Instruction/ maintenance manual of the product pm420 Carver
Go to page of 20
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
An important point after buying a device Carver pm420 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Carver pm420 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Carver pm420 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Carver pm420 you will learn all the available features of the product, as well as information on its operation. The information that you get Carver pm420 will certainly help you make a decision on the purchase.
If you already are a holder of Carver pm420, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Carver pm420.
However, one of the most important roles played by the user manual is to help in solving problems with Carver pm420. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Carver pm420 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center