Table of Contents 80 sections 3000 RATED Watts/3500 MAX. watts portable generator · certified for all states except california · Model 65414 · Set up, Operating, and Servicing · … ShowHide
3000 RATED Watts/3500 MAX. watts portable generatorp.1certified for all states except californiap.1Model 65414p.1Set up, Operating, and Servicingp.1Instructionsp.1Visit our website at: http://www.harborfreight.comp.1Every 300 Operationp.2Contentsp.2Hours:16p.2Important SAFETYp.2Storage16p.2Information3p.2Engine Troubleshooting18p.2Extension Cords7p.2Equipmentp.2Troubleshooting 20p.2Basic Specifications8p.2Functions8p.2Main Parts List21p.2Unpacking8p.2Diagram22p.2Parts List and Diagram A -p.2CONTROLS9p.2Crankcase Assembly23p.2Operating Instructions10p.2Parts List and Diagram B -p.2Cylinder Head Assembly24p.2Starting the Engine10p.2Checking and Fillingp.2Parts List and Diagramp.2Engine Oil10 Checking and Filling Fuel11 Start Procedure11 Break-in Period12p.2C - Crankshaft, Piston, Connecting Rod, Camshaft and Flywheel Assemblies25p.2Equipment Operation12p.2D - Recoil Starter and Ignition Coil Assembly26p.2Control Panel Features13p.2Parts List and Diagram E -p.2Technical Specifications14p.2Air Cleaner and Muffler Assembly27p.2Servicing14p.2Parts List and Diagram F -p.2Maintenance Procedures14p.2Engine Oil Change14 Air Filter Elementp.2Fuel Supply System27p.2Parts List and Diagram G -p.2Maintenance14 Spark Plug Maintenance15p.2Starter and Generator Assembly28p.2Cleaning, Maintenance, andp.2Wiring Diagram29p.2Lubrication Schedule16p.2Limited 1 year / 90 Dayp.2After Initial 20p.2warranty30p.2Operation Hour Period:16 Every 25 Operationp.2Emission Control Systemp.2Hours Thereafter:16 Every 50 Operationp.2Hours:16 Every 100 Operationp.2Save This Manualp.3Informationp.3SAVE THESE INSTRUCTIONSp.3Set up precautionsp.3Operating precautionsp.4AC APPLICATIONSp.6Service precautionsp.6Save thesep.6Extension Cordsp.7Basic Specificationsp.8Functionsp.8REMOVE THESE BOLTS AND BRACKETS BEFORE USE!p.8CONTROLSp.9Power Indicator Light AC Circuit Breaker Switchp.9Engine Power Switchp.9MAIN BREAKERp.9120V AC OUTLETS ONLYp.920A RESETp.9120 V~ Duplex Receptaclep.9AC Resetp.912 VDC Outletp.9Ground Wirep.9Switchp.9Connectionp.9
Page 1 of the Chicago Electric 65414 user manual — Visit our website at: http://www.harborfreight.com
Page 1 · click to enlarge
Page 1

3000 RATED Watts/3500 MAX. watts portable generator

certified for all states except california

Model 65414

Set up, Operating, and Servicing

Instructions

Chicago Electric 65414 — certified for all states except california diagram (page 1)
Fig. 1 · certified for all states except california

Using an engine indoors CAN KILL YOU IN MINUTES.

Engine exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

Visit our website at: http://www.harborfreight.com

Read this material before using this product.

Failure to do so can result in serious injury. Save this manual.

Copyright© 2009 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.

For technical questions or replacement parts, please call 1-800-444-3353.

· Manual Revised 09j

Page 2 of the Chicago Electric 65414 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

3000 RATED Watts/3500 MAX. watts portable generatorp.1certified for all states except californiap.1Model 65414p.1Set up, Operating, and Servicingp.1Instructionsp.1Visit our website at: http://www.harborfreight.comp.1Every 300 Operationp.2Contentsp.2Hours:16p.2Important SAFETYp.2Storage16p.2Information3p.2Engine Troubleshooting18p.2Extension Cords7p.2Equipmentp.2Troubleshooting 20p.2Basic Specifications8p.2Functions8p.2Main Parts List21p.2Unpacking8p.2Diagram22p.2Parts List and Diagram A -p.2CONTROLS9p.2Crankcase Assembly23p.2Operating Instructions10p.2Parts List and Diagram B -p.2Cylinder Head Assembly24p.2Starting the Engine10p.2Checking and Fillingp.2Parts List and Diagramp.2Engine Oil10 Checking and Filling Fuel11 Start Procedure11 Break-in Period12p.2C - Crankshaft, Piston, Connecting Rod, Camshaft and Flywheel Assemblies25p.2Equipment Operation12p.2D - Recoil Starter and Ignition Coil Assembly26p.2Control Panel Features13p.2Parts List and Diagram E -p.2Technical Specifications14p.2Air Cleaner and Muffler Assembly27p.2Servicing14p.2Parts List and Diagram F -p.2Maintenance Procedures14p.2Engine Oil Change14 Air Filter Elementp.2Fuel Supply System27p.2Parts List and Diagram G -p.2Maintenance14 Spark Plug Maintenance15p.2Starter and Generator Assembly28p.2Cleaning, Maintenance, andp.2Wiring Diagram29p.2Lubrication Schedule16p.2Limited 1 year / 90 Dayp.2After Initial 20p.2warranty30p.2Operation Hour Period:16 Every 25 Operationp.2Emission Control Systemp.2Hours Thereafter:16 Every 50 Operationp.2Hours:16 Every 100 Operationp.2Save This Manualp.3Informationp.3SAVE THESE INSTRUCTIONSp.3Set up precautionsp.3Operating precautionsp.4AC APPLICATIONSp.6Service precautionsp.6Save thesep.6Extension Cordsp.7Basic Specificationsp.8Functionsp.8REMOVE THESE BOLTS AND BRACKETS BEFORE USE!p.8CONTROLSp.9Power Indicator Light AC Circuit Breaker Switchp.9Engine Power Switchp.9MAIN BREAKERp.9120V AC OUTLETS ONLYp.920A RESETp.9120 V~ Duplex Receptaclep.9AC Resetp.912 VDC Outletp.9Ground Wirep.9Switchp.9Connectionp.9
Page 3 of the Chicago Electric 65414 user manual — SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

Save This Manual

Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.

Important SAFETY

Information

In this manual, on the labeling, and all other information provided with this product:

Failure to follow all instructions listed below may result in fire, serious injury and/or DEATH. The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

SAVE THESE INSTRUCTIONS

Set up precautions

Gasoline fuel and fumes are 1. flammable, and potentially explosive. Use proper fuel storage and handling procedures. Do not store fuel or other flammable materials nearby.

