Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4”
Rev. No. Released Date Description
Rev.B Beta Apr. 16, 2009 First Release


Rev. B6 May 27, 2010 Page 33 Baud Rate – Add 57.6K BPS and 115.2K BPS.
Rev. No. Released Date Description
Rev. B8 Sep 29 , 2010
Rev. C3 Jul 22, 2011
Rev. C5 Jan 02, 2012

Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of
merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental
consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains
proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,
reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written
permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the
product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different
warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident
or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized
representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied
software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but
not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA
KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)
AS/NZS CISPR 22:2009 Class B
procedures to return Cino for inspection.
© Copyright PC Worth Int’l Co., Ltd
© Copyright Cino Group
Warranty
FCC part 15B

LED Eye Safety IEC62471 Exempt group
Laser Eye Safety IEC60825-1 Class 1



FuzzyScan imagers support PS/2(DOS/V) Keyboard
Wedge, RS-232 Serial, and USB interfaces. Please
choose your desired interface cable, then plug it into the
cable interface port of the imager and connect it to the
host. If you would like to remove the cable, please
straighten one end of a paper clip, then insert it into the
cable release hole to pull out the cable.




Thank you for choosing Cino FuzzyScan Imager. All
FuzzyScan imagers deliver world-class performance for a
broad range of applications to unleash your productivity. This
document provides an easy reference for installation and
operation purposes. A complete documentation is provided
by the FuzzyScan Programming Manual available at



F700 & L700 Series
F600 & L600 Series

You can enhance productivity of your workforce by using
various accessories to fulfill a wide variety of application
A stylish Universal Holder is designed for
storing your imager when not in use. It
serves to protect the imager from
lens-scratched or falling. Moreover, its
artistic-design enhances the entire value
A SmartStand is specifically designed
for hand-free applications to maximize
user’s comfort and productivity. You
can adjust the scanner holder to
desired position for optimized
Thanks to the auto-sense design, the
imager is capable of switching
between presentation scanning and
Please note that the SmartStand is
not applicable for F400 Series imager.
while working with SmartStand.
of the imager.
scanning.


demand.

The System Command is the highest level bar code
command which directs FuzzyScan to perform immediate
operations, such as entering programming mode
(PROGRAM), exiting programming mode (EXIT), listing
system information (SYSLIST), recovering to factory
preset configurations (M_DEFAULT) and so on. Please
complete the operations. User must wait for the
The Family Code is scanned to select the user desired
programming family. FuzzyScan has already provided
more than one hundred programming families to meet any
The Option Codes is a set of bar code commands
represented by “0–9”, “A–F” and finishing selection (FIN).
For most setting, you must select at least one option code
following the family code selection to set the desired
completion beeps before scanning another bar code.
parameter for the selected programming family.
System Command System Command System Command System Command
specific requirements.
Option Code Option Code Option Code Option Code
Family Code Family Code Family Code Family Code
The FuzzyScan bar code commands are specially designed
Proprietary bar code labels which allow you to set the
FuzzyScan internal programming parameters. There are
System Command, Family Code and Option Code for
Each programmable family and bar code command label is
listed on the same page with major system commands. The
detailed explanations and special programming flowchart are
printed on facing or following pages. You can read the
A supplemental bar code command menu incorporates the
bar code command labels of System Command and Option
Code. As you set the FuzzyScan, open the bar code
command menu to find the option code page. You may scan
the desired family code and option code to set FuzzyScan. If
you want to change the programming family for multiple
settings, you need only turn over the programming page to
explanation and set the FuzzyScan concurrently.
find next desired programming family.
programming purpose.

