Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2015 - 03



The Dell Storage MD1280 Service Guide provides information about enclosure service and maintenance.
A Dell Storage MD1280 enclosure holds the physical disk drive storage. The interface between the controller I/O cards and the enclosure is referred to as back‐end connectivity.
The Dell Storage MD1280 is a 5U SAS enclosure and supports up to 84 hard drives in 3.5-inch carriers, installed in a two‐drawer, three‐row, and 14‐column configuration. The Dell Storage MD1280 enclosure ships with two redundant power supply units (PSUs), five redundant cooling fan modules, and two redundant 6 Gbps SAS I/O modules.
The Storage Enclosure Management software enables you to manage, update, and monitor MD1280. For more information, see Dell Storage MD1280 Administrator's Guide available at www.dell.com/support
The Dell Storage MD1280 enclosure uses LED indicators to indicate an issue with the enclosure.
The front panel displays the enclosure and power status.


Figure 1. Front-panel features and indicators
Table 1. Front-panel features and indicators


The back panel displays PSU, connectivity, and fault indicators.


Figure 2. Back-panel features and indicators
Table 2. Back-panel features and indicators
1 Optional cable retention positions (4)
2 I/O enclosure management modules (2)
3 Fan modules (5)
NOTE: Each fan module includes two fans. The Storage Enclosure Management Software lists 10 fans 0–9. The physical enclosure enumerates the enclosures 1–5. Therefore, in the Storage Enclosure Management Software, fans 0–1 are related to fan module 0, fans 2–3 are related to fan module 1, fans 4–5 related to fan module 4, fans 6–7 are related to fan module 5, and fans 8–9 are related to fan module 5.
5 Optional cable retention positions (2)
6 Power switches (2)
Dell Storage MD1280 enclosure includes two I/O Enclosure Management Modules (EMMs).
Item Control/Feature · 4 PSUs (2)


Figure 3. I/O EMM features and indicators
Table 3. I/O EMM features and indicators
Dell Storage MD1280 enclosure includes five fan modules in five interface slots.


Figure 4. Fan module features and indicators
Table 4. Fan module features and indicators
Dell Storage MD1280 enclosure includes two PSUs in two interface slots.

Figure 5. PSU features and indicators

Table 5. PSU features and indicators
If all three LEDs are off then there is no AC power supplied to either PSU.
The Disk Drive In Carrier (DDIC) includes one status indicator.

Figure 6. DDIC indicator

Table 6. DDIC indicator

This section describes the tasks to replace field replaceable units (FRUs) inside the Dell Storage MD1280 enclosure. Here, it is assumed that the user has already received the appropriate replacement device and is ready to install the device in the enclosure.
To avoid injury and damage to the enclosure, always follow these safety precautions.
To avoid injury and damage to the enclosure, always follow electrical safety precautions.
To avoid injury and damage to an enclosure, always follow general safety precautions.

To avoid injury and damage to the enclosure, always follow electrostatic discharge (ESD) precautions.
ESD is generated by two objects with different electrical charges coming into contact with each other. The resulting electrical discharge can damage electronic components and PCBs.
If the FRU is not hot‐swappable, the EMMs and enclosure must be turned off.
About this task To turn off the EMMs and enclosure, complete the following tasks:
Steps 1. Before turning off the EMMs and enclosure, identify the failed devices.
The Dell Storage MD1280 enclosure supports two 2.8kW AC hot‐swappable PSUs. If one PSU stops functioning, the second PSU continues to supply power to the enclosure.
To identify a non-functioning PSU, use the secli component of the Storage Enclosure Management Software or visually verify which PSU is not functioning. For more information on using the secli to identify failed devices, see the Dell Storage MD1280 Administrator's Guide.
About this task To replace failed PSUs, complete the following tasks:

Steps 1. Turn off the PSU switch.

Figure 7. Removing a PSU


Figure 8. Securing the power cord
The Dell Storage MD1280 enclosure supports five fan modules. If one fan module fails, the remaining modules continue to cool the enclosure.
To identify the failed fan module, use the secli component of the Storage Enclosure Management Software or visually verify which fan module is not functioning properly. For more information on using the secli to identify failed devices, see the Dell Storage MD1280 Administrator's Guide.
About this task To replace a failed fan module, complete the following tasks:
Steps 1. Press the red release tab and pull the fan module out of the chassis by using the handle.


Figure 9. Removing a fan module
The Dell Storage MD1280 enclosure supports hot‐swappable hard drives and supports up to 84 hard drives in 3.5-inch carriers, installed in a two‐drawer, three‐row, 14‐column configuration. Hard drives are connected to a backplane by using Disk Drive in Carrier (DDIC) hard drive carriers.
Hard drives are numbered in the secli, starting with 0. Dell Storage MD1280 DDIC slots are numbered 1– 42 in drive drawer 0, from front to back and left to right, and 43–84 in drive drawer 1.


Figure 10. Numbering the hard drive
To identify the failed hard drive, use the secli component of the Storage Enclosure Management Software or visually verify the failed hard drive. For more information on using the secli to identify failed devices, see the Dell Storage MD1280 Administrator's Guide.
About this task Hard drives can be replaced one at a time without turning off the enclosure. To replace failed hard drives, complete the following tasks:
Steps 1. Find the Dell Storage MD1280 enclosure and the drive drawer containing the failed hard drive. The fault drive drawer LED glows.


Figure 11. Opening a DDIC


Figure 12. Removing a DDIC
CAUTION: To maintain proper airflow, the drive drawers must be populated with hard drives in whole rows at a time (there are three rows of 14 hard drives per drawer). The minimum number of hard drives in an enclosure is 14 (one full, front row in the top drive drawer), the number of populated rows between drive drawers must not differ by more than one. The rows should be populated from the front to the rear of the enclosure.


