Installation and Maintenance Guide
A VAYA P460
M ULTILAYER M ODULAR S WITCH
S OFTWARE V ERSION 1.0
February 2003




Table 3.1 Environmental Requirements 4 Table 3.2 AC Power Requirements 5 Table 3.3 Dimensions 5 Table 5.1 Active M460ML-SPV LEDs 25 Table 5.3 Standby/Halted M460ML-SPV LEDs 26 Table 5.2 Active M460ML-SPV FastETH LED 26 Table 5.5 ACT and OPR LED Summary 27 Table 5.4 Standby M460ML-SPV FastETH LED 27 Table 5.6 M460ML-SPV Function LEDs 29 Table 5.7 M460ML-SPV Left and Right Pushbutton Functions 31 Table 5.8 Power Supply Status LED 33 Table 6.1 ACT and OPR LED Summary 35 Table 6.2 Sample Power Budget Calculation 40 Table 9.1 Access Level Descriptions 55 Table 10.1 Default System Parameters 61 Table 15.1 Avaya P460 Catalog Numbers 82
Avaya P460 Installation and Maintenance Guide v

vi Avaya P460 Installation and Maintenance Guide
List of Tables

Figure 3.1 The Avaya P460 Switch – Component Location 6 Figure 3.2 Table-Top Installation 7 Figure 3.3 P460 Front-Mount and Mid-Mount Positions (side view) 8 Figure 3.4 Positioning the rack-mounting brackets 9 Figure 3.5 Installing the Cable Guide 10 Figure 3.6 The Avaya P460 Switch – Fan Module Location 12 Figure 3.7 Installing the Avaya P460 Fan Module 13 Figure 3.8 Location of the Avaya P460 Supervisor Modules 14 Figure 3.9 Installing the P460 Supervisor Module 15 Figure 3.10 Lcoation of Avaya P460 I/O Modules 16 Figure 3.11 I/O Module Component Location 17 Figure 3.12 Installing P460 I/O Modules 18 Figure 4.1 Power Allocation after PSU Removal 21 Figure 4.2 Power Management Priority 23 Figure 4.3 I/O Module Power Management Process 24 Figure 5.1 M460ML-SPV LEDs 25 Figure 5.2 M460ML-SPV Function LEDs 28 Figure 5.3 Function LEDs Cycle 28 Figure 5.4 M460ML-SPV Supervisor Module Console Ports 31 Figure 5.5 P460 Supervisor Module Left and Right Pushbutton 31 Figure 5.6 P460 Supervisor Module ASB Pushbutton 32 Figure 7.1 M460ML-SPV Supervisor Module Serial Console Port 41 Figure 7.2 M460ML-SPV Supervisor Module Fast Ethernet Console Port 43 Figure 7.3 Redundant Outband Connections 45 Figure 8.1 The Welcome Page 50 Figure 8.2 P460 Device Manager 51 Figure 9.1 RADIUS Authentication Procedure 58
Avaya P460 Installation and Maintenance Guide vii

viii Avaya P460 Installation and Maintenance Guide
List of Figures

Before you Install the Avaya™ P460
Safety Information
Avaya P460 Installation and Maintenance Guide I

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications to this equipment not expressly approved by Avaya Inc. could void the user’s authority to operate the equipment.
Documentation for this product uses the following conventions to convey instructions and information:
L Text with the L symbol contains helpful information or hints or reference to material in other documentation.
II Avaya P460 Installation and Maintenance Guide
Preface

Avaya Inc. provides a limited warranty on this product. Refer to your sales agreement or other applicable documentation to establish the terms of the limited warranty. In addition, Avaya’s standard warranty language as well as information regarding support for this product, while under warranty, is available through the following website: http://www.support.avaya.com
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change.
Avaya provides a telephone number for you to use to report problems or to ask questions about your contact center. The support telephone number is 1-800-242- 2121 in the United States. For additional support telephone numbers, see the Avaya Web site: http://www.avaya.com
Select Support, then select Escalation Lists. This Web site includes telephone numbers for escalation within the United States. For escalation telephone numbers outside the United States, select Global Escalation List.
Avaya P460 Installation and Maintenance Guide III
Preface

IV Avaya P460 Installation and Maintenance Guide
Preface

Avaya P460 Overview
Introduction
The Avaya™ P460 is a flexible six-slot modular chassis, with two slots reserved for supervisor modules and the four remaining slots for switched I/O modules. It is ideal as a LAN edge and wiring closet switch for SMEs or as an “all-in-one” solution for branch offices. You can also deploy the Avaya P460 in data centers or as a distribution switch.


Chapter 2 Avaya P460 Overview

Avaya P460 Chassis and Module Installation
Introduction
This chapter guides you through the basic hardware Installation process. L If you purchased an Avaya P460ML-CFG (Material code 700255003, PEC Code 4548-009), then one Supervisor Module, PSU and the Fan Module are already installed.

Chapter 3 Avaya P460 Chassis and Module Installation
You require the following equipment in order to install the P460 chassis: • Phillips (cross-blade) screwdriver
Table 3.1 Environmental Requirements
Ambient temperature 23o to 122oF (-5o to 50oC)
Relative humidity 5% to 95%, non condensing
Minimum clearance for ventilation
2" (5 cm) on each side
Weight support 50 lb. (23 kg) to 100 lbs (45 kg)

Chapter 3 Avaya P460 Chassis and Module Installation
Table 3.2 AC Power Requirements
Voltage 100 to 240 VAC, 50/60 Hz
Current for one Avaya MPS4603-AC 300 W PSU
Table 3.3 Dimensions
Height 10U (17.5", 444.5 mm)
Width 17.4" (442 mm)
Depth 15" (375 mm)

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.1 shows the positions of the components in the P460 chassis.
Figure 3.1 The Avaya P460 Switch – Component Location

1 Supervisor modules 2 I/O Modules 3 PSUs 4 Fan module

Chapter 3 Avaya P460 Chassis and Module Installation
Place the system on a surface that supports at least 100 lbs (45 kg). 5 Install the supplied rubber feet to the bottom of the switch, placing the feet in the square recesses provided. See Figure 3.2. Clean the surface of any oils or residue before applying the feet.
Figure 3.2 Table-Top Installation
6 Ensure that all the preinstalled components are firmly installed in the chassis. These include: — Supervisor modules — Power supply — Fan module
You can mount the Avaya P460 in a standard 19" rack either in “front-mount” or “mid-mount” positions with the brackets supplied with the chassis.
The brackets are symmetric: you can fix either bracket one either side.
Rubber feet

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.3 shows the two mounting positions:
Figure 3.3 P460 Front-Mount and Mid-Mount Positions (side view)
a Rack b P460 switch L The chassis height is 10U.

