Instruction/ maintenance manual of the product IMAGEFORMULA CR-190I M111021 Canon
Go to page of 31
♦ Please read this manual bef ore operating this scanner . Operation & Maintenance Guide.
1 ■ FCC REGULATIONS (For 120V model) Check Reader, Model M111021 This device complies with Par t 15 of the F CC Rules. Operation is subject to the following two co nditions: (1) This device may not cause harmful interf erence , and (2) this device must accept any interference received, including interfer en ce that may cause undesired operation.
2 ■ Disclaimers The information in this document is subject to change w ithout notice. CANON ELECTRONICS INC. MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, EIT HER EXPRESS OR IMPLIED, .
3 INTRODUCTION Thank you for purchasing t he C anon Check Reader CR-190i. Please read this manual thoroughly before using the machine in order to familiarize yourself with its capabi lities, and to make the most of its many functions. Manuals for the CR-190i The following manuals are provided wi th the CR-190i.
4 Table of Contents INTRODUCTION ............ .............. .............. .............. ............. 3 Manuals for the CR-190i ............................................................. 3 Symbols Used in This Manual ............................
5 Document Feeding and Scanning This chapter describes precauti ons regarding documents that can be handled on this scanner and scanning operations. Documents This section describes the types of documents that can be used and how to place them. CAUTION Treat the documents carefully.
6 Envelope You can also scan the envelope. Wh en using separation OFF mode, you can scan an envelope with thickness up to 0.02" (0.5 mm) or weight up to 111 lb bond (413 g/m 2 ). NOTE • Disab le the double feed detection function. (See “Using Ultrasonic Double Feed Detection,” on p.
7 Document Feeding and Scanning This section describes how to load and scan documents. CAUTION • Avoid wearing loose fitting clothin g, dangling jewelry, long ties, or long hair that could beco me entangled w ith moving parts, especially the rollers that feed pap er through the scanner.
8 5 Instruct scanning to start from the software ap plication. NOTE • Whe n Using the Accompanying Scanning Utility for CR-190i: There are three scanning method s as follows. Follow the each instruction. Scan 1 page Click [Scan Page] from the [File] menu.
9 Troubleshooting This chapter describes the problems that might occur in the CR-190i, and how to remedy them. When the Scanner Is Not Recognized The following causes and remedies describe why your computer may not recognize the scanner. Clearing Paper Jams If paper has jammed, open the Maintenance Cover and remove the jammed paper.
10 2 Press and hold the START Button. The jammed document is ejected into the Eject Pocket. If the above procedure does not clear the paper jam, perform the following to remove the jammed document. 3 Pull the Open Butto n, and pull the Front Maintenance Cover open to the right and left.
11 7 Close the Front Maint enance Cover in the order shown in the diagram belo w. Feeding Trouble If the document is not fed properly or the detection functions do not work properly, remedy the prob lem by checking the following conditions. Condition A paper jam has occurred.
12 When the Scanned Image Is Not Normal If there is a problem with the scanned image (the image is not sharp or stripes appear), one of the fo llowing conditions may be a probable cause. Check the following cond itions, and take the appropriate action.
13 Maintenance This chapter describes how to clean and maintain the scanner. Daily Cleaning To ensure high-quality image scanning, regularly clean your CR-1 90i as described below. CAUTION • Before you clean the scanner, turn OFF the scanner and computer, and disconnect the power co rd from the power outlet.
14 3 Wipe the f eed path w ith a firmly wrung cl oth, mois tened slightly with water or mild detergent. Then, wipe off with a clean, d ry cloth. 4 Close the Back M aintenance Cov er. 5 Close the Fron t Maintenance Cover in the orde r shown in the diagram below.
15 Cleaning the Scanning Glass and Rollers If stripes appear on scanned images or if dirt appears on scanned documents, clean the scanning gl ass and rollers. Clean the scanning glass and rollers regularly. 1 Remove the Top Cover. 2 Pull the Open Butto n, and pull the Front Maintenance Cover open to the right and left.
16 5 Spin the ro llers while wi ping them clean with a firmly wrung cloth damp ened with water or a mild dete rgent. There are 26 roller positions, as shown in the diag ram below. NOTE • Use cotton swabs to clean the rollers in locations that are too narrow for your fingers.
17 8 Close the Front Maint enance Cover in the order shown in the diagram belo w. 9 Replace the Roller Cover. 10 Carefully replace the Top Cover. IMPORTANT If paper jams and double feeds (two p apers being fed at the same time) still occur after cleaning the ro llers, the rollers may be worn.
