Vent-Free Gas Room Heatersp.1Models: UVC36 / UVS36 UVC43 / UVS43p.1— Do not store or use gasolinep.1— What to Do If You Smell Gasp.1Homeowner's Installation andp.1— Installation and service mustp.1Operating Manualp.1Installation & Operating Instructionsp.3Safety Devicesp.5F G H Ip.5Descriptionp.5Clearance to Combustiblesp.5CFM170p.5Mantelsp.6Framingp.6Planningp.6Insulating for Cold Climatesp.6Mounting the Heaterp.6High Elevationsp.7Gas Supply Pressuresp.7Connect the Gas Linep.7EB1 (Receptacle) Hook-Upp.8Electrical Connectionp.8Slide the Heater in Placep.9Level and Secure the Heaterp.9Finishingp.9Alternate Switch Locationp.9Operating Instructionsp.10Glass Informationp.10DV34-2p.10Louvre Removalp.10Log Installationp.10Window Frame Assembly Removalp.10Glass Cleaningp.10Flame Characteristicsp.11Ember Material Placementp.11Lava Rockp.11First Firingp.11Flame Adjustmentp.11Lighting And Operating Instructionsp.12FOR YOUR SAFETY READ BEFORE LIGHTINGp.12WARNING:If you do not follow these instructions exactly, a fire or explosionp.12Lighting Instructionsp.12PILOTp.12OFFp.12F Pp.12ONp.12To Turn Off Gas To Heaterp.12Troubleshootingp.13Nova SIT 820p.13STARTp.13CHECKp.13YESp.13NOp.13FP396Ap.13Maintenancep.14Cleaning Catalytic Filtersp.14Cleaning the Standing Pilotp.14(UVC Only)p.14Control Systemp.14Optional Accessoriesp.17Fan Kitp.17Remote Controlsp.17Ceramic Refractory Panelsp.17Arched Door Frontp.17Hard (Direct) Wire Hook-Upp.17Decorative Frame Trimsp.18Decorative Bay Windowp.18EB-1 Electrical Boxp.18Outside Air Terminationp.18BASIC WARRANTYp.19EXTENDED LIFETIME WARRANTYp.19COMPONENT WARRANTYp.19CONDITIONS AND LIMITATIONSp.19IF WARRANTY SERVICE IS NEEDED…p.19CFM Specialty Home Productsp.20
Page 1 of the CFM UVS36 user manual — E
Page 1 · click to enlarge
Page 1

PLEASE READ THIS MANUAL BEFORE INSTALLING AND US- ING APPLIANCE.

™

Vent-Free Gas Room Heaters

Models: UVC36 / UVS36 UVC43 / UVS43

— Do not store or use gasoline

or other flammable vapors and liquids in the vicinity of this or any other appliance.

— What to Do If You Smell Gas

  • Do not try to light any appliance.
  • Do not touch any electrcal switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
  • If you cannot reach your gas supplier, call the fire department.

Homeowner's Installation and

— Installation and service must

Operating Manual

be performed by a qualified installer, service agency or the gas supplier.

S

D

E

G

N

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combus- tion and ventilation air must be provided. Refer to Page 4.

E

D

R

T

F

E

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

20000135 9/05 Rev. 4

Page 2 of the CFM UVS36 user manual — Vent-Free Gas Room Heaters
Page 2 · click to enlarge
Page 2
Page 2 of the CFM UVS36 user manual — Vent-Free Gas Room Heaters
Page 3 of the CFM UVS36 user manual — Installation & Operating Instructions
Page 3 · click to enlarge
Page 3

Installation & Operating Instructions

This gas room heater should be installed by a qualified installer in accordance with local building codes and with current Na- tional Fuel Gas Code. ANSI Z223.1/NFPA 54. "This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air". "The National Fuel Gas Code, ANSI Z233.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the ag- gregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space.. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space of if the build- ing is of unusually tight construction, provide adequate combus- tion and ventilation air by one of the methods, described in the National Fuel Gas Code, ANSI Z 223.1/NFPA 54, Section 5.3 or applicable local codes." Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed, and b) Weather stripping has been added on openable windows and doors, and c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

