9.13 RPN (64H,65H) 13 9.13.1 Pitch Bend Sensitivity 14 9.13.2 Fine Tune 14 9.13.3 Coarse Tune 14 9.13.4 Null 15 9.14 All Sound Off (78H) 15 9.15 Reset All Controllers (79H) 15
10 Mode Message 16 10.1 All Notes Off (7BH) 16 10.2 Omni Off (7CH) 16 10.3 Omni On (7DH) 16 10.4 Mono (7EH) 16 10.5 Poly (7FH) 17
11 Program Change 17 11.1 About the Timbre Type 17
12 Channel Aftertouch 18
13 Pitch Bend 18
14 TimingClock 19
15 Start 19
16 Stop 19
17 Active Sensing 19
18 System Exclusive Message 20 18.1 Universal Realtime System Exclusive Message 20 18.1.1 Master Volume 20 18.1.2 Master Fine Tuning 20 18.1.3 Master Coarse Tuning 21 18.1.4 Reverb Parameter 21 18.1.5 Chorus Parameter 21 18.1.6 GM System Message 22 18.1.7 GS Message 23 18.2 Instrument-Specific System Exclusive Message 23
19 Format 24 19.1 Message Classifications 24 19.2 Basic Message Structure 25

19.3 Format of Each Field 25 19.3.1 SX : System Exclusive Message Status 25 19.3.2 MAN : Manufacturer's ID 25 19.3.3 MOD : Model ID 25 19.3.4 dev: MIDI Device ID 00H-7FH 26 19.3.5 act : Action 26 19.3.6 cat : Category 28 19.3.7 mem : Memory Area ID 28 19.3.8 pset : Parameter Set Number 28 19.3.9 blk : Block Number 29 19.3.10 pkt : Packet Number 29 19.3.11 prm : Parameter ID 29 19.3.12 idx : Data Index Number 29 19.3.13 len : Data Length 30 19.3.14 data : Parameter Data 30 19.3.15 Single Parameter Data Size Limit 30 19.3.16 img : Parameter Set Image 31 19.3.17 sum : Check Sum 31 19.3.18 EOX : End of System Exclusive Message 31
20 Individual Parameter Operations 32
21 Parameter Set Transfer 32 21.1 Communication Modes 32 21.1.1 One-way and Handshake 32 21.1.2 Session and Subsession 33 21.2 One-way Mode Communication Flow 33 21.3 Handshake Mode Communication Flow 34
22 Using the Parameter List 38
23 System Parameters 38 23.1 System Information Parameter 38 23.2 Data Management Parameter 39
24 Patch Parameters 40 24.1 Master Tune Parameter 40 24.2 Master Mixer Parameter 40 24.3 Part Parameter 40
25 Scale Memory Parameter 41
26 Song Parameter 41
27 Rhythm Parameter 41
28 Sequence Parameter 41
29 Lesson Rec Parameter 41
30 Registration Parameter 42

31 All Data Parameter 42
32 Parameter Set Table 43
33 Setting Value Tables 44 33.1 Off/On Setting Value Table 44 33.2 -64 - 0 - +63 Setting Value Table 44 33.3 Pan Setting Value Table 44 33.4 -100 - 0 - +99 Setting Value Table 44 33.5 Reverb Time Setting Value Table 44 33.6 Chorus Type Setting Value Table 44
34 Value Notation 45 34.1 Hexadecimal Notation 45 34.2 Binary Notation 45

1 Product Configuration as a MIDI Device
In terms of a MIDI device, this Instrument consists of a System Section, Performance Controller Section, and Sound Generator Section. Each of these sections can send and receive specific MIDI Messages in accordance with its function.
The System Section manages the Instrument status and user data. A communication method known as a "bulk dump" is supported, which allows two-way transfer of user data between the Instrument and a computer.
The Performance Controller Section performs keyboard play and controller operations, and generates performance messages in accordance with auto play, etc. Basically, generated performance messages are sent to external destinations while also being transmitted to the Sound Generator Section. The channel number of the sent channel message is in accordance with Instrument's instrument part number.
MIDI Output Performance Information The following describes the performance information that is output and is not output as MIDI signals.
– Keyboard play by the performer
The Sound Generator Section consists of a channel-independent common block and an independent instrument part specific to each channel. Mainly it receives performance information and sound source setting information.
The common block consists of system effects, mixer master control, etc. These can be controlled by system exclusive messages that are basically exclusive to this particular instrument, but several parameters also can be controlled by general universal system exclusive messages.

The instrument parts of the sound generator can be operated or their settings can be changed with Instrument-specific system exclusive messages and channel messages. The 32 instrument parts of this Instrument are divided between Group A and Group B, each of which has 16 instrument parts. Only Group B can be controlled by external channel messages. As shown in the following table, there is a fixed relationship between channel message receive channel numbers and instrument parts.

