inches (914mm) horizontally from the center-line of the regulator

† vent shall not terminate directly above a side-walk or paved driveway which is located between two

single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1 Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Outside Corner Recessed Location

Desa BHDV41PC — PRE-INSTALLATION PREPARATION Continued diagram (page 6)
Fig. 5 · PRE-INSTALLATION PREPARATION Continued
Desa BHDV41PC — PRE-INSTALLATION PREPARATION Continued diagram (page 6)
Fig. 6 · PRE-INSTALLATION PREPARATION Continued

Balcony with No Side Wall

Balcony with Perpendicular Side Wall

Desa BHDV41PC — PRE-INSTALLATION PREPARATION Continued diagram (page 6)
Fig. 7 · PRE-INSTALLATION PREPARATION Continued

recessed location D = Minimum width for back wall of

G

recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in

Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm)

recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)

G = Combustible 24" (610mm)

Figure 8 - Minimum Clearances for Vent Terminations

Show 4 more labels / short text on this page
® · Inside Corner · Noncombustible 18" (457mm) · 6 106517
Page 7 of the Desa BHDV41PC user manual — Installing Vent System in a Chase
Page 7 · click to enlarge
Page 7

VENTING INSTALLATION

  • Installation of any component part not manufactured or approved by DESA International
  • Installation other than as instructed by these instructions

cal rise in an attic or second story, and allow for sufficient vent height above the roofline. You may use one or two 90° elbows in this vent configuration. See Vertical Termination Configurations on pages 13 and 14.

For two-story applications, firestops are re- quired at each floor level. If an offset is needed in the attic, additional pipe and el- bows will be required.

You may use a chase with a vent termination with exposed pipe on the exterior of the house. See Installing Vent System in a Chase, below.

WARNING: Seal all vent con- nections. Seal only the outer pipe connections with high temperature silicone (600°F/316° C). Before join- ing elbows and pipes, apply a bead of high temperature silicone seal- ant (GE RTV 106/Loctite RTV 81585) to the male end of the elbow or pipe. High temperature silicone must also be used to re-seal any connections after maintenance to venting system.

WARNING: Horizontal sec- tions of this vent system require a minimum clearance of 2" from the top of the pipe and 1" minimum to the sides and bottom. 1 1/2" clear- ance is required where the termi- nation penetrates a combustible wall. Vertical sections of this sys- tem require a minimum of 1" clear- ance to combustible materials on all sides of the pipe.

Your Vanguard direct-vent fireplace has been tested for a minimum 3' rise with a maximum 10" wall thickness. The maxi- mum horizontal run is 20' with 8' vertical rise (see Installation for Horizontal Termi- nation, page 8). The maximum vertical run is 30' (see Installation for Vertical Termina- tion, page 12).

It is very important that the venting system maintain its balance between the combus- tion air intake and the flue gas exhaust. Certain limitations apply to vent configura- tions and must be strictly followed.

INSTALLATION PLANNING

INSTALLATION PRECAUTIONS

  • There are two basic types of direct-vent installation:
  • Horizontal Termination
  • Vertical Termination

Installing Vent System in a Chase

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installa- tion. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.

A chase is a vertical box-like structure built to enclose venting that runs along the out- side of a building. A chase is not required for such venting.

It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.

  • Only a qualified service person should install venting system. The installer must follow these safety rules:
  • Wear gloves and safety glasses for protection
  • Use extreme caution when using ladders or when on roof tops
  • Be aware of electrical wiring locations in walls and ceilings

For Horizontal Termination: Select the amount of vertical rise desired. The horizon- tal run of venting must have 1/4" rise for every 12" of run towards the termination.

  • The following actions will void the warranty on your venting system:
  • Installation of any damaged venting component
  • Unauthorized modification of the venting system

You may use one or two 90° elbows in this vent configuration. See Horizontal Termina- tion Configurations on pages 10 and 11.

After framing the chase (see Framing and Finishing on page 4) install the vent system by following the installation instructions.

For Vertical Termination: Measure the dis- tance from the fireplace flue outlet to the ceiling. Add the ceiling thickness, the verti-

Continued · 7 106517

Page 8 of the Desa BHDV41PC user manual — VENTING INSTALLATION Continued
Page 8 · click to enlarge
Page 8

VENTING INSTALLATION Continued

INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.

Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 9 and 10). Snorkel kit SVK is also avail- able (see page 15). Follow the same in- stallation procedures used for standard horizontal terminations. If installing the snorkel termination below grade (base- ment applications), you must provide proper drainage to prevent water from entering the snorkel termination (see Figure 10). Do not back fill around the snorkel termination. 2. Rigid vent pipes and fittings have spe- cial twist-lock connections. Assemble the desired combination of pipe and el- bows to the appliance adaptor with pipe seams oriented towards the wall or floor. Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fit- tings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 11, page 9. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. Flexible vent pipe must be installed with spacer springs every 12". See Figure 11, page 9. All connections must be clamped tightly and sealed with high temperature silicone sealant as specified in the sec- ond warning statement on page 7.

Figure 9 - Snorkel Termination

Figure 10 - Snorkel Termination with Drainage Pipe

Show 18 more labels / short text on this page
® · Snorkel · 12" Minimum · · · · · Snorkel · 12" Minimum · Adequate drainage · · · · · · · · 8 106517
Page 9 of the Desa BHDV41PC user manual — UP
Page 9 · click to enlarge
Page 9

VENTING INSTALLATION Continued

4. Apply a bead of non-hardening mastic around the outside edge of the vent cap. Position the vent cap in the center of the 7 1/2" or 10" hole on the exterior wall with the arrow on the vent cap pointing up. Insure proper clearance of 1" to combustibles is maintained. At- tach the vent cap with four wood screws supplied (see Figure 13). Note: Re- place the wood screws with appropri- ate fasteners for stucco, brick, concrete, or other types of siding.

6. Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1 1/4". Apply silicone to the outer pipe connection. Fasten all vent connections with screws provided. Refer to Fireplace Installation on page 16 for instructions on securing unit to framing or floor. 7. Slide the wall thimble against the inte- rior wall surface and attach with screws provided (see Figure 15).

3. Attach vent pipe assembly to the fire- place. Set fireplace in front of it’s per- manent location to insure minimum clearances. Mark the wall for a 10" square hole (for noncombustible ma- terial such as masonry block or con- crete, a 7 1/2" diameter hole is accept- able). See Figure 12. The center of the hole should line up with the center- line of the horizontal rigid vent pipe. Cut a 10"x10" (254mm x 254mm) square hole through combustible ex- terior wall (7 1/2" [190mm] diameter hole if noncombustible). Frame as nec- essary (see Figure 12).

For vinyl siding use vinyl siding stand- offs between vent cap and exterior wall. The vinyl siding standoff prevents ex- cessive heat from melting the vinyl sid- ing material. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff in- stead of the vent cap assembly. Use wood screws provided to attach the standoff. See Figure 14. 5. Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap (see Figure 15).

