EN
Casio logo
Official user manual

Casio CDP-200R

46 pages·338 KB·Music Mixer·PDF·ENDEFRITNLJA
Casio CDP-200R
Table of Contents 80 sections CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200R · MIDI Implementation · Contents · Part I MIDI Message Overview · … ShowHide
CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200Rp.1MIDI Implementationp.1Contentsp.1Part I MIDI Message Overviewp.1Part II Channel Messagep.1Part III System Messagesp.2Part IV Instrument-Specific System Exclusive Messagesp.2Part V Parameter Listp.3Part VI Parameter Set Listp.4Part VII Setting Values and Send/Receive Valuesp.4Part VIII MIDI Implementation Notationp.41 Product Configuration as a MIDI Devicep.51.1 System Sectionp.51.2 Performance Controller Sectionp.51.3 Sound Generator Sectionp.51.3.1 Sound Generator Common Blockp.51.3.2 Instrument Part Blockp.62 Timbre Type Specific Operationp.73 Conditions that Disable Message Send and Receivep.74 Receive Channelp.85 Send Channelp.86 Note Offp.87 Note Onp.88 Polyphonic Key Pressurep.99 Control Changep.99.1 Bank Select (00H,20H)p.99.2 Modulation (01H)p.109.3 Data Entry (06H,26H)p.109.4 Volume (07H)p.109.5 Pan (0AH)p.119.6 Expression (0BH)p.119.7 Hold1 (40H)p.119.8 Sostenuto (42H)p.129.9 Soft (43H)p.129.10 Reverb Send (5BH)p.129.11 Chorus Send (5DH)p.139.12 NRPN (62H,63H)p.139.13 RPN (64H,65H)p.139.13.1 Pitch Bend Sensitivityp.149.13.2 Fine Tunep.149.13.3 Coarse Tunep.149.13.4 Nullp.159.14 All Sound Off (78H)p.159.15 Reset All Controllers (79H)p.1510 Mode Messagep.1610.1 All Notes Off (7BH)p.1610.2 Omni Off (7CH)p.1610.3 Omni On (7DH)p.1610.4 Mono (7EH)p.1610.5 Poly (7FH)p.1711 Program Changep.1711.1 About the Timbre Typep.1712 Channel Aftertouchp.1813 Pitch Bendp.1814 Timing Clockp.1915 Startp.1916 Stopp.1917 Active Sensingp.1918 System Exclusive Messagep.2018.1 Universal Realtime System Exclusive Messagep.2018.1.1 Master Volumep.2018.1.2 Master Fine Tuningp.2018.1.3 Master Coarse Tuningp.2118.1.4 Reverb Parameterp.2118.1.5 Chorus Parameterp.2118.1.6 GM System Messagep.2218.1.7 GS Messagep.2318.2 Instrument-Specific System Exclusive Messagep.2319.1 Message Classificationsp.2419.2 Basic Message Structurep.2519.3 Format of Each Fieldp.2519.3.1 SX : System Exclusive Message Statusp.2519.3.2 MAN : Manufacturer's IDp.2519.3.3 MOD : Model IDp.2519.3.4 dev : MIDI Device ID 00H-7FHp.2619.3.5 act : Actionp.2619.3.6 cat : Categoryp.2819.3.7 mem : Memory Area IDp.2819.3.8 pset : Parameter Set Numberp.2819.3.9 blk : Block Numberp.29
Page 1 of the Casio CDP-200R user manual — Table of Contents
Page 1 · Contents
Contents

Contents

CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200Rp.1MIDI Implementationp.1Contentsp.1Part I MIDI Message Overviewp.1Part II Channel Messagep.1Part III System Messagesp.2Part IV Instrument-Specific System Exclusive Messagesp.2Part V Parameter Listp.3Part VI Parameter Set Listp.4Part VII Setting Values and Send/Receive Valuesp.4Part VIII MIDI Implementation Notationp.41 Product Configuration as a MIDI Devicep.51.1 System Sectionp.51.2 Performance Controller Sectionp.51.3 Sound Generator Sectionp.51.3.1 Sound Generator Common Blockp.51.3.2 Instrument Part Blockp.62 Timbre Type Specific Operationp.73 Conditions that Disable Message Send and Receivep.74 Receive Channelp.85 Send Channelp.86 Note Offp.87 Note Onp.88 Polyphonic Key Pressurep.99 Control Changep.99.1 Bank Select (00H,20H)p.99.2 Modulation (01H)p.109.3 Data Entry (06H,26H)p.109.4 Volume (07H)p.109.5 Pan (0AH)p.119.6 Expression (0BH)p.119.7 Hold1 (40H)p.119.8 Sostenuto (42H)p.129.9 Soft (43H)p.129.10 Reverb Send (5BH)p.129.11 Chorus Send (5DH)p.139.12 NRPN (62H,63H)p.139.13 RPN (64H,65H)p.139.13.1 Pitch Bend Sensitivityp.149.13.2 Fine Tunep.149.13.3 Coarse Tunep.149.13.4 Nullp.159.14 All Sound Off (78H)p.159.15 Reset All Controllers (79H)p.1510 Mode Messagep.1610.1 All Notes Off (7BH)p.1610.2 Omni Off (7CH)p.1610.3 Omni On (7DH)p.1610.4 Mono (7EH)p.1610.5 Poly (7FH)p.1711 Program Changep.1711.1 About the Timbre Typep.1712 Channel Aftertouchp.1813 Pitch Bendp.1814 Timing Clockp.1915 Startp.1916 Stopp.1917 Active Sensingp.1918 System Exclusive Messagep.2018.1 Universal Realtime System Exclusive Messagep.2018.1.1 Master Volumep.2018.1.2 Master Fine Tuningp.2018.1.3 Master Coarse Tuningp.2118.1.4 Reverb Parameterp.2118.1.5 Chorus Parameterp.2118.1.6 GM System Messagep.2218.1.7 GS Messagep.2318.2 Instrument-Specific System Exclusive Messagep.2319.1 Message Classificationsp.2419.2 Basic Message Structurep.2519.3 Format of Each Fieldp.2519.3.1 SX : System Exclusive Message Statusp.2519.3.2 MAN : Manufacturer's IDp.2519.3.3 MOD : Model IDp.2519.3.4 dev : MIDI Device ID 00H-7FHp.2619.3.5 act : Actionp.2619.3.6 cat : Categoryp.2819.3.7 mem : Memory Area IDp.2819.3.8 pset : Parameter Set Numberp.2819.3.9 blk : Block Numberp.29
Page 2 of the Casio CDP-200R user manual — Part IV Instrument-Specific System Exclusive Messages
Page 2 · click to enlarge
Page 2

9.13 RPN (64H,65H) 13 9.13.1 Pitch Bend Sensitivity 14 9.13.2 Fine Tune 14 9.13.3 Coarse Tune 14 9.13.4 Null 15 9.14 All Sound Off (78H) 15 9.15 Reset All Controllers (79H) 15

10 Mode Message 16 10.1 All Notes Off (7BH) 16 10.2 Omni Off (7CH) 16 10.3 Omni On (7DH) 16 10.4 Mono (7EH) 16 10.5 Poly (7FH) 17

11 Program Change 17 11.1 About the Timbre Type 17

12 Channel Aftertouch 18

13 Pitch Bend 18

Part III System Messages

14 TimingClock 19

15 Start 19

16 Stop 19

17 Active Sensing 19

18 System Exclusive Message 20 18.1 Universal Realtime System Exclusive Message 20 18.1.1 Master Volume 20 18.1.2 Master Fine Tuning 20 18.1.3 Master Coarse Tuning 21 18.1.4 Reverb Parameter 21 18.1.5 Chorus Parameter 21 18.1.6 GM System Message 22 18.1.7 GS Message 23 18.2 Instrument-Specific System Exclusive Message 23

Part IV Instrument-Specific System Exclusive Messages

19 Format 24 19.1 Message Classifications 24 19.2 Basic Message Structure 25

Page 3 of the Casio CDP-200R user manual — Part V Parameter List
Page 3 · click to enlarge
Page 3