The sound source operation performed for a received message depends on the current Timbre Type value (see "11.1 About the Timbre Type), which is the operation mode of each sound generator instrument part. For details, see the explanation for each message.
All MIDI message send and receive is temporarily disabled while any one of the following processes is in progress.

4 Receive Channel
The channel number of the channel message received by each part is shown in the table under "1.3.2 Instrument Part Block".
Basically, the MIDI channel of the channel message sent when the Instrument is played coincides with the MIDI channel of the part being played. Note, however, that the MIDI channel of the performance information that corresponds to the keyboard main part is the Keyboard Channel setting value.
Send Sent when something is played on the keyboard or when auto accompaniment is used. For keyboard play, the key number range is changed in accordance with the octave shift function.
Receive Received by Instrument parts corresponding to MIDI. The velocity value is ignored. A part that is turned off by the Part Enable Parameter value explained under "24.3 Part Parameter" is not received.
Send Sent when something is played on the keyboard. The key number range is changed in accordance with the octave shift function.
Receive Received by Instrument parts corresponding to MIDI. The velocity value is ignored. A part that is turned off by the Part Enable Parameter value explained under "24.3 Part Parameter" is not received.

Send This message is not sent by this Instrument.
Receive This message is not received by this Instrument.
Send Sent when the Instrument's pedal is operated or when Instrument settings are changed.
Receive Receipt changes the pedal and other performance conditions, and Instrument settings.
Send Sent when a tone is selected. The LSB value is always 00H.
Receive Receipt causes a change in the tone bank number stored in Instrument memory, but the tone is not actually changed until a Program Change message is received. For details, see "11 Program Change". The LSB value is ignored.

Send This message is not sent by this Instrument.
Receive Receipt adds, to the tone being sounded, modulation of a depth specified by the value. In the case of a tone that already has modulation applied, receipt of this message increases the modulation depth. The modulation effect differs according to the tone being used.
Send Sent when there is a change to the parameter assigned to RPN. This Instrument does not have a parameter that corresponds to NRPN.
Receive Receipt changes the parameter assigned to RPN. This Instrument does not have a parameter that corresponds to NRPN.
Send Sent when auto accompaniment is used.
Receive Receipt changes the volume of the corresponding part.

Send Sent when auto accompaniment is used.
Receive Receipt changes the pan setting of the corresponding part.
Send Sent when auto accompaniment is used.
Receive Receipt changes the Expression value.
Send Sent when a pedal that has a sustain (damper) function is operated.
Receive Receipt performs an operation equivalent to a sustain pedal operation.

Timbre Type Specific Operation This operation differs in accordance with the Timbre Type (see "11.1 About the Timbre Type") setting.
Send Sent when a pedal that has a sostenuto function is operated.
Receive Receipt performs an operation equivalent to a sostenuto pedal operation.
Send Sent when a pedal that has a soft function is operated.
Receive Receipt performs an operation equivalent to a soft pedal operation.

Send Sent when auto accompaniment is used.
Receive Changes Reverb Send.
n: MIDI Channel Number
Send Sent when auto accompaniment is used and when a Chorus on/off operation is performed.
Receive Changes Chorus Send.
n: MIDI Channel Number
Send This message is not sent by this Instrument.
Receive This Instrument does not have a corresponding NRPN message.
n: MIDI Channel Number

n: MIDI Channel Number
Send Sent when the Bend Range is changed on the CTK-5000, WK-500, or CDP-200R.
Receive Receipt changes Bend Range.
n: MIDI Channel Number
Send This message is not sent by this Instrument.
Receive Receipt changes Channel Fine Tune.
n: MIDI Channel Number
Send 00H · Receive Ignored

Send This message is not sent by this Instrument.
Receive Receipt changes Channel Coarse Tune. Does not affect sound source operation when the Timbre Type is Drum.
n: MIDI Channel Number
Send Sent after the Bend Range is changed on the CTK-5000, WK-500, or CDP-200R.
Receive Receipt deselects RPN.
n: MIDI Channel Number
Send Sent when Local is set to OFF on the Instrument.
Receive Receipt stops all voices that are sounding.
n: MIDI Channel Number
Send Sent when MIDI send related settings are changed on the Instrument.
Receive Receipt initializes each performance controller.

n: MIDI Channel Number
Send Sent when MIDI send related settings are changed on the Instrument, or when auto play is stopped, etc.
Receive Receipt of any of this message releases the currently sounding voice (same as releasing the keyboard key).
n: MIDI Channel Number
Send This message is never sent.
Receive Receipt of this message performs the same operation as when All Notes Off is received.
n: MIDI Channel Number
Send This message is never sent.
Receive Receipt of this message performs the same operation as when All Notes Off is received.
n: MIDI Channel Number
Send This message is never sent.
Receive Receipt of this message performs the same operation as when All Notes Off is received.