Cut Vinyl Siding Away to Fit Standoff

UP

Apply Mastic to All Four Sides

Figure 14 - Installing Vinyl Siding Standoff

Rigid Vent Pipe Flexible Vent Pipe

Apply Mastic to All Four Sides

Figure 11 - Vent Pipe Connections

Vent Opening Combustible Wall

UP

Figure 13 - Installing Horizontal Vent Cap

Vent Cap (Horizontal Termination)

Vent Opening Noncombustible Wall

Horizontal Vent Pipe Figure 15 - Connecting Vent Cap with Horizontal Vent Pipe

7 1/2" (190mm)

Figure 12 - Vent Opening Requirements

Show 23 more labels / short text on this page
4" Clamp · Wood Screw · Female Locking Lugs · 7" Clamp · Standoff · Spacer Spring · 4" Flex Pipe · Nut · Male Slots · Bolt · 7" Flex Pipe · Vent Cap · Interior Wall Surface · Wall Thimble · 10" (254mm) · Wood Screw · 10" (254mm) · Vent Cap · (Framing · Detail) · Screw · Continued · 9 106517
Page 10 of the Desa BHDV41PC user manual — UP
Page 10 · click to enlarge
Page 10

VENTING INSTALLATION Continued

UP

Horizontal Termination Configurations

Vertical (V) Horizontal (H)

44" min. 29" max. (30° and 90° only, no vertical pipe)

Figures 16 through 20 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.

55" min. 41" max. (30° elbow, 1' vertical pipe, 90° elbow)

67" min. 60" max. 79" min. 84" max. 96" min. 20' max.

BVK Vent Kit Shown

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

Desa BHDV41PC — UP diagram (page 10)
Fig. 8
Desa BHDV41PC — UP diagram (page 10)
Fig. 9

See information in Figure 18 for Vertical(V) and Horizontal(H) maximums and minimums. The same amounts apply for flexible venting.

BGFVK Vent Kit Shown (recommended for use with cabinet mantels)

Vertical (V) Horizontal (H)

37" min. 10" max.

Figure 16 - Horizontal Termination Con- figuration for Rigid Venting

Figure 18 - Horizontal Termination Using Flexible Venting

Show 5 more labels / short text on this page
® · Horizontal Venting · Horizontal Venting · Horizontal Venting · 10 106517
Page 11 of the Desa BHDV41PC user manual — Horizontal Termination Configurations
Page 11 · click to enlarge
Page 11
Desa BHDV41PC — Horizontal Termination Configurations diagram (page 11)
Fig. 10 · Horizontal Termination Configurations

Vertical (V) Horizontal (H1) Horizontal (H1) +

5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max.

Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows

5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max.

Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace

11 106517

Page 12 of the Desa BHDV41PC user manual — INSTALLATION FOR VERTICAL TERMINATION
Page 12 · click to enlarge
Page 12

VENTING INSTALLATION Continued

Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in Figure 12 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceil- ing or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 22). 2. Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7. Be sure all pipe and elbow connections are fully twist- locked (see Figure 11, page 9). 3. Cut a hole in the roof using the locating hole as a center point. (Cover any ex- posed open vent pipes before cutting hole in roof.) The 10"x10" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combus- tible materials. Frame the opening as shown in Figure 12 on page 9.

4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 21). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less re- striction to the flow of the flue gases and intake air. 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 21. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the mini- mum building code requirements de- scribed in Figure 8 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs, and other similar fac- tors may cause poor draft or down-draft- ing in high winds. Increasing the vent height may solve this problem. 7. Twist-lock the vent cap onto the last section of vent pipe and seal outer pipe connection with high temperature sili- cone sealant as specified in the second warning statement on page 7. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclo- sure with standard construction material. Make sure and meet the minimum allowable clear- ances to combustibles. Do not fill any of the required air spaces with insulation.

INSTALLATION FOR VERTICAL TERMINATION

1. Determine the route your vertical vent- ing will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 21) to avoid cutting loadbearing members. Note: Pay spe- cial attention to these installation in- structions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclo- sures, attic rafters, etc. Do not pack air spaces with insulation. Also note maxi- mum vertical rise of the venting sys- tem and any maximum horizontal off- set limitations. Offsets must fall within the parameters shown in Figure 8 on page 6. 2. Set the fireplace in desired location. Drop a plumb line down from the ceil- ing to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceil- ing. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.

If area above is a room, install firestop above framed hole.

Cathedral Ceiling Installation 1. Remove shingles or other roof cover- ing as necessary to cut the rectangular hole for the support box. Mark the out- line of the cathedral ceiling support box on the roof sheathing using the locat- ing hole as a center point. 2. Cut the hole 1/8" larger than the sup- port box outline (see Figure 23, page 13).

If area above is not a room, install firestop below framed hole.

Figure 21 - Offset with Wall Strap and 45° Elbows

Figure 22 - Installing Firestop

Show 6 more labels / short text on this page
® · Roof Flashing · Wall Strap · 45° Elbow · Ceiling Firestop · 12 106517
Page 13 of the Desa BHDV41PC user manual — Vertical Termination Configurations
Page 13 · click to enlarge
Page 13

VENTING INSTALLATION Continued

Vertical Termination Configurations

Figures 25 through 28 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.

3. Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 23). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing. 4. Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 24). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box. 5. Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.

Venting with Two 90° Elbows

Vertical (V) Horizontal (H1) +

Horizontal (H2)

5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max.

20' max. 8' max.

Cathedral ceiling support box

Figure 25 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two Horizontal Runs

2" minimum below finished ceiling

Venting with One 90° Elbow

Vertical (V) Horizontal (H)

Cut hole 1/8" larger than support box when projected onto roofline

5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max.

Figure 23 - Cathedral Ceiling Support Box Installation

20' max. 8' max.

Non-hardening Mastic under all edges of support box before nailing Figure 24 - Installed Cathedral Ceiling Support Box

Figure 26 - Vertical Rigid Venting Configuration Using One 90° Elbow

Level · Continued · 13 106517

Page 14 of the Desa BHDV41PC user manual — Vertical Termination Configurations
Page 14 · click to enlarge
Page 14
Desa BHDV41PC — Vertical Termination Configurations diagram (page 14)
Fig. 11 · Vertical Termination Configurations

5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max.

Figure 28 - Vertical Rigid Venting Con- figuration With No Horizontal Run

Figure 27 - Vertical Rigid Venting Configuration Using Two 90° Elbows

® · 14 106517

Page 15 of the Desa BHDV41PC user manual — SIMPSON DURA-VENT GS 4" x 6 5 / 8 "
Page 15 · click to enlarge
Page 15

VENTING INSTALLATION Continued

Vanguard Rigid Venting (Cont.)

