Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2014 - 09



Front-panel features and indicators

Figure 1. Front-panel features and indicators


Figure 2. Front-bezel features and indicators


Figure 3. Hard disk drive indicators
Hard disk drive- status indicator pattern (RAID Only)
Blinks green two times per second Identify hard disk drive or preparing for removal
Off Hard disk drive ready for insertion or removal
NOTE: The hard disk drive status indicator remains off until all hard disk drives are initialized after system power is turned on. Hard disk drives are not ready for insertion or removal during this time. The Dell PowerEdge RAID controller PERC H830 and 12Gb SAS HBA may take up to a minute to discover and initialize all the hard disk drives.
Blinks green, amber, and off Hard disk drive predicted failure
Blinks amber four times per second Hard disk drive failed
Blinks green slowly Hard disk drive rebuilding
Steady green Hard disk drive online
Condition

Hard disk drive- status indicator pattern (RAID Only)
Blinks green for three seconds, amber for three seconds, and turns off in six seconds.

Figure 4. Back-panel features and indicators
Each EMM provides the following data path and enclosure management functions for your enclosure:
Condition · Rebuild aborted


Figure 5. Enclosure Management Module
If two EMMs are installed, a certain degree of failover is offered. Control and monitoring of the enclosure elements can be transferred from one EMM to another in the event of an EMM failure. A failover occurs whenever network communication is ended between an EMM and its peer.
In the event of a peer EMM failure, the surviving EMM activates the amber status LED of the failed EMM. The surviving EMM then takes over the responsibility of enclosure management, which includes monitoring and control of the enclosure LEDs, power supply units, and fans.
If critical internal temperatures are reached, the enclosure turns off automatically through either a thermal shutdown command issued by the EMM firmware or through a command from Dell OpenManage Server Administrator.


Figure 6. Power indicator codes


Recommended tools
You may need the following items to perform the procedures in this section:

Figure 7. Removing and installing the front bezel

Models AMT, E03J, and E04J are intended for installation only in restricted access locations as defined in cl 1.2.7.3 of IEC 60950-1:2005.
On the basis of your configuration, your enclosure either supports up to up to 12 3.5-inch SAS hard disk drives in internal drive bays. Hard disk drives are connected to a backplane using hard disk drive carriers and are configured as hot-swappable.
When you format a hard disk drive, allow enough time for the formatting to complete. High-capacity hard disk drives can take many hours to format.


Figure 8. Removing and installing a 3.5-inch hard disk drive blank
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If the hard disk drive has been online, the green activity or fault indicator flashes as the hard disk drive is turned off . When the drive indicators are off, the hard disk drive is ready for removal. See Hard disk drive indicator patterns.


Figure 9. Removing and installing a hard disk drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Remove the screws from the slide rails on the hard disk drive carrier and separate the hard disk drive from the carrier.


Figure 10. Removing and installing a hard drive into a 3.5-inch hard disk drive carrier
When aligned correctly, the back of the hard disk drive is flush with the back of the hard disk drive carrier.
An enclosure with redundant enclosure management contains two enclosure management modules (EMM). You can cable your enclosure either in a single port, redundant mode or in a multi-mode configuration. If only one EMM is installed in your enclosure, it must be installed in EMM 0. You must install the EMM blank in EMM 1.


Figure 11. Removing and installing an EMM blank
To install an EMM blank, align the blank with the EMM bay and insert the blank into the chassis until it clicks into place.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.


Figure 12. Removing and installing an EMM
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
For more information about EMM connections and cabling, see Dell Storage MD1400 and MD 1420 Enclosure Hardware Deployment Guide.

Your enclosure supports two hot-swappable power supply unit or cooling fan modules. While the enclosure can operate temporarily with one module, both the modules must be present for cooling the enclosure.

