Dell Storage Center

SCv2080 Storage System Getting Started Guide

Regulatory ModelE11J Regulatory Type: E11J001
Page 2 of the Dell SCv2080 user manual — Notes, Cautions, and Warnings
Page 2 · click to enlarge
Page 2

Notes, Cautions, and Warnings

Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

Rev. A00

2015 - 03

Page 3 of the Dell SCv2080 user manual — Safety Warnings
Page 3 · click to enlarge
Page 3

Before You Begin

Consider the following best practices before setting up your SCv2080 storage system.

  • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system.
  • Complete the Worksheet to Record System Information in this guide before configuring the storage system.
  • Always configure redundant data paths to provide alternate paths to and from the host server should one of the data paths become disabled.
  • Before connecting any cables between the storage system and host server or expansion enclosure, physically label each port and connector.
  • Always follow proper power-up and power-down procedures when cycling power across the network. Verify that critical network components are on separate power circuits.

Safety Warnings

Dell SCv2080 — Safety Warnings diagram (page 3)
Fig. 1 · Safety Warnings

A fully configured SCv2080 storage system weighs up to 130 kg (287 lb). An unpopulated storage system weighs 62 kg (137 lb). Use appropriate lifting methods when installing the storage system.

Dell SCv2080 — Safety Warnings diagram (page 3)
Fig. 2 · Safety Warnings

The operating temperature inside the drawers of a storage system can reach up to 60°C (140°F). Take care when opening drawers and removing disk carriers.

Disconnect all electrical supply connections to the storage system before proceeding.

Dell SCv2080 — Safety Warnings diagram (page 3)
Fig. 3 · Safety Warnings
Page 4 of the Dell SCv2080 user manual — Before You Begin
Page 4 · click to enlarge
Page 4
  • The battery should only be replaced with a battery that is the same or equivalent as the factory installed battery.
  • Do not attempt to open or service the battery. Do not dispose of the battery in a fire or with household waste. Contact the local waste disposal agency for the location of the nearest battery deposit site.

Laser Radiation for Fibre Channel Storage Systems

The unit is certified in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements of IEC 60825-1:2007.

Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition.

Page 5 of the Dell SCv2080 user manual — iSCSI Fault Domain Information
Page 5 · click to enlarge
Page 5

Worksheet to Record System Information

Use the following worksheet to record the information that is needed to install the SCv2080 storage system.

Storage Center Information

Gather and record the following information about the Storage Center network and the administrator user.

Table 1. Storage Center Network

Management IPv4 address (Storage Center management address)

Left Controller IPv4 address (Controller 1 MGMT port)

Right Controller IPv4 address (Controller 2 MGMT port)

Subnet mask

Gateway IPv4 address

DNS server address

Secondary DNS server address

Table 2. Storage Center Administrator

Password for the default Storage Center “Admin” user

Email address of the default Storage Center “Admin” user

iSCSI Fault Domain Information

For a storage system with iSCSI front-end ports, gather and record network information for the iSCSI fault domains. This information is needed to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.

See the Dell Storage Center SCv2080 Storage System Deployment Guide for information about setting up iSCSI fault domains.

Table 3. iSCSI Fault Domain 1

Target IPv4 address

Subnet mask

Gateway IPv4 address

Service Tag Domain name

Page 6 of the Dell SCv2080 user manual — Fibre Channel Zoning Information
Page 6 · click to enlarge
Page 6

IPv4 address for storage controller module 1: port 1

IPv4 address for storage controller module 2: port 1

(Four port I/O card only) IPv4 address for storage controller module 1: port 3

(Four port I/O card only) IPv4 address for storage controller module 2: port 3

Table 4. iSCSI Fault Domain 2

Target IPv4 address

Subnet mask

Gateway IPv4 address

IPv4 address for storage controller module 1: port 2

IPv4 address for storage controller module 2: port 2

(Four port I/O card only) IPv4 address for storage controller module 1: port 4

(Four port I/O card only) IPv4 address for storage controller module 2: port 4

Additional Storage Center Information

The Network Time Protocol (NTP) and Simple Mail Transfer Protocol (SMTP) server information is optional. The proxy server information is also optional, but it may be required to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.

