Read and understand all safety information
before installing and using this product.

Copyright This manual is © 3M 2002. All rights reserved.
Reproduction of the contents of this copyrighted manual in whole or in part, by any means, electronic or mechanical, for any purpose, without written permission of 3M Touch Systems, a subsidiary of 3M, is prohibited.
Notice Given the variety of factors that can affect the use and performance of a 3M Touch Systems Product, including that solid state equipment has operation characteristics different from electromechanical equipment, some of which factors are uniquely within User’s knowledge and control, it is essential that User evaluate the 3M Touch Systems product to determine whether it is suitable for User’s particular purpose and suitable for User’s method of application. 3M Touch Systems’ statements, engineering/technical information, and recommendations are provided for User’s convenience, but their accuracy or completeness is not warranted. 3M Touch Systems products are not specifically designed for use in medical devices as defined by United States federal law. 3M Touch Systems products should not be used in such applications without 3M Touch Systems’ express written consent. User should contact its sales representative if User’s opportunity involves a medical device application.
Specifications are subject to change without notice. 3M Touch Systems’ Products are warranted to meet their published specifications from the date of shipment and for the period stated in the specification. 3M Touch Systems makes no additional warranties, express or implied, including but not limited to any implied warranties of merchantability or fitness for a particular purpose. User is responsible for determining whether the 3M Touch Systems Products are fit for User’s particular purpose and suitable for its method of production, including intellectual property liability for User's application. If a Product is proven not to have met 3M Touch Systems’ warranty, then 3M Touch Systems’ sole obligation and User’s and Purchaser’s exclusive remedy, will be, at 3M Touch Systems’ option, to repair or replace that Product quantity or to refund its purchase price. 3M Touch Systems has no obligation under 3M Touch Systems’ warranty for any Product that has been modified or damaged through misuse, accident, neglect, or subsequent manufacturing operations or assemblies by anyone other than 3M Touch Systems. 3M Touch Systems shall not be liable in any action against it in any way related to the Products for any loss or damages, whether non-specified direct, indirect, special, incidental or consequential (including downtime, loss of profits or goodwill) regardless of the legal theory asserted. (11/01)
Trademarks 3M Dynapro, MicroTouch, TouchSurround, and Near Field Imaging are trademarks of 3M. Windows and Microsoft are trademarks of Microsoft Corporation.

The 3M DynaproTM ET 350 monitor (specifically, monitor models ET 350R, ET 350L2, and ET 350L3) is intended to provide touch screen functions when connected to a host computer in an industrial setting. The ET 350 monitor is not intended for use in hazardous locations.
To reduce the risk of fire or explosion which could result in serious personal injury or death:
Do not install or use this product in a hazardous location.
When using a flammable or combustible cleaning solution or fluid on or near
the ET 350 monitor, refer to the cleaner manufacturer’s material safety data sheet and follow all instructions and recommendations.
To reduce the risk of fire or electric shock which could result in serious personal injury or death:
Follow all product and accessory installation instructions.
Any servicing or other procedures not described in this manual are to be
performed only by 3M Touch Systems service personnel.
For the ET 350R monitor in a Pollution Degree 3 environment, install the unit
in an enclosure that is sealed to a NEMA 4X/IP66 standard.
Install the ET 350 monitor close to the power source so the unit can be easily
and quickly disconnected. For permanently connected equipment, a readily accessible disconnect device must be incorporated in the fixed wiring.
Engineer the installation of the ET 350 monitor to take into account the
operating environment (e.g., thermal, shock/vibration factors).
Provide a clean, reliable grounding.
When connecting power with fixed field wiring, the power cable must be double
insulated. A clear, flexible insulator (supplied) must cover the portion of the cable that is not double insulated when connecting to a terminal strip connector.
Wiring installation should be done by a licensed journeyman electrician and
must comply with federal and local electrical codes.
When replacing a fuse or other part, use a part of the type and rating specified
by 3M Touch Systems.
Properly install the ET 350R monitor so that it is environmentally sealed to
NEMA 4X/IP66 standard.
Properly install the ET 350R monitor with a NEMA 4X/IP66 gasket that is
undamaged and effective.
Do not use an ET 350 monitor that is not rated to NEMA 4X/IP66 in
environments that require a NEMA 4X/IP66 seal.
Do not damage any ET 350 monitor gaskets.

To reduce the risk of electric shock which could result in serious personal injury or death:
Do not open the power supply in the ET 350 monitor. It contains hazardous
voltages. The power supply has no user-serviceable parts or adjustments inside.
Make sure that the ground potential difference between the ET 350 monitor
and the host computer is less than 2V.
Provide adequate strain relief for all communications and power cables.
Before removing the ET 350 monitor from its mounting, disconnect power to
the unit.
To reduce the risk of electric shock or mechanical impact which could result in serious personal injury or death:
Apply a “safe touch” setting, especially if the monitor is running an application
or is in a setting where safety is a concern.
Do not use a non-Windows operating system screen saver that may affect the
“safe touch” setting and could in turn cause connected peripheral equipment to start or stop inadvertently.
Set the safe touch setting correctly, with the number of minutes entered for the
Windows operating system’s energy saver being at least one minute greater than the time entered for the Windows operating system screen saver.
If your ET unit has a display power management system (DPMS) that is
configurable from the display’s on-screen utility menu, do not turn off the DPMS.
To reduce the risk of minor or moderate injury from contact with cleaning solutions or fluids, through means such as ingestion and skin contact:
Refer to the cleaner manufacturer’s material safety data sheet and follow all
instructions and recommendations.
To reduce the risk of electric shock or fire which may result in minor or moderate injury or cause property damage:
If the ET 350 monitor will be used in corrosive environments, it is the
responsibility of the user to test and evaluate the monitor in those environments. The monitor, as shipped, has not been evaluated for use in corrosive environments and using it in such environments, without evaluation and testing, may lead to unsafe conditions.
To reduce the risk of muscle strain which may result in minor or moderate injury or cause property damage:
Avoid using the ET 350 monitor for long periods of time without breaks.
To reduce the risk of eye strain which may result in minor or moderate injury or cause property damage:
Use the monitor where there is neither too much ambient light nor glare on the
screen.
To reduce the risk of environmental contamination which may result in minor or moderate injury or cause property damage:
Dispose of the monitor according to applicable governmental regulations.

