PLEASE READ THIS MANUAL BEFORE INSTALLING AND US- ING APPLIANCE.
Models: UVC36 / UVS36 UVC43 / UVS43
or other flammable vapors and liquids in the vicinity of this or any other appliance.
Operating Manual
be performed by a qualified installer, service agency or the gas supplier.
D
E
G
N
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combus- tion and ventilation air must be provided. Refer to Page 4.
D
R
T
F
E
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
20000135 9/05 Rev. 4



This gas room heater should be installed by a qualified installer in accordance with local building codes and with current Na- tional Fuel Gas Code. ANSI Z223.1/NFPA 54. "This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air". "The National Fuel Gas Code, ANSI Z233.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the ag- gregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space.. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space of if the build- ing is of unusually tight construction, provide adequate combus- tion and ventilation air by one of the methods, described in the National Fuel Gas Code, ANSI Z 223.1/NFPA 54, Section 5.3 or applicable local codes." Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed, and b) Weather stripping has been added on openable windows and doors, and c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
FOR SAFE INSTALLATION AND OPERATION OF YOUR VER- MONT CASTINGS MAJESTIC PRODUCTS COMPANY VENT- FREE ROOM HEATER PLEASE NOTE THE FOLLOWING: 1. This heater gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of the high temperatures surface of this heater and should stay away to avoid burns or ignition of clothing. 3. Young children should be carefully supervised when they are in the same room as your heater. 4. Under no circumstances should this heater be modified. Parts removed for service should be replaced prior to oper- ating this heater again. 5. Installation repair to this heater should be done by a quali- fied service person. A professional service person should be contacted to inspect this heater annually. Make it a practice to have all of your gas heaters checked annually. More fre- quent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this heater should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit. 7. Under no circumstances should any solid fuels (wood, coal, paper or cardboard, etc.) be used in this heater. 8. Keep the area around your heater clear of combustible ma- terials, gasoline and other flammable vapor and liquids. This heater should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung in the area of it. 9. Whether the heater is installed directly on carpeting, vinyl tile or any combustible material other than wood, this heater must be installed on a metal or wood panel extending the full width and depth of the heater. 10. Do not install heater in bedroom or bathroom. 11. Do not place clothing or other flammable material on or near the appliance. 12. Any safety screen or guard removed for servicing an appli- ance must be replaced prior to operating the heater. 13. Do not use this room heater if any part has been under water.
Fireplace screen (when equipped) must be closed while the appliance is in operation. WARNING: Do not allow LP tank below 1/4 full. WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame pat- terns. WARNING: Do not use a blower insert, heat exchanger or other accessory not approved for use with this heater. WARNING: Any change to this heater or its controls can be dangerous.
This appliance is intended for supplemental heating.
Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile home), where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
20000135


Rough Opening Width 36¹⁄₂" Finished Wall Thickness
5³⁄₄" 3¹⁄₄" 7³⁄₄" 2"
Fig. 1 UVC/UVS36 specifications and framing.

Rough Opening Width 43¹⁄₂" Finished Wall Thickness
Fig. 2 UVC/UVS43 specifications and framing.
20000135


It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.
Please ensure that your room is well ventilated - open all windows.
It is recommended that you burn your Vermont Castings Majestic Products fireplace for a least six (6) hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.
Adequate combustion and ventilation air must be pro- vided. The flow of combustion and ventilation air MUST NOT be obstructed.
Provide adequate clearances around the air opening into the combustion chamber; and adequate accessibili- ty clearance for servicing and proper operation. NEVER obstruct the front opening of the heater or cover the top and bottom louvres (grilles).
Fig. 3a Combustible mantel minimum installation.
These heaters are equipped with a pilot system fea- turing an Oxygen Depletion Sensor (O.D.S.) shut-off device. All unvented heaters are required to have this system. The O.D.S. pilot will shut down the heater when there is not enough fresh air available.
F G H I
Report any parts damaged in shipment to your dealer.
K Side of Combustion Chamber
The UVC vent-free heaters are unique in featuring two catalytic filters and a frame window with glass that actually clean room air as well as give excellent zone heating.
N
O
The UVS vent-free heaters use a frame window with screen mesh that does not use any catalytic filters.
Each model is available as Natural or Propane gas, equipped with a standing pilot.
Design-certified to ANSI Z21.11.2a-2003. Gas-Fired Room Heaters — Vol. II, Unvented Room Heaters.
Top of unit to ceiling 36" (914 mm) Front of unit to combustibles 36 (914 mm) Appliance Top 0" (0 mm) Bottom 0" (0 mm) Sides 0" (0 mm) Back 0" (0 mm) Perpendicular sidewall 6" (152 mm)
Mantel Mantel Leg From Side Ref. Leg Depth Ref. of Comb. Opening F 10" (254 mm) K 11¹⁄₂" (292 mm) G 8" (203 mm) L 9¹⁄₂" (241 mm) H 6" (152 mm) M 7¹⁄₂" (191 mm) I 4" (101 mm) N 5¹⁄₂" (101 mm) J 2" ( 51 mm) O 3¹⁄₂" (89 mm)
Fig. 3b Combustible mantel leg minimum installation.
Mantel Leg · CFM164a · 20000135