Table 5. NTP, SMTP, and Proxy Servers

NTP server IPv4 address

SMTP server IPv4 address

Backup SMTP server IPv4 address

SMTP server login ID

SMTP server password

Proxy server IPv4 address

Fibre Channel Zoning Information

For a storage system with Fibre Channel front-end ports, record the physical and virtual WWNs of the Fibre Channel ports in Fault Domain 1 and Fault Domain 2. This information is displayed on the Review Front-End page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard. Use this information to configure zoning on each Fibre Channel switch.

See the Dell Storage Center SCv2080 Storage System Deployment Guide for information about setting up Fibre Channel zoning.

Page 7 of the Dell SCv2080 user manual — Other Information You May Need
Page 7 · click to enlarge
Page 7

Table 6. Physical WWNs in Fault Domain 1

Physical WWN of storage controller 1: port 1

Physical WWN of storage controller 2: port 1

(Four port I/O card only) Physical WWN of storage controller 1: port 3

(Four port I/O card only) Physical WWN of storage controller 2: port 3

Table 7. Virtual WWNs in Fault Domain 1

Virtual WWN of storage controller 1: port 1

Virtual WWN of storage controller 2: port 1

(Four port I/O card only) Virtual WWN of storage controller 1: port 3

(Four port I/O card only) Virtual WWN of storage controller 2: port 3

Table 8. Physical WWNs in Fault Domain 2

Physical WWN of storage controller 1: port 2

Physical WWN of storage controller 2: port 2

(Four port I/O card only) Physical WWN of storage controller 1: port 4

(Four port I/O card only) Physical WWN of storage controller 2: port 4

Table 9. Virtual WWNs in Fault Domain 2

Virtual WWN of storage controller 1: port 2

Virtual WWN of storage controller 2: port 2

(Four port I/O card only) Virtual WWN of storage controller 1: port 4

(Four port I/O card only) Virtual WWN of storage controller 2: port 4

Locating Your Service Tag

Your storage system is identified by a unique Service Tag number.

You can find the Service Tag number on the back of the storage system chassis. Dell uses this information to route support calls to the appropriate personnel.

Other Information You May Need

Additional information you may need to install the storage system.

  • The Dell Storage Center SCv2080 Storage System Deployment Guide provides information about cabling Storage Center hardware components and configuring a new Storage Center using the Dell Storage Client.
Page 8 of the Dell SCv2080 user manual — Unpacking Storage Center Equipment
Page 8 · click to enlarge
Page 8
  • The Dell Storage Center Dell Storage Client Administrator’s Guide describes how to use the Dell Storage Client to manage a Storage Center.

Installation and Configuration

Before you begin installation, make sure that the site where you plan to install the storage system has 208 V power from an independent source or a rack power distribution unit with a UPS. (110 V power is not supported.)

In addition, verify that there is a 5U space in the lower 20U of the rack to install the storage system. If you plan to install the storage system above the lower 20U of a rack, a customer-provided mechanical lift must be used to avoid injury.

Safety Precautions

Always follow these safety precautions to avoid injury and damage to Storage Center equipment.

If equipment described in the document is used in a manner not specified by Dell, the protection provided by the equipment may be impaired. For your safety and protection, observe the rules described in the following sections.

Follow these safety precautions:

  • Dell recommends that only individuals with rack-mounting experience install an SCv2080 storage system in a rack.
  • You need at least two people to lift the storage system chassis from the shipping box and three people to install it in the rack. The empty chassis weighs approximately 62kg (137 lbs).
  • Make sure the storage system is fully grounded at all times to prevent damage from electrostatic discharge.
  • When handling the storage system hardware, you should use an electrostatic wrist guard (not included) or a similar form of protection.

The storage system chassis MUST be mounted in a rack; the following safety requirements must be considered when doing so:

  • The rack construction must be capable of supporting the total weight of the installed chassis and the design should incorporate stabilizing features suitable to prevent the rack tipping or being pushed over during installation or in normal use.
  • When loading a rack with chassis, fill from the bottom up; empty from the top down.
  • To avoid danger of the rack toppling over, do not slide more than one chassis out of the rack at a time.
  • The storage system must be operated with low-pressure rear exhaust installation [back pressure created by rack doors and obstacles not to exceed 5 Pascals (0.5 mm water gauge)].
  • The rack design should take into consideration the maximum operating ambient temperature for the unit, which is 35°C.

