Dell Po
owerEd
dge
C61 aseboa nageme Control
45 ard
Using
the Ba
Man
ent ller

Information in this publication is subject to change without notice. © 2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. Linux® is a registered trademark of Red Hat, Inc. in the United States and/or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
February 2011 Rev. A00





This section introduces the BMC and includes the requirements for web-based graphical user interface (GUI), keyboard, video, and mouse (KVM), and virtual media.
The following lists the supported features of the BMC:
Support for IPMI v1.5 and v2.0
Out-of-band monitoring and control for sever management over LAN
Dedicated 10/100 NIC for remote management over a network
Information which includes main board part number, product name, manufacturer, and so on.
Health status/hardware monitoring report
View and clear events log.
Event notification using chassis LED indicator and Platform Event Trap (PET)
Platform Event Filtering (PEF) to take selected action for selected events, including NMI and SMI
Chassis management including power control and status report, front panel buttons, LED control, Secure Mode, and Boot Option
Watchdog and auto server re-start and recovery
Multi-session user and alert destination for LAN channel
IPMB connector to enable advanced server management communication with BMC
Introduction | 5

The BMC firmware features an embedded web server, enabling users to connect to the BMC using an Internet browser (Microsoft Internet Explorer) without needing to install KVM and virtual storage software on a remote console.
Web-based GUI is supported on the following browsers:
Microsoft Windows:
Internet Explorer 6 or later
Mozilla® Firefox® 2.0017 or later
Mozilla Firefox 2.0017 or later
Enter the BMC-embedded server IP address or URL into the address bar of the web browser. The BMC interface has a default of (DHCP\Static). Enter the system BIOS setup with to change these settings.
When connecting to the BMC, the login screen prompts for the username and password. This authentication with Secure Sockets Layer (SSL) protection prevents unauthorized intruders from gaining access to the BMC web server. Once authentication is passed, you can manage the server by privilege. At the same time, the PHP Hypertext Preprocessor (PHP) records all user information, including user ID and privilege.
Using the WEB UI | 6

oller:
The Remote M (GUI) called th to use. It has a
ontroller has a u
user-friendly G troller GUI. It i it uses a standa
nagement Cont curve because i
is designed to b ard Internet bro
be easy owser.
When you first prompted to en password for lo
t try to access y nter a user nam
your Remote M me and password
ontroller, you a sts the user nam troller.
d. Table 1-1 lis nagement Cont
ogging on to th
Table Error! No Password
nt.-1. BMC Defa
ult User Name a
user name and pa
assword are in lowe
er-case characters.
og in using the root ers. Change your ro
t user name and pa oot password after l
logging in for the fir
ime.
Using the WEB UI

Managem
ment Con
troller GU
UI Explai
ned
After you succ greeted with th
to your Remot nagement Cont
roller GUI.
Log out from y
meout value is 3
30 seconds.
nformatio
on
Click the Syste The System In firmware revis
em Informatio nformation tab
on tab to view t b enables you to ware revision, a
the Remote Ma o view the Sys and build time.
ntroller. atus,
nt.-2. BMC Infor
vision.
re was last buil
lt in the form:
M DD YYYY
HH:MM:SS
Using the WEB UI

The List FRU p in the system. information.
page shows a l Select a FRU i
list of the detec
cted Field Repl drop down list t
aceable Units ( to show more
tem from the d
and the Serial N
FRU.
d Part Number.
L N
Lists the Manu Number.
Using the WEB UI

ealth
The Sensor me speed, internal
nformation abo and voltage.
dware such as t
Sensor Readi
ings & Senso
r Readings w
with Threshold
ds
It reads the sen category. You click “Show T
nsor informatio u can click “Re Thresholds” to
on the system. Y
a sensor type tate. And you c y sensor.
fresh” to re-rea
ad the sensor s sholds of every
Using the WEB UI

T m C i t
The System Ev managed syste Controller (BM information ab type and a shor
vent Log (SEL) em. The SEL is MC) or BIOS o
s that occur on
generated by t n the managed ents: event ID,
the Baseboard d system. The S
Management SEL lists the fo
rt description.
Select Server H information.
nu bar. Click Ev
vent Log to vie
The list can be categories, BM Generated Eve select. Subsequ
e sorted by sele MC Generated E
cting any even Events, BIOS G Management Sof
nt log category Generated Even
y. There are six
ler, FCB n you can
and Unknown ons, Local and
me Zone. Ther
e are two optio
GMT.
vent Log to Cl
lear the SEL.
sing the WEB UI

ration
W c T a
When the BMC component fail The Alerts win activate the ale
C senses a plat
form event, suc message can be
ch as an enviro
lure, an alert m ndow enables y erts for each ad
sent to one or m mail addresses,
dresses. and to
you to enter em ddress.
To set up a des
er, click Modi
ify.
Using the WEB UI

sing the WEB UI
Us · | 13

Alert Type, the
ere are two opt
3 Select E Informa
y, The five opti
ions available a d Non-recovera
are, Disable Al able.
ion IP.
Using the WEB UI

