Instruction/ maintenance manual of the product EL MODELS Chamberlain
Go to page of 32
T elephone entr y/access control sy s tem © 2008 The Chamberlain Group, Inc. All Rights Reser ved ® ™ ® ™ Ins t allation Manual for Ins t allation Manual for EL MODELS EL MODELS.
.
Table of Contents Page 1 Mounting the Unit Page Dimensions 2 EL25 Installation 3 Rotating the Keypad for Vertical Mounting 3 Unlocking/Locking EL2000 4 EL2000 Installation 5 Wire Type Wire Connections.
Page 2 Dimensions Dimensions Caution! A Static Discharge can Damage Circuit Boards 6 in. 3-15/16 in. Mounting Holes (4) for 5/16 in. 3/4 in. Conduit Hole 1-1/4 in. Conduit Hole Knockouts for 5/16 in. Knockouts for 3/8 in. 15 in. AUG 10, 2005 WELCOME 3-1/16 in.
Page 3 EL25 Installation EL25 Installation DO NOT overload the removable terminal block connectors. One wire per hole. DO NOT pinch wires when closing and locking the unit.
Page 4 Unlocking/Locking EL2000 Unlocking EL2000 1. Apply pressure to the right-side of the unit. 2. While maintaining pressure, turn key clockwise 3. Open cover Locking EL2000 1. Turn key counter clockwise to lock position 2. Close cover 3. Apply pressure to left-side until you hear a “click” sound 4.
Page 5 # 1 2 3 ? 4 5 6 7 8 9 * 0 # # # # # # 1 2 3 4 5 6 7 8 9 0 * # ? # # # # # EL2000 Model Installation EL2000 Installation 1 Unlock Unit 2 Open Cover 3 Unplug the 2 Main Harnesses (Optional) 4 Sli.
Page 6 Wire Connections to the Unit Input Board Connections 1. Door 1 Exit Request and Door Status 2. Door 2 Exit Request and Door Status 3. Door 3 Exit Request and Door Status 4. Door 4 Exit Request and Door Status 5. Postal Lock Input 6. AutoCall Input 7.
Page 7 Wire Specs and Run Distances Wire Specs and Run Distances Use this chart to pull wires in preparation of your installation: Power Wire Specs and Run Distances Description of Wire Run Grounding .
Page 8 Grounding the Units Grounding the Units Ensure that the system is grounded properly. The units contain a number of static sensitive components that can be damaged by static discharge. IMPORTANT: An Earth Ground Rod is Strongly Recommended and should be no further than 12 feet from the unit and use a minimum of 12 gauge wire in most cases.
Page 9 Wiring 1 Unit to Telco Line Wiring 1 Unit to Telco Line The bypass board allows the unit to be disconnected without interrupting normal telephone operation. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 10 Wiring Multiple Units to Telco Line Wiring Multiple Units to Telco Line Up to 7 units can share the same phone line. The bypass boards allow the units to be disconnected without interrupting normal telephone operation.
Page 11 Wiring with No Telco Line Wiring with No Telco Line The unit can be a stand alone system that allows communication between the unit and a resident’s phones. Single Unit Tip Ring Tip Ring RES TELCO Use 18-24 AWG 2 twisted pair Output Board (See page 6) NOTE: Ringer Equivalence Number (REN) of “5” maximum.
Page 12 Wiring to Dedicated Telco Line Wiring to Dedicated Telco Line IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J.
Page 13 Wiring to an Internal Phone System Wiring to an Internal Phone System The units can be wired to any Analog Trunk in an internal home phone system. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 14 Connection To A NPBI System Connection To An NPBI System IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Tip.
Page 15 Wiring a Door Strike Lock/Maglock Wiring a Door Strike Lock Wiring a Maglock IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Use 18-22 AWG NOTE: The door strike can be connected to any of the 4 relays.
Page 16 Wiring a Gate Operator / Key Switch / PIR / REX Wiring a Gate Operator Wiring a Key Switch/PIR/REX Any auxiliary opening device such as a key switch or PIR (Passive Infrared Device), or an exit request button (REX) that provides normally open contact closure can be hooked up to the Door Input terminals.
Page 17 Wiring a Door Sensing Device / AutoCall Wiring a Door Sensing Device The units can monitor the position of up to four doors/gates and may react to a change in their status with one of the relays (not set as a control relay).
Page 18 Wiring a RF Module / Card Reader / Keypad Wiring a Radio Frequency Module An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information.
Page 19 Wiring a Postal Lock Switch / Internal Camera (CCTV) Wiring a Postal Lock Switch - EL25 Models Only The Post Office requires installation of a postal lock if postal carriers do not have access to a controlled area. Contact the local post office and arrange for them to install the postal lock while you are on site.
Page 20 Wiring Power to the Unit Wiring Power to the Unit The 110 VAC outlet must be dedicated to the unit ONLY . This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems: • Other equipment cannot introduce spikes, noise, surges or dips into the power circuit.
Page 21 J500 H2 100A UD H2 100A UD 3D2 100 16B J406 LCD J201 MIC J403 D2 D102 D153 3D2 100 16B 3D2 100 16B 3D2 100 16B H2 100A UD 3D2 100 16B J400 + DEVICE 1,2 Description Type Used on Model 1 11 10 9 8 7 6 5 4 3 2 No.
Page 22 Troubleshooting Troubleshooting Wiring • Check for correct length and AWG of wires. See page 7. • Check that wires are correctly inserted into the terminal blocks (not loose, no two sharing the same position). • Check board markings for correct terminal block placements.
Page 23 Repair Parts Repair Parts Installation and Service Information is Available Call our Toll Free Number 1-800-528-2806 www.chamberlain.com 17 21 22 18 19 20 16 15 10 13 14 11 11 12 8 9 7 4 5 6 1.
Page 24 EL2000 Parts Repair Parts Repair Parts 8 1 2 3 4 6 7 5 16 17 20 9 19 13 12 21 18 22 14 10 15 23 When ordering repair parts, please supply the following information: Description and Model Numbe.
Page 25 Your System Diagram Your System Diagram.
Page 26 Your Wiring Configuration Your Wiring Configuration External Access Control Device(s) connected to optional board(s) Device 0 __________________________________________________________________.
Page 27 Accessories Accessories 0 0 4 J 0 0 2 J 2 0 4 J 6 0 4 J 1 0 2 J 7 0 4 J 4 0 4J 1 0 4 J 6 0 4 J 4 0 4J 1 0 4 0 0 4 J N O C I T I N U W E N e h t k c i l C . 1 t i n U r e t n E d n a e m a N e p y T t i n U 1 , y r t n u o C r e t n E y t i C d n a .
Page 28 FCC and DOC Requirements FCC and DOC Requirements FCC Requirements The units comply with Part 68 of the FCC Rules. The label affixed to this equipment contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment.
.
845 L arch Avenue Elmhurs t, Illinois 60125-1196 114A2980 F ® ™ © 200 8 The Chamberlain Group, Inc. All Rights Reser ved.
An important point after buying a device Chamberlain EL MODELS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chamberlain EL MODELS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chamberlain EL MODELS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chamberlain EL MODELS you will learn all the available features of the product, as well as information on its operation. The information that you get Chamberlain EL MODELS will certainly help you make a decision on the purchase.
If you already are a holder of Chamberlain EL MODELS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chamberlain EL MODELS.
However, one of the most important roles played by the user manual is to help in solving problems with Chamberlain EL MODELS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chamberlain EL MODELS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center