EN
Casio logo
Official user manual

Casio CFX-9970G

22 pages·102 KB·Calculator·PDF·ENDEFRITNLJA
Casio CFX-9970G
Table of Contents 39 sections 1 Chapter · Basic Operation · k Setting the Angle Unit (Angle) · k Setting the Display Format (Display) · … ShowHide
Page 1 of the Casio CFX-9970G user manual — 1 Chapter
Page 1 · click to enlarge
Page 1

1 Chapter

Basic Operation

1-1 Before Starting Calculations... 1-2 Memory 1-3 Option (OPTN) Menu 1-4 Variable Data (VARS) Menu 1-5 Program (PRGM) Menu

Page 2 of the Casio CFX-9970G user manual — k Setting the Display Format (Display)
Page 2 · click to enlarge
Page 2

Before performing a calculation for the first time, you should use the set up screen to specify the angle unit and display format.

k Setting the Angle Unit (Angle)

1. Display the set up screen and use the f and c keys to highlight “Angle”.
2. Press the function key for the angle unit you want to specify.
  • { Deg } / { Rad } / { Gra } ... {degrees}/{radians}/{grads}
3. Press J to return to the screen that was on the display when you started the procedure.
  • The relationship between degrees, grads, and radians is shown below.

360° = 2π radians = 400 grads

90° = π/2 radians = 100 grads

k Setting the Display Format (Display)

1. Display the set up screen and use the f and c keys to highlight “Display”.
2. Press the function key for the item you want to set.
  • { Fix } / { Sci } / { Norm } / { Eng } ... {fixed number of decimal places specification}/ {number of significant digits specification}/{exponential format display range toggle}/{Engineering Mode}
3. Press J to return to the screen that was on the display when you started the procedure.

u To specify the number of decimal places (Fix)

Example To specify two decimal places

1 (Fix) 3 (2)

Press the function key that corresponds to the number of decimal places you want to specify (n = 0 to 9).

  • Displayed values are rounded off to the number of decimal places you specify.
Page 3 of the Casio CFX-9970G user manual — k Setting the Angle Unit (Angle)
Page 3 · click to enlarge
Page 3

u To specify the number of significant digits (Sci)

Example To specify three significant digits

2 (Sci) 4 (3)

Press the function key that corresponds to the number of significant digits you want to specify (n = 0 to 9). Displayed values are rounded off to the number of significant digits you specify. Specifying 0 makes the number of significant digits 10. o specify the exponential display range (Norm 1/Norm 2) Press 3 (Norm) to switch between Norm 1 and Norm 2. Norm 1: 10–2 (0.01)>|x|, |x| >1010 Norm 2: 10–9 (0.000000001)>|x|, |x| >1010 o specify the engineering notation display (Eng) Press 4 (Eng) to switch between engineering notation and standard notation. he indicator “/E” is on the display while engineering notation is in effect. he following are the 11 engineering notation symbols used by this calculator. SymbolMeaningUnitSymbolMeaningUnit EExa1018mmilli10–3 PPeta1015µmicro10–6 TTera1012nnano10–9 GGiga109ppico10–12 MMega106ffemto10–15 kkilo103
  • The engineering symbol that makes the mantissa a value from 1 to 1000 is automatically selected by the calculator when engineering notation is in effect.
Page 4 of the Casio CFX-9970G user manual — k Calculation Priority Sequence
Page 4 · click to enlarge
Page 4

k Inputting Calculations

When you are ready to input a calculation, first press A to clear the display. Next, input your calculation formulas exactly as they are written, from left to right, and press w to obtain the result.

