Instruction/ maintenance manual of the product Fiber Optic Media Converter Advantech
Go to page of 32
EKI-2741F 10/100/1000Bas e-T to SFP (mini-GBIC) Type Fiber Optic Media Converter EKI-2741SX 10/100/1000Bas e-T to 1000Base-SX SC Type Fiber Optic Media Converter EKI-2741LX 10/100/1000Bas e-T to 1000B.
EKI-2741F-SX-LX User Manual ii Copyright The documentation and the software i ncluded wi th this product are copyrighted 2007 by Advantech Co., Ltd. All rights ar e reserved. Advantech Co., Ltd. reserves the right to mak e improvements in the pro ducts describe d in this ma nual at any time without noti ce.
iii Product Warranty (2 years) Advantech warrants to you, the or igina l purchaser, that each of its products will be fre e from defects in materials and workmanshi p for two years from the date of purchase.
EKI-2741F-SX-LX User Manual iv Declaration of Conformity CE This product has passed the CE test for envir onmental spe cifications. Test conditions for passing included the equipment being operated within an indust rial enclosure.
v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC out let before clea ning. Use a damp cloth. Do not use liquid or spray detergents for clean ing.
EKI-2741F-SX-LX User Manual vi Safety Precaution - Static Electricity Follow these simple precautions to protect your self from harm and the produ cts from damage. 1. To avoid electrical shock, always di sconnec t the power from your PC chassis before you work on it.
vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ......................................................... 2 1.1.1 Fast Fiber Converters Module ................... 2 1.1.2 Dual Power Input .......
EKI-2741F-SX-LX User Manual viii.
1 Chapter1 Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER.
EKI-2741F-SX-LX User Manual 2 Chapter 1 Overview 1.1 Introduction The EKI-2741 is designed to convert Gi gabit Ethernet networks to Gigabit fiber networks by transparently converting Ethern e t signals to optic sig nals. The advantages of fiber optics are wide bandwidth, EMI immunity and long-distan ce transmission capability.
3 Chapter1 1.2 Features • Provides 1 x SFP (mini-GBIC) type connector (EKI-2741F) • Provides 1 x 1000Base-SX or 1000Base-LX SC type connector (E KI-2741SX/LX) • Provides 1 x 10/100/1000Mbps Ethe.
EKI-2741F-SX-LX User Manual 4 1.3 Specification Communications Standard IEEE 802.3, 802.3ab, 802.3u, 802.3x, 802.3z LAN 10/100/1000Base-TX, 1000Base -SX, 1000Base-LX Transmission Distance Multi-Mode F.
5 Chapter1 Environment Operating Temperature -10 ~ 60 ℃ (14~140 ℉ ) Wide temp. model: -40 ~ 75 ℃ (-40 ~ 167℉) Storage Temperature -40 ~ 85 ℃ (-40 ~ 185 ℉ ) Operating Humidity 5 ~ 95% (non-conde nsing) Storage Humidity 0 ~ 95% (non-condensi ng) Certifications Safety UL, 60950-1, CAN/CSA-C22.
EKI-2741F-SX-LX User Manual 6 1.4 Packing List • 1 x EKI-2741F or EKI-2741SX or EKI -2741LX Industrial Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User m a.
7 Chapter2 Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER.
EKI-2741F-SX-LX User Manual 8 Chapter 2 Installation In this chapter, you will be given an over view of the EKI-2741F/SX/LX hardware installation procedures.
9 Chapter2 2.2 DIP-Switch The DIP-Switch is used to config ure operation mode for LFP ( Link Fault Pass- Through ) and operation mode for UT P/Fiber port.
EKI-2741F-SX-LX User Manual 10 2.3 Dimensions (units: mm) Figure 2.1: Front View of EKI-2741 series.
11 Ch apter2 Figure 2.2: Side View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 12 Figure 2.3: Rear View of EKI-2741 series.
13 Ch apter2 The terminal block of power & relay is located o n the top side. Please refer to page 16 for pin assignment. Figure 2.4: Top View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 14 2.4 Mounting The EKI-2741F/SX/LX support two mounting methods: DIN-rail & Wall. 2.4.1 Wall mounting EKI-2741F/SX/LX can be wall-mounted by using the included mou nting kit. Then, hang on the EKI-2741F/SX/LX to the nails on the wall.
15 Ch apter2 2.4.2 DIN-rail Mounting You can also mount EKI-2741F/SX/LX on a standard DIN-rail by below steps. The DIN-rail kit is screwed on the industrial sw itch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.
EKI-2741F-SX-LX User Manual 16 Then, let the device down straight to slide over the rail smoothly. See Figure 2.7 Figure 2.7: Installation to DIN-rail Step 2.
17 Ch apter2 2.5 Network Connection • Twisted-pair segment can use unshielded tw isted pair (UTP) or shi elded twisted pair (STP) cabling. The cable between the lin k pa rtner (switch, hub, workstation, etc.) and the converter, mu st be less than 100 meters (328 ft.
EKI-2741F-SX-LX User Manual 18 Second, insert the fiber cable of LC conn ector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the trans ceiver, please follow the step s shown below: First, press the upper side of the LC con nector fr om the transceiver and pull it out to release.
19 Ch apter2 Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module.
EKI-2741F-SX-LX User Manual 20 2.6 Power Connection The EKI-2741F/SX/LX support dual +12 ~ 48 V DC power inputs a nd power-fail relay output. Figure 2.13: Pin Assignment of the Power Connecto r You can connect an alarm i ndicator, buzzer or other signalin g equipment through the relay output.
21 Ch apter2 Troubleshooting CHAPTER.
EKI-2741F-SX-LX User Manual 22 Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/ada pter (+12~48 V DC ), please don’t use the power adaptor with DC o utput voltage higher than 48V, or it will burn this converter down.
23 Ch apter2 Pin Assignment & Wiring APPENDIX.
EKI-2741F-SX-LX User Manual 24 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.
An important point after buying a device Advantech Fiber Optic Media Converter (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Advantech Fiber Optic Media Converter yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Advantech Fiber Optic Media Converter - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Advantech Fiber Optic Media Converter you will learn all the available features of the product, as well as information on its operation. The information that you get Advantech Fiber Optic Media Converter will certainly help you make a decision on the purchase.
If you already are a holder of Advantech Fiber Optic Media Converter, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Advantech Fiber Optic Media Converter.
However, one of the most important roles played by the user manual is to help in solving problems with Advantech Fiber Optic Media Converter. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Advantech Fiber Optic Media Converter along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center