FOR SAFE INSTALLATION AND OPERATION OF YOUR VER- MONT CASTINGS MAJESTIC PRODUCTS COMPANY VENT- FREE ROOM HEATER PLEASE NOTE THE FOLLOWING: 1. This heater gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of the high temperatures surface of this heater and should stay away to avoid burns or ignition of clothing. 3. Young children should be carefully supervised when they are in the same room as your heater. 4. Under no circumstances should this heater be modified. Parts removed for service should be replaced prior to oper- ating this heater again. 5. Installation repair to this heater should be done by a quali- fied service person. A professional service person should be contacted to inspect this heater annually. Make it a practice to have all of your gas heaters checked annually. More fre- quent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this heater should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit. 7. Under no circumstances should any solid fuels (wood, coal, paper or cardboard, etc.) be used in this heater. 8. Keep the area around your heater clear of combustible ma- terials, gasoline and other flammable vapor and liquids. This heater should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung in the area of it. 9. Whether the heater is installed directly on carpeting, vinyl tile or any combustible material other than wood, this heater must be installed on a metal or wood panel extending the full width and depth of the heater. 10. Do not install heater in bedroom or bathroom. 11. Do not place clothing or other flammable material on or near the appliance. 12. Any safety screen or guard removed for servicing an appli- ance must be replaced prior to operating the heater. 13. Do not use this room heater if any part has been under water.

Fireplace screen (when equipped) must be closed while the appliance is in operation. WARNING: Do not allow LP tank below 1/4 full. WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame pat- terns. WARNING: Do not use a blower insert, heat exchanger or other accessory not approved for use with this heater. WARNING: Any change to this heater or its controls can be dangerous.

This appliance is intended for supplemental heating.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile home), where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

20000135

Page 4 of the CFM UVS36 user manual — Installation & Operating Instructions
Page 4 · click to enlarge
Page 4
CFM UVS36 — Installation & Operating Instructions diagram (page 4)
Fig. 1 · Installation & Operating Instructions

Rough Opening Width 36¹⁄₂" Finished Wall Thickness

5³⁄₄" 3¹⁄₄" 7³⁄₄" 2"

Fig. 1 UVC/UVS36 specifications and framing.

CFM UVS36 — Installation & Operating Instructions diagram (page 4)
Fig. 2 · Installation & Operating Instructions

Rough Opening Width 43¹⁄₂" Finished Wall Thickness

Fig. 2 UVC/UVS43 specifications and framing.

20000135

Page 5 of the CFM UVS36 user manual — CFM170
Page 5 · click to enlarge
Page 5
V W X Y Z A B C D E Fireplace Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim CFM146 Ref.Mantel Shelf DepthRef. Mantel From Top of Comb. Chamber V10" (254 mm)A19" (483mm) W8" (203 mm)B17" (432mm) X6" (152 mm)C15" (381mm) Y4" (101 mm)D13" (330mm) Z2" ( 51 mm)E11" (279mm)
CFM UVS36 — Safety Devices diagram (page 5)
Fig. 3 · Safety Devices

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your Vermont Castings Majestic Products fireplace for a least six (6) hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.

Safety Devices

Adequate combustion and ventilation air must be pro- vided. The flow of combustion and ventilation air MUST NOT be obstructed.

Provide adequate clearances around the air opening into the combustion chamber; and adequate accessibili- ty clearance for servicing and proper operation. NEVER obstruct the front opening of the heater or cover the top and bottom louvres (grilles).

Fig. 3a Combustible mantel minimum installation.

These heaters are equipped with a pilot system fea- turing an Oxygen Depletion Sensor (O.D.S.) shut-off device. All unvented heaters are required to have this system. The O.D.S. pilot will shut down the heater when there is not enough fresh air available.

J

F G H I

Report any parts damaged in shipment to your dealer.

Description

K Side of Combustion Chamber

The UVC vent-free heaters are unique in featuring two catalytic filters and a frame window with glass that actually clean room air as well as give excellent zone heating.

M

N

O

The UVS vent-free heaters use a frame window with screen mesh that does not use any catalytic filters.

Each model is available as Natural or Propane gas, equipped with a standing pilot.

Design-certified to ANSI Z21.11.2a-2003. Gas-Fired Room Heaters — Vol. II, Unvented Room Heaters.