Example 1 2 + 3 – 4 + 10 =

Example 2 2(5 + 4) ÷ (23 × 5) =

k Calculation Priority Sequence

This calculator employs true algebraic logic to calculate the parts of a formula in the following order:

1 Coordinate transformation Pol (x, y), Rec (r, θ)

Differentials, quadratic differentials, integrations, Σ calculations d/dx, d2/dx2, ∫dx, Σ, Mat, Solve, FMin, FMax, List¡Mat, Fill, Seq, SortA, SortD, Min, Max, Median, Mean, Augment, Mat¡List, List

ALGBR Mode unique commands

expand(, factor(, tExpand(, tCollect(, ∫ (, diff(, solve(, tanLine(, collect(, combine(, sequence(, sumSeq(, expToTrig(, trigToExp(, signum(

2 Type A functions

With these functions, the value is entered and then the function key is pressed. x2, x–1, x !, ° ’ ”, ENG symbols

3 Power/root ^(xy), x

4 Fractions a b/c

5 Abbreviated multiplication format in front of π, memory name, or variable name.

2π, 5A, X min, F Start, etc.

6 Type B functions

With these functions, the function key is pressed and then the value is entered.

, 3 , log, In, ex, 10x, sin, cos, tan, sin–1, cos–1, tan–1, sinh, cosh, tanh, sinh–1, cosh–1, tanh–1, (–), d, h, b, o, Neg, Not, Det, Trn, Dim, Identity, Sum, Prod, Cuml, Percent, AList

7 Abbreviated multiplication format in front of Type B functions

2 , A log2, etc. 3

8 Permutation, combination nPr, nCr

9 × , / (÷)

Show 4 more labels / short text on this page
Ac+d-e+baw · Ac(f+e)/ · (cd*f)w · 0 +, –
Page 5 of the Casio CFX-9970G user manual — k Multiplication Operations without a Multiplication Sign
Page 5 · click to enlarge
Page 5

=, G , >, <, ≥ , ≤

# Or, or, xor, xnor

  • Execution is normally performed from left to right, except in the following cases when it is performed from right to left.

·When functions with the same priority are used in series: exIn → ex{In( )} 120 120

·When power calculations are used in series in the ALGBR Mode: [5^3^2 → 5^(3^2)]

·To produce the same result in the RUN Mode, the above calculation should be input: (5^3)^2

  • Compound functions are executed from right to left.
  • Anything contained within parentheses receives highest priority.

Example 2 + 3 × (log sin2π2 + 6.8) = 22.07101691 (angle unit = Rad)

k Multiplication Operations without a Multiplication Sign

You can omit the multiplication sign (×) in any of the following operations.

Example 2sin30, 10log1.2, 2 , 2Pol(5, 12), etc. 3

  • Before constants, variable names, memory names

Example 2π, 2AB, 3Ans, 3Y1, etc.

  • Before an open parenthesis

Example 3(5 + 6), (A + 1)(B – 1), etc.

! Relational operator · @ And, and

Page 6 of the Casio CFX-9970G user manual — Example 3 × 10 5 ÷ 7 – 42857 =
Page 6 · click to enlarge
Page 6

k Stacks

The unit employs memory blocks, called stacks, for storage of low priority values and commands. There is a 10-level numeric value stack, a 26-level command stack, and a 10-level program subroutine stack. An error occurs if you perform a calculation so complex that it exceeds the capacity of available numeric value stack or command stack space, or if execution of a program subroutine exceeds the capacity of the subroutine stack.

Numeric Value Stack Command Stack

b× c( d( e+ f× g( h+ ...
  • Calculations are performed according to the priority sequence. Once a calculation is executed, it is cleared from the stack.
  • Storing a complex number takes up two numeric value stack levels.
  • Storing a two-byte function takes up two command stack levels.

k Input, Output and Operation Limitations

The allowable range for both input and output values is 10 digits for the mantissa and 2 digits for the exponent. Internally, however, the unit performs calculations using 15 digits for the mantissa and 2 digits for the exponent.

Example 3 × 10 5 ÷ 7 – 42857 =

AdEf/hw

Example · dEf/h- · ecifhw

Page 7 of the Casio CFX-9970G user manual — k Overflow and Errors
Page 7 · click to enlarge
Page 7

k Overflow and Errors

Exceeding a specified input or calculation range, or attempting an illegal input causes an error message to appear on the display. Further operation of the calculator is impossible while an error message is displayed. The following events cause an error message to appear on the display.