n: MIDI Channel Number
Send This message is never sent.
Receive Receipt of this message performs the same operation as when All Notes Off is received.
n: MIDI Channel Number
Send Sent when a tone is selected.
Receive Receipt of this message changes the tone of the part that corresponds to the MIDI channel. The selected tone is determined by the program value of this message and the Bank Select message value received prior to this message. Also note that receipt of this message also may change the Timbre Type that corresponds to the selected tone. For more information, see "11.1 About the Timbre Type" below.
Tones that are selected by each Instrument part have an attribute that depends on the sound source operation type. This attribute is called the "timbre type," which is one of the types described below.

n: MIDI Channel Number
Send These messages are never sent.
Receive Receipt of this message adds modulation to the voice that is sounding. The modulation effect differs according to the tone being used.
n: MIDI Channel Number
Send Sent when a pitch bender operation is performed on the CTK-5000, WK-500, or CDP-200R.
Receive Receipt changes the pitch of the currently sounding note. The range of the pitch change depends on the Bend Range value setting.

14 Timing Clock
Send Sent when auto accompaniment is used.
Receive This message is not received by this Instrument.
Send Sent when auto accompaniment is used.
Receive This message is not received by this Instrument.
Send Sent when auto accompaniment is used.
Receive This message is not received by this Instrument.
Send This message is never sent.

Receive Once this message is received, the Active Sensing mode is entered. If no MIDI message is received for a specified amount of time, voices being sounded by the Instrument's sound source are released, the controller is reset, and the Active Sensing mode is exited.
The Instrument sends and receives standard universal system exclusive messages, and system exclusive messages that have Instrument-specific formats.
Send This message is never sent.
Receive Receipt changes the Master Volume parameter. Note that the Master Volume parameter cannot be changed with an Instrument operation.
Send This message is sent when the tuning setting is changed.
Receive Receipt changes the tuning setting.

Send Sent when Transpose is changed.
Receive Receipt changes the Transpose parameter. Does not affect sound source operation when the Timbre Type is Drum.
Send Sent when the Reverb duration is changed.
Receive Receipt changes the Reverb duration.
Time Format · Type Format

Send This message is sent when the System Chorus Type setting is changed.
Receive Receipt changes the System Chorus Type parameter.
Send This message is never sent.
Receive Receipt changes the System Chorus Rate parameter.
GM System On Format
Send This message is never sent.
Receive Receipt puts the sound source into a GM sound source mode.
GM System Off Format
Send This message is never sent.
Receive Receipt changes the sound source setting to the Instrument presetting.
GM2 System On Format
Send This message is never sent.
Receive Though the Instrument does not support GM2, receipt of the GM2 System On message has the same result as receipt of the GM System On message.
Rate Format

Send This message is never sent.
Receive Receipt performs the same operation as when the GM System On message is received.
This message can be used to send the Instrument memory status, for two-way transfer of special operation commands and user data, to perform sound source parameter operations, etc.
For more information, see "Part IV Instrument-Specific System Exclusive Messages".

This section explains the format of the Instrument-specific System Exclusive Messages. See "Part V Parameter List" and "Part VI Parameter Set List" for information about how parameter sets actually are transferred.
Basically, the operation that corresponds to Instrument-specific system exclusive messages is parameter data transfer. The following operations can be performed from an external device using this parameter transfer message.
In addition to parameters being used as device setting values, some parameters act as commands when received by the Instrument and as device status information when sent from the Instrument. The following table shows the parameter category for each type of transfer.
Function Section Parameter Category Description
System System Commands to the Instrument, Instrument stats
All All user data
Lesson Rec Recorder Song (Play-Along)
Scale Memory User Scale Memory
Sound Generator Patch Sound source common settings (system effects, master settings, etc.) Instrument part settings (tone selection, mixer channel setting, tuning, etc.)
Tone Sampled sound (melody/drum) selected by the user
Drum Sampled sound (drum) referenced from "Tone" category parameters
Instrument Individual instrument setting referenced from "Drum" category parameters
Wave Parameter Sampled sound Wave setting
Wave Data Waveform actual data referenced from "Wave Parameter" category parameters

Instrument-specific system exclusive message operation can be broadly divided between two methods: Individual Parameter Transfer (single parameter send/receive) and Bulk Parameter Set Transfer (batch parameter send/receive). Each method includes a number of different messages. The field in the SysEx message that specifies the message type is the action (act) field. The format of the "body" part of the message depends on the "act" value.
The table below shows the body format for each action of Instrument-specific system exclusive messages. An actual message consists of the items indicated by "Y", from left to right.
act SX MAN MOD dev act body (Depends on act) EOX
cat mem pset blk pkt prm idx len data img sum
NOP Y - Y
IPR Y - Y Y Y - - - Y
IPS Y - Y - - Y
OBR Y - Y
OBS Y - Y - - Y - Y Y Y
HBR Y - Y
HBS Y - Y - - Y - Y Y Y
ACK Y - Y
BSY - Y
RJC Y - Y
EOD Y - Y
EOS Y - Y
ERR Y - Y
19.3.1 SX : System Exclusive Message Status
System Exclusive message Status = F0H
Manufacturer's ID = 44H (CASIO)
The Model ID of the series to which the Instrument belongs is shown by two consecutive bytes (MSB, LSB). (CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200R Model ID MSB = 16H, LSB = 01H)