Vanguard Flexible Venting Number Description BFGFVK Basic Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 2' Flexible Pipe, 4" x 2' Flexible Pipe, Wall Thimble, Horizontal Termination, (2) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, and 10 Screws FGFVK Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination, (4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws D1040 7" x 25' Coaxial Flex Pipe with Spacer Springs D3080 Rectangular Horizontal Flex Termination Cap

Number Description SVK Snorkel Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° El- bow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, 36" Snorkel Termination, RTV Sili- cone and 28 Screws RVF Roof Rigid Vent Kit Includes: Flue Restrictor, Storm Collar, 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 2' Galva- nized Pipe, 7" Adjustable Gal- vanized Pipe (7-12"), Firestop Support, Roof Flashing, RTV Silicone, Vertical Termination, and 26 screws D1000 7" x 12" Galvanized Coaxial Pipe (6 pcs.) D1010 7" x 24" Galvanized Coaxial Pipe (6 pcs.) D1020 7" x 48" Galvanized Coaxial Pipe (6 pcs.) D1030 7" Adjustable (7-12") Galvanized Coaxial Pipe (6 pcs.) D1050 7" x 6" Galvanized Coaxial Pipe (6 pcs.) D2000 7" x 90° Elbow (6 pcs.) D2010 7" x 45° Elbow (6 pcs.) D2020 7" x 30° Elbow (6 pcs.) D2030 7" x 60° Elbow (6 pcs.) D3000 Wall Strap/Offset Support (6 pcs.) D3010 Storm Collar (6 pcs.) D3020 Wall Thimble (6 pcs.) D3050 Vertical Restrictor (6 pcs.) D3060 Ceiling Firestop/Support (6 pcs.) D3070 Rectangular Horizontal Rigid Vent Termination Cap D3071 Adjustable Horizontal Rigid Vent Termination Cap D3090 Cathedral Ceiling Support Box D4000 Roof Flashing 6/12-9/12 D4010 Roof Flashing 9/12-12/12 D4020 Flex Connector (6 pcs.) D4030 Flex Wall Thimble (6 pcs.) D4040 4" Hose Clamp (6 pcs.) D4050 7" Hose Clamp (6 pcs.) D5000 Wood/Vinyl Siding Standoff (6 pcs.)

HIGH ALTITUDE INSTALLATION

Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet.

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities.

SIMPSON DURA-VENT GS 4" x 6 5 / 8 "

Consult your local gas company to help de- termine the proper orifice for your location.

Number Description Available from DESA International: SD2040 Simpson Dura-Vent GS 30° Elbow (6 pcs.) SD2050 Simpson Dura-Vent GS 60° Elbow (6 pcs.) Available from Simpson Dura-Vent only: 902 7" x 48" Pipe 903 7" x 36" Pipe 904 7" x 24" Pipe 906 7" x 12" Pipe 907 7" x 9" Pipe 908 7" x 6" Pipe 911 7" Adjustable (11"-14 5/8") Pipe 940 Wall Thimble 941 Cathedral Ceiling Support Box 943 Roof Flashing 0/12-6/12 943S Roof Flashing 7/12-12/12 945 7" x 45° Elbow 950 Vinyl Siding Standoff 953 Storm Collar 963 Ceiling Firestop 981 36" Snorkel Termination 984 Horizontal Termination Vent Cap 988 Wall Strap 990 7" x 90° Elbow 991 Vertical High Wind Termination

For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Service Department at 1-800-DESA- LOG (1-800-337-2564).

PARTS LISTS FOR VENTING KITS AND COMPONENTS Vanguard Rigid Venting Number Description BGFVK Basic Ground Floor Rigid Vent Kit Includes: 7" x 60° Elbow, Ex- tended Adjustable Horizontal Termination, Wall Thimble and 14 Screws CVK Corner Vent Kit Includes: 7" x 30º Elbow, 7" x 90º Elbow, 7" Adjustable Galvanized Pipe (7-12"), 6" Pipe, Wall Thimble, Horizontal Termina- tion, RTV Silicone and 20 Screws BVK Basement Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° El- bow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws

15 106517

Page 16 of the Desa BHDV41PC user manual — Attaching Thermal Switch to DA3610TA ThermostaticallyControlled Blower
Page 16 · click to enlarge
Page 16

CHECK GAS TYPE

Installing GA3700/DA3610TA Blowers

FIREPLACE INSTALLATION

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type.

IMPORTANT: For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 30 through 31, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines. 1. Open lower louver panel or remove for easier access. 2. Place the blower against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 30, page 17). Using the two screws provided, mount blower and tighten screws securely. Note: For DA3610TA, make sure the thermal switch is comfortably under the back of the firebox as shown in Figure 31, page 17. 3. Be sure to securely attach all wire ter- minals to terminals on blower motor (and thermal switch where applicable) and that the screw retaining the green ground wire is tight. 4. Remove screws securing the plate con- taining the ON/OFF switch to the bot- tom of the firebox and set aside. 5. Place speed control against back of this plate and push the plastic control shaft through opening (see Figure 32, page 17). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the plate. Place control knob provided onto shaft (see Figure 32, page 17). 7. Replace plate containing switches and tighten screws securely.

Desa BHDV41PC — CHECK GAS TYPE diagram (page 16)
Fig. 12

INSTALLING OPTIONAL BLOWER ACCESSORY

Attaching Thermal Switch to DA3610TA ThermostaticallyControlled Blower

When installing the DA3610TA thermostati- cally-controlled blower accessory, you must first secure the thermal switch to the blower. 1. Remove the two hex head screws on the blower assembly as shown in Figure 29. 2. Place the green wire between the bot- tom hole on the thermal switch bracket and the bottom hole on the blower as- sembly. Insert one of the hex screws into all three pieces and tighten. 3. Insert the top screw through the ther- mal switch bracket and into the blower assembly. Tighten screw. 4. Connect the blue wire on the blower assembly to the right side of the ther- mal switch. 5. Connect the black wire to the left side of the thermal switch.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or fram- ing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 4.

Place the fireplace into position and shim with noncombustible material if needed. Nail the side flanges to the framing to secure the unit in place. There are two floor brack- ets included with each unit. Use these as an alternative method of securing the fireplace.