Clearance to Combustibles

Top of unit to ceiling 36" (914 mm) Front of unit to combustibles 36 (914 mm) Appliance Top 0" (0 mm) Bottom 0" (0 mm) Sides 0" (0 mm) Back 0" (0 mm) Perpendicular sidewall 6" (152 mm)

CFM170

Mantel Mantel Leg From Side Ref. Leg Depth Ref. of Comb. Opening F 10" (254 mm) K 11¹⁄₂" (292 mm) G 8" (203 mm) L 9¹⁄₂" (241 mm) H 6" (152 mm) M 7¹⁄₂" (191 mm) I 4" (101 mm) N 5¹⁄₂" (101 mm) J 2" ( 51 mm) O 3¹⁄₂" (89 mm)

Fig. 3b Combustible mantel leg minimum installation.

Mantel Leg · CFM164a · 20000135

Page 6 of the CFM UVS36 user manual — Mounting the Heater
Page 6 · click to enlarge
Page 6
CFM UVS36 — Mantels diagram (page 6)
Fig. 4 · Mantels

Mantels

Depending on the width of the mantel it may be in- stalled higher or lower from the combustion chamber opening. This also applies to the distance between the mantel leg (if installed) and the fireplace. Refer to Fig- ures 3a and 3b for correct mounting heights and widths for combustible mantels and mantel legs.

Scew Drywall Position Depths A 1/2" (13 mm) B 5/8" (16 mm) C 3/4" (19 mm)

Noncombustible mantels and legs may be installed at any height above the appliance opening.

CFM UVS36 — Mantels diagram (page 6)
Fig. 5 · Mantels

When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discoloration.

Fig. 4 Adjustable drywall strip (nailing flange).

Framing

A hearth extension in front of heater is recommended but not required.

Framing can take place before or after the heater is set in place. The framing should be positioned to accom- modate the wall covering and facing material. Framing material should be 2x4 or heavier. Framing headers may rest on top of heater. (Refer to Page 4, Figures 1 and 2 for heater and framing dimensions.)

Planning

Planning the installation is an important first step: it will save time and money later in the actual installation. In planning the installation, consider:

1. Where the heater will be located. 2. All components needed to complete the project.

Insulating for Cold Climates

When a heater is installed in a chase or an outside wall, the enclosure should be insulated like any other wall of the home. Insulation should be installed under the heater and on the inside of the exterior walls. (Fig. 5)

Mounting the Heater

The heater should only be mounted on the following surfaces:

  • A flat combustible (burnable) surface.
  • A raised wooden platform.
  • A concrete block or other solid object placed beneath each of the four corners of the heater.
CFM UVS36 — Mounting the Heater diagram (page 6)
Fig. 6 · Mounting the Heater

To mount the heater:

Insulation methods shown are optional for cold climate, not a require- ment for unit operation.

1. Choose unit location. 2. Place unit in position and secure to floor with 1¹⁄₂" screws, or nails. The holes to secure the unit to the floor are located just behind the bottom louvre on the left and right hand side of the unit. 3. Frame in heater with a header across the top. It is important to allow for finished face when setting the depth of the frame. 4. Attach heater to frame using adjustable frame drywall strips (located behind access door for shipping). Preset depth to suit facing material (adjustable to 1/2" , 5/8" or 3/4" depths). (Fig. 4) 5. Use existing screws in side of unit to attach drywall strip. Measure from face of heater to face of drywall strip to determine final depth. (Fig. 4)

Fig. 5 Insulating for cold climates.

20000135

Page 7 of the CFM UVS36 user manual — Connect the Gas Line
Page 7 · click to enlarge
Page 7
CFM UVS36 — High Elevations diagram (page 7)
Fig. 7 · High Elevations

High Elevations

Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.

Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)

For elevations above 4,500 feet (1,370m), instal- lations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

The installation of your Majestic Fireplaces room- heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition. (EX- CEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas.)

Fig. 6 Parts identification.

CFM UVS36 — High Elevations diagram (page 7)
Fig. 8 · High Elevations
Gas Specifications ModelFuel Gas ControlMax. Input B.T.U.H.Min. Input B.T.U.H. UVC36RNNatural Millivolt Hi/Lo25,00017,500 UVC36RPPropane Millivolt Hi/Lo25,00018,750 UVS36RNNatural Millivolt Hi/Lo25,00017,500 UVS36RPPropane Millivolt Hi/Lo25,00018,750 UVC43RNNatural Millivolt Hi/Lo33,00023,100 UVC43RPPropane Millivolt Hi/Lo33,00024,750 UVS43RNNatural Millivolt Hi/Lo33,00023,100 UVS43RPPropane Millivolt Hi/Lo33,00024,750

Gas Supply Pressures

This heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure equal to or less than 1/2 psig (3.45 kPa).