The contents of this field in a received message are compared with the Model's MIDI Device ID, and receipt of the incoming message is allowed only when the two IDs match. When a message containing 7FH is received, receipt of the message is always allowed, regardless of the Instrument's ID setting. Note, however, that the Instrument does not have a specific Device ID, so use only 7FH for send and receive.
aaaaaaaB = Action This field indicates the operation of the Instrument-specific System Exclusive Message.
00H NOP No Operation
01H IPR Individual Parameter Request
02H IPS Individual Parameter Send
03H OBR Oneway Bulk Parameter Set Request
04H OBS Oneway Bulk Parameter Set Send
05H HBR Handshake Bulk Parameter Set Request
06H HBS Handshake Bulk Parameter Set Send
0DH EOD End of Data
0EH EOS End of Session
NOP: No Operation No operation is performed when this action is received.
IPR: Individual Parameter Request Indicates an individual parameter value send request message. When the Instrument receives this action, it uses an IPS message to return the specified parameter value.
IPS: Individual Parameter Send Indicates an individual parameter value send message. When the Instrument receives this action, it rewrites the value specified by the data field with the specified parameter value.
OBR: Oneway Bulk Parameter Set Request Indicates a send request message using parameter set image one-way mode. When the Instrument receives this action, it uses an OBS message to return the specified parameter set.
OBS: Oneway Bulk Parameter Set Send Indicates a parameter set image send message using one-way mode. The parameter set to be transferred is divided into multiple packets when it is greater than a prescribed size. At this time, packets are transferred at intervals of the prescribed time (20 msec) or greater.
HBR: Handshake Bulk Parameter Set Request Indicates a send request message using the parameter set image handshake mode. When the Instrument receives this action, it uses an HBS message to return the specified parameter set.

HBS: Handshake Bulk Parameter Set Send Indicates a parameter set image send message using handshake mode. The parameter set to be transferred is divided into multiple packets when it is greater than a prescribed size. The packets are transferred in accordance with handshake mode.
ACK: Acknowledge Indicates a message used by the receiver during parameter set handshake mode transfer to convey to the sender that it is ready for send of the next packet. The cat, mem, and pset fields indicate the value carried by the last received message.
BSY: Busy Indicates a message to convey to the requester that that the Instrument cannot send back data after a parameter set one- way mode or handshake mode send request is received. The cat, mem, and pset fields indicate the value carried by the last received message.
RJC: Reject Indicates a message to convey to the other side that an ongoing parameter set one-way mode or handshake mode send or receive session was interrupted. The cat, mem, and pset fields indicate the value carried by the last received message.
EOD: End of Data Indicates a message to convey to the receiver that a one-way mode or handshake mode serial packet transfer for sending a sub-session (one parameter set) is complete. The cat, mem, and pset fields indicate the value carried by the last received message.
EOS: End of Session Indicates a message to convey to the receiver that a one-way mode or handshake mode serial parameter set transfer session send, which was launched by some operation, is complete. The cat, mem, and pset fields indicate the value carried by the last received message.
ERR: Error Indicates a message to convey to the sender that the checksum or message format of the previous packet was not correct when receiving a parameter set with handshake mode. The cat, mem, and pset fields indicate the value carried by the last received message.

0cccccccB = Category (7bit) The category indicates the categories of data handled by the System Exclusive Message. The ID number (ID) of the Category is indicated on the left, while the communication operation (Action) is indicated on the right.
ID (c) Parameter Set Individual Parameter One Way Bulk Handshake Bulk
00H System A - -
02H Patch A - -
03H Tone A A A
06H Drum A A A
0DH Instrument A A A
0EH Wave Parameter A A A
0FH Wave Data F A A
12H Scale Memory A A A
1FH All F A A
20H Song F A A
21H Sequence F A A
22H Registration F A A
23H Lesson Rec F A A
24H Rhythm F A A
A.. Available (Also including when only some parameters are available.) F... File Information (Not the data itself. Name, size, and other file information only.) -... Not Available
Specifies the memory area that is the object of the parameter transfer. The following are defined for this Instrument.
0 User area Read/write enabled
1 Preset area Read/write disabled
This field is a 2-byte (LSB, MSB) value indicating the number of the parameter set (mmmmmmmnnnnnnnB, Binary) being transferred.
Category Transfer · Mem Type Meaning