To reduce the risks associated with electric shock and/or burn- related injury that could result in death or serious injury and/or property damage:
Do not open the power supply in the ET unit. It contains hazardous voltage/
hazardous energy. The power supply has no user-serviceable parts or adjustments inside.
Avoid contact with connectors on power terminal strip unless the power has
been disconnected.
Avoid exposed electrical contacts inside the ET unit. To reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage:
If the ET unit is mounted using a NEMA 4X panel gasket, install the unit in a
Listed (UL) enclosure. To reduce the risks associated with mechanical function which, if not avoided, could result in property damage:
Do not operate the ET unit in conditions outside of the operational
specifications. To reduce the risks associated with fire and explosion which, if not avoided, could result in death or serious injury and/or property damage:
Do not use flammable or combustible cleaners on or near the monitor.
The following safety symbols are used on the exterior and interior of the ET 350 monitor:
Product safety information






About the User’s Installation Guide
Topics This manual is written for system integrators and day-to-day users of the 3M DynaproTM ET 350 monitor. The manual covers the following topics:
Installing communication and power cables
Installing the touch screen software
Adjusting display settings
Mounting the monitor
Maintaining and cleaning the monitor
Customizing and replacing a TouchSurroundTM graphic underlay
For a list of all warnings and cautions that appear in this manual, see “Product safety information”, starting on page i.
For information on the safety symbols used on the interior and exterior of the monitor, see “Explanation of safety labels” on page iii.
Related documents Mounting instructions for ET 350R and ET 350L3 monitors If you ordered either the ET350R monitor or the ET 350L3 monitor, one of these installation instruction documents will ship with this manual and your monitor (and are also available for download from the 3M Touch Systems web site: www.3Mtouch.com):
Installing the NEMA 4X Panel Gasket (comes with ET 350R monitor)
Installing the NEMA 4X Hatch (comes with ET 350L3 monitor)
For more information on ET 350 monitor models, see “Distinctive features of each model” on page 8.
Instructions for optional mounting kits For information on optional mounting kits and the installation instructions that accompany those kits, see “Optional mounting kits” on page 28.

Software guides The ET 350 monitor User’s Installation Guide explains how to install touch screen software that will run with operating systems supported by the ET 350 (see Chapter 2).
For information on how to customize the software, refer to one of the following manuals. Both of these software guides may be downloaded from the 3M Touch Systems web site (www.3Mtouch.com).
For Windows XP Professional and Windows 2000 Professional operating systems, refer to: MicroTouch NFI Software Guide for Windows XP and Windows 2000.
ForWindows NT 4.0 and Windows 9X operating systems, refer to: Configuration Utilities User’s Guide.
README files On the floppy disks that came with your ET 350 monitor, there are README files with driver installation instructions and other driver information.
This term Refers to
ACPI Advanced Configuration and Power Interface. A power management feature that is configurable in Windows operating systems.
Bezel* The front rim of the unit that contains the touch screen and the TouchSurround.
Display area* The part of the touch screen that is positioned over the display of the monitor. Touches in the display area emulate the movements and actions of a mouse.
DPMS Display power management system. Some ET units allow this energy saving setting to be changed. For ET 35X monitor models without a heater, the DPMS should not be turned off. For DPMS instructions for ET 35X monitor models with a heater, refer to instructions that ship with models with heaters.
Graphic underlay (also called TouchSurround underlay)
A graphic that illustrates the TouchSurround and fits behind the touch screen. 3M Dynapro industrial products may be ordered with standard or custom underlays. Buttons and controls for the standard underlays are pre-defined; you must define buttons and controls for custom underlays.
KVM extender An optional feature of the ET 350 monitor that allows the monitor to be located as much as 1000 feet (300 meters) from the host computer.
A touch screen that uses a proprietary imaging technique to generate a precise profile of a touch from voltage changes in the electrostatic field close to the point of contact.
MicroTouchTM Near Field
ImagingTM (NFI) touch screen
Touch screen The front surface of the ET 350 monitor, comprising the display area and the TouchSurround.
TouchSurround* The area on the front of the touch screen, not including the display area. With the TouchSurround, part of the touch screen can be used to define keys (such as keyboard keys).
*For illustration identifying this item, see Figure 1, page 6

Product support Registration Register your 3M Dynapro ET 350 monitor by mailing the postage-paid Product Registration Card. It detaches from the Warranty Card that came with your unit. The Product Registration Card may also be faxed to 3M Touch Systems (604-521-4629).
Returning products All returned 3M Dynapro industrial products must be accompanied by a Service Return Authorization (SRA) number. For details, contact 3M Touch Systems customer service.
Contacting 3M Touch Systems For general information, service, and technical support for 3M Dynapro industrial products, use the contact information below:
Area Type of service Contact information
Tel 800-667-0374 (toll free)*
E-mail etsales@mmm.com
Web site www.3Mtouch.com
Tel 800-667-0374 (toll free)*
E-mail 3MTScustomerservice@mmm.com
Tel 800-667-0374 (toll free)*
E-mail 3Mdynaprotechsupport@mmm.com
Outside USA and Canada
E-mail etsales@mmm.com
E-mail 3MTScustomerservice@mmm.com
E-mail 3Mdynaprotechsupport@mmm.com
*Call between 7:30 a.m. and 5:00 p.m., Pacific Time



Introducing the ET 350 monitor
About the chapter This chapter provides the following information:
Basic and model-specific packing lists for the ET 350 monitor
Standard features of the ET 350 monitor
Distinctive features of each ET 350 monitor model
Options for the ET 350 monitor
Packing lists The basics The ET 350 monitor will arrive with the following items. Inspect the monitor for shipping damage and verify the contents of the box against this list:
3M Dynapro ET 350 monitor.
Floppy disks with MicroTouch NFI touch screen software and README files for Windows NT 4.0, Windows 9X and Windows XP/ 2000 operating systems.
Allen key (5/32-inch).
Full-scale cutout template.
Warranty card with detachable mail-in Product Registration Card.
3M Dynapro ET 350 Monitor User’s Installation Guide (this manual).
Model-specific packing lists In addition to the standard items listed above, each of the three ET 350 monitor models will come with different materials (for information on the distinctive features of each model, see “Distinctive features of each model” on page 8):
NEMA 4X panel gasket
Screws and washers
Instructions for installing the NEMA 4X panel gasket
Power cable · Power cable

NEMA 4X hatch and extended hatch cover
NEMA 4X hatch gasket
Cable fitting components
Clear, flexible insulator
Instructions for installing the NEMA 4X hatch
The packing list for the KVM extender option appears on page 10.
Standard features The ET 350 monitor is an industrial flat-panel monitor with an integrated MicroTouch NFI touch screen with TouchSurround. The monitor is designed for rugged use in demanding industrial applications. The standard features of the ET 350 monitor are described below.
Display The display is an Active Color 15-inch Thin Film Transistor (TFT), Liquid-Crystal Display (LCD) and is capable of 1024 × 768 XGA resolution and up to 16.7M (million) colors.