Thermal Switch with Bracket

Desa BHDV41PC — Attaching Thermal Switch to DA3610TA ThermostaticallyControlled Blower diagram (page 16)
Fig. 13 · Attaching Thermal Switch to DA3610TA Thermostaticall…

Figure 29 - Attaching Thermal Switch to DA3610TA Thermostatically-Controlled Blower Accessory

Show 4 more labels / short text on this page
® · White Wire · Hex Head Screws · 16 106517
Page 17 of the Desa BHDV41PC user manual — CHECK GAS TYPE
Page 17 · click to enlarge
Page 17

FIREPLACE INSTALLATION Continued 8. Plug in blower power cord. a. If your fireplace system is installed

9. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing.

as a freestanding unit with an ac- cessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. In- stall one plastic bushing provided into the 1 1/2" hole in the outer cas- ing through which the power cord will exit. Install the second plastic bushing provided into the floor sup- port bracket if exiting through the right side (see Figure 33). Route power cord through (both) plastic bushing(s) and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox. b. If your fireplace system installation

11. Connect or reconnect gas supply to fireplace per Connecting Fireplace to Gas Supply on page 19 of this manual.
10. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (see Figure 33).

is recessed and/or pre-wired, a qualified installer must make all elec- trical connections for the outlet kit included with the fireplace.

Figure 31 - Locating Thermal Switch Against Back of Firebox

Lower Rear Wall of Firebox Wrapper

Figure 32 - Attaching Speed Control to Firebox

Blower Speed Control Bracket

Figure 30 - Mounting Blower to Firebox

Figure 33 - Installing Plastic Bushing and Wiring Diagram Sticker

Show 19 more labels / short text on this page
Firebox Bottom · Firebox Back · Firebox Flange · Blower · Thermal Switch · Thermal Switch · Side View · Speed Control · Control Knob · Control Shaft · Locknut · Lower Louver Panel · Blower · Exhaust Port Screws · Top Mounting Tab · Plastic Bushing · Wiring Diagram · Continued · 17 106517
Page 18 of the Desa BHDV41PC user manual — Installation Items Needed
Page 18 · click to enlarge
Page 18

FIREPLACE INSTALLATION Continued

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

INSTALLING GAS PIPING TO FIREPLACE LOCATION

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 35).

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 35. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

Installation Items Needed

  • Before installing fireplace, make sure you have the items listed below.
  • external regulator (supplied by installer)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench
  • approved flexible gas line with gas connector (if allowed by local codes) (not provided)

Figure 34 - External Regulator with Vent Pointing Down (Propane/LP Only)

CSA/AGA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Desa BHDV41PC — Installation Items Needed diagram (page 18)
Fig. 14 · Installation Items Needed

* An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. Purchase the CSA/AGA design-certi- fied equipment shutoff valve from your dealer.

Natural - From Gas Meter (5" W.C. to 10.5" W.C. Pressure )

Propane/LP - From External Regulator (11" W.C. to 14" W.C. Pressure)

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 34. Pointing the vent down protects it from freezing rain or sleet.

Figure 35 - Gas Connection * The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

Show 6 more labels / short text on this page
® · Propane/LP Supply Tank · External Regulator · Vent Pointing Down · Sediment Trap/Drip Leg · 18 106517
Page 19 of the Desa BHDV41PC user manual — Pressure Testing Gas Supply Piping System
Page 19 · click to enlarge
Page 19

FIREPLACE INSTALLATION Continued

CHECKING GAS CONNECTIONS

3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 4. Check all joints of gas supply piping system. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

  • 5/16" hex socket wrench or nut-driver
  • sealant (resistant to propane/LP gas, not provided) 1. Open lower louver door panel by gently pulling forward. 2. Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace. 3. Attach a 45 ° flare union gas connector to flexible gas line from gas supply (see Figure 36). Connect flare union to flexible gas line attached to gas regulator of fireplace (see Figure 36). 4. Check all gas connections for leaks. See Checking Gas Connections.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected.

To Fireplace Gas Valve

Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace Flexible Gas Line from Equipment Shutoff Valve Provided by Installer

To Gas Supply (Natural)

To External Regulator (Propane/LP) Figure 36 - Attaching Flexible Gas Lines Together

Show 4 more labels / short text on this page
Flare Union · Equipment Shutoff Valve · Continued · 19 106517
Page 20 of the Desa BHDV41PC user manual — CHECKING GAS CONNECTIONS
Page 20 · click to enlarge
Page 20
Desa BHDV41PC — CHECKING GAS CONNECTIONS diagram (page 20)
Fig. 15

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 37). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 3. Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 38 for pro- pane/LP or Figure 39 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Desa BHDV41PC — CHECKING GAS CONNECTIONS diagram (page 20)
Fig. 16

Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 37). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 38 for propane/LP or Figure 39 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fire- place, pages 25 through 27). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 25).

Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace

Desa BHDV41PC — CHECKING GAS CONNECTIONS diagram (page 20)
Fig. 17

Figure 39 - Checking Gas Joints for Natural Gas Fireplace

® · 20 106517

Page 21 of the Desa BHDV41PC user manual — INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2
Page 21 · click to enlarge
Page 21

FIREPLACE INSTALLATION Continued

5. Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base. 6. Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 41).

W

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

R

Figure 42 - Thermostat Base Terminals “W” and “R”

7. Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 42). 8. Install the base to the wall with screws provided with thermostat. 9. Move the temperature adjustment back and forth to insure the bi-metal is free from restrictions. 10. Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.) 11. Set the temperature adjustment to the desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

1. Connect one terminal of the provided wire for the wall switch to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire ter- minals are in the positions on the unit as pictured in Figure 40. If wires are not connected as shown the switch will not work. 2. Route the wire through openings pro- vided on the sides of the burner sys- tem to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall.

1. Open lower louver panel. The valve is attached to the underside of the firebox assembly. 2. Disconnect from the valve the wires running from the ON/OFF switch. 3. Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remaining wire terminal to the TH ter- minal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 40. If wires are not connected as shown the thermostat will not work. 4. Route the wire through openings pro- vided on the sides of the fireplace to a convenient location to mount your ther- mostat (no outside wall). IMPORTANT: The wire may be short- ened but must not be lengthened. The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sun- light, fireplace, or heat and air condi- tioning ducts.

Figure 40 - Control Valve Terminals

Feed wires through rectangular slots

Figure 41 - Back View of Thermostat Base

Show 5 more labels / short text on this page
Terminal “W” · Terminal “R” · To Wall Thermostat · Continued · 21 106517
Page 22 of the Desa BHDV41PC user manual — REMOVING/REPLACING GLASS DOOR
Page 22 · click to enlarge
Page 22

FIREPLACE INSTALLATION Continued

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

1. Remove the upper louver panel by lifting upward and out (see Figure 43). 2. Remove the screws from the three tabs at the top of the glass door while holding door securely keeping it from falling forward. 3. Grasp door by both sides and ease it upward off of the lower bracket (see Figure 44). 4. To replace glass door, follow the above instructions in reverse.