The block number is a supplementary number that specifies which block parameter is to be accessed.
Block Bit Field Division When the parameter block has a multi-dimensional array structure, bit 21 of the block number is divided into prescribed bit fields based on the rules explained below.
Example: parameter [A][B][C] With a 3-dimensional array parameter that consists of A=8 (3 bits), B=5 (3 bits) and C=10 (4 bits), the block bit fields are allocated as: Block = 0000aaa 000bbb ccccccc (Binary).
Example 1: parameter [A][B][C][D] With a 4-dimensional array parameter that consists of A=3 (2 bits), B=4 (2 bits), C=3 (2 bits) and D=4 (2 bits) like the one shown above, the block bit fields are allocated as: Block = 0000000 00000a abbccdd (Binary).
Example 2: parameter [A][B] A=3 (2 bits), B=200 (8 bits) With a 2-dimensional array parameter like the one shown above, the block bit fields are allocated as: Block = 0000000 000aab bbbbbbb (Binary).
This is the divided packet number kkkkkkkjjjjjjjiiiiiiiB (Binary) for transferring a single parameter set.
The Parameter ID indicates the parameter type. When transferring parameters (see "Part V Parameter List" below) individually (as opposed to bulk transfer), this field is used to identify the parameter being transferred by its parameter ID.
The data index number indicates the first array number of the array from which transfer starts.

As shown below, the meaning of this field differs depending on whether an individual transfer or a bulk parameter set transfer is being performed.
Individual Parameter Transfer Data length indicates the length of the array being transferred minus 1 when the parameter contains a character string or other similar array structure.
Bulk Parameter Set Transfer Data length indicates the number of bytes of data included within a packet. When this value is zero, it means there is no actual data.
: :
Parameter data indicates the parameter value. Data that is the size of the number of arrays equivalent to len + 1 follows. For the structure of one data item, the length depends on the data bit width, as shown below.
dddddB + 1 Number of Data
Each block of data is packed from the lowest order byte first. In the case of multiple-byte data, the lowest weighted bit is the LSB of the first "data" block, and the highest weighted bit is the MSB of the final "data" block. The following shows an example of how data would be divided for transfer in the case of 32-bit data.
7 6 5 4 3 2 1 0
With the Instrument's system exclusive message format, the size of a single message cannot exceed 256 bytes. The data size and the array size, however, can cause a packet to exceed 256 bytes when transferring a single parameter array. In this case, the IPS and IPR message data length and data index number values can be modified to enable division of a single parameter value into multiple messages so it can be sent that way.

For a bulk data transfer operation, the parameter set data to be transferred is read sequentially in 16-bit units starting from the top address. Read values are divided into 3-byte segments as shown below, and then sent in sequence.
The following is the conversion format, which is the same as the individual parameter 16-bit transfer detailed above.
If the length of the data being transferred is an odd number of bytes, the final bit field is filled in with zero.
Parameter Set Packet Division The maximum image size of the parameter set that can be sent with one packet is 128 bytes. When data that exceeds 128 bytes is transferred, data is always divided into 128-byte units, except for the final packet. Because of this, the data in received packets can be stored in an areas the size of [Parameter Set Start Address] + [Packet Number] × 128.
For bulk parameter set transfer, the 16-bit image is divided in 3-byte groups, so the img field length is the value produced by multiplying the len value (len + 1 when len is an odd number) by 3/2. Note, however, that a parameter set of 128 bytes or less can be sent using a single packet, and anything greater than 128 bytes is divided among multiple packets. This means that the maximum length "data" field is 128 × 3/2 = 192 bytes.
Only one parameter set can be transferred per session, and data from different parameter sets cannot be mixed within a single packet, even when sending multiple parameter sets. Different parameter sets are always divided into separate packets.
In this case, this "sum" field contains a value, which, when added to the total value of the "img" field, makes the lower seven bits 0. The receiving side checks if this is true, and performs error handling (re-request, etc.) if it is not.
(End of System Exclusive message Status = F7H)
16-bit Memory Image · ↓

There are two parameter unit operations: Individual Parameter Transfer and Individual Parameter Request.
For one session, in response to an IPR (Individual Parameter Request) from an external device, this Instrument returns an IPS (Individual Parameter Send) or the session is concluded when the external device or this Instrument spontaneously sends an IPS. If this Instrument received an IPS, the value of the applicable parameter is changed.
Depending on the function of a parameter, Individual Parameter Send may be used to issue a command to the Instrument and Individual Parameter Request may be used to check Instrument status information.
Data Receiver Data Sender Operation
IPR → Send Request (Optional)
← IPS Data Transfer
21.1.1 One-way and Handshake
In order to ensure maximum speed for bulk dumping of Parameter Sets, the data format is different from the data format used for Individual Parameter Send. Data is transferred as-is, using the Model's memory image.
Parameter Sets can be transferred by bulk dump using the message exchange types described below.
With the one-way mode, the sending device sends data and ends the session without regard to the response of the receiving device. This mode is best for one-way transfers from a sequencer or similar device. With the handshake mode, the sending device sends the data and then waits for a response from the receiving device before advancing to the next session. This is a high-speed mode in which there is no time wasted waiting.
See "Part VI Parameter Set List" for details about Instrument parameter sets.

