Instruction/ maintenance manual of the product GB2P Cecilware
Go to page of 18
CAPPUCCINO, COFFEE, and SOUP DISPENSERS GB POUROVER models : •GB1P •GB2P •GB3P •GB4P OPERA TION MANUAL • Specifications 2 • Installation and Operating Instructions 3 • Adjustments 4 • .
Electrical Specifications Model No. Volts Phase Hz Watts Number of Heaters Amps Receptacle Nema No. Circuit Breaker GB1P, GB2P, GB3P GB4P 120V 1 60 1.8KW 1 15 5-15R 15A GB1P, GB2P, GB3P, GB4P 120/240V or 240V 1 50/60 50/60 3.0KW 3.0KW 1 15 15 L14-20R** L6-20R 20A 20A 120V, 1.
3 START UP INSTRUCTIONS FOR GB POUROVER CAPPUCCINO DISPENSER (see illustration 9-3 for clarification) I. INSTALLATION INSTRUCTIONS This equipment is to be inst alled to com ply with the applicable Fe deral, State, or l oca l p lumbing codes hav ing jurisdiction.
III. PRIMING - AUTOFILL - Water Selection Switch - To ggle Down (See B a ck Panel) 1. Plug into power outlet. 2. Turn Heater Switch ON. 3. Allow 10 to 15 minutes for water t o reach dispense temperat ure of 185°F. Heater Indicator Light (red) goes ON when heater is on (see lower front panel).
HOPPER COVER CD106 5 AUGER GEAR – FOR RE CTANGULAR HOPPE RS: CD117 [Used With Nylon Auger CD130] CD117 [Used With Wire Auger CD101 &CD130] FRONT BUSHING: Rectangular Hoppers: CD277 [ Ø 22.5 mm ] CD306 [ Ø 17 mm ] Square Hoppers: CD102 [ Ø 2 2.
DRINK SIZE ADJUSTMENTS (OPTIONAL FEATURE) a. Manual Dispen se Machines: Hold down the Dispense Button until desired amoun t is dispensed. b. Automatic Machines wit h Programmable "Teach m e" Timers [L576A or L582A]: The timer is progr amm able from the dispen se button.
TEST T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 A ) Water Inlet Valve Test Check Valve Ass’y L463A Check Valve Ass’y L463A Check Valve Ass’y L463A Turn power off.
TROUBLESHOOTING GUIDE FOR GB-POUROVER WARNING: To reduce the risk of electr ical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact.
9 MAINTENANCE To Replace The Picture / Duratr an GB w/ Metal Doors Only: Lift up the two end tabs o n top of door with a pointe d o bject or flat h ead screwdriver. Pull the entire pict ure frame out. Open up the two c lear pa nels and replac e picture.
10 CLEANING AND SANITIZING Sanitizing: All sanitizing agents in the food zone must comply with 21 CFR 178.1010. All food dispensing units should be sani tized periodically. All parts to be sanitize d must be cleaned first. To prepare a sanitizing solution: Add 2 Tsp.
RESERVOIR AND TANK ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 14 13 17 15 16 21 20 19 18 3 7 Q174Q RESERVOIR ASSEMBLY ITEM P/N QTY DESCRIPTION 1. Q174A 1 P.O.-LINE TANK(GB3M/ICAP) 2. L499P 1 FLOA T SWITCH 70-V-A 3. M461A 3 DIRECT MOUNTING SEAL (.466 ID) 4. K402A 1 LEVEL CONTROL, 5.
DESCRIPTION AND LOCATION OF COMPONENTS (GB3P SHOWN) CCW CCW CCW 15 19 17 10 11 13 12 14 9 23 22 26 25 24 27 31 30 29 28 33 34 32 37 36 35 39 38 42 40 41 46 47 45 44 7 8 1 62 61 52 50 51 48 53 58 57 59.
ITEM DESCRIPTION GB1P GB2P GB3P 1 WATER BOTTLE 3 gal / OR 6 gal M518A / M519A M518A / M519A M518A / M519A 2 RESERVOIR /COVER 97128 97128 97128 3 RESERVOIR ASSY Q174Q Q174Q Q174Q 4 SILICONE HOSE - RESE.
14 N L1 L1 L1 MAIN UNIT DOOR UNIT N N N N N N N N N N L1 L1.
15 N N L1 L1 N N N N N N N N L1 L1 L1 MAIN UNIT N DOOR UNIT + +.
16 L1 L1 DOOR U NIT N N N N N N N N N N N L1 L1 L1.
N N N N N N N N N N L1 L1 L1 L1 L1 N DOOR UNIT + + + MAIN UN IT 17.
N N N N N N N N N N L1 L1 L1 L1 L1 N DOOR UNIT + + MAIN UNIT 18.
An important point after buying a device Cecilware GB2P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cecilware GB2P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cecilware GB2P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cecilware GB2P you will learn all the available features of the product, as well as information on its operation. The information that you get Cecilware GB2P will certainly help you make a decision on the purchase.
If you already are a holder of Cecilware GB2P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cecilware GB2P.
However, one of the most important roles played by the user manual is to help in solving problems with Cecilware GB2P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cecilware GB2P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center