Lower Bracket for Glass Door Assembly

Figure 44 - Removing/Replacing Glass Door

Desa BHDV41PC — REMOVING/REPLACING GLASS DOOR diagram (page 22)
Fig. 18

Figure 43 - Removing Top Louver Panel

Show 4 more labels / short text on this page
® · Screw · Glass Door Assembly · 22 106517
Page 23 of the Desa BHDV41PC user manual — INSTALLING OPTIONAL BRICK LINER D8037A/D8041
Page 23 · click to enlarge
Page 23

FIREPLACE INSTALLATION Continued

INSTALLING OPTIONAL BRICK LINER D8037A/D8041

Left Side Brick Panel

This brick liner kit is optional. You may purchase brick liner from your local dealer or see Accessories, pages 38 and 39.

Figure 45 - Installing Left Side Brick Panel

1. Remove glass door. See Removing/Re- placing Glass Door, page 22. 2. If installing brick liner in new fireplace, go to step 3. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material. 3. Install left side brick panel first by slid- ing it between the grate and the side of the firebox (see Figure 45). 4. Slide the left retainer bracket against the left side brick panel. Loosely se- cure the bracket screw. This secures the left side brick panel. 5. Install the right brick panel using the same method described in step 3. 6. Slide the right retainer bracket against the right side brick panel. Loosely se- cure the bracket screw. This secures the right side brick panel. 7. Install rear brick panel. Rest bottom edge of panel on back edge of grate (see Figure 46). 8. Loosely secure retainer brackets to grate. Brackets are adjustable left to right to allow proper placement of panel. These will hold rear panel in place. 9. Tighten all bracket screws. 10. Follow instructions on page 24 to install logs, lava rock, and ember material. 11. Replace glass door (see page 22).

Figure 46 - Installing Rear Brick Panel and Retainer Brackets

Show 4 more labels / short text on this page
Rear Brick Panel · Retaining Brackets · Continued · 23 106517
Page 24 of the Desa BHDV41PC user manual — INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS
Page 24 · click to enlarge
Page 24

FIREPLACE INSTALLATION Continued

7. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 52). This will create the glowing ember ap- pearance as the flame touches the em- ber material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided. 8. Replace the glass door. See Removing/ Replacing Glass Door, page 22.

INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS

Figure 49 - Installing Log No. 3

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

Remove glass door. See Removing/Replacing Glass Door, page 22. Install logs according to instructions for fireplace model numbers. 1. Place log #1 (back log) on top of grate. Make sure the notches in the bottom of the log fit over the grate (see Figure 47). 2. Rest log #2 (large front log) on the pins on the front part of the grate (see Figure 48). 3. Place log #3 (“C”-shaped crossover log) onto the rear and front logs. Make sure it is seated properly on the smooth surface on the front log and on the pin on the back log as shown in Figure 49. 4. Place log #4 (small, round log) on the pin on the right side of front log as shown in Figure 50. 5. Place log #5 (small log) onto the front left part of the grate making sure the notches fit over the prongs of the grate (and hole over pin on 41" set). See Figure 51. 6. Place lava rock along sides and front of firebox bottom in areas that are vis- ible only. It is not necessary to use all of the lava rock provided.

Figure 50 - Installing Log No. 4

Figure 47 - Installing Log No. 1

Figure 51 - Installing Log No. 5

Figure 48 - Installing Log No. 2

Figure 52 - Placing Ember Material on Burner

Show 4 more labels / short text on this page
® · 41" Set Only · Ember Material · 24 106517
Page 25 of the Desa BHDV41PC user manual — P
Page 25 · click to enlarge
Page 25

OPERATING FIREPLACE

6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column one. If you don't smell gas, go to the next step. 7. The pilot is located by the main burner and should not require accessing for lighting. 8. Turn gas control knob counterclockwise to “PILOT”.
3. Turn off all electrical power to the appliance if service is to be performed. 4. Push in gas control knob slightly and turn clockwise to “OFF”. 5. Close lower louver panel.

FOR YOUR SAFETY

READ BEFORE

Shutting Off Burners Only (pilot stays lit)

LIGHTING

You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn gas control knob clockwise

  • 9. Push in gas control knob all the way and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
  • If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.
  • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 10. Turn gas control knob counterclockwise to “ON”.

to the PILOT position. 2. Set selector switch in the OFF position.

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

MANUAL LIGHTING

PROCEDURE 1. Remove glass door (see Removing/ Replacing Glass Door, page 22). 2. Follow steps 1 through 8 under Light- ing Instructions. 3. Depress gas control knob and light pilot with match. 4. Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release gas control knob. Now follow steps 10 through 14, column 2. 5. Replace glass door (see Removing/ Replacing Glass Door, page 22).

11. Turn on all electric power to the fireplace. 12. Turn the ON/OFF switch to ON position. 13. This valve is equipped with a HI/LO feature. Set fireplace input as desired. 14. Close lower louver panel.

OPTIONAL REMOTE

OPERATION Note: All remote control accessories must be purchased separately (See Accessories on pages 38 and 39). Follow instructions included with the remote control.

Thermostat Control Operation

TO TURN OFF GAS

TO APPLIANCE

(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

1. Open lower louver panel. 2a. Turn ON/OFF switch to “OFF”. 2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

LIGHTING INSTRUCTIONS 1. STOP! Read the safety information in column one. 2. Open lower louver panel. 3. Turn ON/OFF switch to “OFF”. 4. Turn off all electric power to the fireplace. 5. Push in gas control knob slightly and turn clockwise to “OFF”.

Gas Control Knob Variable Control Knob

P

O

T

O

H

O

F

F

N

O

Figure 53 - Control Valve

Piezo Ignitor · Continued · 25 106517

Page 26 of the Desa BHDV41PC user manual — REMOTE
Page 26 · click to enlarge
Page 26

OPERATING FIREPLACE Continued

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down. IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off. 3. To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

OPERATING OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

1. After lighting, let pilot flame burn for about one minute. Turn gas control knob on the control valve to ON posi- tion. Turn variable control knob any- where between HI and LO. Slide the selector switch to the REMOTE posi- tion. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with either optional hand-held remote control unit. IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation.

Both the GA3700 manual blower and the DA3610TA thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610TA Only: If you are using DA3610TA blower with optional thermostat (wall mount or remote con- trol) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Blower Control Knob (Optional Accessory)

GHRC Series Operation: 2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

ON OFF

O

N

O

H

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

REMOTE

T

O

P

F

F

O

ON

OFF

Gas Control Knob in On Position

  • GHRCTA Series Operation: 2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 55). The lights to the left of the button will show AUTO, ON, or OFF.
  • In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
  • In the AUTO mode, the thermostat in the hand-held remote unit controls the room temperature. To increase the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

Selector Switch in Remote Position (Optional Remote Control)

Figure 54 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

Increases Room Temperature in AUTO Mode

Decreases Room Temperature in AUTO Mode

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Turns Burners On or Off and Allows You to Choose the Auto Setting

Figure 55 - Hand-Held Thermostat Remote Control Unit Selections (GHRCTA Series Only)

Show 4 more labels / short text on this page
® · Variable Control Knob · Shows Tempera- ture Setting · 26 106517
Page 27 of the Desa BHDV41PC user manual — OPERATING OPTIONAL GWMS2
Page 27 · click to enlarge
Page 27

OPERATING FIREPLACE Continued

INSPECTING BURNERS

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

Check pilot flame pattern and burner flame patterns often.