If the programming family must take multiple scans
selection, cycling scan selection, or dual level selection
procedures, the family of the programming menu will be
marked with the matched representing symbol of
Programming Category (P.C.) in bold font listed in the
following table. You can easily find the bold mark in the
programming menu, and refer to their flowcharts for details.
Before setting the FuzzyScan, please also refer to the
“Beeping Indications” listed in Appendix to understand the
details of programming beeping indications. It will be very
helpful for you to know the existing status while you are
P.C. Programming Category
( ) Necessary Option Code
[ ] Selectable Option Code
Conventions of Pr Conventions of Pr Conventions of Pr Conventions of Programming Menu ogramming Menu ogramming Menu ogramming Menu
Factory Default Value
programming the FuzzyScan.
As you scan the bar code command to select the desired
parameters, information about the final selected parameters
represented by the bar code commands are stored in the
FuzzyScan’s internal Flash Memory ASIC or non-volatile
memory. If you turn off the unit, the Flash Memory ASIC or
non-volatile memory retains all programming options. You
need not re-program the FuzzyScan if you want to keep the
The programming procedures of FuzzyScan are designed
as simple as possible for ease of setting. Most
programming families take the Single Scan Selection
programming procedure. But several programming families
have more complex and flexible programmable options,
and you must take Multiple Scans Selection, Cycling
Scan Selection or Dual Level Selection to complete their
programming procedures. Each kind of programming
procedure is listed in the following pages for your reference.
Please give careful attention to become familiar with each
existing configurations in the next power on.
Programming Procedures Programming Procedures Programming Procedures Programming Procedures
programming procedure.
Conventions Descriptions

revision number to host via selected host interface,
FuzzyScan will list the product information and
parameters into factory preset configurations,
System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default
FuzzyScan will recover all programmable
then issue the completion beeping.
then issue the completion beeping.
“ SYSLIST ”
Please note that the FuzzyScan will take 3-4 seconds to
store parameters in internal Flash Memory ASIC or
non-volatile memory after you scan the “END”. Please
don’t turn off the power before the completion beeping. It
parameters in Flash Memory ASIC or non-volatile memory,
FuzzyScan will exit programming mode, and store all
and inhibit all non-programming functions.
FuzzyScan will enter programming mode,
then issue the completion beeping.
may destroy all configured parameters.
Program & End Program & End Program & End Program & End

Enter programming mode.
option codes to select
option code selection.
Exit programming mode.
desired parameters.
programming families.
Want to select another
Select one of desired
Multiple scans selection Multiple scans selection Multiple scans selection Multiple scans selection
One of Family Codes
Enter programming mode.
Select one option code of
Exit programming mode.
programming families.
Want to select another
Select one of desired
desired parameter.
Single scan selection Single scan selection Single scan selection Single scan selection
One of Option Codes
One of Family Codes

Select several option codes
option codes of desired
Enter programming mode.
option code selection.
of desired parameters.
Exit programming mode.
programming families.
Want to select another
Select one of desired
parameters.
One of Family Codes
(2nd) Scan One or
Dual lev Dual lev Dual lev Dual level selection el selection el selection el selection
(1st) Scan
Enter programming mode.
Finish cycling selection.
several option codes of
Exit programming mode.
programming families.
Cycling select one or
Want to select another
Select one of desired
scans selection.
One of Family Codes
One of Option Codes
Cycling scan selection Cycling scan selection Cycling scan selection Cycling scan selection
Scan “FIN”

02 06 08 09 10 13 14 17 18 19
IBM PS/2, 25-30 series keyboard wedge interface
PS/2 (DOS/V) direct link (keyboard replacement)
PS/2 (DOS/V) keyboard wedge standard mode
PS/2 (DOS/V) keyboard wedge turbo mode
Standard/TTL RS-232 peer-to-peer serial
USB HID standard mode
USB Com Port Emulation
USB HID turbo mode
MS
MS
MS
MS
MS
MS
MS
MS
MS
Wand emulation · Laser emulation · Host Interface Selection

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 26
♦ User Defined Symbol ID ♦
UCC Coupon Extended Code (Default=Z)
Standard/Industrial 2 of 5 (default=I)
PDF417/Micro PDF417 (default=V)
German Postal Code (default=M)
China Postal Code (default=L)
Code 39/Code 32 (default=G)
Interleaved 2 of 5 (default=J)
Trioptic Code 39 (Default=W)
Korea Post Code (default =a)
Codabar/NW-7 (default=D)
Matrix 2 of 5 (default=K)
MSI/Plessey (default=R)
GS1 DataBar (default=X)
Codablock F (default=Y)
UK/Plessey (default=S)
DS Code 128 (default=B)
GS1-128 (default=C)
Code 93 (default=H)
Code 11 (default=P)
UPC-A (default=A)
EAN-13 (default=F)
Telepen (default=T)
UPC-E (default=E)
IATA (default=O)
EAN-8 (default=N)

0 1 2 3 4 5 6
♦ Symbology ID Transmission ♦
Enable both prefix and suffix CINO symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
Enable prefix CINO symbology ID transmission
Enable suffix CINO symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Disable symbology ID transmission
Symbology ID Transmission

If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add
00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.
Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.
♦ Readable Bar Code Setting ♦
the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.
Standard/Industrial 2 of 5
GS1 DataBar (RSS-14) *
Interleaved 2 of 5 *
Matrix 2 of 5
UPC-A *
UPC-E *
EAN-8 *
IATA
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
Remember to scan “FIN” to terminate
“ Auto ”, FuzzyScan will terminate this
this selection. But if you select the
selection automatically.