5 If your enter a b
Alert Type is brief descriptio
Email, enter th on for the Subj
ject of the ema
ave.
sing the WEB UI

It is an option t mode depends
to set up mous
e mode which t accurate mous
will using in K se pointer.
KVM. Setting m
on OS can get
e for host’s sys
e for host’s syst
tem is Linux O
OS.
Show the Rem DHCP or STA
rmation. You c
ATIC IP then cl
ick “Save”.
Using the WEB UI

Set E-mail (SM click “Save”.
sing the WEB UI

The Users pag users. You can accessing privi
ge enables you t n control user w
to view inform who can login R
figure existing gement Control
ileges.
s list for existin
ng BMC users.
nt.-3. BMC User
D number.
login name of t
the user.
Displays the g the user is ass User, Custom
group (privileg signed. (Admin m, or None).
ge level) to whi
There are three User.
ify User and D
To add new us
er, click their u
er, in the User
rs list. Click Ad
dd User.
Using the WEB UI

Enter user nam privileges, clic
ck Add.
sing the WEB UI

To change the Click Modify U
settings for a u User.
r user ID num
ber, in the Use
ers list.
Modify user na privileges, clic
ame, IPMI vers ck Modify.
To delete new User. A dialog refresh page.
user, click thei g box appears, c
ir user ID num click yes to del
mber, in the Us
sers list. Click nd automaticall
lete the user an
ers permission to co
onfigure a BMC use
tions are not availab
Using the WEB UI

Control
T
This feature en and reset the s
inistrator to po ly.
r off, power cy
Select Remote Control Oper
e Control in m
enu bar. Click -4 list the powe
Power Contro er control opera
ol. Select a Pow
ation. Table 1-
nt.-4. Power Con
Reboots sys boot).
the system.
Power Off Sy Immediate
Soft Shutdow Orderly Shutd
system.
the system.
Powers off, boot).
sing the WEB UI

m Action to ena
n.
T k o c
The Console R keyboard on th on a remote ma console redirec
Redirection pa he local manage
u to use the disp
to control the c
anaged system ction sessions.
. You can run a
N h la V
can use the conso me environment ins e host system. If the
le redirection featur stalled. This feature e BMC detects that ted to install it.
re, your browser m e needs Java 1.5.15
ater installed on the Viewer is not installe
t the Java Video
ed, you are prompt
s the Console is refe
erred to as the Ses
sion Viewer.
N c th m
mended display res 80 x 1024 pixels at creen mode if your
solution on the man
60 Hz with 32 bit c monitor resolution
olor. You cannot vi is less than this
he console in full sc minimum.
T t a n Using the WEB UI
The most powe to redirect the h ability to mana not.
Management C direct the host s were physically
e ability ole is the
host system’s c age your host sy
console. To red
system’s conso y in front of you
ystem as if it w

e check your M
Mouse mode.
If the host’s OS
S is Linux, ple
If the host’s OS
T
This menu item system.
m allows you to
o start a Remot
sion with the ho
edirection.
sing the WEB UI

ava Console.
m to Sync Curs
sor.
Using the WEB UI

T m b w
The Device me media enables be available on were present o
u to virtualize a
e or drive. Virt drive on your sy
tual ystem to drive
a floppy image n the managed
or CD/DVD d ole as if the flop
system's conso tem.
ppy image or d
n the local syst
The Device me drive, or ISO im virtualized.
enu in KVM di
isplays the flop management c
ppy image, flop console that is
mage on the m
nable virtual media f
for one floppy/drive mage for each med drive is treated as a
e image and one
ge. Only one drive/i
dia type can be a floppy drive.
. A USB key/flash d
sing the WEB UI

Devices
T w t c i
The Device cli window. To vi the table. The d checkbox. And image is added
ient displays th irtualize a devic
he list of device
r mapping in th e Mapped colu unmap, deselect
he main umn of
ce, select the ch o the server at t
heckbox in the his point. To u ith the dialog th
device maps to d then select th d to the list of a
t the d. The
e image file wi available device
es.
You can select check box for a read only whic
t a drive to beco
ome a virtual m
selecting the M O images are alw
a particular dri ch cannot be ch
ve. CD/DVD D hanged.
Using the WEB UI

To unmap a vir drive. Because confirm the act
rtual media dri e some interacti
ive, select the M
k box for a parti
ion might be go
oing on with th mapped.
he drive, you m
ed virtual drive lette
er (Microsoft® Wind x®) may not be the
dows®) or device
t® Enterprise Linux m (management con
same as the drive
etter on this system
nsole).
sing the WEB UI

BMC KVM
The BMC KVM to provide acce Mouse, Option Control tag, cl
M client main m ess to functions
menu consists s available thro d Help. To lau Redirection.
of five menu o ough the viewe
are used board, Remote
ns, Device, and lick Console R
nch a KVM se
nt.-5. BMC KVM
This menu i Redirection
item can be use
ed to begin Con
This menu i Redirection
item can be use
ed to halt Cons
This menu i Redirection Redirection
item can be use
ed to stop Cons
and then start again.
This menu i Console Red
item can be use
ed to view the ull Screen mode
e.
ur client system’s s ou can view the hos
creen resolution to st system in true fu
e redirection.
Using the WEB UI