OPERATING OPTIONAL GWMT1

If the vent configuration is installed incor- rectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.

PILOT ASSEMBLY

WALL MOUNTED

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

THERMOSTAT

  • Figure 57 shows a typical flame pattern for these models. If burner flame pattern differs from that described:
  • turn fireplace off (see To Turn Off Gas to Appliance , page 25)
  • see Troubleshooting , pages 29 through 31

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 56. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

Light the fireplace as instructed in Light- ing Instructions on page 25. Set wall ther- mostat to desired temperature.

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling. Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermo- stat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

  • If your pilot assembly does not meet these requirements:
  • turn fireplace off (see To Turn Off Gas to Appliance , page 25)
  • see Troubleshooting , pages 29 through 31

Figure 57 - Typical Flame Pattern

OPERATING OPTIONAL GWMS2

WALL MOUNTED

SWITCH Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.

Figure 56 - Pilot Assembly

Show 7 more labels / short text on this page
Thermopile · 3/8" to 1/2" · Pilot Burner · 1/8" · Thermocouple · Piezo Ignitor · 27 106517
Page 28 of the Desa BHDV41PC user manual — GLASS DOOR
Page 28 · click to enlarge
Page 28

CLEANING AND MAINTENANCE

  • LOGS
  • If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers , page 24, to properly replace logs.
  • Use a vacuum cleaner to remove any carbon build-up on logs.
  • Replace log(s) if broken. See Replacement Parts on page 32.
  • Replace ember material periodically as needed. See Replacement Parts on page 32.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person. 2. Remove the vent cap and shine a flash- light into the vent. Remove any foreign material. 3. Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system be- ing exposed to cold weather. 4. Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 22). Vacuum all glass pieces with a shop vac.

GLASS DOOR

Use only the ceramic glass door replace- ment intended for this fireplace (see Re- placement Parts, page 32 for detail on or- dering). No substitutions may be made. See Removing/Replacing Glass Door, page 22 for instructions for replacing glass door.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-amonia, non-abra- sive household cleaner and warm water after the first two weeks of operation. There- after, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 22 of this manual when removing glass door for cleaning.

  • PILOT AND BURNERS
  • Remove ember material before cleaning burners and replace when cleaning is complete.
  • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.
  • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

® · 28 106517

Page 29 of the Desa BHDV41PC user manual — OBSERVED PROBLEM
Page 29 · click to enlarge
Page 29

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace pilot assembly 7. Replace pilot assembly
3. Piezo ignitor nut is loose
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong

When ignitor button is pressed, there is spark at pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Gas control knob not in PILOT position 3. Gas control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn gas control knob to PILOT position 3. Press in gas control knob while in PILOT position 4. Continue holding down gas control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company
5. Depleted gas supply (propane/LP models only) 6. Pilot is clogged
6. Clean pilot (see Cleaning and Maintenance , page 28) or replace pilot assembly 7. Replace gas control
7. Gas regulator setting is not correct

Pilot lights but flame goes out when control knob is released

1. Gas control knob not fully pressed in 2. Gas control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged
1. Press in gas control knob fully 2. After pilot lights, keep gas control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local gas company

B) Clean pilot (see Cleaning and Maintenance, page 28) or replace pilot assembly

5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace control valve

www.desatech.com Continued

29 106517

Page 30 of the Desa BHDV41PC user manual — OBSERVED PROBLEM
Page 30 · click to enlarge
Page 30

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1. Burner orifice clogged
1. Clean burner (see Cleaning and Maintenance , page 28) or replace burner orifice 2. Contact local propane/LP or natural gas company 3. Reconnect leads (see Wiring Diagram, page 32) 4. Replace thermopile
2. Inlet gas pressure is too low
3. Thermopile leads disconnected or improperly connected 4. Thermopile is defective
1. Manifold pressure is too low
1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance , page 28) or replace burner orifice
2. Burner porting or orifice clogged

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 28) or replace burner orifice 2. Replace damaged burner 3. Replace gas control
2. Damaged burner 3. Gas regulator defective

Slight smoke or odor during initial operation

1. Residues from manufacturing processes and logs curing
1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1. Turning gas control knob to HI position when burner is cold 2. Air in gas line
1. Turn gas control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP or natural gas company 3. Clean burner (see Cleaning and Maintenance , page 28) or replace burner orifice
3. Dirty or partially clogged burner orifice
1. Flame impingement on logs
1. Adjust the log set so that the flame does not excessively impinge on it 2. Inspect the opening at the base of the burner to see that it is NOT packed with any type of material
2. Debris around burner air mixer

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common. If noise is excessive, contact qualified service person

Remote does not function

1. Battery is not installed or battery power is low
1. Replace 9-volt batteries in receiver and remote control

www.desatech.com

Show 4 more labels / short text on this page
® · Delayed ignition burner · Glass soots · 30 106517
Page 31 of the Desa BHDV41PC user manual — OBSERVED PROBLEM
Page 31 · click to enlarge
Page 31

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted odors

1. Gas leak. See Warning statement above
1. Locate and correct all leaks (see Checking Gas Connections , pages 19 and 20)

Fireplace shuts off in use

1. High or gusting winds

1. Fireplace has been tested for up to 40mph winds. However, extreme con- ditions may occur. See Lighting Instruc- tions on page 25 2. Contact local propane/LP or natural gas company 3. Clean pilot (see Cleaning and Mainte- nance, page 28) 4. Locate and correct all leaks (see Check- ing Gas Connections,pages 19 and 20) 5. Horizontal vent termination should slope down only enough to prevent any water from entering the unit. The maximum downward slope of the vent termination is 1/4" for any horizontal run 6. Tighten glass

2. Low line pressure
3. Pilot is partially clogged
4. Inner vent pipe leaking exhaust gasses into system 5. Horizontal vent improperly pitched
6. Glass too loose and air tight gasket leaks in corners after usage 7. Bad thermopile or thermocouple 8. Improper vent cap installation
7. Replace faulty component 8. Check for proper installation and freedom from debris or blockage

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement above 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , pages 19 and 20) 2. Replace control valve

Gas odor during combustion

1. Gas leak. See Warning statement above
1. Locate and correct all leaks (see Checking Gas Connections , pages 19 and 20)

Dark residue on logs or inside of fireplace

1. Improper log placement
1. Properly locate logs (see Installing Logs, Lava Rock, and Glowing Ember , page 24) 2. Clean out air holes at burner inlets. Periodically repeat as needed 3. Remove blockage or replace burner
2. Air holes at burner inlet blocked
3. Burner flame holes blocked

www.desatech.com

31 106517

Page 32 of the Desa BHDV41PC user manual — TECHNICAL SERVICE
Page 32 · click to enlarge
Page 32

REPLACEMENT PARTS

WIRING DIAGRAM

  • PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your fireplace
  • how fireplace was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory.