19.3 Format of Each Field 25 19.3.1 SX : System Exclusive Message Status 25 19.3.2 MAN : Manufacturer's ID 25 19.3.3 MOD : Model ID 25 19.3.4 dev: MIDI Device ID 00H-7FH 26 19.3.5 act : Action 26 19.3.6 cat : Category 28 19.3.7 mem : Memory Area ID 28 19.3.8 pset : Parameter Set Number 28 19.3.9 blk : Block Number 29 19.3.10 pkt : Packet Number 29 19.3.11 prm : Parameter ID 29 19.3.12 idx : Data Index Number 29 19.3.13 len : Data Length 30 19.3.14 data : Parameter Data 30 19.3.15 Single Parameter Data Size Limit 30 19.3.16 img : Parameter Set Image 31 19.3.17 sum : Check Sum 31 19.3.18 EOX : End of System Exclusive Message 31

20 Individual Parameter Operations 32

21 Parameter Set Transfer 32 21.1 Communication Modes 32 21.1.1 One-way and Handshake 32 21.1.2 Session and Subsession 33 21.2 One-way Mode Communication Flow 33 21.3 Handshake Mode Communication Flow 34

Part V Parameter List

22 Using the Parameter List 38

23 System Parameters 38 23.1 System Information Parameter 38 23.2 Data Management Parameter 39

24 Patch Parameters 40 24.1 Master Tune Parameter 40 24.2 Master Mixer Parameter 40 24.3 Part Parameter 40

25 Scale Memory Parameter 41

26 Song Parameter 41

27 Rhythm Parameter 41

28 Sequence Parameter 41

29 Lesson Rec Parameter 41

30 Registration Parameter 42

Page 4 of the Casio CDP-200R user manual — Part VIII MIDI Implementation Notation
Page 4 · click to enlarge
Page 4

31 All Data Parameter 42

Part VI Parameter Set List

32 Parameter Set Table 43

Part VII Setting Values and Send/Receive Values

33 Setting Value Tables 44 33.1 Off/On Setting Value Table 44 33.2 -64 - 0 - +63 Setting Value Table 44 33.3 Pan Setting Value Table 44 33.4 -100 - 0 - +99 Setting Value Table 44 33.5 Reverb Time Setting Value Table 44 33.6 Chorus Type Setting Value Table 44

Part VIII MIDI Implementation Notation

34 Value Notation 45 34.1 Hexadecimal Notation 45 34.2 Binary Notation 45

Page 5 of the Casio CDP-200R user manual — 1.3.1 Sound Generator Common Block
Page 5 · click to enlarge
Page 5

Part I MIDI Message Overview

1 Product Configuration as a MIDI Device

In terms of a MIDI device, this Instrument consists of a System Section, Performance Controller Section, and Sound Generator Section. Each of these sections can send and receive specific MIDI Messages in accordance with its function.

1.1 System Section

The System Section manages the Instrument status and user data. A communication method known as a "bulk dump" is supported, which allows two-way transfer of user data between the Instrument and a computer.

1.2 Performance Controller Section

The Performance Controller Section performs keyboard play and controller operations, and generates performance messages in accordance with auto play, etc. Basically, generated performance messages are sent to external destinations while also being transmitted to the Sound Generator Section. The channel number of the sent channel message is in accordance with Instrument's instrument part number.

MIDI Output Performance Information The following describes the performance information that is output and is not output as MIDI signals.

  • Output performance

– Keyboard play by the performer

  • Non-output performance

1.3 Sound Generator Section

The Sound Generator Section consists of a channel-independent common block and an independent instrument part specific to each channel. Mainly it receives performance information and sound source setting information.

1.3.1 Sound Generator Common Block

The common block consists of system effects, mixer master control, etc. These can be controlled by system exclusive messages that are basically exclusive to this particular instrument, but several parameters also can be controlled by general universal system exclusive messages.

Show 6 more labels / short text on this page
– Auto accompaniment · – Recorder playback · – Demo performance · – Song playback · – Lesson function · – Music Challenge
Page 6 of the Casio CDP-200R user manual — 1.3.2 Instrument Part Block
Page 6 · click to enlarge
Page 6

1.3.2 Instrument Part Block

The instrument parts of the sound generator can be operated or their settings can be changed with Instrument-specific system exclusive messages and channel messages. The 32 instrument parts of this Instrument are divided between Group A and Group B, each of which has 16 instrument parts. Only Group B can be controlled by external channel messages. As shown in the following table, there is a fixed relationship between channel message receive channel numbers and instrument parts.

NumberNameChannelAssigned Function 00A011Keyboard (Main) 01A022Keyboard (Layered) 02A033Keyboard (Split) 03A044Keyboard/Recorder (Harmonize) 04A055Sampling Phrase 05A066Guide Sound 06A077Guide Voice 07A088Metronome 08A099Auto Accompaniment (Percussion) 09A1010Auto Accompaniment (Drum) 10A1111Auto Accompaniment (Bass) 11A1212Auto Accompaniment (Chord 1) 12A1313Auto Accompaniment (Chord 2) 13A1414Auto Accompaniment (Chord 3) 14A1515Auto Accompaniment (Chord 4) 15A1616Auto Accompaniment (Chord 5) 16B011MIDI/Auto Performance Functions/Recorder (Keyboard Playback Main) 17B022MIDI/Auto Performance Functions/Recorder (Keyboard Playback Layered) 18B033MIDI/Auto Performance Functions/Recorder (Keyboard Playback Split) 19B044MIDI/Auto Performance Functions/Recorder (Solo 1) 20B055MIDI/Auto Performance Functions/Recorder (Solo 2) 21B066MIDI/Auto Performance Functions/Recorder (Solo 3) 22B077MIDI/Auto Performance Functions/Recorder (Solo 4) 23B088MIDI/Auto Performance Functions/Recorder (Solo 5) 24B099MIDI/Auto Performance Functions 25B1010MIDI/Auto Performance Functions 26B1111MIDI/Auto Performance Functions 27B1212MIDI/Auto Performance Functions 28B1313MIDI/Auto Performance Functions 29B1414MIDI/Auto Performance Functions 30B1515MIDI/Auto Performance Functions 31B1616MIDI/Auto Performance Functions
Page 7 of the Casio CDP-200R user manual — 3 Conditions that Disable Message Send and Receive
Page 7 · click to enlarge
Page 7

2 Timbre Type Specific Operation

The sound source operation performed for a received message depends on the current Timbre Type value (see "11.1 About the Timbre Type), which is the operation mode of each sound generator instrument part. For details, see the explanation for each message.

3 Conditions that Disable Message Send and Receive

All MIDI message send and receive is temporarily disabled while any one of the following processes is in progress.

  • SD memory card operation in progress Applicable Models: CTK-5000, LK-270, LK-205, WK-500, CDP-200R
  • Recorder recording in progress
  • Sampling operation in progress
Page 8 of the Casio CDP-200R user manual — 7 Note On
Page 8 · click to enlarge
Page 8

Part II Channel Message

4 Receive Channel

The channel number of the channel message received by each part is shown in the table under "1.3.2 Instrument Part Block".

5 Send Channel

Basically, the MIDI channel of the channel message sent when the Instrument is played coincides with the MIDI channel of the part being played. Note, however, that the MIDI channel of the performance information that corresponds to the keyboard main part is the Keyboard Channel setting value.

6 Note Off

Message Format:8nH kkH vvH 9nH kkH 00H (receive only) n:MIDI Channel Number kk:Key Number vv:Velocity Send40H ReceiveIgnored

Send Sent when something is played on the keyboard or when auto accompaniment is used. For keyboard play, the key number range is changed in accordance with the octave shift function.

Receive Received by Instrument parts corresponding to MIDI. The velocity value is ignored. A part that is turned off by the Part Enable Parameter value explained under "24.3 Part Parameter" is not received.

7 Note On

Message Format:9nH kkH vvH n:MIDI Channel Number kk:Key Number vv:Velocity

Send Sent when something is played on the keyboard. The key number range is changed in accordance with the octave shift function.

Receive Received by Instrument parts corresponding to MIDI. The velocity value is ignored. A part that is turned off by the Part Enable Parameter value explained under "24.3 Part Parameter" is not received.

Page 9 of the Casio CDP-200R user manual — 9.1 Bank Select (00H,20H)
Page 9 · click to enlarge
Page 9

8 Polyphonic Key Pressure

Message Format:AnH kkH vvH n:MIDI Channel Number kk:Key Number vv:Pressure Value

Send This message is not sent by this Instrument.

Receive This message is not received by this Instrument.

9 Control Change

Message Format:BnH ccH vvH n:MIDI Channel Number cc:Control Number vv:Value

Send Sent when the Instrument's pedal is operated or when Instrument settings are changed.

