EN
Cino logo
Official user manual

Cino FuzzyScan Barcode Scanner (F700)

66 pages·686 KB·Barcode Reader·PDF·ENDEFRITNLJA
Cino FuzzyScan Barcode Scanner (F700)
Table of Contents 77 sections BARCODE IMAGER · International Edition, Rev. C5 · Revision History · EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2 · … ShowHide
BARCODE IMAGERp.1International Edition, Rev. C5p.1Revision Historyp.2EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2p.4KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)p.4CNS13438p.4Regulatoryp.4Warrantyp.4Table of Contentsp.6Getting Startedp.6Appendixp.6Connecting to Your Hostp.7USBp.7Getting Familiar with Your FuzzyScanp.7Using Accessoriesp.8Bar Code Programming Menup.9“ M_DEFAULT ”p.11“ SYSLIST ”p.11“ END ”p.11Host Interface Selectionp.14MSp.14Family Code Selection P.C Parameter Selection Option Code 2nd Option Codep.15EAN-13 *p.17UPC-A *p.17UPC-E *p.17EAN-8 *p.17IATAp.17CSp.177 8 9 Ap.23Keyboard Interface Controlp.36USA (QWERTY) p.36[00-7F], [FIN]p.370 1 2 3 4 5, (00-7F)p.37RETURN p.37SPACEp.37TABp.37Serial Interface Controlp.406 7 8 9 Ap.438 9 Ap.432400 BPS 1200 BPS 57.6K BPS 115.2K BPSp.43Wand/Laser Emulation Controlp.44Operation Controlp.45Condensed DataWizardp.52[Data Verifier, Data Replacer, Data Organizer]p.57X X X X Xp.57[Data Formatter]p.57UCC/EAN 128 : 31p.57EAN-13 : 04p.57UPC-A : 02p.57UPC-E : 03p.57[Important Notice]p.58[Data Organizer]p.58[Data Replacer]p.58[Data Verifier]p.58N Ep.59F Ep.59EAN/JANp.59GS1-128 C Cp.59Symbology ID Tablep.59UPCp.59Keyboard Function Code Tablep.60HEX/ASCII Reference Tablep.61ASCII Input Shortcutp.61Example:p.61Host Interface Quick Setp.62Operation Mode Quick Setp.635 Dp.646 Ep.647 Fp.642 Ap.643 Bp.64Option Codesp.64(SYSLIST)p.65System Commandsp.65ENDp.65www.cino.com.twp.66FuzzyScan Family Programming Manualp.66
Page 1 of the Cino FuzzyScan Barcode Scanner (F700) user manual — International Edition, Rev. C5
Page 1 · click to enlarge
Page 1

BARCODE IMAGER

International Edition, Rev. C5

Page 2 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Revision History
Page 2 · click to enlarge
Page 2

Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4”

Rev. No.Released DateDescription Rev.B BetaApr. 16, 2009First Release Rev.BMay 05, 2009 Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4” and ISBT Concatenation On option code to “5”. Page 25 GS1 Databar Setting – All GS1 databar default values are changed to Enable. Page 46 Add “Symbology ID Table”. Rev.B1June 22, 2009 Page 34 Add “Presentation Scanning Mode”. Page 37 Add “Time Delay to Low Power Mode”. Rev.B2Aug. 21, 2009 Page 9, 11 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code”. Page 26 Add “Composite Code Setting”, “PDF/Micro PDF417 Setting”, “Codablock F Setting”, Korea Post Code Setting”. Page 39 Add “SmartStand Power Off Timeout”. Page 46 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code” into Condensed DataWizard Table. Page 48 Add “PDF417/Micro PDF417”, “Codablock F”, “Composite Code”, “Korea Post Code” IDs into Symbology ID Table. Rev.B3Oct. 16, 2009 Page 8 Add “IBM PS/2, 25-30 series keyboard wedge interface”. Page 39 Add “Presentation Scanning Auto-sense”. Page 48 Add “Code 128” ID into Symbology ID Table. Rev.B4Mar. 05, 2010 Page 15 Modify UPC-E/EAN-8 expansion and UPC-A standardization Page 33 Rename “Time Out Control” to “Serial Response Time-out”. Page 35 Rename “Presentation Scanning Mode” to “Presentation Control”. Page 38 Rename “Auto Power Off Duration” to “Light Source On Time”. Add “Extremely short” option to Good Read Duration. Page 39 Rename “Presentation Scanning Auto-sense” to “Presentation Auto-sense”. Add “Presentation Sensitivity” Page 54 System Commands – Add “Master Default” quick set command. Rev. B5Apr.12, 2010 Page 38 Hands Free Time-out – Add “Disable”. Page 39 Add “Trigger Control” (only available for FuzzyScan F460/F468).

Rev. No. Released Date Description

Revision History

Rev.B Beta Apr. 16, 2009 First Release

Cino FuzzyScan Barcode Scanner (F700) — Revision History diagram (page 2)
Fig. 1 · Revision History
Page 3 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Revision History
Page 3 · click to enlarge
Page 3
Rev. No.Released DateDescription Rev. B6May 27, 2010 Page 33 Baud Rate – Add 57.6K BPS and 115.2K BPS. Rev. B7Jun 25 , 2010 Page 17 Add “UPC/EAN Security Level”. Page 38 Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate. Rev. B8Sep 29 , 2010 Page 15,16 Add “ Supplement Scan Voting”. Page 17 Add “EAN Supplement Control”. Page 28 Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to Spain (Latin America, QWERTY). Page 37 Add “Good Read Indicator”. Page 38 “Scan Rate Control”. Rev. B9Nov 10 , 2010 Page 34 Baud Rate – Cancel Baud Rate 300/600 BPS. Rev. C1Mar 04, 2011 Page 34 Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9. Rev. C2Mar 22, 2011 Page 13 Add ”Code 39 Security Level”. Page 35 Add “NAK Retry Count”. Add “ACK/NAK Transmission Indication”. Rev. C3Jul 22, 2011 Page 9, 19, 24, 51 UCC/EAN-128 was renamed GS1-128 Page 35 Add new parameters to “ACK Indication” Page 36 Modify “Serial Response Time-out” parameters. Page 44 Add “Laser Aiming Control” function. Rev. C4Nov 04, 2011 Page 14 Add “Codabar Check Digit Settings” Rev. C5Jan 02, 2012 Page 38 Wand/Laser Emulation Control – Cancel “Output Polarity”, “Initial Signal State”, “Margin Time”, “Module Time” ,and “Narrow/Wide Ratio” Page 38 Code 39/Code 128 Emulation – Change the default setting to option code 1.

Rev. B6 May 27, 2010 Page 33 Baud Rate – Add 57.6K BPS and 115.2K BPS.

Rev. No. Released Date Description

Revision History

Rev. B8 Sep 29 , 2010

Rev. C3 Jul 22, 2011

Rev. C5 Jan 02, 2012

Page 4 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Regulatory
Page 4 · click to enlarge
Page 4

Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of

merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental

consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains

proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,

reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written

permission of Cino. All product information and specifications shown in this document may be changed without prior notice.

Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the

product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different

warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident

or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized

representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied

software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but

not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA

EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2

KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)

AS/NZS CISPR 22:2009 Class B

procedures to return Cino for inspection.

