Instruction/ maintenance manual of the product XRD9829REF Canon
Go to page of 24
EXAR Corporation, 48720 Kato Road, Fremont, CA 94538 • (510) 668-7000 • FAX (510) 668-7017 July 1998-2 XRD9829REF USER MANU AL CIS 30-BIT COLOR SINGLE LINE SCANNER.
XRD9829REF 2 Rev. 1.00 EVALUATION KIT PART LIST This kit contains the following: • XRD9829REF CIS 30-Bit Color Single Line Scanner • XRD9829REF User Manual • ScanIt 1.
XRD9829REF 3 Rev. 1.00 FLIP- FLOP CANON CWB-30216G 300DPI COLOR CIS XRD9829 FLIP- FLOP FIFO SRAM FIFO SRAM INTEL 486 Compatible PARALLEL PORT DB25 CONNECTOR CIS CONTROL SIGNALS DATA DATA DATA DATA DATA 5-BIT BUS NIBBLE XRD9829 CONTROL SIGNALS PARALLEL PORT CONTROL DC 1.
XRD9829REF 4 Rev. 1.00 OPERATIONAL PROCEDURE The routine listed below will first calibrate the photo response of the CIS using the XRD9829. After calibration, the XRD9829REF can be used to scan any color target to show CIS non-color corrected response.
XRD9829REF 5 Rev. 1.00 Parallel Port Configurations 9. Confirm the parallel port address as follows: a. Select the Start Menu, choose Settings, then choose Control Panel b. From the Control Panel window which pops up, double-click on System c . In the System Properties window, select Device Manager d.
XRD9829REF 6 Rev. 1.00 S 1 S 0 D 5 D 4 D 7 D 6 D 1 D 0 D 3 D 2 1 0 Figure 3. Dip Switches Set to Value 1100010000 to Reset the XRD9829.
XRD9829REF 7 Rev. 1.00 Control Registers Function D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0 Power-up (Register State S1/S0) (Note 1) Gain (00) G 5 G 4 G 3 G 2 G 1 G 0 X X 000000XX (MSB) (LSB) Offset O 7 O 6 O 5.
XRD9829REF 8 Rev. 1.00 12 . Select the Start Menu, choose Programs, then choose XRD9829REF icon 13 . A window will pop up as shown below. The upper window shows the Plot of Captured Data and the lower window shows the Histogram of data. Figure 3 shows the pop- up window when ScanIt is first s t a r t e d .
XRD9829REF 9 Rev. 1.00 15. Pick the black target out from the kit and put it on a flat area. Place the XRD9829REF on top of the black target with the CIS sensor facing downwards. From the CAPTURE menu select SNAP SHOT for a single line scan of the black target with the dip switches set to zero.
XRD9829REF 10 Rev. 1.00 Figure 6. Black Target Scan After Global Offset Adjust.
XRD9829REF 11 Rev. 1.00 RL VRT VRB VDD VIN0 - VIN2 XRD9829 C I S VIN0 VIN3 5V 100K 34K Figure 7. Simplified Block Diagram Showing Global Offset Adjustment by XRD9829 Using External Resistor Ladder 17. Set the dip switches to 0111000000 to select the internal offset DAC for fine offset adjustment.
XRD9829REF 12 Rev. 1.00 Figure 8. Black Target Scan After Global and Fine Adjust.
XRD9829REF 13 Rev. 1.00 RL VRT VRB VDD VIN0 XRD9829 C I S 8-Bit Offset DAC Figure 9. Simplified Block Diagram Showing Fine Offset Adjustment by XRD9829 18. Switch the black target to the enclosed white target. From the CAPTURE menu select SNAP SHOT for a single line scan of the white target.
XRD9829REF 14 Rev. 1.00 Figure 10. White Target Scan Without Gain Adjustment 19. Set the dip switches to 0000000100 to select the desired gain. Push the Serial Port button. From the CAPTURE menu select SNAP SHOT. The gain should move the output of the CIS to almost full scale.
XRD9829REF 15 Rev. 1.00 Figure 11. White Target Scan After Gain Adjustment.
XRD9829REF 16 Rev. 1.00 VIN0 XRD9829 C I S RL VRT VRB VDD PGA 6-Bit Gain Register Figure 12. Simplied Block Diagram Showing Gain Adjustment by XRD9829 20.
XRD9829REF 17 Rev. 1.00 Figure 13. Gray-scale Target Scan Important: 1. If at any time an unexpected result is shown or the demo system seems to not working, please pull the AC adapter out from the wall outlet to cycle power. Start the procedures again from Step 11.
XRD9829REF 18 Rev. 1.00 Schematics for XRD9829REF Page 1 of 3..
XRD9829REF 19 Rev. 1.00 Schematics for XRD9829REF Page 2 of 3..
XRD9829REF 20 Rev. 1.00 Schematics for XRD9829REF Page 3 of 3..
XRD9829REF 21 Rev. 1.00 Notes.
XRD9829REF 22 Rev. 1.00 Notes.
XRD9829REF 23 Rev. 1.00 Notes.
XRD9829REF 24 Rev. 1.00 NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability.
An important point after buying a device Canon XRD9829REF (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Canon XRD9829REF yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Canon XRD9829REF - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Canon XRD9829REF you will learn all the available features of the product, as well as information on its operation. The information that you get Canon XRD9829REF will certainly help you make a decision on the purchase.
If you already are a holder of Canon XRD9829REF, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Canon XRD9829REF.
However, one of the most important roles played by the user manual is to help in solving problems with Canon XRD9829REF. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Canon XRD9829REF along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center