18 Cleaning the Magnetic Heads If the magnetic heads are dirty, then MICR characters cannot be scanned correctly. Periodically, clean the magnetic heads with a commercially avail able audio head cleaner. 1 Pull the Open Butto n, and pull the Front Maintenance Cover open to the right and left.
19 Cleaning the Ink Jet Nozzles Ink that collects around the ink jet nozzles may stain your d ocuments or cause the text or bitmap to appears as scratched. Clea n the area around the ink jet nozzles periodicall y. Cleaning the ink jet nozzles is also efficient action when the printed text or bitmap becomes faint.
20 Cleaning with the Cleaning Cards (U.S.A. Only) If a black stripe appears on the back- side of scanned images or if dirt appears on the paper documents upon scanning or f or preventative measures, we recommend that you clean your C anon CR-Series scanner as needed with a cleaning ca rd.
21 Maintenance Make the following adjustment s to maintain scanning quality. Replacing the Ink Cartridge The ink cartridge needs to be replaced if the printed text becomes scratchy or faint even if you have cleaned the ink jet nozzle. The ink cartridge is not included with the scanner.
22 4 Place the ink cartridge shown in the diagram bel ow. CAUTION Do not touch the elec trical contact on the carriage. Doing so may cause a malfunction. NOTE Do not use more than one cartridge by rotation. If you do so, applications cannot check the ink level prec isely.
23 Replacing the ink disposal tank When the following conditions ap pear, you have to repla ce the ink disposal tank according to the following procedure. • When the ink cartridge is replaced. • When clumpy ink appears on the ink disposal tank as shown below.
24 4 Close the Ink Di sposal Tank Pocket. Replacing the Rollers When rollers are worn, paper jams and double feeds tend to occur. You can replace the rollers (Pickup Roller, Feed Roller, and Separation Roller) according to the following procedure. The exchange roller kit is not included with the scanner.
25 3 Open the Feed Supporter to the left. 4 Pinch the Separa tion Roller at the rim and the fixin g lever, and then remove it with pressing the Se paration OFF Mode Button. NOTE If the Separation Roller is not removed ea sily because of the fixing lever position, turn the Pickup Roll er in anticlockwise direction by hand.
26 5 Pinch the Feed Ro ller at the rim and the fixing leve r, and then remove it. 6 Pinch the Pickup Roller at the rim an d the fixing lever, and then remove it. NOTE If the Pickup Roller is not remove d easily because of the fixing lever position, turn the Pickup Roller by hand.
27 9 Attach the Separation Roller with push ing the Separation OFF Mode But ton. Align the no tch on the rol ler axis with the hole on the roll er. 10 Close the Feed Supp orter to the right. 11 Replace the Roll er Cover. 12 Carefully replace the Top Cover.
28 Adjusting the Separation Roller Gap If double feed should occur too often, adjust the Separation Roller gap according to the following procedure. 1 Slide the Adjustment Dial Cover to the left. 2 Adjust the Adjustment Dial . Turn the Adjustment Dial to the right 3 clicks.
29 Index A Adjusting the Print Position .......................................................... 22 Adjustment Dial ................................................... ........................ 28 Amount loaded .......................................
CANON ELECTRONICS INC. 1248, SHIMOKAGEMORI, CHI CHIBU-SHI, SAITAMA 369-1892 , JAPAN CANON U.S.A. INC. ONE CANON PLAZA, LAKE SUCCESS, N.Y. 110 42, U.S.A. CANON CANADA INC. 6390 DIXIE ROAD, MISSISSA UGA, ONTARIO L5T 1P7, CANADA CANON EUROPA N.V. BOVENKERKERWEG 59-61, P.
An important point after buying a device Canon IMAGEFORMULA CR-190I M111021 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Canon IMAGEFORMULA CR-190I M111021 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Canon IMAGEFORMULA CR-190I M111021 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Canon IMAGEFORMULA CR-190I M111021 you will learn all the available features of the product, as well as information on its operation. The information that you get Canon IMAGEFORMULA CR-190I M111021 will certainly help you make a decision on the purchase.
If you already are a holder of Canon IMAGEFORMULA CR-190I M111021, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Canon IMAGEFORMULA CR-190I M111021.
However, one of the most important roles played by the user manual is to help in solving problems with Canon IMAGEFORMULA CR-190I M111021. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Canon IMAGEFORMULA CR-190I M111021 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center