© Copyright PC Worth Int’l Co., Ltd

CNS13438

© Copyright Cino Group

Regulatory

Warranty

FCC part 15B

Page 5 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2
Page 5 · click to enlarge
Page 5

LED Eye Safety IEC62471 Exempt group

Laser Eye Safety IEC60825-1 Class 1

Page 6 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Table of Contents
Page 6 · Contents
Contents

Contents

BARCODE IMAGERp.1International Edition, Rev. C5p.1Revision Historyp.2EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2p.4KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)p.4CNS13438p.4Regulatoryp.4Warrantyp.4Table of Contentsp.6Getting Startedp.6Appendixp.6Connecting to Your Hostp.7USBp.7Getting Familiar with Your FuzzyScanp.7Using Accessoriesp.8Bar Code Programming Menup.9“ M_DEFAULT ”p.11“ SYSLIST ”p.11“ END ”p.11Host Interface Selectionp.14MSp.14Family Code Selection P.C Parameter Selection Option Code 2nd Option Codep.15EAN-13 *p.17UPC-A *p.17UPC-E *p.17EAN-8 *p.17IATAp.17CSp.177 8 9 Ap.23Keyboard Interface Controlp.36USA (QWERTY) p.36[00-7F], [FIN]p.370 1 2 3 4 5, (00-7F)p.37RETURN p.37SPACEp.37TABp.37Serial Interface Controlp.406 7 8 9 Ap.438 9 Ap.432400 BPS 1200 BPS 57.6K BPS 115.2K BPSp.43Wand/Laser Emulation Controlp.44Operation Controlp.45Condensed DataWizardp.52[Data Verifier, Data Replacer, Data Organizer]p.57X X X X Xp.57[Data Formatter]p.57UCC/EAN 128 : 31p.57EAN-13 : 04p.57UPC-A : 02p.57UPC-E : 03p.57[Important Notice]p.58[Data Organizer]p.58[Data Replacer]p.58[Data Verifier]p.58N Ep.59F Ep.59EAN/JANp.59GS1-128 C Cp.59Symbology ID Tablep.59UPCp.59Keyboard Function Code Tablep.60HEX/ASCII Reference Tablep.61ASCII Input Shortcutp.61Example:p.61Host Interface Quick Setp.62Operation Mode Quick Setp.635 Dp.646 Ep.647 Fp.642 Ap.643 Bp.64Option Codesp.64(SYSLIST)p.65System Commandsp.65ENDp.65www.cino.com.twp.66FuzzyScan Family Programming Manualp.66
Page 7 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Getting Familiar with Your FuzzyScan
Page 7 · click to enlarge
Page 7
Cino FuzzyScan Barcode Scanner (F700) — Connecting to Your Host diagram (page 7)
Fig. 2 · Connecting to Your Host

FuzzyScan imagers support PS/2(DOS/V) Keyboard

Wedge, RS-232 Serial, and USB interfaces. Please

choose your desired interface cable, then plug it into the

cable interface port of the imager and connect it to the

host. If you would like to remove the cable, please

straighten one end of a paper clip, then insert it into the

cable release hole to pull out the cable.

Connecting to Your Host

Cino FuzzyScan Barcode Scanner (F700) — Connecting to Your Host diagram (page 7)
Fig. 3 · Connecting to Your Host
Cino FuzzyScan Barcode Scanner (F700) — Connecting to Your Host diagram (page 7)
Fig. 4 · Connecting to Your Host
Cino FuzzyScan Barcode Scanner (F700) — Connecting to Your Host diagram (page 7)
Fig. 5 · Connecting to Your Host
Cino FuzzyScan Barcode Scanner (F700) — Connecting to Your Host diagram (page 7)
Fig. 6 · Connecting to Your Host

USB

Thank you for choosing Cino FuzzyScan Imager. All

FuzzyScan imagers deliver world-class performance for a

broad range of applications to unleash your productivity. This

document provides an easy reference for installation and

operation purposes. A complete documentation is provided

by the FuzzyScan Programming Manual available at

Getting Familiar with Your FuzzyScan

Cino FuzzyScan Barcode Scanner (F700) — Getting Familiar with Your FuzzyScan diagram (page 7)
Fig. 7 · Getting Familiar with Your FuzzyScan
Cino FuzzyScan Barcode Scanner (F700) — Getting Familiar with Your FuzzyScan diagram (page 7)
Fig. 8 · Getting Familiar with Your FuzzyScan
Cino FuzzyScan Barcode Scanner (F700) — Getting Familiar with Your FuzzyScan diagram (page 7)
Fig. 9 · Getting Familiar with Your FuzzyScan

F700 & L700 Series

F600 & L600 Series

www.cino.com.tw

Show 10 more labels / short text on this page
PS/2(DOS/V) Keyboard Wedge · RS232 Serial · Getting Started · Cable Release Hole · Power Indicator · Status Indicator · Scan Window · Trigger · Beeper · F400 Series
Page 8 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Using Accessories
Page 8 · click to enlarge
Page 8

You can enhance productivity of your workforce by using

various accessories to fulfill a wide variety of application

A stylish Universal Holder is designed for

storing your imager when not in use. It

serves to protect the imager from

lens-scratched or falling. Moreover, its

artistic-design enhances the entire value

A SmartStand is specifically designed

for hand-free applications to maximize

user’s comfort and productivity. You

can adjust the scanner holder to

desired position for optimized

Thanks to the auto-sense design, the

imager is capable of switching

between presentation scanning and

Please note that the SmartStand is

not applicable for F400 Series imager.

while working with SmartStand.

of the imager.

scanning.

Using Accessories

Cino FuzzyScan Barcode Scanner (F700) — Using Accessories diagram (page 8)
Fig. 10 · Using Accessories
Cino FuzzyScan Barcode Scanner (F700) — Using Accessories diagram (page 8)
Fig. 11 · Using Accessories

demand.

Show 4 more labels / short text on this page
Getting Started · hand-held scanning automatically · Hand-free SmartStand · Universal Holder
Page 9 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Bar Code Programming Menu
Page 9 · click to enlarge
Page 9

The System Command is the highest level bar code

command which directs FuzzyScan to perform immediate

operations, such as entering programming mode

(PROGRAM), exiting programming mode (EXIT), listing

system information (SYSLIST), recovering to factory

preset configurations (M_DEFAULT) and so on. Please

complete the operations. User must wait for the

The Family Code is scanned to select the user desired

programming family. FuzzyScan has already provided

more than one hundred programming families to meet any

The Option Codes is a set of bar code commands

represented by “0–9”, “A–F” and finishing selection (FIN).

For most setting, you must select at least one option code

following the family code selection to set the desired

completion beeps before scanning another bar code.

parameter for the selected programming family.

System Command System Command System Command System Command

specific requirements.

Option Code Option Code Option Code Option Code

Family Code Family Code Family Code Family Code

The FuzzyScan bar code commands are specially designed

Proprietary bar code labels which allow you to set the

FuzzyScan internal programming parameters. There are

System Command, Family Code and Option Code for

Each programmable family and bar code command label is

listed on the same page with major system commands. The

detailed explanations and special programming flowchart are

printed on facing or following pages. You can read the

A supplemental bar code command menu incorporates the

bar code command labels of System Command and Option

Code. As you set the FuzzyScan, open the bar code

command menu to find the option code page. You may scan

the desired family code and option code to set FuzzyScan. If

you want to change the programming family for multiple

settings, you need only turn over the programming page to

explanation and set the FuzzyScan concurrently.

Bar Code Programming Menu

find next desired programming family.

programming purpose.

Page 10 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Bar Code Programming Menu
Page 10 · click to enlarge
Page 10

If the programming family must take multiple scans

selection, cycling scan selection, or dual level selection

procedures, the family of the programming menu will be

marked with the matched representing symbol of

Programming Category (P.C.) in bold font listed in the

following table. You can easily find the bold mark in the

programming menu, and refer to their flowcharts for details.

Before setting the FuzzyScan, please also refer to the

“Beeping Indications” listed in Appendix to understand the

details of programming beeping indications. It will be very

helpful for you to know the existing status while you are

MSMultiple scans selection
DSDual level scan selection
CSCycling scan selection

P.C. Programming Category

SSSingle scan selection

( ) Necessary Option Code

[ ] Selectable Option Code

Conventions of Pr Conventions of Pr Conventions of Pr Conventions of Programming Menu ogramming Menu ogramming Menu ogramming Menu

Factory Default Value

programming the FuzzyScan.