The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).

Connect the Gas Line

If gas piping from the source to the heater location has not been accomplished, install the required pipe. Con- sult local plumbing code to assure proper pipe size.

The gas pipeline can be brought in through the right or left side of the heater, as well as the bottom. Knockouts are provided at convenient locations to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the right side, as this allows fan installation or removal without disconnecting the gas line.

UnitsB42A00, B42B00, D42A00, D42B00, B41AS0, B41BS0, D41AS0, D41BS0
CFM UVS36 — Connect the Gas Line diagram (page 7)
Fig. 9 · Connect the Gas Line
Gas Inlet and Manifold Pressures NaturalLP Minimum Inlet Pressure5.5" w.c.11.0" w.c. Maximum Inlet Pressure 14.0" w.c.14.0" w.c. Manifold Pressure3.5" w.c10.0" w.c.

20000135

Page 8 of the CFM UVS36 user manual — Electrical Connection
Page 8 · click to enlarge
Page 8

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

CFM UVS36 — EB1 (Receptacle) Hook-Up diagram (page 8)
Fig. 10 · EB1 (Receptacle) Hook-Up

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control.

When using copper or flex connector use only approved fittings. Always provide a union so the gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater. (Fig. 7)

Fig. 8 Wiring diagram.

EB1 (Receptacle) Hook-Up

1. Remove 2" knockout. Slide the electrical box back plate into the back and bottom lances (clips) while fitting the box connector into the knockout. Fasten into place with fastening screws provided. (Fig. 9) 2. Connect the black positive wire to brass screw (polarized side) of the receptacle. The white wire is connected to the chrome screw. The ground wire is connected to the green ground screw of the receptacle. Fit the receptacle into the electrical box.
CFM UVS36 — EB1 (Receptacle) Hook-Up diagram (page 8)
Fig. 11 · EB1 (Receptacle) Hook-Up
3. Screw the cover plate provided to the electrical box.
CFM UVS36 — EB1 (Receptacle) Hook-Up diagram (page 8)
Fig. 12 · EB1 (Receptacle) Hook-Up

Fig. 7 Typical gas supply installation.

Electrical Connection

When installed, the heater must be electri- cally connected and grounded in accor- dance with local codes or, in the absence of local codes:

U.S. Installations: Follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Be sure to leave sufficient excess wire in case minor adjustments are required.

Any electrical re-wiring of this fan must be done by a qualified electrician.

Whether wiring directly to the fan junction box or into the EB1 (electrical receptacle box, P/N ZA1200) first ensure cable is secured using box connector.

CFM UVS36 — Electrical Connection diagram (page 8)
Fig. 13 · Electrical Connection

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan con- nects back to white supply wire. (Fig. 8)

20000135

Page 9 of the CFM UVS36 user manual — Finishing
Page 9 · click to enlarge
Page 9
2. Attach wire to switch and install switch into receptacle box. Attach cover plate to switch.

Slide the Heater in Place

3. Connect wiring to gas valve. (Fig. 10)

With the electrical and wall switch wiring connected, gently slide or lift the heater to the desired location.

CFM UVS36 — Slide the Heater in Place diagram (page 9)
Fig. 14 · Slide the Heater in Place

Level and Secure the Heater

If nailing flanges are not already installed, attach flanges with the screws provided.

Make sure heater is level. Shimming may be required.

Secure heater in place by nailing or screwing through nailing flanges into framing. NOTE: Be sure to allow proper space for sheet rock.

Fig. 10 Remote switch wiring.

Finishing

Alternate Switch Location

Remote switch can be installed on either side of the access door. Simply mount the switch to the switch bracket provided. Screw the bracket on either side of the frame, lining up the screws with the pre-punched holes. (Fig. 11)

When finishing the heater, never obstruct or modify the air inlet/outlet top or bottom grilles in any manner.