Unpacking Storage Center Equipment

Unpack the storage system and identify the items in your shipment.

Installation Safety Precautions

Page 9 of the Dell SCv2080 user manual — Installing the Storage System in a Rack
Page 9 · click to enlarge
Page 9
Dell SCv2080 — Installing the Storage System in a Rack diagram (page 9)
Fig. 4 · Installing the Storage System in a Rack

Figure 1. SCv2080 Storage System Components

1. Documentation 2. Hard Drives
3. Storage system 4. Rack rails

Installing the Storage System in a Rack

Install the SCv2080 storage system and other Storage Center system components in a rack.

1. Determine where to mount the storage system in the rack and mark the location at the front and rear of the rack.
2. Position the rails at the marked locations and extend the rails to fit the rack.
3. Slide the storage system chassis onto the rails.
Page 10 of the Dell SCv2080 user manual — Installing the Hard Drives
Page 10 · click to enlarge
Page 10
Dell SCv2080 — Installing the Hard Drives diagram (page 10)
Fig. 5 · Installing the Hard Drives

Figure 2. Mount the SCv2080 Storage System Chassis

4. Secure the storage system chassis to the rack using hold-down brackets.
5. If the Storage Center system includes an expansion enclosure, mount the expansion enclosure above the storage system. See the instructions included with the expansion enclosure for detailed steps.

Installing the Hard Drives

Hard drives are connected to the backplane of the drawers using Disk Drive in Carrier (DDIC) hard drive carriers. The minimum number of drives in an SCv2080 storage system is 28 (one full, front row in the top drawer and one full, front row in the bottom drawer).

1. Open the bottom drawer.

a. Push and hold both drawer latches toward the center of the drawer. b. Pull the drawer all the way out until it stops.

2. Insert each disk drive in carrier (DDIC) into the drawer, one at a time.

a. Hold the DDIC vertically and slide it most of the way into the slot. b. Using both hands, apply downward pressure firmly and equally across the DDIC. c. While maintaining downward pressure on the DDIC, slide the top plate toward the back of the

drawer until it clicks in place.

Page 11 of the Dell SCv2080 user manual — Installing the Hard Drives
Page 11 · click to enlarge
Page 11
Dell SCv2080 — Installing the Hard Drives diagram (page 11)
Fig. 6 · Installing the Hard Drives

Figure 3. Installing DDIC in Drawer

1. DDIC 2. Bottom drawer
3. Close the drawer after inserting the DDICs.

a. Locate the two lock-release buttons situated midway along the runners on each side of the drawer. b. Press the lock-release buttons inward and use your body to push the drawer toward the chassis

until the locks disengage. c. Place your hands on the front bezel and continue to push the drawer inward until the bezel is

flush with the chassis and the front drawer locks engage.

4. Repeat the previous steps for the top drawer.
Page 12 of the Dell SCv2080 user manual — Front-End Cabling
Page 12 · click to enlarge
Page 12

Front-End Cabling

Front-end cabling refers to the connections between the storage system and host servers. Front‐end connections can be made using Fibre Channel, iSCSI, or SAS interfaces.

The storage system connects to switches or connects directly to a host server, depending on the type of front-end ports.

  • A storage system with Fibre Channel front-end ports connects to one or more FC switches, which connect to one or more host servers.
  • A storage system with iSCSI front-end ports connects to one or more Ethernet switches, which connect to one or more host servers.
  • A storage system with a SAS front-end interface connects directly to one or more host servers.

In addition, the MGMT port on each storage controller connects to an Ethernet switch on the management network. This connection to the management network allows configuration, administration, and management of the Storage Center.

For more information, see the Dell Storage Center SCv2080 Storage System Deployment Guide.

Cabling SAN-Attached Host Servers

An SCv2080 storage system with Fibre Channel or iSCSI front-end ports connects to host servers through Fibre Channel or Ethernet switches.

