HALO

D E S C R I P T I O N

Catalog # Type

A low wattage metal halide track fixture utilizing 70 watt T4.5 ceramic metal halide capsules providing compact size and adjustable optics. Ideal for accent and display lighting applications. This fixture provides an adjustable beam of light with high efficiency, good color rendering and long life.

Project

Comments

Date

Prepared by

S P E C I F I C A T I O N F E A T U R E S

Cooper Lighting LF5300 — Project diagram (page 1)
Fig. 1 · Project

A ...Electrical Quick Lock Adapter - Power-Trac Polycarbonate housing. Attaches electrically and mechanically anywhere along track.

be turned off during lamp replacement on individual lampholders.

infinite beam adjustment from spot to flood. Detents align with beam angle icons to allow repeatability at spot, narrow flood and flood positions.

D ...Lamp Housing Injection molded lamp housing has an integral segmented reflector and adjustable light center optics allowing the light beam to be adjusted from spot to flood. Lamp housing adjusts ±90° providing full aiming adjustment and eliminates the "dead zone" found with other fixture designs.

A 1 ...Electrical Quick Lock Adapter - Flexible Track Die cast housing. Attaches electrically and mechanically anywhere along track.

G ...Lens Removable front bezel with glass lens provides lamp containment. Front bezel accepts L200 media including color filters and beam modifying lens. Replace glass lens with one filter or lens. Remove glare shield to accept second filter or lens.

A 2 ...Electrical Quick Lock Adapter - Architectural Track Polycarbonate housing with integral fuse and On-Off switch. Attaches electrically and mechanically anywhere along track.

L5300 LA5300

E ...Tilt and Rotation Locks Tilt and rotation locking are easily accomplished by using a 9/64" Allen wrench (supplied by others). The locking mechanisms firmly hold fixture aim even during relamping.

H ...Glare Shield Glare shield provides additional cutoff. Removes easily for lamp replacement.

LF5300

B ...Ballast Housing Injection molded housing incorporates the lamp control circuit.

70W Accent

Labels UL/cUL listed for use with Halo Track systems. EMI/RFI complies with FCC 18C, non-consumer limits.

MiniLUME Adjustable

C ... Switch On-off switch allows power to

F ... Beam Focus Knob Knob rotates 90° providing

Ceramic Metal Halide

A1

A

B

E

F

D

Energy Data

H

G

A2

Input Power77W Power Factor: >0.95 Input Current: 0.64A max. Harmonic Distortion: <10%

E

O R D E R I N G I N F O R M A T I O N : S A M P L E N U M B E R : L 5 3 0 0 7 0 E S C P L

Accessories Lampholder

Ballast

Reflector

Finish

Lamp

Style

70E

L5300= For Halo

70E =70 Watt Electronic Ballast

P=White MB=Black SL=Silver M B/GY=Black w

Power Trac and Lazer Track LA5300= For Halo

Clear Reflector Finish CG= Commercial

Color Filters or Beam Modifying Lenses

Architectural Track LF5300= For Halo

Gray Knob & Trim Ring P/GY=White w Gray

Knob & Trim Ring

ADV072006

Show 19 more labels / short text on this page
® · 5-1/4” [133mm] · 5-1/8” [130mm] · 1-5/8” [41mm] · 10-3/4” [273mm] · 5-1/4” [133mm] · 70W Electronic Ballast · 5-1/4” [133mm] · 5-1/4” [133mm] · 6-3/4” [171mm] · (Blank)=Open · SC = Specular · L=Lamp · L200 Series= · Included · Back CB=Closed · Back · Gold Reflector Finish · Flexible Track
Page 2 of the Cooper Lighting LF5300 user manual — L 5 3 0 0
Page 2 · click to enlarge
Page 2

L 5 3 0 0

PHOTOMETRICS

L530070E at Spot Position Report No. 12125.0

L530070E at Medium Flood Socket Position Report No. 12126.0

L5300 at Flood Socket Position Report No. 12127

Cooper Lighting LF5300 — L 5 3 0 0 diagram (page 2)
Fig. 2

Candelas at Nadir Deg Candela 0 44514 5 32693 15 3657 25 829 35 346 45 102 55 14 65 8 75 2 85 0 90 0

