Dell ® Wyse D Class Conversion to WES7
Products: D10D, D50D, D90DW


© 2014, Dell Inc. All Rights Reserved.
This manual and the software and firmware described in it are copyrighted. You may not reproduce, transmit, transcribe, store in a retrieval system, or translate into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, any part of this publication without express written permission.
End User License Agreement (“License”)
A copy of the End User License Agreement is included in the software and provided for your reference only. The License at http://www.wyse.com/license as of the purchase date is the controlling licensing agreement. By copying, using, or installing the software or the product, you agree to be bound by those terms.
The Dell, Wyse, and PocketCloud logos and Wyse and PocketCloud are trademarks of Dell Inc. Other product names mentioned herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. Specifications subject to change without notice.
You acknowledge that the Software is of U.S. origin. You agree to comply with all applicable international and national laws that apply to the Software, including the U.S. Export Administration Regulations, as well as end-user, end-use and country destination restrictions issued by U.S. and other governments. For additional information on exporting the Software, see http://www.microsoft.com/exporting
For availability, pricing, and ordering information in the United States and Canada, call 1-800-438-9973 or visit us at Dell.com. In all other countries, contact your sales representative.
Copyright Notices · Trademarks · Ordering Information


Figure 1 Kit contents (items may look different or not be included in your kit)


The warranty on the hardware component of this kit assumes the remaining months of warranty of the thin client in which it is installed, or for 90 days, whichever is greater. Installation of this kit will not void the factory warranty, however the user will be responsible for damage due to improper installation.
To convert your D class thin clients to WES7:
To access Dell technical resources, visit http://www.wyse.com/support If you still have questions, you can submit your questions using the Self-Service Center at http://support.wyse.com/selfservice.html or call Customer Support at 1-800-800-9973 (toll free in U.S. and Canada). Hours of operation are from 6:00 A.M. to 5:00 P.M. Pacific Time, Monday through Friday.
To access international support, visit http://www.wyse.com/global
Fact Sheets containing the features of hardware products are available on the Dell Web site. Go to http://www.wyse.com/products and use the Cloud clients tab to locate and download the Fact Sheet for your hardware product.
Administrator and other documentation for your cloud client model are available at: http://www.wyse.com/manuals
Dell maintains an online community where users of our products can seek and exchange information on user forums. Visit the Online Community forums at: http://community.wyse.com/forum

This chapter contains information for users of Wyse D class thin clients who must install new flash.
Figure 2 Removing the cover screws


4. Place your thumbs on the top surface of the opposite end where the three screws were removed. With a continuous motion, push firmly downward and towards the back panel (pushing down unlatches the hooks under the cover). The cover will shift approximate 1/4 inch to hang over the back panel. (a) Grasp the overhanging cover edge and raise the edge about 1-1/2 inches, and then (b) pull the cover out towards the back panel at the same angle to free the opposite end of the cover from the remaining hooks, as shown in Figure 3.
Figure 3 Removing the cover

Figure 4 Main-board shield

6. Using the Phillips Screwdriver, remove the five screws from the main-board shield (four corner screws and one screw mid-way along the front edge). Remove the main-board shield and unplug the speaker wires (red wire and black wire) to expose the main board and Flash module as shown in Figure 5. WARNING: Flash modules may be susceptible to damage by Electro-Static Discharge (ESD). All industry-standard cautions should be followed to avoid ESD. Before you remove or install a module, touch any metal part of the chassis and keep that contact with the chassis during the installation process.

Installing D Class Flash 5
Figure 5 Main board and Flash module

Figure 6 Removing the existing flash module


This page intentionally blank.

This chapter includes the requirements and procedures you need to install and use Wyse USB Firmware Tool to update your thin client to WES7 firmware.
TIP: The purpose of the USB Firmware Tool is to configure a bootable USB key for device firmware. In the following procedures, you will create a configured USB key containing the firmware contents that you need, and then boot from this configured USB key on appropriate product and flash size devices to push the contents of the USB key onto these target devices.
EXTREEMLY IMPORTANT: You must perform the steps to create and use the configured USB key on each thin client as noted. You cannot completely convert one thin client and then use the USB Firmware Tool to pull and push that image to your other thin clients.