CFM UVS36 — Finishing diagram (page 9)
Fig. 15 · Finishing

Finish the wall with the material of your choice. Refer to Page 5, Figure 3 for specific clearances when installing a combustible mantel or other combustible projection.

Fig. 11 Installing remote switch bracket.

20000135

Page 10 of the CFM UVS36 user manual — Glass Cleaning
Page 10 · click to enlarge
Page 10

Operating Instructions

Glass Information

  • Only glass approved by CFM Specialty Home Products should be used on this fireplace.
  • The use of any non-approved replacement glass will void all product warranties.
  • Care must be taken to avoid breakage of the glass.
  • Do not operate appliance with glass front removed, cracked or broken.
  • Replacement glass (complete with gasket) is available through your CFM Specialty Home Products dealer and should only be installed by a licensed qualified service person.

DV34-2

Louvre Removal

Pull Clamp Hook Push Clamp Hook

To remove the top louvre (grille), lift lou- vre up and then out. (Fig. 12)

Fig. 13 Window Frame installation and removal.

cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depend- ing on the circumstances present.

Clean glass after first two weeks of opera- tion.

Fig. 12 Louvre installation and removal.

Log Installation

Window Frame Assembly Removal

Refer to Figures 14 and 15 for correct log placement.

1. Shut off gas. (See Lighting Instructions) 2. Let the unit cool if it has been operating. 3. Remove top louvre. (See Top Louvre Removal) 4. Open the bottom louvre assembly. 5. Release the two clamps at the bottom of the window frame by pulling down on the clamp handles. 6. Lift off the window frame assembly as shown in Figure 13. 7. To reinstall window frame assembly follow the above procedure in reverse. (Fig. 13)
1. Remove window frame assembly. (See "Window Frame Assembly" section) 2. Remove logs from packaging.

As with all plastic - these are not toys and should be kept away from children and infants.

3. Place rear log (BE8 or BF10) on rear bracket (ensure log is seated properly, leveled and centered to the unit), so it will not move from side to side and it is firmly positioned on the bracket. 4. Place front left log (BE6 or BF8) on top of burner, left side. Use log's bottom holes to locate it onto the left bracket log locator studs. 5. Place front right log (BE7 or BF9) on top of burner, right side. Use log's bottom holes to locate it onto the left bracket log locator studs. 6. Place ember material on top of burner. (See "Ember Material Placement" section).

Glass Cleaning

It will be necessary to clean the glass periodically. Dur- ing start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also, initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with anon-ammonia household

Show 8 more labels / short text on this page
(UVC Only) · Fireplace Front · Clamps · Window Frame Assembly · Window Frame As- sembly · Grille (Louvre) · Window Frame Assembly · 20000135
Page 11 of the CFM UVS36 user manual — Flame Adjustment
Page 11 · click to enlarge
Page 11
7. Place top left log (BE9 or BF11) onto locator notches. Ensure log is secure. 8. Place top right log (BE10 or BF12) onto locator notches. Ensure log is secure.
CFM UVS36 — Flame Characteristics diagram (page 11)
Fig. 16 · Flame Characteristics
CFM UVS36 — Flame Characteristics diagram (page 11)
Fig. 17 · Flame Characteristics

Fig. 16 Flame adjustment knob for Honeywell Valve.

Flame Characteristics

It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the Figures 17 or 18. If the flame patterns appear abnor- mal, contact a qualified service provider for service and adjustment.

Fig. 14 UVC/UVS36 log placement.

CFM UVS36 — Flame Characteristics diagram (page 11)
Fig. 18 · Flame Characteristics
CFM UVS36 — Flame Characteristics diagram (page 11)
Fig. 19 · Flame Characteristics

Fig. 15 UVC/UVS43 log placement.

Ember Material Placement

Separate the ember material into small pieces and place onto the burner in front of the front logs. Do NOT pack down, leave in fluffy, loose condition for most re- alistic ember effects. Do not install more embers on the burner than come with the unit.

Application of excess loose material may adversely affect performance of theheater.

Replacement loose embers must be purchased through authorized Majestic Fireplaces dealers.

Fig. 18 Approximate flame heights for each model.

Lava Rock

First Firing

The lava rock provided with this fireplace must be placed on the firebox bottom on either side of the burner assembly. Do not place lava rock in combustion pan.

Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the heater will not require such purging.

Under no circumstances should this lava rock be placed on any part of the burner assembly.

