1 964.759.00.0 (00) Geberit T essera TM T oilet System INST ALLA TION INSTRUCTIONS Geberit Manufacturing, Inc. 1100 Boone Drive, Michigan City , IN 46360 www .us.geberit.com Phone: 219 / 879-4466 • Fax: 219 / 872-8003 For T echnical Assistance 800 / 225-7217 2100 Clearwater Drive, Des Plaines, IL 60018-5999 www .
2 Geberit T essera TM T oilet System Installation & Maintenance Instructions PRODUCT OVERVIEW The T essera TM in-wall T oilet System uses siphonic action to get the job done cleanly and effeciently with only 1.6 gal- lons per flush. The high density polyethylene tank is well insulated to prevent condensation.
3 Geberit T essera TM T oilet System Installation & Maintenance Instructions T ango 7" 180 14 1 / 2 " 368 F. F. F. F. x 3" – 75 3" – 75 19 3 /4 " 500 7 1 /8 " 180.
4 Geberit T essera TM T oilet System Installation & Maintenance Instructions F. F. R. H. RH = X plus 3" 3"(75) 3"(75) x 12" to 16" (305-407) T ANK & CARRIER INST ALLA TION IMPORT ANT! The finished Rim Height (RH) for the bowl must be determined prior to installing the carrier .
5 Geberit T essera TM T oilet System Installation & Maintenance Instructions 1. W ater supply specification, 1 / 2 ” copper - supply pressure 25 - 90 PSI. 2. Extend dr op ear elbow supply side with 1/2 ” x 6 ” copper nipple, secure elbow to cross brace (2 ” x 4 ” x 19 3 / 4 ” ) and install in back of the tank reset section.
6 Geberit T essera TM T oilet System Installation & Maintenance Instructions W ALL HUNG BOWL INST ALLA TION 4 Bevel the rough and sharp edges to pr event damage to the seal rings in the wall spigot ’ s. 1 2 3 1. Remove the plugs form the fill and dischar ge ope nings of tank & carrier assembly .
7 Geberit T essera TM T oilet System Installation & Maintenance Instructions W ALL HUNG BOWL INST ALLA TION 5 6 7 8 1. Remove clear plastic sleeves fom thr eaded rods. 2. Adjust r ods to protrude 3 ” fr om finished wall surface. 3. Secur e rods to carrier frame using hex nuts (provided).
8 Geberit T essera TM T oilet System Installation & Maintenance Instructions ACCESS P ANEL-FLUSH ACTUA TOR INST ALLA TION 6 1 3 1. Pur ge supply line, connect braided hose to stop valve. 2. Insert r efill tube into overflow funnel and fill tank with water .
9 Geberit T essera TM T oilet System Installation & Maintenance Instructions ACCESS P ANEL-FLUSH ACTUA TOR INST ALLA TION 8 1. Insert actuator push r od into rocker bushing so that taps are in contact with the actuator frame surface. 2. Install r od and tum clockwise to lock it into the bushing.
12 Geberit T essera TM T oilet System Installation & Maintenance Instructions CHICAGO F AUCETS WARRANTY / GEBERIT BRAND PRODUCT Geberit T essera TM T oilet System Chicago F aucets will either repl.
An important point after buying a device Chicago Faucets Plumbing Product (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chicago Faucets Plumbing Product yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chicago Faucets Plumbing Product - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chicago Faucets Plumbing Product you will learn all the available features of the product, as well as information on its operation. The information that you get Chicago Faucets Plumbing Product will certainly help you make a decision on the purchase.
If you already are a holder of Chicago Faucets Plumbing Product, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chicago Faucets Plumbing Product.
However, one of the most important roles played by the user manual is to help in solving problems with Chicago Faucets Plumbing Product. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chicago Faucets Plumbing Product along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center