Navigate to the D Class WES7 Conversion Image folder (contained on the Conversion Software Assembly DVD-ROM) and copy it to your local hard drive.
Figure 7 Wyse USB Firmware Tool wizard

Hard Drive · Firmware

Figure 8 Configuration options

Figure 9 Update firmware options - Windows Embedded Standard 7

6. Clear/uncheck the Preserve data partition check box. CAUTION: Details for Thin Clients Currently Using Multiple Data Partitions: Your existing custom data partition will not work with the WES7 firmware and you must rebuild your custom data partition after you convert to WES7. Although the Preserve data partition check box is automatically selected to preserve any existing custom data partition you may have on the thin client (useful for same firmware platform upgrading use cases), be sure to clear/uncheck the check box to remove the existing data in the custom data partition.

Figure 10 Browse for image file

Figure 11 Browse to select commandsXml.xml

9. Navigate to the D Class WES7 Conversion Image folder (on your hard drive) that contains the commandsXml.xml file (this is the location you selected in "Step 1: Copy the D Class WES7 Conversion Image Folder (on the DVD-ROM) to Your Local Hard Drive"), click on the commandsXml.xml file to select it (you may need to select the All Files option from the Files of Type box to display the commandsXml.xml file for selection), and then click Open. CAUTION: Be sure to use the commandsXml.xml file you extracted in "Step 1: Copy the D Class WES7 Conversion Image Folder (on the DVD-ROM) to Your Local Hard Drive"; DO NOT use the commandsXml.xml file directly from the Conversion Software Assembly DVD-ROM.
Figure 12 Prepare USB drive


In this step, you will boot each target device you want to convert from the configured USB key so that the USB key will push the contents from the USB key onto the target device. NOTE: BIOS selection, movement, and exit instructions are displayed in the BIOS window.
8. Press the F10 key to save, exit, and reboot the client from the configured USB key. When booting a target device from the configured USB key (containing the contents to be pushed to a target device), you will be prompted to continue with the push process (to continue, type y and press Enter). Once the push process is complete, the client automatically reboots several times. CAUTION: DO NOT interrupt the installation/conversion process. All process requirements are done automatically. The client automatically reboots several times. Some screens may display for several seconds during the process.

After the thin client displays the WES7 desktop, you can verify the Version and that your general client information is correct.
2. Click Close to close the Wyse Client Information window. The thin client is ready for operation and setup by an administrator. TIP: For security, automatic logon to a User desktop is enabled on the thin client by default (and is a member of the User group; not a member of the Administrator group). To log on as a different user or an administrator: Use the Log off button (Start > Log off) to log off the current desktop while holding down the SHIFT key until the Log On window displays. Log on as follows (passwords are case sensitive): Administrators - default Username is administrator and default case-sensitive Password is Wyse#123. Users - default Username is user and default case-sensitive Password is Wyse#123. Administrator and other documentation for your thin client model are available at: http://www.wyse.com/manuals
The conversion kit is supplied with Wyse Conversion Labels and Microsoft License Labels that must be attached to each thin client. Be sure you have purchased the amount of labels you need. CAUTION: Failure to install the label may cause delays in service and support. The serial number must be given to a Customer Support Technician to validate entitlement to support and service from Dell. Failure to do so will result in the original operating system being loaded on the device and is in breach of your license agreement.
Figure 13 Placement of Wyse Conversion Label (blank example)

Figure 14 Placement of Microsoft License Label (blank example)

Thin Client

After converting your thin clients, obtain any available firmware update at http://www.wyse.com/serviceandsupport/support/downloads.asp WARNING: Use of the Software on more than one device requires that you first purchase from Dell additional copies of, or licenses to, the Software. Contact your local Dell distributor or Dell Inside Sales at 1-800-800-9973 option 1 or 1-408-473-1200 option 1.
This section contains general troubleshooting information.
Due to different manufacturing processes on USB keys (and the variety of them), not all brands have been tested with the Wyse USB Firmware Tool. If you experience problems booting from a configured USB key, it is recommended that you try a different brand of USB key.
Problem: How can I properly use a SanDisk Cruiser flash drive to image supported devices using the Wyse USB Firmware Tool? (KB17735)
Solution: SanDisk flash drives come with support for U3. When you initially use these drives, you are prompted to select the use for the drive: Apps and Storage or only Storage. If you select the Apps and Storage option, the drive will create two partitions, one of which is identified as a CD and is a read only partition. This partition sometimes prevents the Wyse USB Firmware Tool to properly prepare the USB key for imaging a device. To resolve this problem you can go to http://www.sandisk.com go to support, search in the SanDisk Knowledge Base for document 2550, and then follow the instructions in the documentation to remove/uninstall U3 Launchpad.

Dell® Wyse D Class Conversion to WES7 Issue: 040914
Created using FrameMaker® and Acrobat®