Receive Receipt changes the pedal and other performance conditions, and Instrument settings.

9.1 Bank Select (00H,20H)

Message Format:BnH 00H mmH (MSB) BnH 20H llH (LSB) n:MIDI Channel Number mm:MSB Value (Note1) ll:LSB Value Send00H ReceiveIgnored

Send Sent when a tone is selected. The LSB value is always 00H.

Receive Receipt causes a change in the tone bank number stored in Instrument memory, but the tone is not actually changed until a Program Change message is received. For details, see "11 Program Change". The LSB value is ignored.

Page 10 of the Casio CDP-200R user manual — 9.4 Volume (07H)
Page 10 · click to enlarge
Page 10

9.2 Modulation (01H)

Message Format:BnH 01H vvH n:MIDI Channel Number vv:Value

Send This message is not sent by this Instrument.

Receive Receipt adds, to the tone being sounded, modulation of a depth specified by the value. In the case of a tone that already has modulation applied, receipt of this message increases the modulation depth. The modulation effect differs according to the tone being used.

9.3 Data Entry (06H,26H)

Message Format:BnH 06H mmH (MSB) BnH 26H llH (LSB) n:MIDI Channel Number mm:MSB Value ll:LSB Value

Send Sent when there is a change to the parameter assigned to RPN. This Instrument does not have a parameter that corresponds to NRPN.

Receive Receipt changes the parameter assigned to RPN. This Instrument does not have a parameter that corresponds to NRPN.

9.4 Volume (07H)

Message Format:BnH 07H vvH n:MIDI Channel Number vv:Value

Send Sent when auto accompaniment is used.

Receive Receipt changes the volume of the corresponding part.

Page 11 of the Casio CDP-200R user manual — 9.7 Hold1 (40H)
Page 11 · click to enlarge
Page 11

9.5 Pan (0AH)

Message Format:BnH 0AH vvH n:MIDI Channel Number vv:Value (Note1)

Send Sent when auto accompaniment is used.

Receive Receipt changes the pan setting of the corresponding part.

9.6 Expression (0BH)

Message Format:BnH 0BH vvH n:MIDI Channel Number vv:Value

Send Sent when auto accompaniment is used.

Receive Receipt changes the Expression value.

9.7 Hold1 (40H)

Message Format:BnH 40H vvH n:MIDI Channel Number vv:Value (Note1)

Send Sent when a pedal that has a sustain (damper) function is operated.

Receive Receipt performs an operation equivalent to a sustain pedal operation.

Page 12 of the Casio CDP-200R user manual — 9.10 Reverb Send (5BH)
Page 12 · click to enlarge
Page 12

Timbre Type Specific Operation This operation differs in accordance with the Timbre Type (see "11.1 About the Timbre Type") setting.

  • Timbre Type: Melody Sustain off/on control is performed in accordance with the value of the received message.
  • Timbre Type: Drum The received message does not affect sound source operation.

9.8 Sostenuto (42H)

Message Format:BnH 42H vvH n:MIDI Channel Number vv:Value (Note1)

Send Sent when a pedal that has a sostenuto function is operated.

Receive Receipt performs an operation equivalent to a sostenuto pedal operation.

9.9 Soft (43H)

Message Format:BnH 43H vvH n:MIDI Channel Number vv:Value (Note1)

Send Sent when a pedal that has a soft function is operated.

Receive Receipt performs an operation equivalent to a soft pedal operation.

9.10 Reverb Send (5BH)

Message Format:BnH 5BH vvH n:MIDI Channel Number vv:Value
Page 13 of the Casio CDP-200R user manual — 9.13 RPN (64H,65H)
Page 13 · click to enlarge
Page 13

Send Sent when auto accompaniment is used.

Receive Changes Reverb Send.

9.11 Chorus Send (5DH)

Message FormatBnH 5DH vvH

n: MIDI Channel Number

vvValue (Note1)

Send Sent when auto accompaniment is used and when a Chorus on/off operation is performed.

Receive Changes Chorus Send.

9.12 NRPN (62H,63H)

Message FormatBnH 62H llH (LSB) BnH 63H mmH (MSB)

n: MIDI Channel Number

llLSB Value
mmMSB Value

Send This message is not sent by this Instrument.

Receive This Instrument does not have a corresponding NRPN message.

9.13 RPN (64H,65H)

Message FormatBnH 64H llH (LSB) BnH 65H mmH (MSB)

n: MIDI Channel Number

11. LSB Value
mmMSB Value
Page 14 of the Casio CDP-200R user manual — 9.13.3 Coarse Tune
Page 14 · click to enlarge
Page 14

9.13.1 Pitch Bend Sensitivity

Message FormatBnH 64H 00H BnH 65H 00H BnH 06H mmH BnH 26H llH

n: MIDI Channel Number

mmMSB Value 0 - 12
llLSB Value

Send Sent when the Bend Range is changed on the CTK-5000, WK-500, or CDP-200R.

Receive Receipt changes Bend Range.

9.13.2 Fine Tune

Message FormatBnH 64H 01H BnH 65H 00H BnH 06H mmH BnH 26H llH

n: MIDI Channel Number

mmMSB Value
llLSB Value

Send This message is not sent by this Instrument.

Receive Receipt changes Channel Fine Tune.

9.13.3 Coarse Tune

Message FormatBnH 64H 02H BnH 65H 00H BnH 06H mmH BnH 26H llH

n: MIDI Channel Number

mmMSB Value
llLSB Value

Send 00H · Receive Ignored

Page 15 of the Casio CDP-200R user manual — 9.15 Reset All Controllers (79H)
Page 15 · click to enlarge
Page 15

Send This message is not sent by this Instrument.

Receive Receipt changes Channel Coarse Tune. Does not affect sound source operation when the Timbre Type is Drum.

9.13.4 Null

Message FormatBnH 64H 7FH BnH 65H 7FH

n: MIDI Channel Number

Send Sent after the Bend Range is changed on the CTK-5000, WK-500, or CDP-200R.

Receive Receipt deselects RPN.

9.14 All Sound Off (78H)

Message FormatBnH 78H 00H

n: MIDI Channel Number

Send Sent when Local is set to OFF on the Instrument.

Receive Receipt stops all voices that are sounding.

9.15 Reset All Controllers (79H)

Message FormatBnH 79H 00H

n: MIDI Channel Number

Send Sent when MIDI send related settings are changed on the Instrument.

Receive Receipt initializes each performance controller.

Page 16 of the Casio CDP-200R user manual — 10.4 Mono (7EH)
Page 16 · click to enlarge
Page 16

10 Mode Message

10.1 All Notes Off (7BH)

Message FormatBnH 7BH 00H

n: MIDI Channel Number

Send Sent when MIDI send related settings are changed on the Instrument, or when auto play is stopped, etc.

Receive Receipt of any of this message releases the currently sounding voice (same as releasing the keyboard key).

10.2 Omni Off (7CH)

Message FormatBnH 7CH 00H

n: MIDI Channel Number

Send This message is never sent.

Receive Receipt of this message performs the same operation as when All Notes Off is received.

10.3 Omni On (7DH)

Message FormatBnH 7DH 00H

n: MIDI Channel Number

Send This message is never sent.

Receive Receipt of this message performs the same operation as when All Notes Off is received.

10.4 Mono (7EH)

Message FormatBnH 7EH 00H

n: MIDI Channel Number

Send This message is never sent.

Receive Receipt of this message performs the same operation as when All Notes Off is received.

Page 17 of the Casio CDP-200R user manual — 11.1 About the Timbre Type
Page 17 · click to enlarge
Page 17

10.5 Poly (7FH)

Message FormatBnH 7FH 00H

n: MIDI Channel Number

Send This message is never sent.

Receive Receipt of this message performs the same operation as when All Notes Off is received.

11 Program Change

Message FormatCnH ppH

n: MIDI Channel Number

ppProgram Number (Note1)

Send Sent when a tone is selected.

Receive Receipt of this message changes the tone of the part that corresponds to the MIDI channel. The selected tone is determined by the program value of this message and the Bank Select message value received prior to this message. Also note that receipt of this message also may change the Timbre Type that corresponds to the selected tone. For more information, see "11.1 About the Timbre Type" below.

11.1 About the Timbre Type

Tones that are selected by each Instrument part have an attribute that depends on the sound source operation type. This attribute is called the "timbre type," which is one of the types described below.