T
nt.-6. BMC KVM
This menu ite side Redirection.
em can be used > key when in C
to act as the ri Console
This menu ite side k
em can be used
to act as the ri onsole Redirec
ight- ction.
key when in Co
This menu ite side Redirection.
em can be used > key when in C
to act as the le Console
This menu ite side k
em can be used
to act as the le onsole Redirec
eft- ction.
key when in Co
This menu ite side
em can be used
to access the l ring a Console
ession. The fol
:
sing the WEB UI

This menu ite right-side
em can be used WINDOWS> ke
to access the ey during a Con llowing actions
ession. The fol
:
+DEL
This menu ite depressed the keys down sim that you are re
em can be used
to act as if you LT> and
,
edirecting.
y. For example
e:
rol mouse.
To solve prob WebBIOS.
Using the WEB UI

B
bandwidth.
s: Helps in adju
ution.
T
nt.-7. BMC KVM
Enable you the CD-ROM ROM drive
to start or stop M drive. You c
mputer.
sing the WEB UI

Dropdown Menu Items Description
Redirect ISO Enable you to start or stop the redirection of the ISO. You can choose the CD IMAGE file from client computer.
Redirect Floppy / USB Enable you to start or stop the redirection of the Floppy/USB drive. You can choose the Floppy/USB drive from client computer.
Redirect Floppy Image Enable you to start or stop the redirection of the floppy drive. You can choose the Floppy IMAGE file from client computer.
Use the Firmware Update feature to upgrade to the latest firmware version. The following data is included in the BMC firmware package:
Compiled BMC firmware code and data
Web-based user interface, JPEG, and other user interface data files
Updating the BMC Firmware
1 Select “Maintenance” in menu bar. Click Enter Update Mode
Using the WEB UI | 32
Firmware Update · Default configuration files

2 Browse file resi
e to, or Type th
e path on your
ides. xample:
Ex C:\
3 Select t Norma
he Update Typ l). ormal: An up
No val Fo wit num
on will occur o
only when the and version nu update the ima oduct and vers
e BMC umber. age sion
rget board, tar d update make
rget product a es the BMC u ard, target pro
thout validati mber.
are.
sing the WEB UI

5 A wind Compar
ow, telling that re the uploaded
t the firmware d image with ex
image has been xisting device f
n verified, app firmware versi
ears. ion.
6 Select t (The de
he Preserve C efault value is P
or Don’t Prese figuration).
tart Upgrade.
Using the WEB UI

al minutes.
ted. Close the s
out.
sing the WEB UI

click Log In t
to log in to the
BMC again.
Using the WEB UI
9 After th · he BMC resets, · | 36

Table Error! No text of specified style in document.-8. Sensors Threshold
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00 Voltage
14h PS 12V Actual_Reading (Volts) = Raw_Data x 0.062
0xD8 0xD4 0xCF 0xAB 0xAF 0xB4
15h PS 5V Actual_Reading (Volts) = Raw_Data x 0.026
0xD7 0xD3 0xCD 0xA9 0xAE 0xB3
16h Standby 3.3V Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6 0xD3 0xCD 0xA9 0xAD 0xB3
17h PS 3.3V Actual_Reading (Volts) = Raw_Data x 0.026
0xFF 0xFF 0xFF 0x00 0x00 0x00
18h PS 1.2V Actual_Reading (Volts) = Raw_Data x 0.0087
Sensors Threshold | 37

0x98 0x96 0x92 0x7D 0x7F 0x84
19h PS 1.1V Actual_Reading (Volts) = Raw_Data x 0.0087
0xFF 0xFF 0xFF 0x00 0x00 0x00
51h VCORE 1 Actual_Reading (Volts) = Raw_Data x 0.0083
0x64 0x62 0x5F 0x00 0x00 0x00
52h VCORE 2 Actual_Reading (Volts) = Raw_Data x 0.0116
0x70 0x6E 0x6B 0x00 0x00 0x00
53h VCORE 3 Actual_Reading (Volts) = Raw_Data x 0.0083
0x64 0x62 0x5F 0x00 0x00 0x00
54h VCORE 4 Actual_Reading (Volts) = Raw_Data x 0.0116
0x70 0x6E 0x6B 0x00 0x00 0x00 Temperature
21h MLB TEMP 1
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
22h MLB TEMP 2
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
23h MLB TEMP 3
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
24h MLB TEMP 4
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
Actual_Reading (degrees C) = Raw_Data
0x77 0x75 0x73 0x00 0x00 0x00
Actual_Reading (degrees C) = Raw_Data
0x77 0x75 0x73 0x00 0x00 0x00
Sensors Threshold | 38

Actual_Reading (℃) = Raw_Data
0x4E 0x4C 0x4B 0x00 0x00 0x00
Actual_Reading (℃) = Raw_Data
0x4E 0x4C 0x4B 0x00 0x00 0x00
Actual_Reading (℃) = Raw_Data
0x4E 0x4C 0x4B 0x00 0x00 0x00
Actual_Reading (℃) = Raw_Data
0x4E 0x4C 0x4B 0x00 0x00 0x00
2Ah FCB Ambien t1
Actual_Reading (degrees C) = Raw_Data (only support Sensor Reading, threshold unsupport)
0xFF 0x32 0x00
DIMM_ A1 to DIMM_ D8
Actual_Reading (℃) = Raw_Data
0x63 0x61 0x5F 0x00 0x00 0x00
0xFF 0xFF 0xFF 0x00 0x00 0x00
A3h PSU 1 POUT
0xFF 0xFF 0xFF 0x00 0x00 0x00
A4h PSU 2 POUT
0xFF 0xFF 0xFF 0x00 0x00 0x00
Sensors Threshold | 39