Depending on the width of the mantel it may be in- stalled higher or lower from the combustion chamber opening. This also applies to the distance between the mantel leg (if installed) and the fireplace. Refer to Fig- ures 3a and 3b for correct mounting heights and widths for combustible mantels and mantel legs.
Scew Drywall Position Depths A 1/2" (13 mm) B 5/8" (16 mm) C 3/4" (19 mm)
Noncombustible mantels and legs may be installed at any height above the appliance opening.

When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discoloration.
Fig. 4 Adjustable drywall strip (nailing flange).
A hearth extension in front of heater is recommended but not required.
Framing can take place before or after the heater is set in place. The framing should be positioned to accom- modate the wall covering and facing material. Framing material should be 2x4 or heavier. Framing headers may rest on top of heater. (Refer to Page 4, Figures 1 and 2 for heater and framing dimensions.)
Planning the installation is an important first step: it will save time and money later in the actual installation. In planning the installation, consider:
When a heater is installed in a chase or an outside wall, the enclosure should be insulated like any other wall of the home. Insulation should be installed under the heater and on the inside of the exterior walls. (Fig. 5)
The heater should only be mounted on the following surfaces:

To mount the heater:
Insulation methods shown are optional for cold climate, not a require- ment for unit operation.
1. Choose unit location. 2. Place unit in position and secure to floor with 1¹⁄₂" screws, or nails. The holes to secure the unit to the floor are located just behind the bottom louvre on the left and right hand side of the unit. 3. Frame in heater with a header across the top. It is important to allow for finished face when setting the depth of the frame. 4. Attach heater to frame using adjustable frame drywall strips (located behind access door for shipping). Preset depth to suit facing material (adjustable to 1/2" , 5/8" or 3/4" depths). (Fig. 4) 5. Use existing screws in side of unit to attach drywall strip. Measure from face of heater to face of drywall strip to determine final depth. (Fig. 4)
Fig. 5 Insulating for cold climates.
20000135


Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)
For elevations above 4,500 feet (1,370m), instal- lations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
The installation of your Majestic Fireplaces room- heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition. (EX- CEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas.)
Fig. 6 Parts identification.

This heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure equal to or less than 1/2 psig (3.45 kPa).
The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).
If gas piping from the source to the heater location has not been accomplished, install the required pipe. Con- sult local plumbing code to assure proper pipe size.
The gas pipeline can be brought in through the right or left side of the heater, as well as the bottom. Knockouts are provided at convenient locations to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the right side, as this allows fan installation or removal without disconnecting the gas line.

20000135

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved fittings. Always provide a union so the gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater. (Fig. 7)
Fig. 8 Wiring diagram.


Fig. 7 Typical gas supply installation.
When installed, the heater must be electri- cally connected and grounded in accor- dance with local codes or, in the absence of local codes:
U.S. Installations: Follow local codes and the National Electrical Code, ANSI/NFPA No. 70.
Be sure to leave sufficient excess wire in case minor adjustments are required.
Any electrical re-wiring of this fan must be done by a qualified electrician.
Whether wiring directly to the fan junction box or into the EB1 (electrical receptacle box, P/N ZA1200) first ensure cable is secured using box connector.

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan con- nects back to white supply wire. (Fig. 8)
20000135

With the electrical and wall switch wiring connected, gently slide or lift the heater to the desired location.

If nailing flanges are not already installed, attach flanges with the screws provided.
Make sure heater is level. Shimming may be required.
Secure heater in place by nailing or screwing through nailing flanges into framing. NOTE: Be sure to allow proper space for sheet rock.
Fig. 10 Remote switch wiring.
Alternate Switch Location
Remote switch can be installed on either side of the access door. Simply mount the switch to the switch bracket provided. Screw the bracket on either side of the frame, lining up the screws with the pre-punched holes. (Fig. 11)
When finishing the heater, never obstruct or modify the air inlet/outlet top or bottom grilles in any manner.