  • When any result, whether intermediate or final, or any value in memory exceeds ± 9.999999999 × 10 99 (Ma ERROR).
  • When an attempt is made to perform a function calculation that exceeds the input range (Ma ERROR).
  • When an illegal operation is attempted during statistical calculations (Ma ERROR). For example, attempting to obtain 1VAR without data input.
  • When the capacity of the numeric value stack or command stack is exceeded (Stk ERROR). For example, entering 25 successive ( followed by 2 + 3 * 4 w .
  • When an attempt is made to perform a calculation using an illegal formula (Syn ERROR). For example, 5 ** 3 w .
  • When you try to perform a calculation that causes memory capacity to be exceeded (Mem ERROR).
  • When you use a command that requires an argument, without providing a valid argument (Arg ERROR).
  • When an attempt is made to use an illegal dimension during matrix calculations (Dim ERROR).
  • When no solution exists for an ALGBR Mode operation (Undefined).
  • When the result of an ALGBR Mode operation exceeds the range of the calculator (Overflow ERROR).
  • When a value input in the ALGBR Mode is outside the domain of the operation being performed (Domain ERROR).
  • When an ALGBR Mode operation in which only real numbers have been input produces a result that is a complex number while the set up screen's Answer Type item is specified as "Real" (Non-Real ERROR).
  • When no solution can be obtained using the Solve Function in the ALGBR Mode (No Solution).
  • When an attempt is made to use approx with an expression that generates an error unique to the ALGBR Mode (Ma ERROR).
  • Other errors can occur during program execution. Most of the calculator’s keys are inoperative while an error message is displayed. You can resume operation using one of the two following procedures.
  • Press the A key to clear the error and return to normal operation.
  • Press d or e to display the error.
Page 8 of the Casio CFX-9970G user manual — k Editing Calculations
Page 8 · click to enlarge
Page 8

k Memory Capacity

Each time you press a key, either one byte or two bytes is used. Some of the functions that require one byte are: b, c, d, sin, cos, tan, log, In, , and π. Some of the functions that take up two bytes are d/dx(, Mat, Xmin, If, For, Return, DrawGraph, SortA(, PxIOn, Sum, and an+1.

When the number of bytes remaining drops to five or below, the cursor automati- cally changes from “ _ ” to “ v ”. If you still need to input more, you should divide your calculation into two or more parts.

  • As you input numeric values or commands, they appear flush left on the display. Calculation results, on the other hand, are displayed flush right, except in the ALGBR Mode.

k Graphic Display and Text Display

The unit uses both a graphic display and a text display. The graphic display is used for graphics, while the text display is used for calculations and instructions. The contents of each type of display are stored in independent memory areas.

uTo switch between the graphic display and text display

Press !6(G↔T). You should also note that the key operations used to clear each type of display are different.

uTo clear the graphic display

Press !4(Sketch) 1(Cls) w.

uTo clear the text display

Press A.

k Editing Calculations

Use the d and e keys to move the cursor to the position you want to change, and then perform one of the operations described below. After you edit the calculation, you can execute it by pressing w, or use e to move to the end of the calculation and input more.

uTo change a step

Example To change cos60 to sin60

cga · ddd · s

Page 9 of the Casio CFX-9970G user manual — k Memory Capacity
Page 9 · click to enlarge
Page 9

uTo delete a step

Example To change 369 × × 2 to 369 × 2

uTo insert a step

Example To change 2.362 to sin2.362

c.dgx

  • When you press ![ the insert location is indicated by the symbol ‘‘ t ’’. The next function or value you input is inserted at the location of ‘‘ t ’’. To abort the insert operation without inputting anything, move the cursor, press ![ again, or press d , e or w .
Show 5 more labels / short text on this page
dgj**c · ddD · ddddd · ![ · s
Page 10 of the Casio CFX-9970G user manual — k Variables
Page 10 · click to enlarge
Page 10