Chapter 3 Avaya P460 Chassis and Module Installation
1 Position the brackets as shown in Figure 3.4
Figure 3.4 Positioning the rack-mounting brackets

a Front-mount position b Mid-mount position
2 Firmly fix the brackets to the chassis with the screws provided. Use five screws for each bracket. 3 Position the switch in the rack. 4 Fasten the switch in the rack with the screws provided. L The screw size is 8-32x¼


Chapter 3 Avaya P460 Chassis and Module Installation
You can use the cable guide to tidy cables from the Supervisor and I/O modules. The cable guide is symmetric: you can install the bracket on either side of the switch. L Avaya recommends that you install the cable guide on the left side of the switch to allow easier access to the fan module. L You need to install the rack mounting brackets before you can install the cable guides. L Install the switch in the rack before installing the cable guide. • Secure the cable guide to the rack mounting bracket using the captive screws on the cable holder (see Figure 3.5).
Figure 3.5 Installing the Cable Guide
Left side of chassis Right side of chassis

a Cable Guide b Rack-mounting bracket

Chapter 3 Avaya P460 Chassis and Module Installation
L If you purchased an Avaya P460ML-CFG (Material code 700255003, PEC Code 4548-009), then one Supervisor Module, PSU and the Fan Module are already installed.
For further information on Power Supply Installation, see Chapter 4, “Turning on the Avaya P460“

Chapter 3 Avaya P460 Chassis and Module Installation
L The P460 Chassis is shipped with a fan module already installed.
Figure 3.6 The Avaya P460 Switch – Fan Module Location

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.7 Installing the Avaya P460 Fan Module
To install a fan module: 1 Remove the existing fan module. a Loosen the fastening screws. b Gently pull the module towards you. 2 Position the module in the slot with the screws to the right side of the chassis (see Figure 3.7). 3 Gently slide the module in. 4 Gently tighten the screws.

Chapter 3 Avaya P460 Chassis and Module Installation
L If you purchased an Avaya P460ML-CFG (Material code 700255003, PEC Code 4548-009), then one Supervisor Module, PSU and the Fan Module are already installed.
Figure 3.8 shows the positions of the SPV Supervisor installed in the P460 chassis.
Figure 3.8 Location of the Avaya P460 Supervisor Modules
L You can install Supervisor modules in the top two slots – 1 and 2 – only.

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.9 Installing the P460 Supervisor Module
a Open locking handle b Closed locking handle
To install a Supervisor module: 1 Remove the blanking plate or installed module as appropriate. 2 Open the locking handles at the edge of the front panel. 3 Position the module in the slot as shown in Figure 3.9. 4 Gently slide the module in. L Ensure the hooks on the locking handle are aligned with the matching holes on the chassis. 5 Close the locking handles. X The module slides back and connects to the backplane. 6 Gently tighten the screws. L For information on configuring redundant supervisor modules, refer to “M460ML-SPV Supervisor Module Redundancy“ on page 35.
a · b

Chapter 3 Avaya P460 Chassis and Module Installation
L If you purchased an Avaya P460ML-CFG (Material code 700255003, PEC Code 4548-009), then one Supervisor Module, PSU and the Fan Module are already installed.
Figure 3.10 shows the positions of I/O modules installed in the P460 chassis.
Figure 3.10 Lcoation of Avaya P460 I/O Modules
L You can install I/O modules in the bottom four slots – 3 to 6 – only.

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.11 I/O Module Component Location

1 Module label 2 Securing screws 3 Locking handles
To install an I/O module: 1 Remove the blanking plate by unscrewing the captive screws and gently pulling the plate towards you. 2 Open the locking handles at the edge of the front panel. See Figure 3.12. 3 Position the module as shown in Figure 3.12. 4 Gently slide the module in. L Ensure the hooks on the locking handle are aligned with the matching holes on the chassis. 5 Close the locking handles. X The module slides back and connects to the backplane. 6 Gently tighten the screws. L For module-specific information, refer to the Installation Guide shipped with the module.

Chapter 3 Avaya P460 Chassis and Module Installation
Figure 3.12 Installing P460 I/O Modules
a Open locking handle b Closed locking handle

Turning on the Avaya P460
Introduction
Once you have installed the Avaya P460 chassis and modules, you can turn the chassis on. The Avaya P460 chassis can accommodate one, two or three PSUs (Power Supply Units). The available power is divided among the modules by the Supervisor Module. See “Power Management“ on page 23 further information.
L Use the handle on the front panel of the PSU to lift it. L You can install the PSU in any of the three slots. 1 Remove the blanking plate by unscrewing the four retaining screws and gently tugging the plate towards you. 2 Position the PSU with the label facing up and to the right. 3 Gently slide the PSU back until the socket on the back of the PSU engages in the plug on the chassis. L Ensure the guiding pins on the front panel of the PSU align with the holes on the front panel of the P460 chassis. 4 Gently tighten the screws on the PSU.