Subsession "One subsession" refers to transfer of one parameter set. A subsession transfers one parameter set or a parameter set that has been divided into multiple packets for transfer, with EOD (End of Data) at the end to terminate the send. Division of a parameter set into multiple packets is used when the size of the parameter set is greater than a prescribed size. The packet number in the packet index field indicates the sequential position of a packet relative to the other packets. A single packet cannot be used to transfer multiple small parameter sets. A parameter set delimiter always must be transferred as a packet delimiter.
Session "One session" refers to a series of processes that occur for one user operation. One subsession or multiple subsessions make up a session. The sender sends EOS (End of Session) to end a session. Regardless of whether there is a single parameter set or multiple parameter sets being transferred, a bulk dump always takes the form of a session, never a subsession only.
A session starts with the receiving device sending a request using an OBR, or with the sending device sending OBS data. The session ends after transfer of all the data in the parameter set being transferred by the sending device is complete.
The transferred messages of a single parameter set cannot exceed 256 bytes. When 256 bytes are exceeded, data is divided into multiple packets of 256 bytes or less each and transferred at fixed intervals (20 msec).
A final EOD informs the receiving device when the session is ended.
Data Receiver (External Device)
Data Sender (This Instrument)
OBR → Send Request (Optional)
← OBS (20 msec or greater interval)
← OBS (20 msec or greater interval)
← OBS (20 msec or greater interval)
: :
← EOD End of Data
:
:
← EOS End of Session

A session starts with the receiving device sending a request using a HBR, or with the sending device sending HBS data. The sending device does not send the next packet until it receives an ACK from the receiving device. The maximum wait time of at least 2000 msec is reserved. Failure of a response to arrive within the wait time is treated as a timeout error, and data communication is terminated. The receiving devices returns ERR (error) when there is mismatch in the received data checksum or when an incompatible data format is discovered. When the sending device receives ERR (error) from the receiving device, it resends the last data sent. If an error repeats a number of times (three times or more for this Instrument), either the sending device or the receiving device sends an RJC to terminate the session. A session ends after the sending device transfers the volume of data determined by the number of parameter sets being transferred, and sends EOD and EOS in response to an ACK from the sending device.
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
← HBS Data Send
: :
← EOD End of Data
:
:
← EOS End of Session

The packed with the same packet number is resent when a checksum mismatch or incompatible data format error is detected.
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
← HBS Data Send 1
← HBS Data Send 2 (Retry 1)
← HBS Data Send 3 (Retry 2)
: :
← EOD End of Data
:
:
← EOS End of Session
Session terminates if ERR is detected a number of times.
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
← HBS Data Send
← HBS Data Send (Retry 1)
← HBS Data Send (Retry 2)
← HBS Data Send (Retry 3)
RJC → Session stopped

RJC is sent to terminate the session in case ACK cannot be recognized.
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
:
(Fixed amount of time elapses)
RJC ← Timeout error
The session can be canceled for any reason by sending an RJC. RJC can be sent by the sending device or the receiving device. The bulk dump session is terminated immediately upon receipt of an RJC.
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
← HBS Data Send
: :
RJC → Data Receive Canceled
Data Receiver Data Sender Operation
HBR → Send Request (Optional)
← HBS Data Send
← HBS Data Send
: :
← RJC Data Send Canceled
BSY is returned to the external device when OBS, OBR, HBS, or HBR is sent while the Instrument mode is not suitable to perform bulk dump, etc. After BSY is received, the external device should wait until the Instrument enters a mode in which the session is enabled.
Data Receiver Data Sender Operation
OBR → Send Request
← BSY Send Rejected

Data Receiver Data Sender Operation
← OBS Data Send
BSY → Receive Rejected
Data Receiver Data Sender Operation
HBR → Send Request
← BSY Send Rejected
Data Receiver Data Sender Operation
← HBS Data Send
BSY → Receive Rejected

This section explains the parameters that actually can be transferred by the Instrument.
These parameters make it possible for an external device to check the status of the Instrument and for an external device to command some operation of the Instrument.
This parameter is a container for system information.
Parameter ID R/W Block Size Array Min-Def-Max Description
00-20-7F
Ascii Character CTK-4000 ..."CTK-4000" CTK-5000 ..."CTK-5000" LK-270 "LK-270 " LK-205 "LK-205 " WK-200 "WK-200 " WK-500 "WK-500 " CDP-200R ..."CDP-200R" Ascii Character Ex. " 12345" General-purpose register for communication test
00-20-7F
R/W
00-00-FF