Flame Adjustment

When lit for the first time, the appliance will emit a slight odor for awhile. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disap- pears within a few minutes of burning.

For fireplaces equipped with HI/LO valves, flame ad- justment is accomplished by rotating the HI/LO adjust- ment knob located near the center of the gas control. (Fig. 16)

20000135

Page 12 of the CFM UVS36 user manual — To Turn Off Gas To Heater
Page 12 · click to enlarge
Page 12

Lighting And Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A. This heater has a pilot which must be lit manu-

  • If you cannot reach your gas supplier, call the Fire Department C. Use only your hand to push in or turn the gas

ally. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater

control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

  • area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any fireplace
  • Do not touch any electric switch
  • Do not use any phone in your building
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clockwise to "OFF".
10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

P

O

T

PILOT

OFF

F

F P

F

ON

ON

O

F

O

F

O

F

Euro SIT SIT NOVA Honeywell

  • If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
  • If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13. For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting. 14. Turn on all electrical power to the fireplace.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counterclockwise to "PILOT".

To Turn Off Gas To Heater

1. Turn the On/Off switch to Off position or set the thermostat to lowest setting. 2. Turn off all electric power to the fireplace if service is to be performed.
3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel.
Show 4 more labels / short text on this page
3/8" - 1/2" · o · t · 20000135
Page 13 of the CFM UVS36 user manual — NO
Page 13 · click to enlarge
Page 13

Troubleshooting

Nova SIT 820

START

CHECK

  • Gas Supply On
  • Supply line hooked up
  • Shutoff valve open NO

YES

  • Lockout has engaged. Wait 60 seconds and try again
  • For spark at electrode while depressing Piezo 1/8" gap to pilot hood needed
  • All wiring connections
  • Replace Piezo ignitor

Pilot Lights with Piezo Ignitor

NO

YES

  • For air in lines
  • Thermopile needs a minimum 325mV. Adjust pilot flame height
  • All wiring connections
  • Replace Thermopile
  • Thermocouple needs a minimum of 14mV.
  • Defective valve. turn to pilot, meter should read greater than 100mV. If not, replace

NO

YES

  • Valve is turned on
  • Wall switch is not turned on. Watch for grounded wires!
  • Thermopile needs a minimum 325mV.
  • Plugged burner orifice

Pilot Lights Main Burner

NO

YES

FP396A

Pilot Stays Lit · System OK · 20000135

Page 14 of the CFM UVS36 user manual — Cleaning Catalytic Filters
Page 14 · click to enlarge
Page 14

Maintenance

Burner and Burner Compartment

It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual.

Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.

The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.

Fig. 19 Proper pilot flame height.

Cleaning Catalytic Filters

Cleaning the Standing Pilot

(UVC Only)

Control System

The catalytic filters require cleaning at least once a year to work effectively.

The burner and control system consists of:

To clean catalytic filters:

  • main burner
  • pilot burner
  • gas orifice
  • thermopile
  • combination millivolt gas valve
1. From inside the combustion area, remove the 4 hex nuts holding the filter; lower filter down and out. 2. Clean the outer surface of the filter with the brush attachment of your vacuum sweeper to remove loose dirt. 3. Submerge the filter in a mild soapy water solution, then rinse thoroughly with distilled or deionized water. 4. Replace in heater when dry. 5. Repeat with second filter.

Most of these components may require only an occa- sional checkup and cleaning and some may require ad- justment. If repair is necessary, it should be performed by a qualified technician.

In order to properly clean the burner and pilot assembly, turn off the gas to the unit, remove the window frame panel and logs exposing the burner and pilot assembly. Clean all foreign materials from the top of the burner. Check to make sure that burner parts are clean. Visu- ally inspect pilot. Brush or blow away any dust or lint accumulation If pilot orifice is plugged, disassembly may be required to remove any foreign material from the orifice or tubing.

To obtain proper operation, it is imperative that the pilot and burner's flame characteristics are steady, not lifting or floating.