Chapter 4 Turning on the Avaya P460
In order to turn on the chassis you need to install at least one PSU and at least one Supervisor Module. L The fans are on whenever the power is on in the chassis, whether Supervisor Modules are installed or not.
If you have inserted Supervisor module(s) and I/O module(s) into the chassis before turning on the PSUs, the power-up procedure is as follows: 1 The Supervisor module(s) and fans are turned on automatically when the PSUs are turned on. 2 The Supervisor module will turn on the modules one by one, verifying that there is enough power budget in the system first. If there are two Supervisor modules, the Active Supervisor Module perfoms this procedure.
L The fans are on whenever the power is on in the chassis, whether Supervisor Modules are installed or not.
If you turn on the PSU(s) in a chassis with a Supervisor Module, the power-up procedure is as follows: 1 The fans start. 2 The supervisor module is turned on. X You can now insert I/O Modules
If you turn on the PSU(s) in an empty chassis – no Supervisor modules – the fans will start up.
1 The SPV adds the new PSU power budget and checks how many PSUs are present in the chassis 2 Modules not powered up because of an insufficient power budget are turned on. Otherwise the new PSU power is just added to the total available power. 3 The PSU you insert are in redundant mode if the existing PSUs can already provide enough power for the chassis and installed components.

Chapter 4 Turning on the Avaya P460
The entire chassis turns off
1 When you remove a PSU from the chassis, the Supervisor Module recalculates the power budget. If the power requirement exceeds the capacity of one PSU, the I/O modules are then turned on according to the power budgeting scheme described below. See Figure 4.1. a The chassis is automatically turned on with only the Supervisor Modules and the fans getting power from the available PSU b If all the available I/O modules were operational before the PSU removal/ failure, the Supervisor Module starts to apply power. The power is first applied to as many I/O modules as possible within the power budget limit of the single PSU. This can mean that an I/O module with a low power requirement and low priority is powered up rather than a high power requirement module with a higher priority. c Slots whose power is disabled are skipped.
Figure 4.1 Power Allocation after PSU Removal
Apply power to slot 5
Apply power to slot 3
Apply power to slot 6
Apply power to slot 4

Chapter 4 Turning on the Avaya P460
The chassis continues to run: two PSUs are sufficient to supply power to a fully populated chassis.

Chapter 4 Turning on the Avaya P460
The Supervisor module checks the PSU status every three seconds by comparing the current state to the previously saved PSU state.
Figure 4.2 Power Management Priority


Chapter 4 Turning on the Avaya P460
Figure 4.3 I/O Module Power Management Process
Apply power to slot 5
Apply power to slot 3
Apply power to slot 6
Apply power to slot 4

Avaya P460 Panels
Introduction
This chapter describes the front panels of the P460 switch modules, including the LEDs, ports and buttons.
M460ML-SPV modules can operate in three modes: Active, Standby and Halted. Each mode is reflected in the LEDs – further details are provided in Table 5.1.
Figure 5.1 M460ML-SPV LEDs

Table 5.1 summarizes the functions of the LEDs for an active M460ML-SPV supervisor module.
Table 5.1 Active M460ML-SPV LEDs
LED Description State Meaning
ACT Active SPV indication ON
ROUT Device switching mode ON Layer 3
OPR CPU operation System status
ON CPU boot and BIT (built-in test) completed
Blinking CPU booting or running BIT Fan module not installed.
OFF CPU cannot boot (see Chapter 12, "Troubleshooting the Installation")
OFF Layer 2

Chapter 5 Avaya P460 Panels
Table 5.1 Active M460ML-SPV LEDs
LED Description State Meaning
PWR Power information ON Power is up
OFF Power is off
Table 5.2 Active M460ML-SPV FastETH LED
LED Description State Meaning
Management outband Ethernet link status
ON Port enabled and link OK No data transmitted or received on the port
Blinking Port enabled and link OK Data transmitted or received on the port
OFF Link is not operating
Table 5.3 summarizes the functions of the LEDs for a standby or halted M460ML-SPV supervisor module.
Table 5.3 Standby/Halted M460ML-SPV LEDs
LED Description State Meaning
ACT Active SPV indication OFF
ROUT Device switching mode OFF
OPR CPU operation ON CPU boot and BIT completed Module in Standby mode
Blinking Module in Halted mode or CPU and BIT not completed
PWR Power information ON Power is up
OFF Power is off
Fast ETH

Chapter 5 Avaya P460 Panels
Table 5.3 Standby/Halted M460ML-SPV LEDs
LED Description State Meaning
Management outband Ethernet link status
Table 5.4 Standby M460ML-SPV FastETH LED
LED Description State Meaning
Management outband Ethernet link status
ON Port enabled and link OK No data transmitted or received on the port
Blinking Port enabled and link OK Data transmitted or received on the port
OFF Link is not operating
Table 5.5 summarizes the states of the ACT and OPR LEDs
Table 5.5 ACT and OPR LED Summary
ACT LED is... OPR LED is... M460ML-SPV Module is...
ON Blinking Active Fan Module not inserted
OFF Blinking Halted or booting Fan Module not inserted

Chapter 5 Avaya P460 Panels
Figure 5.2 M460ML-SPV Function LEDs
Use the L (Left) and R (Right) pushbuttons to select the information displayed for all the port LEDs on the installed I/O modules. Press the button to cycle through the options: the illuminated LED shows the option. See “M460ML-SPV Left and Right Pushbuttons“ on page 31 for further information on the pushbuttons.
Figure 5.3 shows the cycle.
Figure 5.3 Function LEDs Cycle
COL
LAG
FDX FC

Chapter 5 Avaya P460 Panels
Table 5.6 summarizes the meanings of the function LEDs. Certain indications depend on the specific I/O module port type:
Table 5.6 M460ML-SPV Function LEDs
LED Description State Meaning
LNK Port status ON Port enabled and link OK
OFF Port disabled or link is not operating
COL Collision detection ON Collision occurred on line
OFF No collision or FDX port
Tx Transmit to line ON Data transmitted to the line
OFF No transmit activity
Rx Receive from line ON Data received from the line
OFF No receive activity
ON Full-duplex mode For 10/100BASE-T ports when the link test fails with auto- negotiation enabled
FC Flow Control ON Flow Control is active
OFF Flow Control is disabled
HSpd Port speed indication ON Port 10/100 1000 100 Mbps 1000 Mbps
OFF Port 10/100 1000 10 Mbps N/A
FDX Full-/Half-duplex Indication · OFF Half-duplex mode