Have multiple ABC class fire 2. extinguishers nearby.

Operation of this equipment may 3. create sparks that can start fires around dry vegetation.

Page 4 of the Chicago Electric 65414 user manual — Operating precautions
Page 4 · click to enlarge
Page 4

A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.

Keep children away from the equipment, 2. especially while it is operating.

Do not leave the equipment unattended 3. when it is running. Turn off the equipment (and remove safety keys, if available) before leaving the work area.

Set up and use only on a flat, level, 4. well-ventilated surface.

Wear ANSI-approved safety goggles and 4. hearing protection during use.

Wear ANSI-approved safety goggles, 5. heavy-duty work gloves, and dust mask/respirator during set up and use.

People with pacemakers should 5. consult their physician(s) before use. Electromagnetic fields in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure. Caution is necessary when near the engine’s magneto or recoil starter.

Use only oil and fuel recommended 6. in the “Specifications” section of this manual.

Use only accessories that are 6. recommended by Harbor Freight Tools for your model. Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment.

Operating precautions

1. Carbon Monoxide Hazard Using an engine indoors CAN KILL YOU IN MINUTES. Engine exhaust contains carbon monoxide. This is a poison you cannot see or smell.

Do not operate in explosive 7. atmospheres, such as in the presence of flammable liquids, gases, or dust. Gasoline-powered engines may ignite the dust or fumes.

Stay alert, watch what you are doing 8. and use common sense when operating this piece of equipment. Do not use this piece of equipment while tired or under the influence of drugs, alcohol or medication.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Do not overreach. Keep proper footing 9. and balance at all times. This enables better control of the equipment in unexpected situations.

Dress properly. Do not wear loose 10. clothing or jewelry. Keep hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.

Only use OUTSIDE and far away from windows, doors, and vents.

Page 5 of the Chicago Electric 65414 user manual — Operating precautions
Page 5 · click to enlarge
Page 5

Parts, especially exhaust system 11. components, get very hot during use. Stay clear of hot parts.

equipment and do not use the equipment for a purpose for which it is not intended.

Do not cover the engine or equipment 12. during operation.

Keep the equipment, engine, and 13. surrounding area clean at all times.

Use the equipment, accessories, etc., in 14. accordance with these instructions and in the manner intended for the particular type of equipment, taking into account the working conditions and the work to be performed. Use of the equipment for operations different from those intended could result in a hazardous situation.

If the plugged in product operates abnormally or unusually slow, immediately stop using the generator as a power source. Always read and adhere to the instruction manual of the product to be powered, to make sure that it can be safely and efficiently powered by a portable generator.

Do not operate the equipment with 15. known leaks in the engine’s fuel system.

This product contains or, when used, 16. produces a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.)

Connections for standby power to a building electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

When spills of fuel or oil occur, they must 17. be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state, or federal codes and regulations. Store oil rags in a bottom- ventilated, covered, metal container.

Keep hands and feet away from moving 18. parts. Do not reach over or across equipment while operating.

Before use, check for misalignment 19. or binding of moving parts, breakage of parts, and any other condition that may affect the equipment’s operation. If damaged, have the equipment serviced before using. Many accidents are caused by poorly maintained equipment.

*Sensitive electronic equipment includes, but is not limited to, audio/ video equipment, some television sets, computers, and printers.

Use the correct equipment for the 20. application. Do not modify the

Page 6 of the Chicago Electric 65414 user manual — Save these
Page 6 · click to enlarge
Page 6

AC APPLICATIONS

Do not alter or adjust any part of the 3. equipment or its engine that is sealed by the manufacturer or distributor. Only a qualified service technician may adjust parts that may increase or decrease governed engine speed.

Before connecting an appliance or 1. power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock.

W 4. ear ANSI-approved safety goggles, heavy-duty work gloves, and dust mask/ respirator during service.

If an appliance begins to operate 2. abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded.

Maintain labels and nameplates on 5. the equipment. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement.

Make sure that the electrical rating of 3. the tool or appliance does not exceed that of the generator. Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30 minutes.

Have the equipment serviced by a 6. qualified repair person using only identical replacement parts. This will ensure that the safety of the equipment is maintained. Do not attempt any service or maintenance procedures not explained in this manual or any procedures that you are uncertain about your ability to perform safely or correctly.

Substantial overloading will open the 4. circuit breaker. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker or circuit protector OFF, but will shorten the service life of the generator.

Store equipment out of the reach of 7. children.

Follow scheduled engine and equipment 8. maintenance.

Refueling Precautions: 9.

Service precautions

Do not smoke, or allow sparks, flames, a.

or other sources of ignition around the equipment, especially when refuelling.

Before service, maintenance, or 1. cleaning:

Do not refill the fuel tank while the b.

Turn the engine switch to its “OFF” a.

engine is running or hot.

position.

Do not fill fuel tank to the top. Leave c.

Allow the engine to completely cool. b.

a little room for the fuel to expand as needed.

Then, remove the spark plug wire(s) c.

from the spark plug(s).

Refuel in a well-ventilated area only. d.

Keep all safety guards in place and in 2. proper working order. Safety guards include muffler, air cleaner, mechanical guards, and heat shields, among other guards.

Save these

instructions.

Page 7 of the Chicago Electric 65414 user manual — Extension Cords
Page 7 · click to enlarge
Page 7

If you are using one extension cord 5. for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

Extension Cords

Grounded 1. tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

As the distance from the supply 2. outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. (See Table A.)

If you are using an extension cord 6. outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

Make sure the extension cord is 7. properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

The smaller the gauge number of the 3. wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

Protect the extension cords from 8. sharp objects, excessive heat, and damp or wet areas.