Table Error! No text of specified style in document.-9. Threshold Sensors Event
Sensor Name Sensor Type Events
Lower Critical – going low asserted
Lower Critical – going low deasserted
21h MLB TEMP 1
Upper Non-critical – going high asserted
22h MLB TEMP 2
Upper Non-critical – going high deasserted
Upper Critical – going high asserted
Upper Critical – going high deasserted
Upper Non-recoverable – going high asserted
Upper Non-recoverable – going high deasserted
Events Table | 40

Sensor Name Sensor Type Events
Upper Critical – going high asserted
Upper Critical – going high deasserted
Upper Non-recoverable – going high asserted
Upper Non-recoverable – going high deasserted
Upper Non-critical – going high asserted
Upper Non-critical – going high deasserted
Upper Critical – going high asserted
Upper Critical – going high deasserted
Upper Non-recoverable – going high asserted
Upper Non-recoverable – going high deasserted
Lower Non-critical – going low asserted
Lower Non-critical – going low deasserted
Lower Critical – going low asserted
16h STBY 3.3V
Lower Critical – going low deasserted
Lower Non-recoverable – going low asserted
Lower Non-recoverable – going low deasserted
Events Table | 41

Table Error! No text of specified style in document.-10. Non-threshold Sensors Event Table
Sensor Name Sensor Type
71h PEF Action 12h O4h PEF Action
23h 00h Timer expired, status only
74h AC Pwr On 09h 04h AC lost deasserted
73h ACPI Pwr State
22h 0Bh Legacy ON state
0Ch Legacy OFF state
07h 01h Thermal Trip 42h CPU2Status
40h SEL Fullness 10h 02h Log Area Reset/Cleared
05h SEL Almost Full
A5h PCI Bus 13h 04h PCI PERR
Events Table | 42

Sensor Name Sensor Type
00h Correctable ECC/other correctable memory error
01h Uncorrectable ECC/other uncorrectable memory error
05h Correctable ECC/other correctable memory error logging limit reached
75h Security 06h 05h Out-of-band Access Password Violation
AAh PwrLimitAlert 07h 05h DCMI Power management exception action
Events Table | 43

Table Error! No text of specified style in document.-11. IPMI Device Global Commands
Command NetFn CMD O/M Supported
Get Device ID App 01h M Yes
Warm Reset App 03h O No
Get Self Test Results App 04h M Yes
Manufacture Test On App 05h O Yes
Set ACPI Power State App 06h O Yes
Get ACPI Power State App 07h O Yes
Get Device GUID App 08h O Yes
Broadcast Commands:
Broadcast ‘Get Device ID’ App 01h O No
Table Error! No text of specified style in document.-12. BMC Device and Messaging Commands
Command NetFn CMD O/M Supported
Set BMC Global Enables App 2Eh M Yes
Get BMC Global Enables App 2Fh M Yes
Clear Message Buffer Flags App 30h M Yes
Get Message Buffer Flags App 31h M Yes
Enable Message Channel Receive App 32h O Yes
IPMI 1.5 / 2.0 Command Support List | 44

Command NetFn CMD O/M Supported
Read Event Message Buffer App 35h O Yes
Get BT Interface Capabilities App 36h O No
App 38h O Yes
Capabilities
Get Session Challenge App 39h O Yes
Activate Session Command App 3Ah O Yes
App 3Bh O Yes
Close Session App 3Ch O Yes
Get Session Information App 3Dh O Yes
Get Authentication Code Command App 3Fh O Yes
Set Channel Access Commands App 40h O Yes
Get Channel Access Commands App 41h O Yes
Get Channel Info Command App 42h O Yes
Set User Access Commands App 43h O Yes
Get User Access Commands App 44h O Yes
Set User Name Commands App 45h O Yes
Get User Name Commands App 46h O Yes
Set User Password Commands App 47h O Yes
Active Payload Command App 48h O Yes
Deactivate Payload Command App 49h O Yes
Get Payload Activation Status App 4Ah O Yes
Get Payload Instance Info Command App 4Bh O Yes
Set User Payload Access App 4Ch O Yes
Get User Payload Access App 4Eh O Yes
Get Channel Payload Support App 4Fh O Yes
Get Channel Payload Version App 50h O Yes
IPMI 1.5 / 2.0 Command Support List | 45
Get Channel Authentication

Command NetFn CMD O/M Supported
Master Write-Read I2C App 52h M Yes
Get Channel Cipher Suites App 54h O Yes
Suspend/Resume Payload Encryption App 55h O Yes
Set Channel Security Keys App 56h O Yes
Get System Interface Capabilities App 57h O Yes
Set System Info Parameters App 58h O Yes
Get System Info Parameters App 59h O Yes
Table Error! No text of specified style in document.-13. BMC Watchdog Timer Commands
Command NetFn CMD O/M Supported
Set Watchdog Timer App 24h M Yes
Get Watchdog Timer App 25h M Yes
Table Error! No text of specified style in document.-14. Chassis Commands
Command NetFn CMD O/M Supported

