Culligan ® Sulfur-Cleer ™ Automatic Water Filter Owners Guide.
Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations.
Table of Contents iii S p e c i fi c a t i o n s ................................................1 I n t r o d u c t i o n ..................................................2 O p e r a t i n g C o n d i t i o n s .....................................
This page intentionally left blank. iv.
Specifications Culligan ® 10” Sulfur-Cleer ™ Filter with Fiberglass Tank Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1” 5-cycle reinforced thermoplastic T i m e r .....................................
Introduction Operation Step 1. Service Cycle In the service cycle, raw water enters the inlet port of the media tank. The oxidation process begins. This air/water contact oxidizes the iron and hydrogen sulfide in the water. Oxidized iron particles are trapped by the filter bed as the water passes through.
Step 3. Filter Tank Operation - Backwash Cycle Reversing the flow of water through the filter bed and backwashing dirty water to the drain cleans the filter bed.
The concentration limits listed below reflect the minimum or maximum individual limit that each contaminant was tested for separately without any interference of other contaminants in the influent water.
Fam ilia riz atio n Power Loss The Circuit b oard is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost.
Modes of Operation Manual Regeneration Pressing and holding the regen button for 5 seconds will initiate an immediate regeneration. The beeper is to give one beep at the start of manual regeneration (when the motor starts to turn).
7 The circuit board controls all of the filter functions. These settings are programmed at the time of installation. The following is a list of all the microprocessor functions, in the event that any of the settings need to be adjusted. Display Icons The display is to be backlit and have the icons as shown.
8 • Time of Regeneration - This setting is used to program the time at which a regeneration is to occur in the delay mode. The display will first show “tor” for two seconds. After “tor” is shown the display will then show the default of 2:00 AM (or the current programmed time of regeneration if already set).
9 If any of the days were set to “yes”, the display will show “SETDAY” followed by “SUN”. This selects the current day of the week. The “+” or “-“ key toggles through the days of the week and pressing the “STATUS” key saves the setting and advances to the next programming step.
Programming (cont.) • Filter Media Life - This setting is available only with flow meter attached. It enables or disables an alert code ( CHANGE MEDIA ) that indicates the end of life for the filter media.
Programming (cont.) • Auxiliary Output #1 “ON” Time - This setting is used to control the “ON” time of the aux1 output which turns on the compressor and vent solenoid. The aux 1 output should act independently, however, it should never be activated during a regeneration.
12 The statistical functions are reached by pressing the “Information” key. Repetitive presses of the “Statistics” key will cycle through the standard statistics mode until cycled back to time of day display.
When and How to Bypass Your Water Conditioner 13 Normally, all water except outside lines passes through the water conditioner. There are times when the water conditioner should be bypassed, using the push-button Cul-Flo-Valv ® Bypass, or a 3-way bypass valve.
Regeneration with Bleach When bleach is used to regenerate the Sulfur-Cleer ™ , Culligan strongly recommends the dealer set-up a service contract with the customer to initiate the regeneration when required.
15 Things to Check Before You Call for Service If you unexpectedly experience problem water, make these simple checks before calling your Culligan dealer.
16 Preventative Maintenance The Culligan Sulfur-Cleer ™ water filter has been designed to provide a good, consistent service life. Because of the nature of problem water, we recommend that the local Culligan dealer provide regular maintenance/service contracts for the proper operation of your systems.
17 Troubleshooting Guide Complaint Problem Cause Solution Iron bleed- through or staining. A. Inadequate backwash of filter 1. Plugged drain line flow control 1. Call your Culligan dealer for service. 2. Insufficient water supply from well. 2. Check for minimum specified flow and pressure requirements of filter system.
Troubleshooting Guide (cont.) 18 Complaint Problem Cause Solution Water leaking from relief valve. A. Dirt lodged under seat of valve. 1. Pressure has exceeded rating on relief valve and caused valve to open 1. Call your Culligan dealer for service. B.
19 Troubleshooting Guide (cont.) Complaint Problem Cause Solution Water is running to drain continuously. A. Control valve is stuck in regeneration cycle. 1. Electrical service to control(s) has been interrupted. 1. Assure continuous electrical service is available.
20 Performance Data Sheet Culligan ® Sulfur-Cleer ™ Water Filter Important Notice — Read this data sheet and compare the capabilities of the unit to your actual water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing a water treatment unit.
21 Records and Data Important Data on Your Water Filter It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer.
Culligan Limited Warranty 22 Culligan ® Sulfur-Cleer ™ Automatic Water Filters You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan In.
23 You Get Your Water Expert, The Culligan Man ® We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over seventy years, delivering dependable service all along.
An important point after buying a device Culligan Sulfur-Cleer (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Culligan Sulfur-Cleer yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Culligan Sulfur-Cleer - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Culligan Sulfur-Cleer you will learn all the available features of the product, as well as information on its operation. The information that you get Culligan Sulfur-Cleer will certainly help you make a decision on the purchase.
If you already are a holder of Culligan Sulfur-Cleer, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Culligan Sulfur-Cleer.
However, one of the most important roles played by the user manual is to help in solving problems with Culligan Sulfur-Cleer. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Culligan Sulfur-Cleer along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center