Touch screen The monitor’s MicroTouch NFI touch screen consists of a chemically strengthened glass surface with a controller that measures disturbances in an electrostatic field near the surface of the screen.
Screws

The touch screen consists of the display area and the TouchSurround (Figure 1). Touches in the display area emulate the movements and actions of a mouse, and you can use your finger like a pointer. The TouchSurround can emulate keys on a keyboard.
The MicroTouch NFI touch screen provides highly accurate and clear optics, is extremely durable, and can be operated accurately with gloves. The touch screen does not require realignment to maintain touch accuracy, even with variations in temperature and humidity.
Software Touch screen drivers for the ET 350 monitor are included on the floppy disks that came with the monitor. The software supports:
Windows XP Professional operating system
Windows 2000 Professional operating system
Windows NT 4.0 operating system
Windows 98 and Windows 95 (Windows 9X) operating systems
For details on installing the touch screen drivers and utilities, see “Step 5: Install software and import TouchSurround files” starting on page 22.
Backlights The life expectancy of the backlights is about 35,000 hours.
If the host computer is running Windows XP, 2000, or 98 operating systems, you can extend the life of the monitor’s backlights by using the operating system’s energy saver. For details, see “Backlights saver” on page 25.
For information on replacing the backlights, contact 3M Touch Systems customer service (see “Contacting 3M Touch Systems” on page 3).

All ET 350 monitor units have the standard features described above. The distinctive features of each model are described below and summarized in Table A.
ET 350R monitor (NEMA 4X panel gasket) The ET 350R monitor has a UL Recognized component mark. It comes with a gasket that mounts between the monitor and a wall or panel (Figure 2).

The ET 350R monitor is suitable for Pollution Degree 3 environments if installed and tested with the panel gasket in an enclosure that meets NEMA 4X/IP66 ratings. If the ET 350R monitor is not mounted in such an enclosure or mounted without the gasket, the unit is suitable for Pollution Degree 2 environments.
ET 350L2 monitor (no gasket or hatch) The ET 350L2 monitor comes with neither a gasket nor a hatch. This model is UL Listed for Pollution Degree 2 environments and can perform as a stand-alone unit in a Pollution Degree 2 environment.
ET 350L3 (NEMA 4X hatch) The ET 350L3 monitor comes with a NEMA 4X hatch (and extended hatch cover) to seal both communication and power connections (Figure 3).
When properly installed with the materials supplied, the hatch provides a NEMA 4X/IP66 seal on all sides and the monitor is UL Listed for Pollution Degree 3 environments.
The ET 350L3 monitor may be used as a stand-alone unit in Pollution Degree 3 environments.



ET 350R
This model does not come with gasket or hatch.
(No on-site inspection required).
(No on-site inspection required).
Model Distinctive features

Options There are three types of options that may be ordered for the ET 350 monitor (not including mounting options, which are discussed on page 11):
Keyboard, video, and mouse (KVM) extender (single or dual) option
Fixed field wiring
The 3M Dynapro Moisture Deflector
Table B summarizes the options that are available for the ET 350 monitor models.
Monitor Model
KVM extender (single)
KVM extender (dual)
Field wiring
Moisture deflector
ET 350R Option
ET 350L2 Option Option n/a Option
ET 350L3 Option Option Standard Option
KVM extender (single or dual) option The ET 350 monitor may come with a keyboard, video, and mouse (KVM) extender option that allows the monitor to be located as much as 1000 feet (300 meters) from the host computer.
Packing list for KVM extender option If you ordered the ET 350 monitor with the KVM extender option, your package should include:
KVM local device
KVM remote device (built into the housing of the ET 350 monitor)
Combination keyboard, video, and mouse cable to connect the local unit to the host computer
KVM extender manufacturer’s manual
For more information on the KVM extender, see installation instructions in Appendix B.
Fixed field wiring Fixed field wiring is an option for the model that comes with a NEMA 4X panel gasket (ET 350R monitor) and is standard for the model that comes with a NEMA 4X hatch (ET 350L3 monitor). Fixed field wiring is not available for the ET 350L2 monitor.
For more information on field wiring, see “AC power supply with fixed field wiring (ET 350R monitor and ET 350L3 monitor only)” on page 17.
Serial cable

Moisture Deflector The Moisture Deflector is a durable plastic component that surrounds the touch screen display of the monitor and offers protection to the monitor from moisture that might collect on the unit.
The Moisture Deflector option can be supplied only when ordering an ET 350 monitor. It cannot be added to the monitor later.

For guidelines on mounting the ET 350 monitor with Moisture Deflector, see page 29. For information on handling and maintaining the ET 350 monitor with Moisture Deflector, see page 34.
Mounting kits Two of the three ET 350 monitor models come with their own mounting/ sealing equipment:
ET 350R monitor comes with a NEMA 4X panel gasket
ET 350L3 monitor comes with a NEMA 4X hatch
The ET 350L2 monitor does not come with mounting/sealing materials.
There are three optional mounting kits available from 3M Touch Systems for use with the ET 350 monitor. Each kit comes with its own set of instructions for mounting and sealing the unit:
Boom mount kit
Rack mount kit
Desktop kit

Table C summarizes the mounting possibilities for each of the ET 350 monitor models.
Monitor Model
NEMA hatch
NEMA panel
Desktop stand
Rack mount
Boom mount
ET 350R Option Standard Option Option Option
ET 350L2 n/a n/a Option n/a n/a
ET 350L3 Standard n/a Option n/a n/a
For more information about the mounting kits, see “Step 8: Mount monitor” on page 28.