These are information acquisition and operation command parameters for this Instrument's Data Manager PC application.
Parameter ID R/W Block Size Array Min-Def-Max Description
Ps Category 0005 W 000000 7 01 00-00-7F Specifies the category ID of the parameter set that corresponds to an operation.
Ps Memory 0006 W ↑ 7 01 00-00-7F Specifies the memory ID of the parameter set that corresponds to an operation.
Ps Number 0007 W ↑ 14 01 0000-0001-3FFF Specifies the number of the parameter set that corresponds to an operation.
Ps Data Type 0008 R ↑ 8 01 00-00-FF This the data type of the parameter set in the specified category. Compatibility is provided between models with the same type.
Current Ps Existence 0009 R ↑ 1 01 00-00-01 Whether a parameter set exists in the specified category (0: No, 1: Yes).
Current Ps Protect 000A R ↑ 1 01 00-00-01 Protect status of a parameter set data in the specified category (0: Off, 1: On).
Current Ps Size 000B R ↑ 32 01 00000000-00000000-FFFFFFFF Size of a parameter set in the specified category/ number (bytes).
Current Sub Ps Size 000C R ↑ 32 01 00000000-00000000-FFFFFFFF Total size of a parameter sets under the specified category (bytes).
Current Ps Name 000D R ↑ 8 08 00-20-7F Name of a parameter set in the specified category (ASCII characters).
Max Ps Size 000E R ↑ 32 01 00000000-00000000-FFFFFFFF Maximum size of parameter sets in the specified category (bytes).
Max Ps Number 000F R ↑ 14 01 0000-0000-FFFF Maximum number parameter sets in the specified category (bytes).
Current Free Size 0010 R ↑ 32 01 00000000-00000000-FFFFFFFF Size of current parameter set free space in the specified category (bytes).
Max Free Size 0011 R ↑ 32 01 00000000-00000000-FFFFFFFF Maximum size of parameter free space in the specified category (bytes).
Delete Ps 0012 W ↑ 1 01 00-00-01 Deletes parameter sets in the specified category. Values are ignored.

The main function of patch parameters is to configure the settings of the sound source of a device.
These parameters configure Master Tuning settings.
Parameter ID R/W Block Size Array Min-Def-Max Description
Master Fine Tune Master Coarse Tune
7 7 01 01 00-40-7F 00-40-7F -100 - 0 - +99 (cent) -24 - 0 - +24 (semitone)
These parameters configure the Master settings of the mixer.
Parameter ID R/W Block Size Array Min-Def-Max Description
Master Volume 0002 R/W 000000 7 01 00-7F-7F 0 - 127
Part parameters configure the settings of each musical instrument part.
Parameter ID R/W Block Size Array Min-Def-Max Description
0...Off 1...On 0...Disable 1...Enable 0 - 16383 -100 - 0 - +99(cent) -24 - 0 - +24(semitone) 0 - 127 0 - 127 -64 - 0 - +63 0 - 127 0 - 127 0 - 24
↑
Tone Num Fine Tune Coarse Tune Volume Acmp Volume Pan Cho Send Rev Send Bend Range
006A 006B 006C 006D 006E 006F 0070 0071 0072
R/W
14 7
01
0000-0000-3FFF 00-40-7F 28-40-58 00-64-7F 00-7F-7F 00-40-7F 00-00-7F 00-28-7F 00-02-18

Scale memory parameters store scale memory data.
Parameter ID R/W Block Size Array Min-Def-Max Description
00-80-FF
-128 - 0 - +127 Array : Note 0 C 1 C# 2 D 3 D# 4 E 5 F 6 F# 7 G 8 G# 9 A 10...A# 11...B 0 Relative 1 Absolute
26 Song Parameter
The song parameter stores song data directory information.
Parameter ID R/W Block Size Array Min-Def-Max Description
7 32 08 01 20-20-7F 00000000-00000000-00FFFFFF Ascii Character 0 - 0xFFFFFFFF
The rhythm parameter stores rhythm directory information.
Parameter ID R/W Block Size Array Min-Def-Max Description
7 32 08 01 20-20-7F 00000000-00000000-00FFFFFF Ascii Character 0 - 0xFFFFFFFF
The sequence parameter stores recorder song directory information.
Parameter ID R/W Block Size Array Min-Def-Max Description
Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF
The lesson rec parameter stores recorder song (play-along) directory information.
Parameter ID R/W Block Size Array Min-Def-Max Description
Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF

The registration parameter stores registration data directory information.
Parameter ID R/W Block Size Array Min-Def-Max Description
Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF
There is no parameter for storing all data directory information.

