SCv2080 Storage System Getting Started Guide

Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2015 - 03

Consider the following best practices before setting up your SCv2080 storage system.

A fully configured SCv2080 storage system weighs up to 130 kg (287 lb). An unpopulated storage system weighs 62 kg (137 lb). Use appropriate lifting methods when installing the storage system.

The operating temperature inside the drawers of a storage system can reach up to 60°C (140°F). Take care when opening drawers and removing disk carriers.
Disconnect all electrical supply connections to the storage system before proceeding.


Laser Radiation for Fibre Channel Storage Systems
The unit is certified in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements of IEC 60825-1:2007.
Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition.

Use the following worksheet to record the information that is needed to install the SCv2080 storage system.
Gather and record the following information about the Storage Center network and the administrator user.
Table 1. Storage Center Network
Management IPv4 address (Storage Center management address)
Left Controller IPv4 address (Controller 1 MGMT port)
Right Controller IPv4 address (Controller 2 MGMT port)
Subnet mask
Gateway IPv4 address
DNS server address
Secondary DNS server address
Table 2. Storage Center Administrator
Password for the default Storage Center “Admin” user
Email address of the default Storage Center “Admin” user
For a storage system with iSCSI front-end ports, gather and record network information for the iSCSI fault domains. This information is needed to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
See the Dell Storage Center SCv2080 Storage System Deployment Guide for information about setting up iSCSI fault domains.
Table 3. iSCSI Fault Domain 1
Target IPv4 address
Subnet mask
Gateway IPv4 address
Service Tag Domain name

IPv4 address for storage controller module 1: port 1
IPv4 address for storage controller module 2: port 1
(Four port I/O card only) IPv4 address for storage controller module 1: port 3
(Four port I/O card only) IPv4 address for storage controller module 2: port 3
Table 4. iSCSI Fault Domain 2
Target IPv4 address
Subnet mask
Gateway IPv4 address
IPv4 address for storage controller module 1: port 2
IPv4 address for storage controller module 2: port 2
(Four port I/O card only) IPv4 address for storage controller module 1: port 4
(Four port I/O card only) IPv4 address for storage controller module 2: port 4
The Network Time Protocol (NTP) and Simple Mail Transfer Protocol (SMTP) server information is optional. The proxy server information is also optional, but it may be required to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
Table 5. NTP, SMTP, and Proxy Servers
NTP server IPv4 address
SMTP server IPv4 address
Backup SMTP server IPv4 address
SMTP server login ID
SMTP server password
Proxy server IPv4 address
For a storage system with Fibre Channel front-end ports, record the physical and virtual WWNs of the Fibre Channel ports in Fault Domain 1 and Fault Domain 2. This information is displayed on the Review Front-End page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard. Use this information to configure zoning on each Fibre Channel switch.
See the Dell Storage Center SCv2080 Storage System Deployment Guide for information about setting up Fibre Channel zoning.

Table 6. Physical WWNs in Fault Domain 1
Physical WWN of storage controller 1: port 1
Physical WWN of storage controller 2: port 1
(Four port I/O card only) Physical WWN of storage controller 1: port 3
(Four port I/O card only) Physical WWN of storage controller 2: port 3
Table 7. Virtual WWNs in Fault Domain 1
Virtual WWN of storage controller 1: port 1
Virtual WWN of storage controller 2: port 1
(Four port I/O card only) Virtual WWN of storage controller 1: port 3
(Four port I/O card only) Virtual WWN of storage controller 2: port 3
Table 8. Physical WWNs in Fault Domain 2
Physical WWN of storage controller 1: port 2
Physical WWN of storage controller 2: port 2
(Four port I/O card only) Physical WWN of storage controller 1: port 4
(Four port I/O card only) Physical WWN of storage controller 2: port 4
Table 9. Virtual WWNs in Fault Domain 2
Virtual WWN of storage controller 1: port 2
Virtual WWN of storage controller 2: port 2
(Four port I/O card only) Virtual WWN of storage controller 1: port 4
(Four port I/O card only) Virtual WWN of storage controller 2: port 4
Your storage system is identified by a unique Service Tag number.
You can find the Service Tag number on the back of the storage system chassis. Dell uses this information to route support calls to the appropriate personnel.
Additional information you may need to install the storage system.

