Instruction/ maintenance manual of the product ConversionCalc Plus Calculated Industries
Go to page of 44
Model 8030 F AS T . ACCU RATE. RELIABLE. C O NVERSION C A L C P LUS ™ U L TIMA TE P ROFESSIONAL C ONVERSION C ALCULA TOR PRG8030E-A.indd 1 8/21/2012 11:39:49 AM.
P ocket R efeRence G uide — 3 CONVERSIONCALC PLUS™ The ConversionCalc Plus ™ is an easy-to -use and power ful handheld ca lc ulat or th at pr ovid es m ore t ha n 50 0 conversion combinations using 70 buil t- in St an dar d, Me tr ic an d oth er unit s of me asu re.
P ocket R efeRence G uide — 3 The C onve rsionCalc Plus ™ is the professional choice for: • Hea lth C ar e Prof es sio nal s • Sc ient is ts • Phar ma ci sts • Nut r iti oni st s • Lab T.
P ocket R efeRence G uide — 5 T ABLE OF CONTENTS GETTING ST ARTED 6 Key Denitions 6 Bas ic Funct io n Keys 6 Misce llaneous F unct ion Ke ys 7 Co nvers io n Funct io n Keys 9 Preference Settings .
P ocket R efeRence G uide — 5 V olume Conv ersion 25 Weigh t Conve rsion 28 Weigh t / V olume Con version 29 T emperature Conversion 31 Flow R ate C onver si on 31 Pressure Conv er sion 32 V elocit .
P ocket R efeRence G uide — 7 GETTING ST ARTED Y ou may want to p rac ti c e get t ing a fee l for yo ur c alc ul ator keys by rea ding t hr oug h the key de ni tio ns and l ear ni ng how t o ente r dat a, how to st ore va lue s, etc ., befo re pro c eed ing t o the exa mpl es.
P ocket R efeRence G uide — 7 (cont’d) / Fr act io n Ba r — Used t o enter f rac ti on s. Fract io ns ca n be ente red as pr op er ( 1/2, 1/8, 1/ 16) o r impr op er (3/2 , 9/8). If the de no mina tor (b ot tom) is not entered , the calculator ’ s fr act io nal a cc ur acy s et tin g is automatically used.
P ocket R efeRence G uide — 9 (cont’d) SB Squ ar e Ro ot ( ! ) — Cal cul ate s the Squ are Ro ot of th e numb er in t he di sp lay . S= Pap e rl es s Tape ( T ap e) — Ac ce ss es th e Paper l es s T ape M ode, w hic h kee ps tra ck of yo ur pa st 20 e ntr i es.
P ocket R efeRence G uide — 9 (cont’d) S. T ota l Co st (C os t) — Cal cul ate s tota l c ost b ase d on ent r y o f per u nit c os t. S% x 2 — Squ are s the va lue o n t h e d i s p l a y. S/ Exp onential Notati on x(1 0 y ) — Enter s expo ne nti al not ati on va lue s.
P ocket R efeRence G uide — 11 Centimeter c Millimete r M Kilometer k Miles N Acre S5 Hectare S4 Boa rd Fe et (B d - Ft) S0 Acr e Fee t (Ac r e - Ft) S6 Gallon G Flui d O unc e F Quar t Tm Pint Tc C.
P ocket R efeRence G uide — 11 (cont’d) Weight Keys UNIT KEY To n s t Pou nd s p Dr y Ou nc e d Kilogram K Grams g Milligram (mg ) Td Microgram (mc g) TK Nanogram (ng) Tg Me t ri c T on s (met ton.
P ocket R efeRence G uide — 13 Me te r s p er Second (m/s e c) Sc Millimete rs per Second (mm /s ec) SM Kilometers pe r Ho ur (k m / h) Sk Flow Rate Keys UNIT KEY Ga ll on s pe r Minute (g pm ) SG O.