ConventionsDescriptions Factory Default Value P.C.Programming Category SS : Single scan selection MS : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection ( )Necessary Option Code [ ]Selectable Option Code

As you scan the bar code command to select the desired

parameters, information about the final selected parameters

represented by the bar code commands are stored in the

FuzzyScan’s internal Flash Memory ASIC or non-volatile

memory. If you turn off the unit, the Flash Memory ASIC or

non-volatile memory retains all programming options. You

need not re-program the FuzzyScan if you want to keep the

The programming procedures of FuzzyScan are designed

as simple as possible for ease of setting. Most

programming families take the Single Scan Selection

programming procedure. But several programming families

have more complex and flexible programmable options,

and you must take Multiple Scans Selection, Cycling

Scan Selection or Dual Level Selection to complete their

programming procedures. Each kind of programming

procedure is listed in the following pages for your reference.

Please give careful attention to become familiar with each

existing configurations in the next power on.

Programming Procedures Programming Procedures Programming Procedures Programming Procedures

programming procedure.

Conventions Descriptions

Page 11 of the Cino FuzzyScan Barcode Scanner (F700) user manual — “ END ”
Page 11 · click to enlarge
Page 11

revision number to host via selected host interface,

FuzzyScan will list the product information and

parameters into factory preset configurations,

System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default

FuzzyScan will recover all programmable

then issue the completion beeping.

then issue the completion beeping.

“ M_DEFAULT ”

“ SYSLIST ”

Please note that the FuzzyScan will take 3-4 seconds to

store parameters in internal Flash Memory ASIC or

non-volatile memory after you scan the “END”. Please

don’t turn off the power before the completion beeping. It

parameters in Flash Memory ASIC or non-volatile memory,

FuzzyScan will exit programming mode, and store all

and inhibit all non-programming functions.

FuzzyScan will enter programming mode,

then issue the completion beeping.

may destroy all configured parameters.

“ END ”

Program & End Program & End Program & End Program & End

Show 4 more labels / short text on this page
Scan · Scan · Scan · Scan
Page 12 of the Cino FuzzyScan Barcode Scanner (F700) user manual — “ END ”
Page 12 · click to enlarge
Page 12

Enter programming mode.

option codes to select

option code selection.

1. Select one or several
2. If it’s necessary, scan

Exit programming mode.

desired parameters.

programming families.

Want to select another

Select one of desired

Multiple scans selection Multiple scans selection Multiple scans selection Multiple scans selection

One of Family Codes

“ END ”

Enter programming mode.

Select one option code of

Exit programming mode.

programming families.

Want to select another

Select one of desired

desired parameter.

Single scan selection Single scan selection Single scan selection Single scan selection

One of Option Codes

One of Family Codes

“ END ”

Show 20 more labels / short text on this page
“FIN” to terminate · programming family? · Several Option Codes · Scan One or · Selection · Repeat · No · Scan · Scan · Scan · Yes · programming family? · No · Selection · Scan · Scan · Scan · Repeat · Scan · Yes
Page 13 of the Cino FuzzyScan Barcode Scanner (F700) user manual — “ END ”
Page 13 · click to enlarge
Page 13

Select several option codes

option codes of desired

Enter programming mode.

1. Select one or several
2. If it’s necessary, scan

option code selection.

of desired parameters.

Exit programming mode.

programming families.

Want to select another

Select one of desired

parameters.

One of Family Codes

(2nd) Scan One or

Dual lev Dual lev Dual lev Dual level selection el selection el selection el selection

(1st) Scan

“ END ”

Enter programming mode.

Finish cycling selection.

several option codes of

Exit programming mode.

programming families.

Cycling select one or

Want to select another

Select one of desired

scans selection.

One of Family Codes

One of Option Codes

Cycling scan selection Cycling scan selection Cycling scan selection Cycling scan selection

Scan “FIN”

“ END ”

Show 23 more labels / short text on this page
“FIN” to terminate · programming family? · Several Option Codes · Several Option Codes · Selection · No · Scan · Scan · Repeat · Scan · Yes · desired parameters as · “Single” or “Multiple” · programming family? · (If necessary) · No · Selection · Scan · Scan · Repeat · Scan · Scan · Yes
Page 14 of the Cino FuzzyScan Barcode Scanner (F700) user manual — MS
Page 14 · click to enlarge
Page 14

02 06 08 09 10 13 14 17 18 19

Host Interface Selection

IBM PS/2, 25-30 series keyboard wedge interface

PS/2 (DOS/V) direct link (keyboard replacement)

PS/2 (DOS/V) keyboard wedge standard mode

PS/2 (DOS/V) keyboard wedge turbo mode

Standard/TTL RS-232 peer-to-peer serial

USB HID standard mode

USB Com Port Emulation

USB HID turbo mode

MS

MS

MS

MS

MS

MS

MS

MS

MS

MS

Wand emulation · Laser emulation · Host Interface Selection

Page 15 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Page 15 · click to enlarge
Page 15

Family Code Selection P.C Parameter Selection Option Code 2nd Option Code

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 26

♦ User Defined Symbol ID ♦

UCC Coupon Extended Code (Default=Z)

Standard/Industrial 2 of 5 (default=I)

PDF417/Micro PDF417 (default=V)

German Postal Code (default=M)

China Postal Code (default=L)

Code 39/Code 32 (default=G)

Interleaved 2 of 5 (default=J)

Trioptic Code 39 (Default=W)

Korea Post Code (default =a)

Codabar/NW-7 (default=D)

Matrix 2 of 5 (default=K)

MSI/Plessey (default=R)

GS1 DataBar (default=X)

Codablock F (default=Y)

UK/Plessey (default=S)

DS Code 128 (default=B)

GS1-128 (default=C)

Code 93 (default=H)

Code 11 (default=P)

UPC-A (default=A)

EAN-13 (default=F)

Telepen (default=T)

UPC-E (default=E)

IATA (default=O)

EAN-8 (default=N)

Symbol ID1 character
Show 25 more labels / short text on this page
(1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character) · (1 character)
Page 16 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Page 16 · click to enlarge
Page 16

0 1 2 3 4 5 6

♦ Symbology ID Transmission ♦

Enable both prefix and suffix CINO symbology ID transmission

Enable both prefix and suffix AIM symbology ID transmission

Enable prefix CINO symbology ID transmission

Enable suffix CINO symbology ID transmission

Enable prefix AIM symbology ID transmission

Enable suffix AIM symbology ID transmission

Disable symbology ID transmission

Symbology ID Transmission

Page 17 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 *
Page 17 · click to enlarge
Page 17

If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add

00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21

When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.

Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.

♦ Readable Bar Code Setting ♦

the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.

Standard/Industrial 2 of 5

GS1 DataBar (RSS-14) *

Interleaved 2 of 5 *

Matrix 2 of 5

EAN-13 *

UPC-A *

UPC-E *

EAN-8 *

IATA

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

CS

Remember to scan “FIN” to terminate

“ Auto ”, FuzzyScan will terminate this

this selection. But if you select the

selection automatically.

Show 16 more labels / short text on this page
PDF417/Micro PDF417 · German Postal Code · China Postal Code · Korea Post Code · Codabar/NW-7 * · Trioptic Code 39 · Codablock F · MSI/Plessey · Code 128 * · UK/Plessey · Auto · Code 39 * · Code 93 * · Code 11 · Telepen · Readable Symbology Setting
Page 18 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 *
Page 18 · click to enlarge
Page 18
Cino FuzzyScan Barcode Scanner (F700) — EAN-13 * diagram (page 18)
Fig. 12

0 1 2 3 4 5 6 7 8 9 A

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Select Code 32 (PARAF, Italian Pharmaceutical) as primary format

♦ Code 39/Code 32 Setting ♦

Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

Code 39 Family Setting

Trioptic Code 39 Setting

Code 39 Min. Length

Code 39 Max. Length

Page 19 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 *
Page 19 · click to enlarge
Page 19

Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.

0 1 2 3

Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.

Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.

Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.