Chapter 5 Avaya P460 Panels
Table 5.6 M460ML-SPV Function LEDs
LED Description State Meaning
LAG Link Aggregation Group
ON Port is a member of a LAG
OFF Port is not a member of a LAG
PoE* Power over Ethernet ON PoE is enabled and power is being supplied to an end- station
OFF PoE disabled for this port
*Not currently implemented

Chapter 5 Avaya P460 Panels
Figure 5.4 M460ML-SPV Supervisor Module Console Ports
1 Eth (Ethernet) Port 2 RS-232 (Serial) port
A 10/100BASE-T port with an RJ-45 connector for managing the P460 by a dedicated LAN.
An RJ-45 RS-232 serial port for connecting a modem or terminal for configuration with the CLI.
Figure 5.5 P460 Supervisor Module Left and Right Pushbutton
1 L (Left) pushbutton 2 R (Right) pushbutton
Table 5.7 M460ML-SPV Left and Right Pushbutton Functions
To... Press...
Cycle between the Function LEDs. See “Function LEDs“ on page 28 for further information
The Left or Right button briefly.
Reset the Supervisor Module Both buttons at the same time for 1.5 seconds.
Reset the chassis Both buttons at the same time for five seconds.

Chapter 5 Avaya P460 Panels
Figure 5.6 P460 Supervisor Module ASB Pushbutton
L See “Supervisor Module does not Boot“ in “Troubleshooting the Installation“ for information.

Chapter 5 Avaya P460 Panels
P460 Power Supply Front Panel

1 Status LED 2 Power inlet 3 Power switch
Table 5.8 Power Supply Status LED
LED Description State Meaning
Power Supply Status Green Power supply functioning
Orange Power supply failure Power supply off

Chapter 5 Avaya P460 Panels

Maximizing Avaya P460 Availability
Introduction
In order to maximize availability of the Avaya P460 for applications such as VoIP, you can deploy a variety of redundancy mechanisms.
This chapter describes the Supervisor module and I/O module redundancy and power supply availability features.
To enable supervisor redundancy, you need to install two M460ML-SPV Supervisor Modules in a P460 Chassis. Ensure that one Supervisor module is “Active” and that the second is “Standby”.
Table 6.1 ACT and OPR LED Summary
ACT LED is... OPR LED is... M460ML-SPV Module mode
ON Blinking Active No fan module present
OFF Blinking Halted or booting
ON ON Active · OFF ON Standby

Chapter 6 Maximizing Avaya P460 Availability
If the SPVs are not synchronized, you need to synchronize them manually using the Avaya P460 CLI.
1 Access the CLI. See Chapter 7, “Establishing Switch Access“ 2 Enter the sync spv command from the Active Supervisor Module. L This command transfers the following information from the Active Supervisor module to the other Supervisor module: — Firmware images — Embedded Web image — Preferred boot bank — Chassis synchronization L The transfer process can take up to 90 seconds.

Chapter 6 Maximizing Avaya P460 Availability
L The following screen capture shows the process:
P460-1(super)# sync spv This command may overwrite the neighbor SPV software and reset both SPVs *** Confirmation *** - do you want to continue (Y/N)? y Copying Bank A to the neighbor SPV ... Copying Bank A to the neighbor SPV done Copying Bank B to the neighbor SPV ... Copying Bank B to the neighbor SPV done Copying Embedded Web image to the neighbor SPV ... Copying Embedded Web image to the neighbor SPV done Setting boot bank of the neighbor SPV ... Setting boot bank of the neighbor SPV done Setting chassis sync on for the neighbor SPV... Setting chassis sync on for the neighbor SPV done SPVs are resetting. Please wait till the process is finished. The SPVs will be synchronized after the reset is completed
— After the reset the configuration files of the Active Supervisor Module are copied to the Standby Supervisor Module. L This process can take up to two minutes.

Chapter 6 Maximizing Avaya P460 Availability

Chapter 6 Maximizing Avaya P460 Availability
The Avaya P460 supports automatic Power Supply redundancy and load-sharing.
Power supply redundancy is activated according to the number of PSUs and I/O modules you have installed in the chassis.
Three PSUs are automatically configured in 2+1 redundancy mode.
If the installed power supplies can provide sufficient power for the switch, then an additional power supply is automatically configured to operate in Redundancy mode.
If the power budget requirement increases beyond the power available from the non-redundant power supplies, then the additional power supply reverts to regular mode.
In order to check whether power supply redundancy is operating, you can use the show environment power CLI command.
P460 > show environment power PSU1 Capacity: 300 Watts (48V @ 6.25 Amps) PSU2 Capacity: none PSU3 Capacity: none
PSUs Configuration: 1 PSU/s , no redundancy. Total Power Available: 300 Watts (6.25 Amps @ 48V) Total Power drawn from the system: 229 Watts (4.77 Amps @ 48V) Remaining Power in the system: 71 Watts (1.48 Amps @ 48V)
Slot Card-Type Active Enabled Draws(W) Fault
4 avayaP460-M4648ML-T Y Y 48
6 N Y 0

Chapter 6 Maximizing Avaya P460 Availability
You can also calculate how many PSUs you need in order to provide redundancy for a specific configuration.
You need to add the power requirements for the I/O modules installed to the base requirement of two Supervisor modules and one Fan module. If the total is less than the power supplied by the number of PSUs installed, an additional PSU provides redundancy.
Table 6.2 shows a sample calculation:
Table 6.2 Sample Power Budget Calculation
2 x M460ML-SPV Supervisor Modules 136
2 x M4648ML-T I/O Modules 96
An additional power supply will operate in redundant mode. L Refer to “Power Requirements” on page 80 for power requirements for P460 components.
Component Requirement (W) · Fan module 45 · Total 277

Establishing Switch Access
Introduction
Figure 7.1 M460ML-SPV Supervisor Module Serial Console Port
Perform the following steps to connect a terminal to the P460 Serial Console port for configuration of switch parameters: 1 Use the serial cable supplied to attach the RJ-45 console connector to the Console port of the active M460ML-SPV module. Connect the DB-9 connector to the serial (COM) port on your PC/terminal. L The active Supervisor module is indicated by the ACT and OPR LEDs being lit. 2 Ensure that the serial port settings on the terminal are: — 9600 baud — 8 bits — 1 stop bit — no parity. X If you reset or powered up the switch after connecting and configuring the terminal, Welcome to P460 appears followed by the Login Name prompt. L If the login prompt does not appear, press a key on the terminal. 3 Enter the default login: root. X The Password prompt appears 4 Enter the user level password: root.