P ocket R efeRence G uide — 13 T orque Keys UNIT KEY Inch- Pounds (i n - l bs) S7 Foot - Pounds (f t - l bs) S8 Newton - Meter s (N - m) S9 T emperature Keys UNIT KEY Celsius (°C) S2 Fahre nheit (.
P ocket R efeRence G uide — 15 PREFERENCE SETTINGS Pres s T , the n / to acc e ss t he Preferences menu . Continue pressing / to toggle through different Preferences. Press + o r - ke ys to tog gl e bet we en op tio ns of t he different Preferences.
P ocket R efeRence G uide — 15 Thi rd pr es s of / : (Volume An swer Format) VOL S td . + VOL 0. CU Y D + VOL 0. CU FE ET + VOL 0. CU M + (repeats options ) VOL St d. Four t h pr es s of / : (Exponential Mo de) E XP O n + E XP O FF + (repeats options ) E XP O n Fif t h pre ss o f / : (Metri c Rounding) ME TR 0.
P ocket R efeRence G uide — 17 CALCULA TING PERCENT AGES The % key c an be u sed f or ndin g a given p er ce nt of a num be r or fo r wor ki ng ad d - on, d isc o unt or d ivi si on per ce nt age c al cu lat io ns. It c a n be use d wit h any t yp e of num be r , in any dime nsi on (fe et, in ch, m ill imet er , etc .
P ocket R efeRence G uide — 17 USING EXPONENTIAL NOT A TION Y o ur c alc ula tor i s defa ulte d to have expo nent ia l not ati on s et to “on.” Ther efo re, any inte ge r valu e excee din g seven di git s wi ll dis pl ay in exp one nti al fo rm at.
P ocket R efeRence G uide — 19 (cont’d) Enter 2 ,3 5 6 and c hang e to exponential notation: KEYST ROKE D I S P L AY 2356= 2356. / 2.35600 03 Enter 0 .0 0 0 5 6 and c han ge to exponential notation: .00056= 0. 00056 / 5.60000 - 04 MEMOR Y OPERA TION Whenever the P key is pr es se d, the d isp layed val ue wi ll b e add ed to the M e mor y .
P ocket R efeRence G uide — 19 (cont’d) Whe n M emo r y i s rec al le d ( rP ), co nse cu ti ve pre ss es of P w ill disp lay th e c alc ula ted Avera ge an d tot al C o unt o f th e ac c umu lat ed va lu es . Using M+ KEYST ROKE D I S P L AY 45P M+ 4 5.
P ocket R efeRence G uide — 21 Y ou can replace a value in one of these Memory registers by storing a new value in place of the stored value. — Sto re sin gl e value i n M 0 — Cle ar M 0 — Rec all M 0 Sto re 212.5 into M 0 , r eca ll th e valu e and then clear the v alue.
P ocket R efeRence G uide — 21 KEYST ROKE D I S P L AY O O 0. 1 5 L + 15 . mL 2 5 L + 40 . mL 4 5 L = 85 . mL r = 85 . mL + 15 . mL + 25. mL + 45 . mL = 85 .
P ocket R efeRence G uide — 23 ENTERING DIMENSIONS AND UNITS When entering feet-inch dimensional value s, you m ust e nter t he la rge st dime nsi on r st — feet b efo re inc he s, inc he s bef ore f ra ct io ns.
P ocket R efeRence G uide — 23 (cont’d) 5 feet 1-1 /2 i nch 5f1i1/2 10 y a r ds 10y 1 7. 5 m e t e r s 17 .5m Square and Cubic Dimensions For square dimensions, enter the value and press the unit key twice. For cubic dimensions, press the unit key three times.
P ocket R efeRence G uide — 25 375L+ 385L+ 65L= 375 . mL 760 . mL 825 . mL 2. C onver t to oth er uni ts: Tl ( microliters ) 8250 0 0. mc L f (c u b i c f e e t) 0 . 0 2 913 5 CU FE ET i (cubic in ches) 50.34459 CU I NC H F ( ui d oun ces) 27 .8 9 65 7 F- OZ G (gallons) 0.