Installing the monitor
About the chapter This chapter provides pre-installation recommendations and step-by-step instructions for installing the ET 350 monitor.
These steps outline a typical installation procedure for the ET 350 monitor. While most installations will follow these steps, your specific installation may differ.
Here is a summary of the steps for installing the ET 350 monitor:

Before installing Before beginning to install the ET 350 monitor, consider the following recommendations:
Get the latest video driver for your host computer’s video adapter card. To find out if your driver is the most current one, check the web site of the video adapter’s manufacturer.
Check the host computer’s monitor settings to make sure that the resolution is not greater than 1024 x 768.
The video (VGA) signal cable carries a video signal from the computer’s video adapter to the monitor. The ET 350 monitor comes with a standard 15-pin VGA cable that plugs into the monitor’s female connector. The standard cable length is 6 feet. There are 25-foot and 50-foot cable options available.

You may choose to use a standard signal cable or make a cable using the “Video signal cable connector” pin-out in Appendix C. When making a cable, 3M Touch Systems recommends you use a high-quality shielded cable such as Belden cables 1417B, 1418B, 1522A, or 1826A.

To connect the video signal cable, follow these steps:
The ET 350 monitor uses a 9-pin COM port for touch screen communication with the host computer. The standard length of the serial cable is 6 feet. There are 25-foot and 50-foot cable options available.
Use a standard cable or make one using the “Serial port RS-232C connector” in Appendix C. Note that the pin-out presents the ET 350 monitor as a Data Communication Equipment (DCE) device so that a “straight-through” cable can be used.
To connect the serial cable:

To reduce the risk of voiding FCC and CE compliance and reducing the performance of the ET 350 monitor, when making your own cable, reduce the sensitivity of the ET 350 monitor to electrical and radio frequency noise by connecting the cable shield to the connector shield (360º shield) on both ends of the cable.
The ET 350 monitor can be connected to an AC power supply in two ways: with a standard AC power cable or with fixed field wiring.
Standard AC power supply Use an AC power cable that is appropriate for the power scheme in your country or region:
For applications in Europe, use a harmonized AC power cable. The universal power supply of the ET 350 monitor automatically senses the voltage from the external source and, within the range 115 to 230 VAC, 50 to 60 Hz, supplies the appropriate power without requiring any adjustment.
For North American applications, use a standard AC power cable.
Both types of cable are available from 3M Touch Systems and come with either an IEC connector or terminal strip wiring.
Before attaching or removing communication cables, disconnect power to the ET 350.

To connect the AC power cable:
AC power supply with fixed field wiring (ET 350R monitor and ET 350L3 monitor only)
To connect the power supply with fixed field wiring, follow these steps:
To reduce the risk of fire or electric shock which could result in serious personal injury or death, when connecting power with fixed field wiring, the power cable must be double insulated. A clear, flexible insulator (supplied) must cover the portion of the cable that is not double insulated when connecting to a terminal strip connector.



DC power supply (option) To connect the ET 350 Monitor to DC power supply, follow these steps:

Open the enclosure To access the monitor’s controls, you must open it. To open the enclosure:
If your unit has security screws on the back of the bezel, remove
them with the appropriate screwdriver (the locations of the security screws are shown in Figure 13 on page 38).
Apply a 5/32-inch (4 mm) Allen key to the latch screw on the top of the enclosure. Turn the key counterclockwise ¼ turn, or until you feel the unit opening.
It is not necessary to fully open the enclosure to operate display controls. With the enclosure slightly ajar, you can access the display-setting controls (located on the back of the monitor’s display, near the top). Table D summarizes the functions of each on-screen control:

Symbol Name Function of the control Display controls inside ET 350 monitor enclosure

Menu To start up the on-screen display menus and to move through the menu options.
Left To move through main menu icons (PC, OSD, Utility, and Auto) and to decrease setting values.
Right To move through main menu icons (PC, OSD, Utility, and Auto) and to increase setting values.
Exit To exit the on-screen display menus. Changes are saved automatically.
Auto display setup Run the auto display setup before manually adjusting individual display settings. Auto display setup sets pre-programmed optimal display settings.
The display control menu appears on the screen and the PC icon at the top of the on-screen display is selected (Figure 9).


The display settings are automatically optimized.
Manually adjusting display settings If the auto display setup settings are not suitable for your application, you can make manual adjustments to the display settings. Follow these steps:
The control menu appears on the screen (Figure 9) and the PC icon at the top of the on-screen display is selected.
The display settings for the monitor are located in the PC menu.
The brightness setting is selected.

Other on-screen display options The most commonly used on-screen display options are those that appear under the PC and Auto icons. Other on-screen options that can be set using the controls are summarized below.
OSD (on screen display) menu The settings in the OSD menu permit you to change the position and appearance of OSD menus, the duration of a display before timeout, and the language (English or Korean) of the OSD menus.
By increasing or decreasing the value of H-Position, for example, the OSD menus can be shifted left or right on the display.
Utility menu The settings in the Utility menu allow you to reset display settings to the monitor manufacturer’s display setting defaults and to get information on the display’s current resolution and frequency. Some units allow the user to turn the display’s power management system (DPMS) on or off (the default setting is “on”). For the ET 350 monitor, the DPMS should not be turned off. For ET 35X monitors with heater, see installation instructions that come with heater units regarding DPMS settings.
To reduce the risk of electric shock or mechanical impact which could result in serious personal injury or death, if your ET unit has a display power management system (DPMS) that is configurable from the display’s on-screen utility menu, do not turn off the DPMS.
Installing touch screen software To install the touch screen drivers and utilities for the ET 350 monitor, follow the instructions below that correspond to the operating system running on the host computer. The ET 350 monitor currently supports Windows XP Professional, Windows 2000 Professional, Windows NT 4.0, and Windows 9X operating systems.
Installing the driver for Windows XP/2000 operating systems To install touch screen software for Windows XP or Windows 2000 operating systems:
The installation Welcome window appears.