1. Connect each host server to the switches.
2. Connect fault domain 1 to switch 1.

a. Connect a cable from storage controller 1: port 1 to switch 1. b. Connect a cable from storage controller 2: port 1 to switch 1. c. (Four port I/O card only) Connect a cable from storage controller 1: port 3 to switch 1. d. (Four port I/O card only) Connect a cable from storage controller 2: port 3 to switch 1.

3. Connect fault domain 2 to switch 2.

a. Connect a cable from storage controller 1: port 2 to switch 2. b. Connect a cable from storage controller 2: port 2 to switch 2. c. (Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2. d. (Four-port I/O card only) Connect a cable from storage controller 2: port 4 to switch 2.

Page 13 of the Dell SCv2080 user manual — Front-End Cabling
Page 13 · click to enlarge
Page 13
Dell SCv2080 — Front-End Cabling diagram (page 13)
Fig. 7 · Front-End Cabling

Figure 4. Storage System Connected to Switches and Host Servers

1. Server 1 2. Server 2
3. Switch 1 4. Switch 2
5. SCv2080 storage system 6. Storage controller 1
7. Storage controller 2

Cabling Direct-Attached Host Servers

An SCv2080 storage system with SAS front-end ports connects directly to host servers.

1. Connect fault domain 1 to host server 1.

a. Connect a SAS cable from storage controller 1: port 1 to server 1. b. Connect a SAS cable from storage controller 2: port 1 to server 1.

2. Connect fault domain 2 to host server 2.

a. Connect a SAS cable from storage controller 1: port 2 to server 2. b. Connect a SAS cable from storage controller 2: port 2 to server 2.

3. Connect fault domain 3 to host server 3.

a. Connect a SAS cable from storage controller 1: port 3 to server 3. b. Connect a SAS cable from storage controller 2: port 3 to server 3.

4. Connect fault domain 4 to host server 4.

a. Connect a SAS cable from storage controller 1: port 4 to server 4. b. Connect a SAS cable from storage controller 2: port 4 to server 4.

Page 14 of the Dell SCv2080 user manual — Front-End Cabling
Page 14 · click to enlarge
Page 14
Dell SCv2080 — Front-End Cabling diagram (page 14)
Fig. 8 · Front-End Cabling

Figure 5. Storage System Connected Directly to Host Servers

1. Server 1 2. Server 2
3. Server 3 4. Server 4
5. SCv2080 storage system 6. Storage controller 1
7. Storage controller 2

Cabling the Ethernet Management Network

The Ethernet management (MGMT) interface of each storage controller must be connected to a management network.

1. Connect an Ethernet cable from the MGMT port on storage controller 1 to the management network switch.
2. Connect an Ethernet cable from the MGMT port on storage controller 2 to the management network switch.
Page 15 of the Dell SCv2080 user manual — Back-End Cabling
Page 15 · click to enlarge
Page 15
Dell SCv2080 — Back-End Cabling diagram (page 15)
Fig. 9 · Back-End Cabling

Figure 6. Storage System Connected to a Management Network

1. Management network switch 2. SCv2080 storage system
3. Storage controller 1 4. Storage controller 2

Back-End Cabling

An SCv2080 storage system may be installed with or without an expansion enclosure.

If you are installing an SCv2080 storage system with an expansion enclosure, you must connect the expansion enclosure to the back-end SAS ports on the storage system.

If you are installing an SCv2080 storage system without an expansion enclosure, you must interconnect back-end SAS ports on the storage system.

Interconnecting Two Storage Controllers

When an SCv2080 with two storage controllers is deployed without expansion enclosures, the storage controllers must be interconnected using SAS cables.

1. Connect a SAS cable between storage controller 1: port A and storage controller 2: port B.
2. Connect a SAS cable between storage controller 1: port B and storage controller 2: port A.
Page 16 of the Dell SCv2080 user manual — Back-End Cabling
Page 16 · click to enlarge
Page 16
Dell SCv2080 — Back-End Cabling diagram (page 16)
Fig. 10 · Back-End Cabling

Figure 7. Interconnected Storage Controllers

1. SCv2080 storage system 2. Storage controller 1
3. Storage controller 2

Cabling an Expansion Enclosure to a Storage System

An SCv2080 storage system supports one SC180 expansion enclosure. Use SAS cables to connect an SC180 expansion enclosure to an SCv2080 storage system.

