CONTROLLER BOARD GL Serial # ________________________ (located on electrical box cover) Installation Date __________________ 2 YEAR W ARRANTY MODEL HS670 IS FOR VEHICULAR P ASSAGE GA TES ONL Y AND ARE.
2 CARTON INVENTORY Before beginning your installation check that all components were supplied and received undamaged. Refer to list below for factory supplied parts.
3 G. LIMIT SWITCH All limit switches are oil tight and watertight, and of NEMA 3, 4, and 13 construction. Open switch for right hand, close switch for left hand. H. DRIVE WHEELS Drive wheels are constructed of polyurethane material on a steel hub and have a hardness factor of 95.
4 OPERA TOR SPECIFICA TIONS MODEL HS670 GC • 1 HP Motor Gate Speed – 12"/sec. Maximum Gate Weight – 3000 lbs. Maximum V-T rack Gate Width – 80 ft. MODEL HS670 GI • 1 HP Motor Gate Speed – 18"/sec. Maximum Gate Weight – 3000 lbs.
5 CLASS I – RESIDENTIAL VEHICULAR GA TE OPERA TOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
6 SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security . Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
7 Close Edge Open Edge Run Twisted Wire From Loop To Detector Seal Loops 4' 4' Typical 4' Typical Interrupt Loop Photo Eye For Close Cycle 4' Typical STREET 8' Sentex Telephon.
8 NOT FOR USE AS PEDESTRIAN P ASSAGE! This operator is intended for vehicular use only . T o prevent INJURY to pedestrians, a separate pedestrian access should be supplied, visible from the gate. Locate the pedestrian access where there is not a chance of INJURY at any point during full movement of the gate.
9 “Gate” Shown Open As Required 2.75 5.88 Anchor Location Marked "Z" Z Z Optional Emergency Disconnect Power Conduit Entrance 4.13 35.00 3.88 1.75 1.75 1.75 3.00 3.75 1.75 Z Z + = Critical Dimension 14.00 26.50 +7.50 NOTES: Installation shown is for a right-handed unit (on right side of gate opening when inside looking out).
10 INST ALL A TION Remove Bolt to T ake Cover Off Loosen Screw to Remove Cover V ent Cap IMPORT ANT : Do Not Use Cover Handles to Move Unit Ta n k Threaded Plug VENT CAP 1. Remove the threaded plug from the pump tank. 2. Install the vent cap. NOTE: Never run the operator without the vent cap installed.
11 INST ALL A TION GATE STOPS 1. When properly installed the gate will open or close in approximately 3" to 4" after limit shoe shuts the unit off, the “gate stop” will contact the upper drive wheel stopping the gate.
12 POWER WIRING INSTALLATION Wiring Specifications (STRANDED COPPER WIRE) On a Dual Gate System, each unit must be installed on ITS OWN separate circuits. NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation.
13 IMPORT ANT NOTE: On three phase operators, power connections must be properly phased. If phased incorrectly , the gate operator will run reversed. T o correct this situation, shut off power at main power source and at the operators electrical disconnect switch.
14 ADJUSTMENT T o reduce the risk of SEVERE INJURY or DEA TH: • Disconnect power BEFORE performing ANY adjustments. WARN ING CAUTION WARN ING WARN ING HALL EFFECT SENSOR ADJUSTMENT NOTE: Normally the hall effect sensor does not need adjustment, but may go out of alignment due to shipping vibration or rough handling.
15 UL325 ENTRAPMENT PROTECTION PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Force Control Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force.
16 Motor Learn Button (S3) Relay Drive T roubleshooting LEDs (D6) T erminal Troubleshooting LEDs (D1 1) Limit LEDs Dip Switch (S1) Diagnostic LED Dip Switch (S2) Force Adjustment T imer to Close Dip S.
17 SLIDE/SWING This switch (S1-2) selects slide or swing gate operation, in order to optimize gate behavior for specific application. SL = Slide, 1 second delay SW = Swing, 1.5 second delay RIGHT/LEFT OPERA TION This switch (S1-3) selects the gate opening direction, to the left or to the right.
18 Street 6' (Gate Conduit) Complex or Parking Lot Int errupt Lo op Int errupt Loop HS670 HS670 PROGRAM SETTINGS (DIP SWITCH #2) CONT’D EDGE/PHOTO OPEN This switch (S2-3) selects edge or photo sensor for the gate opening protection input.
19 PROGRAMMING THE RADIO RECEIVER SET SECURITY MODE The Universal Receiver can be used with up to 15 rolling code transmitters or passwords in HIGH security mode. Alternately , it can be used with up to 31 of any type transmitter in NORMAL security mode, including any combination of rolling code, billion code, or dip switch remotes.
BG770 T raffic Hold Open Loop Street SAMS Conduit Interrupt Loop Complex or Parking Lot BG770 HS670 HS670 20 1 (OPEN) 3 (COMMON) Auxiliary Limit Switch N/O COM Interrupt Loop Input TB8 TB5 SAMS Relay .