Installing the drivers for Windows NT 4.0 and Windows 9X operating systems To install the touch screen software for Windows NT 4.0 and Windows 9X operating systems, follow these steps:
The installation Welcome window appears.
When the software is installed, you will be prompted to restart.
a. From the Windows operating system Start menu, select Settings,
then select Control Panel, and then open System.
b. Click the Device Manager tab, then open System Devices, and
then right-click ACPI BIOS and click Properties. A dialog box appears.
c. Click the Driver tab, then click Update Driver, and then click
Next.
d. Click Display a list of all the drivers, then click Next, and then
click Show all hardware. A dialog box appears.
e. From the Manufacturers options (on the left side of the dialog
box), select Standard System Devices and from the Models options (on the right), select PCI Bus, and then select Next.

f. Click Yes in reply to the question: Are you sure you want to use
this driver? The Update Device Driver Wizard appears.
g. Insert your CD-ROM for the Windows 98 operating system. (If
the CD-ROM welcome page appears, close it so you can see the Wizard dialog box.)
h. Click Next in the Wizard dialog box and, after a message appears
confirming that the Windows operating system has finished its task, click Finish.
i. Click Yes when the System Settings Change box appears asking if you want to restart your computer.
j. After restarting the computer, confirm that the driver and controller are communicating.
Windows XP/2000 operating system To import the standard TouchSurround definition for Windows XP and Windows 2000 operating systems, follow these steps:
A dialog box appears asking whether you want to add the TouchSurround definition file information to the registry.
A dialog box appears verifying that the file transfer has occurred.
The TouchSurround button definition dialog box appears.
The Configuration Utility dialog box re-appears. The standard button definition file takes effect immediately. It is not necessary to reboot.
Windows NT 4.0/9X operating systems The standard TouchSurround definition for Windows NT 4.0 and Windows 9X operating systems is imported when installing the driver. If you can’t find the TouchSurround definition file, you may need to reinstall the software. Refer to the software guide appropriate for your operating system (see “Software guides” on page 2).

To import the standard TouchSurround definition for Windows NT 4.0 and Windows 9X operating systems, follow these steps:
CD\TOUCH\NT for Windows NT
CD\TOUCH\W9X for Windows 9X
The standard TouchSurround button configuration takes effect the next time you start Windows NT 4.0 or Windows 9X operating systems.
Customizing drivers Some of the driver features that can be customized include double touch settings, touch screen sensitivity, and beep on touch. For instructions on how to customize driver features, refer to the appropriate software guide (see “Software guides” on page 2).
Backlights saver You can extend the life of the monitor’s backlights (and conserve power) by setting the host computer’s energy saver to “turn off the monitor” after a specified number of minutes of inactivity. The energy saver (which is, in effect, a backlights saver) is adjusted in the Display Properties dialog box of Windows XP, 2000, and 9X operating systems.
Windows NT 4.0 operating system does not have an energy saver, so if the host computer is running with Windows NT 4.0 operating system, the backlights will be on whenever the unit is powered up (even if the Windows NT 4.0 operating system screen saver is set to display a blank screen).
Safe touch This setting changes the way the touch screen responds when the user touches the screen to reactivate the monitor following a period when the backlights have been off.
With a safe touch setting applied, the user will not accidentally activate a touch screen button on the part of the screen that is touched.

If the ET 350 monitor is running an application or is in a setting in which unintentionally activating a button on the touch screen might have harmful consequences for people or equipment, 3M Touch Systems recommends creating a “safe touch” setting.
To reduce the risk of electric shock or mechanical impact which could result in serious personal injury or death: • Apply a “safe touch” setting, especially if the monitor is running an application or is in a setting where safety is a concern.
The procedure for applying a safe touch setting differs depending on the operating system.
Safe touch for Windows XP/2000 operating systems To apply a safe touch setting with Windows XP and 2000 operating systems, follow these steps:
The power dialog box appears (called Power Scheme in Windows XP; called Power Options Properties in Windows 2000).
To reduce the risk of electric shock or mechanical impact which could result in serious personal injury or death, set the “safe touch” setting correctly, with the number of minutes entered for the Windows operating system energy saver being at least one minute greater than the time entered for the Windows operating system screen saver.

Safe touch for Windows 9X operating system To apply a safe touch setting with a Windows 9X operating system, follow these steps:
The power management dialog box appears.
To reduce the risk of electric shock or mechanical impact which could result in serious personal injury or death, set the “safe touch” setting correctly, with the number of minutes entered for the Windows operating system energy saver being at least one minute greater than the time entered for the Windows operating system screen saver.
Safe touch for Windows NT 4.0 operating system Windows NT 4.0 operating system does not have an energy saver, so it is not necessary to apply a safe touch setting with this operating system.

Close enclosure When you are finished adjusting the display settings, close the enclosure:
Close hatch To close the hatch, insert the four #6-32 Phillips screws loosely. Using a No. 1 Phillips torque screwdriver, gradually tighten diagonal pairs of screws until all are equally tight at a torque of 7 inch-pounds. This may require about three rounds of tightening.
Two of the three ET 350 monitor models come with their own mounting/ sealing equipment and mounting instructions (and the instructions are also available for download from www.3Mtouch.com):
ET 350R monitor with a NEMA 4X panel gasket
ET 350L3 monitor with a NEMA 4X hatch
The ET 350L2 monitor does not come with mounting materials, but there are optional mounting kits available from 3M Touch Systems (see below).
For details of the features of the three ET 350 monitor models, see “Distinctive features of each model” on page 8.
Optional mounting kits Each mounting kit comes with its own set of installation instructions (also available for download from www.3Mtouch.com):
Boom mount kit allows the monitor to be mounted on a post, boom or suspension arm with a NEMA 4X sealed hatch or extended hatch.
Rack mount kit makes it possible to mount the monitor on a standard 19-inch industrial rack.
Desktop stand kit is a two-piece desktop stand option that allows the monitor to be set on a desk, bench, or table top.
A security hardware kit, also available from 3M Touch Systems, includes four security screws and a security screwdriver that make it possible to lock the back of the ET 350 monitor enclosure. Once the security screws have been inserted, the monitor cannot be opened from the front by an unauthorized user.
To reduce the risk of electric shock which could result in serious personal injury or death, before removing the ET 350 monitor from its mounting, disconnect power to the unit.

The locations for attaching the security screws are shown in Figure 13 on page 38.
Mounting the ET 350 monitor with Moisture Deflector The ET 350 monitor with Moisture Deflector comes with four sealing screws fastened to the back of the unit. 3M Touch Systems recommends that if you need to remove the sealing screws to access the enclosure, you re-attach the screws after closing the enclosure.
The ET 350 monitor with Moisture Deflector must be mounted vertically—with no more than 10 degrees variance from vertical—for the Moisture Deflector to operate. As long as the 10 degree rule is observed, it is possible to mount the monitor with the Moisture Deflector using any of the mounting kits described above.