Typically, the top 1/8" of the thermopile should be en- gulfed in the pilot flame. (Fig. 19)

Pilot Assembly · FK24 Fan Assembly · 20000135

Page 15 of the CFM UVS36 user manual — Maintenance
Page 15 · click to enlarge
Page 15
CFM UVS36 — Maintenance diagram (page 15)
Fig. 20 · Maintenance

CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVC/UVS 36/43 Vent Free Heaters

CFM UVS36 — Maintenance diagram (page 15)
Fig. 21 · Maintenance

1. Log Set Complete 10000547 10000547 10000562 10000562 1a. Log Front Left BE6 BE6 BF8 BF8 1b. Log Front Right BE7 BE7 BF9 BF9 1c. Log Rear BE8 BE8 BF10 BF10 1d. Log Top Left BE9 BE9 BF11 BF11 1e. Log Top Right BE10 BE10 BF12 BF12 2. Lava Rock Package 55255 3. Ember Package 10000550 4a. Burner with Tiles - Natural 20000075 20000075 20000111 20000111 4b. Burner with Tiles - LP 10000555 10000555 10000152 10000152 5. Ceramic Tile (Single) 57803

20000135

Page 16 of the CFM UVS36 user manual — Maintenance
Page 16 · click to enlarge
Page 16

UVC/UVS 36/43 Vent Free Heaters (continued) Ref. Description UVC36 UVS36 UVC43 UVS43 6a. Orifice Main Burner - Natural See Rating Plate for Orifice Size 6b. Orifice Main Burner - LP See Rating Plate for Orifice Size 7. Fan with Bracket (FK24) 54103 8. Electrical Cord (6ft.) 51865 51865 51865 58165 9. Fan Temperature Sensor 51704 10. Speed Control 51738 11. Speed Control Knob 51882 12. Glass with Gasket 55686 - 57438 - 13. Gasket Glass 57317 - 57317 - 14. Frame Window 57937 - 57977 - 15. Frame Window w/Screen - 10000148 - 10000153 16. Access Door Hinge 52356 17. Louvre Top Assembly 10000037 10000037 10000041 10000041 18. Louvre Bottom Assembly 10000038 10000038 10000042 10000042 19. Pilot Tubing w/Fittings 10000150 20a. Pilot Assembly - Natural ODS 55464 20b. Pilot Assembly - LP ODS 10001647 10001647 55465 55465 21. Ignitor Piezo 52464 22. Cable Ignitor 20000101 23a. Valve Nova - Natural 55463 23b. Valve Nova - LP 55462 24. Manifold Tubing w/Fittings 57318 25. Clamp Frame Window 54174 26. CO Catalyst Filter 55629 - 55629 - 27. Bracket CO Catalyst Holder 56255 - 56255 - 28. Remote Switch 51842 29. Remote Switch Kit (Not Shown) 53875 30. O.S.A. Assy 3547900

Contact CFM Specialty Home Products for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fire- places distributor or dealer.

Model and serial numbers are listed on the rating plate (located on right side of combustion cham- ber).

You will need the following information when ordering replacement parts:

Record your model and serial numbers here for future reference:

1. The heater model number. 2. The serial number. 3. A description of the part.

Should you need additional information beyond what your dealer can furnish, contact:

CFM Specialty Home Products 410 Admiral Blvd. Mississauga, Ontario Canada, L5T 2N6

Model # Serial # 20000135

Page 17 of the CFM UVS36 user manual — Hard (Direct) Wire Hook-Up
Page 17 · click to enlarge
Page 17

Optional Accessories

Fan Kit

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hook-up.

Fan specifications120 volt, 60 Hz, .75 Amps

This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season. Should this fan require servicing, the power supply must be disconnected.

The FK-24 comes with the electrical cord attached.

1. Slide fan assembly from the left side into the fireplace opening, line up mounting holes with screw studs on back of fireplace and fasten with #10-24 hex nuts.

Fig. 20 FK-24 wiring.

2. Install thermal sensor on bottom of firebox using #10-24 hex nuts.

Remote Controls

Optional remote control units are available to control different functions of the appliance.

3. (Option A) - Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes with screw studs. Fasten fan speed control box with #10-24 hex nuts.

Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital and a programmable 24 hour clock IMT Wall mounted thermostat control

(Option B) - The speed control can be installed in an electrical box at normal wall switch height for convenient access.

4. The power supply may be connected in 2 ways: Method A - route the 6' (1.8m) lead fitted to the unit to a conveniently located wall socket.

Ceramic Refractory Panels

Method B - If the EB-1 receptacle box (Pt. #ZA1200) was correctly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.