When using more than one extension 4. cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

Chicago Electric 65414 — Extension Cords diagram (page 7)
Fig. 2 · Extension Cords
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT) NAMEPLATE AMPERES (at full load)EXTENSION CORD LENGTH 25 Feet50 Feet75 Feet100 Feet150 Feet 0 – 2.01818181816 2.1 – 3.41818181614 3.5 – 5.01818161412 5.1 – 7.01816141212 7.1 – 12.018141210- 12.1 – 16.0141210-- 16.1 – 20.01210--- TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
Page 8 of the Chicago Electric 65414 user manual — REMOVE THESE BOLTS AND BRACKETS BEFORE USE!
Page 8 · click to enlarge
Page 8

Basic Specifications

Functions

Chicago Electric 65414 — Functions diagram (page 8)
Fig. 3 · Functions

This unit can power items such as the following:

FuelType91+ octane premium unleaded gasoline Capacity4 Gallons Engine OilTypeSAE 10W-30 above 32°F SAE 5W-30 at 32°F or below Capacity2/3 Quart; Low Oil Shutdown Sensor Spark Plug Gap0.030” Run Time @ 50% Load9 Hours with full tank Engine Type6.5 HP Four-stroke Overhead Valve Design IgnitionRecoil Start with Electronic Ignition Electrical PlugsOne 20A duplex NEMA 120V~receptacle One 25A NEMA 120V 3 prong twist lock receptacle One T-Type 12V outlet
ITEMRUNNING WATTSSTART-UP WATTS Belt Sander12002400 Refrigerator/Freezer7002200 1/2 HP Sump Pump10502150 1/2 HP Well Pump10002100 Miter Saw16503000 1-1/2 HP Capacitor Start & Run Motor14003100

Check nameplate wattages on all loads before connecting to generator.

When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at 1-800-444- 3353 as soon as possible.

in the Technical Engine Specifications chart in this manual.

Chicago Electric 65414 — Functions diagram (page 8)
Fig. 4 · Functions

The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental Protection Agency. For warranty information, refer to the last pages of this manual.

At high altitudes, the engine’s carburetor, governor (if so equipped), and any other parts that control the fuel-air ratio will need to be adjusted by a qualified mechanic to allow efficient high-altitude use and to prevent damage to the engine and any other devices used with this product.

REMOVE THESE BOLTS AND BRACKETS BEFORE USE!

There are two metal brackets that secure the generator to the bottom of the crate. These brackets hold the generator in place during shipment to prevent damage. They must be removed before use. See the photo above.

Page 9 of the Chicago Electric 65414 user manual — MAIN BREAKER
Page 9 · click to enlarge
Page 9

CONTROLS

Power Indicator Light AC Circuit Breaker Switch

Engine Power Switch

Chicago Electric 65414 — Power Indicator Light AC Circuit Breaker Switch diagram (page 9)
Fig. 5 · Power Indicator Light AC Circuit Breaker Switch

MAIN BREAKER

120V AC OUTLETS ONLY

20A RESET

120 V~ Duplex Receptacle

AC Reset

12 VDC Outlet

Ground Wire

Switch

Connection

120 V~ Twist Lock Receptacle

DC Circuit Breaker Switch

120V Duplex Receptacle for 15A or 20A

Show 5 more labels / short text on this page
Plug for up · to 15A · Plug for up · to 20A · plugs
Page 10 of the Chicago Electric 65414 user manual — Checking and Filling Engine Oil
Page 10 · click to enlarge
Page 10

low engine oil WILL permanently damage the engine. Check the oil level with the engine stopped and in a level position.

Operating Instructions

Read the entire Important

Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Wipe dipstick exterior with a clean 1. cloth. Remove the dipstick and wipe it off with a clean rag. Pour engine oil into the oil fill hole until the level of oil is even with the bottom edge of the oil fill hole (if you cannot see the oil through the oil fill hole, then the oil is too low and more oil must be added).

To prevent serious injury: Operate only with proper spark arrestor installed. Operation of this equipment may create sparks that can start fires around dry vegetation. A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.

Reinsert the dipstick into the oil 2. filler neck, but do not screw in, then remove it to check the oil level. The oil level should reach the upper limit (H) mark on the dipstick (bottom edge of the oil fill hole).

If the oil level is not to the upper limit 3. mark (bottom edge of the oil fill hole), add the appropriate type of oil until the oil level reaches the upper limit mark.

Starting the Engine

Inspect engine and equipment

THIS GENERATOR HAS AN AUTO-SHUTDOWN OIL SENSOR. IF ENGINE STOPS OR WILL NOT START, CHECK OIL LEVEL.

looking for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly. Before starting, first familiarize yourself with proper shut down and emergency shut down procedures.

Chicago Electric 65414 — Starting the Engine diagram (page 10)
Fig. 6 · Starting the Engine

Engine Oil SAE 10W-30 above 32°F SAE 5W-30 at 32°F or below

Checking and Filling Engine Oil

Replace the Oil Dipstick. 4.

The Oil Sensor will automatically shut down the engine before the oil level falls below the safe/low limit. To avoid nuisance tripping of the Oil Sensor and damage to property, check that the oil level is at the

engine’s crankcase is not properly filled with oil before each use. Before each use, check the oil level. Do not run the engine with low or no engine oil. Running the engine with no or

Page 11 of the Chicago Electric 65414 user manual — Start Procedure
Page 11 · click to enlarge
Page 11

bottom edge of the oil fill hole before each start-up.

Fill the engine with the b.

proper amount and type of fuel and oil. Read the Equipment c.

low oil or no oil; the engine will be permanently damaged.

Operation section that follows.

Checking and Filling Fuel

Unplug loads from the Generator and 1. make sure the AC Circuit Breaker Switch is in the OFF position before starting to prevent permanent generator damage.

Check the fuel level. If the fuel level 1. is more than 1” below the fill neck of the fuel tank, add more fuel.

Turn the engine fuel valve to its ON 2. or OPEN position.

Turn the engine power switch to its 3. ON or RUN position.

Then, turn the engine choke lever to 4. its “CHOKE” position. Set the choke lever in the “RUN” position when starting a warm engine.

To fill the Fuel Tank, first wipe off the 2. Fuel Tank Cap and the surrounding area.

Grasp the starter handle, and pull 5. slowly until resistance is felt. While holding the handle, allow the starter rope to rewind. Then, pull the starter handle with a rapid, full arm stroke. Once again while holding the handle, allow the rope to rewind. Repeat as necessary, until the engine starts.

Unscrew, and remove the Fuel Tank 3. Cap.

Mix fuel stabilizer (not included) 4. with 91 octane (or better) premium unleaded gasoline according to fuel stabilizer directions.

After the engine starts and warms 6. up, slowly move the choke lever to its “RUN” position.

gasoline.

Fill the Fuel Tank to about 1 inch 5. under the fill neck of the gasoline tank with the stabilized unleaded gasoline mixture.

no load until warm (1-5 minutes) to stabilize.

Then replace the Fuel Tank Cap. 6.

Move the AC Circuit Breaker Switch 7. to its ON or RUN position.

Start Procedure

Before starting the engine:

Inspect the equipment and a.

engine.