♦ Code 39 Setting ♦

The scanner offers four levels of decode security for Code39 bar codes:

Code 39 Security Level

Code 39 Security Level

Show 4 more labels / short text on this page
Level 2 · Level 3 · Level 0 · Level 1
Page 20 of the Cino FuzzyScan Barcode Scanner (F700) user manual — B
Page 20 · click to enlarge
Page 20

0 1 2 3 4 5 6 7 8 9 A

B

D

E

0 1 2 3 4 5 6

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Codabar/NW-7 Setting ♦

Enable ABCD/ABCD start/stop symbol transmission

Enable ABCD/TN*E start/stop symbol transmission

Enable abcd/abcd start/stop symbol transmission

Enable abcd/tn*e start/stop symbol transmission

Disable start/stop symbol transmission

Select Codabar standard format

Disable check digit transmission

Disable check digit verification

Enable check digit transmission

Enable check digit verification

Runes (Modulus 10/weight 2)

Select Codabar ABC format

Select Codabar CLSI format

this selection automatically.

Select Codabar CX format

7 check DR Weight Modulus 11

MS Default (04)

Codabar Check Digit Settings

Codabar Min. Length

Show 9 more labels / short text on this page
(2 digits) · Modulus 10/weight 3 · Modulus 10/weight 2 · Enable Codabar · Modulus 16 · Disable Codabar · 01-Maximum · Modulus 11 · Codabar Setting
Page 21 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 *
Page 21 · click to enlarge
Page 21

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Codabar/NW-7 Setting ♦

this selection automatically.

MS Default (98)

Codabar Max. Length

(2 digits) · 98-Minimum

Page 22 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 *
Page 22 · click to enlarge
Page 22
Cino FuzzyScan Barcode Scanner (F700) — EAN-13 * diagram (page 22)
Fig. 13

When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric

Cino FuzzyScan Barcode Scanner (F700) — EAN-13 * diagram (page 22)
Fig. 14

UPC-A 12 - 1 - 1 + 2 + 5 + 1 0 UPC-E 8 - 1 - 1 + 2 + 5 + 1 + 4

EAN-13 13 - 1 NC + 2 + 5 NC 0 EAN-8 8 - 1 NC + 2 + 5 NC + 5

0 1 2 3 4 5 6 7 8 9 A

UPC-E & EAN-8 Expansion : Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.

UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option.

♦ UPC-A & UPC-E Setting ♦

UPC-A Standardization : Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.

system, UPC-A check digit transmission.

UPC Family Setting · WPC Selection

Page 23 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 23 · click to enlarge
Page 23

Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this

Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may

The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding

a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5

supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,

7 8 9 A

B

D

Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6

Only available for UPC-A & EAN-13

♦ UPC-A & UPC-E Setting ♦

Disable force supplement digits output

Select UPC without supplement digits

Select UPC with only 2 supplement digits

Select UPC with only 5 supplement digits

UPC Family Addenda Separator Off

Select UPC with 2/5 supplement digits

Enable force supplement digits output

UPC Family Addenda Separator On

security level may significantly impair the decoding ability of the scanner.

The scanner offers three levels of decode security for UPC/EAN bar codes:

low contrast or damage barcode labels.

increase the misread.

UPC/EAN Security Level

Show 20 more labels / short text on this page
Level 7 · Level 10 · Level 11 · Level 12 · Level 13 · Level 8 · Level 9 · Level 3 · Level 1 · Level 1 · Level 2 · Level 6 · Level 0 · Level 2 · Level 4 · Level 5 · None · UPC Supplement Setting · UPC/EAN Security Level · Supplement Scan Voting
Page 24 of the Cino FuzzyScan Barcode Scanner (F700) user manual — B
Page 24 · click to enlarge
Page 24

The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding

a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5

supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,

7 8 9 A

B

D

0 1 2 3 4 5 6 7 8 9 A

B

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6

♦ EAN Setting, EAN Supplement Setting ♦

Disable ISBN/ISSN Conversion reading check

Enable EAN-13 check digit transmission

Enable ISBN/ISSN Conversion reading check

Enable EAN-8 check digit transmission

Disable force supplement digits output

Select EAN without supplement digits

Disable EAN-13 check digit transmission

Select EAN with only 2 supplement digits

Select EAN with only 5 supplement digits

Disable EAN-8 check digit transmission

Select EAN with 2/5 supplement digits

Enable force supplement digits output

EAN Addenda Separator Off

Disable EAN-8 expansion

EAN Addenda Separator On

low contrast or damage barcode labels.

Show 22 more labels / short text on this page
Level 7 · Level 10 · Level 11 · Level 12 · Level 13 · Level 8 · Level 9 · Enable EAN-8 expansion · Enable EAN-13 · Enable EAN-8 · Disable EAN-13 · Disable EAN-8 · Level 3 · Level 1 · Level 2 · Level 6 · Level 4 · Level 5 · None · Supplement Scan Voting · EAN Supplement Setting · EAN Setting
Page 25 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 25 · click to enlarge
Page 25

Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this

Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may

If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement

If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5

Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

0 1 2 3 4 5 6 7

Only available for UPC-A & EAN-13

♦ EAN Security Level Setting ♦

supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.

Disable all specific prefix supplement digital output

Enable all specific prefix supplement digital output

digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.

Enable 978/979 Supplement Digit Output

Enable 378/379 Supplement Digit Output

Enable 414/419 Supplement Digit Output

Enable 434/439 Supplement Digit Output

Enable 491 Supplement Digit Output

Enable 977 Supplement Digit Output

security level may significantly impair the decoding ability of the scanner.

The scanner offers three levels of decode security for UPC/EAN bar codes:

increase the misread.

UPC/EAN Security Level

EAN Supplement Control

Show 5 more labels / short text on this page
Level 1 · Level 0 · Level 2 · UPC/EAN Security Level · EAN Supplement Control
Page 26 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 26 · click to enlarge
Page 26

When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128

Enable UCC Coupon Extended Code 0 1

♦ UCC Coupon Extended Code Setting ♦

Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.

SS Disable UCC Coupon Extended Code

UCC Coupon Extended Code

UCC Coupon Extended Code

Page 27 of the Cino FuzzyScan Barcode Scanner (F700) user manual — B
Page 27 · click to enlarge
Page 27

0 1 2 3 4 5 6 7 8 9 A

B

0 1 2 3 4 5 6 7 8

♦ IATA & Interleaved 2 of 5 Setting ♦

Enable CPN, Airline and S/N check digit verification

Select 15-digit fixed length IATA checking

Select Interleaved 2 of 5 as primary format

Select German Postal Code as primary format

Disable start/stop symbol transmission

Enable S/N checking digit verification only

Enable CPN checking digit verification only

Enable check digit automatic verification

Enable start/stop symbol transmission

Disable check digit transmission

Disable check digit transmission

Disable check digit verification

Enable check digit transmission

Enable check digit transmission

Enable Interleaved 2 of 5

Select variable length IATA

Disable Interleaved 2 of 5

Validate OPCC check digit

Validate USS check digit

No check character

Interleaved 2 of 5 Setting

Disable IATA · Enable IATA · IATA Setting

Page 28 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 28 · click to enlarge
Page 28

For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable

0 1 2 3 4 5 6 7 8 9

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Code 25 Family Setting ♦

Disable Standard/Industrial 2 of 5

Disable check digit verification

Disable check digit transmission

Enable check digit transmission

Enable Standard/Industrial 2 of 5

Disable China Postal Code

Enable check digit verification

this selection automatically.

this selection automatically.

Enable China Postal Code

Disable Matrix 2 of 5

Enable Matrix 2 of 5

MS Default (04)

MS Default (98)

length of Code 25 will increase the possibility of reading error.

Code 25 Family Min. Length

Code 25 Family Max. Length

Show 5 more labels / short text on this page
(2 digits) · (2 digits) · 01-Maximum · 98-Minimum · Code 25 Setting
Page 29 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 29 · click to enlarge
Page 29
Cino FuzzyScan Barcode Scanner (F700) — 7 8 9 A diagram (page 29)
Fig. 15

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Code 11 & Code 93 Setting ♦

Code 11 Min. Length

Code 11 Max. Length

Code 93 Min. Length

Code 93 Max. Length

Code 93 Setting · Code 11 Setting

Page 30 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 30 · click to enlarge
Page 30

0 1 2 3 4 5 6

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ MSI/Plessey Setting ♦

Disable check digit transmission

Enable check digit transmission

Select MOD 10 check digit

Select MOD 10-10 check digit

Select MOD 11-10 check digit

this selection automatically.

this selection automatically.