Before you begin installation, make sure that the site where you plan to install the storage system has 208 V power from an independent source or a rack power distribution unit with a UPS. (110 V power is not supported.)
In addition, verify that there is a 5U space in the lower 20U of the rack to install the storage system. If you plan to install the storage system above the lower 20U of a rack, a customer-provided mechanical lift must be used to avoid injury.
Always follow these safety precautions to avoid injury and damage to Storage Center equipment.
If equipment described in the document is used in a manner not specified by Dell, the protection provided by the equipment may be impaired. For your safety and protection, observe the rules described in the following sections.
Follow these safety precautions:
The storage system chassis MUST be mounted in a rack; the following safety requirements must be considered when doing so:
Unpack the storage system and identify the items in your shipment.
Installation Safety Precautions


Figure 1. SCv2080 Storage System Components
Install the SCv2080 storage system and other Storage Center system components in a rack.


Figure 2. Mount the SCv2080 Storage System Chassis
Hard drives are connected to the backplane of the drawers using Disk Drive in Carrier (DDIC) hard drive carriers. The minimum number of drives in an SCv2080 storage system is 28 (one full, front row in the top drawer and one full, front row in the bottom drawer).
a. Push and hold both drawer latches toward the center of the drawer. b. Pull the drawer all the way out until it stops.
a. Hold the DDIC vertically and slide it most of the way into the slot. b. Using both hands, apply downward pressure firmly and equally across the DDIC. c. While maintaining downward pressure on the DDIC, slide the top plate toward the back of the
drawer until it clicks in place.


Figure 3. Installing DDIC in Drawer
a. Locate the two lock-release buttons situated midway along the runners on each side of the drawer. b. Press the lock-release buttons inward and use your body to push the drawer toward the chassis
until the locks disengage. c. Place your hands on the front bezel and continue to push the drawer inward until the bezel is
flush with the chassis and the front drawer locks engage.

Front-end cabling refers to the connections between the storage system and host servers. Front‐end connections can be made using Fibre Channel, iSCSI, or SAS interfaces.
The storage system connects to switches or connects directly to a host server, depending on the type of front-end ports.
In addition, the MGMT port on each storage controller connects to an Ethernet switch on the management network. This connection to the management network allows configuration, administration, and management of the Storage Center.
For more information, see the Dell Storage Center SCv2080 Storage System Deployment Guide.
Cabling SAN-Attached Host Servers
An SCv2080 storage system with Fibre Channel or iSCSI front-end ports connects to host servers through Fibre Channel or Ethernet switches.
a. Connect a cable from storage controller 1: port 1 to switch 1. b. Connect a cable from storage controller 2: port 1 to switch 1. c. (Four port I/O card only) Connect a cable from storage controller 1: port 3 to switch 1. d. (Four port I/O card only) Connect a cable from storage controller 2: port 3 to switch 1.
a. Connect a cable from storage controller 1: port 2 to switch 2. b. Connect a cable from storage controller 2: port 2 to switch 2. c. (Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2. d. (Four-port I/O card only) Connect a cable from storage controller 2: port 4 to switch 2.


Figure 4. Storage System Connected to Switches and Host Servers
Cabling Direct-Attached Host Servers
An SCv2080 storage system with SAS front-end ports connects directly to host servers.
a. Connect a SAS cable from storage controller 1: port 1 to server 1. b. Connect a SAS cable from storage controller 2: port 1 to server 1.
a. Connect a SAS cable from storage controller 1: port 2 to server 2. b. Connect a SAS cable from storage controller 2: port 2 to server 2.
a. Connect a SAS cable from storage controller 1: port 3 to server 3. b. Connect a SAS cable from storage controller 2: port 3 to server 3.
a. Connect a SAS cable from storage controller 1: port 4 to server 4. b. Connect a SAS cable from storage controller 2: port 4 to server 4.