Maintaining the monitor
About the chapter This chapter describes how to:
Clean the touch screen and enclosure
Replace the fuse
Check gaskets for damage or improper functioning
Maintain the ET 350 monitor with Moisture Deflector
Cleaning Cleaning the touch screen When cleaning the front surface of the NFI touch screen, use any chemical that does not corrode glass. The touch screen will function, even if its front surface is pitted or damaged by a chemical.
Replace backlights

Cleaning the enclosure Use a 50 percent solution of alcohol (ethanol or isopropanol) in water on a cotton gauze pad or soft cotton cloth to clean the enclosure. Be sure to apply the alcohol solution to the cloth only, not directly to the enclosure.
To reduce the risk of fire or explosion which could result in serious personal injury or death, when using a flammable or combustible cleaning solution or fluid on or near the ET 350 monitor, refer to the cleaner manufacturer’s material safety data sheet and follow all instructions and recommendations.
For information on replacing backlights for the ET 350 monitor, contact 3M Touch Systems customer service (see “Contacting 3M Touch Systems” on page 3).
Replacing the fuse The fuse holder is adjacent to the power socket of the ET 350 monitor.
3/16-inch flat-blade screwdriver
No. 1 Phillips torque screwdriver (for ET 350L3 monitor)

The fuse holder will pop out of the ET 350 monitor.
Checking gaskets Follow these guidelines to check and clean the gaskets on your monitor:
Make sure there is no debris on gaskets that will prevent a seal.
If debris needs to be cleaned from gaskets, do so gently.
If gaskets are torn or damaged, return to 3M Touch Systems for servicing.

The Moisture Deflector is made of durable plastic and, like other 3M Dynapro components, is designed to function in rugged conditions.
It is not indestructible, however. Follow these guidelines to extend its life and help ensure optimal performance:
Before starting the ET 350 monitor with Moisture Deflector, make sure that the temperature is at least 0ºC.
Do not hang anything from the Moisture Deflector. Doing so may cause it to perform poorly.
Before opening the enclosure of the ET 350 monitor with Moisture Deflector, make sure that the unit is completely dry. If water has collected on the top of the enclosure and is not removed before opening it, moisture might run into the unit.
To open the unit, you will need to remove the four sealing screws attached to the back of the unit. After closing the enclosure, re-attach the sealing screws.
When handling the monitor, do not grasp it by the Moisture Deflector.
If it is necessary to ship the monitor for any reason, use the original packing materials, if possible. When packing the unit, take care to protect the Moisture Deflector from being damaged during shipping.

TouchSurround and graphic underlay
About the chapter This chapter describes:
The function of the TouchSurround and graphic underlay
How to get a custom underlay
How to replace the underlay
The TouchSurround is the touch-sensitive area of the computer screen around the LCD display (see Figure 1 on page 6). A graphic underlay is located under the touch screen and it identifies buttons, touchable symbols, pictures, and icons.
Standard TouchSurrounds Standard TouchSurround layouts from 3M Touch Systems feature predefined buttons that permit some keyboard functions (for example, Enter) to be performed by touch. The functions of the buttons can be changed by following instructions in the software guide appropriate for your operating system (see “Software guides” on page 2).
Custom TouchSurrounds Custom TouchSurrounds let you customize the user’s interface with the monitor. You can change the number, size, and position of buttons, and create icons or touchable graphics that suit your needs.
If you need a custom TouchSurround, you can order the monitor with a custom TouchSurround or you can replace the TouchSurround graphic underlay later, as described in this chapter.

Creating your own graphic underlay If you need a custom graphic underlay, it is recommended that you order it from 3M Touch Systems, especially if the underlay will need to withstand temperature and humidity extremes.
The monitor is designed to operate in temperatures from 32°F to 122°F (0°C to 50°C), and with humidity up to 95% (non-condensing). If you do not need this level of durability, you may choose to print the underlay yourself. There are two possible methods:
Silk screen printing onto a clear, soft, matte finish polycarbonate sheet. 3M Touch Systems recommends that you use a sheet that is 0.015 inches thick and printed on the “back” side (to prevent the printed surface from touching the glass).
Inkjet or color laser printing onto paper or a plastic sheet. Avoid having the printed surface in direct contact with the touch screen— under certain conditions it could adhere to the glass. Laminate the underlay with clear matte-finish plastic to prevent contact between the printed surface and the glass.
With either method, make sure the surface in contact with the glass has a matte finish to prevent the optical distortion known as Newton’s Rings.
After installing a new underlay, you will need to define new positions, actions and functions for your buttons or icons. For instructions on doing this, refer to the appropriate software guide (see “Software guides” on page 2).

What you will need The rest of this chapter describes how to remove the graphic underlay that came with your monitor and replace it with a new, custom underlay.
To do the tasks described in this section, you will need:
A clean, ESD-protected environment with a work bench.
Two people: one to replace the underlay and another to support the monitor.
The following tools and materials:
5/32-inch (4 mm) Allen key (supplied with the monitor)
5/16-inch torque hex nut driver
Latex or cotton work gloves
Cleaning solution and cloths designed for cleaning coated optical glass
Security screwdriver, if the enclosure is secured with security screws
To prevent damage from electrostatic discharge (ESD), wear a grounding wrist strap when working with electronic components inside the enclosure. Follow the instructions that accompany the wrist strap. If a grounding strap is not available, touch a grounded metal object to discharge any static charge from your body.
To reduce the risk of electric shock which could result in serious personal injury or death, before removing the ET 350 monitor from its mounting, disconnect power to the unit.
a. Disconnect all communication connections from the monitor. For
more information about connections, see Chapter 2, starting at page 13.
b. Remove the monitor from its mounting.
c. Lay the monitor on a flat surface. You may want to place foam
pads or other material underneath the unit to protect the front surface of the touch screen and its bezel.

If your unit has security screws on the back of the bezel, remove them with a security screwdriver (the locations of the security screws are shown in Figure 13).

Apply a 5/32-inch (4 mm) Allen key to the latch screw on the top of the enclosure. Turn the key counterclockwise ¼ turn, or until you feel the unit opening.

a. Gently pull out the touch screen connector’s retaining clip with
two fingers.
b. Gently pull the touch screen tail from the controller and through
the ferrite block.




a. Lift the hinge side of the display pan up from the threaded studs.
b. Slide the display pan away from the other two threaded studs.
c. Lift the display pan to a vertical position.
The glass surface under the underlay marks easily. Do not touch or scratch the glass while replacing the underlay. If you do touch the glass and leave stains or fingerprints, clean it before you install the new underlay.