1-2 Memory

k Variables

This calculator comes with 28 variables as standard. You can use variables to store values to be used inside of calculations. Variables are identified by single- letter names, which are made up of the 26 letters of the alphabet, plus r and θ. The maximum size of values that you can assign to variables is 15 digits for the mantissa and 2 digits for the exponent. Variable contents are retained even when you turn power off.

uTo assign a value to a variable

[value] a [variable name] w

Example To assign 123 to variable A

AbcdaaAw

Example To add 456 to variable A and store the result in variable B

AaA+efgaaBw

uTo display the contents of a variable

Example To display the contents of variable A

uTo clear a variable

Example To clear variable A

AaaaAw

  • To clear all variables, select “Memory Usage” from the SYS Mode.

uTo assign the same value to more than one variable

[value]a [first variable name]a3(~) [last variable name]w

  • You cannot use “ r ” or “ θ ” as a variable name in the above operation.

Example To assign a value of 10 to variables A through F

Abaa!aA

3(~)Fw

AaAw

Page 11 of the Casio CFX-9970G user manual — 4 (SEE)
Page 11 · click to enlarge
Page 11

Memory 1 - 2

k Function Memory [OPTN] - [FMEM]

Function memory is convenient for temporary storage of often-used expressions. For longer term storage, we recommend that you use the GRAPH Mode for expressions and the PRGM Mode for programs.

  • { STO } / { RCL } / { fn } / { SEE } ... {function store}/{function recall}/{function area specification as a variable name inside an expression}/{function list}

uTo store a function

Example To store the function (A+B) (A–B) as function memory number 1

K6(g)6(g)3(FMEM)A

(aA+aB)

(aA-aB)

1(STO) 1(f1)

  • If the function memory number you assign a function to already contains a function, the previous function is replaced with the new one.

uTo recall a function

Example To recall the contents of function memory number 1

K6(g)6(g)3(FMEM)A

2(RCL)1(f1)

  • The recalled function appears at the current location of the cursor on the display.

uTo display a list of available functions

K6(g)6(g)3(FMEM)

Casio CFX-9970G — k Function Memory [OPTN] - [FMEM] diagram (page 11)
Fig. 1 · k Function Memory [OPTN] - [FMEM]

4 (SEE)

Page 12 of the Casio CFX-9970G user manual — k Memory Status
Page 12 · click to enlarge
Page 12

1 - 2 Memory

uTo delete a function

Example To delete the contents of function memory number 1

K6(g)6(g)3(FMEM)A

1(STO) 1(f1)

  • Executing the store operation while the display is blank deletes the function in the function memory you specify.

uTo use stored functions

Once you store a function in memory, you can recall it and use it for a calculation. This feature is very useful for quick and easy input of functions when programming or graphing.

Example To store x3 + 1, x2 + x into function memory, and then graph: y = x3 + x2 + x + 1

Use the following View Window parameters.

Xmin = –4 Ymin = –10

Xmax = 4 Ymax = 10

Xscale = 1 Yscale = 1

!Zc1(Y=)JK6(g)6(g)3(FMEM)

AvMd+b1(STO)1(f1)(stores (x3 + 1))

Avx+v1(STO)2(f2)(stores (x2 + x))

A!4(Sketch)1(Cls)w

Casio CFX-9970G — 1 - 2 Memory diagram (page 12)
Fig. 2 · 1 - 2 Memory

!4(Sketch)5(GRPH)1(Y=)

K6(g)6(g)3(FMEM)

3(fn)1(f1)+2(f2)w

  • For full details about graphing, see “8. Graphing”.

k Memory Status

You can check how much memory is used for storage for each type of data. You can also see how many bytes of memory are still available for storage.

uTo check the memory status

1. In the Main Menu, select the SYS icon and press w .
Casio CFX-9970G — k Memory Status diagram (page 12)
Fig. 3 · k Memory Status
Page 13 of the Casio CFX-9970G user manual — Memory 1 - 2
Page 13 · click to enlarge
Page 13

Memory 1 - 2

2. Press c w to display the memory status screen.
Casio CFX-9970G — Memory 1 - 2 diagram (page 13)
Fig. 4 · Memory 1 - 2

Number of bytes still free

3. Use f and c to move the highlighting and view the amount of memory (in bytes) used for storage of each type of data.

The following table shows all of the data types that appear on the memory status screen.