1. Connect a SAS cable from storage controller 1: port A to the expansion enclosure: left EMM, port C.
2. Connect a SAS cable from storage controller 2: port B to the expansion enclosure: left EMM, port B.
3. Connect a SAS cable from storage controller 2: port A to the expansion enclosure: right EMM, port C.
4. Connect a SAS cable from storage controller 1: port B to the expansion enclosure: right EMM, port B.
Page 17 of the Dell SCv2080 user manual — Connecting the Power Cables
Page 17 · click to enlarge
Page 17
Dell SCv2080 — Connecting the Power Cables diagram (page 17)
Fig. 11 · Connecting the Power Cables

Figure 8. SC180 Expansion Enclosure Connected to an SCv2080 Storage System

1. SC180 expansion enclosure 2. SCv2080 storage system
3. Storage controller 1 4. Storage controller 2

Connecting the Power Cables

Connect power cables to the storage system.

1. Make sure that the power switches on the storage system are in the OFF position before connecting the power cables.
2. Connect the power cables to the power supplies in the storage system chassis.
Page 18 of the Dell SCv2080 user manual — Turning on the Storage System
Page 18 · click to enlarge
Page 18
Dell SCv2080 — Turning on the Storage System diagram (page 18)
Fig. 12 · Turning on the Storage System

Figure 9. Power Cables

3. Secure each power cable to the storage system chassis using the strain relief fasteners.
4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).

Turning on the Storage System

Turn on the storage system after racking and cabling all of the Storage Center components.

Turn on the Storage Center system components in the following order:

1. Turn on the network switches (if installed).
2. Turn on the expansion enclosure (if installed).
3. Turn on the storage system by pressing both power switches at the same time.
Dell SCv2080 — Turning on the Storage System diagram (page 18)
Fig. 13 · Turning on the Storage System

Figure 10. Location of the SCv2080 Storage System Power Switches

Page 19 of the Dell SCv2080 user manual — Technical Specifications
Page 19 · click to enlarge
Page 19
4. Turn on the host servers that are connected to the storage system.

Installing and Using the Dell Storage Client

The Dell Storage Client configures, manages, and monitors an SCv2080 storage system.

1. Go to support.dell.com and download the Dell Enterprise Manager software.
2. Install the Enterprise Manager Client on a host server.
3. Start the software by double-clicking the Enterprise Manager Client shortcut. The Dell Storage Client welcome screen appears.
  • To discover and configure an uninitialized SCv2080 storage system, click the Discover and Configure Uninitialized SCv2000 Series Storage Centers link and follow the steps in the wizard.
  • To connect to an initialized SCv2080 storage system, click the Log in to a Storage Center or Data Collector link.
  • To set up the host server to access Storage Center and configure Best Practices for performing IO, click the Setup this host to access a Storage Center link and follow the steps in the wizard.

NOM Information (Mexico Only)

The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM):

Importer: Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 ° Piso Col. Lomas Atlas 11950 México, D.F.

Model numberE11J
Supply voltage200–240 VAC
Frequency50/60 Hz
Current consumption16 A

Technical Specifications

The technical specifications of the SCv2080 storage system are displayed in the following tables.

SAS hard drives Up to 84 3.5-inch SAS hot-swappable hard drives (6.0 Gbps)

Drives

Page 20 of the Dell SCv2080 user manual — Installing and Using the Dell Storage Client
Page 20 · click to enlarge
Page 20

Storage controllers Two hot-swappable storage controllers with the following IO options:

  • Two 16 Gbps Fibre Channel ports
  • Four 8 Gbps Fibre Channel ports
  • Two 10 Gbps iSCSI ports
  • Four 1 Gbps iSCSI ports
  • Four 12 Gbps SAS ports

Configurations Storage Center supports up to 168 drives on a single redundant-path SAS chain

An SCv2080 storage system supports one SC180 expansion enclosure

Redundant Array of Independent Disks (RAID)

Controller Two hot-swappable storage controllers

Management RAID management using Dell Storage Client 2015 R1

Back-Panel Ports Connectors (per Storage Controller)