Page 12 of the Chicago Electric 65414 user manual — Equipment Operation
Page 12 · click to enlarge
Page 12

Break-in Period

Make sure your generator is properly 1. grounded to avoid electrical shocks. Connect a 10 gauge or larger insulated copper wire to the Ground Connection on the Control Panel. Connect this wire to a suitable external ground, such as a metal stake in the ground.

Breaking-in the engine will help 1. to ensure proper equipment and engine operation, and will extend the engine’s lifespan. The warranty is void if the engine is not broken in properly. The first 20 hours of operation is the break-in period.

Don’t overload the generator. The 2. total wattage used by the appliances should be less than the output rating of the generator. If you put too many appliances on the generator, it could seriously damage the appliances and electronics. Overloading the generator could also cause fires in the power cord. This generator is rated at 3000 / 3500 Watts.

During the first 3 hours of use: 2.

Do not apply a heavy load to the • equipment.

After the first 20 hours of use: 3.

Change the engine oil. •

Under normal operating conditions subsequent maintenance follows the schedule explained in the Maintenance and Servicing section.

power in a surge than they do during continuous operation. When figur ing total wattage of all appliances connected to this generator, use the higher start-up amperage rating of each appliance.

Equipment Operation

To prevent serious injury and death: DO NOT CONNECT GENERATOR directly TO HOUSEHOLD WIRING. A portable electric generator that is connected to your household wiring without a proper cut off switch can ‘back feed’ into the power lines connected to your home. Power created by your generator can injure or even kill a utility lineman making outage repairs many miles away. Only a certified electrician can safely connect the generator to your home’s wiring.

Do not exceed the current limit 3. specified for any one receptacle.

Move the AC Circuit Breaker switch 4. to the ON position.

Plug in your extension cord or 5. appliance.

Be sure that all appliances are in 6. good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the AC Circuit Breaker and the generator Engine Power Switch immediately. Then disconnect the appliance and examine it for signs of malfunction.

Page 13 of the Chicago Electric 65414 user manual — Control Panel Features
Page 13 · click to enlarge
Page 13

AC Circuit Breaker Switch protects 3. circuits when using AC power.

AC Circuit Breaker to switch off, reduce the electrical load on the circuit and wait a few minutes before resetting the circuit breaker.

120 V~ duplex outlet provides two 4. grounded outlets for standard 110- 120 V~ household appliances. The outlets are configured for both standard 15A plugs or 20A plugs - See Figure 1 “Controls”.

The DC terminal may be used 7. to operate 12 Volt DC portable appliances only. CAUTION! Do not use this generator to charge 12VDC batteries. Directly charging a 12 Volt battery may cause the battery to overheat and possibly explode. CAUTION: Do not attempt to start an automobile engine with this generator. Voltage back feed from the alternator may damage the generator.

120 V~ twist lock receptacle provides 5. a grounded outlet for one 120 Volt appliance, such as a water heater.

12 VDC outlet provides a power 6. source for 12 volt DC items, such as automotive accessories. 12 VDC Circuit Breaker Switch provides circuit protection for 12 VDC accessories.

while the AC power is in use. An overloaded DC circuit will trip the DC circuit protector (push button comes out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation.

Disconnect all loads from the 8. generator before shutting off. To prevent accidents, turn off the engine and disconnect its spark plug wire after use. Wait for the engine to cool, clean external parts with clean cloth, then store the equipment out of children’s reach according to the Storage instructions in this manual.

Control Panel Features

Engine Power Switch must be in ON 1. position for engine to start and run. Move to OFF position to stop engine.

Power Indicator Light, when lit, 2. shows that the generator is producing electrical energy.

Page 14 of the Chicago Electric 65414 user manual — Air Filter Element Maintenance
Page 14 · click to enlarge
Page 14

Technical Specifications

Maintenance Procedures

Many maintenance procedures,

including those not detailed in this manual, will need to be performed by a qualified technician for safety. If you have any doubts about your ability to safely service the equipment or engine, have a qualified technician service the equipment instead.

Engine Type 4 Stroke, OHV Bore x Stroke 68 x 54mm Compression Ratio 8.5:1 Displacement 196cc

Fuel Type 91+ octane premium unleaded gasoline Capacity 4 Gallons

SAE10W-30 above 32° F SAE 5W-30 at 32° F or below Capacity 2/3 Quarts

maintenance and servicing procedures are not followed.

NGK BP61S Bosch W6DC Champion N11YC Gap 0.030”

Engine Oil Change

Intake 0.1mm Exhaust 0.15mm Speed 3600 RPM

operation and can cause burns. Wait for engine to cool before changing oil.

Servicing

Place a drain pan (not included) 1. underneath the crankcase’s drain plug.

To prevent serious injury from accidental starting: Turn the Power Switch of the equipment to its “OFF” position, wait for the engine to cool, and disconnect the spark plug wire(s) before performing any inspection, maintenance, or cleaning procedures.

Remove the Drain Plug (1a) and, if 2. possible, tilt the crankcase slightly to help drain the oil out. Recycle used oil.

If the Drain Plug Washer (2a) is 3. damaged, replace with a new Washer.

Re-install the Drain Plug and tighten 4. it in place.

Refill the oil to the proper level 5. following the instructions under the Starting the Engine section.

To prevent serious injury from equipment failure: Do not use damaged equipment. If abnormal noise, vibration, or excess smoking occurs, have the problem corrected before further use.

Air Filter Element Maintenance

Wipe off the air cleaner cover. 1.

Show 4 more labels / short text on this page
Engine Oil Type · Compatible Types · Spark Plug · Valve Clearance
Page 15 of the Chicago Electric 65414 user manual — Spark Plug Maintenance
Page 15 · click to enlarge
Page 15

The air cleaner cover is held in place 2. by clamps. Remove the clamps and the cover.

Gasket-style: Finger-tighten until the gasket contacts the cylinder head, then about 1/2-2/3 turn more. Non-gasket-style: Finger-tighten until the plug contacts the head, then about 1/16 turn more.

Remove the air filter element. 3.

Cleaning: 4.

There are two foam filter elements. a.

Apply dielectric spark plug boot 6. protector (not included) to the end of the spark plug and reattach the wire securely.

Wash them in warm water and mild liquid soap several times. Rinse. Squeeze out excess water and allow it to dry completely.

Soak the filter in lightweight oil b.

briefly, then squeeze out the excess oil.

Install the new filter or the cleaned 5. filter. Secure the Air Cleaner Cover before use.

Spark Plug Maintenance

Disconnect spark plug wire from 1. end of plug. Clean out debris from around spark plug.

Using a spark plug wrench, remove 2. the spark plug.