Chapter 7 Establishing Switch Access
Perform the following steps to establish a Telnet connection to the P460 for configuration: L You need to assign an inband interface IP address using a direct connection to the console serial port before you can establish the Telnet session. 1 Connect your station to the I/O module (directly or via the network). 2 Verify that you can communicate with the P460 using Ping to the inband interface IP of the P460. If there is no response using the Ping command, check the IP address and default gateway of both the P460 and the station. L The default subnet mask is 255.255.255.0. 3 Start a Telnet session:
— From the Microsoft Windows® taskbar of your PC click Start and then Run or access the command prompt — Start the Telnet session by typing: telnet <P460_IP_address> For example: telnet 149.49.35.214 X The Login Name prompt is displayed 4 Enter the default name root X The password prompt is displayed 5 Enter the password root in lower case letters. L You can now configure the P460.
In order to... Use the following command...
Configure the management interface
Configure the management VLAN ID
Enable the inband interface enable interface inband
Disable the inband interface disable interface inband
set interface inband · set inband vlan

Chapter 7 Establishing Switch Access
In order to... Use the following command...
Display information on the device network interfaces
Send an ICMP echo request packets to another node on the network.
Figure 7.2 M460ML-SPV Supervisor Module Fast Ethernet Console Port
Perform the following steps to establish a Telnet connection to the P460 for configuration: L You need to assign an outband interface IP address using a direct connection to the console serial port before you can establish the Telnet session. L You can configure the Fast Ethernet console port parameters if necessary. L The outband interface should be on a different subnet from the inband interface. 1 Connect your station to the Fast Ethernet console port (directly or via the network). 2 Verify that you can communicate with the P460 using “ping” to the outband interface IP of the P460. If there is no response using the Ping command, check the IP address and default gateway of both the P460 and the station. 3 Start a Telnet session:
— From the Microsoft Windows® taskbar of your PC click Start and then Run or access the command prompt — Start the Telnet session by typing: telnet <P460_IP_address> For example: telnet 149.49.35.214 X The Login Name prompt is displayed 4 Enter the default name root X The password prompt is displayed 5 Enter the password root in lower case letters.
show interface · ping

Chapter 7 Establishing Switch Access
L You can now configure the P460. L You can connect the Out-band interface to either of the Supervisor modules.
In order to... Use the following command...
Configure the management interface
Enable the outband interface enable interface outband
Disable the outband interface disable interface outband
Enable or disable the link negotiation protocol on the Fast Ethernet console port
Set the speed of Fast Ethernet Console port
Set the duplex mode of the Ethernet Console port
Display information on the device network interfaces
Display outband interface parameters
Send an ICMP echo request packets to another node on the network.

Chapter 7 Establishing Switch Access
You can create a redundant outband management connection by connecting both Supervisor modules to the NMS via the Fast Ethernet interface by a switch (see Figure 7.3).
Figure 7.3 Redundant Outband Connections

In this configuration, the Active SPV will respond to its Out-band port and the port of the other SPV will be ignored.
Switch · Workstation

Chapter 7 Establishing Switch Access
The Point-to-Point Protocol (PPP) provides a Layer 2 method for transporting multi- protocol datagrams over point-to-point links. Here only IP datagrams will be exchanged, over a RS232 serial connection, between the P460 supervisor module and a remote peer (such as Ethernet) via a modem and the telephone lines. This provides remote access the sideband management interface of a P460 via a modem.
In order to... Use the following command...
Configure the device ppp interface and control a PPP session
Configure the shared secret used in PPP sessions with CHAP authentication
Set the time after which the system automatically disconnects an idle PPP incoming session
set ppp incoming timeout
Define the PPP authentication method
set ppp authentication incoming
Set the baud rate used in PPP sessions
Display the PPP parameters of the active PPP session.
Display the authentication method used for PPP sessions
Display the time after which the system automatically disconnects an idle PPP incoming session
show ppp incoming timeout
Display the baud rate used in PPP sessions
Display the ppp configuration show ppp configuration

Chapter 7 Establishing Switch Access
L You need to configure an IP address and netmask for the sideband interface before you can establish a ppp link. 1 Connect a terminal to the Serial console port. 2 When you are prompted for a Login Name, enter the default name root. 3 When you are prompted for a password, enter the password root. You are now in Supervisor Level. 4 At the prompt, type: set interface ppp <ip_addr> with an IP address and netmask to be used by the Avaya P460 Supervisor module to connect via its PPP interface. L The PPP interface you configure with the set interface ppp command must be on a different subnet from the inband and outband interfaces. 5 Set the baud rate, ppp authentication, and ppp time out required to match your modem. 6 At the prompt, type: set interface ppp enable X The following is displayed: Entering the Modem mode within 60 seconds... Please check that the proprietary modem cable is plugged into the console port 7 Use the DB-25 to RJ-45 connector to plug the console cable to the modem’s DB- 25 connector. Plug the other end of the cable RJ-45 connector to an Avaya P460 Supervisor module RJ-45 port. 8 The Avaya P460 Supervisor module enters modem mode. 9 You can now dial into the switch from a remote station, and open a Telnet, ping or SNMP management session to the PPP interface IP address. L If you have two Supervisor modules installed, you can make a serial connection to one SPV and configure the PPP parameters through one session and deploy the PPP connection on the second Supervisor module.