  • Melody This timbre type optimizes for normal melody tones.
  • Drum This setting optimizes for drum sounds. The damper pedal does not function. The Hold1, Channel Coarse Tune, and Master Coarse Tune messages are ignored if they are received.
Page 18 of the Casio CDP-200R user manual — 13 Pitch Bend
Page 18 · click to enlarge
Page 18

12 Channel Aftertouch

Message FormatDnH vvH

n: MIDI Channel Number

vvValue

Send These messages are never sent.

Receive Receipt of this message adds modulation to the voice that is sounding. The modulation effect differs according to the tone being used.

13 Pitch Bend

Message FormatEnH llH mmH

n: MIDI Channel Number

llValue LSB
mmValue MSB

Send Sent when a pitch bender operation is performed on the CTK-5000, WK-500, or CDP-200R.

Receive Receipt changes the pitch of the currently sounding note. The range of the pitch change depends on the Bend Range value setting.

Page 19 of the Casio CDP-200R user manual — 17 Active Sensing
Page 19 · click to enlarge
Page 19

Part III System Messages

14 Timing Clock

Message FormatF8H

Send Sent when auto accompaniment is used.

Receive This message is not received by this Instrument.

15 Start

Message FormatFAH

Send Sent when auto accompaniment is used.

Receive This message is not received by this Instrument.

16 Stop

Message FormatFCH

Send Sent when auto accompaniment is used.

Receive This message is not received by this Instrument.

17 Active Sensing

Message FormatFEH

Send This message is never sent.

Page 20 of the Casio CDP-200R user manual — 18.1.2 Master Fine Tuning
Page 20 · click to enlarge
Page 20

Receive Once this message is received, the Active Sensing mode is entered. If no MIDI message is received for a specified amount of time, voices being sounded by the Instrument's sound source are released, the controller is reset, and the Active Sensing mode is exited.

18 System Exclusive Message

Message FormatF0H....F7H

The Instrument sends and receives standard universal system exclusive messages, and system exclusive messages that have Instrument-specific formats.

18.1 Universal Realtime System Exclusive Message

Message FormatF0H 7FH....F7H

18.1.1 Master Volume

Message FormatF0H 7FH 7FH 04H 01H llH mmH F7H
llLSB Value
mmMSB Value

Send This message is never sent.

Receive Receipt changes the Master Volume parameter. Note that the Master Volume parameter cannot be changed with an Instrument operation.

18.1.2 Master Fine Tuning

Message FormatF0H 7FH 7FH 04H 03H llH mmH F7H
mmMSB Value(Note1)

Send This message is sent when the tuning setting is changed.

Receive Receipt changes the tuning setting.

Page 21 of the Casio CDP-200R user manual — 18.1.5 Chorus Parameter
Page 21 · click to enlarge
Page 21

18.1.3 Master Coarse Tuning

Message FormatF0H 7FH 7FH 04H 04H 00H mmH F7H
llLSB Value
mmMSB Value

Send Sent when Transpose is changed.

Receive Receipt changes the Transpose parameter. Does not affect sound source operation when the Timbre Type is Drum.

18.1.4 Reverb Parameter

Message FormatF0H 7FH 7FH 04H 05H 01H 01H 01H 01H 01H ppH vvH F7H
ppParameter
vvValue
Message FormatF0H 7FH 7FH 04H 05H 01H 01H 01H 01H 01H 01H vvH F7H
vvValue (Note1)

Send Sent when the Reverb duration is changed.

Receive Receipt changes the Reverb duration.

18.1.5 Chorus Parameter

Message FormatF0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H ppH vvH F7H
ppParameter
vvValue
Message FormatF0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H 00H vvH F7H
vvValue (Note1)

Time Format · Type Format

Page 22 of the Casio CDP-200R user manual — 18.1.6 GM System Message
Page 22 · click to enlarge
Page 22

Send This message is sent when the System Chorus Type setting is changed.

Receive Receipt changes the System Chorus Type parameter.

Message FormatF0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H 01H vvH F7H
vvValue (Note1)

Send This message is never sent.

Receive Receipt changes the System Chorus Rate parameter.

18.1.6 GM System Message

GM System On Format

Message FormatF0H 7EH 7FH 09H 01H F7H

Send This message is never sent.

Receive Receipt puts the sound source into a GM sound source mode.

GM System Off Format

Message FormatF0H 7EH 7FH 09H 02H F7H

Send This message is never sent.

Receive Receipt changes the sound source setting to the Instrument presetting.

GM2 System On Format

Message FormatF0H 7EH 7FH 09H 03H F7H

Send This message is never sent.

Receive Though the Instrument does not support GM2, receipt of the GM2 System On message has the same result as receipt of the GM System On message.

Rate Format

Page 23 of the Casio CDP-200R user manual — 18.2 Instrument-Specific System Exclusive Message
Page 23 · click to enlarge
Page 23

18.1.7 GS Message

Message FormatF0H 41H ddH 42H 12H 40H 00H 7FH 00H 41H F7H

Send This message is never sent.

Receive Receipt performs the same operation as when the GM System On message is received.

18.2 Instrument-Specific System Exclusive Message

Message FormatF0H 44H 16H 01H....F7H

This message can be used to send the Instrument memory status, for two-way transfer of special operation commands and user data, to perform sound source parameter operations, etc.

For more information, see "Part IV Instrument-Specific System Exclusive Messages".

Page 24 of the Casio CDP-200R user manual — 19.1 Message Classifications
Page 24 · click to enlarge
Page 24

Part IV Instrument-Specific System Exclusive Messages

This section explains the format of the Instrument-specific System Exclusive Messages. See "Part V Parameter List" and "Part VI Parameter Set List" for information about how parameter sets actually are transferred.

19.1 Message Classifications

Basically, the operation that corresponds to Instrument-specific system exclusive messages is parameter data transfer. The following operations can be performed from an external device using this parameter transfer message.

  • Modification of an individual Instrument parameter
  • Batch modification of a particular Instrument parameter set
  • Import of an individual Instrument parameter value
  • Batch import of a particular Instrument parameter set

In addition to parameters being used as device setting values, some parameters act as commands when received by the Instrument and as device status information when sent from the Instrument. The following table shows the parameter category for each type of transfer.

Function Section Parameter Category Description

System System Commands to the Instrument, Instrument stats

All All user data

Lesson Rec Recorder Song (Play-Along)

Scale Memory User Scale Memory

Sound Generator Patch Sound source common settings (system effects, master settings, etc.) Instrument part settings (tone selection, mixer channel setting, tuning, etc.)

Tone Sampled sound (melody/drum) selected by the user

Drum Sampled sound (drum) referenced from "Tone" category parameters

Instrument Individual instrument setting referenced from "Drum" category parameters

Wave Parameter Sampled sound Wave setting

Wave Data Waveform actual data referenced from "Wave Parameter" category parameters

Show 4 more labels / short text on this page
Song User Song · Sequence Recorder Song · Registration Registration · Rhythm User Rhythm
Page 25 of the Casio CDP-200R user manual — 19.3.3 MOD : Model ID
Page 25 · click to enlarge
Page 25

19.2 Basic Message Structure

Instrument-specific system exclusive message operation can be broadly divided between two methods: Individual Parameter Transfer (single parameter send/receive) and Bulk Parameter Set Transfer (batch parameter send/receive). Each method includes a number of different messages. The field in the SysEx message that specifies the message type is the action (act) field. The format of the "body" part of the message depends on the "act" value.

The table below shows the body format for each action of Instrument-specific system exclusive messages. An actual message consists of the items indicated by "Y", from left to right.

act SX MAN MOD dev act body (Depends on act) EOX

cat mem pset blk pkt prm idx len data img sum

NOP Y - Y

IPR Y - Y Y Y - - - Y

IPS Y - Y - - Y

OBR Y - Y

OBS Y - Y - - Y - Y Y Y

HBR Y - Y

HBS Y - Y - - Y - Y Y Y

ACK Y - Y

BSY - Y

RJC Y - Y

EOD Y - Y

EOS Y - Y

ERR Y - Y

19.3 Format of Each Field

19.3.1 SX : System Exclusive Message Status

Format11110000B

System Exclusive message Status = F0H

19.3.2 MAN : Manufacturer's ID

Format01000100B

Manufacturer's ID = 44H (CASIO)

19.3.3 MOD : Model ID

Format00010101B (MSB) 00000001B (LSB)

The Model ID of the series to which the Instrument belongs is shown by two consecutive bytes (MSB, LSB). (CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200R Model ID MSB = 16H, LSB = 01H)

Page 26 of the Casio CDP-200R user manual — 19.3.5 act : Action
Page 26 · click to enlarge
Page 26

19.3.4 dev : MIDI Device ID 00H-7FH

Format0dddddddB

The contents of this field in a received message are compared with the Model's MIDI Device ID, and receipt of the incoming message is allowed only when the two IDs match. When a message containing 7FH is received, receipt of the message is always allowed, regardless of the Instrument's ID setting. Note, however, that the Instrument does not have a specific Device ID, so use only 7FH for send and receive.