Inspect the spark plug: 3. If the electrode is oily, clean it using a clean, dry rag. If the electrode has deposits on it, polish it using emery paper. If the white insulator is cracked or chipped, the spark plug needs to be replaced.

When installing a new spark 4. plug, adjust the plug’s gap to the specification on the Technical specification chart. Do not pry against the electrode or the insulator, the spark plug can be damaged.

Install the new spark plug or the 5. cleaned spark plug into the engine.

Page 16 of the Chicago Electric 65414 user manual — Every 100 Operation Hours:
Page 16 · click to enlarge
Page 16

Every 300 Operation Hours:

Cleaning, Maintenance, and

Lubrication Schedule

Clean fuel tank and carburetor. a.

Clean carbon build-up from b.

combustion chamber.

is intended solely as a general guide. If performance decreases or if equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors.

Check oil tube condition and replace c.

as needed.

Storage

Wait for engine to cool, then clean 1. engine with clean cloth.

When the equipment is to remain idle 2. for longer than 20 days, prepare the engine for storage as follows:

the regular checks and maintenance explained as part of the regular operation of the engine and equipment.

Change engine oil and empty fuel a.

tank.

Either leave fuel tank empty or b.

refill fuel tank with fresh unleaded gasoline mixed with a fuel stabilizer intended for long term engine storage (not included). After filling, run engine for about 5-10 minutes to circulate the treated gasoline through the carburetor. Wait for engine to cool before proceeding.

After Initial 20 Operation Hour Period:

Change engine oil. a.

Every 25 Operation Hours Thereafter:

Clean/replace air filter element. a.

Inspect/clean spark plug. b.

Every 50 Operation Hours:

Clean out area around spark plug. c.

Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole.

Change engine oil. a.

Replace fuel filter (if equipped). b.

Check spark plug. Clean and re-gap c.

Reinstall spark plug, but leave spark d.

as needed.

plug wire disconnected.

Pull recoil starter to distribute oil e.

Every 100 Operation Hours:

in cylinder. Stop after one or two revolutions when you feel the piston start the compression stroke (when you start to feel resistance).

Replace spark plug. a.

Replace air filter element. b.

Clean fuel tank and fuel strainer. c.

Disconnect battery cables (if f.

equipped).

scheduled for 25, 50, and 100 operation hours should be performed at least yearly.

Apply a thin coat of rust preventive oil 3. to all uncoated metal parts.

Page 17 of the Chicago Electric 65414 user manual — CONTROLS
Page 17 · click to enlarge
Page 17

Cover and store in a dry, well- 4. ventilated area out of reach of children.

Before starting the engine after 5. storage, keep in mind that untreated gasoline will deteriorate quickly.

Place a container below the carbure a.

tor bowl and drain the fuel from the fuel tank and carburetor bowl.

Discard the drained fuel properly as b.

per local ordinance.

Change to fresh fuel if untreated c.

gasoline has been sitting for a month, if treated gasoline has been sitting beyond the fuel stabilizer’s recommended time period, or if the engine does not start properly.

Page 18 of the Chicago Electric 65414 user manual — Engine System Possible Cause Possible Solution
Page 18 · click to enlarge
Page 18

Engine Troubleshooting

Problem: Low power output. Engine bogs down or stops under load. Excess exhaust or unburned fuel in exhaust. See chart below:

Engine System Possible Cause Possible Solution

Ignition System Incorrect Ignition Timing. Adjust Engine Advance Angle.

Fuel Supply System Air in fuel line or fuel line clogged. 1. Main Jet not adjusted properly. 2. Metering Jet or Main Jet clogged. 3. Fuel Cock clogged. 4. Carbon Fouling in Combustion 5. Chamber. Clogged Air Filter. 6. Intake Manifold leaking. 7.

Purge air or clear obstruction. 1. Readjust Main Jet. 2. Clean and Readjust. 3. Clean as needed. 4. Clean out Combustion Chamber. 5.

Clean or replace Air Filter. 6. Repair or replace as needed. 7. Poor Compression Worn Piston, Piston Ring or 1. Cylinder Wall.

Check compression and wear 1. tolerances, repair or replace as needed. Check compression, replace as 2. needed. Check wear tolerances, repair or 3. replace as needed.

Leaking Cylinder Head Gasket. 2.

Worn Valves, Valve Seats, Stems 3. or Valve Guides.

ProblemEngine does not start or does not run smoothly. See chart below:

Symptom Possible Cause Possible Solution Engine is Pinging Excess wear of:

Check wear, replace as needed.

  • Piston, Cylinder Wall or Rings.
  • Piston Pin or Piston Pin Hole.
  • Connecting Rod Wrist Pin.
  • Crankshaft Roller Bearing.

Abnormal Com bustion or engine running hot or excess smoking.

Clean out Combustion chamber and 1. spark plug. Drain gas, clean out fuel filter and 2. replace with fresh gas, minimum 91 octane premium unleaded gasoline. Engine does not start.

Combustion chamber carbon 1. fouling. Dirty or old gasoline or oil in gas. 2.

Engine Switch in OFF position. 1. Water in Carburetor Bowl. 2.

Move Switch to ON position. 1. Drain carburetor Bowl, clean Fuel 2. Filter. Clean and re-gap plug at 0.030”. 3. Replace plug if needed. Check timing and adjust. 4. Check for damaged wires, test output. 5. Check oil level, top off as needed. 6.

Spark Plug gap not correct. 3.

Incorrect Ignition Timing. 4. Damaged coil or ignition wires. 5. Low Oil level. 6.

Page 19 of the Chicago Electric 65414 user manual — CONTROLS
Page 19 · click to enlarge
Page 19

Engine not run ning Smoothly

Poor Fuel quality. 1.

Replace fuel with 91+ octane premium 1. unleaded gasoline. Adjust the choke. 2. Have the timing checked by a qualified 3. technician.

Incorrect choke setting. 2. Incorrect Timing. 3.

ProblemEngine stops suddenly while running. See chart below:

Engine System Possible Cause Possible Solution Fuel Supply System

Check fuel level and refill as needed. 1. Clean Fuel Filter. 2. Replace if needed. 3. Clean and readjust. 4. Ignition System Engine Switch is in OFF position. 1. Spark Plug tip is burned through 2. or carbon fouled. Spark Plug Wire is disconnected. 3. Spark Plug wire is shorting against 4. engine body or frame. Ignition Coil is shorted or 5. damaged.

Fuel is used up. 1. Fuel Filter is clogged. 2. Carburetor Float is leaking. 3. Needle Valve sticks. 4.