0 1 2 3 4 5 6 7 8 9 A
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format
♦ Code 39/Code 32 Setting ♦
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Code 39 Family Setting
Trioptic Code 39 Setting
Code 39 Min. Length
Code 39 Max. Length

Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.
0 1 2 3
Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.
Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.
♦ Code 39 Setting ♦
The scanner offers four levels of decode security for Code39 bar codes:
Code 39 Security Level
Code 39 Security Level

0 1 2 3 4 5 6 7 8 9 A
D
E
0 1 2 3 4 5 6
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Codabar/NW-7 Setting ♦
Enable ABCD/ABCD start/stop symbol transmission
Enable ABCD/TN*E start/stop symbol transmission
Enable abcd/abcd start/stop symbol transmission
Enable abcd/tn*e start/stop symbol transmission
Disable start/stop symbol transmission
Select Codabar standard format
Disable check digit transmission
Disable check digit verification
Enable check digit transmission
Enable check digit verification
Runes (Modulus 10/weight 2)
Select Codabar ABC format
Select Codabar CLSI format
this selection automatically.
Select Codabar CX format
7 check DR Weight Modulus 11
MS Default (04)
Codabar Check Digit Settings
Codabar Min. Length

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Codabar/NW-7 Setting ♦
this selection automatically.
MS Default (98)
Codabar Max. Length
(2 digits) · 98-Minimum


When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric

UPC-A 12 - 1 - 1 + 2 + 5 + 1 0 UPC-E 8 - 1 - 1 + 2 + 5 + 1 + 4
EAN-13 13 - 1 NC + 2 + 5 NC 0 EAN-8 8 - 1 NC + 2 + 5 NC + 5
0 1 2 3 4 5 6 7 8 9 A
UPC-E & EAN-8 Expansion : Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option.
♦ UPC-A & UPC-E Setting ♦
UPC-A Standardization : Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
system, UPC-A check digit transmission.
UPC Family Setting · WPC Selection

Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,
B
D
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6
Only available for UPC-A & EAN-13
♦ UPC-A & UPC-E Setting ♦
Disable force supplement digits output
Select UPC without supplement digits
Select UPC with only 2 supplement digits
Select UPC with only 5 supplement digits
UPC Family Addenda Separator Off
Select UPC with 2/5 supplement digits
Enable force supplement digits output
UPC Family Addenda Separator On
security level may significantly impair the decoding ability of the scanner.
The scanner offers three levels of decode security for UPC/EAN bar codes:
low contrast or damage barcode labels.
increase the misread.
UPC/EAN Security Level

The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,
B
D
0 1 2 3 4 5 6 7 8 9 A
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6
♦ EAN Setting, EAN Supplement Setting ♦
Disable ISBN/ISSN Conversion reading check
Enable EAN-13 check digit transmission
Enable ISBN/ISSN Conversion reading check
Enable EAN-8 check digit transmission
Disable force supplement digits output
Select EAN without supplement digits
Disable EAN-13 check digit transmission
Select EAN with only 2 supplement digits
Select EAN with only 5 supplement digits
Disable EAN-8 check digit transmission
Select EAN with 2/5 supplement digits
Enable force supplement digits output
EAN Addenda Separator Off
Disable EAN-8 expansion
EAN Addenda Separator On
low contrast or damage barcode labels.

Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
0 1 2 3 4 5 6 7
Only available for UPC-A & EAN-13
♦ EAN Security Level Setting ♦
supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.
Disable all specific prefix supplement digital output
Enable all specific prefix supplement digital output
digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.
Enable 978/979 Supplement Digit Output
Enable 378/379 Supplement Digit Output
Enable 414/419 Supplement Digit Output
Enable 434/439 Supplement Digit Output
Enable 491 Supplement Digit Output
Enable 977 Supplement Digit Output
security level may significantly impair the decoding ability of the scanner.
The scanner offers three levels of decode security for UPC/EAN bar codes:
increase the misread.
UPC/EAN Security Level
EAN Supplement Control

When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128
Enable UCC Coupon Extended Code 0 1
♦ UCC Coupon Extended Code Setting ♦
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
SS Disable UCC Coupon Extended Code
UCC Coupon Extended Code
UCC Coupon Extended Code

0 1 2 3 4 5 6 7 8 9 A
0 1 2 3 4 5 6 7 8
♦ IATA & Interleaved 2 of 5 Setting ♦
Enable CPN, Airline and S/N check digit verification
Select 15-digit fixed length IATA checking
Select Interleaved 2 of 5 as primary format
Select German Postal Code as primary format
Disable start/stop symbol transmission
Enable S/N checking digit verification only
Enable CPN checking digit verification only
Enable check digit automatic verification
Enable start/stop symbol transmission
Disable check digit transmission
Disable check digit transmission
Disable check digit verification
Enable check digit transmission
Enable check digit transmission
Enable Interleaved 2 of 5
Select variable length IATA
Disable Interleaved 2 of 5
Validate OPCC check digit
Validate USS check digit
No check character
Interleaved 2 of 5 Setting
Disable IATA · Enable IATA · IATA Setting

For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable
0 1 2 3 4 5 6 7 8 9
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Code 25 Family Setting ♦
Disable Standard/Industrial 2 of 5
Disable check digit verification
Disable check digit transmission
Enable check digit transmission
Enable Standard/Industrial 2 of 5
Disable China Postal Code
Enable check digit verification
this selection automatically.
this selection automatically.
Enable China Postal Code
Disable Matrix 2 of 5
Enable Matrix 2 of 5
MS Default (04)
MS Default (98)
length of Code 25 will increase the possibility of reading error.
Code 25 Family Min. Length
Code 25 Family Max. Length


Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Code 11 & Code 93 Setting ♦
Code 11 Min. Length
Code 11 Max. Length
Code 93 Min. Length
Code 93 Max. Length
Code 93 Setting · Code 11 Setting

0 1 2 3 4 5 6
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ MSI/Plessey Setting ♦
Disable check digit transmission
Enable check digit transmission
Select MOD 10 check digit
Select MOD 10-10 check digit
Select MOD 11-10 check digit
this selection automatically.
this selection automatically.
MS Default (04)
MS Default (98)
MSI/Plessey Min. Length
MSI/Plessey Max. Length

0 1 2 3 4 5
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Code 128 & UCC/EAN 128 Setting ♦
Disable function code conversion
Enable Code 128 and GS1-128
Enable function code conversion
Disable Code 128 and GS1-128
ISBT Concatenation Off
this selection automatically.
this selection automatically.
MS Default (01)
MS Default (98)
Code 128/EAN-128 Min. Length
Code 128/EAN-128 Max. Length

0 1 2 3 4 5 6 7
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ UK/Plessey Setting ♦
Select UK/Plessey Standard Format
Disable check digit transmission
Select UK/Plessey CLSI Format
Disable Convert X to A-F
Enable check digit transmission
this selection automatically.
this selection automatically.
Enable Convert X to A-F
MS Default (04)
MS Default (98)
UK/Plessey Max. Length
UK/Plessey Min. Length

0 1 2 3 4 5
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Telepen Setting ♦
Disable check digit transmission
Select Telepen Numeric mode
Select Telepen Full ASCII mode
Enable check digit transmission
this selection automatically.
this selection automatically.
MS Default (04)
MS Default (98)
Telepen Min. Length
Telepen Max. Length

0 1 2 3 4 5
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ GS1 DataBar Setting ♦
Only available for Expanded GS1 Databar.
Only available for Expanded GS1 Databar.
Enable GS1 DataBar Expanded
Enable GS1 DataBar (RSS-14)
Disable GS1 DataBar (RSS-14)
Enable GS1 DataBar Limited
Disable GS1 DataBar Expanded
Disable GS1 DataBar Limited
this selection automatically.
this selection automatically.
MS Default (04)
MS Default (74)
GS1 DataBar Min. Length
GS1 DataBar Max. Length

0 1 2 3
0 1 2 3
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
♦ Linear-stacked & Korea Post Code Setting ♦
Disable composite codes
Length fixed in 6 characters.
Korea Post Code Setting
Composite Codes Setting

Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix
1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.
♦ Keyboard Layout (Language) Setting ♦
United Kingdom - UK (QWERTY)
Spain (Latin America, QWERTY)
Keyboard Interface Message String :

The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will
perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission
[00-7F], [FIN]
0 1 2 3 4 5, (00-7F)
“Caps Lock On, Shift Off” 0 1
♦ Record Suffix, Preamble, Postamble & Caps Lock ♦
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
Maximum 15-character input; scan “FIN” to terminate this selection.
Maximum 15-character input; scan “FIN” to terminate this selection.
While selecting the other host interfaces, these selections don’t perform the above functions for you.
User defined character (1 character)
SS “Caps Lock On, Caps Off”
ENTER (Numeric Key Pad)
“Caps Lock Off” State
“Caps Lock On” State
handshaking without changing the status of Caps Lock switch.
TAB
Caps Lock Release Control

Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Delay Setting ♦
Interfunction Delay is a time delay between the transmission of each segment of the message string.
this selection automatically.
this selection automatically.
this selection automatically.
1-99 (x5) msec.
1-99 (x5) msec.
1-99 (x5) msec.
parameters.

Enable numeric output as key pad (Num Lock On) output 0 1
0 1 2 3
♦ Emulation Setting & Upper/Lower Case Setting ♦
SS Enable ASCII 00-31 code as keyboard function code output
Refer to Appendix – Keyboard Function Code Table for details.
Inverse case (change all characters output to inverse case)
Normal case (neglect the upper/lower case control)
Upper case (force all characters output as upper case)
Lower case (force all characters output as lower case)
SS Disable key pad emulation


STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix
1 character 1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character 1 character
STX/ETX are two characters used to indicate the starting and ending of the total
♦ Record Suffix, Preamble ,Postamble Setting ♦
Maximum 15-character input; scan “FIN” to terminate this selection.
Maximum 15-character input; scan “FIN” to terminate this selection.
Serial Interface Message String (RS232, USB COM) :

Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
♦ Delay Setting ♦
Interfunction Delay is a time delay between the transmission of each segment of the message string.
this selection automatically.
this selection automatically.
this selection automatically.
1-99 (x5) msec.
1-99 (x5) msec.
1-99 (x5) msec.
parameters.

When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after
After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner
will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner
SS 3 times 0~255 times FIN
0 1 2 3
0 1 2 3
This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.
the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.
♦ Protocol, ACK/NAK Setting ♦
each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.’
Enable ACK Time-out Indication
Disable ACK Time-out Indication
None (free running mode)
issues an error indication and discards the data under following two conditions:
Disable ACK Indication
Enable: There’s a specific LED and beeping indication for this setting.
Disable: There’s neither LED nor beeping indication for this setting.
USB COM doesn’t support RTS/CTS handshaking protocol.
NAK Retry Count
ACK Indication:

When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
B
4 5 8 9
B
D
E
0 1 2 3 4 5
0 1 2 3
0 1 2 3 4 5 6 7
♦Time Out Setting, Baud Rate, Data Frame ♦
3 seconds 4 seconds 5 seconds 8 seconds 10 seconds 15 seconds
7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2
communication. This option is very helpful to ensure the reliability of data communication.
200 mseconds 500 mseconds 800 mseconds 1 second 2 seconds
38.4K BPS 19.2K BPS 9600 BPS 4800 BPS
8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1

[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,
0 1 2 3 4
they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.
♦ Code 39/Code 128 Emulation ♦
Enable standard Code 39 skip emulation
Enable standard Code 39 replace emulation
Disable standard Code 39 emulation
Enable Full ASCII Code 39 emulation
Enable Code 128 emulation
Code 39/Code 128 Emulation