Statistics Statistical calculations and graphs

Matrix Matrix memory data

List File List data

Draw Memory Graph drawing conditions (View Window, enlargement/reduction factor, graph screen)

Graph Memory Graph memory data

View Window View Window memory data

Picture Graph screen data

Dynamic Graph Dynamic Graph data

Table Function Table & Graph data

Recursion Recursion Table & Graph data

Equation Equation calculation data

Alpha Memory Alpha memory data

Function Mem Function memory data

Show 4 more labels / short text on this page
Data Type Meaning · Program Program data · Y= Graph functions · Financial Financial data
Page 14 of the Casio CFX-9970G user manual — k Clearing Memory Contents
Page 14 · click to enlarge
Page 14

1 - 2 Memory

k Clearing Memory Contents

Use the following procedure to clear data stored in memory.

1. In the memory status screen, use f and c to move the highlighting to the data type you want to clear.

If the data type you select in step 1 allows deletion of specific data

2. Press 1 (DEL).

1 2 3 4 5 6

* This menu appears when you select List File.

3. Press the function key that corresponds to the data you want to delete.

1 2 3 4 5 6

  • The above example shows the function menu that appears when you highlight {List File} in step 1.
4. Press 1 (YES).

If the data type you select in step 1 allows deletion of all data only

2. Press 1 (DEL).

1 2 3 4 5 6

3. Press 1 (YES) to delete all of the data.
Page 15 of the Casio CFX-9970G user manual — RECUR and EQUA Modes
Page 15 · click to enlarge
Page 15

1-3 Option (OPTN) Menu

The option menu gives you access to scientific functions and features that are not marked on the calculator’s keyboard. The contents of the option menu differ according to the mode you are in when you press the K key.

See the Command List at the back of this user’s guide for details on the option (OPTN) menu.

uOption Menu in the RUN and PRGM Modes

  • { LIST } ... {list function menu}
  • { MAT } ... {matrix operation menu}
  • { CPLX } ... {complex number calculation menu}
  • { CALC } ... {functional analysis menu}
  • { STAT } ... {paired-variable statistical estimated value menu}
  • { COLR } ... {graph color menu}
  • { HYP } ... {hyperbolic calculation menu}
  • { PROB } ... {probability/distribution calculation menu}
  • { NUM } ... {numeric calculation menu}
  • { ANGL } ... {menu for angle/coordinate conversion, sexagesimal input/ conversion}
  • { ESYM } ... {engineering symbol menu}
  • { PICT } ... {graph save/recall menu}
  • { FMEM } ... {function memory menu}
  • { LOGIC } ... {logic operator menu}

Pressing K causes the following function key menu to appear while binary, octal, decimal, or hexadecimal is set as the default number system.

  • { COLR } ... {graph color menu}

uOption Menu during numeric data input in the STAT, MAT, LIST,

TABLE, RECUR and EQUA Modes

  • { LIST } / { HYP } / { PROB } / { NUM } / { ANGL } / { ESYM } / { FMEM } / { LOGIC }

uOption Menu during formula input in the GRAPH, DYNA, TABLE,

RECUR and EQUA Modes

  • { List } / { CALC } / { HYP } / { PROB } / { NUM } / { FMEM } / { LOGIC }

uOption Menu during expression input in the ALGBR Mode

  • { Abs } / { HYP } / { i } / { x ! } / { sign } / { FMEM }

The meanings of the option menu items are described in the sections that cover each mode.

Page 16 of the Casio CFX-9970G user manual — P.259 P.267
Page 16 · click to enlarge
Page 16

To recall variable data, press J to display the variable data menu.

{V-WIN}/{FACT}/{STAT}/{GRPH}/{DYNA}/{TABL}/{RECR}/{EQUA}/{TVM}

See the Command List at the back of this user’s guide for details on the variable data (VARS) menu.