Move Switch to ON position. 1. Clean or replace spark plug. Reset 2. gap to 0.030”. Check connections at both ends. 3. Check condition of spark plug wire, 4. replace as needed. Check coil continuity and output. 5.

Engine Piston, Piston Rod, Valve 1. or Crankshaft may be damaged. Generator Shaft may be seized. 2.

Have serviced by a qualified 1. technician. Disconnect engine and attempt to 2. rotate generator shaft by hand. Repair or replace as needed.

ProblemEngine runs excessively hot. See chart below:

Problem Possible Cause Possible Solution Engine runs excessively hot

Improper Ignition Timing. 1. Exhaust manifold, muffler or exhaust 2. pipe damaged or clogged. Intake Manifold leaking. 3.

Check and reset Ignition Timing. 1. Check condition of exhaust system, 2. repair as needed. Check condition of intake manifold 3. and gasket. Repair as needed. Clean Cylinder Wall Cooling Fins. 4. Check condition of cooling fan. 5. Repair or replace as needed. Replace Piston Rod. 6. Check clearances, replace as 7. needed. Engine speed is self-regulating. Be 8. sure choke if fully open. Reduce electrical load on generator. Check for wear. Replace as needed. 9.

Dirty or clogged Cylinder Cooling Fins. 4. Cooling Fan loose or damaged. 5.

Bent Piston Rod 6. Worn Piston, Piston Ring or Cylinder 7. Wall. Improper engine speed. 8.

Worn Crankshaft Main Bearing. 9.

Mechanical problem

Page 20 of the Chicago Electric 65414 user manual — PLEASE READ THE FOLLOWING CAREFULLY
Page 20 · click to enlarge
Page 20

Equipment Troubleshooting Problem Possible Causes Probable Solutions Engine Will Not Start

Refill the fuel tank. 1. Move the Switch to the ON 2. position. Turn the fuel valve ON. 3. Top off oil level. 4. Check that the spark plug wire is 5. not loose or disconnected. Clean and re-gap spark plug. Replace if necessary. Clean fuel filter cup. Check fuel line 6. for leaks or obstructions. Engine misses, is hard to start or runs poorly

No fuel in tank. 1. Engine Switch in OFF position. 2.

Fuel Valve turned OFF. 3. Engine Oil level low. 4. No spark at spark plug. 5.

No fuel reaching carburetor. 6.

Check and clean the fuel filter. 1. Check and clean the air filter. 2. Check, clean and re-gap spark 3. plug. Power Light does not come on

Fuel filter dirty. 1. Air cleaner dirty. 2. Spark plug dirty or wrong gap. 3.

Improve engine performance. 1. Connect ground wire. 2. Take generator to qualified service 3. technician. No or not enough power at the AC outlets

Engine is running poorly. 1. Ground wire is not connected. 2. Generator is not functioning. 3.

Reset the Breaker Switch to the ON 1. position. Disconnect some appliances to 2. reduce the load. No power at the 12 VDC outlet

AC Breaker switch in the OFF 1. position. AC circuits overloaded. 2.

DC Breaker Switch open. Disconnect the 12 Volt appliance, then press the 12 VDC breaker switch IN. Reconnect the 12 V accessory.

Follow all safety precautions whenever diagnosing or servicing the

equipment or engine. Consult a qualified service technician for any repairs beyond your training or ability.

PLEASE READ THE FOLLOWING CAREFULLY

The manufacturer and/or distributor has provided the parts list and assembly diagram in this manual as a reference tool only. Neither the manufacturer or distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product, or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.

Page 21 of the Chicago Electric 65414 user manual — Main Parts List
Page 21 · click to enlarge
Page 21

Main Parts List

Part Description Qty 1 Gasoline Engine 1 2 Front Cover 1 3 Flange Screw M8X25 16 4 Spring Washer 8 7 5 Washer 8 6 6 Rotor Assembly 1 7 Stator Assembly 1 8 Plain washer 8 5 9 Screw 7/16(24UNC)-210 1 10 Protection board 1 11 Rear cover 1 12 Carbon brush 1 13 5 KW Automatic Voltage Regulator 1 14 Flange Screw M5X16 7 15 Connection pole 1 16 Screw M5 8 17 Spring Washer 5 5 18 Washer 5 8 19 Spring Washer 6 5 20 Toothed Washer 5 2 21 Flange Screw M6X130 4 22 Rear cover 1 23 Flange Screw M5X12 2

Part Description Qty 24 Exhaust Gasket 1 25 Muffler 1 26 Flange Screw M8 18 27 Frame 1 28 Shock Absorber 4 29 Shock Absorber 4 30 Flange Screw M6X12 10 31 Plain washer 6 4 32 Flange Screw M6 10 33 Grounding Wire (10cm) φ6+φ6 1 34 Toothed Washer 6 1 35 Muffler Hood (YAMA) 1 36 Muffler Hood (YAMA) 1 37 Control Panel Assembly 1 38 Flange Bolt M6X16 4 39 Fuel Tank 1 40 Fuel Marker 1 41 Fuel Tank Cap Assembly 1 42 Strainer 1 43 Fuel Tank Cock Assembly 1 44 Fuel Pipe 1 45 Hoop 1 46 Flange Screw M6x45 2

Page 22 of the Chicago Electric 65414 user manual — Diagram
Page 22 · click to enlarge
Page 22

Diagram

Chicago Electric 65414 — Diagram diagram (page 22)
Fig. 7 · Diagram
Page 23 of the Chicago Electric 65414 user manual — Parts List and Diagram A -
Page 23 · click to enlarge
Page 23

Parts List and Diagram A -

Crankcase Assembly

Chicago Electric 65414 — Parts List and Diagram A - diagram (page 23)
Fig. 8 · Parts List and Diagram A -

the Crankcase Cover shown in the above diagram is part # 12a. Whenever refer ring to engine sub-assembly parts, be sure to include the complete part number including the letter suffix.

Chicago Electric 65414 — Parts List and Diagram A - diagram (page 23)
Fig. 9 · Parts List and Diagram A -

Part # Description Qty a 1 Drain Plug 2 a 2 Drain Plug Washer 2 a 3 Crankshaft Oil Seal 2 a 4 Crankcase 1 a 5 Regulating Sway Bar 1 a 6 Washer 1 a 7 Split Pin 1 a 8 Regulating Shaft 1

Part # Description Qty a 9 Snap Ring 1 a 10 Driven Gear Assembly 1 a 11 Dipstick with Seal 2 a 12 Crankcase Cover 1 a 13 Crankcase Gasket 1 a 14 Bearing 6205 2 a 15 Set Pin m 8 x 14 2 a 16 Bolt m8 x 33.5 6

available as separate replacement parts. They may be shown for informational purposes only.