Figure 5. Storage System Connected Directly to Host Servers
Cabling the Ethernet Management Network
The Ethernet management (MGMT) interface of each storage controller must be connected to a management network.


Figure 6. Storage System Connected to a Management Network
An SCv2080 storage system may be installed with or without an expansion enclosure.
If you are installing an SCv2080 storage system with an expansion enclosure, you must connect the expansion enclosure to the back-end SAS ports on the storage system.
If you are installing an SCv2080 storage system without an expansion enclosure, you must interconnect back-end SAS ports on the storage system.
Interconnecting Two Storage Controllers
When an SCv2080 with two storage controllers is deployed without expansion enclosures, the storage controllers must be interconnected using SAS cables.


Figure 7. Interconnected Storage Controllers
Cabling an Expansion Enclosure to a Storage System
An SCv2080 storage system supports one SC180 expansion enclosure. Use SAS cables to connect an SC180 expansion enclosure to an SCv2080 storage system.


Figure 8. SC180 Expansion Enclosure Connected to an SCv2080 Storage System
Connect power cables to the storage system.


Figure 9. Power Cables
Turn on the storage system after racking and cabling all of the Storage Center components.
Turn on the Storage Center system components in the following order:

Figure 10. Location of the SCv2080 Storage System Power Switches

The Dell Storage Client configures, manages, and monitors an SCv2080 storage system.
The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM):
Importer: Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 ° Piso Col. Lomas Atlas 11950 México, D.F.
The technical specifications of the SCv2080 storage system are displayed in the following tables.
SAS hard drives Up to 84 3.5-inch SAS hot-swappable hard drives (6.0 Gbps)
Drives

Storage controllers Two hot-swappable storage controllers with the following IO options:
Configurations Storage Center supports up to 168 drives on a single redundant-path SAS chain
An SCv2080 storage system supports one SC180 expansion enclosure
Redundant Array of Independent Disks (RAID)
Controller Two hot-swappable storage controllers
Management RAID management using Dell Storage Client 2015 R1
Back-Panel Ports Connectors (per Storage Controller)
Fibre Channel, iSCSI, or SAS connectors
Connection to a Fiber Channel fabric, iSCSI network, or a direct connection to servers with SAS HBAs
Ethernet connectors MGMT: 10 Mbps, 100 Mbps, or 1 Gbps embedded Ethernet port used for Storage Center management
REPL: 10 Mbps, 100 Mbps, or 1 Gbps embedded iSCSI port used for replication to another Storage Center
SAS connectors 6 Gbps SAS connectors for SAS port redundancy and an additional expansion enclosure
USB Connector One USB 3.0 connector used for Storage Center updates

Disk Drive In Carrier (DDIC)
One single-color LED for drive fault status
6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS ports and two for the module status
AC power supply (per power supply)
Wattage 2.8 kW
Voltage 200–240 VAC (16 A)
Heat dissipation 191-147 W
Input frequency 50/60 Hz
Max input power 1791 VA
Input current 7.4 A@241 VAC
Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less
Available Hard Drive Power (per Slot)
Supported hard drive power consumption (continuous)
Up to 1.16 A at +5 V
Up to 1.6 A at +12 V
I/O Card Power (per Slot)
Maximum power consumed by I/O Card
11 W at +12 V
100 W at +12 V
LED Indicators · Power Supplies · Maximum available power

I/O Card Power (per Slot)
1 W at +5 V (standby)
Height 22.23 cm (8.75 inches)
Width 48.26 cm (19 inches)
Depth 96 cm (38 inches)
130 kg (287 lb)
Weight without drives 62 kg (137 lb)
For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets
Operating 5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per hour
Storage –40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C per hour
Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Storage 5% to 100% (noncondensing)
Operating 0.21 G at 5–500 Hz for 15 min
Storage 1.04 G at 2–200 Hz for 15 min
Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% in operational orientations only
Operating –30.5 to 3000 m (–100 to 10,000 ft)

Storage –300 to 12,192 m (–1000 to 40,000 ft)
Class G2 or lower as defined by ISA-S71.04-1985
Environmental · Airborne Contaminant Level