Variable Fan Switch Fan Switch

(N.O.)

110/115 V.A.C.

  • PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA International, have ready
  • model number of your fireplace
  • the replacement part number

Figure 58 - Blower Wiring Diagram for Thermostat-Controlled Models

  • SERVICE HINTS When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • fireplace will not produce specified heat
  • propane/LP gas supply might be low (propane/LP units only)

TECHNICAL SERVICE

  • When Gas Quality Is Bad
  • pilot will not stay lit
  • burners will produce flames and soot
  • fireplace will backfire when lit

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier.

You can also visit DESA International’s technical service web site at www.desatech.com.

Show 10 more labels / short text on this page
® · Off · 1 2 Black · On · Blue · Motor Black · Blower · White · Green · 32 106517
Page 33 of the Desa BHDV41PC user manual — BHDV37NC BHDV37PC BHDV41NC BHDV41PC
Page 33 · click to enlarge
Page 33

SPECIFICATIONS

BHDV37NC BHDV37PC BHDV41NC BHDV41PC

17,000/24,000 Btu/h 17,000/22,000 Btu/h 18,000/26,000 Btu/h 19,000/24,000 Btu/h

Gas Type Natural Propane/LP Natural Propane/LP

Ignition Piezo

Manifold Pressure 3.5" w.c. 10.0" w.c. 3.5" w.c. 10.0" w.c.

Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. 4.5" w.c. 11.0" w.c.

Thermal Efficiency 70%

Fireplace 33" x 37" x 18 1/2" 33" x 37" x 18 1/2" 35" x 41" x 18 1/2" 35" x 41" x 18 1/2" 838 x 940 x 470mm 838 x 940 x 470mm 838 x 1041 x 470mm 838 x 1041 x 470mm

Carton 36" x 39" x 19 1/2" 36" x 39" x 19 1/2" 36" x 43" x 19 1/2" 36" x 43" x 19 1/2" 914 x 991 x 495mm 914 x 991 x 495mm 914 x 1092 x 495mm 914 x 1092 x 495mm

Fireplace 132 lbs/60 kg 132 lbs/60 kg 142 lbs/64 kg 142 lbs/64 kg Shipping 135 lbs/61 kg 135 lbs/61 kg 145 lbs/66 kg 145 lbs/66 kg

Dimension, Inches/mm (HxWxD) · Weight, lbs/kg · 33 106517

Page 34 of the Desa BHDV41PC user manual — REPLACEMENT PARTS
Page 34 · click to enlarge
Page 34
Desa BHDV41PC — REPLACEMENT PARTS diagram (page 34)
Fig. 19

® · 34 106517

Page 35 of the Desa BHDV41PC user manual — PARTS AVAILABLE - NOT SHOWN
Page 35 · click to enlarge
Page 35

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

DIRECT-VENT FIREPLACE

BHDV37NC BHDV41NC

KEY NO. PART NUMBER DESCRIPTION QTY.

KEY NO. PART NUMBER DESCRIPTION QTY.

33 104515-02 Wire for Wall Switch - 15' 1 34 107165-01 Log Set - 37" 1 107164-01 Log Set - 41" 1 34-1 107344-02 Rear Log - 37" 1 107344-01 Rear Log - 41" 1 34-2 107345-02 Front Log - 37" 1 107345-01 Front Log - 41" 1 34-3 107346-01 Crossover Log - 37" & 41" 1 34-4 107347-02 Log Piece - 37" 1 107347-01 Log Piece - 41" 1 34-5 107348-01 Top Small Log - 37" & 41" 1 35 M10908-2 Screw 6 36 M12461-65 Screw 3 37 H5C4-20B Bolt 2 38 NTC-4C Locknut 2 39 M12461-26 Screw 4 40 104555-02CJ Grate Assembly - 37" 1 104555-01CJ Grate Assembly - 41" 1 41 105775-04 Glass Door Assy - 37" 1 105775-02 Glass Door Assy - 41" 1 42 104490-02CJ Baffle - 37" 1 104490-01CJ Baffle - 41" 1 43 104576-02CK Front Assembly - 37" 1 104576-03CK Front Assembly - 41" 44 104615-02 Insulation - 37" 1 105628-01 Insulation - 41" 1 45 104313-01 Hinge, Pin 1 46 104313-02 Hinge, Pin 1 47 104954-01 Screw 3 48 104963-01 Washer 3 49 104955-01 Nut 3 50 103769-01 Duplex Outlet 1 51 104602-01 Duplex Outlet Cover 1

1 104547-02 Top Outer Casing - 37" 1 104547-03 Top Outer Casing - 41" 1 2 104474-02 Outer Casing - 37" 1 104474-03 Outer Casing - 41" 1 3 104548-02 Bottom Outer Casing - 37" 1 104548-01 Bottom Outer Casing - 41" 1 4 104479-08BR Firebox Assembly - 37" 1 104479-07BR Firebox Assembly - 41" 1 5 M11084-26 Screw, Hex 52 6 M11084-46 Screw, Hex 13 7 102455-04 Louver, Extruded - 37" 2 102455-03 Louver, Extruded - 41" 2 8 104443-01 Firebox Support, Right 1 9 104486-01 Firebox Support, Left 1 10 104482-01 Switch Bracket 1 11 104483-01 Floor Mounting Bracket 2 12 104491-01 Relief Cover 1 13 104518-01 Relief Cover Gasket 1 14 104527-01 Relief Spring 2 15 104528-01 Relief Washer 2 16 104537-01 Valve Bracket 1 17 104496-01 SIT Valve, Natural 1 18 104497-01 SIT Pilot, Natural 1 19 104498-01 Thermocouple 1 20 104499-01 Thermopile 1 21 104500-01 Ignitor 1 22 104501-01 Ignitor Bracket 1 23 104502-01 Ignitor Screw 1 24 104503-01 Ignitor Wire 1 25 104504-01 Burner 1 26 104506-01 Orifice - 37" 1 104506-03 Orifice - 41" 1 27 104507-01 Brass Elbow 1 28 104508-01 Brass Fitting 2 29 104509-01 Aluminum Tubing Assy 1 30 104510-01 Pilot Tubing Assy 1 31 101628-04 Flexible Connector 1 32 105325-01 Burner Baffle 1

PARTS AVAILABLE - NOT SHOWN

GA6060 Lava Rock 1 104529-01 Ember Material 1 104512-01 Ball Valve 1

35 106517

Page 36 of the Desa BHDV41PC user manual — REPLACEMENT PARTS
Page 36 · click to enlarge
Page 36
Desa BHDV41PC — REPLACEMENT PARTS diagram (page 36)
Fig. 20

® · 36 106517

Page 37 of the Desa BHDV41PC user manual — PARTS AVAILABLE - NOT SHOWN
Page 37 · click to enlarge
Page 37

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

DIRECT-VENT FIREPLACE

BHDV37PC BHDV41PC

KEY NO. PART NUMBER DESCRIPTION QTY.