19.3.5 act : Action

Format0aaaaaaaB

aaaaaaaB = Action This field indicates the operation of the Instrument-specific System Exclusive Message.

00H NOP No Operation

01H IPR Individual Parameter Request

02H IPS Individual Parameter Send

03H OBR Oneway Bulk Parameter Set Request

04H OBS Oneway Bulk Parameter Set Send

05H HBR Handshake Bulk Parameter Set Request

06H HBS Handshake Bulk Parameter Set Send

0DH EOD End of Data

0EH EOS End of Session

NOP: No Operation No operation is performed when this action is received.

IPR: Individual Parameter Request Indicates an individual parameter value send request message. When the Instrument receives this action, it uses an IPS message to return the specified parameter value.

IPS: Individual Parameter Send Indicates an individual parameter value send message. When the Instrument receives this action, it rewrites the value specified by the data field with the specified parameter value.

OBR: Oneway Bulk Parameter Set Request Indicates a send request message using parameter set image one-way mode. When the Instrument receives this action, it uses an OBS message to return the specified parameter set.

OBS: Oneway Bulk Parameter Set Send Indicates a parameter set image send message using one-way mode. The parameter set to be transferred is divided into multiple packets when it is greater than a prescribed size. At this time, packets are transferred at intervals of the prescribed time (20 msec) or greater.

HBR: Handshake Bulk Parameter Set Request Indicates a send request message using the parameter set image handshake mode. When the Instrument receives this action, it uses an HBS message to return the specified parameter set.

Show 5 more labels / short text on this page
aaaaaaaB Action Function · 0AH ACK Acknowledge · 0BH BSY Busy · 0CH RJC Reject · 0FH ERR Error
Page 27 of the Casio CDP-200R user manual — 19.3.4 dev : MIDI Device ID 00H-7FH
Page 27 · click to enlarge
Page 27

HBS: Handshake Bulk Parameter Set Send Indicates a parameter set image send message using handshake mode. The parameter set to be transferred is divided into multiple packets when it is greater than a prescribed size. The packets are transferred in accordance with handshake mode.

ACK: Acknowledge Indicates a message used by the receiver during parameter set handshake mode transfer to convey to the sender that it is ready for send of the next packet. The cat, mem, and pset fields indicate the value carried by the last received message.

BSY: Busy Indicates a message to convey to the requester that that the Instrument cannot send back data after a parameter set one- way mode or handshake mode send request is received. The cat, mem, and pset fields indicate the value carried by the last received message.

RJC: Reject Indicates a message to convey to the other side that an ongoing parameter set one-way mode or handshake mode send or receive session was interrupted. The cat, mem, and pset fields indicate the value carried by the last received message.

EOD: End of Data Indicates a message to convey to the receiver that a one-way mode or handshake mode serial packet transfer for sending a sub-session (one parameter set) is complete. The cat, mem, and pset fields indicate the value carried by the last received message.

EOS: End of Session Indicates a message to convey to the receiver that a one-way mode or handshake mode serial parameter set transfer session send, which was launched by some operation, is complete. The cat, mem, and pset fields indicate the value carried by the last received message.

ERR: Error Indicates a message to convey to the sender that the checksum or message format of the previous packet was not correct when receiving a parameter set with handshake mode. The cat, mem, and pset fields indicate the value carried by the last received message.

Page 28 of the Casio CDP-200R user manual — 19.3.8 pset : Parameter Set Number
Page 28 · click to enlarge
Page 28

19.3.6 cat : Category

Format0cccccccB

0cccccccB = Category (7bit) The category indicates the categories of data handled by the System Exclusive Message. The ID number (ID) of the Category is indicated on the left, while the communication operation (Action) is indicated on the right.

ID (c) Parameter Set Individual Parameter One Way Bulk Handshake Bulk

00H System A - -

02H Patch A - -

03H Tone A A A

06H Drum A A A

0DH Instrument A A A

0EH Wave Parameter A A A

0FH Wave Data F A A

12H Scale Memory A A A

1FH All F A A

20H Song F A A

21H Sequence F A A

22H Registration F A A

23H Lesson Rec F A A

24H Rhythm F A A

A.. Available (Also including when only some parameters are available.) F... File Information (Not the data itself. Name, size, and other file information only.) -... Not Available

19.3.7 mem : Memory Area ID

Format0mmmmmmmB

Specifies the memory area that is the object of the parameter transfer. The following are defined for this Instrument.

0 User area Read/write enabled

1 Preset area Read/write disabled

19.3.8 pset : Parameter Set Number

Format0nnnnnnnB (LSB) 0mmmmmmmB (MSB)

This field is a 2-byte (LSB, MSB) value indicating the number of the parameter set (mmmmmmmnnnnnnnB, Binary) being transferred.

Category Transfer · Mem Type Meaning

Page 29 of the Casio CDP-200R user manual — 19.3.12 idx : Data Index Number
Page 29 · click to enlarge
Page 29

19.3.9 blk : Block Number

The block number is a supplementary number that specifies which block parameter is to be accessed.

Format0iiiiiiiB (LSB) 0jjjjjjjB 0kkkkkkkB (MSB)

Block Bit Field Division When the parameter block has a multi-dimensional array structure, bit 21 of the block number is divided into prescribed bit fields based on the rules explained below.

  • Case 1 When an array has three or fewer nesting levels and the number of arrays in each dimension is 128 or less, they are assigned below the three 7-bit fields. Unused regions are filled will zeros.

Example: parameter [A][B][C] With a 3-dimensional array parameter that consists of A=8 (3 bits), B=5 (3 bits) and C=10 (4 bits), the block bit fields are allocated as: Block = 0000aaa 000bbb ccccccc (Binary).

  • Case 2 When Case 1 conditions are not satisfied, the minimal number of fields required for each number of arrays is reserved from the lower bit of the block. Unused regions are filled will zeros. (This case does not apply with this Instrument.)

Example 1: parameter [A][B][C][D] With a 4-dimensional array parameter that consists of A=3 (2 bits), B=4 (2 bits), C=3 (2 bits) and D=4 (2 bits) like the one shown above, the block bit fields are allocated as: Block = 0000000 00000a abbccdd (Binary).

Example 2: parameter [A][B] A=3 (2 bits), B=200 (8 bits) With a 2-dimensional array parameter like the one shown above, the block bit fields are allocated as: Block = 0000000 000aab bbbbbbb (Binary).

19.3.10 pkt : Packet Number

Format0iiiiiiiB (LSB) 0jjjjjjjB 0kkkkkkkB (MSB)

This is the divided packet number kkkkkkkjjjjjjjiiiiiiiB (Binary) for transferring a single parameter set.

19.3.11 prm : Parameter ID

Format0pppppppB (LSB) 0qqqqqqqB (MSB)

The Parameter ID indicates the parameter type. When transferring parameters (see "Part V Parameter List" below) individually (as opposed to bulk transfer), this field is used to identify the parameter being transferred by its parameter ID.

19.3.12 idx : Data Index Number

Format0iiiiiiiB (LSB) 0jjjjjjjB (MSB)

The data index number indicates the first array number of the array from which transfer starts.

Page 30 of the Casio CDP-200R user manual — 19.3.15 Single Parameter Data Size Limit
Page 30 · click to enlarge
Page 30

19.3.13 len : Data Length

Format0lllllllB (LSB) 0mmmmmmmB (MSB)

As shown below, the meaning of this field differs depending on whether an individual transfer or a bulk parameter set transfer is being performed.

Individual Parameter Transfer Data length indicates the length of the array being transferred minus 1 when the parameter contains a character string or other similar array structure.