MS Default (04)

MS Default (98)

MSI/Plessey Min. Length

MSI/Plessey Max. Length

Show 7 more labels / short text on this page
(2 digits) · (2 digits) · Disable MSI/Plessy · Enable MSI/Plessy · 01-Maximum · 98-Minimum · MSI/Plessey Setting
Page 31 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 31 · click to enlarge
Page 31

0 1 2 3 4 5

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Code 128 & UCC/EAN 128 Setting ♦

Disable function code conversion

Enable Code 128 and GS1-128

Enable function code conversion

Disable Code 128 and GS1-128

ISBT Concatenation Off

this selection automatically.

this selection automatically.

MS Default (01)

MS Default (98)

Code 128/EAN-128 Min. Length

Code 128/EAN-128 Max. Length

Show 6 more labels / short text on this page
(2 digits) · (2 digits) · ISBT Concatenation On · 01-Maximum · 98-Minimum · Code 128/EAN-128 Setting
Page 32 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 32 · click to enlarge
Page 32

0 1 2 3 4 5 6 7

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ UK/Plessey Setting ♦

Select UK/Plessey Standard Format

Disable check digit transmission

Select UK/Plessey CLSI Format

Disable Convert X to A-F

Enable check digit transmission

this selection automatically.

this selection automatically.

Enable Convert X to A-F

MS Default (04)

MS Default (98)

UK/Plessey Max. Length

UK/Plessey Min. Length

Show 7 more labels / short text on this page
(2 digits) · (2 digits) · Disable UK/Plessey · Enable UK/Plessey · 01-Maximum · 98-Minimum · UK/Plessey Setting
Page 33 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 33 · click to enlarge
Page 33

0 1 2 3 4 5

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ Telepen Setting ♦

Disable check digit transmission

Select Telepen Numeric mode

Select Telepen Full ASCII mode

Enable check digit transmission

this selection automatically.

this selection automatically.

MS Default (04)

MS Default (98)

Telepen Min. Length

Telepen Max. Length

Show 7 more labels / short text on this page
(2 digits) · (2 digits) · Disable Telepen · Enable Telepen · 01-Maximum · 98-Minimum · Telepen Setting
Page 34 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 34 · click to enlarge
Page 34

0 1 2 3 4 5

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

♦ GS1 DataBar Setting ♦

Only available for Expanded GS1 Databar.

Only available for Expanded GS1 Databar.

Enable GS1 DataBar Expanded

Enable GS1 DataBar (RSS-14)

Disable GS1 DataBar (RSS-14)

Enable GS1 DataBar Limited

Disable GS1 DataBar Expanded

Disable GS1 DataBar Limited

this selection automatically.

this selection automatically.

MS Default (04)

MS Default (74)

GS1 DataBar Min. Length

GS1 DataBar Max. Length

Show 5 more labels / short text on this page
(2 digits) · (2 digits) · 01-Maximum · 74-Minimum · GS1 DataBar Setting
Page 35 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 7 8 9 A
Page 35 · click to enlarge
Page 35

0 1 2 3

0 1 2 3

If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.

If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.

♦ Linear-stacked & Korea Post Code Setting ♦

UPC Composite ModeUPC never linked
UPC Composite ModeUPC always linked

Disable composite codes

Length fixed in 6 characters.

Korea Post Code Setting

Composite Codes Setting

Show 12 more labels / short text on this page
Enable 0 1 · Disable MicroPDF417 · Enable composite codes · Enable MicroPDF417 · Enable PDF417 · Disable PDF417 · SS Disable · SS Disable · Enable · PDF417/Micro PDF417 Setting · Composite Codes Setting · Codablock F Setting
Page 36 of the Cino FuzzyScan Barcode Scanner (F700) user manual — USA (QWERTY)
Page 36 · click to enlarge
Page 36

Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix

1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character

To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.

♦ Keyboard Layout (Language) Setting ♦

Keyboard Interface Control

United Kingdom - UK (QWERTY)

Spain (Latin America, QWERTY)

USA (QWERTY)

Keyboard Interface Message String :

Show 16 more labels / short text on this page
Switzerland-Germany (QWERTY) · Canadian French (QWERTY) · Spain (Spanish, QWERTY) · Sweden/Finland (QWERTY) · Netherlands (QWERTY) · Germany (QWERTZ) · Portugal (QWERTY) · Denmark (QWERTY) · Norway (QWERTY) · Belgium (AZERTY) · Iceland (QWERTY) · France (AZERTY) · Czech (QWERTY) · Italy (QWERTY) · Japan (DOS/V) · Keyboard Layout
Page 37 of the Cino FuzzyScan Barcode Scanner (F700) user manual — SPACE
Page 37 · click to enlarge
Page 37

The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.

Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will

perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission

[00-7F], [FIN]

[00-7F], [FIN]

0 1 2 3 4 5, (00-7F)

“Caps Lock On, Shift Off” 0 1

♦ Record Suffix, Preamble, Postamble & Caps Lock ♦

Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)

Keyboard Interface Control

Maximum 15-character input; scan “FIN” to terminate this selection.

Maximum 15-character input; scan “FIN” to terminate this selection.

While selecting the other host interfaces, these selections don’t perform the above functions for you.

User defined character (1 character)

SS “Caps Lock On, Caps Off”

ENTER (Numeric Key Pad)

“Caps Lock Off” State

“Caps Lock On” State

RETURN

handshaking without changing the status of Caps Lock switch.

SPACE

TAB

Caps Lock Release Control

Show 9 more labels / short text on this page
1-15 characters · 1-15 characters · MS None · MS None · None · Caps Lock Control · Record Suffix · Postamble · Preamble
Page 38 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Keyboard Interface Control
Page 38 · click to enlarge
Page 38

Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data

transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)

various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two

Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Keyboard Interface Control

♦ Delay Setting ♦

Interfunction Delay is a time delay between the transmission of each segment of the message string.

this selection automatically.

this selection automatically.

this selection automatically.

1-99 (x5) msec.

1-99 (x5) msec.

1-99 (x5) msec.

parameters.

Show 9 more labels / short text on this page
(2 digits) · (2 digits) · (2 digits) · MS None · MS None · MS None · Intermessage Delay · Intercharacter Delay · Interfunction Delay
Page 39 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Keyboard Interface Control
Page 39 · click to enlarge
Page 39

Enable numeric output as key pad (Num Lock On) output 0 1

0 1 2 3

♦ Emulation Setting & Upper/Lower Case Setting ♦

Keyboard Interface Control

SS Enable ASCII 00-31 code as keyboard function code output

Refer to Appendix – Keyboard Function Code Table for details.

Inverse case (change all characters output to inverse case)

Normal case (neglect the upper/lower case control)

Upper case (force all characters output as upper case)

Lower case (force all characters output as lower case)

SS Disable key pad emulation

Show 4 more labels / short text on this page
Ctrl-Output · Function Key Emulation · Key Pad Emulation · Upper/Lower Case
Page 40 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Serial Interface Control
Page 40 · click to enlarge
Page 40
Cino FuzzyScan Barcode Scanner (F700) — Serial Interface Control diagram (page 40)
Fig. 16 · Serial Interface Control

STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix

1 character 1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character 1 character

STX/ETX are two characters used to indicate the starting and ending of the total

♦ Record Suffix, Preamble ,Postamble Setting ♦

Maximum 15-character input; scan “FIN” to terminate this selection.

Maximum 15-character input; scan “FIN” to terminate this selection.

Serial Interface Control

Serial Interface Message String (RS232, USB COM) :

Show 4 more labels / short text on this page
STX/ETX Control · Record Suffix · Postamble · Preamble
Page 41 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Serial Interface Control
Page 41 · click to enlarge
Page 41

Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data

transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)

various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two

Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate

Serial Interface Control

♦ Delay Setting ♦

Interfunction Delay is a time delay between the transmission of each segment of the message string.

this selection automatically.

this selection automatically.

this selection automatically.