Finish the wall with the material of your choice. Refer to Page 5, Figure 3 for specific clearances when installing a combustible mantel or other combustible projection.
Fig. 11 Installing remote switch bracket.
20000135

Louvre Removal
Pull Clamp Hook Push Clamp Hook
To remove the top louvre (grille), lift lou- vre up and then out. (Fig. 12)
Fig. 13 Window Frame installation and removal.
cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depend- ing on the circumstances present.
Clean glass after first two weeks of opera- tion.
Fig. 12 Louvre installation and removal.
Window Frame Assembly Removal
Refer to Figures 14 and 15 for correct log placement.
As with all plastic - these are not toys and should be kept away from children and infants.
3. Place rear log (BE8 or BF10) on rear bracket (ensure log is seated properly, leveled and centered to the unit), so it will not move from side to side and it is firmly positioned on the bracket. 4. Place front left log (BE6 or BF8) on top of burner, left side. Use log's bottom holes to locate it onto the left bracket log locator studs. 5. Place front right log (BE7 or BF9) on top of burner, right side. Use log's bottom holes to locate it onto the left bracket log locator studs. 6. Place ember material on top of burner. (See "Ember Material Placement" section).
It will be necessary to clean the glass periodically. Dur- ing start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also, initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with anon-ammonia household



Fig. 16 Flame adjustment knob for Honeywell Valve.
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the Figures 17 or 18. If the flame patterns appear abnor- mal, contact a qualified service provider for service and adjustment.
Fig. 14 UVC/UVS36 log placement.


Fig. 15 UVC/UVS43 log placement.
Separate the ember material into small pieces and place onto the burner in front of the front logs. Do NOT pack down, leave in fluffy, loose condition for most re- alistic ember effects. Do not install more embers on the burner than come with the unit.
Application of excess loose material may adversely affect performance of theheater.
Replacement loose embers must be purchased through authorized Majestic Fireplaces dealers.
Fig. 18 Approximate flame heights for each model.
First Firing
The lava rock provided with this fireplace must be placed on the firebox bottom on either side of the burner assembly. Do not place lava rock in combustion pan.
Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the heater will not require such purging.
Under no circumstances should this lava rock be placed on any part of the burner assembly.
When lit for the first time, the appliance will emit a slight odor for awhile. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disap- pears within a few minutes of burning.
For fireplaces equipped with HI/LO valves, flame ad- justment is accomplished by rotating the HI/LO adjust- ment knob located near the center of the gas control. (Fig. 16)
20000135

may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.
O
T
PILOT
OFF
F
F P
F
ON
ON
O
F
O
F
O
F
Euro SIT SIT NOVA Honeywell

Nova SIT 820
CHECK
Pilot Lights with Piezo Ignitor
YES
YES
Pilot Lights Main Burner
YES
FP396A
Pilot Stays Lit · System OK · 20000135

Burner and Burner Compartment
It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual.
Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.
The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.
Fig. 19 Proper pilot flame height.
Cleaning the Standing Pilot
(UVC Only)
Control System
The catalytic filters require cleaning at least once a year to work effectively.
The burner and control system consists of:
To clean catalytic filters:
Most of these components may require only an occa- sional checkup and cleaning and some may require ad- justment. If repair is necessary, it should be performed by a qualified technician.
In order to properly clean the burner and pilot assembly, turn off the gas to the unit, remove the window frame panel and logs exposing the burner and pilot assembly. Clean all foreign materials from the top of the burner. Check to make sure that burner parts are clean. Visu- ally inspect pilot. Brush or blow away any dust or lint accumulation If pilot orifice is plugged, disassembly may be required to remove any foreign material from the orifice or tubing.
To obtain proper operation, it is imperative that the pilot and burner's flame characteristics are steady, not lifting or floating.
Typically, the top 1/8" of the thermopile should be en- gulfed in the pilot flame. (Fig. 19)
Pilot Assembly · FK24 Fan Assembly · 20000135


CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVC/UVS 36/43 Vent Free Heaters