Fibre Channel, iSCSI, or SAS connectors

Connection to a Fiber Channel fabric, iSCSI network, or a direct connection to servers with SAS HBAs

Ethernet connectors MGMT: 10 Mbps, 100 Mbps, or 1 Gbps embedded Ethernet port used for Storage Center management

REPL: 10 Mbps, 100 Mbps, or 1 Gbps embedded iSCSI port used for replication to another Storage Center

SAS connectors 6 Gbps SAS connectors for SAS port redundancy and an additional expansion enclosure

USB Connector One USB 3.0 connector used for Storage Center updates

  • Front panel
  • One two-digit LCD indicator for Unit ID, error code, and unit location identifier
  • One two-color LED indicator for power status
  • One single-color LED indicator for module fault status (enclosure as a whole)
  • One single-color LED indicator for logical fault status (drive, HBA, RAID controller, and so on)
  • One single-color LED indicator for drawer 1 fault status
Show 4 more labels / short text on this page
Storage Controllers · Storage Connectivity · Serial connector · LED Indicators
Page 21 of the Dell SCv2080 user manual — Installing and Using the Dell Storage Client
Page 21 · click to enlarge
Page 21
  • One single-color LED indicator for drawer 2 fault status
  • Drawer
  • One single-color LED indicator for sideplane card and power status
  • One single-color LED indicator for drawer fault status
  • One single-color LED indicator for logical fault status
  • One single-color LED indicator for cable fault status
  • Six single-color LED indicators for data transfer status

Disk Drive In Carrier (DDIC)

One single-color LED for drive fault status

6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS ports and two for the module status

  • Cooling module
  • One single-color LED indicator for module status
  • One single-color LED indicator for battery fault status (not currently used)
  • One single-color LED indicator for fan fault status
  • Power Supply Unit (PSU)
  • One single-color LED indicator for PSU fault status
  • One single-color LED indicator for AC power fault status
  • One single-color LED indicator for power status

AC power supply (per power supply)

Wattage 2.8 kW

Voltage 200–240 VAC (16 A)

Heat dissipation 191-147 W

Input frequency 50/60 Hz

Max input power 1791 VA

Input current 7.4 A@241 VAC

Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less

Available Hard Drive Power (per Slot)

Supported hard drive power consumption (continuous)

Up to 1.16 A at +5 V

Up to 1.6 A at +12 V

I/O Card Power (per Slot)

Maximum power consumed by I/O Card

11 W at +12 V

100 W at +12 V

LED Indicators · Power Supplies · Maximum available power

Page 22 of the Dell SCv2080 user manual — Installing and Using the Dell Storage Client
Page 22 · click to enlarge
Page 22

I/O Card Power (per Slot)

1 W at +5 V (standby)

Height 22.23 cm (8.75 inches)

Width 48.26 cm (19 inches)

Depth 96 cm (38 inches)

130 kg (287 lb)

Weight without drives 62 kg (137 lb)

For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets

Operating 5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per hour

Storage –40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C per hour

Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour

Storage 5% to 100% (noncondensing)

Operating 0.21 G at 5–500 Hz for 15 min

Storage 1.04 G at 2–200 Hz for 15 min

Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% in operational orientations only

  • Storage
  • Z-axis: 30 g 10 ms half sine
  • Xand Y-axes: 20 g 10 ms half sine

Operating –30.5 to 3000 m (–100 to 10,000 ft)

Show 9 more labels / short text on this page
Minimum available power · Physical · Weight (maximum configuration) · Environmental · Temperature · Relative humidity · Maximum vibration · Maximum shock · Altitude
Page 23 of the Dell SCv2080 user manual — Installing and Using the Dell Storage Client
Page 23 · click to enlarge
Page 23

Storage –300 to 12,192 m (–1000 to 40,000 ft)

Class G2 or lower as defined by ISA-S71.04-1985

Environmental · Airborne Contaminant Level

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dell SCv2080

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell SCv2080

Be the first to ask — other owners or our team will answer.

Original document

Dell SCv2080 manual PDF

23 pages·1.3 MB·Portable Media Storage·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…