Chapter 7 Establishing Switch Access

Avaya MSNM P460 Manager

Chapter 8 Avaya MSNM P460 Manager
1 Open your browser. 2 Enter the URL of the switch in the format http://aaa.bbb.ccc.ddd where aaa.bbb.ccc.ddd is the inband or outband interface IP address of the switch.
X The welcome page is displayed.
Figure 8.1 The Welcome Page


Chapter 8 Avaya MSNM P460 Manager
X If you have the Java plug-in installed, the P460 Manager should open in a new window (see Figure 8.2)
Figure 8.2 P460 Device Manager

— If you do not have the Java plug-in installed, follow the instructions on the Welcome page that offers a variety of options to install the plug-in. L You cannot configure Layer 3 parameters if you run the P460 Device Manager over the Outband interface.

Chapter 8 Avaya MSNM P460 Manager
If the network manager has configured the system, the plug-in should be installed automatically.
If the plug-in is not installed automatically, then you have three options for installing it manually:
1 Installing from the P460 Documentation and Utilities CD 1 Close all unnecessary applications on your PC. 2 Insert the “Avaya P460 Documentation and Utilities” CD in the CD drive. 3 Open Windows® Explorer. 4 Open the embweb-aux-files\ folder on the CD 5 Double click on the plugin_a_b_c.exe file (a, b and c are the version numbers of the plug-in). 6 Follow the on-screen instructions.
Click on the link in the Welcome page.
Click on the link in the Welcome page.

Chapter 8 Avaya MSNM P460 Manager
Copying the help files and Java plug-in to a local Web server allows users to access the on-line help for the Embedded Manager and enables automatic Installation and Maintenance of the Java plug-in the first time the users tries to manage the device. 1 Copy the emweb-aux-files directory from the “Avaya P460 Documentation and Utilities” CD to your local Web server. Please refer to your Web server documentation for full instructions. 2 Define the URL in the P460 using the following CLI command: set web aux-files-url //IP address/directory name where //IP address/directory name is the location of the directory from the previous step.
The Device Manager comes with a detailed User’s Guide including a Glossary of Terms and an overview of Data Communications concepts.

Chapter 8 Avaya MSNM P460 Manager

User Authentication
Introduction
User Authentication is an important element of maintaining secure networks. It prevents unauthorized network management and stops users from reconfiguring network devices.
The Local User Account feature allows you to define up to ten accounts that can manage a local (single) P460 switch. This simplifies administration on small networks or where users do not log in to more than one switch.
You need to define a user name, password and access level for each user.
In addition to the user name and password, you need to assign an access level for each user. There are three access levels, each of which allows the user only to perform certain actions. Refer to Table 9.1 for a brief description of each level.
Table 9.1 Access Level Descriptions
Level Suitable for... Allows...
Read-only General users Viewing of system parameter values.
Read-write Site personnel Access to configuration options.
As “read-write” plus configuring Local User accounts and access to RADIUS authentication configuration commands
Administrator Network administrator

Chapter 9 User Authentication
In order to... Use the following command...
Add a local user account and configure a user (name, password and access level)
To remove a local user account no username
Display the username, password and access type for all users on the switch
username · show username

Chapter 9 User Authentication
Local user accounts (see “Local User Accounts“ on page 55) are kept locally on the switch. Therefore, if a site contains multiple Avaya Switches, it is necessary to configure each switch with its own user accounts. Additionally, if for example a 'read-write' user has to be changed into a 'read-only' user, it will be necessary to change all the 'read-write' passwords configured locally in every switch, in order to prevent him to access this level anymore. This can be tedious at best, and at worst, unmanageable. A better solution is to have all of the user login information kept in a central location where all the switches can access it. Enter Remote Authentication Dial-In User Service (RADIUS).
RADIUS (Remote Authentication Dial-In User Service) provides a mechanism for such consolidation. A RADIUS authentication server is installed on a central computer at the customer's site. On this server user authentication (account) information is configured that provides various degrees of access to the switch. The P460 will run as a RADIUS client. When a user attempts to log into the switch, if there is no local user account for the entered user name and password, then the switch will send an Authentication Request to the RADIUS server in an attempt to authenticate the user remotely. If the user name and password are authenticated, then the RADIUS server responds to the switch with an Authentication Acknowledgement that includes information on the user's privileges ('administrator', 'read-write', or 'read-only'), and the user is allowed to gain access to the switch. If the user is not authenticated, then an Authentication Reject is sent to the switch and the user is not allowed access to the switch's embedded management.

Chapter 9 User Authentication
Figure 9.1 illustrates the RADIUS authentication procedure:
Figure 9.1 RADIUS Authentication Procedure
Yes Authentication request sent to RADIUS Server
sent to switch User cannot access switch
to user's priviliege level
In order to... Use the following command...
Enable or disable authentication for the P460 switch. RADIUS authentication is disabled by default
Set a primary or secondary RADIUS server IP address
set radius authentication server
Configure a character string to be used as a “shared secret” between the switch and the RADIUS server.
set radius authentication secret

Chapter 9 User Authentication
In order to... Use the following command...
Set the RFC 2138 approved UDP port number.
set radius authentication udp-port
Set the number of times an access request is sent when there is no response
set radius authentication retry- number
Set the time to wait before re- sending an access request.
set radius authentication retry-time
Remove a primary or secondary RADIUS authentication server
clear radius authentication server
Display all RADIUS authentication configurations. The shared secrets will not be displayed
show radius authentication

Chapter 9 User Authentication
With the Allowed Managers feature, the network manager can determine who may or may not gain management access to the switch. The feature can be enabled or disabled (default is disabled). When enabled, only those users that are configured in the Allowed Managers table are able to gain Telnet, HTTP, and SNMP management access to the switch.
You can configure up to 20 Allowed Mangers by adding or removing their IP address from the Allowed Managers List.
In order to... Use the following command...
When set to enabled - only managers with ip address specified in the allowed table will be able to access the device
Add/delete ip address of manager to/from the allowed table
set allowed managers ip
Show the IP addresses of the managers that are allowed to access the device
show allowed managers table
Show whether the status of allowed managers is enabled or disabled
show allowed managers status
Show the IP addresses of the managers that are currently connected
set allowed managers · show secure current