1-99 (x5) msec.

1-99 (x5) msec.

1-99 (x5) msec.

parameters.

Show 9 more labels / short text on this page
(2 digits) · (2 digits) · (2 digits) · MS None · MS None · MS None · Intermessage Delay · Intercharacter Delay · Interfunction Delay
Page 42 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Serial Interface Control
Page 42 · click to enlarge
Page 42

When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after

After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner

will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner

1. After preset NAK retry counts is received within the preset serial response time-out. 2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end. The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard

SS 3 times 0~255 times FIN

0 1 2 3

0 1 2 3

This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.

the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.

Serial Interface Control

♦ Protocol, ACK/NAK Setting ♦

each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.’

Enable ACK Time-out Indication

Disable ACK Time-out Indication

None (free running mode)

issues an error indication and discards the data under following two conditions:

Disable ACK Indication

Enable: There’s a specific LED and beeping indication for this setting.

Disable: There’s neither LED nor beeping indication for this setting.

USB COM doesn’t support RTS/CTS handshaking protocol.

NAK Retry Count

ACK Indication:

Show 8 more labels / short text on this page
(3 digits) · RTS/CTS (hardware handshaking) · ACK/NAK (software handshaking) · Xon/Xoff (software handshaking) · Enable ACK Indication · Handshaking Protocol · NAK Retry Count · ACK Indication
Page 43 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 2400 BPS 1200 BPS 57.6K BPS 115.2K BPS
Page 43 · click to enlarge
Page 43

When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data

The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.

6 7 8 9 A

B

4 5 8 9

8 9 A

B

D

E

0 1 2 3 4 5

0 1 2 3

0 1 2 3 4 5 6 7

♦Time Out Setting, Baud Rate, Data Frame ♦

Serial Interface Control

3 seconds 4 seconds 5 seconds 8 seconds 10 seconds 15 seconds

2400 BPS 1200 BPS 57.6K BPS 115.2K BPS

7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2

communication. This option is very helpful to ensure the reliability of data communication.

200 mseconds 500 mseconds 800 mseconds 1 second 2 seconds

38.4K BPS 19.2K BPS 9600 BPS 4800 BPS

8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1

Show 4 more labels / short text on this page
None · Serial Response Time-out · Baud Rate (BPS) · Data Frame
Page 44 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Wand/Laser Emulation Control
Page 44 · click to enlarge
Page 44

[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,

0 1 2 3 4

they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.

[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.

Wand/Laser Emulation Control

♦ Code 39/Code 128 Emulation ♦

Enable standard Code 39 skip emulation

Enable standard Code 39 replace emulation

Disable standard Code 39 emulation

Enable Full ASCII Code 39 emulation

Enable Code 128 emulation

Code 39/Code 128 Emulation

Page 45 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 45 · click to enlarge
Page 45

Low Power Mode (Low Power Triggering) The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation.

Trigger Mode (External Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner

Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is

similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work

Alternative Mode (Periodic Power Off) The scanner keeps the light source of the scanner turned on till the pre-defined light source on time is up. After the scanner turns

off the light source, you must press the trigger to turn on the light source again. After each good read, the timer counter of “Light Source on Time” is reset. You do not have

Flash Mode (Pulse Driven Reading) The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar

Force Mode (Continued Power On) The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for

Toggle Mode (Repeat Reading) The toggle mode is very similar to the Alternative Mode but without the pre-defined light source on time concern. You must press the

Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the

Level Mode (Auto Power Off) When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined

“Light Source on Time”. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press

the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after

Presentation Control When the scanner is placed on SmartStand, the scanner will be switched from hand-held scanning to hands free scanning automatically. Three

5 6 7 8

code, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.

properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “Presentation Sensitivity”).

0 1 2 3 4

trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again.

L680/L780 laser imagers don’t support:

Flash/ Force/ Toggle/ Diagnostic mode.

hands scanning modes are available. You are recommended to use flash mode or force mode while under insufficient ambient light.

Only Low power mode, Trigger mode, Presentation mode and Level mode are available for FuzzyScan Laser model.

scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.

♦ Operation Mode Setting ♦

Operation Control

L680/L780 laser imagers don’t support this function.

It is very helpful for mobile data collection and application, which are concerned with power saving.

to press the trigger frequently, it is very convenient for multiple scanning.

the pre-defined light source on time is up.

before scanning the bar code.

high speed bar code reading.

Show 14 more labels / short text on this page
Diagnostic mode · Toggle mode · Force mode · Level mode · Presentation mode · Trigger mode · Presentation mode · Low Power mode · Alternative mode · Flash mode · Force mode · Flash mode · Presentation Control · Operation Mode
Page 46 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 46 · click to enlarge
Page 46

0 1 2 3 4 5 6

♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦

Operation Control

Optional function, only available for vibrator model.

Buzzer tone - extremely high

Buzzer tone – medium

LED steady on

Buzzer tone – mute

Buzzer tone – high

Buzzer tone – low

Show 15 more labels / short text on this page
Enable 0 1 · Power-on beep · No power-on beep · Disable (LED off) · LED flash · Enable · Enable · SS Disable · Disable · SS Disable · Buzzer Tone Adjust · Power On Indicator · Good Read Indicator · Vibrator Control · Inverse Reading
Page 47 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 47 · click to enlarge
Page 47

Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on

0 1 2 3 4

0 1 2 3 4 5

♦ Dollar Sign, Redundancy, Scan Rate Control♦

Operation Control

The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.

To prevent potential miss reading.

Dollar sign output as “ $ “

Dollar sign output as “¥“

Dollar sign output as “ € “

Dollar sign output as “ £ “

Dollar sign output as “ ¢ “

the move. But this may impact to the reading distance.

Show 11 more labels / short text on this page
Fixed 0 1 · SS Dynamic · Level 1 · Level 2 · Level 3 · Level 4 · Level 5 · None · Dollar Sign Control · Scan Rate Control · Redundancy
Page 48 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 48 · click to enlarge
Page 48

The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification

0 1 2 3

0 1 2 3 4 5

0 1 2 3 4 5 6

♦ Flash Duty Cycle, Delay Setting ♦

Operation Control

L680/L780 laser imagers don’t support this function.

This Good Read Delay is the minimum amount of time before the imager can read another bar code.

The Flash Duty Cycle is designed to control the flashing frequency of the light source.

Immediate time out

1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle

200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.

will not allow reading of the same bar code twice.

(Double Scan Verification) SS

Show 9 more labels / short text on this page
Force verification · Short time out · Medium time out · Long time out · None · Disable · Flash Duty Cycle · Reread Delay · Good Read Delay
Page 49 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 49 · click to enlarge
Page 49

The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on

The Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode

when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any

The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity. This setting is only available for the scanner is in low

0 1 2 3

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4 5

♦ Time-out Setting, Good Read Duration ♦

till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.

Operation Control

trigger operation), the imager will revert to the original hands free mode.

1 sec 3 secs 5 secs 7 secs 9 secs Immediate

Time Delay to Low Power Mode

Light Source On Time

power mode.

Show 16 more labels / short text on this page
Long · Extremely long · Extremely short · Extremely long · Extremely long · Medium · Short · Short · Medium · Medium · Disable · Short · Long · Long · Hands Free Time-out · Good Read Duration
Page 50 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 50 · click to enlarge
Page 50

The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting

The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on

SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be

When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the

Enable 0 1

0 1 2 3 4

♦ Presentation Scanning Setting , Trigger Control♦

Operation Control

Only available for FuuzzyScan Laser model

Only available for FuzzyScan F460/F468

Enable left trigger, disable right trigger

Enable right trigger, disable left trigger

Enable left and right triggers

3 mins 5 mins 10 mins

SmartStand Power Off Timeout

off when the pre-defined duration is up.

the barcode.

SmartStand.