Get System Reset Cause (Note: RESTART CAUSE [3:0] AH= SOFT RESET (E.G. CTRL-ALT- DEL) -UNSUPPORT.
IPMI 1.5 / 2.0 Command Support List | 46


Set Front Panel Button Enable Chassis 0Ah O No
Table Error! No text of specified style in document.-15. Event Commands

Table Error! No text of specified style in document.-16. SEL Commands
Command NetFn CMD O/M Supported

IPMI 1.5 / 2.0 Command Support List | 47


Get SEL Time UTC Offset Storage 5Ch O Yes
Set SEL Time UTC Offset Storage 5Dh O Yes
Table Error! No text of specified style in document.-17. SDR Repository Commands
Command NetFn CMD O/M Supported

Get SDR Repository Allocation Info Storage 21h O Yes
Enter SDR Repository Update Mode Storage 2Ah O Yes
Exit SDR Repository Update Mode Storage 2Bh O Yes
Table Error! No text of specified style in document.-18. FRU Inventory Device Commands

Get FRU Inventory Area Info Storage 10h M Yes
IPMI 1.5 / 2.0 Command Support List | 48

Write FRU Inventory Data Storage 12h M Yes
IPMI 1.5 / 2.0 Command Support List | 49

Table Error! No text of specified style in document.-19. Sensory Device Commands
Command NetFn CMD O/M Supported

Set Sensor Reading and Event Status S/E 2Fh O No
Table Error! No text of specified style in document.-20. LAN Commands

IPMI 1.5 / 2.0 Command Support List | 50

Table Error! No text of specified style in document.-21. PEF/PET Alerting Commands

Set Last Processed Event ID S/E 14h M Yes
Get Last Processed Event ID S/E 15h M Yes
Table Error! No text of specified style in document.-22. SOL Commands
Command NetFn CMD O/M Supported
Set SOL Configuration Parameters S/E 21h O Yes
Set SOL Configuration Parameters S/E 22h O Yes
IPMI 1.5 / 2.0 Command Support List | 51

Table Error! No text of specified style in document.-23. OEM1 Commands (NetFn 30H, 31H)
Command NetFN cmd Format
OEM1 01H Request:
Response:
Byte 1 – completion code
Byte 2 - Reservation ID
IPMI OEM Command List | 52
Reserved Extended Configuration

Command NetFN cmd Format
OEM1 02H Request:
Byte 1 - Reservation ID
Byte 2 - Configuration ID
Byte 3 - Attribute ID. 00h means read entire configuration data.
Byte 4 - Index (used by table object only)
Byte 5 - Data Offset – LSB
Byte 6 - Data Offset – MSB
Byte 7 - Bytes to read. FFh means read entire configuration or attribute.
Response:
Byte 1 – Completion code (01h:no more data)
Byte 2 – Configuration ID
Byte 3 – Attribute ID
Byte 4 – Index (valid only for table object only)
Byte 5 – Number of bytes returned, 1-based
Byte 6~N – Data
(Please check with table 1-25 Extended Configuration)
IPMI OEM Command List | 53
Get Extended Configuration

Command NetFN cmd Format
OEM1 03H Request:
Byte 1 - Reservation ID
Byte 2 - Configuration ID
Byte 3 - Attribute ID. 00h means read entire configuration data.
Byte 4 - Index (used by table object only)
Byte 5 - Data Offset – LSB
Byte 6 - Data Offset – MSB
Byte 7 - In progress
[7:4] reserved
[3:0] in progress
Byte 8~N – Data to be written.
Response:
Byte 1 – Completion code (01h:no more data)
(Please check with table 1-25 Extended Configuration)
IPMI OEM Command List | 54
Set Extended Configuration

Command NetFN cmd Format
OEM1 04H Request:
Byte 1 -Configuration to be restored to defaults:
[7:5] 111b= Restore the remaining parameters not included in below lists.
000b= Remaining parameters stay what it is.
All other values are reserved
[4] 1b= Restore PEFs to defaults
[3] 1b= Restore serial configuration parameters to defaults
[2] 1b= Restore SOL configuration parameters to defaults
[1] 1b= Restore LAN configuration parameters to defaults
[0] 1b= Restore user accounts to defaults
Response:
Byte 1 –Completion Code
CCh = restore to one or more of the configuration not supported.
Byte 2 – Task ID.
Use the Task ID to get the restore status. The Task ID is automatically become invalid after 120 seconds when the restore requesting is completed. 00h reserved.
IPMI OEM Command List | 55
Restore to defaults

