OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501B FOR MO DULES WITH SERIAL NUMBERS: 3118A -00101 A ND A BOVE A gilent Part No. 60501-90009 Printed in U.
DECLA RA TION OF CONFORMI TY according to IS O/IEC G uide 22 and E N 45014 Manufacturer’s Name : Agilent Tec hnologies Manuf acturer’s A ddress: New Jersey Divi sion 140 Green Pond Road Rock away , NJ 07866 U.
1 150-Watt Module About This Manual This m anual provides in form ation for t he Ag ilent 60501B 150- Watt Electron ic Load Modul e. It is desig ned as a supplem ent to the A gilent 6050A /6051A Mu ltiple Input Mainf rame Electron ic Load Operating Man ual (part nu mber 06050- 90001).
2 Table 60501-1. Specification and Supplemental Characteristics SPECIFICA TIO NS DC Input Rating: Current: 0 to 30 A Voltage : 3 to 60 V (min imu m dc operat ion from 0 to 2 V for 0 t o 30 A) Pow er: 150 W at 40 ° C (derated to 112 W at 55 ° C) A . OPERA TING CHARA CTERISTICS B.
3 Table 60501-1 Specifications and Supplemental Characteristics (continued) Transient Operat ion: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency A ccuracy : 3% Duty Cy cle Range: 3% to 97% (0.
4 Table 60501-1 Specifications and Supplemental Characteristics (continued) External A nalog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db freque ncy ) A ccuracy: ± 4.5% ± 40 m A (0 t o 3 A rang e) ± 4.5% ± 130 m A (0 to 30 A range) ± 0.
5 Table 60501-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 30 A Range Step 3 A Range Step Transition T ime 1 0.5 A/m s 0.05 A/s 8.0 ms 2 1.2 A/m s 0.12 A/s 3.2 ms 3 2.5 A/m s 0.25 A/m s 1.6 ms 4 5 A/m s 0.5 A/m s 800 µ s 5 12 A/m s 1.
6 Table 60501-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of fin al value (in CC and CR m odes w hen connected to pow er supplies with voltage rise times of greater than 500 µ s). Programmable Shor t Circuit: 0.
7 Table 60501-2. Programming Ranges (continued) Transient O peration Set Frequency FREQ value " T RAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cy cle (shif t) DCYCLE v alue "TRAN: DCYC va lue" 3-97% (0.25 Hz- 1 kHz) 6-94% (1 k Hz-10 kH z) *S et Puls e Width "TRAN:TWID valu e" 0.
8 Table 60501-4. Calibration Info rmation Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High C urrent R ange Hi_cu rr_rng 30 5 V/31 A 100 A High C urrent Of fset Hi_curr_off set 0.013 Low Cu rrent Ran ge Lo_curr_rn g 3 5 V/10 A 15 A Low Curren t Off set L o_curr_off set 0.
9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative.
An important point after buying a device Agilent Technologies 60501B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Agilent Technologies 60501B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Agilent Technologies 60501B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Agilent Technologies 60501B you will learn all the available features of the product, as well as information on its operation. The information that you get Agilent Technologies 60501B will certainly help you make a decision on the purchase.
If you already are a holder of Agilent Technologies 60501B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Agilent Technologies 60501B.
However, one of the most important roles played by the user manual is to help in solving problems with Agilent Technologies 60501B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Agilent Technologies 60501B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center