Show 11 more labels / short text on this page
Level 6 · Level 7 · Level 5 · SS Disable · Level 1 · Level 2 · Level 3 · Level 4 · Presentation Auto-sense · Presentation Sensitivity · Trigger Control
Page 51 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Control
Page 51 · click to enlarge
Page 51

Only available for L series laser imaging scanner.

Operation Control

♦ Laser Aiming Control♦

You can disable or enable laser aiming line when you scan PDF barcode.

Enable ◆ · SS Disable · Laser Aiming Control

Page 52 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Condensed DataWizard
Page 52 · click to enlarge
Page 52

DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,

you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help

Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done

A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with

If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.

[00-7F], [FIN]

[00-7F], [FIN]

0 1 2 3 4 5 6

♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦

Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.

Maximum 15-character input; scan “FIN” to terminate this selection.

Maximum 15-character input; scan “FIN” to terminate this selection.

If data length exceeds 99, 3-digit data length will be transmitted.

Condensed DataWizard

Enable both prefix and suffix AIM symbology ID transmission

Enable both prefix and suffix symbology ID transmission

you to arrange the transmission of scanned data to any specific format without software modification.

Enable prefix AIM symbology ID transmission

Enable suffix AIM symbology ID transmission

Disable symbology ID transmission

Enable prefix symbology ID transmission

Enable suffix symbology ID transmission

Enable 2 digits data length transmission

on-screen, under Windows 95/98/NT/2000/XP environment.

ease.

Show 9 more labels / short text on this page
1-15 characters · 1-15 characters · SS Disable · MS None · MS None · Symbology ID Transmission · Data Length Transmission · Postamble · Preamble
Page 53 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Condensed DataWizard
Page 53 · click to enlarge
Page 53

The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code

While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.

Cino FuzzyScan Barcode Scanner (F700) — Condensed DataWizard diagram (page 53)
Fig. 17 · Condensed DataWizard

Family Code Selection P.C Parameter Selection Option Code 2nd Option Code

symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.

Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.

Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 45 for details.

Condensed DataWizard

♦ Data Formatter Setting ♦

All of the above programmable parameters perform the same function depending on your setting.

Show 5 more labels / short text on this page
Formatter Control · 1st Insertion · 2nd Insertion · 3rd Insertion · 4th Insertion
Page 54 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Condensed DataWizard
Page 54 · click to enlarge
Page 54

All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the

Cino FuzzyScan Barcode Scanner (F700) — Condensed DataWizard diagram (page 54)
Fig. 18 · Condensed DataWizard

Family Code Selection P.C Parameter Selection Option Code 2nd Option Code

FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.

The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.

The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.

Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.

Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 45 for details.

Condensed DataWizard

♦ Data Verifier Setting ♦

Show 5 more labels / short text on this page
1st Identified Character · 2nd Identified Character · 3rd Identified Character · Identified Data Length · Verifier Control
Page 55 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Condensed DataWizard
Page 55 · click to enlarge
Page 55

The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code

All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it

Cino FuzzyScan Barcode Scanner (F700) — Condensed DataWizard diagram (page 55)
Fig. 19 · Condensed DataWizard

Family Code Selection P.C Parameter Selection Option Code 2nd Option Code

arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.

Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.

Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 45 for details.

Condensed DataWizard

♦ Data Replacer Setting ♦

symbologies for replacer control, and provides Multiple Position Replacement in the identified position.

Show 4 more labels / short text on this page
Replacer Control · 2nd Replacement · 3rd Replacement · 1st Replacement
Page 56 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Condensed DataWizard
Page 56 · click to enlarge
Page 56

The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code

symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data

While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record

Cino FuzzyScan Barcode Scanner (F700) — Condensed DataWizard diagram (page 56)
Fig. 20 · Condensed DataWizard

Family Code Selection P.C Parameter Selection Option Code 2nd Option Code

including or excluding the data of identification position. Please refer to the application example listed in page 45 for details.

Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 45 for details.

Condensed DataWizard

DS Transmitted data excluded the data of identified position

♦ Data Organizer Setting ♦

Please note that all “Character” input should be referred to the ASCII/HEX Table.

Suffix.

Show 4 more labels / short text on this page
Include/Exclude Control · Organizer Control · 2nd Organization · 1st Organization
Page 57 of the Cino FuzzyScan Barcode Scanner (F700) user manual — EAN-13 : 04
Page 57 · click to enlarge
Page 57

If your bar code label is a 16-digit Interleaved 2 of 5 which

includes the information of 6-digit date code, 6-digit serial

number and 4-digit unit price, you want the FuzzyScan do

Apply only Interleaved 2 of 5 to the condensed

Allow bar code output whose date code is leading with

The date code output should skip “9” and replaced it by

The unit price output should be skipped the first 2

Actual OutputA81025[TAB]SN123456[TAB]76[TAB]

following to calculate the actual position for identification.

If there is a 11-character data string, please refer to the

[Data Verifier, Data Replacer, Data Organizer]

The serial number output should be led with “SN”.

X

00 01 02 03 04 05 06 07 08 09 10

the following for you without software modification:

Check bar code is actually with 16-digit length.

Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6

Three outputs with “TAB” suffix.

Application Example Application Example Application Example Application Example

DataWizard.

digits.

“9”.

“A”.

You can select one or all types of bar code symbologies to

use Condensed DataWizard for advanced transmission

arrangement. If you scan “00” to select all types, the

FuzzyScan will arrange all incoming data to meet your

pre-defined format. If you want to select only one type bar

Cino FuzzyScan Barcode Scanner (F700) — [Data Verifier, Data Replacer, Data Organizer] diagram (page 57)
Fig. 21 · [Data Verifier, Data Replacer, Data Organizer]

If there is a 5-character input data string, refer to the following

code, please select one of the option code listed below.

00 01 02 03 04 05

X

to calculate the actual position for insertion:

Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology

Position Calculation Position Calculation Position Calculation Position Calculation

EAN-13 with 2 supple. : 34

EAN-13 with 5 supple. : 44

[Data Formatter]

UPC-A with 2 supple.: 32

UPC-A with 5 supple.: 42

UPC-E with 2 supple.: 33

UPC-E with 5 supple.: 43

UCC/EAN 128 : 31

Code 12801

EAN-13 : 04

UPC-A : 02

UPC-E : 03

Page 58 of the Cino FuzzyScan Barcode Scanner (F700) user manual — [Data Formatter]
Page 58 · click to enlarge
Page 58

Scan “Replacer Control” and set bar code symbology

Scan “1st Replacement” and set the identified position

to “00”, then replaced character to “41” (Hex Code of

Scan “Organizer Control” and set bar code symbology

Scan “1st Organization” and set the identified position

Scan “2nd Organization” and set the identified position

to “17”, then set the data transmission to “1”

Please note that Condensed DataWizard will follow the

So when you set the identified position in Data Organizer,

you must consider the inserted data which you already set

to “16”, then set the data transmission to “0” (forward).

Verifier Formatter Replacer Organizer

Scan “END” (Exit) to terminate the programming.

preset working flow as below:

[Important Notice]

[Data Organizer]

[Data Replacer]

via Data Formatter.

(backward).

to “48”.

to “48”.

A).

Scan “Verifier Control” and set bar code symbology to “48”

Scan “1st Identified Character” and set the identified

position to “00”, then set the identified character to “39”

Scan “Formatter Control” and set bar code symbology to

Scan 1st Insertion” and set the identified position to “06”,

then inserted characters to “09” (Hex Code of TAB), “53”

Scan “2nd Insertion” and set the identified position to “12”,

then inserted character to “09”. In the final, you must scan

Scan “3rd Insertion” and set the identified position to “16”,

then inserted character to “09”. In the final, you must scan

Scan “Identified Data Length” and set the length to “16”.

Scan “Program” to enter the programming mode.

“FIN” (Finish) code to terminate this selection.

“FIN” (Finish) code to terminate this selection.

(Hex Code of S), “4E” (Hex Code of N).