To loosen the underlay from the glass surface, use a finger and push a corner of the underlay towards the center of the glass. As the underlay buckles and the corner comes into view, pull it up to clear the retaining frame. Repeat at each corner until the underlay is free (Figure 17).



Tighten the nuts to a torque of 10 inch-pounds.

a. Pull out the touch screen connector’s retaining clip.
b. Slide the touch screen tail through ferrite and insert it into the
connector.
c. Press the retaining clip back into the controller.


Troubleshooting
About the chapter This chapter outlines problems that may occur when using the 3M Dynapro ET 350 monitor and suggests solution strategies. If problems persist after following the applicable instructions in this chapter, contact 3M Touch Systems technical support (see page 3).
*Note: References to “serial device” in the KVM manufacturer’s manual denote the “touch screen” of the ET 350 monitor.
Problem Solution

ET 350 monitor does not power up when plugged in.
Try the following: 1. Make sure that the power to the monitor’s power cable is turned on.
After manually aligning the TouchSurround buttons, alignment of the touch screen is unsatisfactory.
Keyboard/mouse not functioning for the ET 350 monitor with KVM extender option.
*Note: References to “serial device” in the KVM manufacturer’s manual denote the “touch screen” of the ET 350 monitor.
Problem Solution

The touch screen drivers can detect error conditions that are independent of the operating system. If you see one of the following error messages, please note the number displayed with it. This will help 3M Touch Systems technical support staff to diagnose the problem (see page 3).
9002: Unable to communicate with touch controller. Check COM port settings and cabling.
91xx: Touch controller image error detected.
91xx: Unrecoverable EEPROM failure detected in touch controller. Touch screen is inoperable. Servicing is required.
91xx: Touch controller failed RAM or ROM test. Touch screen is inoperable. Servicing is required.
Error message Solution



Specifications
Enclosure and cutout dimensions

355.60 mm high × 414.02 mm wide × 160.53 mm deep
Panel cutout 12.33" high × 14.36" wide 313.18 mm high × 364.74 mm wide




Viewing area 11.97" (304.1 mm) horizontal
8.98" (228.1 mm) vertical
15" (381 mm) diagonal
Pixel format 1024 (horizontal)× 768 (vertical)
Type Active Color TFT
Panel colors (up to) 16.7M
Contrast ratio 300:1 (typical)
Viewing angle (typical) H ± 65°
V +50° to -60°
Brightness (typical) 250 cd/m2(typical)
Mode Resolution VESA Horizontal frequency (kHz)
VGA 640 × 480 640 × 480 43.27 85.0 36.000
SVGA 800 × 600 800 × 600 53.67 85.1 56.250
XGA 1024 × 768 1024 × 768 68.67 85.0 94.500
The bezel provides resistance to user abuse and to most chemicals and other substances. Contact 3M Touch Systems technical support for guidelines on protecting the equipment from specific chemicals.
Windows 2000 Professional operating system
Windows NT 4.0 operating system
Windows 98 operating system
Windows 95 operating system

Serial Touch screen interface to host computer
RS-232C compatible asynchronous serial port
9-pin female D-connector
VGA Video interface to host
VGA signal cable port
15-pin female VGA connector
Analog RGB 0.7V p-p
TTL level SYNC
CAT5 Interconnection between KVM remote and local units
Monitor with KVM extender
Two 6-pin mini-DIN female connectors for keyboard and mouse output to computer
AC power units 1.0 A 250 VAC Type T Littelfuse 215.001
Schurter 0001.2504
DC power units 4A 250V, Type T Bussmann GDC-4A
AC power source IEC connector or 3 terminal strip
Input range 115/230 VAC autoranging
Input current 0.6A @ 115 VAC
DC power supply
DC power source 3 terminal strip
DC power input 22-28 VDC (typically 24 VDC)
DC input current 2A

0°C to 50°C (32°F to 122°F)
Humidity 50°C, 5% to 95% non-condensing
6,560 feet (2,000 meters)
Vibration 5 to 57 Hz 0.006 in peak displacement 58 to 2000 Hz 1.0 G acceleration
Storage temperature -25°C to 60°C (-13°F to 140°F)
40,000 feet (12,192 meters)
Vibration 5 to 57 Hz 0.015 in peak displacement 58 to 2000 Hz 2.5 G acceleration
UL 60950 (3rd edition)
for Information Technology Equipment
CSA C22.2 No. 950-1995
for Information Technology Equipment via UL’s C-UL certification
NEMA 250 Electrical Enclosures, Type 12, Type 4, Type 4X
IEC 529 Degrees of Protection Provided by Enclosures, IP66

FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
The ET 350 monitor complies with the CE mark related to the Low Voltage Directive 73/23/EEC as confirmed in the Declaration of Conformity.
The ET 350 monitor complies with the CE mark related to the EMC Directive 89/336/EEC as confirmed in the Declaration of Conformity.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appariel numerique de la classe A respecte toutes les exigences due Reglement sur le material brouilleur du Canada.
Electromagnetic compatibility immunity standards EN61000-6-2
Electrical fast transient EN61000-4-4
AC sags and dropouts EN61000-4-11

FCC CFR 47, Part 15, Subpart B, Class A
C-Tick — Australia, New Zealand
UL Information Technology Equipment — United States
ET 350R monitor (with panel gasket)
UL recognized component for Pollution Degree 3 environments if
installed and tested with panel gasket in an enclosure that meets NEMA 4X/IP66 rating.
UL recognized for Pollution Degree 2 environments if not mounted or if
mounted without the supplied gasket.
ET 350L2 monitor (without hatch and without panel gasket)
UL listed for Pollution Degree 2 environments.
ET 350L3 monitor (with NEMA 4X hatch)
UL listed for Pollution Degree 3 environments.
C-UL Information Technology Equipment — Canada
CE Information Technology Equipment — Europe
Touch screen drivers emulate Microsoft mouse driver.
Utility to configure TouchSurround emulates 101-key enhanced PC-compatible keyboard.
EN55022 Class A · ICES-003 Class A



Installing monitor with KVM extender
About this appendix
This appendix provides instructions for installing the ET 350 monitor with the keyboard, video, and mouse (KVM) extender option. For more information about the KVM extender, refer to the manufacturer’s manual that came with your ET 350 monitor.
The KVM extender option allows the monitor to be located up to 1000 feet (300 meters) from the host computer. The KVM extender has a local unit and a remote unit. The remote unit is built into the housing of the monitor.
Cable-length jumpers There are three cable-length jumpers on the remote unit of the KVM extender’s circuit board, inside the monitor’s enclosure (Figure 22).