Bulk Parameter Set Transfer Data length indicates the number of bytes of data included within a packet. When this value is zero, it means there is no actual data.

19.3.14 data : Parameter Data

Format0dddddddB (0eeeeeeeB) (0fffffffB) (0gggggggB) (0hhhhhhhB)

: :

Parameter data indicates the parameter value. Data that is the size of the number of arrays equivalent to len + 1 follows. For the structure of one data item, the length depends on the data bit width, as shown below.

dddddB + 1 Number of Data

1. 7 1
8. 14 2
15. 21 3
22. 28 4
29. 32 5

Each block of data is packed from the lowest order byte first. In the case of multiple-byte data, the lowest weighted bit is the LSB of the first "data" block, and the highest weighted bit is the MSB of the final "data" block. The following shows an example of how data would be divided for transfer in the case of 32-bit data.

7 6 5 4 3 2 1 0

data00 [bit06] [bit05] [bit04] [bit03] [bit02] [bit01] [bit00]
data10 [bit13] [bit12] [bit11] [bit10] [bit09] [bit08] [bit07]
data20 [bit20] [bit19] [bit18] [bit17] [bit16] [bit15] [bit14]
data30 [bit27] [bit26] [bit25] [bit24] [bit23] [bit22] [bit21]
data40 0 0 0 [bit31] [bit30] [bit29] [bit28]

19.3.15 Single Parameter Data Size Limit

With the Instrument's system exclusive message format, the size of a single message cannot exceed 256 bytes. The data size and the array size, however, can cause a packet to exceed 256 bytes when transferring a single parameter array. In this case, the IPS and IPR message data length and data index number values can be modified to enable division of a single parameter value into multiple messages so it can be sent that way.

Page 31 of the Casio CDP-200R user manual — 19.3.18 EOX : End of System Exclusive Message
Page 31 · click to enlarge
Page 31

19.3.16 img : Parameter Set Image

Format0dddddddB 0cccccccB 000000abB

For a bulk data transfer operation, the parameter set data to be transferred is read sequentially in 16-bit units starting from the top address. Read values are divided into 3-byte segments as shown below, and then sent in sequence.

The following is the conversion format, which is the same as the individual parameter 16-bit transfer detailed above.

MSBabccccccB
LSBcdddddddB
data00dddddddB
data10cccccccB
data2000000abB

If the length of the data being transferred is an odd number of bytes, the final bit field is filled in with zero.

Parameter Set Packet Division The maximum image size of the parameter set that can be sent with one packet is 128 bytes. When data that exceeds 128 bytes is transferred, data is always divided into 128-byte units, except for the final packet. Because of this, the data in received packets can be stored in an areas the size of [Parameter Set Start Address] + [Packet Number] × 128.

For bulk parameter set transfer, the 16-bit image is divided in 3-byte groups, so the img field length is the value produced by multiplying the len value (len + 1 when len is an odd number) by 3/2. Note, however, that a parameter set of 128 bytes or less can be sent using a single packet, and anything greater than 128 bytes is divided among multiple packets. This means that the maximum length "data" field is 128 × 3/2 = 192 bytes.

Only one parameter set can be transferred per session, and data from different parameter sets cannot be mixed within a single packet, even when sending multiple parameter sets. Different parameter sets are always divided into separate packets.

19.3.17 sum : Check Sum

Format0sssssssB

In this case, this "sum" field contains a value, which, when added to the total value of the "img" field, makes the lower seven bits 0. The receiving side checks if this is true, and performs error handling (re-request, etc.) if it is not.

19.3.18 EOX : End of System Exclusive Message

Format11110111B

(End of System Exclusive message Status = F7H)

16-bit Memory Image · ↓

Page 32 of the Casio CDP-200R user manual — 21.1 Communication Modes
Page 32 · click to enlarge
Page 32

20 Individual Parameter Operations

There are two parameter unit operations: Individual Parameter Transfer and Individual Parameter Request.

For one session, in response to an IPR (Individual Parameter Request) from an external device, this Instrument returns an IPS (Individual Parameter Send) or the session is concluded when the external device or this Instrument spontaneously sends an IPS. If this Instrument received an IPS, the value of the applicable parameter is changed.

Depending on the function of a parameter, Individual Parameter Send may be used to issue a command to the Instrument and Individual Parameter Request may be used to check Instrument status information.

Data Receiver Data Sender Operation

IPR → Send Request (Optional)

← IPS Data Transfer

21 Parameter Set Transfer

21.1 Communication Modes

21.1.1 One-way and Handshake

In order to ensure maximum speed for bulk dumping of Parameter Sets, the data format is different from the data format used for Individual Parameter Send. Data is transferred as-is, using the Model's memory image.

Parameter Sets can be transferred by bulk dump using the message exchange types described below.

  • One-way mode Parameter Set send/receive
  • One-way mode Parameter Set send request send/receive
  • Handshake mode Parameter Set send/receive
  • Handshake mode Parameter Set send request, receive rejected, error notification send/receive

With the one-way mode, the sending device sends data and ends the session without regard to the response of the receiving device. This mode is best for one-way transfers from a sequencer or similar device. With the handshake mode, the sending device sends the data and then waits for a response from the receiving device before advancing to the next session. This is a high-speed mode in which there is no time wasted waiting.

See "Part VI Parameter Set List" for details about Instrument parameter sets.

Page 33 of the Casio CDP-200R user manual — 21.2 One-way Mode Communication Flow
Page 33 · click to enlarge
Page 33

21.1.2 Session and Subsession

Subsession "One subsession" refers to transfer of one parameter set. A subsession transfers one parameter set or a parameter set that has been divided into multiple packets for transfer, with EOD (End of Data) at the end to terminate the send. Division of a parameter set into multiple packets is used when the size of the parameter set is greater than a prescribed size. The packet number in the packet index field indicates the sequential position of a packet relative to the other packets. A single packet cannot be used to transfer multiple small parameter sets. A parameter set delimiter always must be transferred as a packet delimiter.

Session "One session" refers to a series of processes that occur for one user operation. One subsession or multiple subsessions make up a session. The sender sends EOS (End of Session) to end a session. Regardless of whether there is a single parameter set or multiple parameter sets being transferred, a bulk dump always takes the form of a session, never a subsession only.

21.2 One-way Mode Communication Flow

A session starts with the receiving device sending a request using an OBR, or with the sending device sending OBS data. The session ends after transfer of all the data in the parameter set being transferred by the sending device is complete.

The transferred messages of a single parameter set cannot exceed 256 bytes. When 256 bytes are exceeded, data is divided into multiple packets of 256 bytes or less each and transferred at fixed intervals (20 msec).

A final EOD informs the receiving device when the session is ended.

Data Receiver (External Device)

Data Sender (This Instrument)

OBR → Send Request (Optional)

← OBS (20 msec or greater interval)

← OBS (20 msec or greater interval)

← OBS (20 msec or greater interval)

: :

← EOD End of Data

:

:

← EOS End of Session

Show 5 more labels / short text on this page
Operation · Data Transfer · Data Transfer · Data Transfer · Other subsessions
Page 34 of the Casio CDP-200R user manual — 21.3 Handshake Mode Communication Flow
Page 34 · click to enlarge
Page 34

21.3 Handshake Mode Communication Flow

A session starts with the receiving device sending a request using a HBR, or with the sending device sending HBS data. The sending device does not send the next packet until it receives an ACK from the receiving device. The maximum wait time of at least 2000 msec is reserved. Failure of a response to arrive within the wait time is treated as a timeout error, and data communication is terminated. The receiving devices returns ERR (error) when there is mismatch in the received data checksum or when an incompatible data format is discovered. When the sending device receives ERR (error) from the receiving device, it resends the last data sent. If an error repeats a number of times (three times or more for this Instrument), either the sending device or the receiving device sends an RJC to terminate the session. A session ends after the sending device transfers the volume of data determined by the number of parameter sets being transferred, and sends EOD and EOS in response to an ACK from the sending device.

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

← HBS Data Send

: :

← EOD End of Data

:

:

← EOS End of Session

Show 4 more labels / short text on this page
ACK → Acknowledge · ACK → Acknowledge · ACK → Acknowledge · Other subsessions
Page 35 of the Casio CDP-200R user manual — 19.3.9 blk : Block Number
Page 35 · click to enlarge
Page 35

The packed with the same packet number is resent when a checksum mismatch or incompatible data format error is detected.