Ceramic refractory panels are available to line the fire- box area.

Unit Kit Model UVC36 UV36CR UVS36 UV36CR UVC43 UV43CR UVS43 UV43CR

5. Whether wiring directly to the fan junction box, (Option A) or into the EB-1 (Option B), first ensure cable is secured using box connector.

The fireplace, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Take care when handling the refractory panels as they are fragile until held in place and supported.

Arched Door Front

The arched door front kit is designed to visually en- hance the appearance of the UVC36 fireplace only.

Hard (Direct) Wire Hook-Up

DV36ADKP Polished Brass DV36ADKA Antique Brass

First connect the ground wire to the ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Al- ternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 20)

Show 6 more labels / short text on this page
FK24 Fan Assembly · Fan Temperature Sensor · Speed Control · Black White · Ground · 20000135
Page 18 of the CFM UVS36 user manual — Outside Air Termination
Page 18 · click to enlarge
Page 18

Decorative Frame Trims

A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit.

Unit Kit Model UVC/UVS36 DV36GTP/DV36GTA DV36TKP/DV36TKA DV36KMP/DV36KMA DV36KWP/DV36KWA UVC/UVS43 DV43GTP/DV43GTA DV43TKP/DV43TKA DV43KMP/DV43KMA DV43KWP/DV43KWA

Fig. 21 Bay window.

Decorative Bay Window

Available for the UVC36 only.

EB-1 Electrical Box

When fitting the Bay Window Kit, the original front frame/glass assembly MUST remain in place. The Bay Window Kit is fitted over the existing front glass.

Junction box for fan installations.

Outside Air Termination

The AK-1 completes the connection from outside air kit to out-of-doors. (Does not include 4" flex duct.)

1. Remove the existing louvre assembly bottom complete with the hinges. 2. Remove the louvre assembly top. 3. Assembly the Bay Window Kit according to the instructions supplied with the kit. 4. Place the 2 pieces of ceramic refractory along the base of the bay window. (Fig. 21) 5. Hang the bay window assembly over the existing window frame assembly. 6. Reinstall the louvre assembly top. 7. Do not remove the existing window frame assembly.
Show 10 more labels / short text on this page
Louvre Assem- bly Top · Bay Window Frame · Ceramic Refractory · Ceramic Refractory · Spacers · Louvre Assembly Bottom · Bottom Brass Trim · Screws · Installation · 20000135
Page 19 of the CFM UVS36 user manual — IF WARRANTY SERVICE IS NEEDED…
Page 19 · click to enlarge
Page 19

LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame

BASIC WARRANTY

CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.

  • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest.
  • This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection.
  • The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s)
  • Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law.
  • SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
  • All other warranties-expressed or impliedwith respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.
  • The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product
  • The warranties as outlined within this document do not apply to chimney components or other non CFM Specialty Home Products accessories used in conjunction with the installation of this product..
  • Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier).
  • The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such

EXTENDED LIFETIME WARRANTY

The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.

BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.

GAS VALVESGas valves are covered for a period of one year

ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.

as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by

ACCESSORIES: Unless otherwise noted all components and CFM Specialty Home Products company supplied accessories are covered for a period of one year.

mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by

CONDITIONS AND LIMITATIONS

chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of

  • This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.
  • This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company.
  • The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop.
  • If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor.

dampness or condensation c) Any damages to the fireplace, combustion chamber, heat

exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1. Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Specialty Home Products product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.

20000135

Page 20 of the CFM UVS36 user manual — CFM Specialty Home Products
Page 20 · click to enlarge
Page 20
CFM UVS36 — CFM Specialty Home Products diagram (page 20)
Fig. 22 · CFM Specialty Home Products

CFM Specialty Home Products

  • 410 Admiral Blvd.
  • Mississauga, Ontario, Canada L5T 2N6
  • 905-670-7777 <a href="http://www.majesticproducts.com" rel="nofollow noopener" target="_blank">www.majesticproducts.com</a>
  • <a href="http://www.vermontcastings.com" rel="nofollow noopener" target="_blank">www.vermontcastings.com</a>
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the CFM UVS36

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the CFM UVS36

Be the first to ask — other owners or our team will answer.

Original document

CFM UVS36 manual PDF

20 pages·993 KB·Fan·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…