P ocket R efeRence G uide — 25 (cont’d) c 5655.31 CM M 5 6 5 5 3 .1 MM k 0.05 6 55 3 k M N 0.03 51 4 MILE Area Conversion Enter 125 squar e me ters a nd c onver t to oth er un its of a rea: KEYST ROKE D I S P L AY OO 0. 125mm 12 5 SQ M y 1 49.4988 SQ Y D f 13 4 5 .
P ocket R efeRence G uide — 27 m 2 .1 2 3 7 6 3 CU M S0 (Board Feet) 90 0. BDFT S6 (Acre Feet) 0.001722 ACF T Enter 15 lit ers an d co nver t t o oth er uni ts of vo lum e: KEYST ROKE D I S P L AY OO 0. 1 5 l 1 5 L F ( ui d oun ces) 507 . 2103 F- OZ Tm (qu a r t) 1 5.
P ocket R efeRence G uide — 27 25Ti (d r a m s) 25 DRAM L (milliliters ) 9 2 . 417 2 8 mL Tl ( microliters) 924 17 .2 8 mcL TL ( nanoliters ) 9 . 2 417 3 07 nL Ty (drops o r gt ts) 1 386.259 GTT S Adj ust t he def aul t to 20 d ro ps pe r cub ic c enti me ter .
P ocket R efeRence G uide — 29 Weight Conversion Enter 1,2 0 0 pou nds an d co nver t t o othe r uni ts of we igh t: KEYST ROKE D I S P L AY OO 0. 1200p 1 200 LB t 0. 6 To n S1 (metric tons ) 0. 54431 1 ME T To n d 1 920 0. D- OZ K 54 4.3 10 8 k G g 5443 10 .
P ocket R efeRence G uide — 29 Weight/V olume Conversions The C onve rsionCalc Plus can co nver t b et we en Weig ht and Volum e. T o re c all Wei ght p er Volume f ac tor press T% . Co nti nue pr es sin g % to dis play as p oun ds, g rai ns, m etr ic tons, kilograms, grams, mill igrams or tons .
P ocket R efeRence G uide — 31 T o c han ge t he Weig ht pe r Volume fac tor, enter th e value, t he n pre ss T% . Th e r st p res s wi ll ent er th e Weight a s the c a lc ulato r ’s cur ren t set ti ng. T o ch ang e th e Weight p er Volume fa cto r , c ont inu e to pr es s the % key to cyc le t hro ugh t he f act or s show n ab ove.
P ocket R efeRence G uide — 31 (cont’d) *Continue pre ssing % unt il L B Per C U FEET is shown. 6TM (Cup ) 6 CUP p 2. 8 52 40 9 LB Not e: To retur n we ig ht /vo lu me f ac tor t o def aul t se t ti ng of 6 2 .4279 6 p ou nds p er cu bi c foo t, p er for m a C lea r Al l by pr ess i ng S * .
P ocket R efeRence G uide — 33 Sl (li ters p er second) 0.0 82017 L/S SL (mill il ite rs p er second) 82 . 01 72 6 m L /S Pressure Conversion Enter 3 4 5 ki lo pas cal s and c onver t to other units of pressure : KEYST ROKE D I S P L AY OO 0. 345 SK (kilopascals) 34 5 K PA Co nver t to o ther u ni ts of pr ess ur e: Sg (megapascals ) 0.
P ocket R efeRence G uide — 33 (cont’d) 150Sk (kilometers per hour) 1 5 0 KM/H SN (mi l es per hour) 93.2056 8 MPH Sm (me te r s per minut e) 2500. M/M Sc (me te r s per second) 4 1.66667 M/S SM ( millimeters per second) 4 1666.67 MM/S Sy (feet per minute ) 8202.