Low Power Mode (Low Power Triggering) The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation.
Trigger Mode (External Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner
Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is
similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work
Alternative Mode (Periodic Power Off) The scanner keeps the light source of the scanner turned on till the pre-defined light source on time is up. After the scanner turns
off the light source, you must press the trigger to turn on the light source again. After each good read, the timer counter of “Light Source on Time” is reset. You do not have
Flash Mode (Pulse Driven Reading) The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar
Force Mode (Continued Power On) The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for
Toggle Mode (Repeat Reading) The toggle mode is very similar to the Alternative Mode but without the pre-defined light source on time concern. You must press the
Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the
Level Mode (Auto Power Off) When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined
“Light Source on Time”. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press
the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after
Presentation Control When the scanner is placed on SmartStand, the scanner will be switched from hand-held scanning to hands free scanning automatically. Three
5 6 7 8
code, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.
properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “Presentation Sensitivity”).
0 1 2 3 4
trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again.
L680/L780 laser imagers don’t support:
Flash/ Force/ Toggle/ Diagnostic mode.
hands scanning modes are available. You are recommended to use flash mode or force mode while under insufficient ambient light.
Only Low power mode, Trigger mode, Presentation mode and Level mode are available for FuzzyScan Laser model.
scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.
♦ Operation Mode Setting ♦
L680/L780 laser imagers don’t support this function.
It is very helpful for mobile data collection and application, which are concerned with power saving.
to press the trigger frequently, it is very convenient for multiple scanning.
the pre-defined light source on time is up.
before scanning the bar code.
high speed bar code reading.

0 1 2 3 4 5 6
♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦
Optional function, only available for vibrator model.
Buzzer tone - extremely high
Buzzer tone – medium
LED steady on
Buzzer tone – mute
Buzzer tone – high
Buzzer tone – low

Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on
0 1 2 3 4
0 1 2 3 4 5
♦ Dollar Sign, Redundancy, Scan Rate Control♦
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
To prevent potential miss reading.
Dollar sign output as “ $ “
Dollar sign output as “¥“
Dollar sign output as “ € “
Dollar sign output as “ £ “
Dollar sign output as “ ¢ “
the move. But this may impact to the reading distance.

The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification
0 1 2 3
0 1 2 3 4 5
0 1 2 3 4 5 6
♦ Flash Duty Cycle, Delay Setting ♦
L680/L780 laser imagers don’t support this function.
This Good Read Delay is the minimum amount of time before the imager can read another bar code.
The Flash Duty Cycle is designed to control the flashing frequency of the light source.
Immediate time out
1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle
200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.
will not allow reading of the same bar code twice.
(Double Scan Verification) SS

The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on
The Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode
when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any
The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity. This setting is only available for the scanner is in low
0 1 2 3
0 1 2 3 4
0 1 2 3 4
0 1 2 3 4 5
♦ Time-out Setting, Good Read Duration ♦
till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.
trigger operation), the imager will revert to the original hands free mode.
1 sec 3 secs 5 secs 7 secs 9 secs Immediate
Time Delay to Low Power Mode
Light Source On Time
power mode.

The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on
SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the
Enable 0 1
0 1 2 3 4
♦ Presentation Scanning Setting , Trigger Control♦
Only available for FuuzzyScan Laser model
Only available for FuzzyScan F460/F468
Enable left trigger, disable right trigger
Enable right trigger, disable left trigger
Enable left and right triggers
3 mins 5 mins 10 mins
SmartStand Power Off Timeout
off when the pre-defined duration is up.
the barcode.
SmartStand.

Only available for L series laser imaging scanner.
♦ Laser Aiming Control♦
You can disable or enable laser aiming line when you scan PDF barcode.
Enable ◆ · SS Disable · Laser Aiming Control

DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,
you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
[00-7F], [FIN]
0 1 2 3 4 5 6
♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Maximum 15-character input; scan “FIN” to terminate this selection.
Maximum 15-character input; scan “FIN” to terminate this selection.
If data length exceeds 99, 3-digit data length will be transmitted.
Enable both prefix and suffix AIM symbology ID transmission
Enable both prefix and suffix symbology ID transmission
you to arrange the transmission of scanned data to any specific format without software modification.
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable 2 digits data length transmission
on-screen, under Windows 95/98/NT/2000/XP environment.
ease.

The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.

symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 45 for details.
♦ Data Formatter Setting ♦
All of the above programmable parameters perform the same function depending on your setting.

All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the

FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 45 for details.
♦ Data Verifier Setting ♦

The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it

arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 45 for details.
♦ Data Replacer Setting ♦
symbologies for replacer control, and provides Multiple Position Replacement in the identified position.

The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data
While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record

including or excluding the data of identification position. Please refer to the application example listed in page 45 for details.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 45 for details.
DS Transmitted data excluded the data of identified position
♦ Data Organizer Setting ♦
Please note that all “Character” input should be referred to the ASCII/HEX Table.
Suffix.