This section explains actually how parameter sets can be transferred by the Instrument with bulk dump.
Parameter Set Category cat mem pset
Tone 03H 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 0007H (Drum Sampling Tone 0 - 2)
Drum 06H 00H 0000H - 0002H (Drum Sampling Tone 0 - 2)
Inst 0DH 00H 0000H - 07FH (Drum Sampling Tone 0 / Inst 0 - 127) 0080H - 0FFH (Drum Sampling Tone 1 / Inst 0 - 127) 0100H - 17FH (Drum Sampling Tone 2 / Inst 0 - 127)
Wave Param 0EH 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 000CH (Drum Sampling Tone 0 / WaveParam 0 - 7) 000DH - 0014H (Drum Sampling Tone 1 / WaveParam 0 - 7) 0015H - 001CH (Drum Sampling Tone 2 / WaveParam 0 - 7)
Wave Data 0FH 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 000CH (Drum Sampling Tone 0 / WaveParam 0 - 7) 000DH - 0014H (Drum Sampling Tone 1 / WaveParam 0 - 7) 0015H - 001CH (Drum Sampling Tone 2 / WaveParam 0 - 7)
Scale Memory 12H 00H 0003H - 0006H (User 1 - 4)
All 1FH 00H 0000H - 003CH
Song 20H 00H 0000H - 0009H (SongBank Song 0 - 9)
Sequence 21H 00H 0000H - 0004H (Recorder Song 0 - 4)
Registration 22H 00H 0000H - 0007H (Bank 0 - 8)
Lesson Rec 23H 00H 0000H
Rhythm 24H 00H 0000H - 0009H (User Rhythm 0 - 9)
Field Contents

(MSB-LSB)
00H-00H -100
: :
: :
33.1 Off/On Setting Value Table
33.5 Reverb Time Setting Value Table
Transmit Value Receive Value Parameter
00H 00H - 3FH Off
7FH 40H - 7FH On
18H 2
24H 3
33.2 -64 - 0 - +63 Setting Value Table
30H 4
3CH 5
00H -64
48H 6
01H -63
54H 7
: :
40H 0
6CH 9
: :
7EH 62
7FH 63
33.6 Chorus Type Setting Value Table
33.3 Pan Setting Value Table
: :
: :

When a MIDI implementation data value is expressed in binary, the letter "B" (for "binary") is affixed at the end of the value. The table below shows the binary equivalents for the decimal values 0 through 127, which are often used for settings.
34 Value Notation
1 01H 00000001B
2 02H 00000010B
34.1 Hexadecimal Notation
3 03H 00000011B
MIDI implementation sometimes requires that data be expressed in hexadecimal format. Hexadecimal values are indicated by the letter "H" after the value. The hexadecimal equivalents of decimal values 10 through 15 are expressed as the letters A through F. The table below shows the hexadecimal equivalents for decimal values 0 through 127, which are often used in MIDI messages.
5 05H 00000101B
6 06H 00000110B
7 07H 00000111B
8 08H 00001000B
Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal 0 00H 32 20H 64 40H 96 60H 1 01H 33 21H 65 41H 97 61H 2 02H 34 22H 66 42H 98 62H 3 03H 35 23H 67 43H 99 63H 4 04H 36 24H 68 44H 100 64H 5 05H 37 25H 69 45H 101 65H 6 06H 38 26H 70 46H 102 66H 7 07H 39 27H 71 47H 103 67H 8 08H 40 28H 72 48H 104 68H 9 09H 41 29H 73 49H 105 69H 10 0AH 42 2AH 74 4AH 106 6AH 11 0BH 43 2BH 75 4BH 107 6BH 12 0CH 44 2CH 76 4CH 108 6CH 13 0DH 45 2DH 77 4DH 109 6DH 14 0EH 46 2EH 78 4EH 110 6EH 15 0FH 47 2FH 79 4FH 111 6FH 16 10H 48 30H 80 50H 112 70H 17 11H 49 31H 81 51H 113 71H 18 12H 50 32H 82 52H 114 72H 19 13H 51 33H 83 53H 115 73H 20 14H 52 34H 84 54H 116 74H 21 15H 53 35H 85 55H 117 75H 22 16H 54 36H 86 56H 118 76H 23 17H 55 37H 87 57H 119 77H 24 18H 56 38H 88 58H 120 78H 25 19H 57 39H 89 59H 121 79H 26 1AH 58 3AH 90 5AH 122 7AH 27 1BH 59 3BH 91 5BH 123 7BH 28 1CH 60 3CH 92 5CH 124 7CH 29 1DH 61 3DH 93 5DH 125 7DH 30 1EH 62 3EH 94 5EH 126 7EH 31 1FH 63 3FH 95 5FH 127 7FH
10 0AH 00001010B
11 0BH 00001011B
12 0CH 00001100B
13 0DH 00001101B
14 0EH 00001110B
15 0FH 00001111B
16 10H 00010000B
: :
126 7EH 01111110B
127 7FH 01111111B