  • Note that the EQUA and TVM items appear for function keys ( 3 and 4 ) only when you access the variable data menu from the RUN or PRGM Mode.
  • The variable data menu does not appear if you press J while binary, octal, decimal, or hexadecimal is set as the default number system.

k V-WIN — Recalling View Window values

Selecting {V-WIN} from the VARS menu displays the View Window value recall menu.

u {X}/{Y}/{T,θ } ... {x-axis menu}/{y-axis menu}/{T, θ menu}

u {R-X}/{R-Y}/{R-T,θ } ... {x-axis menu}/{y-axis menu}/{T,θ menu} for right side

of Dual Graph The following are the items that appear in the above menus.

  • { min } / { max } / { scal } / { ptch } ... {minimum value}/{maximum value}/{scale}/ {pitch}

k FACT — Recalling enlargement/reduction factors

Selecting {FACT} from the VARS menu displays the enlargement/reduction factor recall menu.

  • { Xfct } / { Yfct } ... { x -axis factor}/{ y -axis factor}

k STAT — Recalling Single/Paired-variable Statistical Data

Selecting {STAT} from the VARS menu displays the single/paired-variable statistical data recall menu.

{X}/{Y}/{GRPH}/{PTS}/{TEST}/{RESLT}

u {X}/{Y} ... {x-data menu}/{y-data menu} The following are the items that appear in the above menus.

  • { n } ... {number of data}

P.259 P.267

  • { o } / { p } ... mean of { x -data}/{ y -data}
  • { Σ x } / { Σ y } ... sum of { x -data}/{ y -data}
  • { Σ x 2 } / { Σ y 2 } ... sum of squares of { x -data}/{ y -data}
  • { Σ xy } ... {sum of products of x -data and y -data}
Page 17 of the Casio CFX-9970G user manual — k V-WIN — Recalling View Window values
Page 17 · click to enlarge
Page 17
  • { x σ n } / { y σ n } ... population standard deviation of { x -data}/{ y -data}
  • { x σ n -1 } / { y σ n -1 } ... sample standard deviation of { x -data}/{ y -data}
  • { minX } / { minY } ... minimum value of { x -data}/{ y -data}
  • { maxX } / { maxY } ... maximum value of { x -data}/{ y -data}

u {GRPH} ...{graph data menu} The following are the items that appear in the above menu.

  • { a } / { b } / { c } / { d } / { e } ... {regression coefficient and multinomial coefficients}
  • { r } ... {correlation coefficient}
  • { Q1 } / { Q3 } ... {first quartile}/{third quartile}
  • { Med } / { Mod } ... {median}/{mode} of input data
  • { Strt } / { Pitch } ... histogram {start division}/{pitch}
  • { Iter } / { Perid } ... sine regression {number of iterations}/{period}

u {PTS} ... {summary point data menu} The following are the items that appear in the above menu.

  • { x 1 } / { y 1 } / { x 2 } / { y 2 } / { x 3 } / { y 3 } ... {coordinates of summary points}

u {TEST} ... {test data recall} The following are the items that appear in the above menu.

  • { n } / { o } / { x σ n -1 } ... {number of data}/{data mean}/{sample standard deviation}
  • { n 1 } / { n 2 } ... number of {data 1}/{data 2}
  • { o 1 } / { o 2 } ... mean of {data 1}/{data 2}
  • { x 1 σ } / { x 2 σ } ... sample standard deviation of {data 1}/{data 2}
  • { x p σ } ... {pooled sample standard deviation}
  • { F } ... { F value}
  • { Fdf } / { SS } / { MS } ... factor {degrees of freedom}/{sum of squares}/{mean of squares}
  • { Edf } / { SSe } / { MSe } ... error {degrees of freedom}/{sum of squares}/{mean of squares}

u {RESLT} ... {test result recall} The following are the items that appear in the above menu.