Page 24 of the Chicago Electric 65414 user manual — Parts List and Diagram B -
Page 24 · click to enlarge
Page 24

Parts List and Diagram B -

Cylinder Head Assembly

Chicago Electric 65414 — Parts List and Diagram B - diagram (page 24)
Fig. 10 · Parts List and Diagram B -

Part # Description Qty b 1 Bolt m 6 x 12 6 b 2 Cylinder Head Cover 1 b 3 Cylinder Head Cover Gasket 1 b 4 Valve Rocker Assembly 1 b 5 Push Guide 1 b 6 Cap 1 b 7 Exhaust Spring Seat 1 b 8 Intake Spring Seat 1 b 9 Valve Spring 2 b 10 Bolt m 8 x 60 4 b 11 Stud AM 8 x 34 2 b 12 Cylinder Head Assembly 1

Part # Description Qty b 13 Cylinder Head Gasket 1 b 14 Set Pin 2 b 15 Exhaust Valve 1 b 16 Intake Valve 1 b 17 Tappet 2 b 18 Pusher 2 b 19 Stud AM 6 x 112 2 b 20 Lead Wind Cover 1 b 21 Oil Pipe Seal 1 b 22 Clip 2

Chicago Electric 65414 — Parts List and Diagram B - diagram (page 24)
Fig. 11 · Parts List and Diagram B -
Page 25 of the Chicago Electric 65414 user manual — Assemblies
Page 25 · click to enlarge
Page 25

Parts List and Diagram C - Crankshaft, Piston, Connecting Rod, Camshaft and Flywheel

Assemblies

Chicago Electric 65414 — Assemblies diagram (page 25)
Fig. 12 · Assemblies

Part # Description Qty c 1 Piston Ring Set 1 c 2 Piston Ring Circlip 2 c 3 Piston 1 c 4 Piston Pin 1 c 5 Connecting Rod Assembly 1 c 6 Crankshaft Assembly 1

Part # Description Qty c 7 Camshaft Assembly 1 c 8 Flywheel 1 c 9 Flywheel Fan 1 c 10 Starting Flange 1 c 11 Nut m 14 x 1.5 1

Page 26 of the Chicago Electric 65414 user manual — Parts List and Diagram D - Recoil Starter and Ignition Coil Assembly
Page 26 · click to enlarge
Page 26

Parts List and Diagram D - Recoil Starter and Ignition Coil Assembly

Chicago Electric 65414 — Parts List and Diagram D - Recoil Starter and Ignition Coil Assembly diagram (page 26)
Fig. 13 · Parts List and Diagram D - Recoil Starter and Igniti…

Part # Description Qty d 1 Engine Switch 1 d 2 Fan Hood 2 d 3 Bolt m 6 x 12 5 d 4 Bolt m 6 x 8 4 d 5 Recoil Starter Assembly 1 d 6 Complete Shroud 1

Part # Description Qty d 7 Diode 1 d 8 Oil Sensor 1 d 9 Bolt m 6 x 14 2 d 10 Bolt m 6 x 22 2 d 11 Ignition Coil Assembly 1 d 12 Spark Plug F6TC 1

Page 27 of the Chicago Electric 65414 user manual — Parts List and Diagram F -
Page 27 · click to enlarge
Page 27

Parts List and Diagram E - Air Cleaner and Muffler Assembly

Chicago Electric 65414 — Parts List and Diagram E - Air Cleaner and Muffler Assembly diagram (page 27)
Fig. 14 · Parts List and Diagram E - Air Cleaner and Muffler A…

Part # Description Qty e 1 Air Cleaner Assembly 1 e 2 Nut m6 2 e 3 Air Duct 1

Parts List and Diagram F -

Fuel Supply System

Chicago Electric 65414 — Parts List and Diagram F - diagram (page 27)
Fig. 15 · Parts List and Diagram F -
Chicago Electric 65414 — Parts List and Diagram F - diagram (page 27)
Fig. 16 · Parts List and Diagram F -

Part Description Qty f 1 Pipe Clamp 2 f 2 Fuel Pipe m 4.5 x 170 1 f 3 Intake Gasket 1 f 4 Connecting Block 1 f 5 Carburetor Gasket 1 f 6 Carburetor Assembly 1 f 7 Air Cleaner Gasket 1

Part Description Qty f 8 Regulator Assembly 1 f 9 Back Spring 1 f 10 Regulating Spring 1 f 11 Pulling Rod 1 f 12 Lock Bolt 1 f 13 Regulating Spring 1 f 14 Nut M6 1

Page 28 of the Chicago Electric 65414 user manual — Record Product’s Serial Number Here:
Page 28 · click to enlarge
Page 28

Parts List and Diagram G - Starter and Generator Assembly

Chicago Electric 65414 — Parts List and Diagram G - Starter and Generator Assembly diagram (page 28)
Fig. 17 · Parts List and Diagram G - Starter and Generator Ass…

Part # Description Qty g 1 Starting Motor Assembly 1 g 2 Bolt m6 x 28 1 g 3 Bolt m6 x 32 1 g 4 Crankcase 1 g 5 Charge Coil 1

Part # Description Qty g 6 Bolt m6 x 35 2 g 7 Clamp Cord 1 g 8 Bolt m6 x 12 2 g 9 Flywheel 1

Record Product’s Serial Number Here:

able individually as replacement parts.

Page 29 of the Chicago Electric 65414 user manual — Wiring Diagram
Page 29 · click to enlarge
Page 29

Wiring Diagram

Chicago Electric 65414 — Wiring Diagram diagram (page 29)
Fig. 18 · Wiring Diagram
Page 30 of the Chicago Electric 65414 user manual — Emission Control System Warranty
Page 30 · click to enlarge
Page 30

quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

Limited 1 year / 90 Day

warranty

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor, the belts (if so equipped), and the blades (if so equipped) are free of defects in materials and workmanship. Harbor Freight Tools also warrants to the original purchaser, for a period of one year from date of purchase, that all other parts and components of the product are free from defects in materials and workmanship (90 days if used by a professional contractor or if used as rental equipment). This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. This warranty is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

  • 3491 Mission Oaks Blvd.
  • PO Box 6009
  • Camarillo, CA 93011
  • (800) 444-3353

Emission Control System Warranty

United States Emission Control Defects

The United States Environmental Protection Agency (herein EPA) and Harbor Freight Tools (herein HFT) are pleased to explain the emission control system warranty on your 1997 and later Small Off-Road Engine (herein engine). Within the United States, new off-road, spark-ignition engines certified for model year 1997 and later, must be designed, built and equipped to meet the stringent anti-smog standards set forth by the EPA. HFT must warrant the emission control system on your engine for the periods of time described below, provided there has been no abuse, neglect or improper maintenance of your engine.