If your bar code label is a 16-digit Interleaved 2 of 5 which
includes the information of 6-digit date code, 6-digit serial
number and 4-digit unit price, you want the FuzzyScan do
Apply only Interleaved 2 of 5 to the condensed
Allow bar code output whose date code is leading with
The date code output should skip “9” and replaced it by
The unit price output should be skipped the first 2
following to calculate the actual position for identification.
If there is a 11-character data string, please refer to the
The serial number output should be led with “SN”.
X
00 01 02 03 04 05 06 07 08 09 10
the following for you without software modification:
Check bar code is actually with 16-digit length.
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6
Three outputs with “TAB” suffix.
Application Example Application Example Application Example Application Example
DataWizard.
digits.
“9”.
“A”.
You can select one or all types of bar code symbologies to
use Condensed DataWizard for advanced transmission
arrangement. If you scan “00” to select all types, the
FuzzyScan will arrange all incoming data to meet your
pre-defined format. If you want to select only one type bar
![Cino FuzzyScan Barcode Scanner (F700) — [Data Verifier, Data Replacer, Data Organizer] diagram (page 57)](/cdn/reader/8a/8af57336956b78abb15f268b6e2ba80464be0552a798430865c7c00ae3ca000c/images/fig-57-1.webp)
If there is a 5-character input data string, refer to the following
code, please select one of the option code listed below.
00 01 02 03 04 05
to calculate the actual position for insertion:
Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology
Position Calculation Position Calculation Position Calculation Position Calculation
EAN-13 with 2 supple. : 34
EAN-13 with 5 supple. : 44
UPC-A with 2 supple.: 32
UPC-A with 5 supple.: 42
UPC-E with 2 supple.: 33
UPC-E with 5 supple.: 43
UPC-A : 02
UPC-E : 03
![Page 58 of the Cino FuzzyScan Barcode Scanner (F700) user manual — [Data Formatter]](/cdn/reader/8a/8af57336956b78abb15f268b6e2ba80464be0552a798430865c7c00ae3ca000c/images/page-58.webp?w=400)
Scan “Replacer Control” and set bar code symbology
Scan “1st Replacement” and set the identified position
to “00”, then replaced character to “41” (Hex Code of
Scan “Organizer Control” and set bar code symbology
Scan “1st Organization” and set the identified position
Scan “2nd Organization” and set the identified position
to “17”, then set the data transmission to “1”
Please note that Condensed DataWizard will follow the
So when you set the identified position in Data Organizer,
you must consider the inserted data which you already set
to “16”, then set the data transmission to “0” (forward).
Verifier Formatter Replacer Organizer
Scan “END” (Exit) to terminate the programming.
preset working flow as below:
[Data Organizer]
[Data Replacer]
via Data Formatter.
(backward).
to “48”.
to “48”.
A).
Scan “Verifier Control” and set bar code symbology to “48”
Scan “1st Identified Character” and set the identified
position to “00”, then set the identified character to “39”
Scan “Formatter Control” and set bar code symbology to
Scan 1st Insertion” and set the identified position to “06”,
then inserted characters to “09” (Hex Code of TAB), “53”
Scan “2nd Insertion” and set the identified position to “12”,
then inserted character to “09”. In the final, you must scan
Scan “3rd Insertion” and set the identified position to “16”,
then inserted character to “09”. In the final, you must scan
Scan “Identified Data Length” and set the length to “16”.
Scan “Program” to enter the programming mode.
“FIN” (Finish) code to terminate this selection.
“FIN” (Finish) code to terminate this selection.
(Hex Code of S), “4E” (Hex Code of N).
Programming Procedure Programming Procedure Programming Procedure Programming Procedure
(Interleaved 2 of 5).
(Hex Code of 9).
[Data Verifier]
“48”.