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

← HBS Data Send 1

← HBS Data Send 2 (Retry 1)

← HBS Data Send 3 (Retry 2)

: :

← EOD End of Data

:

:

← EOS End of Session

Session terminates if ERR is detected a number of times.

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

← HBS Data Send

← HBS Data Send (Retry 1)

← HBS Data Send (Retry 2)

← HBS Data Send (Retry 3)

RJC → Session stopped

Show 14 more labels / short text on this page
ACK → Acknowledge · ERR → Error · ERR → Error · ACK → Acknowledge · ACK → Acknowledge · Other subsessions · ACK → Acknowledge · (Error generated) · ERR → Error · (Error generated) · ERR → Error · (Error generated) · ERR → Error · (Error generated)
Page 36 of the Casio CDP-200R user manual — 19.3.9 blk : Block Number
Page 36 · click to enlarge
Page 36

RJC is sent to terminate the session in case ACK cannot be recognized.

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

:

(Fixed amount of time elapses)

RJC ← Timeout error

The session can be canceled for any reason by sending an RJC. RJC can be sent by the sending device or the receiving device. The bulk dump session is terminated immediately upon receipt of an RJC.

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

← HBS Data Send

: :

RJC → Data Receive Canceled

Data Receiver Data Sender Operation

HBR → Send Request (Optional)

← HBS Data Send

← HBS Data Send

: :

← RJC Data Send Canceled

BSY is returned to the external device when OBS, OBR, HBS, or HBR is sent while the Instrument mode is not suitable to perform bulk dump, etc. After BSY is received, the external device should wait until the Instrument enters a mode in which the session is enabled.

Data Receiver Data Sender Operation

OBR → Send Request

← BSY Send Rejected

Show 5 more labels / short text on this page
ACK → Acknowledge · (Terminate operation) · ACK → Acknowledge · ACK → Acknowledge · (Terminate operation)
Page 37 of the Casio CDP-200R user manual — 19.3.9 blk : Block Number
Page 37 · click to enlarge
Page 37

Data Receiver Data Sender Operation

← OBS Data Send

BSY → Receive Rejected

Data Receiver Data Sender Operation

HBR → Send Request

← BSY Send Rejected

Data Receiver Data Sender Operation

← HBS Data Send

BSY → Receive Rejected

Page 38 of the Casio CDP-200R user manual — R
Page 38 · click to enlarge
Page 38

Part V Parameter List

This section explains the parameters that actually can be transferred by the Instrument.

22 Using the Parameter List

  • Parameter field Shows the parameter name.
  • ID field Shows the parameter ID as a hexadecimal number.
  • R/W field Shows "R" to indicate that an IPR (Individual Parameter Request) read operation (Read) is possible or "W" to indicate that an IPS (Individual Parameter Send) write operation is possible.
  • Block field Shows the bit field allocation of the block number. The bit field position is shown as a decimal format number.
  • Size field Shows the parameter bit width as a decimal format value.
  • Array field Shows the parameter array size as a hexadecimal value.
  • Min-Def-Max field Shows the minimum value, default value, and maximum value for parameter acquisition as a hexadecimal value.
  • Description field Explains the meaning of parameter values. Unless otherwise specified, setting values are all indicated in decimal format.

23 System Parameters

These parameters make it possible for an external device to check the status of the Instrument and for an external device to command some operation of the Instrument.

23.1 System Information Parameter

This parameter is a container for system information.

Parameter ID R/W Block Size Array Min-Def-Max Description

R

00-20-7F

Ascii Character CTK-4000 ..."CTK-4000" CTK-5000 ..."CTK-5000" LK-270 "LK-270 " LK-205 "LK-205 " WK-200 "WK-200 " WK-500 "WK-500 " CDP-200R ..."CDP-200R" Ascii Character Ex. " 12345" General-purpose register for communication test

R

00-20-7F

R/W

00-00-FF

Show 5 more labels / short text on this page
Model Name · Program Revision · ↑ · ↑ · General Register
Page 39 of the Casio CDP-200R user manual — 23.2 Data Management Parameter
Page 39 · click to enlarge
Page 39

23.2 Data Management Parameter

These are information acquisition and operation command parameters for this Instrument's Data Manager PC application.

Parameter ID R/W Block Size Array Min-Def-Max Description

Ps Category 0005 W 000000 7 01 00-00-7F Specifies the category ID of the parameter set that corresponds to an operation.

Ps Memory 0006 W ↑ 7 01 00-00-7F Specifies the memory ID of the parameter set that corresponds to an operation.

Ps Number 0007 W ↑ 14 01 0000-0001-3FFF Specifies the number of the parameter set that corresponds to an operation.

Ps Data Type 0008 R ↑ 8 01 00-00-FF This the data type of the parameter set in the specified category. Compatibility is provided between models with the same type.

Current Ps Existence 0009 R ↑ 1 01 00-00-01 Whether a parameter set exists in the specified category (0: No, 1: Yes).

Current Ps Protect 000A R ↑ 1 01 00-00-01 Protect status of a parameter set data in the specified category (0: Off, 1: On).

Current Ps Size 000B R ↑ 32 01 00000000-00000000-FFFFFFFF Size of a parameter set in the specified category/ number (bytes).

Current Sub Ps Size 000C R ↑ 32 01 00000000-00000000-FFFFFFFF Total size of a parameter sets under the specified category (bytes).

Current Ps Name 000D R ↑ 8 08 00-20-7F Name of a parameter set in the specified category (ASCII characters).

Max Ps Size 000E R ↑ 32 01 00000000-00000000-FFFFFFFF Maximum size of parameter sets in the specified category (bytes).

Max Ps Number 000F R ↑ 14 01 0000-0000-FFFF Maximum number parameter sets in the specified category (bytes).

Current Free Size 0010 R ↑ 32 01 00000000-00000000-FFFFFFFF Size of current parameter set free space in the specified category (bytes).

Max Free Size 0011 R ↑ 32 01 00000000-00000000-FFFFFFFF Maximum size of parameter free space in the specified category (bytes).

Delete Ps 0012 W ↑ 1 01 00-00-01 Deletes parameter sets in the specified category. Values are ignored.

Page 40 of the Casio CDP-200R user manual — R/W
Page 40 · click to enlarge
Page 40

24 Patch Parameters

The main function of patch parameters is to configure the settings of the sound source of a device.

24.1 Master Tune Parameter

These parameters configure Master Tuning settings.

Parameter ID R/W Block Size Array Min-Def-Max Description

Master Fine Tune Master Coarse Tune

0000 0001 R/W R/W

7 7 01 01 00-40-7F 00-40-7F -100 - 0 - +99 (cent) -24 - 0 - +24 (semitone)

24.2 Master Mixer Parameter

These parameters configure the Master settings of the mixer.

Parameter ID R/W Block Size Array Min-Def-Max Description

Master Volume 0002 R/W 000000 7 01 00-7F-7F 0 - 127

24.3 Part Parameter

Part parameters configure the settings of each musical instrument part.

Parameter ID R/W Block Size Array Min-Def-Max Description

R/W

4-0Part Number

0...Off 1...On 0...Disable 1...Enable 0 - 16383 -100 - 0 - +99(cent) -24 - 0 - +24(semitone) 0 - 127 0 - 127 -64 - 0 - +63 0 - 127 0 - 127 0 - 24

R/W

↑

Tone Num Fine Tune Coarse Tune Volume Acmp Volume Pan Cho Send Rev Send Bend Range

006A 006B 006C 006D 006E 006F 0070 0071 0072

R/W

14 7

01

0000-0000-3FFF 00-40-7F 28-40-58 00-64-7F 00-7F-7F 00-40-7F 00-00-7F 00-28-7F 00-02-18

Show 6 more labels / short text on this page
000000 ↑ · Part Enable · 00-01-01 · Scaletune Enable · ↑ · 00-01-01
Page 41 of the Casio CDP-200R user manual — 29 Lesson Rec Parameter
Page 41 · click to enlarge
Page 41

25 Scale Memory Parameter

Scale memory parameters store scale memory data.

Parameter ID R/W Block Size Array Min-Def-Max Description

R/W

00-80-FF

-128 - 0 - +127 Array : Note 0 C 1 C# 2 D 3 D# 4 E 5 F 6 F# 7 G 8 G# 9 A 10...A# 11...B 0 Relative 1 Absolute

R/W

26 Song Parameter

The song parameter stores song data directory information.