Command NetFN cmd Format
OEM1 05H Request:
Byte 1 – Task ID
Task ID, the value returned by previous call to Restore to Defaults command.
Response:
Byte 1 –Completion Code
Byte 2 –Default Restore Status:
OEM1 B3H Request:
Byte 1 ~16 – System GUID
Response:
Byte 1 – completion code Table Error! No text of specified style in document.-24. OEM2 Commands (NetFn 34H, 35h)
Command NetFN cmd Format
set web port number
oem2 02H Request:
Byte 1 – Https Port Number(Low Byte)
Byte 2 – Https Port Number(High Byte)
Byte 3 – Http Port Number(Low Byte)
Byte 4 – Http Port Number(High Byte)
Response:
Byte 1 – completion code
IPMI OEM Command List | 56
Get Restore Status

get web port number
oem2 03H Request:
Response:
Byte 1 – completion code
Byte 2 – Https Port Number(Low Byte)
Byte 3 – Https Port Number(High Byte)
Byte 4 – Http Port Number(Low Byte)
Byte 5 – Http Port Number(High Byte)
get board id oem2 11H Request:
Response:
Byte 1 – completion code
Byte 2 – Board ID
Set asset tag OEM2 12h Request:
Byte 1 - Length
Byte 2~11 - Data (Max Set Asset Tag Length - 0x0A )
Response:
Byte 1 - Completion Code
Byte 2 - Count Written
Set LAN Source OEM2 13h Request:
Byte1 – LAN Source
00h – Shared NIC
01h – Dedicated NIC
Response:
Byte 1 – completion code
Byte 2 – LAN Source Setting
IPMI OEM Command List | 57
01h ~ 04h

OEM2 14h Request:
Response:
Byte 1 – completion code
Byte 2 – Current LAN Source
00h – Shared NIC
01h – Dedicated NIC
oem2 16H Request:
Response:
Byte 1 – completion code
Byte 2 – FCB Fw Major number
Byte 3 – FCB Fw Minor number
oem2 61H Request:
Byte 1 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
[6:0] – Duty Cycle Setting. The rage is from 0 to 100, others are reserved.
Response:
Byte 1 – completion code
oem2 62H Request:
Response:
Byte 1 – completion code
Byte 2 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
[6:0] – Duty Cycle Setting. The rage is from 0 to 100, others are reserved.
IPMI OEM Command List | 58

oem2 63H Request:
Byte 1 – FSC Table Setting
Byte 1 – completion code
Byte 2 – FSC Table Setting
[7] – Enabled/Disabled FAN Table
[6:0] – Fan Table Setting(0-based)
Response:
Byte 1 – completion code
oem2 64H Request:
Response:
Byte 1 – completion code
Byte 2 – FSC Table Setting
[7] – Enabled/Disabled FAN Table
[6:0] – Fan Table Setting(0-based)
IPMI OEM Command List | 59

oem2 6aH Request:
Response:
Byte 1 – completion code
Byte 2 – FCB SKU Information
oem2 70H Request:
Response:
Byte 1 – completion code
Byte 2 – PIC model
Get PSU Mismatch and type
OEM2 B3H Request:
Response:
Byte 1 – completion code
Byte 2 – PSU mismatch
Byte 3 – PSU type
[7:4] PSU2 type
01h – 470 Watt
02h – 750 Watt
03h – 1100 Watt
04h – 1400 Watt
[3:0] PSU1 type
01h – 470 Watt
02h – 750 Watt
03h – 1100 Watt
04h – 1400 Watt
IPMI OEM Command List | 60

Table Error! No text of specified style in document.-25. Extended configurations
All strings are in P-String format.
Configuration ID = 02h, NIC
Attribute ID Size Description
NicSelection 1 1 Specifies the current mode of operation for the BMC network interface. 0: Shared NIC (default) 1: Dedicated NIC
SharedNICSelection 2 1 This parameter is only valid when Attribute ID 1 NICSelection parameter is set to 0h as Shared NIC.
IPMI OEM Command List | 61
Extended Configurations

or Dual Channel Single Package). When user attempts to set to a NIC value that is not supported on the platform, a completion code CCh should be returned to indicate an invalid data.
Configuration ID = 03h, SOL
Attribute ID Size Description
SOL Idle Timeout 1 2 byte1:2 - Define the inactivity timeout in minutes, 1-based, LSByte first. This parameter only applies to the IPMI over LAN session with SOL payload activated. 0h= session does not timeout and close due to inactivity. Default = 01h
Configuration ID = 04h, Security
Attribute ID Size Description
Service Disabled 1 1 Disable or enable services. This attribute takes precedence over the individual feature enabled/disabled. Once one service has been disabled, the BMC must not allow user to enable the corresponding feature and D5h completion code must be returned. For example, if HTTP/HTTPS is disabled, user must not abe able to enable the Web Server through Web Server
IPMI OEM Command List | 62
Telnet/SSH Redirect Enable

Configuration (Configuration ID 0Ch). In other words, Web can only be disabled or enabled when HTTP/HTTPS is enabled. [0] - all services except IPMI are disabled. This bit takes precedence over other bits. Default is 0. [1] - KVM/Virtual Storage, enabled by default. [2] - HTTP/HTTPS, enabled by default. [3] - SSH/Telnet, disabled by default.
2 1 Specifies the maximum number of allowed authentication failures. Setting this value to 0 will disable the lockout feature. Whenever this setting is modified, the number of authentication failure of each enabled user must be reset to 0. When an account Is locked out, the IPMI Messaging must be disabled on the LAN channel. See Get User Access command. Default = 00h (disable Lockout feature)
Lockout Window 3 2 Specifies the window, in second, during which if the consecutive maximum number of authentication failures is reached, the account should be disabled. Setting this value to 0 will disable the lockout feature.
IPMI OEM Command List | 63
Max Authentication Failures