Your emission control system may include parts such as the carburetor or fuel-injection system, and the ignition system. Also included may be hoses, belts, connectors and other emission- related assemblies.

Where a warrantable condition exists, HFT will repair your engine at no cost to you including diagnosis, parts and labor.

The 1997 and later engines are warranted for two (2) years. If any emission-related part on your engine is defective, the part will be repaired or replaced by HFT.

Harbor Freight Tools Emission Control Defects

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and

Engines are warranted for a period of two (2) years relative to emission control parts defects, subject to the provisions set forth below. If any emission related part on your engine is defective, the part will be repaired or replaced by HFT.

Owner’s Warranty Responsibilities As the engine owner, you are responsible for the performance • of the required maintenance listed in your Owner’s Manual. HFT recommends that you retain all receipts covering maintenance on your engine, but HFT cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.

Warranty Statement · Manufacturer’s Warranty Coverage · Warranty Coverage

Page 31 of the Chicago Electric 65414 user manual — CONTROLS
Page 31 · click to enlarge
Page 31
  • As the engine owner, you should, however, be aware that
  • HFT may deny you warranty coverage if your engine or a part has failed due to abuse, neglect, improper maintenance, or unapproved modifications. You are responsible for shipping your engine to a HFT
  • warranty station as soon as a problem exists. Contact the HFT Customer Service department at the number below to make shipping arrangements. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.

replacement point for that part. Any replacement part, provided it is equivalent in durability and performance, may be used in performance of maintenance or repairs. The owner is responsible for commissioning a qualified technician/ mechanic to perform all required maintenance, as outlined in the Inspection, Cleaning, and Maintenance section in this manual.

Warranted Parts 6. Fuel Metering System 1) Carburetor and its internal parts. i)

If you have any questions regarding your warranty rights and responsibilities, you should contact the Harbor Freight Tools Customer Service Department at 1-800-444-3353.

Fuel pump (if so equipped). ii)

Cold start enrichment system. iii) Air Induction System 2) Intake pipe/manifold. i)

Harbor Freight Tools Emission Control Defects

Air cleaner. ii) Ignition System 3) Spark plug. i)

Length of Coverage 1. HFT warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of warranted parts for a period of two (2) years after the date of delivery to the first retail purchaser.

Magneto ignition system. ii) Catalyst System (if so equipped) 4) Exhaust pipe stud. i)

Muffler. ii)

No Charge Repair or Replacement 2. Repair or replacement of any warranted part will be performed at no charge to the owner if the work is performed through a warranty station authorized by HFT. For emissions warranty service, contact the HFT Customer Service Department at 1-800-444-3353.

Catalytic converter (if so equipped). iii) Miscellaneous Items Used in Above Systems 5) Vacuum, temperature and time sensitive valves i)

and switches. Hoses, belts, connectors, and assemblies. ii)

Consequential Damages Coverage 3. Coverage under this warranty shall also extend to the failure of any engine components caused by the failure of any warranted part while it is still covered under this warranty.

Coverage Exclusions 4. Warranty claims shall be filed in accordance with the provisions of the HFT warranty policy explained in the box at the top of the previous page. HFT shall not be liable for any loss of use of the engine, for any alternative usage, for any damage to goods, loss of time, or inconvenience. Warranty coverage shall also be excluded for any part which fails, malfunctions, or is damaged due to failure to follow the maintenance and operating instructions set forth in the Owner’s Manual including, but not limited to:

Use of parts which are not authorized by HFT a)

Improper installation, adjustment or repair of the engine b)

or of any warranted part unless performed by an authorized warranty center Failure to follow recommendations on fuel use contained c)

in the Owner’s Manual Improper or inadequate maintenance of any warranted d)

parts Repairs performed outside of the authorized warranty e)

service dealers Alterations by changing, adding to or removing parts f)

from the engine.

Service and Maintenance 5. Component parts which are not scheduled for replacement as required maintenance or are scheduled only for regular inspection to the effect of “repair or replace as necessary” are warranted for the warranty period. Any warranted part which is scheduled for replacement as required maintenance is warranted for the period of time up to the first scheduled

Warranty Provisions

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Engine is PingingExcess wear of: • Piston, Cylinder Wall or Rings. • Piston Pin or Piston Pin Hole. • Connecting Rod Wrist Pin. • Crankshaft Roller Bearing.Check wear, replace as needed. p.18
Abnormal Com­ bustion or engine running hot or excess smoking.1. Combustion chamber carbon fouling. 2. Dirty or old gasoline or oil in gas.1. Clean out Combustion chamber and spark plug. 2. Drain gas, clean out fuel filter and replace with fresh gas, minimum 91 octane premium unleaded gasoline. p.18
Engine does not start.1. Engine Switch in OFF position. 2. Water in Carburetor Bowl. 3. Spark Plug gap not correct. 4. Incorrect Ignition Timing. 5. Damaged coil or ignition wires. 6. Low Oil level.1. Move Switch to ON position. 2. Drain carburetor Bowl, clean Fuel Filter. 3. Clean and re-gap plug at 0.030”. Replace plug if needed. 4. Check timing and adjust. 5. Check for damaged wires, test output. 6. Check oil level, top off as needed. p.18
Engine runs excessively hot1. Improper Ignition Timing. 2. Exhaust manifold, muffler or exhaust pipe damaged or clogged. 3. Intake Manifold leaking. 4. Dirty or clogged Cylinder Cooling Fins. 5. Cooling Fan loose or damaged. 6. Bent Piston Rod 7. Worn Piston, Piston Ring or Cylinder Wall. 8. Improper engine speed. 9. Worn Crankshaft Main Bearing.1. Check and reset Ignition Timing. 2. Check condition of exhaust system, repair as needed. 3. Check condition of intake manifold and gasket. Repair as needed. 4. Clean Cylinder Wall Cooling Fins. 5. Check condition of cooling fan. Repair or replace as needed. 6. Replace Piston Rod. 7. Check clearances, replace as needed. 8. Engine speed is self-regulating. Be sure choke if fully open. Reduce electrical load on generator. 9. Check for wear. Replace as needed. p.19

Ask about the Chicago Electric 65414

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Chicago Electric 65414

Be the first to ask — other owners or our team will answer.

Original document

Chicago Electric 65414 manual PDF

31 pages·1.9 MB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…