Configuration Defaults
Introduction
This chapter defines the default parameters for the P460 switch.
Table 10.1 Default System Parameters
All IP addresses N/A (0.0.0.0)
Default gateway N/A (0.0.0.0)
CLI timeout 15 minutes
In-band ARP Tx interval 5 seconds
Out-of-band ARP Tx interval 5 seconds
VLANs 1 on all ports
Bridge priority for Spanning Tree 32,768
NTP server IP address N/A
Time zone offset 0 hours
Read-only SNMP community string public

Chapter 10 Configuration Defaults
Table 10.1 Default System Parameters
Read-write SNMP community string public
Trap SNMP community string public
Number of SNMP retries 3
Broadcast storm control Disabled
In order to... Use the following command...
Restore all parameters to the default values

Basic Switch Configuration
Introduction
This chapter describes the parameters you can define for the chassis, such as its name and location, time parameters, and so on.
Use the CLI commands briefly described below for configuring the display on your terminal or workstation.
In order to... Use the following command...
Open a CLI session to the alternative SPV in the P460 chassis
Display or set the terminal width (in characters)
Display or set the terminal length (in lines)
Display or set the prompt hostname
Return the prompt to its default value
Clear the current terminal display clear screen
Set the number of minutes before an inactive CLI session automatically logs out
Display the number of minutes before an inactive CLI session automatically times out
Access Layer 3 configuration if not logged in as supervisor (see “Access Levels“ on page 55)
Enter tech mode L This command is reserved for service personnel only

Chapter 11 Basic Switch Configuration
In order to... Use the following command...
Display the commands available at your current location in the CLI hierarchy
In order to make a P460 switch easier to identify, you can define a name for the switch, contact information for the switch technician and the location of the switch in the organization.
In order to... Use the following command...
Configure the system name. set system name
Configure the system contact person
Configure the system location set system location
You can use the following commands to configure and display the mode of operation for the switch and display key parameters.
In order to... Use the following command...
Configure the basic mode of operation to either Layer 2 or Routing
Display the mode of operation show device-mode
Display system parameters show system
Display module parameters show module
tree · set system contact · set device-mode

Chapter 11 Basic Switch Configuration
In order to... Use the following command...
Restore the time zone to its default, UTC.
Configure the time zone for the system
Configure the time protocol for use in the system
Enable or disable the time client set time client
Configure the NTP server address set time server
Display the current time show time
Display the time status and parameters
Display the current time zone offset show timezone
Get the time from the time server get time
Certain features in the Avaya P460 are activated by “Feature Licenses.” A sample activation procedure for these features is described below:
In order to benefit from the P460 routing capabilities, you need to purchase an Avaya L480L3-License Routing License Key Certificate (catalog number 700255060) for each P460 chassis .
After you purchase a Feature Licence Key Certificate, you must obtain and activate a Feature License Key.

Chapter 11 Basic Switch Configuration
To obtain a License Key that enables routing features:
1 Go to http://license-lsg.avaya.com and click “request new license”.

2 Enter the Certificate Key and Certificate Type.

3 Click Next. 4 Enter contact information (once per certificate)

5 Click Next.

Chapter 11 Basic Switch Configuration
X View number of licenses left.

6 Enter the serial number of the switch. To identify serial numbers use the show chassis-identity CLI command: .

7 Click Generate. X The feature-enabling license code is generated


Chapter 11 Basic Switch Configuration
To activate a Routing License Key:
1 Enter the acquired Routing License Key into the M460ML-SPV module using the set license CLI command. set license [license] [featureName]
where:
license - license code
and press Enter. 2 Check that the license is activated using the CLI. Use the show license CLI command.
In order to... Use the following command...
Configure the feature license set license
Display the feature license show license
Display the switch identity required for acquiring a license
featureName - routing · show chassis-identity

Troubleshooting the Installation
Introduction
Problem Possible Cause Solution
Chassis does not power up
No PSU (Power Supply Unit) installed
Install PSU (see “PSU (Power Supply Unit) Installation“ on page 11)
PSU not connected to power source
Connect PSU to the power source
PSU not turned on Turn on the PSU using the power switch on the PSU front panel
Problem Possible Cause Solution
Supervisor modules do not power up
Supervisor module not installed correctly
Ensure that the module is installed correctly.
Problem Possible Cause Solution
Fans do not start Chassis not powered up
See “Chassis does not power up“ on page 69
Fan module not installed correctly
Check that Fan module is installed correctly

Chapter 12 Troubleshooting the Installation
Problem Possible Cause Solution
I/O modules do not power up
No Supervisor module installed
Install supervisor module (see “Supervisor Module Installation“ on page 14)
Supervisor module not functioning
Remove un-needed I/O modules or Disable power to the appropriate I/O slots. See the set slot power command
Rearrange I/O Modules to reflect priority
Power disabled to I/O slot
Enable power to slot. See the set slot power command.
I/O modules powered down automatically
Fan module removed for more than five minutes
Re-insert fan module Power down chassis Power up chassis
Replace supervisor module · Insufficient Power Budget · Add PSUs

Chapter 12 Troubleshooting the Installation
Problem Possible Cause Solution
OPR LED does not light.
Supervisor Module has not booted.

