Instruction/ maintenance manual of the product (V)T36NA Desa
Go to page of 44
For more information, visit www .desatech.com DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL NA TURAL GAS “TUDOR” MODELS (V)T36NA SERIES AND CTD V36NRA PROP ANE/LP GAS “T.
www .desatech.com 1 1 1250-01E 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Product Identication ...............
www .desatech.com 1 1 1250-01E 3 SAFETY INFORMA TION Continued This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 1 1250-01E 4 SAFETY INFORMA TION Continued 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 1 1250-01E 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • This replace requires a wall switch, hand-held remote or wall thermostat (millivolt) for opera - tion (see Accessories , page 36).
www .desatech.com 1 1 1250-01E 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 4 - Framing Clearances for Installation Against an Exterior Wall Figure 5 - Framing Clearances for Corner Installation C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 Wall Ref.
www .desatech.com 1 1 1250-01E 7 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N .
www .desatech.com 1 1 1250-01E 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 1 1250-01E 9 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 1 1250-01E 10 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 1 1250-01E 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Scr.
www .desatech.com 1 1 1250-01E 12 CORN ER AND AL TERNA TE INST ALL A TIO N Recommended Applications: • Corner ground oor installation • G ro un d o or in st a l la ti on w he re pi p e v en.
www .desatech.com 1 1 1250-01E 13 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 1 1250-01E 14 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 1 1250-01E 15 5. Pla ce the ash in g o ver t he pi pe sec tio n( s) extendin g through the roof. Secure the base of the ashing to the roof and framing with roof - ing nails. Be sure roong materi al overlap s the top edge of the ashing as shown in Figure 19, page 14.
www .desatech.com 1 1 1250-01E 16 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 1 1250-01E 17 AND COMPONENTS .
www .desatech.com 1 1 1250-01E 18 FIREPLACE INST ALLA TION Use proper gas type for replace unit you are installing.
www .desatech.com 1 1 1250-01E 19 FIREPLACE INST ALLA TION Continued Figure 27 - Location of Wiring Diagram Decal (Model May V ary from Illustration) Wiring Diagram Decal 12" in Front of Burner 9. Check to make sure power cord is completely clear of blower wheel and there are no other foreign objects in blower wheel.
www .desatech.com 1 1 1250-01E 20 1 1. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom ap - proxima tely 12" in front of blower (see Figure 27, page 19).
www .desatech.com 1 1 1250-01E 21 FIREPLACE INST ALLA TION Continued Figure 31 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 1 1250-01E 22 PRESSURE TESTING GAS SUPPL Y PIPING SYSTEM T est Pressures In Excess Of 1/2 PSIG 1. Dis conne ct rep lac e and i ts indiv idual equ ip - ment shutoff valve from gas supply piping sy st em .
www .desatech.com 1 1 1250-01E 23 INST ALLING OPTIONAL W ALL MOUNT SWITCH - GWMS2 1. Connect one terminal of 25 ft. wire for wall switch to TPTH terminal on the valve. Con - nect remaining wire terminal to the TH termi - nal on the valve. Make sure wire terminals are in positions on unit as pictured in Figure 36.
www .desatech.com 1 1 1250-01E 24 REMOVING/REPLACING GLASS DOOR .
www .desatech.com 1 1 1250-01E 25 .
www .desatech.com 1 1 1250-01E 26 6. Place log #6 (left log) onto two pins on left side of back and front log. See Figure 48. 7. Pla ce lava rock alon g sid es and front of rebox bottom in areas that are visible only . It is not necessary to use all of lava rock provided.
www .desatech.com 1 1 1250-01E 27 4. Push in gas control knob slightly and turn clockwise to OFF . 5. W ait ve (5) minutes to clear out any gas.
www .desatech.com 1 1 1250-01E 28 OPERA TING FIREPLACE Continued MANUAL LIGHTING PROCEDURE 1. Rem ove gla ss doo r (se e Remo vin g/R epl aci ng Glass Door ,page24.) 2. Follow steps 1 through 7 under Lighting Instructions, page27 .
www .desatech.com 1 1 1250-01E 29 4. Press the POWER and LOCK buttons togethertoturnoffther eplace Note: Do not leave the hand-held remote in the AUT O mode close to the replace.
www .desatech.com 1 1 1250-01E 30 INSPECTING B URNERS Check pilot ame pattern and burner ame pat - terns often. The pilot assembly is factory preset for the proper ame. Alt erations may have occurred during ship - ping and handling.
www .desatech.com 1 1 1250-01E 31 - .
www .desatech.com 1 1 1250-01E 32 TROUBLESHOO TING .
www .desatech.com 1 1 1250-01E 33 Pilot lights but ame goes out when control knob is released Burner does not light after pilot is lit Delayed ignition burner Burner backring during com - bustion Slight smoke or odor during initi al operation 1.
www .desatech.com 1 1 1250-01E 34 Heater produces a whistling noise when burner is lit Glass soots Fire plac e produc es a cl icki ng/t ick - ing noise just after burners are lit or shut off Remote does not function Fireplace shuts off in use 1.
www .desatech.com 1 1 1250-01E 35 TROUBLESHOO TING Continued .
www .desatech.com 1 1 1250-01E 36 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 1 1250-01E 37 - Rolled Louver , Black - Filligre.
www .desatech.com 1 1 1250-01E 38 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1250-01E 39 P ARTS LIST .
www .desatech.com 1 1 1250-01E 40 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1250-01E 41 DESCRIPTION 1 1 1 102 Screw #8-32 x 3/8 PPH Zinc 2 2 1 1 105 Screw #10 x 1/2 Zinc 9 3 1 1 179 Screw #10.
www .desatech.com 1 1 1250-01E 42 NO TES _____________________________________________________ ______________________________________________________ __________________________________________________.
www .desatech.com 1 1 1250-01E 43 NO TES _____________________________________________________ ______________________________________________________ __________________________________________________.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1250-01 Rev . E 03/06 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
An important point after buying a device Desa (V)T36NA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa (V)T36NA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa (V)T36NA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa (V)T36NA you will learn all the available features of the product, as well as information on its operation. The information that you get Desa (V)T36NA will certainly help you make a decision on the purchase.
If you already are a holder of Desa (V)T36NA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa (V)T36NA.
However, one of the most important roles played by the user manual is to help in solving problems with Desa (V)T36NA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa (V)T36NA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center