P ocket R efeRence G uide — 35 Energy Conversion Enter 2 25 ki lo ca lor ie s and c onver t to Jou les a nd B ri tis h the rm al un its: KEYST ROKE D I S P L AY OO 0. 225T6 (kilocalories) 225 KCA L Co nver t to o ther u ni ts of en erg y: T4 ( Joules) 941 40 0.
P ocket R efeRence G uide — 35 APPENDIX DEF AUL T SETTINGS Af te r a Cle ar A ll ( S* ), your ca lc ulato r wi ll ret ur n to th e fol low in g settings: STOR ED VALUES DEF AUL T V ALUE Weight p er Vo l u m e 62 . 42 79 6 LB/ CU F T Dro ps (gt t s ) p er cubic centimeter 15 .
P ocket R efeRence G uide — 37 A UTO SHUT -OFF Y o ur c alc ula tor w ill s hut it se lf of f af ter abo ut 8 -1 2 mi nute s of no n- u se. ACCURA CY/ERRORS Accuracy/Display Capacity Y o ur c alc ula tor h as a t wel ve dig it disp lay. This is ma de up of e ig ht dig its (norm al di spl ay ) a nd fo ur fr ac ti ona l digi ts .
P ocket R efeRence G uide — 37 Auto-Range If an “ove r ow ” i s cr eate d be ca use of a c alc ula tio n wi th sm all u nit s th at are o ut of th e st and ard d igi t ran ge of th e disp lay , t he an swer w ill b e auto mat ic all y expr es sed i n the n ex t lar ger u nit s (ins tead o f show in g “ O FLO ” ) – e.
P ocket R efeRence G uide — 39 RESET If you r ca lc ulat or sh oul d ever “ lo ck up, ” p res s Res et – a sma ll ho le loc at ed be low t he o key – to per for m a to tal r es et.
P ocket R efeRence G uide — 39 (cont’d) W ARRANTY Cal cul ate d Indu str i es ( “C I” ) war ra nts thi s pro du ct ag ain st def ec ts in mate ri als a nd wo rk man shi p for a per i od of o ne (1 ) year f ro m the d ate of original consumer purchase in the U.
P ocket R efeRence G uide — 41 A rep aire d or r epl ac em ent pr od uct assumes the remaining warrant y of th e or igi nal p ro duc t or 9 0 d ays, whichever is longer .
P ocket R efeRence G uide — 41 Disclaimer CI M A KES N O WAR R A N T Y O R REPR ESE NT A TI ON , EITH ER E XPR ES S OR I M PLIED, WI TH RES PECT TO THE PR OD UCT ’ S QUA LIT Y , PERFO RM A N CE, MER CH A NT A BI LIT Y , OR FIT N ESS FOR A PARTI CU L A R PU RP OS E.
P ocket R efeRence G uide — 43 Som e st ates d o not a llo w the exc lusi on or limi tation of implied warranties or liab ili t y for i nc ide nt al or c o nse que ntia l dama ge s, so t he ab ove lim ita ti on or exclus io n may not ap pl y to you.
P ocket R efeRence G uide — 43 4840 Hytech Drive Carson City , NV 89706 U.S.A. 1-775-885-4900 Fax: 1-775-885-4949 E-mail: info@calculated.com www .calculated.
Desi gn ed in the United St at es of A mer ica. PR G 8030 E- A Printed in China PRG8030E-A.indd 44 8/21/2012 11:39:53 AM.
An important point after buying a device Calculated Industries ConversionCalc Plus (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Calculated Industries ConversionCalc Plus yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Calculated Industries ConversionCalc Plus - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Calculated Industries ConversionCalc Plus you will learn all the available features of the product, as well as information on its operation. The information that you get Calculated Industries ConversionCalc Plus will certainly help you make a decision on the purchase.
If you already are a holder of Calculated Industries ConversionCalc Plus, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Calculated Industries ConversionCalc Plus.
However, one of the most important roles played by the user manual is to help in solving problems with Calculated Industries ConversionCalc Plus. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Calculated Industries ConversionCalc Plus along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center