21 ACCESSORY WIRING STOP/RESET AUXILIARY CONTROL WIRING T erminals 6 & 5 (Com) - Open These terminals are intended for use as a general open control. Accessories that may be wired to this input include: T elephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector , Keypads, 7-Day Timer .
22 CONTROL CONNECTION DIAGRAMS J1 TERMINAL BLOCK 3 89 10 11 12 1 3 14 24 V AC R1 R3 R2 R4 12 4 67 5 3 89 10 11 12 1 3 14 12 4 67 5 16 17 15 18 19 20 21 22 23 24 25 26 27 28 Hard Close Control Input (N.O.) Soft Open Input (N.O.) Hard Open Control Input (N.
Hall Effect (RPM) Sensor Check for wear , oil damage and X proper operation External Entrapment Check for proper operation X Protection Systems Gate Caution Signs Make sure they are present X Manual D.
24 GL BOARD FEATURES DIAGNOSTICS (LEDS AND CODES) There are three diagnostic LEDs. T wo red LEDs (OL, CL) are indicators for the open and close limits. The LEDs are illuminated when the limit switch contacts are closed. The third amber LED (DIA) is used to blink out diagnostic codes.
25 OPERA TOR FAILS TO RUN CONT ACTOR CHA TTERS WHEN OPERA TOR BEGINS TO MOVE OPERA TOR RUNS SLOW AND/OR TRIPS THE INTERNAL OVERLOAD 1) No stop control 2) Fault in the operator check the yellow diagnostic LED at the top right of the GL board next to the programming dip switches.
26 F AUL T POSSIBLE CAUSE FIX MASTER OR SECOND OPERA TOR IS NOT FUNCTIONING PROPERL Y OPERA TOR RUNS BUT THEN STOPS AND REVERSES DIRECTION MOTOR RUNS BUT GA TE DOES NOT MOVE; OPERA TOR STOPS AND ALARM.
27 (A) BYP ASS V AL VE: It MUST be in the “automatic” position (horizontal). If it is in the manual position, no fluid gets to the drive motors, so they won’t turn. If the bypass lever is between positions, fluid will be bled off, so motors will turn slower .
28 HYDRAULIC MOTORS 1. The two hydraulic motors are “ROLLER V ANE” type and are machined to be free wheeling. Each motor has a displacement of 12 in 3 /rev . 2. The speed of each is approximately 55 RPM which equates to a gate speed of approximately 18"/ sec.
Directional Valve Wiring Assembly Relief Valve Built-In Directional Valve Port “A” Port “B” Directional Valve Override (DV-1) Directional Valve Override (DV-2) Bypass Valve Handle From Drive Motor Vent Cap (add fluid here) 29 HYDRAULIC DON’TS 1.
30 SINGLE PHASE WIRING DIAGRAM (LEFT) (RIGHT) OVERLOAD (SEE NOTE 6) BALDOR MOTOR CONNECTIONS EMMERSON MOTOR CONNECTIONS NOTES: 1. T ransformer primar y voltage same as operator line voltage 24V secondary 60V A. 2. Wire color: 120V black, 230V orange. 3.
31 THREE PHASE WIRING DIAGRAM (LEFT) (RIGHT) 4 NOTES: 1. T ransformer primar y voltage same as operator line voltage 24V secondary 60V A. 2. Wire color: 230V orange, 460V violet. 3. Coil voltage same as line voltage. 4. (B+) and (B-) are 100db safety alarms.
32 ELECTRICAL BOX 2 13 9 12 9 4 1 11 8 10 7 3 5 6 14 15 ITEM P ART # DESCRIPTION QTY NOTES PROVIDED IN KIT 1 K001A5566 Control Board 1 Individual Part 2 03-8024-K Contactor , 3 Pole Reversing 1 Indivi.
33 ILLUSTRA TED P ARTS 13 1 2 3 4 5 6 7 8 9 10 10 11 15 12 14 16 17 3 3 ITEM P ART # DESCRIPTION QTY NOTES PROVIDED IN KIT 1 K20-1100 Motor , 1HP 115/230V 1PH 1 1HP 1PH Units Individual Part K20-3100C-4 Motor , 1HP 230/460V 3PH 1HP 3PH Units K20-3200C-4 Motor , 2HP 230/460V 3PH 2HP 3PH Units 2 K32-19007 Hydraulic Pump, Class 3&4 1 18 I.
LIFTMASTER ® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase.
35 OPERA TOR NOTES.
REP AIR P ARTS AND SERVICE ©2006, The Chamberlain Group, Inc. 01-18826F All Rights Reserved HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZA TION SP ANS AMERICA For installation and service information, call our TOLL FREE number: 1-800-528-2806 www .
An important point after buying a device Chamberlain HS670 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chamberlain HS670 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chamberlain HS670 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chamberlain HS670 you will learn all the available features of the product, as well as information on its operation. The information that you get Chamberlain HS670 will certainly help you make a decision on the purchase.
If you already are a holder of Chamberlain HS670, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chamberlain HS670.
However, one of the most important roles played by the user manual is to help in solving problems with Chamberlain HS670. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chamberlain HS670 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center