KEY NO. PART NUMBER DESCRIPTION QTY.

1 104547-02 Top Outer Casing - 37" 1 104547-03 Top Outer Casing - 41" 1 2 104474-02 Outer Casing - 37" 1 104474-03 Outer Casing - 41" 1 3 104548-02 Bottom Outer Casing - 37" 1 104548-01 Bottom Outer Casing - 41" 1 4 104479-08BR Firebox Assembly - 37" 1 104479-07BR Firebox Assembly - 41" 1 5 M11084-26 Screw, Hex 52 6 M11084-46 Screw, Hex 13 7 102455-04 Louver, Extruded - 37" 2 102455-03 Louver, Extruded - 41" 2 8 104443-01 Firebox Support, Right 1 9 104486-01 Firebox Support, Left 1 10 104482-01 Switch Bracket 1 11 104483-01 Floor Mounting Bracket 2 12 104491-01 Relief Cover 1 13 104518-01 Relief Cover Gasket 1 14 104527-01 Relief Spring 2 15 104528-01 Relief Washer 2 16 104537-01 Valve Bracket 1 17 104496-02 SIT Valve, Propane/LP 1 18 104497-02 SIT Pilot, Propane/LP 1 19 104498-01 Thermocouple 1 20 104499-01 Thermopile 1 21 104500-01 Piezo Ignitor 1 22 104501-01 Ignitor Bracket 1 23 104502-01 Ignitor Screw 1 24 104503-01 Ignitor Wire 1 25 104504-02 Burner 1 26 104506-04 Orifice - 37" 1 104506-14 Orifice - 41" 1 27 104507-01 Brass Elbow 1 28 104508-01 Brass Fitting 2 29 104509-01 Aluminum Tubing Assy 1 30 104510-01 Pilot Tubing Assy 1 31 101628-04 Flexible Connector 1 32 105325-01 Burner Baffle 1

33 104515-02 Wire for Wall Switch 1 34 107165-01 Log Set - 37" 1 107164-01 Log Set - 41" 1 34-1 107344-02 Rear Log - 37" 1 107344-01 Rear Log - 41" 1 34-2 107345-02 Front Log - 37" 1 107345-01 Front Log - 41" 1 34-3 107346-01 Crossover Log - 37" & 41" 1 34-4 107347-02 Log Piece - 37" 1 107347-01 Log Piece - 41" 1 34-5 107348-01 Top Small Log - 37" & 41" 1 35 M10908-2 Screw 6 36 M12461-65 Screw 3 37 H5C4-20B Bolt 2 38 NTC-4C Locknut 2 39 M12461-26 Screw 4 40 104555-02CJ Grate Assembly - 37" 1 104555-01CJ Grate Assembly - 41" 1 41 105775-04 Glass Door Assy - 37" 1 105775-02 Glass Door Assy - 41" 1 42 104490-02CJ Baffle - 37" 1 104490-01CJ Baffle - 41" 1 43 104576-02CK Front Assembly - 37" 1 104576-03CK Front Assembly - 41" 1 44 104615-02 Insulation - 37" 1 105628-01 Insulation - 41" 1 45 104313-01 Hinge, Pin 1 46 104313-02 Hinge, Pin 1 47 104954-01 Screw 3 48 104963-01 Washer 3 49 104955-01 Nut 3 50 103769-01 Duplex Outlet 1 51 104602-01 Duplex Outlet Cover 1

PARTS AVAILABLE - NOT SHOWN

GA6060 Lava Rock 1 104529-01 Ember Material 1 104512-01 BallValve 1

37 106517

Page 38 of the Desa BHDV41PC user manual — BRICK LINER D8037A(37") D8041(41") (Not Shown)
Page 38 · click to enlarge
Page 38
Desa BHDV41PC — REPLACEMENT PARTS diagram (page 38)
Fig. 21

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCT SERIES

BRASS PERIMETER TRIM KIT - D9037(37")/GA6091(41") (Not Shown)

MANUAL BLOWER KIT GA3700

Manual-variable control blower accessory.

Optional three sided brass trim kit covers unfinished edges around fireplace. Provides a finished appearance with the class of brass.

Allows the fireplace to be operated in a manually or thermostatically-controlled mode. You can adjust your heat settings and turn the heater on or off without leaving the comfort of your easy chair.

BRASS LOUVER KIT D6037(37") D6041(41") (Not Shown)

WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown)

These louvers will give your fireplace an elegant look and allows you to customize your fireplace. They easily replace the stan- dard black louvers by screwing into place.

THERMOSTATICALLYCONTROLLED BLOWER KIT DA3610T

Allows easy wall access to the operation of your fireplace. This will allow you thermo- static control with the convenience of a wall switch.

DECORATIVE BRASS STRIP KIT - D5037(37")/D5041(41") (Not Shown)

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

WALL MOUNT ON/OFF SWITCH KIT - GWMS2 (Not Shown)

These strips have a magnetic backing which makes installation and removal quick and easy. They are designed to go at the top and bottom of the glass door. Note: Remove the plastic film covering on strips before install- ing on fireplace.

Allows the fireplace to be turned on and off with a wall switch.

BRICK LINER D8037A(37") D8041(41") (Not Shown)

RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SERIES

This brick liner adds a touch of style to your direct-vent fireplace and comes with easy to follow instructions for installation.

For all models. Allows the heater to be turned on and off conveniently.

® · 38 106517

Page 39 of the Desa BHDV41PC user manual — CABINET MANTEL WITH SQUARE LEG STYLING - UNFINISHED GM501U(37")/ GM103U(41")
Page 39 · click to enlarge
Page 39

ACCESSORIES Continued

CABINET MANTEL WITH SQUARE LEG STYLING - UNFINISHED GM501U(37")/ GM103U(41")

For use with all models. This birch-veneer mantel is unfinished and ready to stain or paint. Complete assembly instructions are in- cluded along with a three-sided brass trim kit.

39 106517

Page 40 of the Desa BHDV41PC user manual — INTERNATIONAL
Page 40 · click to enlarge
Page 40

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY DIRECT-VENT FIREPLACE

DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

106517-01 Rev. A 03/00 NOT A UPC

Model · Date Purchased · 106517 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa BHDV41PC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa BHDV41PC

Be the first to ask — other owners or our team will answer.

Original document

Desa BHDV41PC manual PDF

40 pages·1 MB·Outdoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…