Parameter ID R/W Block Size Array Min-Def-Max Description

0000 0002 R R

7 32 08 01 20-20-7F 00000000-00000000-00FFFFFF Ascii Character 0 - 0xFFFFFFFF

27 Rhythm Parameter

The rhythm parameter stores rhythm directory information.

Parameter ID R/W Block Size Array Min-Def-Max Description

0000 0002 R R

7 32 08 01 20-20-7F 00000000-00000000-00FFFFFF Ascii Character 0 - 0xFFFFFFFF

28 Sequence Parameter

The sequence parameter stores recorder song directory information.

Parameter ID R/W Block Size Array Min-Def-Max Description

Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF

29 Lesson Rec Parameter

The lesson rec parameter stores recorder song (play-along) directory information.

Parameter ID R/W Block Size Array Min-Def-Max Description

Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF

Show 7 more labels / short text on this page
A Key Mode · ↑ · 00-00-01 · Name Size · 000000 ↑ · Name Size · 000000 ↑
Page 42 of the Casio CDP-200R user manual — 31 All Data Parameter
Page 42 · click to enlarge
Page 42

30 Registration Parameter

The registration parameter stores registration data directory information.

Parameter ID R/W Block Size Array Min-Def-Max Description

Size 0001 R 000000 32 01 00000000-00000000-00FFFFFF 0 - 0xFFFFFFFF

31 All Data Parameter

There is no parameter for storing all data directory information.

Page 43 of the Casio CDP-200R user manual — 32 Parameter Set Table
Page 43 · click to enlarge
Page 43

Part VI Parameter Set List

This section explains actually how parameter sets can be transferred by the Instrument with bulk dump.

32 Parameter Set Table

Parameter Set Category cat mem pset

Tone 03H 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 0007H (Drum Sampling Tone 0 - 2)

Drum 06H 00H 0000H - 0002H (Drum Sampling Tone 0 - 2)

Inst 0DH 00H 0000H - 07FH (Drum Sampling Tone 0 / Inst 0 - 127) 0080H - 0FFH (Drum Sampling Tone 1 / Inst 0 - 127) 0100H - 17FH (Drum Sampling Tone 2 / Inst 0 - 127)

Wave Param 0EH 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 000CH (Drum Sampling Tone 0 / WaveParam 0 - 7) 000DH - 0014H (Drum Sampling Tone 1 / WaveParam 0 - 7) 0015H - 001CH (Drum Sampling Tone 2 / WaveParam 0 - 7)

Wave Data 0FH 00H 0000H - 0004H (Melody Sampling Tone 0 - 4) 0005H - 000CH (Drum Sampling Tone 0 / WaveParam 0 - 7) 000DH - 0014H (Drum Sampling Tone 1 / WaveParam 0 - 7) 0015H - 001CH (Drum Sampling Tone 2 / WaveParam 0 - 7)

Scale Memory 12H 00H 0003H - 0006H (User 1 - 4)

All 1FH 00H 0000H - 003CH

Song 20H 00H 0000H - 0009H (SongBank Song 0 - 9)

Sequence 21H 00H 0000H - 0004H (Recorder Song 0 - 4)

Registration 22H 00H 0000H - 0007H (Bank 0 - 8)

Lesson Rec 23H 00H 0000H

Rhythm 24H 00H 0000H - 0009H (User Rhythm 0 - 9)

  • cat field Shows the category value.
  • mem field Shows the memory area ID value.
  • pset field Shows the parameter set number value. Applicable parameter set numbers are those in the user area where the top number is zero, and are not the same numbers as those displayed by the Instrument.

Field Contents

Page 44 of the Casio CDP-200R user manual — 72H 10
Page 44 · click to enlarge
Page 44

Part VII Setting Values and Send / Receive Values

33.4 -100 - 0 - +99 Setting Value Table

(MSB-LSB)

00H-00H -100

: :

40H-00H 0

: :

33 Setting Value Tables

7FH-7FH 99

33.1 Off/On Setting Value Table

33.5 Reverb Time Setting Value Table

Transmit Value Receive Value Parameter

00H 00H - 3FH Off

00H OFF

7FH 40H - 7FH On

0CH 1

18H 2

24H 3

33.2 -64 - 0 - +63 Setting Value Table

30H 4

3CH 5

00H -64

48H 6

01H -63

54H 7

: :

60H 8

40H 0

6CH 9

: :

72H 10

7EH 62

7FH 63

33.6 Chorus Type Setting Value Table

33.3 Pan Setting Value Table

: :

: :

Show 13 more labels / short text on this page
Transmit/Receive Value Parameter · Transmit/Receive Value Parameter · Transmit/Receive Value Parameter · Transmit/Receive Value Parameter · 00H Chorus Type1 · Transmit/Receive Value Parameter · 01H Chorus Type2 · 00H Left · 02H Chorus Type3 · 03H Chorus Type4 · 40H Center · 04H Chorus Type5 · 7FH Right
Page 45 of the Casio CDP-200R user manual — 125 7DH 01111101B
Page 45 · click to enlarge
Page 45

Part VIII MIDI Implementation Notation

34.2 Binary Notation

When a MIDI implementation data value is expressed in binary, the letter "B" (for "binary") is affixed at the end of the value. The table below shows the binary equivalents for the decimal values 0 through 127, which are often used for settings.

0 00H 00000000B

34 Value Notation

1 01H 00000001B

2 02H 00000010B

34.1 Hexadecimal Notation

3 03H 00000011B

MIDI implementation sometimes requires that data be expressed in hexadecimal format. Hexadecimal values are indicated by the letter "H" after the value. The hexadecimal equivalents of decimal values 10 through 15 are expressed as the letters A through F. The table below shows the hexadecimal equivalents for decimal values 0 through 127, which are often used in MIDI messages.

4 04H 00000100B

5 05H 00000101B

6 06H 00000110B

7 07H 00000111B

8 08H 00001000B

Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal 0 00H 32 20H 64 40H 96 60H 1 01H 33 21H 65 41H 97 61H 2 02H 34 22H 66 42H 98 62H 3 03H 35 23H 67 43H 99 63H 4 04H 36 24H 68 44H 100 64H 5 05H 37 25H 69 45H 101 65H 6 06H 38 26H 70 46H 102 66H 7 07H 39 27H 71 47H 103 67H 8 08H 40 28H 72 48H 104 68H 9 09H 41 29H 73 49H 105 69H 10 0AH 42 2AH 74 4AH 106 6AH 11 0BH 43 2BH 75 4BH 107 6BH 12 0CH 44 2CH 76 4CH 108 6CH 13 0DH 45 2DH 77 4DH 109 6DH 14 0EH 46 2EH 78 4EH 110 6EH 15 0FH 47 2FH 79 4FH 111 6FH 16 10H 48 30H 80 50H 112 70H 17 11H 49 31H 81 51H 113 71H 18 12H 50 32H 82 52H 114 72H 19 13H 51 33H 83 53H 115 73H 20 14H 52 34H 84 54H 116 74H 21 15H 53 35H 85 55H 117 75H 22 16H 54 36H 86 56H 118 76H 23 17H 55 37H 87 57H 119 77H 24 18H 56 38H 88 58H 120 78H 25 19H 57 39H 89 59H 121 79H 26 1AH 58 3AH 90 5AH 122 7AH 27 1BH 59 3BH 91 5BH 123 7BH 28 1CH 60 3CH 92 5CH 124 7CH 29 1DH 61 3DH 93 5DH 125 7DH 30 1EH 62 3EH 94 5EH 126 7EH 31 1FH 63 3FH 95 5FH 127 7FH

9 09H 00001001B

10 0AH 00001010B

11 0BH 00001011B

12 0CH 00001100B

13 0DH 00001101B

14 0EH 00001110B

15 0FH 00001111B

16 10H 00010000B

: :

125 7DH 01111101B

126 7EH 01111110B

127 7FH 01111111B

Decimal Hexadecimal Binary

Page 46 of the Casio CDP-200R user manual — MA0812-A
Page 46 · click to enlarge
Page 46

CASIO COMPUTER CO.,LTD.

6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan

MA0812-A

Ask about the Casio CDP-200R

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Casio CDP-200R

Be the first to ask — other owners or our team will answer.

Original document

Casio CDP-200R manual PDF

46 pages·338 KB·Music Mixer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…