Whenever this setting is modified, the number of authentication failure of each enabled user must be reset to 0. Default setting is 180 seconds.
Lockout Time 4 2 Specifies the time period an account should be disabled if the maximum number of authentication failures is reached. The unit is seconds. Setting this value to 0 will disable the lockout feature. Whenever this setting is modified, the number of authentication failures of each enabled user must be reset to 0. Default value is 3600 (1 hour).
Configuration ID = 05h, Account Status
Attribute ID Size Description
Number of User 1 1 Number of users created, including enabled and disabled users. The count Does not include USER ID1.
Number of Enabled User
2 1 Number of enabled users. R
User Name 3 1..17 Specify the user name in P- String format. Indexed by user ID.
IPMI OEM Command List | 64

Account Status 4 1 Status of the account. This is the supplement to the byte 3 of response data of Get User Access command. Indexed by user ID. 00h = status is unspecified 01h = user ID is enabled via Set User Password 02h = user ID is disabled via Set User Password 03h = user ID is lockout
Configuration ID = 06h, DNS
Attribute ID Size Description
DNS Dhcp Enable 1 1 Specifies that the DNS server IP addresses should be assigned from the DHCP server. 0: FALSE (default) 1: TRUE.
DNS Server1 2 4 Specifies the IP address for DNS server 1. This parameter is read-only if DNS Dhcp Enable and DHCP are enabled.
DNS Server2 3 4 Specifies the IP address for DNS server 2. This parameter is read-only if DNS Dhcp Enable and DHCP are enabled.
DNS Register BMC 4 1 Enables registering the BMC host name on the DNS server 0: FALSE (default) 1: TRUE.
DNS BMC Host Name
5 1..64 Specifies the DNS BMC host name. This parameter is read-only if DNS Register BMC is set to TRUE. At least one
IPMI OEM Command List | 65

character must be alphabetic. The default name is bmc- service_tag, where service_tag is the service tag number of the Dell server. For example: bmc- XG3487A.
DNS Domain Name Dhcp Enable
6 1 Specifies that the DNS domain name should be assigned from the DHCP server. 0: FALSE (default) 1: TRUE.
DNS Domain Name 7 1.256 The DNS domain name string. This parameter is read-only if DNS Domain Name Dhcp Enable is set to TRUE. Characters are restricted to alphanumeric, '-' and '.'. Default is “”
Configuration ID = 0Ch, WEB Server Configuration
Attribute ID Size Description
1 1 Disable or enable the BMC Web server. 0: FALSE 1: TRUE (default)
Max Web Sessions 2 1 The maximum number of simultaneous sessions allowed for this system. This field is READ-ONLY.
3 1 The number of current session for GUI on the system. This field is READ-ONLY.
4 4 The WEB communication idle timeout, in seconds. R/W
IPMI OEM Command List | 66
Web Server Enabled · Active Web Sessions · Web Server Timeout


Timeout range is 60 to 1920 seconds. A 0 specifies disabling the timeout feature. The default is 300.
HTTP Port Num 5 2 Specifies the port number to use for HTTP communication with the BMC. Default is 80.
HTTPS Port Num 6 2 Specifies the port number to use for HTTPS communication with the BMC. Default is 443.
Entity 1 1 Refer to Firmware Information configuration. R
Firmware Version 2 1..16 Refer to Firmware Information configuration. R
Branch 3 1..16 Refer to Firmware Information configuration. R
Build Information 4 1..16 Refer to Firmware Information configuration. R
Update Date / Time 5 3 Number of minutes from 0:00 hrs 1/1/08. LSbyte first (little endian)
Name 1 1..16 Specifies BMC model name, such as AST2050. R
Description 2 1..256 A text description of the type controller. R
IPMI OEM Command List | 67

Entity 3 1 Specifies the physical controller the image is associated with. 0: BMC 1: SYSTEM (BIOS) 2: PDB 3: FCB
Product Info 4 1..64 A text string that identifies the product. "Dell DCS Remote Management Controller" (default)
Firmware Version 5 1..16 A string containing the BMC firmware version. The firmware version is reading from IPMI Get Device ID command. The format of BMC FW Version string is ".", where major is one character and minor is two characters.
Branch 6 1..16 A string containing the firmware branch information.
Build Information 7 1..16 A string containing the firmware build number information. The string format is YYMMDD.
User Default Setting 8 1 This attribute enables user to customize various BMC settings and store as user default. It also allows user to erase current settings and restore back to previously set user default settings. User default settings include all write-able settings in Extended Configuration Parameters, IPMI User Account
IPMI OEM Command List | 68

Settings, and IPMI LAN Configuration Parameters.
0h – Set as User Default
1h – Restore User Default Configuration ID = 10h, Firmware Update
Attribute ID Size Description
1 1 Allow firmware update via TFTP server. R/W
Protocol 2 1 Specified supported protocols. [7:3] - reserved [2] - HTTP [1] - FTP [0] - TFTP
URI 3 1..256 The URI of the image file. R/W
Connection Retry 4 1 Specify the number of retries for connecting to TFTP server. A zero value means the BMC does not attempt to retry connect to TFTP server.
Retry Interval 5 1 Define the retry interval in 5 seconds increaments. R/W
Delay Time 6 1 Define the delay time for connecting to TFTP server. The time is specified in seconds. 00h: BMC connects to TFTP server immediately. FFh: random between 5 and 10 seconds.
IPMI OEM Command List | 69
Remote Update Enable