UPC-A m EAN/JAN-8 4
UPC-A with 2 supple. 1 EAN/JAN-8 with 2 supple. 1
UPC-E m EAN/JAN-13 m
UPC-E with 2 supple. 1 EAN/JAN-13 with 2 supple. 1
Code 128 B m Code 93 Code 93 H G m Code 128
1 Code 11 Code 11 P H m
Codabar Codabar/NW-7 D F m MSI/Plessey MSI/Plessey R M m
Standard/Industrial 2 of 5 I S 0 UK/Plessey UK/Plessey S P 0
Matrix 2 of 5 K X 0 Telepen Telepen T B m
Composite Composite Code X e 0
China Postal Code L X 0 Code 39 G A m
German Postal Code M I 3 Code 39 Trioptic W X 0
Code 32 G A 0
UCC Coupon Code Z PDF417 PDF417/Micro PDF417 V L 0
Codablock Codablock F Y O 0
Korea Post Korea Post Code a X 0 UCC Coupon Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar
Cino ID AIM ID Cino ID AIM ID
F E
code is transmitted as ]E09923456789019]C181010123451297 Remark: Above examples are given for the transmission of AIM ID.
Code Family Primary Format Code
transmitted as ]E449123562]E212345
2 EAN/JAN-8 with 5 supple.
2 EAN/JAN-13 with 5 supple.
Interleaved 2 of 5 J I m GS1 DataBar GS1 Databar
Each AIM Code Identifier contains the three-character string ]cm where:
IATA IATA O R m
code is transmitted as]E0512345678900]C181010123451297
GS1-128 C C
Code Family Primary Format Code
transmitted as ]E0012345678950]E112
E
Symbology ID Table
UPC-A with 5 supple.
UPC-E with 5 supple.
m = Modifier Character
c = Code Character
] = Flag Character

To emulate the keyboard function key input for user definable parameters, user must configure actual content using the
Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done
by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.

No. ANSI ASCII Key Function No. ANSI ASCII Key Function
07 BEL 07H F1 23 ETB 17H DEL (Delete) (Edit)
11 VT 0BH F3 27 ESC 1BH PAGE DOWN (Edit)
06 ACK 06H ESC 22 SYN 16H INS (Insert) (Edit)
10 LF 0AH F2 26 SUB 1AH PAGE UP (Edit)
08 BS 08H BACK SPACE 24 CAN 18H HOME (Edit)
13 CR 0DH ENTER (CR) 29 GS 1DH DOWN (Edit)
15 SI 0FH F6 31 US 1FH RIGHT (Edit)
09 HT 09H TAB 25 EM 19H END (Edit)
14 SO 0EH F5 30 RS 1EH LEFT (Edit)
12 FF 0CH F4 28 FS 1CH UP (Edit)
04 EOT 04H CAPS LOCK 20 DC4 14H F11
05 ENQ 05H NUM LOCK 21 NAK 15H F12
01 SOH 01H CTRL (Left) 17 DC1 11H F8
02 STX 02H ALT (Left) 18 DC2 12H F9
Appendix


F SI US / ? O _ o DEL
L 0 1 2 3 4 5 6 7
0 NUL DLE SPACE 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAK % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 HT EM ) 9 I Y i y
B VT ESC + ; K [ k {
C FF FS , < L \ l |
D CR GS - = M ] m }
E SO RS . > N ^ n ~
: High Byte of HEX Value
: Low Byte of HEX Value
To configure the user definable parameters of FuzzyScan via
programming menu, FuzzyScan will ask you to scan your
desired ASCII value in HEX form. You have to refer to the
If you want the scanned data output leading with a Dollar
Sign, you have to set the “Preamble” to “$”. The configuration
Refer to the Hex/ASCII Table, you will find the HEX value
Scan the option code – 2 listed on the fold out back cover.
Scan the option code – 4 listed on the fold out back cover.
Scan the system command – FIN (Finish) to terminate
Scan the system command – End to exit the programming
Scan the system command – PROGRAM listed on page
Scan family code – PREAMBLE to select this family.
procedure is listed below for reference.
3-24 to enter programming mode.
“HEX/ASCII Table” for details.
mode for normal operation.
Preamble setting.
of “$” is 24.
Appendix

RS232 Serial PS/2 (DOS/V) KBW Standard Mode
Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode
USB HID Standard Mode
USB HID Turbo Mode
USB Com Port Emulation
Appendix

Low Power (Low power trigger) Force (Continued power on)
Presentation (Auto sensing) Diagnostic (Test reading)
Trigger (External triggering) Toggle (Repeat reading)
Alternative (Periodic power off)
Flash (Pulse driven reading)
Level (Auto power off)
Appendix

6 E
7 F
2 A
3 B
Option Codes
END (Exit) · Appendix · FIN (Finish)

Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and
(Enter Programming Mode) System Information List
FIN (Finish) PowerTool Host Link
(Exit Programming Mode) Factory Default
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.
would like to return to previous setting, please scan “User Default”.
Control, the rest of parameters will be returned to default value.

FuzzyScan Family Programming Manual
CINO GROUP PC WORTH INT’L CO., LTD.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.