1. Log Set Complete 10000547 10000547 10000562 10000562 1a. Log Front Left BE6 BE6 BF8 BF8 1b. Log Front Right BE7 BE7 BF9 BF9 1c. Log Rear BE8 BE8 BF10 BF10 1d. Log Top Left BE9 BE9 BF11 BF11 1e. Log Top Right BE10 BE10 BF12 BF12 2. Lava Rock Package 55255 3. Ember Package 10000550 4a. Burner with Tiles - Natural 20000075 20000075 20000111 20000111 4b. Burner with Tiles - LP 10000555 10000555 10000152 10000152 5. Ceramic Tile (Single) 57803
20000135

UVC/UVS 36/43 Vent Free Heaters (continued) Ref. Description UVC36 UVS36 UVC43 UVS43 6a. Orifice Main Burner - Natural See Rating Plate for Orifice Size 6b. Orifice Main Burner - LP See Rating Plate for Orifice Size 7. Fan with Bracket (FK24) 54103 8. Electrical Cord (6ft.) 51865 51865 51865 58165 9. Fan Temperature Sensor 51704 10. Speed Control 51738 11. Speed Control Knob 51882 12. Glass with Gasket 55686 - 57438 - 13. Gasket Glass 57317 - 57317 - 14. Frame Window 57937 - 57977 - 15. Frame Window w/Screen - 10000148 - 10000153 16. Access Door Hinge 52356 17. Louvre Top Assembly 10000037 10000037 10000041 10000041 18. Louvre Bottom Assembly 10000038 10000038 10000042 10000042 19. Pilot Tubing w/Fittings 10000150 20a. Pilot Assembly - Natural ODS 55464 20b. Pilot Assembly - LP ODS 10001647 10001647 55465 55465 21. Ignitor Piezo 52464 22. Cable Ignitor 20000101 23a. Valve Nova - Natural 55463 23b. Valve Nova - LP 55462 24. Manifold Tubing w/Fittings 57318 25. Clamp Frame Window 54174 26. CO Catalyst Filter 55629 - 55629 - 27. Bracket CO Catalyst Holder 56255 - 56255 - 28. Remote Switch 51842 29. Remote Switch Kit (Not Shown) 53875 30. O.S.A. Assy 3547900
Contact CFM Specialty Home Products for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fire- places distributor or dealer.
Model and serial numbers are listed on the rating plate (located on right side of combustion cham- ber).
You will need the following information when ordering replacement parts:
Record your model and serial numbers here for future reference:
Should you need additional information beyond what your dealer can furnish, contact:
CFM Specialty Home Products 410 Admiral Blvd. Mississauga, Ontario Canada, L5T 2N6
Model # Serial # 20000135

Any electrical rewiring of this fan must be completed by a qualified electrician.
Turn off all power before hook-up.
This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season. Should this fan require servicing, the power supply must be disconnected.
The FK-24 comes with the electrical cord attached.
Fig. 20 FK-24 wiring.
Optional remote control units are available to control different functions of the appliance.
Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital and a programmable 24 hour clock IMT Wall mounted thermostat control
(Option B) - The speed control can be installed in an electrical box at normal wall switch height for convenient access.
Method B - If the EB-1 receptacle box (Pt. #ZA1200) was correctly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.
Ceramic refractory panels are available to line the fire- box area.
Unit Kit Model UVC36 UV36CR UVS36 UV36CR UVC43 UV43CR UVS43 UV43CR
The fireplace, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.
Take care when handling the refractory panels as they are fragile until held in place and supported.
The arched door front kit is designed to visually en- hance the appearance of the UVC36 fireplace only.
DV36ADKP Polished Brass DV36ADKA Antique Brass
First connect the ground wire to the ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Al- ternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 20)

A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit.
Unit Kit Model UVC/UVS36 DV36GTP/DV36GTA DV36TKP/DV36TKA DV36KMP/DV36KMA DV36KWP/DV36KWA UVC/UVS43 DV43GTP/DV43GTA DV43TKP/DV43TKA DV43KMP/DV43KMA DV43KWP/DV43KWA
Fig. 21 Bay window.
Available for the UVC36 only.
When fitting the Bay Window Kit, the original front frame/glass assembly MUST remain in place. The Bay Window Kit is fitted over the existing front glass.
Junction box for fan installations.
The AK-1 completes the connection from outside air kit to out-of-doors. (Does not include 4" flex duct.)

LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame
CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by
ACCESSORIES: Unless otherwise noted all components and CFM Specialty Home Products company supplied accessories are covered for a period of one year.
mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by
chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of
dampness or condensation c) Any damages to the fireplace, combustion chamber, heat
exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
20000135