Chapter 12 Troubleshooting the Installation

Maintenance
Introduction
This chapter provides some basic information for downloading firmware to the Avaya P460. For issues that are not covered in “Troubleshooting the Installation“ or this chapter, please contact your Avaya representative.
See “I/O Module Installation” on page 16.
When you remove the Supervisor module, the switch is turned off. The switch is turned on after you insert a replacement Supervisor module.
If you remove the Active Supervisor module, the
Configuring the Supervisor Modules for Active/Standby Operation

You can perform software download using the copy tftp command (see page 26 of the Avaya P460 Reference Guide) or the Avaya Software Update Manager (part of the Avaya™ Multiservice Network Manager Suite). L You can obtain the latest firmware from the Avaya support site at http://www.support.avaya.com
Each P460 Supervisor module has two firmware image banks (“A” and “B”) and one Device Manager (Embedded Web) bank.
The download is on a per-chassis basis and the firmware is automatically loaded into the standby Supervisor module (if configured) in addition to the active Supervisor module. L Firmware is not downloaded to a halted Supervisor module.
You download the firmware to each bank separately via the CLI. The download progress is shown on the screen.
You can choose which firmware bank to boot from (preferred bank) using the set boot bank command. L Changing the preferred bank affects both SPVs.
Booting from the Alternate Firmware Bank
Push the ASB button together with both function switches on the SPV front panel to boot from the alternate SW bank. L If the SPVs were running in a Active-Standby configuration and ASB caused SW incompatibility between the SPVs, the Standby SPV will switch to Halted mode.
Chapter 13 Maintenance

In order to... Use the following command...
Set the default boot bank set boot bank
Download firmware to Bank A copy tftp SW_imageA
Download firmware to Bank B copy tftp SW_imageB
Copy Device Manager (Embedded Web) firmware
Show the default boot bank show boot bank
You can transfer the Layer 2 parameters to or from the current NVRAM running configuration file to a TFTP server.
This feature permits you to make a backup of the parameters. You can then use that file to configure other Avaya P460 switches without re-entering all the parameters manually. L To use this feature, you need to have an active tftp server, and to create a file into which to download the data. If Avaya MultiService Network Manager is running, you do not require an additional TFTP server.
In order to... Use the following command...
Upload the Layer 2 parameters from the current NVRAM running configuration to a file via TFTP
Update the Layer 2 parameters in the current NVRAM running configuration from a file via TFTP
Show the Layer 2 configuration file show l2-config

Chapter 13 Maintenance

Standards
Introduction
The Avaya P460 complies with the following standards:

78 Avaya P460 Installation Guide
Chapter 14 Standards

Specifications
Physical
Height 10U (17.5", 444.5 mm)
Width 17.4" (442 mm)
Depth 15" (375 mm)
Chassis + backplane 13 kg (28.6 lb.)
Fan module 2.3 kg (5.1 lb.)
Supervisor module 2.0 kg (4.4 lb.)
300W AC PSU 3.85 kg (8.5 lb.)
PSU blanking panel 0.3 kg (0.7 lb.)
22 kg (48 lb.)
at least 45 kg. (100 lb.)
Weight

Input voltage 100 to 240 VAC, 50 or 60 Hz
Power dissipation 300 W max
Input current 3.9 A at 100 VAC 1.5 A at 240 VAC
Inrush current 15 A at 100 VAC (max.) 30 A at 240 VAC (max.)
Fan Module 45 W
Avaya M4648ML-T 48 W
Avaya M4648ML-T-2G 70 W
Avaya M4612ML-G 59 W
Operating Temp. 23 to 122°F (-5 to 50°C)
Rel. Humidity 5% to 95% non-condensing
Chapter 15 Specifications · MPS4603-AC Power Supply · Components

device with a 16A rating must be incorporated in series with building Installation and Maintenance AC power wiring for the equipment under protection.
Chapter 15 Specifications

Table 15.1 Avaya P460 Catalog Numbers
Product Description Material Code
Avaya P460-CH P460 chassis 7000254998 4548-001
Avaya M460ML-SPV P460 supervisor module 700255011 4548-002
Avaya M4648ML-T P460 Multilayer 48 x 10/ 100BASE-T (RJ-45) module 700255029 4548-003
Avaya M4648ML-T-2G P460 Multilayer 48 x 10/ 100BASE-T (RJ-45) + 2 x GBIC (SFP) module
Avaya M4612ML-G P460 Multilayer 12 x GBIC (SFP) module
Avaya M460-FAN P460 fan module 700255052 4548-006
Avaya L480L3-License P460 Layer 3 license 700255060 4548-007
Avaya MPS4603-AC P460 330W AC PSU 700255078 4548-008
Avaya P460ML-CFG P460 switch basic configuration (SPV, PSU, fan)
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Chassis does not power up | No PSU (Power Supply Unit) installed | Install PSU (see “PSU (Power Supply Unit) Installation“ on page 11) | p.83 |
| Chassis does not power up | PSU not connected to power source | Connect PSU to the power source | p.83 |
| Chassis does not power up | PSU not turned on | Turn on the PSU using the power switch on the PSU front panel | p.83 |
| Supervisor modules do not power up | Supervisor module not installed correctly | Ensure that the module is installed correctly. | p.83 |
| Fans do not start | Chassis not powered up | See “Chassis does not power up“ on page 69 | p.83 |
| Fans do not start | Fan module not installed correctly | Check that Fan module is installed correctly | p.83 |
| I/O modules do not power up | No Supervisor module installed | Install supervisor module (see “Supervisor Module Installation“ on page 14) | p.84 |
| I/O modules do not power up | Supervisor module not functioning | Replace supervisor module | p.84 |
| I/O modules do not power up | Insufficient Power Budget | Add PSUs | p.84 |
| I/O modules do not power up | Remove un-needed I/O modules or Disable power to the appropriate I/O slots. See the set slot power command | p.84 | |
| I/O modules do not power up | Rearrange I/O Modules to reflect priority | p.84 | |
| I/O modules do not power up | Power disabled to I/O slot | Enable power to slot. See the set slot power command. | p.84 |
| I/O modules powered down automatically | Fan module removed for more than five minutes | Re-insert fan module Power down chassis Power up chassis | p.84 |
| OPR LED does not light. | Supervisor Module has not booted. | Use the “ASB” (Alternate Software Bank) button to switch to the second firmware bank. • Press and hold the “L” and “R” buttons to reset the switch. X The switch will reset. • Immediately press the ASB button by gently inserting a small object such as a bent paper clip into the hole. • Keep the ASB button pressed until the reset procedure has completed. If a second software version is present, the SPV modules will then boot from the alternate software image bank. | p.85 |