Configuration ID = 11h, Power Management
Attribute ID Size Description
1 1 Specify the use of power management method. Bit 7: Enable DPNM power management 1b = enable DPNM 0b = disable DPNM Bit 6:0: reserved
Power Staggering AC Recovery
2 1 This parameter is only effective if the Power Policy is not set to always off. 0x00 : Immediate Power On (No Delay) : Default 0x01 : Auto (Random), the auto generated delay time must be in the range of Minimum Power On Delay and Maximum Power On Delay. 0x02 : User Defined, the user defined delay time must be in the range of Minimum Power On Delay and Maximum Power On Delay.
Power On Delay 3 2 Defines the time to delay power on the system after AC recovered.
Minimum Power On Delay
4 2 Specifies the minimum power on delay time when AC is restored. This should not be less than the time BMC startup time.
Maximum Power On Delay
5 2 Specifies the maximum power on delay time when AC is restored. The number must large than Minimum Power On Delay.
IPMI OEM Command List | 70
Power Management Enable

SSH/Telnet Enable and Disable
Configuration ID = 04h, Security
Attribute ID Size Description
1 1 Disables or enables services. This attribute takes precedence over the individual feature enabled/disabled. Once one service has been disabled, the BMC must not allow users to enable the corresponding feature and D5h completion code must be returned. For example, if HTTP/HTTPS is disabled, user must not be able to enable the Web Server through Web Server Configuration (Configuration ID 0Ch). In other words, Web can only be disabled or enabled when HTTP/HTTPS is enabled. [0] - all services except IPMI are disabled. This bit takes precedence over other bits. Default is 0. [1] - KVM/Virtual Storage, enabled by default. [2] - HTTP/HTTPS, enabled by default. [3] - SSH/Telnet, disabled by default.
Example:
Get SSH/Telnet enable status:
1 Reserved Extended Configuration
ipmitool raw 0x30 0x01
Service Disabled · Appendix | 71

2 Get Extended Configuration
ipmitool raw 0x30 0x02 0x01 0x04 0x01 0x00 0x00 0x00 0xFF
Set SSH/Telnet Enable:
1 Reserved Extended Configuration
ipmitool raw 0x30 0x01
ipmitool raw 0x30 0x03 0x02 0x04 0x01 0x00 0x00 0x00 0x01 0x00 (set SSH/Telnet enable)
Configuration ID = 03h, SOL
Attribute ID Size Description
Example:
Get SSH/Telnet Redirect enable status:
1 Reserved Extended Configuration
ipmitool raw 0x30 0x01
2 Get Extended Configuration
Ipmitool raw 0x30 0x02 0x01 0x03 0x02 0x00 0x00 0x00 0xFF
2 Enable SSH/Telnet · Telnet/SSH Redirect Enable · Appendix 72

Set SSH/Telnet SOL Redirect enable:
1 Reserved Extended Configuration
ipmitool raw 0x30 0x01
2 Enable SSH/Telnet SOL redirect.
ipmitool raw 0x30 0x03 0x02 0x03 0x02 0x00 0x00 0x00 0x01 0x01 (set 1 to enable)
User can use LAN configuration command parameter 14H to Set or Get VLAN ID. More VLAN information, please refer to “IPMI SPEC v2.0 errata revision 4”.
Commands NetFn CMD O/M Supported
Set LAN Configuration Parameters
Transport 01h M Yes
Transport 02h M Yes
LAN configuration Parameter 14H:
Parameter # Parameter Data
802.1q VLAN ID (12-bit)
[7:0] - Least significant 8-bits of the VLAN ID. 00h if VLAN ID not used.
[7] - VLAN ID enable.
0b = disabled, 1b = enabled. If enabled, the BMC will only accept packets for this channel if they have 802.1q fields and their

VLAN ID matches the VLAN ID value given in this parameter.
[6:4] - reserved
[3:0] - most significant four bits of the VLAN ID
Example:
1 Get LAN Configuration Parameter command:
ipmitool raw 0xC0 0x02 0x01 0x14 0x00 0x00
2 Set LAN Configuration Parameter command:
ipmitool raw 0xC0 0x01 0x01 0x14 0x01 0x80
Get Device ID command can get BMC version Info in response date byte4, 5. More detail about this command please refers to “IPMI SPEC v2.0 errata revision 4” chapter 20.1.
Response Date Data field
Byte 1 Completion Code
Byte 2 Device ID.
Byte 3 Device Revision
[7] 1 = device provides Device SDRs
0 = device does not provide Device SDRs
[6:4] reserved. Return as 0.
[3:0] Device Revision, binary encoded.
BMC Version Info · Appendix 74

evice available:
: 0=normal ope
itory update or ware / SDR
s.
itory updates c command and c
tiated by issuin ompletion code
e.]
nary encoded.
ware Revision.
ed.
Example:
command:
0 0x25 0x01 0 00 0x00
2 0xbf 0xa9 0x
19 0x00 0x3b 0

T B
The BIOS enab BMC early in P
bles the system POST.
m interface to th
he BMC and lo
ogs this event to
User can find t
on in event rec
6 as following t
table:
D
0x04 (IPMI 1.5
Example:
ue SEL list com
ty ID is 9
mitool sel get 9
on is V 1.1