These jumpers (JP3, JP4, and JP5) can be set to adjust equalization of the monitor’s display to compensate for loss of image quality due to the signal passing through a long cable.
If the length of the cable running between the local and remote units is 655 to 1000 feet (200 to 300 meters), which is the default setting for the ET 350 monitor, the jumpers should not need adjusting.
To set the cable-length jumpers:
If the cable is this length Set the three cable-length jumpers like this
655 to 1000 feet (200 to 300 meters)
Default setting for ET 350 monitor.
330 to 655 feet (100 to 200 meters)
0 to 330 feet (0 to 100 meters)
Off

If the length of cable between the local and remote units is near the high end of one of the ranges and you are using high-resolution video (1024 x 768), try setting jumpers for the next higher cable length. This might help improve video compensation.
Keyboard and mouse control The ET 350 monitor DIP-Switch SW1 on the KVM extender board is set to off (see Figure 22). With this setting, the monitor user can take control by pressing a key on the keyboard or by moving the mouse.
The DIP-Switch default setting for the ET 350 is off. This is different from the default setting that appears in the KVM extender manufacturer’s manual.
If you prefer that users not be able to take control simply by typing on the keyboard, the DIP-Switch will need to be switched to the on position.
To change the DIP-Switch setting:
If your unit has security screws on the back of the bezel, remove them with a security screwdriver (the locations of the security screws are shown in Figure 13 on page 38).
Apply a 5/32-inch (4 mm) Allen key to the latch screw on the top of the enclosure. Turn the key counterclockwise ¼ turn, or until you feel the unit opening.

To connect communications cables, follow these steps:
To help ensure optimal performance and to reduce the effect of interference, route the CAT5 cable away from generators, motors, compressors, fluorescent lights, and other cables.


Remaining steps Continue the installation steps in Chapter 2, beginning with Step 3 on page 16:



Connector pin-outs
Video signal cable connector Pin Signal
5 Vertical sync. return
10 Horizontal sync. return
12 N.C.*
13 Horizontal sync.
14 Vertical sync.
*N.C. = No Connection

2 RXD Receive Data OUT
3 TXD Transmit Data IN
4 DTR Data Terminal Ready
5 SGND Signal Ground ---
7 RTS N.C.*
8 CTS N.C.*
9 RI N.C.*
*N.C. = No Connection

Pin Color Function, pair
1* White/Orange TX, Pair 2
2 Orange/White RX, Pair 2
3 White/Green TX, Pair 3
4 Blue/White RX, Pair 1
5 White/Blue TX, Pair 1
6 Green/White RX, Pair 3
7 White/Brown TX, Pair 4
8* Brown/White RX, Pair 4
*Looking into the interconnect socket on either the remote or local unit, or looking at the cable from behind, Pin 1 should be on the left and Pin 8 on the right.

3 GND
4 +5V
6 N.C.*
*N.C. = No Connection
Pin Signal · 1 Data · 5 Clock


G
Gaskets, checking & cleaning 33
immunity standards 54
cleaning 32 closing 28 dimensions 49 opening 19
touch screen drivers 47
certifications 55 installing 13–29 intended use i KVM extender 10 Moisture Deflector 11 mounting 28–29 mounting kit options 11–12 packing lists 5 registering 3 returning to 3M Touch Systems 3 safety labels iii safety standards 53 specifications 49–55 standard features 6–7
Jumpers, setting cable-length (KVM
K
Keyboard & mouse cable (KVM
connecting 60 pin-outs 66
Keyboard & mouse control
setting DIP-Switch SW1 (KVM
ET 350 monitor models. see ET 350R
connecting keyboard, video &
monitor, ET 350L2 monitor, and ET 350L3 monitor
mouse 60 defined 2 installing 57–61 keyboard & mouse control 59 packing list 10 setting cable-length jumpers 57– 59 setting keyboard & mouse
features 8 packing list 5
features 8 packing list 6
features 8 packing list 5
F
MicroTouch Near Field Imaging (NFI)
FCC compliance 54
cleaning & maintaining 34 mounting 29
boom mount option 28 desktop stand option 28 rack mount option 28

Near Field Imaging (NFI). see
Resistance to chemicals 51
MicroTouch Near Field Imaging
Returning ET 350 monitor to 3M Touch
Non-operating conditions 53
S
adjusting 19 auto display setup 20 before manually adjusting 20 controls 20 OSD menu 22 steps 21 Utility menu 22
described 25 Windows 9X operating system 27 Windows XP/2000 operating
Opening enclosure 19 – 20
Operating conditions 53
Security hardware kit 28
Operating systems supported by
connecting 15 pin-outs 64
Software specifications 55
Specifications 49–55 AC power supply 52 communications 52 DC power supply 52 display 51 display modes 51 drivers 55 dust & moisture resistance 53 fuse 52 non-operating conditions 53 operating conditions 53
ET 350L2 monitor 5 ET 350L3 monitor 6 ET 350R monitor 5 KVM extender 10
CAT5 cable (KVM extender) 65 keyboard & mouse cable (KVM
extender) 66 serial cable 64 video cable 63
CE and EMC emissions
compliance 54 electromagnetic compatibility
see AC power supply see DC power supply (option)
immunity standards 54 electromagnetic emission 55 FCC compliance 54 safety 53
Product certifications 55
Rack mount kit (option) 28

connecting 14 pin-outs 63
3M Touch Systems customer support 3 returns policy 3 trademarks ii
Video drivers, downloading latest 15
cleaning 31 defined 2
Windows 9X operating system
defined 2, 35 importing definition files 24 replacing underlay 37–44
backlights saver 25
Windows NT/9X operating systems
installing driver 23
Windows XP/2000 operating systems
TouchSurround. see also Graphic
installing driver 22 safe touch 25 setting backlights saver 25 setting safe touch 26–27
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.