Figure 13. Removing and installing a power supply unit or cooling fan module


Figure 14. Securing the power cable
An MD Series storage array receives its power from two power supply modules. In a DC-powered MD Series storage array, the power supply module receives power from two 48 V DC PSUs. Each power supply module has two cooling fans.
The DC power supply module has LEDs that indicate power supply status. Under normal conditions, the power output and line input LEDs are lit at the same time.


Figure 15. Power indicator codes
Item LED Color State
– The power switch is off. – The power supply module is not connected to power. – There is a fault condition.
2 Power supply module fault
1 Power output


Figure 16. DC power supply module back panel features
1 Power supply release lever
Unlocks the power supply module for removal from the storage array.
2 Connector on the power supply module
Connects the power supply module to the DC power supply module.
3 Power supply On or Off switch
Controls the power supply module power output to the storage array.
4 Protective safety earth ground
Provides grounding for the power supply module. It must be connected to the building's protective safety earth ground.

Assembling and connecting the safety ground wire
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

Figure 17. Assembling and connecting the safety ground wire
Required Wires

Wiring the power cables
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
The DC power supply module must be hard-wired to a DC power source in your environment by a qualified electrician. To wire your DC power supply module to a DC power source:
As specified in the following table:

Figure 18. Dc power cable d-shell connector and terminals
Pin Description Wire Color Wire Size
1 48V DC Safety Ground (F or G) Green or Yellow 10 AWG
2 –48V DC Return (+) Blue 10 AWG
3 –48V DC (–) Black 10 AWG
Connecting the power cable to the power supply module


Figure 19. Connecting the dc power cables
Removing a DC power supply
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself .All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.


Figure 20. Removing and installing a dc power supply module
Installing a DC Power Supply Module
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

Power Supply Module Failures
You can identify a power supply module failure by any or all of the following:
Troubleshooting a DC power supply
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
If the line input LED is not lit, check the power cable and power source to which the power supply is connected.
For more information, see Removing a DC power supply and Installing a DC power supply.
If the problem is not resolved, see Getting Help.

AC Power Supply (per power supply)
2047 BTU/hr (redundant, 600 W power supply)
100–240 V AC, autoranging, 50/60 Hz
DC Power Supply (per power supply)
2388 BTU/hr (redundant, 700 W power supply)
Voltage –(48–60) V DC
Maximum operation ambient temperature 35° C
For information about supported expanded operating temperature range and configurations, see dell.com/support/manuals


Figure 21. Removing and installing the control panel
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.


Figure 22. Removing and installing the EMM or power supply cage


Figure 23. Removing and installing the backplane

Safety first—for you and your enclosure
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If your system stops functioning during startup, check if:
For information about troubleshooting loss of communication, see Troubleshooting Enclosure Management Modules.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

– Connect another device to the power source to verify if it is working.
– Connect the cable to a different power source.
– Replace the power cable.
If the problem is not resolved, see Getting Help.
CAUTION: Power supply unit or cooling fan modules are hot-swappable. The enclosure can operate on a single power supply; however both modules must be installed to ensure proper cooling. A single power supply unit or cooling fan module can be removed from a powered- on enclosure for a maximum period of five minutes. Beyond that time, the enclosure may automatically shut down to prevent damage.
If the problem is not resolved, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Ensure that none of the following conditions exist:
If the problem is not resolved, see Getting Help.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
– Turn off the server.
– Remove the EMM and verify that the pins on backplane and EMM are not bent. See Removing an EMM.
– Reinstall the EMM and wait for 30 seconds. See Installing an EMM.
– Turn on the server.
– Check the EMM status LED.
– Turn off the server.
– Reseat the cables on the storage enclosure and the server.
– Restart the storage enclosure and wait until enclosure is fully booted.
– Turn on the server.
– Check the link status LED. If the link status LED is not green, proceed to the next step.
If the problem is not resolved, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If the problem is not resolved, go to task 5.

If the problem is not resolved, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If the enclosure does not start properly, see Getting Help.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

If the test fails, see Getting Help.

Contacting Dell
To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system service tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.