  • { p } ... {p value}
  • { z } / { t } / { Chi } / { F } ... { Z test results}/{ t test results}/{ χ 2 test results}/{ F test results}
  • { Left } / { Right } ... {interval lower limit (left edge)}/{interval upper limit (right edge)}
  • { ˆp } / { ˆp 1 } / { ˆp 2 } ... {expected probability value}/{expected probability value 1}/ {expected probability value 2}
  • { df } / { s } / { r } / { r 2 } ... {degrees of freedom}/{standard error}/{correlation coefficient}/{coefficient of determination}
Page 18 of the Casio CFX-9970G user manual — k TABL — Recalling Table & Graph Set Up and Content Data
Page 18 · click to enlarge
Page 18

k GRPH — Recalling Graph Functions

Selecting {GRPH} from the VARS menu displays the graph function recall menu.

  • { Y } / { r } ... {rectangular coordinate or inequality function}/{polar coordinate function}
  • { Xt } / { Yt } ... parametric graph function {Xt}/{Yt}
  • { X } ... {X=constant graph function}

(Press these keys before inputting a value to specify a storage area.)

Example To recall and draw the graph for the rectangular coordinate function y = 2 x2 – 3, which is stored in storage area Y2

Use the following View Window parameters to draw the graph.

Xmin = –5 Ymin = –5

Xmax = 5 Ymax = 5

Xscale = 1 Yscale = 1

!4(Sketch)5(GRPH)1(Y=)

Casio CFX-9970G — k GRPH — Recalling Graph Functions diagram (page 18)
Fig. 5 · k GRPH — Recalling Graph Functions

J4(GRPH)1(Y)cw

k DYNA — Recalling Dynamic Graph Set Up Data

Selecting {DYNA} from the VARS menu displays the Dynamic Graph set up data recall menu.

  • { Strt } / { End } / { Pitch } ... {coefficient range start value}/{coefficient range end value}/{coefficient value increment}

k TABL — Recalling Table & Graph Set Up and Content Data

Selecting {TABL} from the VARS menu displays the Table & Graph set up and content data recall menu.

  • { Strt } / { End } / { Pitch } ... {table range start value}/{table range end value}/{table value increment}
  • { Reslt } ... {matrix of table contents}
  • The Reslt item appears for function key 4 only when the above menu is displayed in the RUN or PRGM Mode.
Page 19 of the Casio CFX-9970G user manual — k RECR — Recalling Recursion Formula, Table Range, and
Page 19 · click to enlarge
Page 19

Example To recall the contents of the numeric table for the function y = 3x2 – 2, while the table range is Start=0 and End=6, and pitch=1

Casio CFX-9970G — k RECR — Recalling Recursion Formula, Table Range, and diagram (page 19)
Fig. 6 · k RECR — Recalling Recursion Formula, Table Range, a…

k RECR — Recalling Recursion Formula, Table Range, and

Table Content Data

Selecting {RECR} from the VARS menu displays the recursion data recall menu.

u {FORM} ... {recursion formula data menu} The following are the items that appear in the above menu.

  • { a n } / { a n +1 } / { a n +2 } / { b n } / { b n +1 } / { b n +2 } ... { a n }/{ a n +1 }/{ a n +2 }/{ b n }/{ b n +1 }/{ b n +2 } expressions

u {RANG} ... {table range data menu} The following are the items that appear in the above menu.

  • { Strt } / { End } ... {table range start value}/{table range end value}
  • { a 0 } / { a 1 } / { a 2 } ... {zero term a o value}/{first term a 1 value}/{second term a 2
  • { b 0 } / { b 1 } / { b 2 } ... {zero term b o value}/{first term b 1 value}/{second term b 2 value}
  • { a n St } / { b n St } ... origin of { a n }/{ b n } recursion formula convergence/divergence graph (WEB graph)

u {Reslt} ... {matrix of table contents}

Selecting {Reslt} displays a matrix that shows the contents of the recursion table.

  • This operation is available only in the RUN and PRGM modes.