Candelas at Nadir Deg Candela 0 16318 5 15252 15 5382 25 1425 35 362 45 59 55 14 65 9 75 0 85 0 90 0

Cooper Lighting LF5300 — L 5 3 0 0 diagram (page 2)
Fig. 3

Candelas at Nadir Deg Candela 0 6500 5 6399 15 5058 25 2088 35 390 45 47 55 21 65 17 75 0 85 0 90 0

0° Aiming Angle 30° Aiming Angle 30° Aiming Angle 60° Aiming Angle Lamp Horizontal Footcandles Horizontal Footcandles Vertical Footcandles Vertical Footcandlesi

CMH70/TC/U/830G8.5 Lumens6200 Lumens

D FC L W 5.0' 1781 1.3 1.3 7.5' 791 2.0 2.0 10.0' 445 2.7 2.7 12.5' 285 3.4 3.4

D FC L W CB 5.0' 1157 1.7 1.5 2.9 7.5' 514 2.5 2.2 4.3 10.0' 289 3.4 3.0 5.8 12.5' 185 4.2 3.7 7.2

D FC L W CB 3.0' 685 2.6 1.5 5.2 4.0' 385 3.5 2.0 6.9 5.0' 247 4.3 2.5 8.7 6.0' 171 5.2 3.0 10.4

D FC L W CB 3.0' 3213 1.0 0.9 1.7 4.0' 1807 1.3 1.2 2.3 5.0' 1157 1.7 1.5 2.9 6.0' 803 2.0 1.8 3.5

SettingSpot

Report No.: BAL12125

CMH70/TC/U/830G8.5 Lumens6200 Lumens

D FC L W 5.0' 653 2.1 2.1 7.5' 290 3.2 3.2 10.0' 163 4.3 4.3 12.5' 104 5.3 5.3

D FC L W CB 5.0' 452 2.6 2.3 2.9 7.5' 201 3.9 3.5 4.3 10.0' 113 5.2 4.7 5.8 12.5' 72 6.5 5.9 7.2

D FC L W CB 3.0' 326 3.3 2.1 5.2 4.0' 183 4.3 2.8 6.9 5.0' 117 5.4 3.5 8.7 6.0' 82 6.5 4.2 10.4

D FC L W CB 3.0' 1255 1.6 1.4 1.7 4.0' 706 2.1 1.9 2.3 5.0' 452 2.6 2.3 2.9 6.0' 314 3.1 2.8 3.5

SettingMedium Flood

Report No.: BAL12126

CMH70/TC/U/830G8.5 Lumens6200 Lumens

D FC L W 5.0' 260 3.4 3.4 7.5' 116 5,1 5.1 10.0' 65 6.8 6.8 12.5' 42 8.5 8.5

D FC L W CB 5.0' 188 3.8 3.6 2.9 7.5' 84 5.7 5.5 4.3 10.0' 47 7.5 7.3 5.8 12.5' 30 9.4 9.1 7.2

D FC L W CB 3.0' 193 3.2 2.7 5.2 4.0' 108 4.3 3.6 6.9 5.0' 69 5.3 4.5 8.7 6.0' 48 6.4 5.4 10.4

D FC L W CB 3.0' 523 2.3 2.2 1.7 4.0' 294 3.0 2.9 2.3 5.0' 188 3.8 3.6 2.9 6.0' 131 4.5 4.4 3.5

SettingFlood

Report No.: BAL12127

Beam spread is to 50% center beam candlepower (CBCP.) D=Distance in feet to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L =Effective Visual Beam length in feet (50% of maximum footcandle level.) W=Effective Visual Beam width in feet (50% of maximum footcandle level.) CB=Distance in feet across or down to center beam location.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADV040833

Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049

0˚ 15˚ 30˚ · 0˚ 15˚ 30˚ · 0˚ 15˚ 30˚

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Cooper Lighting LF5300

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Cooper Lighting LF5300

Be the first to ask — other owners or our team will answer.

Original document

Cooper Lighting LF5300 manual PDF

2 pages·117 KB·Indoor Furnishings·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…