Programming Procedure Programming Procedure Programming Procedure Programming Procedure

(Interleaved 2 of 5).

(Hex Code of 9).

[Data Formatter]

[Data Verifier]

“48”.

Page 59 of the Cino FuzzyScan Barcode Scanner (F700) user manual — UPC
Page 59 · click to enlarge
Page 59

UPC-A m EAN/JAN-8 4

UPC-A with 2 supple. 1 EAN/JAN-8 with 2 supple. 1

UPC-E m EAN/JAN-13 m

UPC-E with 2 supple. 1 EAN/JAN-13 with 2 supple. 1

ExampleA EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is

Code 128 B m Code 93 Code 93 H G m Code 128

1 Code 11 Code 11 P H m

Codabar Codabar/NW-7 D F m MSI/Plessey MSI/Plessey R M m

Standard/Industrial 2 of 5 I S 0 UK/Plessey UK/Plessey S P 0

Matrix 2 of 5 K X 0 Telepen Telepen T B m

Composite Composite Code X e 0

China Postal Code L X 0 Code 39 G A m

German Postal Code M I 3 Code 39 Trioptic W X 0

Code 32 G A 0

UCC Coupon Code Z PDF417 PDF417/Micro PDF417 V L 0

Codablock Codablock F Y O 0

Korea Post Korea Post Code a X 0 UCC Coupon Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar

Cino ID AIM ID Cino ID AIM ID

N E

F E

code is transmitted as ]E09923456789019]C181010123451297 Remark: Above examples are given for the transmission of AIM ID.

Code Family Primary Format Code

transmitted as ]E449123562]E212345

2 EAN/JAN-8 with 5 supple.

2 EAN/JAN-13 with 5 supple.

Interleaved 2 of 5 J I m GS1 DataBar GS1 Databar

Each AIM Code Identifier contains the three-character string ]cm where:

EAN/JAN

ExampleA EAN-13 9923456789019 + GS1-128 81010123451297 bar
ExampleA UPC-A bar code 012345678950 with 2 supplement 12 is

IATA IATA O R m

code is transmitted as]E0512345678900]C181010123451297

E

GS1-128 C C

Code Family Primary Format Code

transmitted as ]E0012345678950]E112

A

E

Symbology ID Table

UPC-A with 5 supple.

UPC-E with 5 supple.

m = Modifier Character

c = Code Character

] = Flag Character

UPC

Show 13 more labels / short text on this page
Modified · Character · Character · Code · Character · Code 39 · Appendix · Modified · Character · Character · Code · Character · Code 25
Page 60 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Keyboard Function Code Table
Page 60 · click to enlarge
Page 60

To emulate the keyboard function key input for user definable parameters, user must configure actual content using the

Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done

by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,

COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.

Cino FuzzyScan Barcode Scanner (F700) — Keyboard Function Code Table diagram (page 60)
Fig. 22 · Keyboard Function Code Table

No. ANSI ASCII Key Function No. ANSI ASCII Key Function

07 BEL 07H F1 23 ETB 17H DEL (Delete) (Edit)

11 VT 0BH F3 27 ESC 1BH PAGE DOWN (Edit)

06 ACK 06H ESC 22 SYN 16H INS (Insert) (Edit)

10 LF 0AH F2 26 SUB 1AH PAGE UP (Edit)

08 BS 08H BACK SPACE 24 CAN 18H HOME (Edit)

13 CR 0DH ENTER (CR) 29 GS 1DH DOWN (Edit)

15 SI 0FH F6 31 US 1FH RIGHT (Edit)

09 HT 09H TAB 25 EM 19H END (Edit)

14 SO 0EH F5 30 RS 1EH LEFT (Edit)

12 FF 0CH F4 28 FS 1CH UP (Edit)

04 EOT 04H CAPS LOCK 20 DC4 14H F11

05 ENQ 05H NUM LOCK 21 NAK 15H F12

01 SOH 01H CTRL (Left) 17 DC1 11H F8

02 STX 02H ALT (Left) 18 DC2 12H F9

Keyboard Function Code Table

Appendix

Page 61 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Example:
Page 61 · click to enlarge
Page 61
Cino FuzzyScan Barcode Scanner (F700) — HEX/ASCII Reference Table diagram (page 61)
Fig. 23 · HEX/ASCII Reference Table

F SI US / ? O _ o DEL

L 0 1 2 3 4 5 6 7

0 NUL DLE SPACE 0 @ P ` p

1 SOH DC1 ! 1 A Q a q

2 STX DC2 " 2 B R b r

3 ETX DC3 # 3 C S c s

4 EOT DC4 $ 4 D T d t

5 ENQ NAK % 5 E U e u

6 ACK SYN & 6 F V f v

7 BEL ETB ' 7 G W g w

8 BS CAN ( 8 H X h x

9 HT EM ) 9 I Y i y

A LF SUB *J Z j z

B VT ESC + ; K [ k {

C FF FS , < L \ l |

D CR GS - = M ] m }

E SO RS . > N ^ n ~

ExampleASCII “A” → HEX “41”; ASCII “a” → “61”

HEX/ASCII Reference Table

: High Byte of HEX Value

: Low Byte of HEX Value

To configure the user definable parameters of FuzzyScan via

programming menu, FuzzyScan will ask you to scan your

desired ASCII value in HEX form. You have to refer to the

If you want the scanned data output leading with a Dollar

Sign, you have to set the “Preamble” to “$”. The configuration

Refer to the Hex/ASCII Table, you will find the HEX value

Scan the option code – 2 listed on the fold out back cover.

Scan the option code – 4 listed on the fold out back cover.

Scan the system command – FIN (Finish) to terminate

Scan the system command – End to exit the programming

Scan the system command – PROGRAM listed on page

Scan family code – PREAMBLE to select this family.

procedure is listed below for reference.

3-24 to enter programming mode.

ASCII Input Shortcut

“HEX/ASCII Table” for details.

mode for normal operation.

Preamble setting.

of “$” is 24.

Example:

Appendix

Page 62 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Host Interface Quick Set
Page 62 · click to enlarge
Page 62

RS232 Serial PS/2 (DOS/V) KBW Standard Mode

Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode

USB HID Standard Mode

USB HID Turbo Mode

USB Com Port Emulation

Host Interface Quick Set

Appendix

Page 63 of the Cino FuzzyScan Barcode Scanner (F700) user manual — Operation Mode Quick Set
Page 63 · click to enlarge
Page 63

Low Power (Low power trigger) Force (Continued power on)

Presentation (Auto sensing) Diagnostic (Test reading)

Trigger (External triggering) Toggle (Repeat reading)

Alternative (Periodic power off)

Flash (Pulse driven reading)

Level (Auto power off)

Operation Mode Quick Set

Appendix

Page 64 of the Cino FuzzyScan Barcode Scanner (F700) user manual — 5 D
Page 64 · click to enlarge
Page 64

5 D

6 E

7 F

2 A

3 B

Option Codes

END (Exit) · Appendix · FIN (Finish)

Page 65 of the Cino FuzzyScan Barcode Scanner (F700) user manual — END
Page 65 · click to enlarge
Page 65

Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface

Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation

User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and

(Enter Programming Mode) System Information List

FIN (Finish) PowerTool Host Link

(Exit Programming Mode) Factory Default

(SYSLIST)

Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.

would like to return to previous setting, please scan “User Default”.

Control, the rest of parameters will be returned to default value.

System Commands

END

Show 4 more labels / short text on this page
Master Default · Save User Default · User Default · Appendix
Page 66 of the Cino FuzzyScan Barcode Scanner (F700) user manual — www.cino.com.tw
Page 66 · click to enlarge
Page 66

www.cino.com.tw

FuzzyScan Family Programming Manual

CINO GROUP PC WORTH INT’L CO., LTD.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Cino FuzzyScan Barcode Scanner (F700)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Cino FuzzyScan Barcode Scanner (F700)

Be the first to ask — other owners or our team will answer.

Original document

Cino FuzzyScan Barcode Scanner (F700) manual PDF

66 pages·686 KB·Barcode Reader·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…