Example To recall the contents of the numeric table for recursion formula an = 2n + 1, while the table range is Start=1 and End=6

Casio CFX-9970G — k RECR — Recalling Recursion Formula, Table Range, and diagram (page 19)
Fig. 7 · k RECR — Recalling Recursion Formula, Table Range, a…

4(Reslt)w · value} · 3(Reslt)w

Page 20 of the Casio CFX-9970G user manual — 2 x 2 + x – 10 = 0
Page 20 · click to enlarge
Page 20
  • The table contents recalled by the above operation are stored automatically in Matrix Answer Memory (MatAns).
  • An error occurs if you perform the above operation when there is no function or recursion formula numeric table in memory.

k EQUA — Recalling Equation Coefficients and Solutions

Selecting {EQUA} from the VARS menu displays the equation coefficient and solution recall menu.

  • { S-Rlt } / { S-Cof } ... matrix of {solutions}/{coefficients} for linear equations with two through six unknowns
  • { P-Rlt } / { P-Cof } ... matrix of {solution}/{coefficients} for a quadratic or cubic equation

Example 1 To recall the solutions for the following linear equations with two unknowns

2x + 3y = 8 3x + 5y = 14

Example 2 To recall the coefficients for the following linear equations with three unknowns

4x + y – 2z = –1 x + 6y + 3z = 1 –5x + 4y + z = –7

Example 3 To recall the solutions for the following quadratic equation

2 x 2 + x – 10 = 0

Example 4 To recall the coefficients for the following quadratic equation

2 x 2 + x – 10 = 0

Show 4 more labels / short text on this page
1(S-Rlt)w · 2(S-Cof)w · 3(P-Rlt)w · 4(P-Cof)w
Page 21 of the Casio CFX-9970G user manual — k TVM — Recalling Financial Calculation Data
Page 21 · click to enlarge
Page 21
  • The coefficients and solutions recalled by the above operation are stored automatically in Matrix Answer Memory (MatAns).
  • When the solutions for a linear equation with 2 through 6 unknowns contain complex numbers, only the real number parts are stored in Matrix Answer Memory (MatAns).
  • Coefficient and solution memory data for a linear equation with 2 though 6 unknowns cannot be recalled at the same time.
  • The following conditions cause an error to be generated.

— When there are no coefficients input for the equation

— When there are no solutions obtained for the equation

k TVM — Recalling Financial Calculation Data

Selecting {TVM} from the VARS menu displays the financial calculation data recall menu.

  • { n } / { I %} / { PV } / { PMT } / { FV } ... {payment periods (installments)}/{interest (%)}/ {present value}/{payment amount}/{future value}
  • { P / Y } / { C / Y } ... {number of installment periods per year}/{number of compounding periods per year}
Page 22 of the Casio CFX-9970G user manual — 1-5 Program (PRGM) Menu
Page 22 · click to enlarge
Page 22

1-5 Program (PRGM) Menu

To display the program (PRGM) menu, first enter the RUN or PRGM Mode from the Main Menu and then press ! W. The following are the selections available in the program (PRGM) menu.

  • { COM } … {program command menu}
  • { CTL } … {program control command menu}
  • { JUMP } … {jump command menu}
  • { ? } … {input command}
  • { ^ } … {output command}
  • { CLR } … {clear command menu}
  • { DISP } … {display command menu}
  • { REL } … {conditional jump relational operator menu}
  • { I/O } … {input/output control command menu}
  • { : } … {multistatement connector}

The function key menu appears if you press ! W in the RUN Mode or the PRGM Mode while binary, octal, decimal, or hexadecimal is set as the default number system.

  • { Prog } / { JUMP } / { ? } / { ^ } / { REL } / { : }

The functions assigned to the function keys are the same as those in the Comp Mode.

For details on the commands that are available in the various menus you can access from the program menu, see “21. Programming”. P.365

Ask about the Casio CFX-9970G

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Casio CFX-9970G

Be the first to ask — other owners or our team will answer.

Original document

Casio CFX-9970G manual PDF

22 pages·102 KB·Calculator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…