Figure 13. Closing a drive drawer
a. Pull and hold both drive drawer releases and push the drive drawer inside slightly. b. Release and push the drive drawer until it clicks into a place.
The Dell Storage MD1280 enclosure supports redundant hot‐swappable I/O Enclosure Management Modules (EMMs).
EMMs provide the following data path and enclosure management functions for the enclosure:

To identify the failed EMM, use the secli component of the Storage Enclosure Management Software or visually verify the EMM that is not functioning. For more information on using the secli to identify failed devices, see the Dell Storage MD1280 Administrator's Guide.
About this task EMMs can be replaced one at a time without turning off the enclosure. To replace failed EMMs, complete the following tasks:
Steps 1. Remove all cables from the EMM. Ensure all the cables are labeled.

Figure 14. Replacing an EMM

Replacing the chassis is required when non-FRU devices must be replaced. Replacing a chassis requires a scheduled maintenance window when the system is unavailable. The replacement chassis comes without any FRUs, and therefore all cards and DDICs must be transferred to the new chassis.
To replace a chassis, complete the following tasks:
a. Remove the fixing screws from the rear of the enclosure. b. Remove the HDBs from the rear of the rack.
Rack rails are used to install the Dell Storage MD1280 enclosure into a rack.
About this task To replace rack rails, complete the following tasks:
a. Remove the fixing screws from the rear of the enclosure.
About this task · Steps · Steps

b. Remove the HDBs from the rear of the rack.
After replacing an FRU in Dell Storage MD1280, turn on the EMMs and enclosure, if they were turned off.
About this task If the servers and enclosure are turned off, turn on the servers by doing the following:
Steps 1. Insert the power cords.

This section contains basic troubleshooting tasks for components inside the Dell Storage MD1280 enclosure.
About this task To troubleshoot fan modules, complete the following tasks:
Steps 1. Determine the status of the fan module LEDs.
If the fan fault LED glows, it implies that the fan module has failed.
About this task To troubleshoot PSUs, complete the following tasks:
Steps 1. Determine the status of the PSU LEDs.
a. If the PSU fault LED glows, it implies that the PSU has failed. b. If the Power OK LED is not glowing, check the power cord and power source into which the PSU
is inserted:
supplying the power.
About this task To troubleshoot DDICs, complete the following tasks:

Steps 1. Determine the status of DDIC LED.
a. If the DDIC fault LED glows, it implies that the hard drive has failed.
a. Remove the DDIC. b. Check the DDIC and the backplane to ensure that the connectors are not damaged. c. Reinstall the DDIC. Ensure the DDIC contacts the backplane.
About this task To troubleshoot I/O EMMs, complete the following tasks:
Steps 1. Check the pins and reseat the EMM.
a. Remove the EMM. b. Verify that the pins on the backplane and the EMM are not bent. If any pins are bent, do not
attempt to correct them; instead, contact Dell technical support services for further instructions. c. Reinstall the EMM.
a. Reseat the cables on the enclosure and the controller. b. Recheck the link status LEDs. If the link status LEDs are not glowing green, replace the cables.

The technical specifications of the MD1280 are displayed in the following tables.
SAS hard drives Up to 84 SAS hot-swappable hard drives (6.0 Gbps or 12.0 Gbps) and SSDs
Enclosure Management Modules (EMM)
EMMs Two hot-swappable I/O EMM modules
Configurations Various server-attached configurations as specified by your solution provider.
SAS connectors • Asymmetric SAS Cabling for connection to the host and for expansion to an additional enclosure
Front panel • One two-digit LCD indicator for Unit ID, error code, and unit location identifier
Disk Drive In Carrier (DDIC) One single-color LED for hard drive fault status

6 Gbps SAS I/O module 14 one-color LED status indicators, four each for the three SAS ports, and two for the module status
Power Supply Units (per PSU)
Watt 2.8 kW
Voltage 200–240 VAC (8.6 A–4.3 A)
Heat dissipation 191–147 W
Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A for each PSU for 10 ms or less.
Available Hard Drive Power (Per Slot)
Supported hard drive power consumption (continuous)
Up to 1.16 A at +5 V, Up to 1.6 A at +12 V
I/O Card Power (Per Slot)
Maximum power consumed by I/O Card 11 W at +12 V
Maximum available power 100 W at +12 V
Maximum available power 1 W at +5 V (standby)
Height 22.23 cm (8.75 inches)
Width 48.26 cm (19 inches)
LED Indicators · Physical

Depth (front mounting bracket to rear surface) 91.5 cm (36 inches)
Depth (front surface to rear surface) 96 cm (38 inches)
Full Weight (maximum configuration) 130.7 kg (287.5 lb)
Shipping Weight (without hard drives) 62 kg (137 lb)
Physical

Operating 5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per hour
Storage –40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C an hour
Operating 20 percent to 80 percent (noncondensing) with a maximum humidity gradation of 10 percent an hour
Storage 5 percent to 100 percent (noncondensing)
Operating 0.21 g at 5–500 Hz for 15 min
Storage 1.04 g at 2–200 Hz for 15 min
Operating Half-sine shock 5 g +/- 5 percent with a pulse duration of 10 ms +/- 10 percent in operational orientations only
Operating –30.5 to 3000 m (–100 to 10,000 ft)
Storage –300 m to 12,192 m (–1000 ft to 40,000 ft)
Class G2 or lower as defined by ISA-S71.04-1985



Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.