Go to page of 20
Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .
2 Important The CD A Group L td cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CD A reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment.
3 IMPORT ANT INFORMA TION FOR CORRECT DISPOSAL OF THE PRODUCT IN A CCORD ANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
4 Using your Extractor R emote Control A - LED lights B - “Plus” button C - “Light” button D - “Power” button E - “Clock” button F - “Minus ” button A E D C B F Fig.
5 T o switch the extractor on or o: • Press the “P ower” button “D” once . After switching on the motor will automatically start at the lowest speed setting. Setting the extractor speed when it is running: The extractor may run at a choice of 4 speeds, indicated by the LED lights on the remote control.
6 Care and Maintenance IMPORT ANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRA CT OR WITHOUT FIRST SWIT CHING OFF THE ELECTRICITY SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface.
7 T o remove the aluminium grease filters for cleaning • While supporting the weight of the lower half of the globe, use the special tool supplied with the appliance to unscrew the metal ring that secures it (Fig. 2). • Place the lower half of the globe, chrome lower cover and locking ring aside safely .
8 Changing the charcoal filter (Filter part number CHA30) T o ensure best performance of your extractor , you should replace the charcoal filter every four to six months, depending on use. T o replace the charcoal filters: • The charcoal filters are removed as part of the grease filter cleaning process described on the previous page.
9 If your extractor is not working: 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown. 3. There is a hidden on/o switch inside the body of the globe. Ensure that this has not been accidentally switched o during installation or maintenance.
10 The LED and Neon Lamps The LED lamps (3S10BL) and neon light tubes (3S10WH) are long-life items that are not designed to be replaced by the user . In the unlikely event of a lamp failure, contact CD A Customer Care for assistance.
11 • The wire which is coloured green and yellow must be connected to the terminal marked “E” (Earth) or coloured green. • The wire which is coloured blue must be connected to the terminal marked “N” (Neutral) or coloured black.
12 Mounting Y our Extractor This appliance is designed to recirculate air only , under no circumstances should it be connected to any ductwork or external venting system. When installing this appliance over a CD A hob, the clearance between the extractor and the hob must be equal to or ex ceed 650mm.
13 Installation 1. Thread the safety cable upward through the small hole in the ceiling plate then downward through the centre boss. Pull this tight so the end nipple rests against the ceiling plate (Fig. 6). 2. P ass the fix ed wiring from the ceiling through the large hole in the ceiling plate (shown as “ A ” in Fig.
14 2. R emove the chrome cover from the top of the sphere, then remove and discard the cylindrical packing piece from the top bracket within it (Fig. 8). 3. P ass the power cable that exits the appliance up through the central bracket within the sphere (Fig.
15 6. Select the smaller diameter hanging tube and pass it through the ceiling rose cover . Note that the end of the hanging tube with holes in it needs to be upper-most (Fig. 13). 7 . Thread the power cable from the sphere upward through the smaller diameter hanging tube.
16 Fig. 16 Fig. 17 Fig. 19 10 . With a second person supporting the weight of the sphere, thread the safety cable down the tube assembly (Fig. 16) so it exits within the top cavity of the sphere (Fig. 17). 11. Insert the top tube into the ceiling bracket and secure it with two supplied through-bolts and nuts (Fig 18).
17 11. With an assistant supporting the weight of the sphere, adjust the height by sliding the outer hanging tube up or down the inner one (Fig. 20). 12 Fix the height adjustment by locking the three grubscrews on the tube joining-piece (shown as in Fig.
18 Notes:.
19 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CDA reserve the right to change specifications without prior notice.
Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www. cda.eu www .cda.eu Please contact our Customer Care Department for Service on the details below Customer Care Department The Group L td.
An important point after buying a device CDA 3S10 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought CDA 3S10 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data CDA 3S10 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, CDA 3S10 you will learn all the available features of the product, as well as information on its operation. The information that you get CDA 3S10 will certainly help you make a decision on the purchase.
If you already are a holder of CDA 3S10, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime CDA 3S10.
However, one of the most important roles played by the user manual is to help in solving problems with CDA 3S10. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device CDA 3S10 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center